  • 7/25/2019 Alarms and Error Codes 88 Series

    1/40

    AGRICULTURAL EQUIPMENT SERVICE TRAINING

    88SERIESMID RANGE

    AXIAL-FLOW COMBINE

    SECTION 57ALARM,ABORT,ICON &ERRORCODE LISTING

    Form 5162 rev 4/1/2008

  • 7/25/2019 Alarms and Error Codes 88 Series

    2/40

    CNH America LLC

    700 STATE STREET

    RACINE, WI 53404

    U.S.A.

    2008 CNH America LLC

    All Rights Reserved

    Printed in U.S.A.

  • 7/25/2019 Alarms and Error Codes 88 Series

    3/40

    TABLE OF CONTENTS

    SUBJECT PAGE

    Alarm, Abort and Error Code Information-----------------------------------------------------------7

    Abort Code Listing ----------------------------------------------------------------------------------------8CXCM -----------------------------------------------------------------------------------------------------8

    A Post ---------------------------------------------------------------------------------------------------9

    Alarm Code Listing -------------------------------------------------------------------------------------10

    A Post Digital Display ----------------------------------------------------------------------------10

    CXCM ---------------------------------------------------------------------------------------------------11

    CXCM Error Listing -------------------------------------------------------------------------------------13

    A Post Error Listing -----------------------------------------------------------------------------------29

    Engine Error Listing ------------------------------------------------------------------------------------34

  • 7/25/2019 Alarms and Error Codes 88 Series

    4/40

    CODE LISTING

    57-4

  • 7/25/2019 Alarms and Error Codes 88 Series

    5/40

    CODE LISTING

    Keep an eye out for symbols, which will alert you to special information.

    Wait a Minute This symbol will preface a frequently asked question.

    REMEM ER:

    IMPORT NT

    : This symbol will preface a tip that you should definitely not

    ignore.

    57-5

  • 7/25/2019 Alarms and Error Codes 88 Series

    6/40

    CODE LISTING

    57-6

  • 7/25/2019 Alarms and Error Codes 88 Series

    7/40

    CODE LISTING

    ALARM,ABORT AND ERROR CODE INFORMATION

    Abort and Alarms have an A prefix. All error codes have an E prefix. The codes for 88 series

    machines are broken down by controllers as follows:

    SPN APOST CXCM ENGINE

    Abort A-025 A-049 A-000 A-024 None

    Alarm A-100 A-199 A-200 A-299 None

    Error E128-183 E000-127 E184-255

    Alarms and Abort codes only have one number such as A 000.

    Error codes are written in two parts separated by a decimal point.

    Example: E 7.4

    7 = Area of concert, this is the Specific Product Numerator (SPN) number.4 = Type of failure, this is the Failure Mode Indicator (FMI) number

    The main FMI numbers will be

    3 The circuit is being supplied a voltage higher then the controllers regulator

    (shorted to a high side voltage)

    4 The circuit is being grounded and the voltage is below 0.5V (shorted to a low

    side)

