AIRWAY MANAGEMENT INCRITICAL CARE MEDICINE

Rüdiger NOPPENS, MD, PhDAssociate Professor

Tim PIEPHO, MD, PhDAssociate Professor

Department of AnesthesiologyMedical Center of theJohannes Gutenberg

University, Mainz, Germany

®

Page 4: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine4

Illustration:Yvan Freund, 67000 Straßburg, Francewww.yvanfreund.com

Airway Management in Critical Care MedicineRüdiger Noppens, MD, PhD, Associate Professor Tim Piepho, MD, PhD, Associate ProfessorDepartment of AnesthesiologyMedical Center of the Johannes Gutenberg University,Mainz, Germany

Correspondence address of the author: Rüdiger Noppens, MD, PhD, Associate Professor Tim Piepho, MD, PhD, Associate ProfessorDepartment of AnesthesiologyMedical Center of the Johannes Gutenberg University,Mainz, GermanyLangenbeckstr. 1, 55131 Mainz, GermanyE-mail: [email protected] [email protected]

All rights reserved.1st edition 2013© 2015 ® GmbHP.O. Box, 78503 Tuttlingen, GermanyPhone: +49 (0) 74 61/1 45 90Fax: +49 (0) 74 61/708-529E-mail: [email protected]

No part of this publication may be translated, reprinted or reproduced, transmitted in any form or by any means, electronic or mechanical, now known or hereafter invent-ed, including photocopying and recording, or utilized in any information storage or retrieval system without the prior written permission of the copyright holder.

Editions in languages other than English and German are in preparation. For up-to-date information, please contact

® GmbH at the address shown above.

Design and Composing:® GmbH, Germany

Printing and Binding:Straub Druck + Medien AGMax-Planck-Straße 17, 78713 Schramberg, Germany

07.15-0.5

ISBN 978-3-89756-769-6

Important notes:

Medical knowledge is ever changing. As new research and clinical experience broaden our knowledge, changes in treat ment and therapymay be required. The authors and editors of the material herein have consulted sources believed to be reliable in their efforts to provide information that is complete and in accord with the standards accept ed at the time of publication. However, in view of the possibili ty of human error by the authors, editors, or publisher, or changes in medical knowledge, neither the authors, editors, publisher, nor any other party who has been involved in the preparation of this booklet, warrants that the information contained herein is in every respect accurate or complete, and they are not responsible for any errors or omissions or for the results obtained from use of such information. The information contained within this booklet is intended for use by doctors and other health care professionals. This material is not intended for use as a basis for treatment decisions, and is not a substitute for professional consultation and/or use of peer-reviewed medical literature.

Some of the product names, patents, and re gistered designs referred to in this booklet are in fact registered trademarks or proprietary names even though specifi c reference to this fact is not always made in the text. Therefore, the appearance of a name without designation as proprietary is not to be construed as a representation by the publisher that it is in the public domain.

The use of this booklet as well as any implementation of the information contained within explicitly takes place at the reader’s own risk. No liability shall be accepted and no guarantee is given for the work neither from the publisher or the editor nor from the author or any other party who has been involved in the preparation of this work. This particularly applies to the content, the timeliness, the correctness, the completeness as well as to the quality. Printing errors and omissions cannot be completely excluded. The publisher as well as the author or other copyright holders of this work disclaim any liability, particularly for any damages arising out of or associated with the use of the medical procedures mentioned within this booklet.

Any legal claims or claims for damages are excluded.

In case any references are made in this booklet to any 3rd party publication(s) or links to any 3rd party websites are mentioned, it is made clear that neither the publisher nor the author or other copyright holders of this booklet endorse in any way the content of said publication(s) and/or web sites referred to or linked from this booklet and do not assume any form of liability for any factual inaccuracies or breaches of law which may occur therein. Thus, no liability shall be accepted for content within the 3rd party publication(s) or 3rd party websites and no guarantee is given for any other work or any other websites at all.

Page 5: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 5

Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Special Issues in Critical Care Medicine . . . . . . . . . . . 9The Critically Ill Patient . . . . . . . . . . . . . . . . . . . . . . . 9Incidence of Diffi cult Airways in Critical Care Medicine . . . . . . . . . . . . . . . . . . . . . . 9

Defi nition of the Diffi cult Airway . . . . . . . . . . . . . . . . . . 10Complications of Endotracheal Intubation in Critical Care Medicine . . . . . . . . . . . . . . . . . . . . . . 11Special Problems in the Intensive Care Unit . . . . . 11Training of ICU Physicians in Airway Management . . . . . . . . . . . . . . . . . . . . . . . 11

Equipment for Airway Management . . . . . . . . . . . . . . . 12

Predictors of a Diffi cult Airway . . . . . . . . . . . . . . . . . . . 14

Securing the Airway . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Preoxygenation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Endotracheal Intubation . . . . . . . . . . . . . . . . . . . . . . 16

Induction Agents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Hypnotics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Neuromuscular Blockade . . . . . . . . . . . . . . . . . . . . . 16Opioids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Positioning the Head. . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Orotracheal Intubation . . . . . . . . . . . . . . . . . . . . . . . . . . 18Direct Laryngoscopy . . . . . . . . . . . . . . . . . . . . . . . . . 18Verifi cation of Tube Placement . . . . . . . . . . . . . . . . 20Management of Diffi cult Direct Laryngoscopy . . . 21

The C-MAC® Video Laryngoscope . . . . . . . . . . . . . . . . 22Technique of Video Laryngoscopy . . . . . . . . . . . . . 23Glottic Visualization and Intubation Success with the Video Laryngoscope . . . . . . . . . . . . . . . . . . 25Video Laryngoscopy in Critical Care Medicine . . . 26

Supraglottic Airway Devices . . . . . . . . . . . . . . . . . . . . . 26

Laryngeal Masks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Classic Laryngeal Mask . . . . . . . . . . . . . . . . . . . . . . 28Laryngeal Masks with an Esophageal Lumen . . . 29Laryngeal Masks for Endotracheal Intubation . . . 30

Devices with an Esophagealand Oropharyngeal Cuff . . . . . . . . . . . . . . . . . . . . . . . . . 31

Combitube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31EasyTube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Laryngeal Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Laryngeal Tube Suction (LTS) . . . . . . . . . . . . . . . . . . 34

Flexible Endoscopic Intubation . . . . . . . . . . . . . . . . . . . 34Flexible Endoscopic Intubation in the Awake Patient . . . . . . . . . . . . . . . . . . . . . . . . . 35Oxygenation during Flexible Endoscopic Intubation . . . . . . . . . . . . . . . . . . . . . . . 35Patient Sedation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Flexible Nasotracheal Endoscopic Intubation . . . 37Flexible Orotracheal Endoscopic Intubation . . . . . 39Flexible Endoscopic Intubation in the Anesthetized Patient . . . . . . . . . . . . . . . . . . . . 40Flexible Endoscopic Intubation of an Unanticipated Diffi cult Airway . . . . . . . . . . . . 40Flexible Endoscopic Intubation Through the Laryngeal Mask . . . . . . . . . . . . . . . . . . 41Flexible Endoscopically Assisted Percutaneous Dilatational Tracheotomy . . . . . . . . . . . . . . . . . . . . . 42

Invasive Airway Access in Patientswith Failed Oxygenation or Patientswith Failed Oxygenation and Ventilation . . . . . . . . . . . 44

Surgical Airway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Needle Cricothyrotomy . . . . . . . . . . . . . . . . . . . . . . . 46Transtracheal Jet Ventilation (TJV) . . . . . . . . . . . . . 47Evaluation of Various InvasiveAirway Techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Emergency Algorithm for Airway Managementin the ICU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Mainz Emergency Algorithm for an Unanticipated Diffi cult Airway . . . . . . . . . . . . . . . . . 50

References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Page 6: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine6

Introduction

The principal reason for admitting a critically ill patient to an intensive care unit (ICU) is respiratory failure1. A vast array of techniques and equipment are available in modern critical care medicine for the management of respiratory dysfunction. In recent years, noninvasive ventilation with a face mask or helmet has become an increasingly important ventilatory modality in critical care settings2 (Fig. 1). Nevertheless, some patients with conditions such as acute lung failure (ARDS) will continue to require urgent endotracheal intubation, and a variety of strategies must be available for providing invasive ventilation3. Besides ventilation with a face mask or classic endotracheal tube, supraglottic airway devices are also available. These devices are useful for providing short-term ventilation and oxygenation, especially in emergency situations. Examples are the laryngeal mask and laryngeal tube. These devices cannot replace the endotracheal tube in everyday clinical care, however, and serve only as adjuncts until a defi nitive airway can be established by endotracheal intubation or tracheotomy. The advantages of securing the airway with a cuffed tube include:

� the prevention of gastric insuffl ation � relative protection from tracheal aspiration of fl uids and solid foreign bodies

� allows for special ventilatory techniques such as high-frequency oscillatory ventilation (HFOV)

� allows for controlled ventilation at high positive pressures (e.g., PEEP)

� allows for selective tracheal or bronchial administration of pharmacologic agents through the indwelling tube

� provides access for bronchoscopy and bronchial lavage � permits the selective sampling of tracheal secretions for microbiological testing

Endotracheal intubation is usually performed with a laryngo-scope and Macintosh blade4 (Fig. 2). This technique is also called direct laryngoscopy because it affords a direct view of the laryngeal inlet (Fig. 3). But as several authors have pointed out, securing the airway in an ICU is associated with more complications and a higher rate of diffi cult intubations than in anesthesiology5, 6. As a result, there have been increasing efforts in recent years to develop devices that can improve visualization of the glottic plane even in patients with a diffi cult airway7. Most of these innovative devices do not require a direct line of sight to visualize the vocal cords, relying instead upon a camera or optical system that displays an eyepiece or monitor image of the laryngeal inlet

Noninvasive ventilation with a CPAP helmet.

1

Laryngoscope with a Macintosh blade.2

Visualization of the glottis by direct laryngoscopy.3

Page 7: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 7

Video-assisted intubation with the C-MAC® video laryngoscope.4

Video-assisted fi beroptic intubation in the awake patient. 5

Portable airway cart for in-hospital use.6

(Figs. 4, 5). This technique is often called indirect laryngo-scopy, therefore. Available data suggest that indirect laryngoscopy will fi nd growing applications in the everyday practice of critical care. Because complications are especially likely to arise during the airway management of critically ill patients with decreased physiologic reserves, every ICU should stock a number of alternative devices for establishing a secure airway. The specifi c assortment of devices will de-pend on local circumstances. No single conventional device is suitable for every conceivable situation that may occur during airway management. Multiple techniques and devices should be on hand for managing any complication that may arise during endotracheal intubation. Experience has shown that it is best to stock devices that can be used for routine

applications such as elective general anesthesia. When these devices are used routinely, the practitioners will already have a high degree of expertise when confronted with an emer-gency situation, since every instrument and device will have its own learning curve. Consequently, intensivists familiar with airway management should be trained in the use of these devices.

It is not practical to stock a variety of airway adjuncts at every patient bed in the ICU. A better solution is to employ rugged airway carts that can be individually outfi tted and wheeled quickly to the bedside, delivering all materials and equipment necessary for elective or emergency airway management (Fig. 6).

Page 8: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine8

Flexible intubation fi berscope, kept in a special “quiver” on the airway cart.

7 Flexible intubation fi berscope with attached battery light source.8

Percutaneous dilatational tracheotomy guided by video endoscopy.9

A common procedure in critical care medicine is bronchos-copy for the diagnosis and treatment of conditions such as atelectasis due to retained secretions8. Percutaneous dilatational tracheotomy under endoscopic guidance has also become a fairly standard procedure in critical care settings9, 10.Thus, a bronchoscope or at least a large-bore intubation endoscope should be available in every ICU where patients

are being ventilated. Ideally, this instrument should be kept on the airway cart so that it will be quickly available when needed (Fig. 7). The use of a battery unit and portable light source has proven helpful (Fig. 8). Immediate accessibility is crucial in the management of an unanticipated diffi cult airway. The optional use of a monitor system is particularly useful in performing a percutaneous dilatational tracheotomy (Fig. 9).

Page 9: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 9

The Cormack-Lehane classifi cation of laryngoscopic airway views.(Cormack RS, Lehane J: Diffi cult tracheal intubation in obstetrics. Anaesthesia. 1984;39:1105-11.)

10

� �

� �

Special Issues in Critical Care Medicine

The Critically Ill Patient ICU patients are generally very sick and have greatly diminished physiologic reserves. Many of them will require circulatory and respiratory support. Patients in respiratory failure are frequently admitted to the ICU. Once improved past the critical stage, patients are weaned from the ventilator and fi nally extubated. Some of these patients will have to be reintubated because their general health status does not allow for adequate spontaneous breathing. Intensivists, then, must have a broad knowledge of circulatory and respiratory therapies. Clinical experience and detailed background knowledge are essential to ensure that anesthesia induction and airway management by endotracheal intubation can be successfully accomplished in this complex subset of patients.

The problems of scant respiratory and cardiovascular reserves are often compounded by an associated impairment of consciousness. Since many of these patients are not fasted, they are also susceptible to the aspiration of gastric contents. Due to their critical health status, therapeutic decisions must be made quickly and purposefully to ensure the provision of appropriate care.

This is in contrast to the majority of patients who are treated electively in an operating room setting. These patients are usually well prepared, fasted, and rarely have a life-threatening illness. Anesthesia induction is not urgent in most cases and – unlike the conditions in an ICU – can be performed with optimum staffi ng, equipment, and working space.

Incidence of Diffi cult Airways in Critical Care Medicine In our own study of 140 endotracheal intubations in an anesthesia-led ICU, we documented a 21% incidence of diffi cult intubation, defi ned as a Cormack-Lehane grade of III or IV11 (Fig. 10). In 7% of the patients, more than two intubation attempts were necessary to secure the airway. A group of French authors reported a 12% incidence of diffi cult intubation in ICU patients6. One study in over 3400 patients found a 10.3% incidence of diffi cult endotracheal intubation in all nonoperating-room intubations, with 3% of patients requiring three or more attempts12. Another study in more than 1000 patients found that more than two intubation attempts were needed13. By contrast, the incidence of diffi cult intubation in the operating room is only about 5%14. The incidence of diffi cult airways in prehospital emergency settings is comparable to that in the ICU: 15–19% with a Cormack-Lehane grade of III or IV15, 16. These fi gures clearly demonstrate that airway management in the ICU is a very demanding task with a high complication rate. For these reasons, intensivists must have comprehensive training and experience that will enable them to manage critically ill patients safely and effectively.

Grade I � The vocal cords are fully visible. Grade II � Only the arytenoid area and posterior part of the

glottic opening are visible.

Grade III � Only the epiglottis is visible.Grade IV � View is limited to the soft palate (pharyngeal structures

cannot be seen).

Grade I

Grade III

Grade II

Grade IV

Page 10: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine10

Defi nition of the Diffi cult AirwayVarious defi nitions of a diffi cult airway have been presented in the literature. According to the guidelines of the German Society of Anesthesiology and Intensive Care Medicine (DGAI), a diffi cult airway is present when an anesthesiologist of average training experiences diffi culty with mask ventilation or tracheal intubation4.

Intubation is classifi ed as diffi cult if successful endotracheal tube placement by conventional laryngoscopy requires more than three attempts or takes longer than 10 minutes.

Inability to intubate often presents as a diffi cult direct laryn-goscopy in which the glottic plane cannot be visualized well enough to allow safe placement of the endotracheal tube.

If failed intubation is accompanied by failure of bag-and-mask ventilation, a “cannot ventilate – cannot intubate” situation exists that is acutely life-threatening to the patient. Instead of wasting time with more failed intubation attempts, the intensivist should change to an alternative technique as shown in the Noppens-Piepho Algorithm for Emergency Air-way Management (see diagram).

In-hospital algorithm for the management of an unanticipated diffi cult airway. Mask ventilation is the starting point because it generally represents the fi rst backup option. The selection of a particular device is based on availability and experience. SP = specialist.

Noppens-Piepho Algorithm for Emergency Airway Management

YES

YES

YES

NO

NO

NO

NO

NO NO

NO

NO

NO NO

EMERGENCY: Call for help.Consider neuromuscular blockade;

SP: one intubation attempt(video laryngoscope)

Adequate mask ventilationpossible?

Maximum of 3 intubation attempts (by SP); if possible:

video laryngoscope; call for help

Successful?Successful?

Successful?

Successful? Successful?

Successful?

Adequate mask ventilationpossible?

Return to spontaneous breathingis possible – wake the patient?

Consider antagonists(e.g., sugammadex, naloxone)

Video laryngoscope /alternative blades Supraglottic airway device Flexible or rigid

intubation endoscope

ONE alternative

Videolaryngoscope /

alternative bladesFlexible or

rigid endoscopeSupraglottic

device

Return to spontaneous breathingis possible – wake the patient?

Consider antagonists(e.g., sugammadex, naloxone)

Adequate mask ventilationpossible?

Surgical or percutaneous cricothyrotomy

Page 11: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 11

Complications of Endotracheal Intubation in Critical Care Medicine Various life-threatening complications may arise during endotracheal intubation (see Table 1). in a multicenter study of 250 ICU patients, at least one life-threatening complication was documented in 28% of endotracheal intubations. Severe hypoxia occurred in 26% of these patients, severe hypotension in 25%, and cardiac arrest in 2%. Other complications were cardiac arrhythmias (10%), esophageal intubation (5%), and aspiration (2%)6. Another study alsofound a high incidence of potentially life-threatening complications, with severe hypoxia occurring in 19% of the patients, severe hypotension in 10%, esophageal intubation in 7%, and aspiration in 6%5. The incidence of cardiac arrest during airway management is signifi cantly higher outside the operating room: 17.2% of the patients in the study suffered cardiac arrest, and severe hypoxia (SaO2 < 70%) was identifi ed as the cause in most cases. The risk of cardiac arrest was increased in cases where regurgitation, aspiration, esophageal intubation, or bradycardia occurred during intubation.

Table 1 Frequent complications of intubation in the ICU.

Special Problems in the Intensive Care Unit Because of space limitations, it is more diffi cult to establish an airway in the ICU than in the operating room. The patient is surrounded by myriad devices such as the ventilator, monitors, hemofi ltration devices, and infusion pumps. Infu-sion lines and cables may hamper direct access to the head of the ICU bed (Fig. 11). Moreover, special beds (e.g., ICU beds with an integrated air mattress) and devices immobiliz-ing the cervical spine can hamper access to the patient’s head and make it diffi cult to position the head for intubation. Space constraints may hinder assisting personnel in provid-ing patient care. Often the available space is already occupied by ICU devices, making it a challenge to get the airway cart close to the patient.

� Severe hypoxia (SpO2 < 80%) � Severe hypotension � Cardiac arrest � Cardiac arrhythmia � Esophageal intubation � Aspiration

Training of ICU Physicians in Airway Management The physician staffi ng of ICUs varies widely at different institutions18. In Germany, it has been found that staffi ng ICUs with physicians trained in critical care is associated with signifi cantly better patient outcomes. Based on available data on airway management complications in critical care medicine, physicians who work in a critical care setting should receive competent training in airway management19. To date, however, this requirement has not been implemented on a broad scale and many doctors who work in ICUs are not adequately trained in airway management. One reason for this may lie in different specialty backgrounds: In Germany, various specialties such as internal medicine, surgery, pediatrics, and anesthesiology are concerned chiefl y with the provision of intensive care. Few of these specialties devote much attention to the practice of airway management. This led some authors to conclude that critical airway situations should be handled only by an anesthesiologist, who is an “airway specialist”20. Currently, however, there is no scientifi c evidence to support this requirement. In principle, specialty training in critical care medicine does not ensure profi ciency in successful endotracheal intubation. The ability to secure an airway is gained chiefl y through clinical experience. Expertise in airway management is based on comprehensive medical and pharmacologic knowledge and on clinical experience with the various methods of establishing an airway. Studies indicate that 50 to 100 endotracheal intubations performed under supervision with a laryngoscope and Macintosh blade are necessary to become fully profi cient in this technique21, 22.

The practical implementation of an airway management algorithm, a standard protocol for anesthesia induction, and easy access to airway devices and alternatives have proven helpful in reducing serious complications of airway management 23, 24.

Typical ICU equipment layout, with limited patient access.11

Page 12: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine12

In dealing with each of the available devices and adjuncts, the operator must gain enough practice to be able to use the devices immediately, successfully, and safely even in emergency settings.

The airway management guideline of the DGAI describes a four-step process for learning the principles of airway management4. These principles are applicable to all techniques and procedures for airway management in critical care medicine (Table 2).

Infi nity Delta XL patient monitor (Dräger Medical GmbH, Lübeck, Germany) with capnographic display.

12

Table 2 Sequence of steps in learning the principles of airwaymanagement.

� Learn basic theory. � Practice basic principles on an airway trainer. � Perform the technique or procedure in a patient under supervision.

� Perfect the acquired skills. Place an airway in patients with an anticipated diffi cult airway. Participate in continuing education and training.

Equipment for Airway Management

Every ICU should be equipped with a standard airway cart to ensure the rapid availability of necessary airway devices and adjuncts. One survey conducted in the U.S. found that only 75% of the ICUs polled had equipment for endotracheal intubation available in the ICU as a set25. Fifty percent of the ICUs reported having a diffi cult-airway cart or tote bag available within the unit. A survey conducted in Great Britain found that basic equipment for endotracheal intubation (ventilation bag, laryngoscope, laryngeal mask) was available in all of the ICUs26. Surprisingly, however, only 32% of the units routinely used capnography for the verifi cation of tube placement after endotracheal intubation. This is unusual when we consider that since 1991, the American Society of Anes-thesiologists (ASA) has recommended the measurement of end-tidal CO2 level as a basic monitoring test after anesthesia induction (Fig. 12).

Page 13: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 13

The end-tidal CO2 level measured for 60 seconds is a reliable indicator of successful ventilation and thus provides an indirect sign of successful intubation. For years, therefore, capnography has been a recognized standard in anesthesiology, and a capnometer should be available in all settings where patients are intubated. It is noteworthy that current German standards stipulate that rescue vehicles with a physician on board must be equipped with a capnometer for monitoring intubations in prehospital emergency settings.

Endotracheal intubation is the gold standard in critical care medicine for treating an oxygenation defi cit that cannot be managed by noninvasive ventilation. The ICU should be equipped with suitable instruments for anesthesia induction, therefore (Fig. 13).

Instrument set for anesthesia induction.13

Device CommentsVentilation mask Various sizes should be available

(e.g., mask sizes 3, 4, and 5)Ventilation bag Should be available at every patient

bed. FiO2 capacity should be > 0.9 (e.g., oxygen reservoir, demand valve)

Devices for maintaining a patent airway: Guedel tubes, Wendl tubes

Various sizes should be available (e.g., Guedel tube sizes 3, 4, and 5)

Laryngoscope handle Regularly check the battery charge Laryngoscope blade Macintosh blades in at least two

sizes: No. 3 and No. 4. Straight Miller blades may also be used, depending on in-house protocols

Suction device Check for function before every endotracheal intubation

Suction catheter Various sizesStylet Various sizes. Choose the stylet

that fi ts the inner diameter of the endotracheal tube. Gum elastic bougies may also be used

Capnometer E.g., a portable capnometer or one integrated into the monitoring system

Endotracheal tubes Various sizes (e.g., ID 6.5–9.0 mm) plus a 10-mL infl ation syringe

Pulse oximeter For monitoring oxygenation during airway management. Due to the delayed fall in oxygen saturation, especially after good preoxygenation, pulse oximetry is not useful for verifying correct endotracheal tube placement

Table 3 Essential devices for airway management in the ICU.

Device CommentsSupraglottic devices: such as the laryngeal mask, intubatinglaryngeal mask, laryngeal tube,and Combitube

The unit should be equipped with the supraglottic device that is most familiar through clinical use

Alternative laryngoscopesMcCoy blade,video laryngoscope

The use of video laryngoscopy as a standard procedure offers many advantages over conventional direct laryngoscopy (see Video Laryngoscopy in Critical Care Medicine, p. 26)

Flexible intubation endoscope

Intubation endoscope with a light source (e.g., a battery-powered LED light source)

Cricothyrotomy set An instrument set for surgical cricothyrotomy should always be available in addition to a needle cricothyrotomy kit

Table 4 Adjunctive devices for managing a diffi cult airway.