    5 The supply voltage is at the controllers regulated voltage level (open circuit)

    FMI# FMI FMI# FMI

    0 Valid above normal 9 Abnormal update rate

    1 Valid below normal 10 Abnormal rate of change

    2 Data incorrect 11 Unidentified Failure Code

    3 Shorted to high source 12 Bad intelligent device

    4 Shorted to low source 13 Needs Calibration

    5 Line disconnected 14 Special Instructions

    6 Short circuit 15-18 Data Invalid

    7 Mechanical out of range 19 Received network error

    8 Abnormal pulse rate 20-31 Not Used at this time

    57-7

  • 7/25/2019 Alarms and Error Codes 88 Series

    8/40

    CODE LISTING

    ABORT CODE LISTING

    CXCM

    ABORT # DESCRIPTION DISPLAY ICON SECTION

    A 000 Operator Stop

    STOP

    A 001 Feeder Angle

    Sensor Value Is

    Invalid Or Not

    Changing

    A 002 Engine Is Not

    Running 0

    A 003 Feeder is

    Engaged 0

    A 004 Header Tilt Sensor

    Value Is Invalid Or

    Not Changing

    A 005 Ground Speed Is

    Not Zero 0

    A 006 Upper Sieve

    Sensor Value Is

    Invalid

    A 007 Lower Sieve

    Sensor Value Is

    Invalid

    A 008 Stripper Plate

    Sensor Value Is

    Invalid

    A 009 Reel Not Moving

    57-8

  • 7/25/2019 Alarms and Error Codes 88 Series

    9/40

    CODE LISTING

    ABORT CODE LISTING

    APOST

    ABORT # DESCRIPTION RCDSECTION

    A 025 Concave Sensor

    Value is Invalid 0.0

    A 026 Tailings Sensor

    Value is Invalid 0

    A 027 Spreader Position

    Sensor Value is

    Invalid

    57-9

  • 7/25/2019 Alarms and Error Codes 88 Series

    10/40

    CODE LISTING

    ALARM CODE LISTING

    APOST DIGITAL DISPLAY

    ALARM # DESCRIPTION TRIGGERSYSTEM(S)

    CONTROLLED

    ACTION TAKEN

    ON CONTROLLED

    SYSTEM(S)

    A 100 Decrease Engine

    Speed

    Engine Speed > 1800

    RPM when Separator

    Enabled

    Separator Engagement

    Disabled

    A 101 FEEDER_SHUTD

    OWN

    See Audible Alarms and

    Indicators section: Intake

    Manifold Temp High,

    Mechanical Engine

    Feeder Disengaged

    A 102 Not Used

    A 103 Power Boost

    Disabled

    Power Boost Enable

    Command is enabled

    and Power Boost Active

    Status goes from Active

    to Inactive

    None N/A

    A Post Alarm Graphics

    These graphics will appear on the A post when the associated Alarm is active.

    ALARM # RCDSECTION ALARM # RCDSECTION

    A 100

    1800

    A 102 Not Used

    A 101

    STOP

    A 103

    +%

    57-10

  • 7/25/2019 Alarms and Error Codes 88 Series

    11/40

    CODE LISTING

    ALARM CODE LISTING

    CXCM

    ALARM

    #

    DESCRIPTION RCDSECTION

    A 200 Calibrate Ground Height Sensors

    2 SEC

    2

    1

    A 201 Auto Height Disabled

    A

    A 202 Auto Tilt Disabled

    A

    A 203 Spare

    A 204 Rear Ladder Down

    A 205 Spare

    A 206 Upper Sieve Position Setting

    NN

    A 207 Lower Sieve Position Setting

    NN

    57-11

  • 7/25/2019 Alarms and Error Codes 88 Series

    12/40

    CODE LISTING

    57-12

  • 7/25/2019 Alarms and Error Codes 88 Series

    13/40

    ERROR LISTING

    ERROR LISTING

    CXCMERROR LISTING

    CXCM Controller

    SPN DescriptionPriorit

    yDetected Faults

    I/O Name / Pin

    Out / Diagnostic

    Function

    A-Post 2

    Indicator /

    Troubleshoot

    Menu

    A-P

    0000 SpareAN01 /

    CN1-B1 /

    0001

    Feeder

    Position Angle

    Sensor

    LowFMI 3 - Voltage > 4.9 volts

    FMI 4 - Voltage < 0.05 volts

    AN02 /

    CN1-B2 /

    V

    Header /

    Header

    0002

    Header Lift

    Pressure

    Sensor

    LowFMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    AN03 /

    CN1-B3 /

    V

    Header /

    Header

    0003

    Right

    Height/Tilt

    Sensor

    LowFMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    AN04 /

    CN1-B4 /

    V

    Header /

    Header-

    0004Right Center

    Height SensorLow

    FMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    AN05 /

    CN1-B5 /

    V

    Header /

    Header-

    0005Left Center

    Height SensorLow

    FMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    AN06 /

    CN1-B6 /

    V

    Header /

    Header-

    0006 SpareAN07 /

    CN1-B7 /

    57-13

  • 7/25/2019 Alarms and Error Codes 88 Series

    14/40

    ERROR LISTING

    CXCM ControllerA-Post 2

    I/O Name / PinPriorit Indicator / A-P

    SPN Description Detected Faults Out / Diagnosticy Troubleshoot

    Function

    Menu

    0007Left Height/Tilt

    SensorLow

    FMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    AN08 /

    CN1-B8 /

    V

    Header /

    Header

    0008Rear Ladder

    Down SensorMedium

    FMI 3 - Voltage > 4.85 volts

    FMI 4 - Voltage < 0.82 volts

    AN09 /

    CN1-B9 /

    V

    Combine /

    Combine

    0009 SpareAN10 /

    CN1-B10 /

    0010 SpareAN11 /

    CN1-B11 /

    0011 SpareAN12 /

    CN1-B12 /

    0012 SpareAN13 /

    CN1-B13 /

    0013 Bypass FullNone: valid range is 0 to

    Vbatt

    AN14 /

    CN1-B14 /

    0014MFHIN7

    Switch

    None: valid range is 0 to

    Vbatt

    AN15 /

    CN3-A18 /

    0015 SpareAN16 /

    CN3-A19 /

    0016 SpareAN17 /

    CN3-A26 /

    0017 SpareAN18 /

    CN3-A1 /

    57-14

  • 7/25/2019 Alarms and Error Codes 88 Series

    15/40

    ERROR LISTING

    CXCM Controller

    A-Post 2I/O Name / Pin

    Priorit Indicator / A-PSPN Description Detected Faults Out / Diagnostic

    y Troubleshoot Function

    Menu

    0018 SpareAN19 /

    CN3-A2 /

    0019Raise Rate Pot

    (HI)Low FMI 4 - Voltage < 4.0 volts

    AN20 /

    CN3-A3 /

    V

    Header /

    Header

    (+

    0020 Raise Rate Pot LowFMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    AN21 /

    CN3-A4 /

    V

    Header /

    Header

    0021Raise Rate Pot

    (LO)Low FMI 3 - Voltage > 1.0 volts

    AN22 /CN3-A5

    V

    Header /

    Header(

    0022Lower Rate

    PotLow

    FMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    AN23 /

    CN3-A6 /

    V

    Header /

    Header

    0023Lower Rate

    Pot (LO)Low FMI 3 - Voltage > 1.0 volts

    AN24 /

    CN3-A7 /

    V

    Header /

    Header

    (

    0024Reel Speed

    PotLow

    FMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    AN25 /CN3-A8 /

    V

    Header /

    Reel

    0025Reel Speed

    Pot (LO)Low FMI 3 - Voltage > 1.0 volts

    AN26 /

    CN3-A9 /

    V

    Header /

    Reel

    (

    57-15

  • 7/25/2019 Alarms and Error Codes 88 Series

    16/40

  • 7/25/2019 Alarms and Error Codes 88 Series

    17/40

    ERROR LISTING

    CXCM Controller

    A-Post 2I/O Name / Pin

    Priorit Indicator / A-PSPN Description Detected Faults Out / Diagnostic

    y Troubleshoot Function

    Menu

    0033Reel Speed

    Pot (HI)Low FMI 4 - Voltage < 4.0 volts

    AN34 /

    CN4-A16 /

    V

    Header /

    Reel

    (+

    0034Header Type

    SensorLow

    FMI 2 - If Header Type Input

    changes while separator is

    on.