Page 14: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine14

Predictors of a Diffi cult Airway

If time allows, every endotracheal intubation should bepreceded by a review of the patient’s records and a comprehensive airway examination4. Airway assessment should also precede “urgent intubations” (for respiratory failure that worsens over a period of hours). Generally there is no time available for airway assessment in emergency intubations (for sudden respiratory arrest).

The anesthesia protocol may provide an important clue to an anticipated diffi cult airway. Especially in surgical patients, the anesthesia protocol will generally yield important information on the airway history. It may document possible complications during airway management such as diffi cult mask ventilation, diffi cult intubation, or the use of alternative airway devices.

Airway assessment should always include an evaluation of the mouth, face, teeth, jaw, tongue, neck, and cervical spine (Table 5). This process takes very little time (about 15 seconds) and can prevent potentially serious complications.

Macroglossia in a patient with Lenz-Majewski syndrome.14

Mallampati class IV: With the patient sitting and the tongue protruded, the uvula is not visible. Only the hard palate can be seen.

15 Morbidly obese patient with a short, thick neck.16

Predictors of a diffi cult airway

Mouth and pharynx

� Limited mouth opening (< 3 cm) � Limited range of TMJ motion(lower incisors cannot be moved anterior to the upper incisors)

� Dental status: long upper incisors (“buck teeth”)

� High, narrow palate(“gothic-arch” palate)

� Macroglossia (Fig. 14) � Uvula not visible with the patient sitting and the tongue protruded (Fig. 15)

� Jaw proportions � Retrognathia � Prognathia

� Upper airway tumorsFace � Congenital anomalies (e.g., trisomy 21,

Lenz-Majewski syndrome) � Scars � Trauma (e.g., midfacial fracture) � Edema

Neck � Limited cervical spine motion � Pronounced ankylosing spondylitis � Large tumors displacing the trachea � Prior surgery, scarring (e.g., neck dissection)

� Obesity with a short neck (Fig. 16)Table 5 Predictors of a diffi cult airway.

If one or more predictors of diffi cult intubation is found, the intubation should always be performed by a physician experienced in endotracheal intubation. The procedure of fi rst choice for anticipated diffi cult intubation is awake fl exible fi beroptic intubation (see Flexible Endoscopic Intubation, p. 35). Spontaneous respiration should be maintained in these patients until the endotracheal tube has been placed in the trachea4. This procedure, done under topical anesthesia, is successful in a high percentage of cases and can be performed at low risk27. Uncooperative patients may be carefully sedated (e.g., with opioids) to facilitate the procedure. The sedative dosage should be low enough to preserve spontaneous breathing.

Page 15: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 15

Preoxygenation by bag-and-mask ventilation with an attached reservoir bag.

17

Ventilation bag connected to a demand system.18 Preoxygenation by noninvasive CPAP ventilation with a mask.19

Securing the Airway

Preoxygenation Every critically ill patient in the ICU should be adequately preoxygenated before anesthesia induction. Preoxygenation washes nitrogen (approximately 78% content in ambient air) from the lungs and maximizes the functional residual capacity while producing maximum oxygen saturation in the blood.

The patient is preoxygenated by administering 100% oxygen through a ventilation mask placed fi rmly over the face. When a ventilation bag is used, the oxygen fl ow should be at least 15 L/min and a reservoir bag should be attached to the circuit to achieve the highest possible oxygen concentration (> 90%) (Fig. 17). The reservoir provides for oxygen enrichment in the ventilation bag. After each ventilation the attached reservoir refi lls the ventilation bag with 100% oxygen.

Another option is ventilation bags that can be connected to a demand system (Fig. 18). This arrangement can deliver a high FiO2 concentration within a short time.

The use of a nasal cannula or oxygen reservoir mask is inadequate for preoxygenation. These systems can provide only oxygen enrichment, so even with high oxygen fl ow they are very limited in the maximum inspiratory oxygen content that can be achieved (FiO2 = 30–75%, depending on the system used).

The use of a ventilation bag with oxygen delivery (reservoir bag or demand system) is a simple and effective preoxygenation method that can reduce the risk of severe hypoxia during airway placement. Preoxygenation before anesthesia induction should be continued for 3–4 minutes28. There appears to be no benefi t to extending the preoxy-genation period to more than 4 minutes29.

Especially in obese patients with an anticipated rapid fall in oxygen saturation, noninvasive ventilation (pressure support: 6 cm H2O, PEEP: 4 cm H2O) during preoxygenation was found to produce a markedly improved oxygen content in the arterial blood30. In another study of hypoxemic patients requiring intubation, it was found that preoxygenation by noninvasive ventilation led to signifi cantly fewer hypoxic events during intubation compared with conventional preoxygenation31. Preoxygenation was performed for 3 minutes using 100% oxygen, pressure support ventilation with a tidal volume of 7–10 mL/kg body weight, and a PEEP of 5 cm H2O. This study also demonstrated a positive effect on oxygenation for up to 5 minutes after endotracheal intubation.

Thus, the recommended preoxygenation method for critically ill patients in respiratory failure is noninvasive ventilation on 100% oxygen, pressure support of at least 6 cm H2O (target = 7–10 mL/kg b.w.), and a PEEP of at least 4 cm H2O for a period of 4 minutes (Fig. 19).

Page 16: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine16

Endotracheal Intubation The principal indications for endotracheal intubation in critical care medicine include the following:

As a general rule, critically ill patients are assumed to have a full stomach. Hence, there is always a risk of regurgitation and aspiration during airway management.

To reduce the likelihood of aspiration, rapid sequence induc-tion (RSI*) should always be performed during endotracheal intubation.

* So named because the normal sequence of intubation is shortened and some steps are omitted.

� Maintaining a patent airway � Oxygenation � Controlled ventilation � Protection from aspiration � Access for bronchial lavage

Hypnotic agents for anesthesia induction (etomidate and ketanest).

20

Muscle relaxants for rapid sequence induction (succinylcholine and rocuronium).

21

Induction Agents

Hypnotics The need for hypnotics during anesthesia induction is markedly decreased in critically ill patients who are hemodynamically unstable. Also, it is advisable to use drugs that cause as little cardiovascular suppression as possible (Fig. 20). The use of propofol for emergency intubation is associated with a higher risk of hypotension than etomidate32. On the other hand, induction with etomidate causes adrenocortical suppression and may be harmful for patients in septic shock33, 34. For these reasons, ketanest (0.5–1 mg/kg) is being used increasingly as a hypnotic agent for anesthesia induction in hemodynamically unstable patients24. Propofol is excellent for anesthesia induction in hemodynamically stable patients.

Neuromuscular Blockade Neuromuscular blockade is induced with muscle relaxants to improve the intubation conditions and obtain better visualization of the glottic plane. Currently two drugs are available for rapid sequence induction: succinylcholine and rocuronium (Fig. 21). Both agents have a rapid onset at the proper dosage and provide good intubation conditions. Succinylcholine (1–1.5 mg/kg) is a short-acting depolarizing muscle relaxant (approximately 7 minutes) with a rapid onset of action (30–60 seconds). A number of side effects and contraindications have been reported (Table 6). Many of the contraindications relate to critically ill patients in intensive care.

Table 6 Important contraindications to the use of succinylcholine.

Rocuronium is a non-depolarizing muscle relaxant. This drug has a rapid onset of action (60–90 seconds) when administered at high dosage (0.9–1.2 mg/kg), although this will also prolong the duration of the neuromuscular blockade (approximately 120 minutes). Sugammadex (16 mg/kg) can completely reverse the effect of rocuronium within 3 minutes (Fig. 22)35. The effects of succinylcholine and rocuronium were compared in a Cochrane meta-analysis36. Both drugs were found to produce equivalent intubation conditions, but succinylcholine was deemed superior based on its short duration of action.

� Hyperkalemia (> 5 mmol/l) � Burns � Stroke � Spinal injuries � Multiple sclerosis � Guillain-Barré syndrome � Degenerative or dystrophic muscle diseases � Immobilized patient (bed-confi ned for >3 days)

Page 17: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 17

Sugammadex can be administered for the prompt reversal of neuromuscular blockade by rocuronium.

22

Sufentanil can be used for anesthesia induction and themaintenance of sedation.

23

The head has been placed in the “sniffi ng position.”24

Neuromuscular blockade should be induced for every intubation in ICU because it signifi cantly improves the intubating conditions.

The use of succinylcholine is limited to selected cases due to its many possible side effects. When sugammadex is available, rocuronium (0.9–1.2 mg/kg) should be used routinely for neuromuscular blockade during endotracheal intubation in critical care medicine.

Opioids Opioids are traditionally used for anesthesia induction and the maintenance of sedation. Because tracheal intubation is a very potent stimulus, opioids (e.g., sufentanil at 0.2–0.4 μg/kg) are often administered as adjuncts to anesthesia induction (Fig. 23).

It should always be noted, however, that all drugs (opioids, hypnotics) administered in a suffi ciently high dose may cause hemodynamic instability in critically ill patients with a coexisting intravascular volume defi cit.

Positioning the Head

Before endotracheal intubation, the patient’s head should be placed in the “sniffi ng position” or modifi ed Jackson position. This is done by placing the head on an approximately 10-cm-high cushion or pillow and hyperextending the neck (Fig. 24). When the head is correctly positioned, direct laryngoscopy can provide the intubator with a straight line of sight past the upper incisors and through the oral cavity to the larynx(Fig. 25).

Creating a direct line of sight to the glottis.25

Page 18: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine18

Orotracheal Intubation

Direct Laryngoscopy Orotracheal intubation under direct vision is the standard procedure used for most patients. The Macintosh blade is most commonly used (Fig. 26). Use of the straight Miller blade (Fig. 27) differs in some respects from the technique with the Macintosh blade.

After positioning, preoxygenation, and pharmacologic anesthesia induction, the next step is to open the mouth with

Macintosh blades for direct laryngoscopy.26

Demonstration of the “crossed fi ngers” or “scissor” maneuver for opening the mouth with the thumb and middle fi nger of the right hand.

28

The laryngoscope blade is introduced into the right side of the opened mouth, and the tongue is pushed slightly to the left to move the tip of the blade into the midline.

30

Miller blades in assorted sizes.27

With the laryngoscope handle in the left hand, the blade is introduced at the right-hand corner of the mouth.

29

the “crossed fi ngers” or “scissor” maneuver with the thumb and middle fi nger of the right hand placed in the right-hand corner of the mouth (Fig. 28). The thumb is placed fi rmly against the lower teeth while the middle fi nger pushes upward on the upper teeth. This grip can also be used to gently extend the head. The laryngoscope with attached blade is taken in the left hand, which typically holds the handle at its distal third (Fig. 29). The laryngoscope blade is introduced into the right corner of the opened mouth and is moved into the midline, pushing the tongue to the left (Fig. 30).

Page 19: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 19

The tip of the blade is positioned above the epiglottis.31 By pulling gently on the laryngoscope handle, the intubator lifts the epiglottis and brings the glottis into view.

32

The laryngoscope should not be “levered,” as this could cause dental injury.

33 Ideally the tip of the endotracheal tube is in the middle third of the trachea, at an insertion depth of 21–23 cm from the incisor teeth.

34

At this point the epiglottis, a critical landmark, should come into view. When a curved Macintosh blade is used, the tip of the blade is advanced into the vallecula, or the depression between the base of the tongue and the epiglottis (Fig. 31). Exerting gentle traction along the axis of the laryngoscope handle will lift the epiglottis out of the sight line and bring the glottis into view (Fig. 32). The handle should always be pulled along its axis, never rotated or “levered” as this might cause

dental injury (Fig. 33). Next the prepared endotracheal tube is carefully advanced through the glottis under vision. We recommend advancing the tube down the right side of the mouth (retromolar route) so that the vocal cords can be kept in view. In all cases the cuff of the tube must be positioned within the trachea, and ideally the tube tip should be in the middle third of the trachea. The tube is typically inserted to a depth of 21 to 23 cm from the incisor teeth (Fig. 34).

Page 20: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine20

Verifi cation of Tube Placement After successful orotracheal intubation, the tube cuff is infl ated and correct tube placement is verifi ed. Unrecognized esophageal intubation is the most serious complication of endotracheal intubation. Table 7 lists typical reliable and unreliable signs of correct tube placement in the trachea.

Unreliable signs Reliable signs

Breath sounds on auscultation of the chest

Capnometry/capnography. This modality cannot detect unilateral bronchial placement or tube tip placement above the glottis

Absence of ventilation sounds on auscultation of the stomach

Intubation under vision (watching the tip of the tube pass between the vocal cords)

Rising and falling of the chest during ventilation

Bronchoscopy with positive identifi cation of the trachea (cartilage rings) and carina

Fogging in the tube Chest radiography(fi lms are often not available right away; the tip of the tube in adults should be 5 cm above the carina)

Pulse oximetry(fall of SaO2 is often delayed with misdirected intubation)

Esophageal detector devices

Table 7 Unreliable and reliable signs of tube placement in the trachea.

Bilateral auscultation of the chest in the axillary line (symmetrical breath sounds?) and auscultation over the epigastrium (no ventilation sounds?) should be performed after every intubation. Auscultation should not be omitted, as it can exclude placement errors such as a unilateral endobronchial position of the tube tip.

Besides the direct visual monitoring of tube insertion, the most reliable sign of endotracheal tube placement is end-tidal CO2 detection by capnography. This procedure is also explicitly recommended in the international guidelines of the European Resuscitation Council (ERC) after every endotracheal intubation37.

A capnometer allows for continuous, noninvasive monitoring of the carbon dioxide concentration in the expired air. The measured CO2 level is displayed in relation to the total gas mixture (in volume percent) or as an end-tidal partial pressure (etpCO2 in mm Hg). While capnography cannot trace the progression of CO2 values over the respiratory cycle (Fig. 35), it can provide a graphic display of the CO2 level at the end of each breath (Fig. 36).

The frequency of esophageal reintubation in critical care has a reported range between 1.3% and 9%6, 12, 32, 38, 39. These fi gures underscore the need for end-tidal CO2 monitoring during every intubation in critical care settings. On the other hand, it may be diffi cult for capnometry to confi rm correct endotracheal tube placement in patients who are in cardiac arrest. Due to the scant lung perfusion during chest compres-sions, only low end-tidal CO2 levels are measurable in this subset of patients. As a result, it is diffi cult to distinguish tracheal from esophageal intubation40.

Waveform displayed on a portable capnometer.35 Capnogram displayed on the Infi nity® Delta XL stationary patient monitor (Dräger Medical GmbH, Lübeck, Germany).

36

Page 21: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 21

Esophageal detection devices provide a reliable and cost-effective means of verifying tube placement (Fig. 37). The rubber bulb of the device is compressed, connected to the endotracheal tube, and released. The trachea, unlike the muscular esophagus, will not collapse in response to the bulb suction because it is stabilized by cartilage rings. If the tube is endotracheal, the bulb will reinfl ate; if it is in the esophagus, the bulb will not reinfl ate because it cannot aspirate air from the collapsing esophagus41. The bulb method is reliable in patients with or without a circulation but may be misleading in morbidly obese patients, in late pregnancy, severe asthma, and in the presence of heavy tracheal secretions. Under these conditions the trachea may also collapse in response to the negative pressure from the bulb42, 43.

At least one reliable sign of endotracheal tube placement should be detected after every endotracheal intubation. If a reliable sign is not found, the sum of the “unreliable” signs should all be consistent with endotracheal placement. If doubt exists, laryngoscopy or bronchoscopy should be repeated so that passage of the tube through the glottis or tracheal structures can be visualized.

Finally it should be noted that end-tidal CO2 detection, endo-tracheal intubation under vision, and esophageal detection devices are not 100% reliable in verifying tube placement. None of these methods can exclude the possibility of unilateral tube placement in a main bronchus.

Esophageal detection device with a self-infl ating bulb.37

Management of Diffi cult Direct Laryngoscopy If direct laryngoscopy is diffi cult or impossible on the fi rst attempt, various measures can be taken to improve visualiza-tion and intubation conditions (Table 8)4. An essential step is an early call for help from a physician experienced in airway management. The presence of an attending anesthesiologist is associated with a decreased overall incidence of complica-tions44. The airway care delivered by an experienced anesthe-siologist is distinguished not only by the type of care provided but also by the pharmacology of anesthesia induction.

It should also be emphasized that repeated intubation attempts are associated with higher complication rates. According to a study by Mort, the incidence of severe complications rises sharply when more than two failed intubation attempts are performed45. The incidence of severe hypoxia (SaO2 <80%) is increased by a factor of 14, aspiration by a factor of 4, and cardiac arrest by a factor of 7. The management of these cases should include the early conside ration of alternative airway techniques. The goal of airway management in most ICU patients is the placement of an endotracheal tube. But if direct laryngoscopy proves diffi cult or impossible, the intubator should not cling stubbornly to that procedure. It is better to switch to an alternative technique than risk additional airway trauma.

Measures for improving intubation conditions

Place the head in an optimum position(“sniffi ng” or modifi ed Jackson position)

Manipulate the larynx to align it more closely with the visual axis of the intubator:

� OELM (optimal external laryngeal manipulation) � BURP (backward upward rightward pressure on the thyroid cartilage)

Use an alternative introducer (e.g., gum elastic bougie)

Prebend the tube tip 90° on a stylet(“hockey stick” confi guration)

Use a video laryngoscope

Use alternative intubation blades(e.g., McCoy, Henderson blade)

Table 8 Measures that can improve intubation conditions.

Page 22: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine22

The C-MAC® Video Laryngoscope

Advances in digital photographic and video technology in recent years have led to the development of innovative laryngoscopes that differ from conventional devices by eliminating the need for a direct line of sight to the glottis (Fig. 38)7. Indirect visualization of the glottic plane is accomplished with a small digital camera that is mounted at the distal end of the laryngoscope blade and transmits the image electronically to an LCD video monitor (Fig. 39).

The C-MAC® video laryngoscope has a modular design that can accommodate various reusable stainless-steel blades with an integrated LED light source and camera. Macintosh blade sizes 2, 3, and 4 and Miller blade size 1 are currently available (Fig. 40). The Macintosh blades have been slightly modifi ed for use with the C-MAC®: The blades have a thinner profi le (maxi-mum 1.4 cm) and a beveled shoulder. They may be equipped with an optional guide channel for introducing a suction cath-eter to maintain a clear visual fi eld. The special “dBLADE®” is additionally available for diffi cult intubations (Fig. 41). Its distal tip has a 40° angulation that is designed to improve visualiza-tion of the glottis in anatomically diffi cult intubations.

The C-MAC® PM video laryngoscope, �; C-MAC® with Macintosh blade sizes 2–4, � – �; and C-MAC® with a Miller blade, �.

40 C-MAC® fi tted with a dBLADE® for diffi cult intubation.41

External 6.7-inch LCD monitor for the C-MAC® video laryngoscope, displaying the glottis.

42 The slot on the top of the LCD video monitor accommodates a standard SD memory card.

43

Unlike conventional laryngoscopy, video laryngoscopy can “see around the corner” (light blue area).

38 The glottis is displayed on the 2.4-inch LCD monitor of the C-MAC® PM video laryngoscope.

39

Page 23: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 23

The camera window is prewarmed by the LED light source to prevent fogging. The color image is transmitted by cable from the camera chip to a 6.7-inch (17-cm) diagonal external video monitor (Fig. 42). The monitor image always shows the tip of the blade, allowing for accurate placement of the blade tip in the vallecula. The C-MAC® video laryngoscope allows still pictures and video sequences to be recorded and stored digitally on an SD memory card (Fig. 43). Both the monitor and the laryngoscope handle have buttons that allow the operator to capture still images and video sequences. The system is powered by a rechargeable lithium ion battery that

allows approximately 2 hours of operation. Since the C-MAC® was designed for use under diffi cult conditions, the casing is made of impact-resistant plastic that protects against dust and splashes.

The C-MAC© Pocket Monitor (PM) that incorporates a 2.4-inch LCD screen (Fig. 44) is a part of the video airway manage-ment system that is available as an alternative to the larger monitor. This ultra-portable system is compatible with any KARL STORZ video laryngoscope blade. It can operate for approximately one hour without recharging. The small screen is for live viewing only and cannot capture stills or video.

Technique of Video Laryngoscopy

When the C-MAC® video laryngoscope is used with a Macintosh-type blade, intubation employs the same tech-nique as a conventional intubation. The system can be used for conventional direct laryngoscopy as well as video-guided laryngoscopy (Fig. 45). Combining a Macintosh-type blade with a camera at the blade tip makes the system more similar to direct laryngoscopy than other video laryngoscopes. Thus, the C-MAC® video laryngoscope makes it possible to perform conventional intubation under continuous guidance, which is advantageous for training and continuing education. Also, an assistant can monitor the effect of external laryngeal pressure and can actively apply suitable manipulations to

help optimize the glottic view (Fig. 46). As a rule, the view of the blade provided by video laryngoscopy is superior to direct visualization with a Macintosh blade46. Additionally, the modifi ed shape of the C-MAC® Macintosh blade allows the epiglottis to be carefully lifted on the tip of the blade, analogous to the technique with a straight Miller blade, to obtain a better view of the vocal cords47.

When the dBLADE® is used, the intubation technique must be modifi ed to accommodate the unique blade design (Fig. 47). As with most other video laryngoscopes that have an upturned blade tip (e.g., the GlideScope®, McGrath®), the dBLADE® is introduced in the midline for advancement toward the glottis. Analogous to direct laryngoscopy, the intubator

The 2.4-inch LCD monitor of the C-MAC® PM, shown here mounted on the dBLADE®.

44 The C-MAC® can be used for conventional direct laryngoscopy (�) as well as video-assisted laryngoscopy using the LCD monitor (�).

45

An assistant can observe the effect of external laryngealmanipulations and apply pressure as needed to optimize the glottic view.

46 Insertion of the dBLADE®.47

Page 24: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine24

With the dBLADE® in the oral midline, the tongue may hamper advancement of the tube.

48

The tracheal tube is prebent 90° on a malleable stylet (“hockey stick” confi guration) to facilitate endotracheal placement.

49 The endotracheal tube is introduced over a guide (e.g., Frova intubating stylet) preplaced under video laryngoscopic guidance.

50

should always try to identify the epiglottis so that the blade tip position can be assessed. This is done to ensure that the blade tip itself does not encroach upon the glottic inlet.

Due to the upward angulation of the dBLADE® tip, it is important to learn the proper use of the device. Studies with devices having a similar blade shape have shown that 5 to 8 intubations are necessary to become profi cient in the use of special blades48–51.

Although the glottic plane can be visualized by video laryngoscopy with a high success rate, problems may arise. Despite an excellent view, it may be diffi cult to direct the endotracheal tube through the vocal cords. This is true of all systems that do not have an integrated tube guide. With the blade positioned in the oral midline, the tongue may hamper advancement of the tracheal tube (Fig. 48).

In contrast to conventional laryngoscopy, the intubator does not require a straight line of sight from the oral cavity to the vocal cords7. Since it is unnecessary to align the oral, pharyngeal and tracheal axis, the tube must be advanced “around the corner.” Thus, whenever indirect laryngoscopy is performed with a device that does not have an integrated tube guide, endotracheal tube insertion should always be aided by a stylet53–55.

One study found that prebending the endotracheal tube 90° to a “hockey stick” confi guration on a malleable stylet allowed for easier endotracheal placement based on the subjective

assessment of the users (Fig. 49)53. This result is supported by a study on a simulated airway using the C-MAC® video laryngoscope and Macintosh blade54. When the tube was introduced on a stylet prebent to a 90° angle, the time to endotracheal intubation was shorter in all the simulated scenarios (normal airway, immobilized cervical spine, swollen tongue, and immobilized cervical spine plus a swollen tongue). Especially in scenarios with a very diffi cult airway (immobilized cervical spine plus a swollen tongue), intubation with the hockey-stick confi guration was faster and more successful than intubation without a stylet. A stylet prebent to a hockey-stick shape should defi nitely be used with all curved blades (including the dBLADE®) to facilitate accurate tube advancement to the glottic plane.

Another alternative is the primary video-laryngoscopic placement of a guide such as a gum elastic bougie or Frova intubating stylet. The tracheal tube is then advanced over the preplaced guide (Fig. 50)56, 57.

Other problems may arise even after the tube has passed through the vocal cords. For example, the extreme prebent confi guration of the stylet within the tube can make further tube advancement diffi cult. This often results from the fact that the tube is pointed toward the anterior part of the larynx (Fig. 51). In this case it may be helpful to advance the tube while simultaneously withdrawing the stylet. Rotating the tube 180° after removing the stylet may also help to advance the tip more deeply7, 53.

Page 25: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 25

An endotracheal tube prebent to a “hockey stick” shape points toward the anterior wall of the larynx.

51

Grade III and grade IV views in the Cormack-Lehane classifi cation.Grade III �, only the epiglottis is visible.

Grade IV �, no pharyngeal structures are visible.

52

The C-MAC® video laryngoscope can signifi cantly improve the glottic view in patients who have a diffi cult airway due to an immobilized cervical spine.

53

Glottic Visualization and Intubation Success with the Video Laryngoscope One study found that the use of a video laryngoscope with a Macintosh blade improved glottic visualization in 44% of patients compared with direct laryngoscopy (n=300)58. There were a few cases, however, in which video laryngoscopy gave a poorer view than direct laryngoscopy. Endotracheal intubation with the video laryngoscope was not possible in a total of 4 patients (1.3%). In another study of patients whose glottis could not be visualized by direct laryngoscopy (CL grade III or IV, Fig. 52), the monitor of the video laryngoscope provided an improved glottic view in 84% of the cases46. The incidence of diffi cult intubation was reduced from 14% to 3% in this study. The KARL STORZ video laryngoscope was also found to improve glottic visualization in patients with anticipated diffi cult intubation59, although this study did not include cases with a CL grade IV view (epiglottis and glottis not visible). The incidence of CL grade III (only the epiglottis is visible) was lower compared with conventional laryngoscopy, and 99% of the patients could be successfully intubated by video laryngoscopy. These data clearly indicate that the use of a video laryngoscope can improve visualization of

the glottic plane in most patients. As a result, use of the C-MAC® with Macintosh blade can be recommended for every intubation that is performed outside the operating room.

In patients with a simulated diffi cult airway involving limited cervical spine motion and limited mouth opening due to the placement of a cervical immobilization collar, use of the C-MAC® video laryngoscope could signifi cantly improve the view of the glottis (Fig. 53)60. The vocal cords were visible by direct laryngoscopy in 30% of cases, while use of the C-MAC® video laryngoscope with Macintosh blade provided a clear view of the glottis in 86% of the patients. External laryngeal manipulation (BURP maneuver) improved the glottic view in 95% of cases.

In our own study, the C-MAC® video laryngoscope with Macintosh blade was used in patients with unanticipated diffi cult intubation (CL grades III and IV) as an alternative to direct laryngoscopy61. The C-MAC® with Macintosh blade improved visualization of the vocal cords in 94% of the patients. It did not improve the glottic view in 6%. Tracheal intubation was successful in 94% of patients using the C-MAC® video laryngoscope. These cases required a maximum of three intubation attempts.

Page 26: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine26

No large clinical studies have yet been done on the use of the curved dBLADE® for diffi cult airways. In one study of 20 patients with diffi cult laryngoscopy in which the glottis was not visible (CL grades III and IV), use of the dBLADE® was found to improve visualization in every case (to CL grade I or II)47. Intubation was successful in 14 patients on the fi rst attempt. The remaining six patients required a maximum of four additional attempts for successful intubation. The high-curvature dBLADE® is particularly intended for use on the unanticipated diffi cult airway. Studies of video laryngoscopes with a similar blade shape found improved visualization in almost all patients with diffi cult direct laryngoscopy7, 62. The McGrath® Series 5 and GlideScope® had success rates of 94–95% in cases of failed direct laryngoscopy with a conven-tional Macintosh blade.

Video Laryngoscopy in Critical Care Medicine Endotracheal intubation is considerably more diffi cult in critical care settings than in the structured routines of an operating room. Complications during airway management are common. Given these circumstances, it should be assumed that every critically ill patient in ICU who requires endotracheal intubation will have a diffi cult airway. Previous studies on video laryngoscopy have shown conclusively that the use of a video laryngoscope with a Macintosh-type blade is justifi ed for every intubation in critical care medicine in order to protect patients from potential hazards.

An optimum video laryngoscope must meet the specifi c requirements of an ICU setting:

Use of the C-MAC® video laryngoscope with a Macintosh video blade in the ICU was able to reduce the incidence of diffi cult intubation from 20% with direct laryngoscopy to 7% with the C-MAC®63. Use of the C-MAC® also resulted in more successful intubations on the fi rst attempt (88%) compared with direct laryngoscopy (80%).

� Rapid accessibility without the complicated assembly of components.

� Rugged construction. Dropping the device, which may well occur in an emergency setting, should not cause signifi cant damage.

� Easy to use, with a short learning curve. � Flexibility of use. The device should be usable in a range of patients; various blade sizes and types should be available.

� A large monitor. This will allow all members of the intensive care team to observe the intubation and, if necessary, render assistance with minimal communication (e.g., laryngeal manipulation).

� Fast and effective reprocessing. The multitude of multidrug-resistant organisms that exist in critical care settings makes it imperative to achieve a thorough decontamination.

Supraglottic Airway Devices

Profi ciency with alternative techniques of oxygenation andventilation is of critical importance when endotracheal intubation fails. Supraglottic airway devices have gained an established role as alternative methods for securing a diffi cult airway in prehospital emergency medicine and anesthesiology4, 37. To date, supraglottic techniques have been used only sporadically in critical care medicine64. A British study on the availability of airway equipment in ICUs found that only about 50% of the care units were equipped with supraglottic airway devices26. The main reason for this is the need to ventilate critically ill patients invasively and for an extended period, which generally can be accomplished only with an endotracheal tube. Moreover, intensivists with no background in anesthesiology often lack the clinical experience and training necessary to use the devices safely and effectively. On the other hand, intensive training with supraglottic devices and a protocol based on standard guidelines and algorithms will enable practitioners to recognize typical airway problems quickly and institute appropriate measures without delay.

In principle, supraglottic airway devices provide an alternative to face-mask ventilation and endotracheal intubation (Table 9). Because they do not pass through the glottis, the DGAI also refers to them as “pharyngeal airway devices”4.

Supraglottic airway devices Examples (see Fig. 54)

Classic laryngeal masks � Ambu AuraOnce (�) � LMA Classic

Laryngeal masks with an esophageal lumen

� LMA Supreme (�) � LMA ProSeal®

� I-Gel® (�)

Laryngeal masks thatallow blind endotracheal intubation

� Fastrach intubating LMA (�)

Devices with an esophageal and oropharyngeal cuff

� Combitube � EasyTube (�) � LTS-D laryngeal tube (�)

Table 9 Typical supraglottic airway devices.

Even less experienced and novice users can successfully use these devices for ventilation and oxygenation with little training. In one study, 50 subjects with no experience in endotracheal intubation were trained in the use of the LMA Supreme® laryngeal mask on an airway manikin65.

Page 27: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 27

In the next phase the participants inserted the laryngeal mask in anesthetized patients. All 50 subjects were able to place the laryngeal mask successfully, and 86% required only one attempt.

The LTS-D laryngeal tube was successfully inserted by novice users in 74% of anesthetized patients within 45 seconds66. In another study, fi rst-month anesthesia residents were trained briefl y in ProSeal® laryngeal mask airway insertion on a manikin and were then able to place the LMA in patients with a higher success rate than conventional laryngoscopic intubation (100% versus 65%) and with a shorter effective airway time (42 s versus 89 s)67. Similar data were reported for LTS laryngeal tube insertion in an airway manikin: the LTS could be placed faster and with a higher success rate compared to endotracheal intubation68. In a large study the Combitube could be placed successfully on the fi rst attempt in 82% of cases69.

In summary, these data indicate that all supraglottic airway techniques are easy to learn. It should be emphasized, however, that training on an airway simulator and on patients is essential before the devices can be used safely and profi ciently.

Especially in critical situations involving failed intubation in the ICU, supraglottic airway devices can provide temporary oxygenation and ventilation until a physician experienced in airway management is available. The guidelines of the European Resuscitation Council (ERC) recommend that personnel who lack experience in endotracheal intubation should use a supraglottic airway device as an alternative37. The Combitube, classic laryngeal mask, laryngeal tube, and

I-gel® supraglottic airway are specifi cally recommended for the ventilation of patients in cardiac arrest. It should be noted, however, that none of the supraglottic devices is a cure-all and none can establish ventilation and oxygenation in every situation.

While many of the supraglottic devices can be placed blindly, they do not allow the airways to be inspected for trauma, bleeding, foreign bodies, or other pathology. As a general rule, all supraglottic techniques are contraindicated in patients who have upper airway pathology that involves severe swelling (e.g., acute infl ammatory diseases such as epiglottitis) or large tumors. On the other hand, these contraindications should be considered relative in situations where there have already been multiple failed attempts at endotracheal intubation.

None of the aforementioned devices may be considered a substitute for endotracheal intubation. Instead, supraglottic airway devices should be considered a temporizing measure in critical care settings72. While it is true that ventilation can often be achieved, a supraglottic airway cannot effectively protect against aspiration. The general aspiration risk during ventilation with a classic laryngeal mask is reported to be 1:5000 in routine anesthesiologic practice70. The laryngeal mask signifi cantly reduces the risk of aspiration compared with conventional bag-and-mask ventilation71.

Once oxygenation and ventilation have been established, an individual decision can be made on how best to secure a defi nitive airway. In principle, this can be accomplished by creating a surgical airway or by fl exible endoscopic intubation. An ENT surgeon, for example, can easily perform an elective tracheotomy while a supraglottic device is in place.

Ambu AuraOnce (�), LMA Supreme (�), I-gel® airway (�), Fastrach intubating LMA (�), EasyTube (�), LTS-D laryngeal tube (�).54

� �

Page 28: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine28

The blind insertion of an endotracheal tube through a classic laryngeal mask has a low success rate. It is recommended, therefore, that secondary intubation be performed with a fl exible intubation endoscope73. First, a fl exible intubation rod (e.g., Aintree intubating catheter) is positioned within the trachea. Then, the laryngeal mask is removed and the endotracheal tube is introduced over the intubation rod (Fig. 55)74. When a Mainz adapter is used, ventilation of the patient can be continued during placement of the rod (see also Flexible Endoscopic Intubation).

Once a fl exible intubation rod has been placed, the laryngeal mask can be removed and an endotracheal tube can be introduced over the rod.

55

The head is tilted back and the laryngeal mask is inserted along the hard palate into the pharynx.

56

Laryngeal Masks

Classic Laryngeal Mask Since fi rst described in 198575, the laryngeal mask airway has been utilized throughout the world in a variety of anesthetic procedures. According to its inventor, the laryngeal mask is intended to provide a hybrid technique between mask anesthesia and endotracheal anesthesia.

The laryngeal mask has a cuff that seals off the space around the epiglottis from the posterior side, thus enabling the patient to be ventilated without passing a tube through the glottis. The distal tip of the cuff should engage against the upper esophageal sphincter.

With some experience, the user can manually place the laryngeal mask swiftly and without additional aids. As in anesthesia induction before endotracheal intubation, the patient must be anesthetized or deeply unconscious. The ideal head position is the sniffi ng or modifi ed Jackson position. One way to place a laryngeal mask is to open the patient’s mouth, tilt the head back (Fig. 56), and advance the device along the hard palate into the pharynx. When the tip of the mask engages the upper esophageal sphincter, a defi nite resistance will be felt, which confi rms correct placement.

Many airway algorithms rank the laryngeal mask as an alternative device to be used in cases of failed intubation or diffi cult face-mask ventilation76, 77. It should be noted, however, that during the ventilation of a patient with a classic laryngeal mask (e.g., Ambu AuraOnce, LMA Unique), gas leak often occurs at airway pressures of approximately 18–20 cm H2O or higher78, 79. This limits the quality of ventilation that can be achieved in patients with low pulmonary or thoracic compliance.

Page 29: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 29

I-gel® single-use supraglottic airway with drainage channel.57 LMA Supreme® single-use laryngeal mask with esophageal lumen.58

Laryngeal Masks with an Esophageal Lumen A recent development is laryngeal masks with a separate lumen that connects directly to the esophagus. This provides access for various actions such as inserting a gastric tube after successful placement of the laryngeal mask. The airway and esophagus can be separately ventilated and drained through the extra lumen. This signifi cantly reduces the risk of aspiration. Three laryngeal masks with an esophageal lumen are currently available:

In one clinical study, the I-gel® laryngeal mask was success-fully placed on the fi rst attempt with a success rate of 78%80. The I-gel® was correctly placed in all anesthetized patients after a maximum of two additional attempts. The airway leak pressure in the I-gel® group was reported to be 27 cm H2O. In another study the I-gel® laryngeal mask was successfully placed on the fi rst attempt in 83% of cases81. It was correctly placed after 3 attempts in 95% of cases and could not be

� The I-gel® is a single-use, uncuffed laryngeal airway made of a gel-like material (Fig. 57). The laryngeal part conforms to the anatomy of the hypopharynx and has a drainage channel that permits the insertion of a thin gastric tube.

� The LMA ProSeal® is a reusable laryngeal mask with an extra lumen for a gastric tube. It has a modifi ed cuff designed to create a better seal than the classic LMA Unique®.

� The LMA Supreme® is a single-use laryngeal mask with an esophageal lumen. It has an anatomical shape designed for easier placement (Fig. 58). Like the ProSeal®, it reportedly creates a better airway seal than the classic laryngeal mask.

successfully placed in 5% of the patients. In all, 50% of theI-gel® laryngeal masks produced an airtight seal at a ventilation pressure of 20 cm H2O. No signifi cant difference in airway leak pressures was found between the I-gel® device and the classic laryngeal mask (LMA Unique®): 25 vs. 22 cm H2O82.

The I-gel® laryngeal mask was successfully used for the ventilation of a patient with failed intubation (CL grade III)83. Also, a thin endotracheal tube was passed into the trachea through the laryngeal mask under fi beroptic guidance.

The LMA Supreme® and LMA ProSeal® were correctly placed on the first attempt with a high success rate (92–95%) in anesthetized patients84. The same study found airway leak pressures of 29 cm H2O for the LMA ProSeal® (cuff pressure 45 cm H2O) and 26 cm H2O for the LMA Supreme® (cuff pressure 65 cm H2O). Gastric tube insertion was successful in all cases.

In one case report, the LMA Supreme® laryngeal mask was successfully used for ventilation, oxygenation, and drainage of gastric contents in a critically ill, nonfasted patient with a diffi cult airway (CL grade III)85. The LMA ProSeal® was also used successfully in two patients with an unanticipated diffi cult airway as an alternative to endotracheal intubation (airway edema with CL grade III and failed intubation in an obese patient with CL grade III)86.

In principle, the ICU should always be equipped with the type of laryngeal mask with which personnel have had the most clinical experience.

Available data indicate that the LMA Supreme® and ProSeal® allow for higher ventilation pressures and easier placement than the I-gel® laryngeal mask.

Page 30: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine30

Laryngeal Masks for Endotracheal Intubation The Fastrach intubating laryngeal mask airway (ILMA) is an advanced version of the classic laryngeal mask. The Fastrach is specially designed for endotracheal tube placement and permits a special spiral-wound tube with a soft silicone tip to be passed blindly through the vocal cords (Fig. 59).

One feature that distinguishes the ILMA from a classic laryngeal mask is its shortened, rigid shaft. The shaft, or airway tube, is curved at almost a 90° angle and conforms to the anatomy of the pharynx. Attached to the shaft is a rigid handle (Fig. 60, �). A small rubber lip, called the epiglottic elevating bar, is automatically raised during endotracheal tube insertion and, when the ILMA is correctly positioned, enables the spiral tube (up to size 8.0 I.D.) to enter the trachea (Fig. 60, �).

The ILMA is available in sizes 3–5 for patients with a body weight of 30–100 kg. Unlike other laryngeal masks, the ILMA is designed mainly for use in anticipated or unanticipated diffi cult airway situations.

An important advantage of the ILMA is the ability to carry out a two-step procedure in emergency patients. In the fi rst step the ILMA is placed much like a classic laryngeal mask to oxygenate and ventilate the patient. In the second step the trachea can be intubated via the ILMA if necessary. But if problems arise during advancement of the tracheal tube, the tube can be withdrawn while ventilation of the patient is continued.

Various studies have been published on the successful use of the ILMA. Medical students inexperienced in the use of laryngeal masks were able to place the ILMA faster than a classic laryngeal mask and achieved adequate ventilation with a higher success rate87. Tracheal intubation via the ILMA was successfully completed by 67% of the participants. In another study, inexperienced participants were able to ventilate anesthetized patients faster with an ILMA than

by bag-and-mask ventilation (36 s versus 44 s) and with a higher success rate (98% versus 86%)88. Also, endotracheal intubation was successful more often with the ILMA (92%) than with conventional direct laryngoscopy (40%). In patients with a diffi cult airway, experienced anesthesiologists were able to place the ILMA with an 89% success rate on the fi rst attempt89. Ventilation was accomplished in three attempts or fewer in all patients. The success rate for blind intubation through the ILMA was 97%. The remaining patients were successfully intubated under fi beroptic guidance. In a European multicenter study, blind intubation through the ILMA was accomplished in 96.2% of cases after a maximum of three attempts90.

Successful use of the ILMA has also been documented in patients with known airway access diffi culties such as decreased mouth opening, limited cervical spine motion, or an unanticipated diffi cult airway91.

Airway leak has been described with the ILMA at peak ventilation pressures of 24–27 cm H2O92, 93. Currently there are no data on the incidence of aspiration with the ILMA compared with endotracheal intubation. In one published case, aspiration occurred during the use of an ILMA in a patient with a previously unknown axial hiatal hernia94.

Use of the ILMA is limited in patients with upper airway abnormalities such as tumors, abscesses, or foreign bodies, because additional airway injury cannot be ruled out in this “blind” intubation technique91.

Owing to its ease of placement in the pharynx, reasonably good airway seal during ventilation, and the added option of semi-blind endotracheal intubation, the ILMA provides an effective alternative for failed intubation cases. Even in this application, however, the ILMA should not be used as an “ad hoc” rescue device for emergencies. It should be used only after adequate training and practice in an unhurried atmosphere.

Special spiral-wound endotracheal tube with a soft silicone tip, used with the Fastrach intubating laryngeal mask airway (ILMA).

59 The Fastrach intubating laryngeal mask airway (ILMA).60

Page 31: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 31

Functional principle of the esophagotracheal double-lumen airway (Combitube).

61

Devices with an Esophagealand Oropharyngeal Cuff

Combitube The Combitube consists of a cuffed, double-lumen tube. Onelumen resembles a conventional endotracheal tube with a distal cuff. The other lumen is closed at its distal end, has multiple side openings, and has a proximal cuff at the level of the oropharynx that seals the oronasal airway (Fig. 61)95. The dual-lumen design allows for ventilation after either esophageal or endotracheal placement.

The Combitube is classifi ed as a backup device for use on unanticipated diffi cult airways and especially in cannot intubate-cannot ventilate scenarios. It can secure the airway and provide rapid oxygenation and ventilation in emergency settings despite diffi cult anatomy, unfavorable lighting, a confi ned space, and limited equipment96.

The Combitube is available in two sizes – 37 F-SA (“small adult”) and 41 – and can be used in patients who are at least 122 cm tall. Whenever possible it should be placed under direct vision with the aid of a laryngoscope to reduce the risk of injury97. The Combitube can also be placed semi-blindly. This is done by opening the mouth, lifting the lower jaw by the Esmarch maneuver, and passing the Combitube into the pharynx96. Two markings on the tube shaft indicate the correct insertion depth.

In more than 95% of cases the tip of the blindly inserted Combitube will enter the esophagus, and therefore initial ventilation is delivered through the longer, blue lumen following blind insertion. With positive end-tidal CO2 detection and positive auscultation of the lungs, ventilation is simply continued through that lumen, which has side openings at the level of the larynx. The transparent limb can be used to pass a gastric tube into the esophagus or stomach.

In the event of negative end-tidal CO2 detection and lung auscultation, ventilation can still be provided through the shorter, transparent lumen without repositioning the Combitube. Positive auscultation and CO2 detection will con-fi rm that the distal end of the tube has entered the trachea.

When placed in the esophagus, the Combitube produces an effective airway seal up to a ventilation pressure of approximately 40 cm H2O. It should be noted, however, that this can be achieved only with a very high pharyngeal cuff pressure greater than 250 cm H2O98. Owing to its tight seal, the Combitube can also be used during cardiopulmonary resuscitation without having to interrupt chest compressions for ventilation99.

In one study the Combitube was successfully placed on the fi rst attempt in 82% of 1594 patients in cardiac arrest69. Seven percent of the patients could not be ventilated even with multiple attempts, however. In anesthetized patients, the Combitube was successfully placed on the fi rst attempt in 84% of cases98. Adequate ventilation could not be achieved in 10% of the patients, even with multiple attempts.

The Combitube can secure the airway without manipulation of the cervical spine. The technique can be quickly learned, especially by personnel inexperienced in endotracheal intubation100.

Obstruction of the side openings by mucosa can hamper or prevent ventilation101. Another limitation is the material used: Because the cuffs contain latex, the Combitube cannot be used in patients with a latex allergy. Relative contraindications exist in patients with intact bite or swallowing refl exes. The tube should not be used without laryngoscopic visual guidance in patients with diseases of the esophagus or after the ingestion of caustic substances.

Page 32: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine32

EasyTube

The EasyTube (EzT) was developed for in-hospital and prehospital use in all patients with an anticipated or unanticipated diffi cult airway. It permits the oxygenation and ventilation of patients who are trapped in wreckage or diffi cult to reach. It is also recommended in cases where direct laryn-goscopy is diffi cult or impossible due to bleeding or vomiting.

The EzT is a single-use device that combines the basic features of an endotracheal tube with those of a supraglottic airway device102. It is available in two sizes, 28 and 41 Ch, and can be used in patients at least 90 cm in height. The principle of the EzT is analogous to that of the Combitube: It is a double-lumen tube that can provide ventilation when placed in either the trachea or the esophagus. The large proximal cuff seals the oropharyngeal and nasopharyngeal airways. The single distal lumen of the tube is equivalent to a standard endotracheal tube with an inner diameter of 7.5 mm (41 Ch) or 5.0 mm (28 Ch) (Fig. 62).

Compared with the Combitube, the esophageal and tracheal lumens of the EzT are shaped much like an endotracheal tube. Even when the distal tip of the tube is positioned in the esophagus, the trachea is still accessible through the second lumen (Fig. 63). The EzT allows the passage of a fl exible endoscope into the trachea, permitting an exchange for a defi nitive endotracheal tube.

After primary direct laryngoscopy and tracheal placement (Fig. 64), the patient is ventilated through the clear-colored lumen. If direct laryngoscopy and endotracheal intubation are not possible, the tip of the EzT can be placed in the esophagus blindly or under visual control with a laryngoscope. In this case the patient can be ventilated through the shorter, blue-colored lumen.