    FMI 3 - Voltage > 4.72 volts

    AN35 /

    CN4-A20 /

    V

    Header /

    Header

    0035

    Upper Sieve

    Position

    Sensor

    Low

    FMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    FMI 13 Needs calibration

    AN36 /

    CN4-A25 /

    V

    Combine /

    Sieve &

    Unloader

    0036

    Lower Sieve

    Position

    Sensor

    Low

    FMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    FMI 13 Needs calibration

    AN37 /

    CN4-A8 /

    V

    Combine /

    Sieve &

    Unloader

    0037

    Air/Air

    Temperature

    Sensor(mecha

    nical engine

    only)

    LowFMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.1 volts

    AN38 /

    CN4-A1 /

    V

    Engine /

    Engine

    0038Unloader Tube

    In Sensor

    None: valid range is 0 to

    Vbatt

    AN39 /

    CN4-A21 /

    V

    Not Applicable/

    Sieve &

    Unloader

    0039 SpareAN40 /

    CN4-A15 /

    57-17

  • 7/25/2019 Alarms and Error Codes 88 Series

    18/40

    ERROR LISTING

    CXCM ControllerA-Post 2

    I/O Name / PinPriorit Indicator / A-P

    SPN Description Detected Faults Out / Diagnosticy Troubleshoot

    Function

    Menu

    0040Min Reel Pot

    (HI)Low FMI 4 - Voltage < 4.0 volts

    AN41 /

    CN4-A9 /

    V

    Header /

    Reel

    (+

    0041

    Air/Air

    Temperature

    Supply(mecha

    nical engine

    only)

    Low FMI 4 - Voltage < 0.2 volts

    AN42 /

    CN4-A22 /

    V

    Engine /

    Engine

    (+

    0042 12VF HighSide Supply

    Medium FMI 3 - Voltage > 18.0 voltsFMI 4 - Voltage < 7.0 volts

    12VF /

    CN1-A1,A2, A3 /

    V

    Combine /Voltage

    1

    004312VD High

    Side SupplyMedium

    FMI 3 - Voltage > 18.0 volts

    FMI 4 - Voltage < 7.0 volts

    12VD /

    CN1-A8 /

    V

    Combine /

    Voltage

    1

    004412VH High

    Side SupplyMedium

    FMI 3 - Voltage > 18.0 volts

    FMI 4 - Voltage < 7.0 volts

    12VH /

    CN1-A20 /

    V

    Combine /

    Voltage

    1

    004512VT High

    Side SupplyMedium

    FMI 3 - Voltage > 18.0 volts

    FMI 4 - Voltage < 7.0 volts

    12VT /CN3-B25,

    CN3-B34 /

    V

    Combine /

    Voltage

    1

    57-18

  • 7/25/2019 Alarms and Error Codes 88 Series

    19/40

    ERROR LISTING

    CXCM Controller

    A-Post 2I/O Name / Pin

    Priorit Indicator / A-PSPN Description Detected Faults Out / Diagnostic

    y Troubleshoot Function

    Menu

    00465V Reference

    SupplyMedium

    FMI 3 - Voltage > 5.5 volts

    FMI 4 - Voltage < 4.5 volts

    5VREF_MON /

    CN1-B16,

    CN1-B17 /

    V

    Combine /

    Voltage

    5

    0047Moisture

    Sensor PlusLow

    FMI 3 - Voltage > 9.39 volts

    FMI 4 - Voltage < 0.195 volts

    AN_FQ7 /

    CN3-B21 /If fault detected,

    0048Moisture

    Sensor MinusLow

    FMI 3 - Voltage > 9.39 volts

    FMI 4 - Voltage < 0.195 volts

    AN_FQ7 /

    CN3-B22 /If fault detected,

    0049Reel Drive

    Solenoid LowFMI 11 - High Side Smart

    Driver Error

    HSD_1 /

    CN1-A9 /S

    Header /

    Reel

    0050Sieve Select

    RelayLow

    FMI 11 - High Side Smart

    Driver Error

    HSD_2 /

    CN1-A10 /

    S

    Combine /

    Sieve &

    Unloader

    0051

    Unloader

    Swing Out

    Solenoid

    Low

    FMI 3 - Shorted to 12v

    FMI 11 - High Side Smart

    Driver Error

    HSD_3 /

    CN1-A4 /

    S

    Combine /

    Sieve &

    Unloader

    0052

    Unloader

    Swing InSolenoid

    Low FMI 11 - High Side SmartDriver Error

    HSD_4 /

    CN1-A11 /S

    Combine /

    Sieve &Unloader

    0053Header Raise

    SolenoidLow

    FMI 11 - High Side Smart

    Driver Error

    HSD_5 /

    CN1-A5 /

    S

    Header /

    Header

    57-19

  • 7/25/2019 Alarms and Error Codes 88 Series

    20/40

    ERROR LISTING

    CXCM ControllerA-Post 2

    I/O Name / PinPriorit Indicator / A-P

    SPN Description Detected Faults Out / Diagnosticy Troubleshoot

    Function

    Menu

    0054Header Lower

    SolenoidLow

    FMI 11 - High Side Smart

    Driver Error

    HSD_6 /

    CN1-A12 /

    S

    Header /

    Header

    0055Right Group

    Lights 1Low

    FMI 11 - High Side Smart

    Driver Error

    HSD_7 /

    CN1-A6 /

    S

    Combine /

    Lighting

    0056

    Left

    Group

    Lights 1

    Low

    FMI 11

    - High

    Side

    Smart

    Driver

    Error

    HSD_8 /

    CN1-A13 /

    S

    Combine /

    Lighting

    0057Reel Down

    SolenoidLow

    FMI 11 - High Side Smart

    Driver Error

    HSD_9 /

    CN1-A7 /

    S

    Header /

    Reel

    0058Reel Fore

    SolenoidLow

    FMI 11 - High Side Smart

    Driver Error

    HSD_10 /

    CN3-B13 /

    S

    Header /

    Reel

    0059Moistener

    Bypass RelayLow

    FMI 11 - High Side Smart

    Driver Error

    HSD_11 /

    CN3-B5 /If fault detected,

    57-20

  • 7/25/2019 Alarms and Error Codes 88 Series

    21/40

    ERROR LISTING

    CXCM Controller

    A-Post 2I/O Name / Pin

    Priorit Indicator / A-PSPN Description Detected Faults Out / Diagnostic

    y Troubleshoot Function

    Menu

    0060Header Tilt CW

    SolenoidLow

    FMI 11 - High Side Smart

    Driver Error

    HSD_12 /

    CN3-B14 /

    S

    Header /

    Tilt

    0061Header Tilt

    CCW SolenoidLow

    FMI 11 - High Side Smart

    Driver Error

    HSD_13 /

    CN3-B6 /

    S

    Header /

    Tilt

    0062Left Group

    Lights 2Low None

    HSD_14 /

    CN3-B15 /

    S

    Combine /

    Lighting

    0063

    Selector

    (Swap) Valve

    Solenoid

    LowFMI 11 - High Side Smart

    Driver Error

    HSD_15 /

    CN3-B7 /

    S

    Header /

    Header

    0064

    Unloader

    Auger

    Solenoid

    LowFMI 11 - High Side Smart

    Driver Error

    HSD_16 /

    CN3-B16 /

    S

    Combine /

    Sieve &

    Unloader

    0065Right Group

    Lights 2Low None

    HSD_17 /

    CN3-B8 /

    S

    Combine /

    Lighting

    0066Reel Aft

    SolenoidLow

    FMI 11 - High Side Smart

    Driver Error

    HSD_18 /

    CN3-B17 /

    S

    Header /

    Reel

    57-21

  • 7/25/2019 Alarms and Error Codes 88 Series

    22/40

    ERROR LISTING

    CXCM ControllerA-Post 2

    I/O Name / PinPriorit Indicator / A-P

    SPN Description Detected Faults Out / Diagnosticy Troubleshoot

    Function

    Menu

    0067Reel Up

    SolenoidLow

    FMI 11 - High Side Smart

    Driver Error

    HSD_19 /

    CN3-B9 /

    S

    Header /

    Reel

    0068Header Tilt

    Current SenseMedium

    FMI 5 - If Header CW or

    CCW is ON and actual

    current is less than of

    desired current.

    FMI 6 - If Header CW or

    CCW is ON and actual

    current is more than twicethe desired current, OR if

    CW and CCW are OFF and

    actual current is above 100

    mA.