In a study comparing the EzT with direct laryngoscopy in anesthetized patients, the EzT could be placed faster and more easily103. The initial placement attempt was successful in 95% of the patients. With both the EzT and endotracheal tube, airway leak occurred at a ventilation pressure of 35 cm H2O. When used in prehospital settings, the EzT achieved a high success rate in the ventilation of diffi cult airways104. In a clinical comparison with the laryngeal tube and LMA ProSeal® laryngeal mask, the EzT was successfully placed on the fi rst attempt in 41% of cases (versus 82% for the laryngeal tube and 68% for the LMA ProSeal®)105. The EzT had a reported cuff pressure of 320 to 350 mm H2O when infl ated with70–90 mL of air. Cuff leak occurred at ventilation pressures of 18–22 mm H2O in this study.

As with the Combitube, relative contraindications exist in patients with intact bite or swallowing refl exes. Laryngoscopic placement under vision is particularly indicated in patients with diseases of the esophagus or after the ingestion of caustic substances. Due to its rigid construction, upper airway trauma cannot be ruled out during use of the device.

The EzT combines the basic features of an endotracheal tube with those of a supraglottic airway device.

62 With the EzT in place, an endoscope can be passed into the trachea to enable the placement of an endotracheal tube.

63

After direct laryngoscopy and tracheal placement of the EzT, the patient is ventilated through the clear-colored lumen.

64

Page 33: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 33

The laryngeal tube (LT) consists of a single-lumen tube with an oropharyngeal and esophageal cuff.

65

Color markings on the infl ation syringe correspond to theconnector of the laryngeal tube, ensuring that the cuff can be quickly infl ated to the proper air volume in an emergency.

66

Laryngeal Tube The laryngeal tube (LT) consists of a single-lumen tube with a larger oropharyngeal cuff and smaller esophageal cuff (Fig. 65). The proximal end of the tube is fi tted with a color-coded standard connector. The color of the connector depends on the size of the LT. The distal esophageal end is closed and fi tted with a low-pressure cuff. The oropharyngeal cuff seals off the upper airways, allowing respiratory air to fl ow through the anterior opening toward the blade. Both cuffs are infl ated simultaneously with a large syringe after placement. Color markings on the infl ation syringe match the color of the LT connector so that even in an emergency, the cuff can be quickly infl ated with an air volume appropriate for the size in use (Fig. 66). The reusable LT is made of silicone, and the disposable version is made of polyvinylchloride.

It is recommended that the patient’s head be placed in a modifi ed Jackson position for successful placement of the laryngeal tube. The cuff of the LT should be completely defl ated and well lubricated. The mouth is opened, the head is tilted back, and the laryngeal tube is inserted in the midline along the hard palate and into the pharynx until a slight resistance is felt. The middle black line on the tube should be between the upper and lower teeth (Fig. 67). Correct placement is verifi ed by end-tidal CO2 detection and lung auscultation. The cuff pressure should not exceed a value of 60 cm H2O106.

The LT can be placed with a high initial success rate of 97–100%107. Ease of placement is similar to that of a laryngeal mask. The airway leak pressure of the LT is reported to be2 cm H2O higher than that of a classic laryngeal mask (laryngeal mask: 18–20 cm H2O, LT: 20–22 cm H2O). This difference is probably not relevant in clinical use, however. In a comparative study the LT was placed on the fi rst attempt as successfully as the LMA ProSeal®108, although fi ve patients could not be successfully ventilated with the LT. Both devices produced a comparable airway seal. The placement of the LT had to be repeatedly adjusted and optimized, however. The LMA ProSeal® achieved a higher tidal volume than the LT at equal ventilation pressures. In another comparative study, the LT could not be optimally placed in two patients109. Again, both devices were found to have comparable airway leak pressures (24 cm H2O for the LT, 26.5 cm H2O for the ProSeal®).

Compared with the classic laryngeal mask airway, the LT protects better against aspiration owing to its distal esophageal cuff. To date, no instances of aspiration have been reported during routine use of the LT.

As with the laryngeal mask, an intubation catheter can be passed through the ventilation lumen of the LT under fi beroptic guidance, and an endotracheal tube can be advanced over the catheter into the trachea110.

The LT permits oxygenation and ventilation in patients with previous failed attempts at endotracheal intubation. The LT was used with a high success rate (97%) after failed

Successful placement of the LT: The middle black line on the shaft is between the upper and lower teeth.

67

prehospital endotracheal intubation111. The authors conclude that the LT provides a reliable rescue device when intubation has failed. The LT can also be used as an initial airway in emergency settings by rescuers less experienced with endotracheal intubation.

Page 34: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine34

The LT also provides an alternative to face-mask ventilation. Paramedics working in cardiac arrest situations could successfully insert the LT on the fi rst attempt in 90% of all cases112. Ventilation could be performed in 95% of the resuscitations. In another study, ventilation was performed exclusively with an LT during cardiopulmonary resuscitation by rescuers instead of bag-and-mask ventilation113. It was found that effective ventilation could be provided after successful placement.

The LTS has a second lumen allowing the insertion of a gastric tube.68

One disadvantage of the LT is the inability to drain the stomach through a gastric tube. Also, a mouth opening of approximately 2.3 cm is required to introduce the shaft into the oral cavity. The cuffs are both large and thin-walled and may tear on sharp teeth, for example, during placement 114.

Relative contraindications to use of the LT exist in patients with intact bite or swallowing refl exes.

Laryngeal Tube Suction (LTS) The LTS is an advanced version of the LT. It has a second lumen that allows for decompression of the esophagus in case of regurgitation and provides access for inserting a gastric tube (Fig. 68). The esophageal drainage tube additionally reduces the risk of aspiration.

The LTS has been used repeatedly and successfully in critically ill patients, seriously injured patients, and in the of cardiopulmonary resuscitation115, 116.

Flexible Endoscopic Intubation

Flexible endoscopy is a widely used technique for endo-tracheal intubation in both unanticipated and anticipated diffi cult airways (see Predictors of a Diffi cult Airway). In a classic fl exible endoscope (also called a “fi berscope”), optical fi ber bundles extend to the eyepiece for image transmission and toward the distal end for light transmission, accompanied by defl ection control elements (Fig. 69). Recent developments include endoscopes that employ CMOS (complementary metal oxide semiconductor) sensor technology for imaging, so that the terms “fi beroptic” and “fi beroptic intubation” are no longer applicable to these endoscopes117.

Diagram illustrating the components of a classic fl exible endoscope.69

Kink guard

Control lever

Wire guide

Wire guide

Test valve

Light post

Gears

Drive train

Eyepiece

Control wires

Nevertheless, the terms “fl exible endoscopic intubation” and “fi beroptic intubation” still refer to the same technology and can be used interchangeably.

Few contraindications exist to fl exible endoscopic intubation. They include all airway strictures and stenoses that cannot be crossed with the endoscope and endotracheal tube. Also, vision may be obscured due to blood or secretions. When active bleeding is present, key landmarks generally cannot be identifi ed, resulting in a failed intubation.

In principle, intubation with a fl exible endoscope can be performed by either the nasal or oral route. Nasal intubation is technically easier because usually the epiglottis and glottis are more easily visualized after the scope passes through the nasopharynx118. The fl exible endoscope can be used through either access route (oral or nasal) in the awake or anesthetized patient.

Page 35: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 35

Flexible Endoscopic Intubation in the Awake Patient Flexible endoscopic intubation of the awake patient is the procedure of fi rst choice for an anticipated diffi cult airway4. Spontaneous breathing is preserved, allowing the patient to remain oxygenated until the endotracheal tube is placed.

The procedure is explained to the patient, and informed consent is obtained. A cooperative patient during intubation is a key factor in completing a successful procedure. Initial topical anesthesia of the airways is indicated to blunt protective refl exes (coughing, gagging) and make the procedure more comfortable for the patient.

The success of this procedure depends greatly on the preparation of the patient and the necessary materials. In contrast to laryngoscopy, accurate positioning of the patient is not strictly necessary119, although the upper body of an ICU patient should be elevated to support spontaneous breathing.

The fi rst procedural step in awake nasotracheal intuba-tion is to place nose drops into both nostrils (Table 10). Nose drops containing a local anesthetic (e.g., lido-caine 3%) plus a vasocon-strictor (e.g., phenylephrine 0.25%) can desensitize the nasal mucosa and also pre-vent bleeding during intuba-tion120 (Fig. 70). The operator should wait approximately 2–5 minutes for the agents to take effect before introducing the endoscope121.

Nose drops with a local anesthetic and vasoconstrictor.

70

Oxygenation is administered through a nasal cannula in the contralateral nostril.

71

Basic protocol for awake endoscopic intubation

1. Secure informed consent

2. Administer nose drops containing a vasoconstrictor and local anesthetic (wait 5 minutes!)

3. Oxygen administration

4. Conscious sedation (e.g., remifentanil at 0.1–0.5 μg/kg/min)

5. Visualize the glottic plane and apply local anesthetic to the glottis; wait for onset of anesthesia

6. Insert the endoscope into the trachea and apply local anesthetic. Retract above the glottic plane, wait for onsetof anesthesia

7. Reinsert the intubation endoscope into the trachea, and advance the endotracheal tube over the endoscope

8. Proceed with general anesthesia

Table 10 Basic protocol for awake endoscopic intubation.

Oxygenation during Flexible Endoscopic Intubation Immediately after the nose drops are administered, oxygen should be insuffl ated via nasal cannula (approximately 4 L/min) (Fig. 71). With an ICU patient who is hypoxic or at risk for hypoxia, noninvasive ventilation can also be performed during fl exible endoscopic intubation122.

Page 36: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine36

A snug-fi tting CPAP mask or ventilation mask can be used with a Mainz adapter placed between the mask and ventilation hose (Fig. 72). This adapter allows continuous oxygenation and ventilation to be maintained during endo-scopic intubation. The mask can be secured to the face and head with fl exible straps (Fig. 72, �).

Another option is to use an endoscopy face mask (Fig. 73), although this type of mask is diffi cult to secure to the patient’s head. When an endoscopy mask is used, an assistant should be delegated to hold the mask in place on the patient’s face.

Intubating the patient through a face mask requires a user experienced in endoscopic intubation. The advantage is the ability to ventilate the patient on as much as 100% oxygen during the procedure. Another option is to provide noninvasive positive-pressure ventilation (NPPV) during intubation. Ventilatory parameters of CPAP 4 cm H2O, PSV 17 cm H2O, and FiO2 1.0 during bronchoscopy in NPPV-ventilated patients have been described as adequate parameters122.

Patient Sedation Generally sedation should enable the patient to tolerate the procedure well while still allowing spontaneous breathing. Low doses are suffi cient in hypoxic, critically ill patients. Short-acting benzodiazepines (e.g., midazolam 0.03–0.05 mg/kg)combined with opioids (e.g., fentanyl 1–1.5 μg/kg) have been successfully used for sedation, anxiolysis, and analgesia123. The use of an opioid also has the side effect of suppressing airway refl exes during endoscopic intubation. Remifentanil administered by infusion pump has also been successfully used for sedation and analgesia during awake endoscopic intubation (0.1–0.5 μg/kg/min)124. The use of remifentanil was characterized by good patient tolerance with high hemodynamic stability. Ketamine (0.2–0.5 μg/kg) may also be administered instead of an opioid125. Ketamine combined with midazolam permits adequate spontaneous breathing without circulatory depression while providing good analgesia and sedation.

An anti-fogging agent is applied to the lens.74 Lubricant is applied to the endoscope shaft before insertion.75

Alternatively, an endoscopy mask can be used for simultaneous oxygenation and ventilation.

73

Placed between the ventilation hose and mask, the Mainz adapter enables continuous oxygenation and ventilation during endoscopic intubation.

72

Page 37: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 37

Flexible Nasotracheal Endoscopic Intubation The lens should always be pretreated with an anti-fogging agent before the endoscope is used (Fig. 74). We also recommend applying a lubricant (e.g., silicone oil) to the endoscope shaft (Fig. 75). This is necessary so that the endotracheal tube can be easily advanced over the endoscope shaft following successful placement of the endoscope. Before the endoscope is inserted into the nose, an endotracheal tube with its cuff defl ated is loaded onto the endoscope shaft and secured (Fig. 76). Spiral-wound tubes have proven excellent for endoscopic intubation owing to their fl exibility, atraumatic tip, and kink resistance in routine anesthesiologic use125. The inner diameter of the endo-tracheal tube should be at least 1.5 mm larger than the outer diameter of the fl exible endoscope. At the same time, the inner diameter should not be too large relative to the selected fl exible endoscope, as this could lead to problems during tube placement.

Nose drops can be administered for initial topical anesthesia of the nasal mucosa, and the pharynx can be anesthetized with lidocaine spray (Fig. 77).Before the endoscope is inserted, both nostrils are inspected and the larger opening is used for intubation (Fig. 78). As the endoscopeis passed into the nostril, the inferior meatus is identifi edas it will be the route forendoscope insertion (Fig. 79). Before the endoscope is inserted into the nose, an endotracheal

tube with defl ated cuff is loaded onto the endoscope shaft and secured.

76 lidocaine pump spray.77

The larger nostril opening is used for intubation.78 The inferior meatus is identifi ed.79

Page 38: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine38

Oropharynx with uvula

Glottis

Tab. 11 Anatomic landmarks for nasal endoscopic intubation. Bifurcation (�).

Epiglottis

Trachea

The endoscope should never be advanced blindly as this could cause airway bleeding and injuries. A key to successful intubation is the identifi cation of landmarks on the way to the trachea (Table 11). If orientation is lost, the endoscope should be slowly retracted until an anatomic landmark can be positively identifi ed. After the scope has passed through the choana and nasopharynx, the epiglottis is identifi ed as the fi rst key anatomic landmark (�). The tip of the endoscope is now positioned just outside the glottis (landmark) (�). It may be helpful at this point to ask the patient to protrude the tongue and inhale deeply. This maneuver mobilizes the base of the tongue from the posterior pharyngeal wall and often improves visualization of the vocal cords.

Page 39: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 39

The next step is topical anesthesia of the vocal cords: 2 mL of lidocaine 2% is applied to the glottis through the working channel of the fl exible endoscope (Fig. 80). We recommend preparing 2 mL of lidocaine 2% with 3 mL of air in a 5-mL syringe. The air in the syringe will push all of the lidocaine solution through the working channel. Two minutes are allowed for the anesthetic to act, then the tip of the endo-scope is advanced through the glottis and into the trachea (next landmark). The tracheal lumen is easily identifi ed and distinguished from the esophagus by the presence of tracheal rings (Table 11, �). Next, a second dose of lidocaine 2%(2 mL, same as for the glottis) is injected through the working channel. Then the tip of the endoscope is pulled back past the glottic plane, and another 2 minutes are allowed for the anesthetic to numb the tracheal mucosa. Now the endoscope is readvanced through the glottis into the trachea and the fi nal landmark, the tracheal bifurcation, is identifi ed (Table 11, �). The endotracheal tube is then carefully advanced through the nostril, which should be well lubricated. A constant endoscopic view of the bifurcation should be maintained during advancement of the tube. It may be diffi cult to pass the tube through the glottis. Occasionally the tip of the tube becomes snagged at the level of the arytenoid cartilage. If this occurs it is often helpful to retract the tube slightly, rotate it 90° clockwise, and readvance it over the endoscope126, 127.

With adequate analgesia and sedation, it is usually possible to pass the tube through the nose and into the trachea without diffi culty and then proceed with the induction of general anesthesia.

In the fi nal step, the distance from the carina to the tip of the endotracheal tube is measured for an accurate assessment of tube position. Final positioning is done by advancing the endoscope tip to the carina and using two fi ngers to mark the insertion depth on the instrument shaft (Fig. 81, �). The instrument is then retracted until the tip of the tube appears in the endoscopic fi eld (Fig. 81, �). The distance from the carina to the tube tip should be 3–5 cm.

Flexible Orotracheal Endoscopic Intubation Endoscopic intubation by the oral route is similar to naso-tracheal intubation. Initial topical anesthesia of the mucosa can be done with nose drops and by numbing the pharynx with a 4% lidocaine spray (see Fig. 77).

Orotracheal intubation is technically more diffi cult because the tip of the intubation endoscope must negotiate a 90° angle in the pharynx on its way to the glottis, and the insertion is not guided by a natural anatomic channel as in the nasal approach. A bite block must be used to protect the instrument in case the patient bites down during the intubation (Fig. 82). Also, it is often diffi cult to visualize the epiglottis in the transoral approach.

Lidocaine 2% is applied to the glottis for topical anesthesia of the vocal cords.

80

The distance from the carina to the tip of the endotracheal tube is measured for the accurate assessment of tube position.

81

� �

A bite block must be used during orotracheal endoscopic intubation.82

Page 40: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine40

It is helpful to have the patient protrude the tongue or apply manual traction to the tongue in order to lift the tongue base from the posterior pharyngeal wall and expose the pharyngeal space. Another option is to place a guide tube to help direct the endoscope through the mouth (Fig. 83).

Flexible Endoscopic Intubation in the Anesthetized Patient Endoscopic intubation of an anesthetized patient requires the presence and help of a second physician experienced in the technique to monitor the patient, render assistance, and ventilate the patient if necessary.

Both nasotracheal and orotracheal endoscopic intubation can be performed in the anesthetized patient. Although topical anesthesia of the mucosa is not strictly necessary in the transnasal approach, it is still a good idea to administer nose drops with a vasoconstrictor in order to prevent bleeding.

Because general anesthesia relaxes muscle tone in the upper airways, the epiglottis often cannot be visualized through the collapsed pharyngeal space. Endoscopic intubation can be performed through an endoscopic face mask or through a ventilation mask fi tted with a Mainz universal adapter (Fig. 84) to maintain ventilation and oxygenation during the procedure. Often it is helpful to have an assistant perform an Eschmach maneuver to lift the tongue base away from the posterior pharyngeal wall so that anatomic landmarks can be identifi ed.

Pharyngeal adjuncts such as the Optosafe® tube (Fig. 83) can help to keep the pharyngeal space open while guiding the orotracheal intubation.

Flexible Endoscopic Intubation of an Unanticipated Diffi cult Airway In many airway algorithms, fl exible fi beroptic or endoscopic intubation is presented as an airway management option after failed laryngoscopy4, 76. An experienced user can perform orotracheal intubation more rapidly then nasotracheal intubation125.

It is important to remember that oxygenation generally takes precedence over endotracheal intubation. Thus, fl exible endoscopic intubation after failed laryngoscopy should be performed through a ventilation mask fi tted with a Mainz universal adapter (Fig. 84) or through an endoscopy face mask to secure ventilation and oxygenation.

Alternatively, the endoscope can be inserted through a guide tube bonded to a bite block (Optosafe®) during fl exible orotracheal endoscopic intubation.

83

Ventilation and oxygenation can be maintained with a face mask, shown here with a Mainz universal adapter, during endoscopic intubation.

84

Page 41: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 41

Flexible Endoscopic Intubation Through the Laryngeal Mask When unexpected diffi culties arise during airway manage-ment, it is often helpful to place a laryngeal mask or ILMA to secure oxygenation and ventilation (see Supraglottic Airway Devices). With the aid of a Mainz adapter, a tube can be placed endoscopically in the trachea while ventilation is continued. This endoscopic placement of the tube has a higher success rate than a blind technique128–130. The set for the LMA Fastrach device includes a spiral-wound tube that is excellent for endoscopic placement. The connector on the spiral tube can be easily removed after successful intubation to facilitate removal of the laryngeal mask (Fig. 85).

During insertion of the fl exible endoscope, the epiglottic elevating bar of the ILMA may hamper advancement of the endoscope tip into the trachea. This can be resolved by passing the endoscope to one side of the obstacle, then advancing it into the trachea. Another option is to pass an endotracheal tube over the endoscope as far as the epiglottic bar, then elevate the bar with the tube so that it no longer blocks the endoscope.

An intubation endoscope can also be passed into the trachea through a classic laryngeal mask128, although problems may result from the relatively long, narrow shaft and the tight airway connector of most laryngeal masks. Given these restrictions, often only a relatively small endotracheal tube can be passed through a classic laryngeal mask. Often the laryngeal mask cannot be safely removed when the proximal end of the endotracheal tube is just above the connector and the distal end of the tube is just below the glottis. This problem can be solved by fi rst passing an intubation rod(e.g., Aintree® catheter) into the trachea endoscopically (see Fig. 55)74. Once inside the trachea, the long catheter will enable the laryngeal mask to be removed without diffi culty. An endotracheal tube can then be introduced over the catheter and its placement confi rmed by fl exible endoscopy.

Endoscopic placement of an endotracheal tube through anintubating laryngeal mask.

85

A large monitor enables all participants to view the progress of the procedure.

86

Page 42: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine42

Flexible Endoscopically Assisted Percutaneous Dilatational Tracheotomy The number of percutaneous dilatational tracheotomies (PDTs) has increased markedly in recent years131. The visual monitoring of PDT using fi beroptics or a fl exible intubation endoscope can prevent life-threatening complications during the procedure.

A video monitor provides optimum guidance for a PDT. It not only guides the procedure itself but also permits the whole team to follow the procedure and give assistance where needed (Fig. 86). The endoscope is passed into the endotracheal tube through a Mainz adapter, for example. The trachea is then inspected and any secretions are suctioned as required. The tracheal cartilage rings should be clearly visible (Fig. 87).

The carina is visualized by bronchoscopy, and the tip of the endoscope is positioned level with the tip of the endotracheal tube, which should project approximately 0.5 cm past the endoscope tip. The edge of the tube should be visible but should not restrict the fi eld of view (Fig. 88).

Now the tube is retracted under bronchoscopic vision to a level just above the glottic plane. The tube can also be slowly retracted under video laryngoscopic guidance. This technique is advantageous in that it reduces the risk of accidental extubation because the tube tip and cuff remain below the glottis (Fig. 89).

After key landmarks have been identifi ed on the anterior side of the neck, the proposed puncture site is transilluminated (Fig. 90). Ideally the puncture site is located between the second and fourth tracheal cartilages. Large blood vessels in the anterior neck can also be located by transillumination.

To prevent bleeding from small cutaneous vessels, a local anesthetic with a vasoconstrictor (e.g., prilocaine 1% plus epinephrine) is injected in the area of the proposed puncture site, which has been marked on the skin.

Next the introducer needle is passed into the trachea under endoscopic control (Fig. 91). The operator can check the

Bronchoscopic view of the trachea. The edge of the endotracheal tube projects approximately 0.5 cm past the endoscope and should not restrict the fi eld of view.

88

The tube is slowly withdrawn to a level just past the glottic plane under video laryngoscopic guidance.

89 External anatomic landmarks are identifi ed, and the proposed puncture site is transilluminated.

90

Flexible endoscopic view of the tracheal lumen.87

Page 43: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 43

position of the puncture site by viewing the monitor. For this step the endoscope should be retracted into the endotracheal tube to avoid accidental puncture of the endoscope shaft. Ideally the trachea is punctured in the midline between the 10 and 2 o’clock positions (Fig. 92). If strong resistance is felt as the needle enters the trachea, the puncture site should be checked as this usually means that the needle has struck the endotracheal tube. In the next step, a 1.5- to 2-cm-long skin incision is made at the marked position. The skin tract is then bluntly dissected and predilated with a nasal speculum or Griggs dilating forceps. Next a Seldinger wire is introduced and advanced toward the carina.

Depending on the system, the next step is dilation of the puncture site. The single-dilator technique will be described here as an example. After dilating the tract with a small dilator, a guide catheter is passed into the trachea over the Seldinger wire under endoscopic control (Fig. 93).

This is followed by single-step dilation of the tract with a Blue Rhino® tapered dilator (Fig. 94). This process should be monitored bronchoscopically so that any injuries or excessive compression of the trachea can be promptly recognized and the procedure modifi ed as needed.

After dilation is completed, the tracheostomy tube is introduced into the trachea over the guide catheter under endoscopic vision and the cuff is infl ated (Fig. 95). The fl exible endoscope is now passed into the trachea through the tracheostomy tube to verify correct endotracheal placement of the tube. It is important to identify the carina so that the tip of the tracheostomy tube can be positioned 3–5 cm above the carina under endoscopic control. Attention should also be given to possible intraluminal bleeding sites.

Endoscopically controlled puncture of the trachea with the introducer needle.

91

Correct puncture site in the trachea.