    *Header Tilt current sense

    faults are detected only

    when control is in Manual

    Mode.

    CRSN_1 /CN2-A8 /

    mA

    Header /

    Tilt

    m

    0069 SpareCRSN_2 /

    CN2-A1

    0070

    Moisture

    Temperature

    Sensor

    LowFMI 1 - Input valid but below

    normal (< -100 degC)

    CRSN_3 /

    CN2-A2 /If fault detected,

    0071 Not AvailableCRSN_4 /

    CN2-A3 /

    57-22

  • 7/25/2019 Alarms and Error Codes 88 Series

    23/40

    ERROR LISTING

    CXCM Controller

    A-Post 2I/O Name / Pin

    Priorit Indicator / A-PSPN Description Detected Faults Out / Diagnostic

    y Troubleshoot Function

    Menu

    0072

    Left Group

    Lights 1

    Current Sense

    Low

    CRSN_5 /

    CN2-A4 /

    mA

    Combine /

    Lighting

    m

    0073

    Right Group

    Lights 1

    Current Sense

    Low

    FMI 5 - If ON, Current < 1A

    for ROW & ANZ,

    else < 2.75A.

    * Input Voltage is battery

    compensated to 12V supply

    FMI 6 - If OFF, Current >

    0.5A

    CRSN_6 /

    CN2-A5 /

    mA

    Combine /

    Lighting

    m

    0074 Not AvailableCRSN_7 /

    CN2-A6 /

    0075 Spare CRSN_8 /CN2-A7 /

    0076Header Height

    Current SenseMedium

    FMI 5 - If Header Raise or

    Lower is ON and actual

    current is less than of

    desired current.

    FMI 6 - If Header Raise or

    Lower is ON, and actual

    current is more than twice

    the desired current, OR if

    Header Raise and Lowerare OFF and actual current

    is above 100 mA.

    *Header Height current sense

    faults are detected only

    when control is in Manual

    CRSN_9 /

    CN2-A13 /

    mA

    Header /

    Header

    m

    57-23

  • 7/25/2019 Alarms and Error Codes 88 Series

    24/40

    ERROR LISTING

    CXCM ControllerA-Post 2

    I/O Name / PinPriorit Indicator / A-P

    SPN Description Detected Faults Out / Diagnosticy Troubleshoot

    Function

    MenuMode.

    0077 Not AvailableCRSN_10 /

    CN3-B1 /

    0078 SpareCRSN_11 /

    CN3-B2 /

    0079 SpareCRSN_12 /

    CN2-B18 /

    0080 SpareCRSN_13 /

    CN3-B10 /

    0081Reel Drive

    Current SenseLow

    FMI 5 - If Reel Drive is ONand actual current is less

    than of desired current.

    FMI 6 - If Reel Drive is ON

    and actual current is more

    than twice the desired

    current, OR if Reel Drive is

    OFF and actual current is

    above 100 mA.

    CRSN_14 /

    CN3-B3 /

    mA

    Header /

    Reel

    m

    0082Signal Valve

    Current SenseLow

    FMI 5 - If Signal Valve is ONand actual current is below

    680 mA.

    FMI 6 - If Signal Valve is ON

    and actual current is above

    2.72 A, OR if Signal Valve is

    CRSN_15 /

    CN3-B4 /

    mA

    Combine /

    Combine

    m

    57-24

  • 7/25/2019 Alarms and Error Codes 88 Series

    25/40

    ERROR LISTING

    CXCM Controller

    A-Post 2I/O Name / Pin

    Priorit Indicator / A-PSPN Description Detected Faults Out / Diagnostic

    y Troubleshoot Function

    MenuOFF and actual current is

    above 100 mA.

    * Input Voltage is battery

    compensated to 12V supply

    0083Sieve Open

    RelayLow

    LSD_4 / CN2-

    A19 /

    S

    Combine /

    Sieve &

    Unloader

    0084Sieve Close

    Relay

    Low

    FMI 3 - Shorted to High

    Source (detected with relay

    ON only)

    FMI 4 - Open or Shorted to

    Low Source (detected with

    relay OFF only)

    LSD_9 / CN3-

    B27 /

    S

    Combine /

    Sieve &

    Unloader

    0085

    A-Post 2

    Communicatio

    ns

    MediumFMI 12 A-Post 2 not

    detected on CAN bus.

    NA /

    NA /

    S

    Combine /

    Combine

    0086Multi-Function

    Handle Input 1High

    FMI 14 SW_18 input is

    shorted to ground or any of

    the Low Side Drivers

    MFHOUT8 (CN2-A26),

    MFHOUT9 (CN2-A25), or

    MFHOUT10 (CN2-A24) may

    be shorted to ground.

    SW_18 /

    CN3-A21 /

    Header /

    Not Applicable

    57-25

  • 7/25/2019 Alarms and Error Codes 88 Series

    26/40

    ERROR LISTING

    CXCM ControllerA-Post 2

    I/O Name / PinPriorit Indicator / A-P

    SPN Description Detected Faults Out / Diagnosticy Troubleshoot

    Function

    Menu

    0087Multi-Function

    Handle Input 2High

    FMI 14 SW_17 input is

    shorted to ground or any of

    the Low Side Drivers

    MFHOUT8 (CN2-A26),

    MFHOUT9 (CN2-A25), or

    MFHOUT10 (CN2-A24) may

    be shorted to ground.

    SW_17 /

    CN3-A20 /

    Header /

    Not Applicable

    0088Multi-Function

    Handle Input 3High

    FMI 14 SW_16 input is

    shorted to ground or any of

    the Low Side DriversMFHOUT8 (CN2-A26),

    MFHOUT9 (CN2-A25), or

    MFHOUT10 (CN2-A24) may

    be shorted to ground.

    SW_16 /

    CN3-A15 /

    Header /

    Not Applicable

    0089Multi-Function

    Handle Input 4High

    FMI 14 SW_15 input is

    shorted to ground or any of

    the Low Side Drivers

    MFHOUT8 (CN2-A26),

    MFHOUT9 (CN2-A25), or

    MFHOUT10 (CN2-A24) may

    be shorted to ground.

    SW_15 /

    CN3-A14 /

    Header /

    Not Applicable

    57-26

  • 7/25/2019 Alarms and Error Codes 88 Series

    27/40

    ERROR LISTING

    CXCM Controller

    A-Post 2I/O Name / Pin

    Priorit Indicator / A-PSPN Description Detected Faults Out / Diagnostic

    y Troubleshoot Function

    Menu

    0090Multi-Function

    Handle Input 5High

    FMI 14 SW_9 input is

    shorted to ground or any of

    the Low Side Drivers

    MFHOUT8 (CN2-A26),

    MFHOUT9 (CN2-A25), or

    MFHOUT10 (CN2-A24) may

    be shorted to ground.

    SW_9 /

    CN1-B27 /

    Header /

    Not Applicable

    0091Multi-Function

    Handle Input 6High

    FMI 14 SW_7 input is

    shorted to ground or any of

    the Low Side DriversMFHOUT8 (CN2-A26),

    MFHOUT9 (CN2-A25), or

    MFHOUT10 (CN2-A24) may

    be shorted to ground.

    SW_7 /

    CN1-B24 /

    Header /

    Not Applicable

    0092Multi-Function

    Handle Input 7High

    FMI 14 AN_15 input is

    shorted to ground or any of

    the Low Side Drivers

    MFHOUT8 (CN2-A26),

    MFHOUT9 (CN2-A25), or

    MFHOUT10 (CN2-A24) maybe shorted to ground.