92

A Seldinger wire is introduced through the Tefl on cannula.93

One-step dilation of the tract under endoscopic control.94 The tracheostomy tube is passed into the trachea over the catheter under endoscopic guidance, and the cuff is infl ated.

95

Page 44: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine44

Endoscopic control offers a number of advantages over blind PDT:

A meta-analysis found that the complication rate of PDT without endoscopy was 16.8%, compared with a rate of 8.3% when endoscopic control was used132.

The greatest risks associated with endoscopically controlled PDT are hypoxia and hypercapnia. A fall in oxygen saturation during dilatational tracheotomy has a reported incidence of 3%132. Hypoventilation, hypercapnia, and respiratory acidosis with hemodynamic deterioration have been described as a result of continuous bronchoscopy during PDT with the

� It provides guidance for the endotracheal tube. If accidental extubation occurs, the tube is easily reinserted into the trachea over the endotracheal endoscope.

� Transillumination can reduce the risk of injury to large blood vessels.

� Visual control of the puncture site within the trachea allows for midline placement of the tracheostomy tube and virtually eliminates the possibility of paramedian placement.

� Dilation is performed under visual control. � Correct position of the tracheostomy tube can be confi rmed after placement.

Anatomy of the larynx. Epiglottis �, hyoid bone �, thyrohyoid membrane �, thyroid cartilage �, laryngeal prominence �,cricoid cartilage �, tracheal cartilage , superior thyroid artery �, cricothyroid artery �, median cricothyroid ligament .

96

Ciaglia kit133, 134. In this study a bronchoscope with a 5.8-mm outer diameter was used in an endotracheal tube with an8.0-mm inner diameter.

When fl exible endoscopes are introduced through the endo-tracheal tube, vision may be signifi cantly obscured due to secretions. There is also a risk of inadvertent puncture of the endotracheal tube cuff, which would jeopardize oxygenation and ventilation.

The placement of a laryngeal mask for PDT is a possible alternative to an endotracheal tube. A randomized study found that the use of a laryngeal mask was associated with a 33% incidence of complications (inadequate ventilation, loss of airway) versus 9.9% with an endotracheal tube135. One limitation of this study is that the male and female laryngeal mask sizes were too small. Contrary to these results, another study found that the use of a laryngeal mask for PDT was associated with a lower incidence of hypercapnia (38.5%) than the use of an endotracheal tube (56.7%)136. In summary, we may conclude that the use of a LMA can signifi cantly improve ventilation and can positively affect the visualization of anatomic structures in the trachea. On the other hand, the user of the LMA must be thoroughly familiar and profi cient with the device in routine clinical use. Data available at present appear insuffi cient to justify a general recommendation or rejection of this technique64.

Invasive Airway Access in Patientswith Failed Oxygenation or Patientswith Failed Oxygenation and Ventilation

Invasive airway access is an emergency procedure and a last-resort option for rescuing a patient from severe hypoxia and death137. It generally consists of a cricothyrotomy and is performed whenever oxygenation and ventilation cannot be established by other available means such as mask ventilation, supraglottic airway placement, or video laryngos-copy (“cannot intubate-cannot ventilate”).

The classic procedure in adults is a surgical cricothyrotomy. Since complications are more frequent with an emergency tracheotomy, a cricothyrotomy is always preferred in emergencies138. Often the key anatomic landmarks for a cricothyrotomy can be reliably identifi ed.

The cricothyroid membrane is the most superfi cial part ofthe airway and is located between the laryngeal prominence and cricoid cartilage (Fig. 96). Typically the membrane is 2.2–3.3 cm wide and 0.9–1 cm high. The principal vessel at this level is the superior thyroid artery, which often runs at the lateral edge of the membrane.

Page 45: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 45

The patient is positioned with the head extended and a cushion beneath the shoulders to expose the neck and its landmarks.

97

A cricothyrotomy may be necessary in the following typical situations:

A cricothyrotomy can be performed by one of two principal methods: surgical dissection or needle techniques. Regard-less of the method used, extension of the neck will make it easier to perform the cricothyrotomy. It may also be helpful to place a pad beneath the shoulders (e.g., a bed pillow) to support and maintain the extended head position during the procedure (Fig. 97).

An emergency cricothyrotomy should be converted within hours to a surgical tracheotomy, or an orotracheal or naso-tracheal airway should be established to prevent serious late sequelae such as tracheal stenosis137.

Surgical Airway The operator palpates the larynx and immobilizes it with one hand after locating the thyroid and cricoid cartilages139. A longitudinal skin incision is made in the midline, starting over the middle of the thyroid cartilage and ending over the cricoid cartilage (Fig. 98). The larynx and cricothyroid ligament in obese patients can be felt with the scalpel by noting a loss of tissue resistance.

Next the subcutaneous fatty tissue is bluntly spread open with a dissecting scissors or nasal speculum (Fig. 99). A transverse incision is made in the cricothyroid membrane, and that incision is spread open with a nasal or Killian speculum. Next an endotracheal tube with stylet (inside tube diameter = 5.0–6.0 mm) is passed into the trachea. This is easiest when the stylet protrudes slightly past the end of the tube139. The nasal speculum is slowly withdrawn during tube insertion to make more room for advancing the tube.

Following successful insertion into the trachea, the cuff of the tube is infl ated, the stylet is removed, and correct tube place-ment is verifi ed by end-tidal CO2 detection and auscultation.

Potential complications include bleeding and injury to laryngeal structures. Failed attempts at tube placement most commonly result from inadequate surgical access.

� Massive swelling of the hypopharynx or oropharynx(e.g., hereditary angioedema following the use of ACE inhibitors.

� Very severe allergic reactions involving the supraglottic airways.

� Very severe burns or caustic injuries of the face and airways.

� Large tumors or infl ammatory masses in the upper airways.

The longitudinal skin incision starts over the middle of the thyroid cartilage and ends over the cricoid cartilage.

98

The subcutaneous fat is bluntly spread open with a nasal speculum, and a transverse incision is made in the cricothyroid membrane.

99

Page 46: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine46

Melker Universal Emergency Cricothyrotomy Catheter Set (Cook Medical).

100 Portex® Crico Kit (Smiths Medical).101

Needle Cricothyrotomy Various systems are available for performing a needle crico-thyrotomy. They are based either on the Seldinger technique (e.g., Melker Universal Emergency Cricothyrotomy Catheter Set, Cook Medical, Fig. 100) or a one-step dilatation principle (e.g., Portex® Crico Kit, Smiths Medical, Fig. 101; QuickTrach® set, VBM Medical, Fig. 102) 137, 139.

In the Seldinger technique (Melker®), a longitudinal skin incision is made with a scalpel over the cricothyroid membrane, analogous to the surgical airway approach. The skin incision should be approximately 1.5–2 cm long. Next a catheter-over-needle unit with a syringe attached is passed into the trachea while continuous aspiration is applied with the syringe. Ideally the syringe should contain some sterile saline solution: air bubbles rising in the syringe will denote passage into the trachea. After the assembly has been placed, the needle and syringe are removed, leaving the catheter in place. Now a guidewire is advanced down the catheter toward the tracheal bifurcation. The Tefl on catheter is removed, and a tracheal tube loaded onto a dilator is passed over the Seldinger wire into the trachea. The Seldinger wire and dilator are withdrawn, and the cuff of the tracheal tube is infl ated. This is followed by ventilation with verifi cation of placement by end-tidal CO2 detection and auscultation.

For one-step dilatation with the Portex Crico Kit (PCK®), the skin is incised and the cricothyroid membrane is punctured with an integral needle/dilator/tracheal tube assembly based on the principle of the Veress needle. As the needle is inserted, the tissue resistance pushes a guide sleeve away from the needle, allowing the sharp steel needle to penetrate the tissue. Entry into the trachea is confi rmed by a red indicator ring in the needle hub. The device is advanced until loss of needle resistance occurs and the red indicator ring disappears. The set is now angled approximately 35° caudally and advanced toward the bifurcation. When it reaches the posterior tracheal wall, the increased resistance causes the red indicator ring to reappear. The puncture needle and dilator are now removed, and the tube is advanced into the trachea. The cuff is infl ated, ventilation is initiated, and correct placement is verifi ed.

The QuickTrach® set embodies another technique for a one-step dilatational cricothyrotomy (Fig. 102). The cricothyroid membrane is identifi ed by palpation, a small skin incision is made, and the needle with attached syringe is passed into the trachea. A stopper on the puncture needle limits the insertion depth to prevent injury to the posterior tracheal wall and esophagus. After air is aspirated with the attached syringe, the stopper is removed and the tracheal tube is advanced over the puncture needle into the trachea. The cuff is infl ated, ventilation is initiated, and correct tube placement is verifi ed (auscultation, capnometry).

Page 47: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 47

One-step dilatational cricothyrotomy with the QuickTrach® set (VBM Medical).

102 A Ravussin needle is passed through the cricothyroid membrane.103

The open port of the three-way stopcock is intermittently occlud ed with the thumb to direct oxygen fl ow down the tracheal catheter, providing temporary oxygenation and minimal ventilation.

104 Manujet III (VBM Medical) for transtracheal jet ventilation.105

Transtracheal Jet Ventilation (TJV) Another, less invasive method for temporary emergency oxygenation is transtracheal jet ventilation. TJV is considered a temporizing procedure for emergency oxygenation; it can-not provide ventilation4. The cricothyroid membrane can be punctured with a special needle (e.g., Ravussin) or with a standard large-bore i.v. catheter (e.g., 14 G) (Fig. 103). After the membrane is identifi ed, the trachea is punctured while continuous aspiration is placed on an attached syringe containing some sterile saline solution. When air bubbles in the syringe confi rm entry into the trachea, the syringe and needle are withdrawn and the Tefl on catheter is advanced toward the bifurcation. In an emergency, oxygen can be quickly insuffl ated through the catheter with a simple setup: a high-fl ow three-way stopcock with 2.5- to 3-mm apertures connected to the catheter hub and an oxygen source. With an oxygen fl ow rate of 15 L/min, the open port of the stopcock can be intermittently occluded to provide oxygenation and minimal ventilation (Fig. 104)140, 141.

The Manujet III (VBM Medical) is a technically streamlined, manually controllable device for transtracheal jet ventilation (Fig. 105). Ventilation is performed through a supplied Ravussin catheter with extra side openings at the tip to ensure oxygen delivery with the tube in place. The device is connected to a pressurized oxygen source via an ISO adapter. A control knob can set the ventilation pressure to any desired value from 0 to 50 psi, which is indicated on a color-coded pressure gauge. Jet ventilation should always be started at a low ventilation pressure, which is then adjusted to obtain the desired ventilation effect.

When this procedure is used, it must be certain that the expired air can be safely vented through the upper airways to reduce the risk of barotrauma. This limits the use of this technique in patients with large tumors or massive swelling of the upper airways.

Page 48: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine48

Evaluation of Various Invasive Airway Techniques Only a few controlled comparative studies have been done on different techniques of invasive airway management. This is probably due to the fact that most of these procedures are used only in extreme emergency situations. Available studies have been done mostly in animals or cadavers. It is diffi cult, therefore, to evaluate and compare the relative utility of speci-fi c techniques. In a recent study, needle cricothyrotomy and surgical cricothyrotomy were compared with each other in a porcine larynx model142. The highest success rate was achieved by needle cricothyrotomy using the Seldinger technique (100% with the Melker® device), followed by surgical cricothyrotomy and the QuickTrach® set (95% each). The Portex Crico Kit® (PCK®) achieved a success rate of 60%. Insertion was fastest with the QuickTrach® (52 s) and surgical approach (59 s) (Melker® set: 94 s, PCK®: 180 s). Another, smaller study compared surgical cricothyrotomy with the Melker® and PCK® sets in a porcine model143. The Melker® set could be correctly placed in all attempts. The surgical technique (55%) and PCK® (30%) were less successful. The different techniques were the same in time to completion (47–63 s). A study in cadavers compared a Seldinger system with surgical cricothyrotomy and found that ventilation was

established faster with the Seldinger system with an equally high success rate (88% versus 84%)144. The surgical approach was associated with more frequent injuries, however.

As for transtracheal jet ventilation, the Manujet system (VBM Medical) was tested in a simulated airway without a proximal constriction and delivered a minute volume (MV) of 3.4 L/minusing a cannula size of 14 G145. Adequate ventilation was not achieved via a three-way stopcock or with a ventilation bag attached to the cannula. In the presence of a proximal constriction above the puncture site, an MV of 12.5 L/min was achieved with the Manujet and 5.3 L/min with the three-way stopcock. This was another scenario in which a ventilation bag was unable to supply adequate ventilation.

The following three-step process is recommended for learning an invasive airway management technique:

1. Identify a preferred method of invasive airway management

2. Practice the method yearly on an airway simulator. Five repetitions are recommended146, 147.

3. If possible, practice the preferred method on cadavers(with consent!).

Preparations

� Confer with the ICU team. (Plan who does what and how.).

� Two physicians should be present(one should be experienced in endotracheal intubation).

� Careful volume replacement in patients without left-sided heart failure (e.g., 500 mL complete electrolyte solution,250 mL colloidal solution).

� Preoxygenate with 100% O2 for 3–4 min. With existing oxygen defi cit: NPPV with pressure support of 5–15 cm H2O, CPAP 5 cm H2O (target: tidal volume of 6–8 mL/kg).

� Prepare emergency medications(e.g., catecholamines, atropine).

Emergency Algorithm forAirway Management in the ICU

The level of anesthesiologic care available in an operating room is not easily transferred to a critical care setting. A great many international algorithms and guidelines have been developed, but not all of them do refl ect the most recent developments in airway management. Moreover, they often fail to address the specifi c requirements of critical care medicine 4, 76.

The goal of algorithms is to guide and support practitioners in specifi c clinical situations. A statistical analysis found that implementation of the ASA Airway Guidelines was followed by a decline in serious malpractice claims relating to diffi cult airway management148.

Table 12 lists possible preparations and techniques of anesthesia induction in critically ill patients based on current recommendations23. The goal of these practice points is to reduce serious complications such as severe hypoxia and cardiovascular instability.

� Anesthesia induction (rapid sequence induction)

� Propofol (1–2 mg/kg) with an opioid(e.g., sufentanil 0.2–0.4 μg/kg) – or – ketanest 1–2 mg/kg. Ketanest is preferred in hemodynamically unstable patients.

� Neuromuscular blockade: succinylcholine 1–1.5 mg/kg(caution: side effects) – or – rocuronium 0.9–1.2 mg/kg. Rocuronium is preferred if sugammadex is available.

After endotracheal intubation

� Verifi cation of tube placement: capnometry/capnography, bilateral auscultation of the lungs.

� Catecholamines if mean arterial pressure is < 65 mm Hg; e.g., norepinephrine titrated to response.

� Start sedation (e.g., propofol, sufentanil)..

� Start lung-protective ventilation: tidal volume 6 mL per kg ideal body weight.

Table 12 Preparations for intubation and anesthesia induction in critical care medicine (modifi ed from Jaber et al. 201023).

Page 49: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 49

An emergency algorithm for airway management in the ICU is also helpful for taking appropriate actions in an emergency situation (Fig. 106). The algorithm shown here is based on existing guidelines and also takes into account new airway management devices (video laryngoscopes) and new pharmacologic agents such as sugammadex for the prompt reversal of rocuronium. The algorithm is intended for use only in patients with an unanticipated diffi cult airway. If signs of

a diffi cult airway are noted before anesthesia induction (see Predictors), the procedure of choice is fl exible endoscopic intubation in the awake, spontaneously breathing patient. Flexible endoscopic intubation can even be performed during noninvasive ventilation with a CPAP mask by using the Mainz universal adapter (see Flexible Endoscopic Intubation in the Awake Patient, p. 35).

In-hospital algorithm for the management of an unanticipated diffi cult airway. Mask ventilation is the starting point because it generally represents the fi rst backup option. The selection of a particular device is based on availability and experience. SP = specialist.

106

Noppens-Piepho Algorithm for Emergency Airway Management

YES

YES

YES

NO

NO

NO

NO

NO NO

NO

NO

NO NO

EMERGENCY: Call for help.Consider neuromuscular blockade;

SP: one intubation attempt(video laryngoscope)

Adequate mask ventilationpossible?

Maximum of 3 intubation attempts (by SP); if possible:

video laryngoscope; call for help

Successful?Successful?

Successful?

Successful? Successful?

Successful?

Adequate mask ventilationpossible?

Return to spontaneous breathingis possible – wake the patient?

Consider antagonists(e.g., sugammadex, naloxone)

Video laryngoscope /alternative blades Supraglottic airway device Flexible or rigid

intubation endoscope

ONE alternative

Videolaryngoscope /

alternative bladesFlexible or

rigid endoscopeSupraglottic

device

Return to spontaneous breathingis possible – wake the patient?

Consider antagonists(e.g., sugammadex, naloxone)

Adequate mask ventilationpossible?

Surgical or percutaneous cricothyrotomy

Page 50: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine50

Mainz Emergency Algorithm for an Unanticipated Diffi cult Airway

Adequate Mask Ventilation is Possible

The Mainz Emergency Algorithm starts with mask ventilation because bag-and-mask ventilation is always the fi rst fallback option when problems arise during endotracheal intubation. Even with rapid sequence induction, mask ventilation should always be used for oxygenation if initial endotracheal intubation fails, despite the increased aspiration risk.

If adequate mask ventilation is possible (left side of the algorithm), there is not an immediate threat of hypoxia. There is suffi cient time to improve the intubation conditions (e.g., position the head) and, if not already done, place a video laryngoscope for endotracheal intubation. If multiple intubation attempts have failed, it is time to call in a physician experienced in endotracheal intubation. It is important to limit the number of intubation attempts (no more than three) because the risk of severe, life-threatening complications increases with the number of intubation attempts45. If laryngoscopic intubation is not successful, it should be asked whether adequate mask ventilation is still possible. If the answer is yes, alternative intubation devices should be tried (Fig. 106). The instruments and devices of fi rst choice are always those with which personnel have had the most clinical experience and are available on the airway cart of the ICU. At this point in the algorithm it must be decided whether endotracheal intubation with an intubation endoscope or a video laryngoscope with an alternative blade is a suitable option. If intubation cannot be achieved with these methods, a supraglottic airway device should be inserted. Afterward an endotracheal tube can be placed through the laryngeal mask with a fl exible intubation endoscope, for example (see Flexible Endoscopic Intubation Through the Laryngeal Mask, p. 41). If an airway still cannot be secured at this time, it

should be decided whether it is feasible to return the patient to spontaneous breathing and discontinue general anesthe-sia. Endoscopic intubation, for example, can be reattempted at a later time in the awake, spontaneously breathing patient.

If you reach a point at which oxygenation and ventilation are no longer possible, go to the right side of the algorithm (Fig. 106).

Adequate Mask Ventilation is Not Possible

If the patient cannot be adequately ventilated and oxygenated with a face mask at any time during airway management, a life-threatening emergency exists. Help from an experienced airway manager should be summoned without delay. If endotracheal intubation and mask ventilation are both unsuccessful, a “cannot intubate – cannot ventilate” situa-tion exists. It should be determined whether a return to spontaneous breathing is an option for oxygenation (see Neuromuscular Blockade, p. 16). If the answer is no, only one more intubation attempt should be made to achieve oxygenation and ventilation at this time (Fig. 106). Often the patient is already severely hypoxic at this stage (Fig. 107), so you should turn to the device that is most familiar and offers the best chance of achieving oxygenation. Given the acute life-threatening situation, the placement of an endotracheal tube is no longer a main priority. The only goal at this point is to oxygenate the patient with a supraglottic or alternative device (Fig. 106). If this is successful, the next step is to establish a defi nitive airway (e.g., a tracheostomy) with expert help. If oxygenation cannot be accomplished with a supraglottic or alternative device, the patient is at an acute risk of death without further action. This situation is marked clinically by severe hypoxia (Fig. 108) and often by initial signs of cardiovascular decompensation. The only remaining option is invasive airway management by cricothyrotomy (see Invasive Airway Access in Patients with Failed Oxygenation and Ventilation, p. 44).

Vital signs in a patient with hypoxia.107 Vital signs in a patient with very severe hypoxia.108

Page 51: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 51

References1. ESTEBAN A, ANZUETO A, ALIA I, GORDO F, APEZTEGUIA C, PALIZAS F,

CIDE D, GOLDWASER R, SOTO L, BUGEDO G, RODRIGO C, PIMENTEL J, RAIMONDI G, TOBIN MJ. How is mechanical ventilation employed in the intensive care unit? An international utilization review. American journal of respiratory and critical care medicine. 2000 May;161(5):1450–8.

2. GARPESTAD E, BRENNAN J, HILL NS. Noninvasive ventilation for critical care. Chest. 2007 Aug;132(2):711–20.

3. TOBIN MJ. Advances in mechanical ventilation. The New England journal of medicine. 2001 Jun 28;344(26):1986–96.

4. (DGAI). Deutsche Gesellschaft für Anästhesie und Intensivmedizin. Leitlinie Airway Management. Anaesth Intensivmed. 2001;45:302–6.

5. GRIESDALE DE, BOSMA TL, KURTH T, ISAC G, CHITTOCK DR. Compli-cations of endotracheal intubation in the critically ill. Intensive care medicine. 2008 Oct;34(10):1835–42.

6. JABER S, AMRAOUI J, LEFRANT JY, ARICH C, COHENDY R, LANDREAU L, CALVET Y, CAPDEVILA X, MAHAMAT A, ELEDJAM JJ. Clinical practice and risk factors for immediate complications of endotracheal intubation in the intensive care unit: a prospective, multiple-center study. Critical care medicine. 2006 Sep;34(9):2355–61.

7. NOPPENS RR, WERNER C, PIEPHO T. [Indirect laryngoscopy: Alternatives to securing the airway]. Der Anaesthesist. 2010 Feb;59(2):149–61.

8. PHUA GC, WAHIDI MM. ICU procedures of the critically ill. Respirology. 2009 Nov;14(8):1092–7.

9. DELANEY A, BAGSHAW SM, NALOS M. Percutaneous dilatational tracheostomy versus surgical tracheostomy in critically ill patients: a systematic review and meta-analysis. Critical care. 2006;10(2):R55.

10. POLDERMAN KH, SPIJKSTRA JJ, DE BREE R, CHRISTIAANS HM, GELISSEN HP, WESTER JP, GIRBES AR. Percutaneous dilatational tra-cheostomy in the ICU: optimal organization, low complication rates, and description of a new complication. Chest. 2003 May;123(5):1595–602.

11. NOPPENS RR, FISCHER S, DAVID M, WERNER C, PIEPHO T. Incidence of diffi cult airway in critical care medicine: a prospective evaluation of tracheal intubation in 106 adults. Critical care medicine. 2009;H. Supp. 37:A189.

12. MARTIN LD, MHYRE JM, SHANKS AM, TREMPER KK, KHETERPAL S. 3,423 emergency tracheal intubations at a university hospital: airway outcomes and complications. Anesthesiology. 2011 Jan;114(1):42–8.

13. DARGIN S, SHUM R, GUYETTE E. A prospective observational study of inhospital airway management performed by intensivists. Critical care medicine. 2009;37:A349.

14. HAGBERG CA, GEORGI R, KRIER C. Complications of managing the air-way. In: Hagberg CA, editor. Benumof’s Airway Management. St. Louis: Mosby Inc.; 2007. p. 1181–216.

15. THIERBACH A, PIEPHO T, WOLCKE B, KUSTER S, DICK W. Präklinische Sicherung der Atemwege. Erfolgsraten und Komplikationen [Prehos-pital emergency airway management procedures. Success rates and complications]. Der Anaesthesist. 2004 Jun;53(6):543–50.

16. TIMMERMANN A, EICH C, RUSSO SG, NATGE U, BRAUER A, ROSEN-BLATT WH, BRAUN U. Prehospital airway management: a prospective evaluation of anaesthesia trained emergency physicians. Resuscitation. 2006 Aug;70(2):179–85.

17. MORT TC. The incidence and risk factors for cardiac arrest during emergency tracheal intubation: a justifi cation for incorporating the ASA Guidelines in the remote location. Journal of clinical anesthesia. 2004 Nov;16(7):508–16.

18. PRONOVOST PJ, ANGUS DC, DORMAN T, ROBINSON KA, DREMSIZOV TT, YOUNG TL. Physician staffi ng patterns and clinical outcomes in critically ill patients: a systematic review. JAMA : the journal of the American Medical Association. 2002 Nov 6;288(17):2151–62.

19. DORMAN T, ANGOOD PB, ANGUS DC, CLEMMER TP, COHEN NH, DURBIN CG, JR., FALK JL, HELFAER MA, HAUPT MT, HORST HM, IVY ME, OGNIBENE FP, SLADEN RN, GRENVIK AN, NAPOLITANO LM. American College of Critical Care Medicine. Guidelines for critical care medicine training and continuing medical education. Critical care medicine. 2004 Jan;32(1):263–72.

20. NAYYAR P, LISBON A. Non-operating room emergency airway manage-ment and endotracheal intubation practices: a survey of anesthesiology program directors. Anesthesia and analgesia. 1997 Jul;85(1):62–8.

21. KONRAD C, SCHÜPFER G, WIETLISBACH M, GERBER H. Learning manual skills in anesthesiology: Is there a recommended number of cases for anesthetic procedures? Anesthesia and analgesia. 1998 Mar;86(3):635–9.

22. MULCASTER JT, MILLS J, HUNG OR, MACQUARRIE K, LAW JA, PYTKA S, IMRIE D, FIELD C. Laryngoscopic intubation: learning and performance. Anesthesiology. 2003 Jan;98(1):23–7.

23. JABER S, JUNG B, CORNE P, SEBBANE M, MULLER L, CHANQUES G, VERZILLI D, JONQUET O, ELEDJAM JJ, LEFRANT JY. An intervention to decrease complications related to endotracheal intubation in the intensive care unit: a prospective, multiple-center study. Intensive care medicine. 2010 Feb;36(2):248–55.

24. JABRE P, COMBES X, LAPOSTOLLE F, DHAOUADI M, RICARD-HIBON A, VIVIEN B, BERTRAND L, BELTRAMINI A, GAMAND P, ALBIZZATI S, PER-DRIZET D, LEBAIL G, CHOLLET-XEMARD C, MAXIME V, BRUN-BUISSON C, LEFRANT JY, BOLLAERT PE, MEGARBANE B, RICARD JD, ANGUEL N, VICAUT E, ADNET F, GROUP KCS. KETASED Collaborative Study Group. Etomidate versus ketamine for rapid sequence intubation in acutely ill patients: a multicentre randomised controlled trial. Lancet. 2009 Jul 25;374(9686):293–300.

25. OLIWA N, MORT TC. National ICU diffi cult airway survey: preliminary results. Anesthesiology. 2003;99:A403.

26. GEORGIOU AP, GOULDSON S, AMPHLETT AM. The use of capnography and the availability of airway equipment on Intensive Care Units in the UK and the Republic of Ireland. Anaesthesia. 2010 May;65(5):462–7.

27. OVASSAPIAN A, YELICH SJ, DYKES MH, BRUNNER EE. Fiberoptic naso-tracheal intubation – incidence and causes of failure. Anesthesia and analgesia. 1983 Jul;62(7):692–5.

28. MORT TC. Preoxygenation in critically ill patients requiring emergency tracheal intubation. Critical care medicine. 2005 Nov;33(11):2672–5.

29. MORT TC, WABERSKI BH, CLIVE J. Extending the preoxygenation period from 4 to 8 mins in critically ill patients undergoing emergency intuba-tion. Critical care medicine. 2009 Jan;37(1):68–71.

30. DELAY JM, SEBBANE M, JUNG B, NOCCA D, VERZILLI D, POUZERATTE Y, KAMEL ME, FABRE JM, ELEDJAM JJ, JABER S. The effectiveness of noninvasive positive pressure ventilation to enhance preoxygenation in morbidly obese patients: a randomized controlled study. Anesthesia and analgesia. 2008 Nov;107(5):1707–13.

31. BAILLARD C, FOSSE JP, SEBBANE M, CHANQUES G, VINCENT F, COUROUBLE P, COHEN Y, ELEDJAM JJ, ADNET F, JABER S. Noninvasive ventilation improves preoxygenation before intubation of hypoxic patients. American journal of respiratory and critical care medicine. 2006 Jul 15;174(2):171–7.

Page 52: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine52

32. BAIRD CR, HAY AW, MCKEOWN DW, RAY DC. Rapid sequence induction in the emergency department: induction drug and outcome of patients admitted to the intensive care unit. Emergency medicine journal : EMJ. 2009 Aug;26(8):576–9.

33. CUTHBERTSON BH, SPRUNG CL, ANNANE D, CHEVRET S, GARFIELD M, GOODMAN S, LATERRE PF, VINCENT JL, FREIVOGEL K, REINHART K, SINGER M, PAYEN D, WEISS YG. The effects of etomidate on adrenal responsiveness and mortality in patients with septic shock. Intensive care medicine. 2009 Nov;35(11):1868–76.

34. HOHL CM, KELLY-SMITH CH, YEUNG TC, SWEET DD, DOYLE-WATERS MM, SCHULZER M. The effect of a bolus dose of etomidate on cortisol levels, mortality, and health services utilization: a systematic review. Annals of emergency medicine. 2010 Aug;56(2):105–13 e5.

35. CHAMBERS D, PAULDEN M, PATON F, HEIRS M, DUFFY S, HUNTER JM, SCULPHER M, WOOLACOTT N. Sugammadex for reversal of neuromuscular block after rapid sequence intubation: a systematic review and economic assessment. British journal of anaesthesia. 2010 Nov;105(5):568–75.

36. PERRY JJ, LEE JS, SILLBERG VA, WELLS GA. Rocuronium versus succi-nylcholine for rapid sequence induction intubation. Cochrane database of systematic reviews. 2008(2):CD002788.

37. NOLAN JP, SOAR J, ZIDEMAN DA, BIARENT D, BOSSAERT LL, DEAKIN C, KOSTER RW, WYLLIE J, BÖTTIGER B, GROUP ERCGW. European Resus-citation Council Guidelines for Resuscitation 2010 Section 1. Executive summary. Resuscitation. 2010 Oct;81(10):1219–76.

38. SCHWARTZ DE, MATTHAY MA, COHEN NH. Death and other compli-cations of emergency airway management in critically ill adults. A prospective investigation of 297 tracheal intubations. Anesthesiology. 1995 Feb;82(2):367–76.

39. TIRET L, DESMONTS JM, HATTON F, VOURC‘H G. Complications associated with anaesthesia – a prospective survey in France. Canadian Anaesthetists‘ Society journal. 1986 May;33(3 Pt 1):336–44.

40. ORNATO JP, GARNETT AR, GLAUSER FL. Relationship between cardiac output and the end-tidal carbon dioxide tension. Annals of emergency medicine. 1990 Oct;19(10):1104–6.

41. KASPER CL, DEEM S. The self-infl ating bulb to detect esophageal in-tubation during emergency airway management. Anesthesiology. 1998 Apr;88(4):898–902.

42. BARAKA A, KHOURY PJ, SIDDIK SS, SALEM MR, JOSEPH NJ. Effi cacy of the self-infl ating bulb in differentiating esophageal from tracheal intubation in the parturient undergoing cesarean section. Anesthesia and analgesia. 1997 Mar;84(3):533–7.

43. LANG DJ, WAFAI Y, SALEM MR, CZINN EA, HALIM AA, BARAKA A. Effi cacy of the self-infl ating bulb in confi rming tracheal intubation in the morbidly obese. Anesthesiology. 1996 Aug;85(2):246–53.

44. BOYLAN JF, KAVANAGH BP. Emergency airway management: compe-tence versus expertise? Anesthesiology. 2008 Dec;109(6):945–7.

45. MORT TC. Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts. Anesthesia and analgesia. 2004 Aug;99(2):607–13, table of contents.

46. KAPLAN MB, HAGBERG CA, WARD DS, BRAMBRINK A, CHHIBBER AK, HEIDEGGER T, LOZADA L, OVASSAPIAN A, PARSONS D, RAMSAY J, WILHELM W, ZWISSLER B, GERIG HJ, HOFSTETTER C, KARAN S, KREISLER N, POUSMAN RM, THIERBACH A, WROBEL M, BERCI G. Com-parison of direct and video-assisted views of the larynx during routine intubation. Journal of clinical anesthesia. 2006 Aug;18(5):357–62.

47. CAVUS E, KIECKHAEFER J, DOERGES V, MOELLER T, THEE C, WAGNER K. The C-MAC videolaryngoscope: fi rst experiences with a new device for videolaryngoscopy-guided intubation. Anesthesia and analgesia. 2010 Feb 1;110(2):473–7.

48. PIEPHO T, WEINERT K, HEID FM, WERNER C, NOPPENS RR. Comparison of the McGrath(R) Series 5 and GlideScope(R) Ranger with the Macin-tosh laryngoscope by paramedics. Scandinavian journal of trauma, resuscitation and emergency medicine. 2011;19(1):4.

49. RAI MR, DERING A, VERGHESE C. The Glidescope system: a clinical as-sessment of performance. Anaesthesia. 2005 Jan;60(1):60–4.

50. SAVOLDELLI GL, SCHIFFER E, ABEGG C, BAERISWYL V, CLERGUE F, WAEBER JL. Comparison of the Glidescope, the McGrath, the Airtraq and the Macintosh laryngoscopes in simulated diffi cult airways*. Anaesthesia. 2008 Dec;63(12):1358–64.

51. SAVOLDELLI GL, SCHIFFER E, ABEGG C, BAERISWYL V, CLERGUE F, WAEBER JL. Learning curves of the Glidescope, the McGrath and the Airtraq laryngoscopes: a manikin study. European journal of anaesthe-siology. 2009 Jul;26(7):554–8.

52. MAASSEN R, LEE R, HERMANS B, MARCUS M, VAN ZUNDERT A. A comparison of three videolaryngoscopes: the Macintosh laryngo-scope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients. Anesthesia and analgesia. 2009 Nov;109(5):1560–5.

53. JONES PM, TURKSTRA TP, ARMSTRONG KP, ARMSTRONG PM, CHERRY RA, HOOGSTRA J, HARLE CC. Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope. Canadian journal of anaesthesia = Journal canadien d‘anesthesie. 2007 Jan;54(1):21–7.

54. MCELWAIN J, MALIK MA, HARTE BH, FLYNN NM, LAFFEY JG. Compari-son of the C-MAC videolaryngoscope with the Macintosh, Glidescope, and Airtraq laryngoscopes in easy and diffi cult laryngoscopy scenarios in manikins. Anaesthesia. 2010 May;65(5):483–9.

55. TURKSTRA TP, HARLE CC, ARMSTRONG KP, ARMSTRONG PM, CHERRY RA, HOOGSTRA J, JONES PM. The GlideScope-specifi c rigid stylet and standard malleable stylet are equally effective for GlideScope use. Canadian journal of anaesthesia = Journal canadien d‘anesthesie. 2007 Nov;54(11):891–6.

56. MUALLEM M, BARAKA A. Tracheal intubation using the GlideScope with a combined curved pipe stylet, and endotracheal tube introducer. Ca-nadian journal of anaesthesia = Journal canadien d‘anesthesie. 2007 Jan;54(1):77–8.

57. XUE FS, YANG QY, HE N, XU YC. The modifi ed ventilating tube changer to facilitate tracheal intubation using the GlideScope in patients with a limited mouth opening. British journal of anaesthesia. 2008 Jul;101(1):126–7.

58. HOFSTETTER C, SCHELLER B, FLONDOR M, GERIG HJ, HEIDEGGER T, BRAMBRINK A, THIERBACH A, WILHELM W, WROBEL M, ZWISSLER B. [Videolaryngoscopy versus direct laryngoscopy for elective endo-tracheal intubation]. Der Anaesthesist. 2006 May;55(5):535–40.

59. JUNGBAUER A, SCHUMANN M, BRUNKHORST V, BORGERS A, GROEBEN H. Expected diffi cult tracheal intubation: a prospective com-parison of direct laryngoscopy and video laryngoscopy in 200 patients. British journal of anaesthesia. 2009 Apr;102(4):546–50.

60. BYHAHN C, IBER T, ZACHAROWSKI K, WEBER CF, RUESSELER M, SCHALK R, MEININGER D. Tracheal intubation using the mobile C-MAC video laryngoscope or direct laryngoscopy for patients with a simulated diffi cult airway. Minerva anestesiologica. 2010 Aug;76(8):577–83.

Page 53: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 53

61. PIEPHO T, FORTMUELLER K, HEID FM, SCHMIDTMANN I, WERNER C, NOPPENS RR. Performance of the C-MAC video laryngoscope in patients after a limited glottic view using Macintosh laryngoscopy. Anaesthesia. 2011 Dec;66(12):1101–5.

62. AZIZ MF, HEALY D, KHETERPAL S, FU RF, DILLMAN D, BRAMBRINK AM. Routine clinical practice effectiveness of the Glidescope in diffi cult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions. Anesthesiology. 2011 Jan;114(1):34–41.

63. NOPPENS RR, GEIMER S, EISEL N, DAVID M, PIEPHO T. Endotracheal intubation using the C-MAC® video laryngoscope or the Macintosh laryngoscope: A prospective, comparative study in the ICU. Critical care. 2012 Jun 13;16(3):R103.

64. RUSSO SG, MOERER O, NICKEL EA, GOETZE B, TIMMERMANN A, QUINTEL M. [Extraglottic airway devices in the intensive care unit]. Der Anaesthesist. 2010 Jun;59(6):555–63.

65. HOWES BW, WHARTON NM, GIBBISON B, COOK TM. LMA Supreme insertion by novices in manikins and patients. Anaesthesia. 2010 Apr;65(4):343–7.

66. SCHALK R, SCHELLER B, HABLER OP, MEIER J, MEININGER D, BYHAHN C. Disposable laryngeal tube suction – a randomized comparison of two insertion techniques performed by novice users in anaesthetised patients. Resuscitation. 2008 Mar;76(3):364–8.

67. HOHLRIEDER M, BRIMACOMBE J, VON GOEDECKE A, KELLER C. Guided insertion of the ProSeal laryngeal mask airway is superior to conventional tracheal intubation by fi rst-month anesthesia residents after brief manikin-only training. Anesthesia and analgesia. 2006 Aug;103(2):458–62, table of contents.

68. THIERBACH A, PIEPHO T, KLEINE-WEISCHEDE B, HAAG G, MAYBAUER M, WERNER C. [Comparison between the laryngeal tubus S and endotra-cheal intubation. Simulation of securing the airway in an emergency situation]. Der Anaesthesist. 2006 Feb;55(2):154–9.

69. TANIGAWA K, SHIGEMATSU A. Choice of airway devices for 12,020 cases of nontraumatic cardiac arrest in Japan. Prehospital emergency care : offi cial journal of the National Association of EMS Physicians and the National Association of State EMS Directors. 1998 Apr–Jun;2(2):96–100.

70. NIXON T, BRIMACOMBE J, GOLDRICK P, MCMANUS S. Airway rescue with the ProSeal laryngeal mask airway in the intensive care unit. Anaesthesia and intensive care. 2003 Aug;31(4):475–6.

71. BRIMACOMBE JR, BERRY A. The incidence of aspiration associated with the laryngeal mask airway: a meta-analysis of published literature. Journal of clinical anesthesia. 1995 Jun;7(4):297–305.

72. STONE BJ, CHANTLER PJ, BASKETT PJ. The incidence of regurgita-tion during cardiopulmonary resuscitation: a comparison between the bag valve mask and laryngeal mask airway. Resuscitation. 1998 Jul;38(1):3–6.

73. TIMMERMANN A. [Modern airway management – current concepts for more patient safety]. Anasthesiologie, Intensivmedizin, Notfallmedizin, Schmerztherapie : AINS. 2009 Apr;44(4):246–55; quiz 56.

74. BLAIR EJ, MIHAI R, COOK TM. Tracheal intubation via the Classic and Proseal laryngeal mask airways: a manikin study using the Aintree Intubating Catheter. Anaesthesia. 2007 Apr;62(4):385–7.

75. BRAIN AI, MCGHEE TD, MCATEER EJ, THOMAS A, ABU-SAAD MA, BUSH-MAN JA. The laryngeal mask airway. Development and preliminary trials of a new type of airway. Anaesthesia. 1985 Apr;40(4):356–61.

76. AMERICAN SOCIETY OF ANESTHESIOLOGISTS TASK FORCE ON MAN-AGEMENT OF THE DIFFICULT A. Practice guidelines for management of the diffi cult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Diffi cult Airway. Anesthesiology. 2003 May;98(5):1269–77.

77. HENDERSON JJ, POPAT MT, LATTO IP, PEARCE AC, DIFFICULT AIRWAY S. Diffi cult Airway Society guidelines for management of the unanticipated diffi cult intubation. Anaesthesia. 2004 Jul;59(7):675–94.

78. COOK TM, TRUMPELMANN P, BERINGER R, STEDEFORD J. A randomised comparison of the Portex Softseal laryngeal mask airway with the LMA-Unique during anaesthesia. Anaesthesia. 2005 Dec;60(12):1218–25.

79. FRANCKSEN H, BEIN B, CAVUS E, RENNER J, SCHOLZ J, STEINFATH M, TONNER PH, DOERGES V. Comparison of LMA Unique, Ambu laryngeal mask and Soft Seal laryngeal mask during routine surgical procedures. European journal of anaesthesiology. 2007 Feb;24(2):134–40.

80. SHIN WJ, CHEONG YS, YANG HS, NISHIYAMA T. The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients. European journal of anaesthesiology. 2010 Jul;27(7):598–601.

81. HEUER JF, STILLER M, RATHGEBER J, EICH C, ZUCHNER K, BAUER M, TIMMERMANN A. [Evaluation of the new supraglottic airway devices Ambu AuraOnce and Intersurgical i-gel. Positioning, sealing, patient comfort and airway morbidity]. Der Anaesthesist. 2009 Aug;58(8):813–20.

82. UPPAL V, GANGAIAH S, FLETCHER G, KINSELLA J. Randomized crossover comparison between the i-gel and the LMA-Unique in anaesthetized, paralysed adults. British journal of anaesthesia. 2009 Dec;103(6):882–5.

83. EMMERICH M, DUMMLER R. [Use of the i-gel laryngeal mask for man-agement of a diffi cult airway]. Der Anaesthesist. 2008 Aug;57(8):779–81.

84. ESCHERTZHUBER S, BRIMACOMBE J, HOHLRIEDER M, KELLER C. The laryngeal mask airway Supreme – a single use laryngeal mask airway with an oesophageal vent. A randomised, cross-over study with the laryngeal mask airway ProSeal in paralysed, anaesthetised patients. Anaesthesia. 2009 Jan;64(1):79–83.

85. PEARSON DM, YOUNG PJ. Use of the LMA-Supreme for airway rescue. Anesthesiology. 2008 Aug;109(2):356–7.

86. COOK TM, LEE G, NOLAN JP. The ProSeal laryngeal mask airway: a review of the literature. Canadian journal of anaesthesia = Journal canadien d‘anesthesie. 2005 Aug–Sep;52(7):739–60.

87. CHOYCE A, AVIDAN MS, PATEL C, HARVEY A, TIMBERLAKE C, MC-NEILIS N, GLUCKSMAN E. Comparison of laryngeal mask and intubat-ing laryngeal mask insertion by the naive intubator. British journal of anaesthesia. 2000 Jan;84(1):103–5.

88. TIMMERMANN A, RUSSO SG, CROZIER TA, EICH C, MUNDT B, ALBRECHT B, GRAF BM. Novices ventilate and intubate quicker and safer via intubating laryngeal mask than by conventional bag-mask ventilation and laryngoscopy. Anesthesiology. 2007 Oct;107(4):570–6.

89. FERSON DZ, ROSENBLATT WH, JOHANSEN MJ, OSBORN I, OVAS-SAPIAN A. Use of the intubating LMA-Fastrach in 254 patients with diffi cult-to-manage airways. Anesthesiology. 2001 Nov;95(5):1175–81.

90. BASKETT PJ, PARR MJ, NOLAN JP. The intubating laryngeal mask. Re-sults of a multicentre trial with experience of 500 cases. Anaesthesia. 1998 Dec;53(12):1174–9.

Page 54: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine54

91. GERSTEIN NS, BRAUDE DA, HUNG O, SANDERS JC, MURPHY MF. The Fastrach Intubating Laryngeal Mask Airway: an overview and update. Canadian journal of anaesthesia = Journal canadien d‘anesthesie. 2010 Jun;57(6):588–601.

92. KOMATSU R, NAGATA O, KAMATA K, YAMAGATA K, SESSLER DI, OZAKI M. Comparison of the intubating laryngeal mask airway and laryngeal tube placement during manual in-line stabilisation of the neck. Anaesthesia. 2005 Feb;60(2):113–7.

93. THEE C, SEROCKI G, DOERGES V, ILIES C, WALLENIUS K, BEIN B, STEINFATH M, CAVUS E. Laryngeal tube S II, laryngeal tube S dispos-able, Fastrach laryngeal mask and Fastrach laryngeal mask dispos-able during elective surgery: a randomized controlled comparison be-tween reusable and disposable supraglottic airway devices. European journal of anaesthesiology. 2010 May;27(5):468–72.

94. KELLER C, BRIMACOMBE J, BITTERSOHL J, LIRK P, VON GOEDECKE A. Aspiration and the laryngeal mask airway: three cases and a review of the literature. British journal of anaesthesia. 2004 Oct;93(4):579–82.

95. FRASS M, JOHNSON JC, ATHERTON GL, FRUHWALD FX, TRAINDL O, SCHWAIGHOFER B, LEITHNER C. Esophageal tracheal combitube (ETC) for emergency intubation: anatomical evaluation of ETC place-ment by radiography. Resuscitation. 1989 Oct;18(1):95–102.

96. DÖRGES V, PASCHEN H-R. Management des schwierigen Atemwegs. Berlin Heidelberg New York: Springer-Verlag; 2004.

97. URTUBIA RM, AGUILA CM, CUMSILLE MA. Combitube: a study for proper use. Anesthesia and analgesia. 2000 Apr;90(4):958–62.

98. BEIN B, CARSTENSEN S, GLEIM M, CLAUS L, TONNER PH, STEIN-FATH M, SCHOLZ J, DORGES V. A comparison of the proseal laryn-geal mask airway, the laryngeal tube S and the oesophageal-tracheal combitube during routine surgical procedures. European journal of anaesthesiology. 2005 May;22(5):341–6.

99. AGRO F, FRASS M, BENUMOF JL, KRAFFT P. Current status of the Combitube: a review of the literature. Journal of clinical anesthesia. 2002 Jun;14(4):307–14.

100. YARDY N, HANCOX D, STRANG T. A comparison of two airway aids for emergency use by unskilled personnel. The Combitube and laryngeal mask. Anaesthesia. 1999 Feb;54(2):181–3.

101. JAEHNICHEN G, GOLECKI N, LIPP MD. A case report of dif-fi cult ventilation with the Combitube – valve-like upper airway obstruction confi rmed by fi breoptic visualisation. Resuscitation. 2000 Mar;44(1):71–4.

102. THIERBACH AR, PIEPHO T, MAYBAUER MO. A new device for emer-gency airway management: the EasyTube. Resuscitation. 2004 Mar;60(3):347.

103. LORENZ V, RICH JM, SCHEBESTA K, TASLAKIAN S, MULLNER M, FRASS M, SCHUSTER E, ILLIEVICH UM, KAYE AD, VAIDA S, KRAFFT P. Comparison of the EasyTube and endotracheal tube during gen-eral anesthesia in fasted adult patients. Journal of clinical anesthesia. 2009 Aug;21(5):341–7.