    AN_15_SW /

    CN3-A18 /

    Header /

    Not Applicable

    0093

    Horizontal

    Reel Position

    Sensor (Auger

    and Draper

    LowFMI 3 Voltage > 4.8 volts

    FMI 4 Voltage < 0.2 volts

    AN31 /

    CN3-A16 /

    V

    Header / Reel

    57-27

  • 7/25/2019 Alarms and Error Codes 88 Series

    28/40

    ERROR LISTING

    CXCM ControllerA-Post 2

    I/O Name / PinPriorit Indicator / A-P

    SPN Description Detected Faults Out / Diagnosticy Troubleshoot

    Function

    MenuGrain Headers

    Only)

    57-28

  • 7/25/2019 Alarms and Error Codes 88 Series

    29/40

    ERROR LISTING

    ERROR CODE LISTING

    APOST ERROR LISTING

    A Post Error Listing

    SPN Description Priority Detected Faults

    I/O Name /

    Pin Out /

    Diagnostic

    Function

    A-Post 2

    Indicator /

    Troubleshoo

    t Menu

    A-Post

    0128

    Coolant

    Temperature

    Sensor (mechanical

    engine only)

    MediumNone: 0 to 5V input values

    are valid.

    Ain1 /

    J3-6 /

    T

    Engine /

    Engine

    0129 Fuel Level Sensor MediumFMI 3 - Voltage > 4.8 volts

    FMI 4 - Voltage < 0.2 volts

    Ain2 /

    J3-5 /V

    Engine /

    Engine

    0130 Spare Ain3 / J3-11

    0131 Spare Ain4 / J3-12

    0132Tailings Volume

    SensorLow

    FMI 3 - Voltage > 4.95 volts

    FMI 4 - Voltage < 0.05 volts

    Ain5 /

    J3-13 /

    V

    Combine /

    Combine

    0133Concave Position

    SensorLow

    FMI 3 - Voltage > 4.7 volts

    FMI 4 - Voltage < 0.3 volts

    Ain6 /

    J3-7 /

    V

    Combine /

    Combine

    0134Spreader Position

    SensorLow

    FMI 3 - Voltage > 3.0 volts

    FMI 4 - Voltage < 0.05 volts

    Ain7 /

    J3-17 /

    V

    Combine /

    Combine

    0135 Spare Ain8 / J3-18

    0136 Spare Ain9 / J3-19

    57-29

  • 7/25/2019 Alarms and Error Codes 88 Series

    30/40

    ERROR LISTING

    A Post Error ListingI/O Name / A-Post 2

    Pin Out / Indicator / A-PostSPN Description Priority Detected Faults

    Diagnostic Troubleshoo

    Function t Menu0137 Spare Ain10 / J3-26

    0138 Spare Ain11 / J3-25

    0139 Spare Ain12 / J3-24

    0140 Not Available Ain13 / J3-20

    0141 Not Available Ain14 / J3-21

    0142 Not Available Ain15 / J3-22

    0143 Not Available Ain16 / J3-23

    0144 Alternator Medium None

    ALT /

    J2-1 /

    V

    Combine /

    Voltage

    12

    0145 Ignition High

    FMI 3 - Voltage > 15 Volts

    FMI 4:

    Voltage < 11.5V, engine on

    Voltage < 10V, engine off

    Keyed_B+ /

    J2-2 /

    V

    Combine /

    Voltage

    12

    0146 +5V Sensor Out MediumFMI 3 - Voltage > 5.5 volts

    FMI 4 - Voltage < 4.5 volts

    +5V

    SENSOR /

    J2-10

    V

    Combine /

    Voltage

    5 v

    0147Display

    TemperatureLow

    FMI 3 - Voltage > 2.0 volts

    (150 Deg C)

    FMI 4 - Voltage < 0.03 volts

    (-47 Deg C)

    TEMP_SENSE /

    J4-10 /

    T

    Combine /

    CombineA

    57-30

  • 7/25/2019 Alarms and Error Codes 88 Series

    31/40

    ERROR LISTING

    A Post Error Listing

    I/O Name / A-Post 2

    Pin Out / Indicator / A-PostSPN Description Priority Detected Faults

    Diagnostic Troubleshoo

    Function t Menu

    0148 +12V Sensor Out MediumFMI 4 (Voltage + 3V)