104. CHENAITIA H, SOULLEIHET V, MASSA H, BESSEREAU J, BOURENNE J, MICHELET P, AUFFRAY JP. The Easytube for airway manage-ment in prehospital emergency medicine. Resuscitation. 2010 Nov;81(11):1516–20.

105. CAVUS E, DEITMER W, FRANCKSEN H, SEROCKI G, BEIN B, SCHOLZ J, DOERGES V. Laryngeal tube S II, ProSeal laryngeal mask, and Easy-Tube during elective surgery: a randomized controlled comparison with the endotracheal tube in nontrained professionals. European journal of anaesthesiology. 2009 Sep;26(9):730–5.

106. ASAI T, MURAO K, SHINGU K. Effi cacy of the laryngeal tube dur-ing intermittent positive-pressure ventilation. Anaesthesia. 2000 Nov;55(11):1099–102.

107. ASAI T, SHINGU K. The laryngeal tube. British journal of anaesthesia. 2005 Dec;95(6):729–36.

108. BRIMACOMBE J, KELLER C, BRIMACOMBE L. A comparison of the laryngeal mask airway ProSeal and the laryngeal tube airway in paralyzed anesthetized adult patients undergoing pressure-controlled ventilation. Anesthesia and analgesia. 2002 Sep;95(3):770–6, table of contents.

109. COOK TM, MCKINSTRY C, HARDY R, TWIGG S. Randomized crossover comparison of the ProSeal laryngeal mask airway with the Laryngeal Tube during anaesthesia with controlled ventilation. British journal of anaesthesia. 2003 Nov;91(5):678–83.

110. GENZWUERKER HV, VOLLMER T, ELLINGER K. Fibreoptic tracheal intubation after placement of the laryngeal tube. British journal of anaesthesia. 2002 Nov;89(5):733–8.

111. SCHALK R, BYHAHN C, FAUSEL F, EGNER A, OBERNDORFER D, WALCHER F, LATASCH L. Out-of-hospital airway management by paramedics and emergency physicians using laryngeal tubes. Resus-citation. 2010 Mar;81(3):323–6.

112. WIESE CH, SEMMEL T, MULLER JU, BAHR J, OCKER H, GRAF BM. The use of the laryngeal tube disposable (LT-D) by paramedics during out-of-hospital resuscitation – an observational study concerning ERC guidelines 2005. Resuscitation. 2009 Feb;80(2):194–8.

113. HEUER JF, BARWING J, EICH C, QUINTEL M, CROZIER TA, ROESSLER M. Initial ventilation through laryngeal tube instead of face mask in out-of-hospital cardiopulmonary arrest is effective and safe. European journal of emergency medicine : offi cial journal of the European Society for Emergency Medicine. 2010 Feb;17(1):10–5.

114. COOK TM, MCCORMICK B, ASAI T. Randomized comparison of laryngeal tube with classic laryngeal mask airway for anaesthesia with controlled ventilation. British journal of anaesthesia. 2003 Sep;91(3):373–8.

115. DENGLER V, WILDE P, BYHAHN C, MACK MG, SCHALK R. [Prehospital airway management of laryngeal tubes. Should the laryngeal tube S with gastric drain tube be preferred in emergency medicine?]. Der Anaesthesist. 2011 Feb;60(2):135–8.

116. SCHELLER B, WALCHER F, BYHAHN C, ZACHAROWSKI K, BINGOLD TM, SCHALK R. [Laryngeal tube suction]. Der Anaesthesist. 2010 Mar;59(3):210–2, 4–6.

117. PIEPHO T, WERNER C, NOPPENS RR. Evaluation of the novel, single-use, fl exible aScope for tracheal intubation in the simu-lated diffi cult airway and fi rst clinical experiences. Anaesthesia. 2010 Aug;65(8):820–5.

118. STACKHOUSE RA, MARKS JD, BAINTON CR. Performing fi beroptic endotracheal intubation: clinical aspects. International anesthesiology clinics. 1994 Fall;32(4):57–73.

119. OVASSAPIAN A, TUNCBILEK M, WEITZEL EK, JOSHI CW. Airway management in adult patients with deep neck infections: a case series and review of the literature. Anesthesia and analgesia. 2005 Feb;100(2):585–9.

120. FULLING PD, ROBERTS JT. Fiberoptic intubation. International anes-thesiology clinics. 2000 Summer;38(3):189–217.

121. REED AP. Preparation for intubation of the awake patient. The Mount Sinai journal of medicine, New York. 1995 Jan;62(1):10–20.

Page 55: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 55

122. ANTONELLI M, CONTI G, RICCIONI L, MEDURI GU. Noninvasive positive-pressure ventilation via face mask during bronchoscopy with BAL in high-risk hypoxemic patients. Chest. 1996 Sep;110(3):724–8.

123. MACHATA AM, GONANO C, HOLZER A, ANDEL D, SPISS CK, ZIMPFER M, ILLIEVICH UM. Awake nasotracheal fi beroptic intubation: patient comfort, intubating conditions, and hemodynamic stability during conscious sedation with remifentanil. Anesthesia and analgesia. 2003 Sep;97(3):904–8.

124. PUCHNER W, EGGER P, PUHRINGER F, LOCKINGER A, OBWEGESER J, GOMBOTZ H. Evaluation of remifentanil as single drug for awake fi beroptic intubation. Acta anaesthesiologica Scandinavica. 2002 Apr;46(4):350–4.

125. KÖRNER IP, BRAMBRINK AM. Fiberoptic techniques. Best practice & research Clinical anaesthesiology. 2005 Dec;19(4):611–21.

126. GREER JR, SMITH SP, STRANG T. A comparison of tracheal tube tip designs on the passage of an endotracheal tube during oral fi beroptic intubation. Anesthesiology. 2001 May;94(5):729–31; discussion 5A.

127. JOHNSON DM, FROM AM, SMITH RB, FROM RP, MAKTABI MA. Endo-scopic study of mechanisms of failure of endotracheal tube advance-ment into the trachea during awake fi beroptic orotracheal intubation. Anesthesiology. 2005 May;102(5):910–4.

128. ASAI T. Tracheal intubation through the laryngeal mask airway. Anes-thesiology. 1996 Aug;85(2):439.

129. JOO HS, ROSE DK. The intubating laryngeal mask airway with and without fi beroptic guidance. Anesthesia and analgesia. 1999 Mar;88(3):662–6.

130. KOGA K, ASAI T, LATTO IP, VAUGHAN RS. Effect of the size of a tracheal tube and the effi cacy of the use of the laryngeal mask for fi brescope-aided tracheal intubation. Anaesthesia. 1997 Feb;52(2):131–5.

131. KOITSCHEV A, GRAUMUELLER S, DOMMERICH S, KIOTSCHEV C, SIMON C. [Tracheostomy in intensive care medicine. Is the ENT specialist still needed?]. Hno. 2003 Aug;51(8):616–20.

132. KOST KM. Endoscopic percutaneous dilatational tracheotomy: a prospective evaluation of 500 consecutive cases. The Laryngoscope. 2005 Oct;115(10 Pt 2):1–30.

133. REILLY PM, ANDERSON HL, 3RD, SING RF, SCHWAB CW, BARTLETT RH. Occult hypercarbia. An unrecognized phenomenon during percutane-ous endoscopic tracheostomy. Chest. 1995 Jun;107(6):1760–3.

134. REILLY PM, SING RF, GIBERSON FA, ANDERSON HL, 3RD, ROTON-DO MF, TINKOFF GH, SCHWAB CW. Hypercarbia during tracheostomy: a comparison of percutaneous endoscopic, percutaneous Doppler, and standard surgical tracheostomy. Intensive care medicine. 1997 Aug;23(8):859-64.

135. AMBESH SP, SINHA PK, TRIPATHI M, MATREJA P. Laryngeal mask airway vs endotracheal tube to facilitate bedside percutaneous tra-cheostomy in critically ill patients: a prospective comparative study. Journal of postgraduate medicine. 2002 Jan-Mar;48(1):11-5.

136. DOSEMECI L, YILMAZ M, GURPINAR F, RAMAZANOGLU A. The use of the laryngeal mask airway as an alternative to the endotracheal tube during percutaneous dilatational tracheostomy. Intensive care medicine. 2002 Jan;28(1):63-7.

137. BYHAHN C, MEININGER D. [Invasive airway management]. Anasthesi-ologie, Intensivmedizin, Notfallmedizin, Schmerztherapie : AINS. 2006 Sep;41(9):576-87.

138. BROFELDT BT, PANACEK EA, RICHARDS JR. An easy cricothyrotomy approach: the rapid four-step technique. Academic emergency medi-cine : offi cial journal of the Society for Academic Emergency Medicine. 1996 Nov;3(11):1060-3.

139. MUTZBAUER TS, KEUL W, BERNHARD M, VOLKL A, GRIES A. [Invasive techniques in emergency medicine. IV. Cricothyrotomy in emergency situations]. Der Anaesthesist. 2005 Feb;54(2):145-54.

140. GAL TJ. Airway Management. In: Miller RD, editor. Miller’s Anesthesia. Philadelphia, PA: Elsevier / Churchill Livingstone; 2005. p. 1617-52.

141. SCHWARZKOPF K, HUTER L, PREUSSLER NP, SCHAFER R, SCH-REIBER T. [Preclinical transtracheal emergency ventilation. Animal experimental comparison of two techniques]. Der Anaesthesist. 2007 Nov;56(11):1115-9.

142. MURPHY C, ROONEY SJ, MAHARAJ CH, LAFFEY JG, HARTE BH. Com-parison of three cuffed emergency percutaneous cricothyroidotomy devices to conventional surgical cricothyroidotomy in a porcine model. British journal of anaesthesia. 2011 Jan;106(1):57-64.

143. MARIAPPA V, STACHOWSKI E, BALIK M, CLARK P, NAYYAR V. Crico-thyroidotomy: comparison of three different techniques on a porcine airway. Anaesthesia and intensive care. 2009 Nov;37(6):961-7.

144. SCHAUMANN N, LORENZ V, SCHELLONGOWSKI P, STAUDINGER T, LOCKER GJ, BURGMANN H, PIKULA B, HOFBAUER R, SCHUSTER E, FRASS M. Evaluation of Seldinger technique emergency cricothyroid-otomy versus standard surgical cricothyroidotomy in 200 cadavers. Anesthesiology. 2005 Jan;102(1):7-11.

145. FLINT NJ, RUSSELL WC, THOMPSON JP. Comparison of different methods of ventilation via cannula cricothyroidotomy in a trachea-lung model. British journal of anaesthesia. 2009 Dec;103(6):891-5.

146. GREIF R, EGGER L, BASCIANI RM, LOCKEY A, VOGT A. Emergency skill training--a randomized controlled study on the effectiveness of the 4-stage approach compared to traditional clinical teaching. Resusci-tation. 2010 Dec;81(12):1692-7.

147. WONG DT, PRABHU AJ, COLOMA M, IMASOGIE N, CHUNG FF. What is the minimum training required for successful cricothyroidotomy?: a study in mannequins. Anesthesiology. 2003 Feb;98(2):349-53.

148. PETERSON GN, DOMINO KB, CAPLAN RA, POSNER KL, LEE LA, CHENEY FW. Management of the diffi cult airway: a closed claims analysis. Anesthesiology. 2005 Jul;103(1):33-9.

Page 56: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine56

Video Systems for Airway Management

KARL STORZ offers a complete armamentarium of instruments and videoendoscopic devices, that is tailored to a wide range of airway management modalities. The broad scope of KARL STORZ products gives you all

options – for dealing with a standard or unexpectedly difficult intubation. In addition, all of our fiberscopes are powered by an LED battery light source to make sure that even in an emergency you will never be left in the dark.

E-ModuleC-MAC® S ImagerC-CAM®

OR 1™ Monitor

Laptop Airway Cockpit

C-MAC® PM

C-MAC® SVideo Laryngoscope,

for single useC-MAC®

Video Laryngoscope

FIVE(Flexible Intuba tionVideo Endoscope)

Endoscopes/Fiberscopes (eyepiece)

C-HUB®

C-MAC® Monitor

It is recommended to check the suitability of the product for the intended procedure prior to use.

Page 57: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 57

C-MAC® Video Laryngoscopefor visual endotracheal intubatio

Special Features: � Resistant ABS plastic housing � Splash-proof according to IP54 � 7" TFT wide view angle display with resolution of 800 x 480 pixels

� Ready for use within seconds � Documentation of still images (JPEG) andvideos (MPEG4) on SD memory card

� VESA 75 norm for connecting and attaching racks � Soft keys enable use within seconds � Cinch video output for connecting external monitor � System open for further components � Operating time with lithium-ion batteries of about 2 hours

� World power supply 100 – 240 VAC, 50/60 Hz � Operation with line voltage and rechargeable lithium-ion batteries

� Processing of the electronic module: Suitable and validated for the following low-temperaturereprocessing methods up to bis max. 60 °C:manual/machine cleaning and disinfection,sterilization with Steris® AMSCO V PRO 1, Sterrad® (50S, 100S, 200S, NX, 100NX) and EtO gas;High-Level Disinfection (HLD) acc. to US standards

� Additional standards:RTCA/DO-160F, EMI Test Report(German air rescue service DRF Luftrettung)

8402 ZX Monitor for CMOS Endoscopes, screen size 7", documentation can be stored directly on SD card, rechargeable Li-Ion batteries, power adaptor for EU, UK,USA and Australia, power supply 110 – 240 VAC, 50/60 Hz,additional standards: RTCA/DO-160F, EMI Test Report(German air rescue service DRF Luftrettung),suitable for wipe disinfection

8402 X8403 ZX

Monitor/Electronic Module

8402 X Electronic Module, for C-MAC® Monitor 8402 ZX,for use with C-MAC® video laryngoscopes

8401 YCA

8401 YCA VESA 75 Quick Clip, with 4 fi xation screws,for mounting C-MAC® to tube up to diameter 25 mm

Accessories included in delivery with 8402 ZX:

8403 ZX C-MAC® Monitor für CMOS Endoscopes, screen size 7"with 1280 x 800 pixel resolution, two camera inputs,a USB and a HDMI port, optimized user interface,video and image capturing in real time on SD card,playback of recorded video clips and still images, data transfer from SD card to USB fl ash drive possible,splash-proof according to IP54, suitable for wipe disinfection,shock-resistant ABS plastic housing, intelligent power management with rechargeable Li-Ion batteries,VESA 75 mounting option, power adaptor for EU, UK, USAand Australia, power supply 110 - 240 VAC, 50/60 Hz

Page 58: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine58

BERCI-KAPLAN C-MAC® Video Laryngoscopefor visual endotracheal intubation

8401 KXC/AXC/BXC

8401 AXC Same, size 3

8401 KXC BERCI-KAPLAN C-MAC® Video Laryngoscope #2, CMOS technology,with MACINTOSH laryngoscope blade, size 2, for use with ElectronicModules 8401 X and 8402 X

8401 BXC Same, size 4

8401 DXC/GXC

8401 DXC MILLER C-MAC® Video Laryngoscope, CMOS technology, size 0,for use with Electronic Modules 8401 X and 8402 X

8401 GXC Same, size 1

Special Features: � European closed laryngoscope blade design � Angle of view approx. 80° � Ergonomically designed handle � CMOS technology with LED illumination � Proximal slanted blade � Available with or without suction � Processing video laryngoscopes: suitable andvalidated for the following low-temperaturereprocessing methods up to bis max. 60 °C: manual/machine cleaning and disinfection,sterilization with Steris® AMSCO V-PRO 1, Sterrad® (50S, 100S, 200S, NX, 100NX) and EtO gas;High-Level Disinfection (HLD) acc. to US standards

� Blade tips of all blade types visible for safenavigation

MACINTOSH � For direct and indirect laryngoscopy � Original English MACINTOSH blade shape

D-BLADE � Special curved blade shape for diffi cult intubation

MILLER � For pediatrics and neonatology in the day-to-day clinical routine, teaching and training as well diffi cult airway management

Video Laryngoscope

n

n

Page 59: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 59

BOEDEKER-DÖRGES C-MAC® Video Laryngoscopefor visual endotracheal intubation

8401 AX/BX

8401 AX BOEDEKER-DÖRGES C-MAC® Video Laryngoscope #3,CMOS technology, with MACINTOSH laryngoscope blade, size 3, with catheter introduction sizes 14 – 16 Fr., for use with Electronic Modules 8401 X and 8402 X

8401 BX Same, size 4, with catheter introduction sizes 16 – 18 Fr.

8401 HX C-MAC® Video Laryngoscope D-BLADE, CMOS technology,with DÖRGES laryngoscope blade, for diffi cult intubation, with catheter introduction sizes 16 – 18 Fr.,for use with Electronic Modules 8401 X and 8402 X

8401 HX

Page 60: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine60

C-MAC® S Video Laryngoscope n

051113-10

051114-10

051113-10* BERCI-KAPLAN C-MAC® S Video Laryngoscope MAC #3, with MACINTOSH laryngoscope blade, size 3, for single use, sterile, package of 10, for use with C-MAC® Monitor 8402 ZX and C -MAC® S Imager 8402 XS

051114-10* Same, size 4

Special Features: � Blade and handle form one continuous piece:optimum protection against infections

� D-BLADE with short handle � Original English MACINTOSH blade shape � Sturdy plastic material � Compatible with C-MAC® monitor � Blade tip always under direct view for safenavigation

� Ergonomically designed handle � Compact design

C-MAC® S Imager: � Handling oriented towards hygiene � Reprocessing of the imager: suitable and validated for the following low-temperature reprocessing methods up to bis max. 60 °C: manual/machine cleaning and disinfection, sterilization with EtO gas; High-Level Disinfection (HLD) acc. to US standards

� Compatible with C-MAC® monitor � Blade can be exchanged within seconds

Video Laryngoscope for Single Use

* mtp medical technical promotion gmbh, Take-Off GewerbePark 46, D-78579 Neuhausen ob Eck, Germany

Page 61: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 61

C-MAC® S Video Laryngoscope n

051116-10

8402 XS

8402 XS C-MAC® S Imager, for C-MAC® Monitor 8402 ZX-1, suitable for manual and mechanical disinfection up to 60 °C and High-Level Disinfection (HLD) acc. to US standards, for use with C-MAC® S-Video Laryngoscopes 051113-10, 051114-10 and 051116-10

051116-10* C-MAC® S Video Laryngoscope D-BLADE, with DÖRGES laryngoscope blade, sterile, package of 10, for use with C-MAC® Monitor 8402 ZX and C- MAC® S Imager 8402 XS

* mtp medical technical promotion gmbh, Take-Off GewerbePark 46, D-78579 Neuhausen ob Eck, Germany

Page 62: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine62

C-MAC® PM – The Pocket Monitor n

Special Features: � Exchange of video laryngoscope within seconds � Compatible with all C-MAC® video laryngoscopes (D-BLADE, MACINTOSH sizes 2-4,MILLER sizes 0 & 1)

� One hour operating time � Rechargeable Li-ion battery with capacity control and intelligent power management

� High-resolution 2.4" LED display with240 x 320 pixels for optimal view

� No additional on/off buttons thanks to the“Open-to-Intubate-Display”(OTI)

� Important for preclinical use: classifi ed for protection class IPX8

� Due to the closed design, the entire pocket monitor unit can be fully immersed in disinfection solution which allows for easy and smooth reprocessing

� Suitable and validated for the followinglow- temperature reprocessing methods up to max.60 °C: manual/machine cleaning and disinfection

� Additional standard: RTCA/DO-160F

8401 XDL Charging Unit, for C-MAC® Pocket Monitor 8401 XD,with fi x integrated power supply and adaptor for EU,UK and USA, power supply 110 – 240 VAC, 50/60 Hz,suitable for wipe disinfection

8401 XDL8401 XDK

8401 XDK C-MAC® Pocket Monitor, Set, unit with LCD monitor and power supply for all C-MAC® laryngoscopes, screen size 2.4", monitor movable viatwo rotation axis, rechargeable Li-Ion batteries, 1 h operation time, 2 h charging time, power management with capacity indicator: switches off automatically after 10 min, protection class IPX8, additional standard: RTCA/DO-160F, validated for up to a max. of 60 °C, manual/mechanical cleaning and disinfection, for use with C-MAC® video laryngoscopes

including: Protection Cap

Page 63: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 63

FIVE – Flexible Intubation Video Endoscope for C-MAC® n

Special Features: � Compatible with C-MAC® monitor and C-HUB®

� Compact design � Ergonomically designed handle � Lightweight at 385 g � High image resolution � Video imaging in 4:3 format � Possible to exchange components within seconds

� Integrated LED light source � Suitable and validated for the followinglow-temperature reprocessing methods up to max. 60 °C: manual/machine cleaning and disinfection, sterilization with Sterrad® (100S, NX, 100NX)and EtO gas; High-Level Disinfection (HLD) acc. to US standards

11301 BNXK Flexible Intubation Video Endoscope 5.5 x 65, CMOS technology, with suction valve, for use withC-MAC® Monitor 8402 ZX and C-HUB® 20 2901 01Defl ection up/down: 140°/140°Direction of view: 0°Angle of view: 85°Working length: 65 cmTotal length: 93 cmWorking channel inner diameter: 2.3 mmDistal tip outer diameter: 5.5 mm

11301 BNXK

Page 64: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine64

AccessoriesFlexible Intubation Video Endoscopes

11301 CD1 Irrigation Adaptor, for machine cleaning,reusable, for Flexible Intubation Video Endoscope 11301 BNX

11301 CE1 Suction Valve, for single use, package of 20,for use with Flexible Intubation Video Endoscope 11301 BNX

10309 Bronchoscope Insertion Tube, size 4, with integrated mouthpiece, for single use, sterile, insertion length 85 mm, made from EVA, package of 10

10310 Bronchoscope Insertion Tube, size 2, with integrated mouthpiece, for single use, sterile, insertion length 65 mm,made from EVA, package of 10

29100 Plug, for LUER-Lock connector for cleaning, black, autoclavable,package of 10

11301 CFX Tube Holder, for use with Flexible Intubation Video Endoscope 11301 BNX

27677 FV Case

Accessories included in delivery:

13242 XL Leakage Tester,with bulb and manometer

11025 E Pressure Compensation Cap, for ventilation during gas sterilization

27651 B Cleaning Brush, fl exible, round,outer diameter 3 mm, for working channel diameter 1.8 – 2.6 mm, length 100 cm

8401 YZ Protection Cap, for the C-MAC® videolaryngoscope and electronic module,to protect plug contact during reprocessing,cap is reusable

Page 65: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 65

AccessoriesFlexible Intubation Video Endoscopes

11301 FF2 Adaptor for MIELE Cleaning Machines,with safety valve, for automatic leakage testof fl exible KARL STORZ endoscopes

11301 GG2 Adaptor, for cleaning and disinfecting the irrigation and working channels of fl exible endoscopes,for MIELE-ETD washer-disinfectors

11301 HH Adaptor for BHT Cleaning Machines, for automatic leakage test of fl exibleKARL STORZ endoscopes

11301 BM Adaptor, for leakage test,for Belimed washer-disinfectors

6927691 Adaptor for Two-Way Stopcock, LUER-Lock, with O2 tube connection

600007 LUER-Lock Tube Connector,male, tube diameter 6 mm

11301 KK2 Adaptor, for working channel of fl exible endoscopes, for MIELE-ETD 03 washer/disinfectorsPlease note: Adaptors 11301 FF2 and 11301 GG2 have to be ordered separately!

Optional Accessories:

11001 KL Biopsy Forceps, fl exible, spoon-shaped, round, double action jaws, diameter 1.8 mm, working length 120 cm

11002 KS Grasping Forceps, fl exible, alligator jaws, double action jaws, diameter 1.8 mm, working length 120 cm

11301 CA Leafl et Valve, for single use,package of 20

11301 CB1 Suction Valve, reusable, for use with Flexible Intubation Video Endoscope 11301 BNX

39405 AS Plastic Container for Flexible Endoscopes, specially suited for gas and hydrogen peroxide (Sterrad®) sterilization and storage, for use with one fl exible endoscope, external dimensions(w x d x h): 550 x 260 x 90 mm

Page 66: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine66

AccessoriesC-MAC® Video Laryngoscope

8401 YA Stand, for C-MAC® monitor, height 120 cm, rollable with fi vefeet and antistatic castors, crossbar 25 cm x diameter 25 mm,for positioning the monitor, with tray for laryngoscopes, dimensions (w x d x h): 30 x 20 x 10 cm

8401 YB Clamp, VESA 75 standard, for fi xation of C-MAC® monitorto round profi le with diameter 20 – 43 mm and square profi le with diameter 16 – 27 mm, for use with Monitors 8401 ZX/8402 ZX

8401 YAA Crossbar, for Stand 8401 YA, 50 cm x diameter 25 mm, or positioning C-MAC® Monitors 8401 ZX and 8402 ZX with VESA 75 Quick Clip 8401 YCA

8401 YAB Same, 70 cm x diameter 25 mm

8401 YA

8401 YB

8401 YAA8401 YAB

Page 67: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 67

AccessoriesC-MAC® Video Laryngoscope

8402 YD* Protective Bag, blue, for C-MAC® system, made of water-resistant and sturdy material, washable, separate compartments for the monitor and two C -MAC® video laryngoscopes with electronic module

809125 MAGILL Forceps, modifi ed by BOEDEKER, length 25 cm,suitable for endoscopic foreign body removal,for use with video laryngoscopes size 2 – 4

8401 YZ Protection Cap, for the C-MAC® video laryngoscope and electronic module, to protect plug contact during reprocessing, cap is reusable

Please note: The instruments displayed are not included in the sterilization and storage tray.

* Crash test carried out by Furtwangen University of Applied Sciences (Germany): C-MAC® system in a protective bag dropped from a height of 5 – 9 meters showed no noteworthy damage.

39501 LC2 Wire Tray for Cleaning, Sterilization and Storage for two C-MAC® and D-BLADE video laryngoscope blades incl. electronic module, with holder for fi xing and sealing electrical connections, external dimensions (w x d x h): 260 x 120 x 170 mm

8402 YD-1* Same, red8402 YD-2* Same, orange8402 YD-3* Same, NATO-olive

809120 MAGILL Forceps, for children, modifi ed by BOEDEKER, length 20 cm,for use with video laryngoscopes size 1 and 2

8402 YD-3

8402 YD-1

8402 YD-2

809125809120

39501 LC2 8401 YZ

n

8402 YD

Page 68: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine68

C-CAM® and C-HUB®

Nothing could be easier!

C-CAM® transforms the C-MAC® video laryngoscope intoan all-round system unit for complete airway management.The C-MAC® monitor is at the core of all imaging systems. C-CAM® is a high-grade CMOS camera withVGA resolution which can be connected to all KARLSTORZ endoscopes with eyepieces. Illumination is ensured through the Power-LED battery light sources. Consequently, this is the first battery-powered video system to guarantee high-quality documen tation. KARLSTORZ has once again proven that high quality and mobility are not mutually exclusive.

The C-HUB® is the interface for computer and/or mo ni tor connectivity. The signal from the front end is transmitted directly to a computer or monitor with the aid of the C-HUB®. The enhanced output can be directly linked to any computer via a USB/S-VHS connection. Thanks to the safety offered by galvanic isolation in the C-HUB®, medical products can now be connected to non-medical products (e.g. computer/ monitor).

C-HUB® is the perfect signal converter from C-MAC®/C-CAM® to USB or S-Video.

Page 69: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 69

C-CAM® and C-HUB®

20 2901 01 C-HUB® Camera Control Unit, for use withC-CAM® 20 2901 32, Electronic Module 8402 X or compatible CMOS video endoscopes, Interfaces:USB 2.0, S-Video output (NTSC), power socketincluding:C-HUB® Power SupplyS-Video (Y/C) Connecting CableUSB Connecting Cable

20 2901 01

20 2901 32/20 2901 31

20 2901 32 C-CAM® Camera Head, 8-pin, one-chip CMOS camera head, resolution 640 x 480, focal length f = 20 mm,compatible with C -HUB® 20 2901 01 and C-MAC® 8402 ZX

20 2901 31 C-CAM® Camera Head, 6-pin, one-chip CMOS camera head, resolution 640 x 480, focal length f = 20 mm,compatible with C -MAC® 8401 ZX

Page 70: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine70

Intubation FiberscopesEyepiece Versions

KARL STORZ provides the instruments you need to meet the special challenges of patients who cannot be intubated with conventional methods. Nasopharyngeal awake intubation is regarded as the gold standard of difficult airway management. We offer solutions for any challenge!

Our versatile intubation fiberscopes can be used in all clinical settings whether in intensive care units or emergency rooms as well as for patients with anti cipated difficult airways during induction. The various sheath diameters enable you to select the ideal instrument for your patient and allow a swift reaction thanks to the compact, flexible LED light sources.

Intubation Fiberscopes – eyepiece version, with optional LED battery light source

Special Features: � Sheath stiffness adapted to anesthesiological requirements

� Suitable for both fi ber optic intubation andbronchoscopy

� Patented sheath surface special treatmentrequires only minimal lubrication and providesoptimal tube insertion

� Developed for use in the OR, ICU, ER � Even safer tube introduction due to video-assisted control on the monitor

� Tube position of ETT, LMA, DLT can be verifi ed � Video-assisted monitoring for percutaneoustracheostomy

� Adaptable for foreign body removal or bronchial lavage

� Various outer diameters: 2.8; 3.7; 5.2 mm � Diameter of working channel ranging from1.2 to 2.3 mm

� Extremely bright, white light due to the LED light source with rechargeable Li-Ion batteries

� Intubation fi berscope can be directly connected to the C-MAC® monitor with the mobile camera head C-CAM®

� Suitable and validated for the followinglow-temperature reprocessing methods up to a max. of 60 °C: manual/mechanical cleaning and disinfection, sterilization with Steris® AMSCO V PRO 1, Sterrad® (50S, 100S, 200S, NX, 100NX)and EtO gas; High-Level Disinfection (HLD) acc. to US standards

11301 BN1

Page 71: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 71

Intubation FiberscopesEyepiece Versions

Benefi ts: � Effective suction possible via the 1.2 mmworking channel

� Suitable for use with endotracheal tubesas of 3.5 mm

� Increased stiffness and smoother passageof the ETT

� Ready for immediate use and easy to cleanand reprocess

� Optimized for use with mobile light sources � Intubation fi berscope can be connected to the C -MAC® monitor via the mobile C-CAM® camera head

� Practical tube fi xation via special adaptor

Intubation Fiberscope 11301 AA1 is ideal for use in neonatology due to its small outer diameter of 2.8 mm. This fiberscope is the only one of its size that has a working channel with 1.2 mm.

Intubation Fiberscope 11301 AA1 features a connector for suction valves for single or multiple use.

The special sheath surface combined with increased stiff ness improves the gliding properties of the ETT over standard intubation fiberscopes.

The use of a mobile LED light source enables independent work under optimal lighting conditions.

2.8 x 65 Intubation Fiberscope with optimized imaging

11301 AA1

11301 AA1 Intubation Fiberscope 2.8 x 65,Defl ection up/down: 140°/140°Direction of view: 0°Angle of view: 90°Working length: 65 cmWorking channel inner diameter: 1.2 mmDistal tip outer diameter: 2.8 mm

Page 72: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine72

Intubation FiberscopesEyepiece Versions

3.7 x 65 Intubation Fiberscope with optimized imaging

The 3.7 x 65 intubation fiberscope is a universal working in stru ment as it provides gold stand ard intu ba tion for both adult and pediatric patients. Due to its small diameter, it is an excellent tool for the placement of double lumen tubes. Using a mobile LED light source and C-CAM®, the intubation fiberscope can be directly connected to the C-MAC® monitor for a monitor-as sisted intubation solution that is both mobile and flexi ble – also suitable for electronic docu men tation.

11302 BD2 Intubation Fiberscope 3.7 x 65,Defl ection up/down: 140°/140°Direction of view: 0°Angle of view: 90°Working length: 65 cmWorking channel inner diameter: 1.5 mmDistal tip outer diameter: 3.7 mm

11302 BD2

Benefi ts: � Effective suction possible via 1.5 mmworking channel

� Suitable for use with endotracheal tubes as of 4 mm

� Increased stiffness and smoother passageof the ETT

� Practical tube fi xation via special adaptor � Ready for immediate use and easy to cleanand reprocess

� Optimized for use with mobile light sources � Intubation fi berscope can be connected to the C- MAC® monitor via the mobile C-CAM® camera head

Page 73: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 73

Intubation FiberscopesEyepiece Versions

11301 BN1

11301 BN1 Intubation Fiberscope 5.2 x 65,Defl ection up/down: 140°/140°Direction of view: 0°Angle of view: 110°Working length: 65 cmWorking channel inner diameter: 2.3 mmDistal tip outer diameter: 5.2 mm

5.2 x 65 Intubation Fiberscope with optimized imaging

The 5.2 x 65 intubation fiberscope creates an ideal bala n ce between image size, working channel size and fiber optics. Effective suction is possible via the 2.3 mm working channel. The fiberscope is also suit able for removing foreign bodies or for bronchial lavage in the intensive care unit. Using a mobile LED light source and C-CAM®, the intubation fiberscope can be directly connected to the C-MAC® monitor for a monitor-assisted intubation solution that is both mobile and flexible – also for electronic documentation.

Benefi ts: � Effective suction possible via the large 2.3 mm working channel

� Suitable for use with endotracheal tubes as of 5.5 mm

� Increased stiffness and smoother passageof the endotracheal tube

� Practical tube fi xation via special adaptor � Ready for immediate use and easy to cleanand reprocess

� Optimized for use with mobile light sources � Intubation fi berscope can be connected to the C-MAC® monitor via the mobile C-CAM® camera head

Page 74: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine74

Intubation FiberscopesEyepiece Versions

13242 XL Leakage Tester, with bulb and manometer

11301 CF LIPP Tube Holder, for intubation fi berscopes

11025 E Pressure Compensation Cap, for ventilation during gas sterilization

27651 A Cleaning Brush, fl exible, long, for working channel diameter 1.2 mm, working length 150 cm

27651 B Cleaning Brush, fl exible, round,outer diameter 3 mm, for working channel diameter 1.8 – 2.6 mm, length 100 cm

29100 Plug, for LUER-Lock connector for cleaning, black, autoclavable, package of 10

11301 CD Irrigation Adaptor, for machine cleaning,reusable, for fi berscopes

2x

11301 CE Suction Valve, for single use, package of 20

10310 Same, size 2, insertion length 65 mm

10309 Bronchoscope Insertion Tube, size 4,with integrated mouthpiece, for single use,sterile, insertion length 85 mm, made from EVA, package of 10

Accessories included in delivery:

11025 E

11301 CF 27651 A/B

13242 XL

27677 A Case

29100 11301 CD

11301 CE

10309/10310

Intu

batio

n Fi

bers

cope

s Ey

epie

ceOrder No.

Defl

ect

ion

up/d

own

Dire

ctio

n of

vie

wA

ngle

of v

iew

Wor

king

leng

thTo

tal l

engt

h

Wor

king

cha

nnel

inne

r di

amet

er

Dis

tal t

ip o

uter

dia

met

erR

ecom

men

ded

ETT

diam

eter

as

of*

11301 AA1

11302 BD2

2.8 x 65

3.7 x 65

0° 90° 65 cm

0° 90° 65 cm

98 cm 1.2 mm 2.8 mm

93 cm 1.5 mm 3.7 mm

11301 BN15.2 x 65 0° 110° 65 cm 93 cm 2.3 mm 5.2 mm

3.5 mm

4.5 mm

5.5 mm

140°

°140

140°

°140

140°

°140

Page 75: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 75

* Please note that the accuracy of the ETT diameter may vary depending on the manufacturer’s quality.

11003 MB Grasping Forceps, fl exible, double action jaws,diameter 1 mm, length 110 cm, for fl exible bronchoscopes

11003 MA Biopsy Forceps, fl exible, oval, double action jaws, diameter 1 mm, length 110 cm

Optional Accessories:

11001 KL Biopsy Forceps, fl exible, spoon-shaped, round, double action jaws, diameter 1.8 mm, working length 120 cm

11002 KS Grasping Forceps, fl exible, alligator jaws,double action jaws, diameter 1.8 mm, working length 120 cm

Cas

e

Pre

ssur

e C

ompe

nsat

ion

Cap

Leak

age

Test

er

LIP

P T

ube

Hol

der

Cle

anin

g B

rush

Plu

g

Irrig

atio

n A

dapt

or

Suct

ion

Valv

eB

ronc

hosc

ope

Inse

rtio

n Tu

beBi

opsy

For

ceps

Flex

ible

Gra

spin

g Fo

rcep

s

Accessories (included in delivery) Add. Accessories

11025 E 13242 XL 11301 CF 27651 A 11003 MA 11003 MB

11025 E 13242 XL 11301 CF 27651 A 11003 MA 11003 MB

27677 A

27677 A

27677 A 11025 E 13242 XL 11301 CF 27651 B

29100

29100

29100

2x11301 CD

2x11301 CD

2x11301 CD

11301 CE

11301 CE

11301 CE

1030910310

1030910310

10309 11001 KL 11002 KS

Intubation FiberscopesEyepiece Versions

Page 76: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine76

BONFILS Retromolar Intubation EndoscopesEyepiece Versions

Unexpected difficult airways are always a challenge inairway management. With the BONFILS intubation endoscope and its versatile intubation techniques, this situation can be brought back to a controlled status. The endotracheal tube is guided into the trachea under direct

vision and the possibility of simultaneous application of oxygen provides more safety. Moreover, KARL STORZ offers a solution to meet the most stringent hygiene requirements – the autoclavable SILVER LINE.

The expert instrument for multiple applications in airway management combines technical sophisticationwith utmost reliability

Page 77: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 77

BONFILS Retromolar Intubation EndoscopesEyepiece Versions

10332 B110330 B1

10331 B2K

10330 B1 BONFILS Retromolar Intubation Endoscope, outer diameter 5 mm,for ETT > 5.5 mm, usable sheath length 40 cm, distal bending 40°, working channel diameter 1.2 mm, including Tube Holder 10331 BA for tube fi xation and O2 application

10331 B2K BONFILS Retromolar Intubation Endoscope, autoclavable,outer diameter 5 mm, for ETT > 5.5 mm, usable sheath length 40 cm,distal bending 40°, with movable eyepiece,with Tube Holder 10331 BA for tube fi xation and O2 application

Special Features: � SILVER LINE – autoclavable � Particularly suitable for the unexpected diffi cult airway

� Use in the case of minimal mouth opening (> 1 cm) possible

� Introduction of the tube under visualization: What you see is what you get!

� Continuous O2 fl ow via tube adaptor betweentube and instrument

� One-person intubation possible

� Connect and intubate – thanks to the mobile LED “Power of Light” light source

� Quick and easy cleaning � Suitable and validated for the followinglow-temperature reprocessing methods up tobis max. 60 °C: manual/machine cleaning anddisinfection, sterilization with Steris® AMSCO V PRO 1, Sterrad® (50S, 100S, 200S, NX, 100NX)and EtO gas; High-Level Disinfection (HLD)acc. to US standards

� Recommended for video-assisted intubationwith C -CAM® to C-MAC® monitor

n

10332 B1 BONFILS Retromolar Intubation Endoscope, outer diameter 3.5 mm, for ETT 4 – 5.5 mm, usable sheath length 35 cm, distal bending 40°,with movable eyepiece, including Tube Holder 10332 BA for tube fi xation and O2 application

Page 78: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine78

BONFILS Retromolar Intubation EndoscopesEyepiece Versions

Accessories included in delivery:

27677 BM Case, internal dimensions (w x d x h): 490 x 290 x 85 mm

10332 BA Tube Holder for ETT, with O2 application connection, inner diameter 3.5 mm

27651 AE Cleaning Brush, for Intubation Endoscope 10330 B1

10332 BA/10331 BA

27651 AE

10331 BA Tube Holder, inner diameter 5 mm

27677 C Plastic Case, without inserts, internal dimensions (w x d x h): 480 x 285 x 80 mm

Intu

batio

n En

dosc

opes

Eyep

iece

Order No.

Dis

tal b

endi

ng

BONFILS3.5 x 35 10332 B1

BONFILS5 x 40 10330 B1

BONFILS5 x 40 10331 B2K

Page 79: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 79

BONFILS Retromolar Intubation EndoscopesEyepiece Versions

39501 F

39501 F Wire Tray for Cleaning, Sterilization andStorage of one rigid BONFILS endoscope,including holder for light post adaptors,silicone telescope holders and lid, external dimensions (w x d x h): 570 x 80 x 52 mm

Optional Accessories:

* Please note that the accuracy of the ETT diameter may vary depending on the manufacturer’s quality.

Ang

le o

f vie

w

Wor

king

leng

th

Tota

l len

gth

Wor

king

cha

nnel

dia

met

erD

ista

l tip

out

er d

iam

ter

Cas

e

Tube

Hol

der

Cle

anin

g B

rush

Accessories(included in delivery)

27651 AE

90° 35 cm 52 cm – 3.5 mm 27677 BM 10332 BA

110° 40 cm 52 cm 1.2 mm 5 mm 27677 C 10331 BA

–110° 40 cm 54 cm – 5 mm

Rec

omm

ende

d ET

T

diam

eter

as

of*

4 mm

5.5 mm

5.5 mm 27677 BM 10331 BA

Page 80: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine80

LIPP/GOLECKI Airway Management SetBasic Set

11300 B3 LIPP/GOLECKI Airway Management Set, for the diffi cult airway including: Intubation Fiberscope, 3.7 mm x 65 cm BONFILS Retromolar Intubation Endoscope, 5 x 40, autoclavable Battery Light Source LED for Endoscopes Mask Adaption “MAINZ Adaptor”, blue, package of 5 Laryngeal Tube, size 4 Laryngeal Tube, size 3 Spiral Tube, size 6, for single use Bronchoscope Insertion Tube, size 4 Laryngeal Mask, standard, reusable, size 1 Laryngeal Mask, standard, reusable, size 2 Laryngeal Mask, standard, reusable, size 4 Intubation Laryngeal Mask, reusable, size 3 Intubation Laryngeal Mask, reusable, size 4 Laryngeal Mask Tube, diameter 7 mm Laryngeal Mask Tube, diameter 7.5 mm LMA Tube Stabilizer MAGILL Forceps, length 25 cm Scalpel, for single use, package of 10 COTTLE Nasal Speculum, blade length 55 mm, length 13 cm DÖRGES Emergency Laryngoscope Blade, cold light, universal size Handle Sleeve, ISO 7376 Battery Insert, with 2 Batteries 121306 S and Xenon Lamp 8546 XA Case

Recommended Set for Diffi cult and Standard Intubation

Page 81: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 81

Intubation Set -C22-, ULM ModelBasic Set

n

8400 B Intubation Set -C22-, ULM model including: BOEDEKER-DÖRGES C-MAC® Video Laryngoscope, MAC #3 BOEDEKER-DÖRGES C-MAC® Video Laryngoscope, MAC #4 C-MAC® Video Laryngoscope D-BLADE C-MAC® Pocket Monitor Set Charging Unit, for C-MAC® pocket monitor Protective Cap Handle Sleeve, ISO 7376 DÖRGES Emergency Laryngoscope Blade, cold light Battery Insert Set LED, with cap Bag for Intubation Set -C22-, ULM model MAGILL Forceps, modifi ed by BOEDEKER

8402 YE Bag for Ulm Intubation Set -C22-, made of water-resistant and sturdy material, washable, including two compartments with several holding facilities for C-MAC® video laryngoscope blades with C-MAC® pocket monitor and conventional laryngoscopes, for use with C-MAC® Pocket Monitor 8401 XD, C-MAC® video laryngoscopes and conventional laryngoscopes

Page 82: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine82

Emergency Tracheobronchoscopy SetBasic Set

10330 F Emergency Tracheoscope Set including:Emergency Bronchoscope, size 6, length 30 cmEmergency Tracheoscope, size 9, length 25 cmEmergency Tracheoscope, size 7, length 20 cmEmergency Tracheoscope, size 5, length 20 cmFLUVOG AdaptorAdaptor for VentilationDÖRGES Emergency Laryngoscope Blade, cold light, universal size2x Handle Sleeve, ISO 73762x Battery Insert, with 2 Batteries 121306 S and Xenon Lamp 8546 XAXenon Lamp, package of 6Forceps, for peanuts and soft foreign bodiesForceps, alligator, for hard foreign bodiesMAGILL Forceps, length 20 cmMAGILL Forceps, length 25 cmYOUNG Tongue Seizing ForcepsSuction Tube, diameter 3 mm, length 35 cmSuction Tube, diameter 4 mm, length 35 cmSuction Tube, diameter 5.5 mm, length 35 cmCase

Recommended Set for Diffi cult and Standard Intubation

Page 83: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 83

11301 D3 Same, with coarse thread

121306 P Photo Battery, lithium, 3 V, CR 123 A

Special Features: � Battery light source with extremely high light intensity >100 lm / > 150 klx

� Available as battery and rechargeable version � Absolute white light due to LED technology � Special light focus allows optimal lightadjustment at the endoscope connector

� LED provides up to 50,000 hourslifetime

� Burning time of 120 min � Waterproof, fully immersible for cleaningand disinfection (11301 D1/D3)

11301 D1 Battery Light Source LED for Endoscopes, with fi ne screw thread, brightness > 100 lm / > 150 klx, burning time > 120 min,weight approx. 150 g, waterproof and fully immersible for manual cleaning and disinfection, with 2 Photo Batteries 121306 P

11301 DE Battery Light Source LED for Endoscopes, rechargeable, with click connection, brightness > 110 lm / >150 klx, color temperature 5500 K, lithium-ion batteries,charging time 60 min, burning time at 100% brightness 40 min, weight approx. 150 g ready for use, suitable for wipe disinfection

11301 DF Same, with fast screw thread

11301 DG Charging Unit, for 11301 DE/11301 DF, for two LED battery light sources, with fi xed integrated power supply and adaptor for EU, UK, USA and Australia, power supply 110 – 240 VAC, 50/60 Hz,suitable for wipe disinfection

11301 DH Holder, for Charging Units 11301 DG, 8546 LE and 8401 XDL

11301 D1/D3/DE/DF 11301 DG

Battery Light Source LED BRITE LITEAccessories for Intubation Fiberscopes and Endoscopes

Page 84: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine84

MACINTOSH Laryngoscope BladesCold Light, with Replaceable Fiber Optic Light Carrier

8546 8546 A8546 LD

8537 A-E

MILLER Laryngoscope BladesCold Light, Fiber Optic Light Carrier Incorporated

8537 A MILLER Laryngoscope Blade,size 4

8537 B Same, size 38537 C Same, size 28537 D Same, size 18537 E Same, size 0

8546 8546 A8546 LD

8541 AA-E

**) MJL BUCX, HM de GAST, J VELDHUIS, LH HASSING, A MEULEMANS, A KAMMEYER: The effect of mechanical cleaning andthermal disinfection on light intensity provided by fibrelight Macintosh laryngoscopes. Anaesthesia 58: 5, 461-465 (2003).

8541 A Same, size 48541 B Same, size 38541 C Same, size 28541 D Same, size 18541 E Same, size 0

8541 AA MACINTOSH Laryngoscope Blade,size 5

Special Features: � KARL STORZ blades and handles meet the highest cleaning and hygienic standards

� Chromium-plating gives the laryngo scope bladesa compact, smooth surface; edges are rounded,thus preventing the formation of microcracks,fi ssion or sharp edges which can harbour germs

� Handles are not knurled(problematic concerning hygiene),instead have an ergonomic shapeand smooth surface.

� Handles can be supplied with LED “BRITE LITE”power system with > 50.000 lux and Li-Ionrechargeable batteries.

� The KARL STORZ laryngoscope blades are the only such products currently commercially available that are autoclavable and show no noticeable reduction in light intensity, even after several hundred cleaning cycles**.

� The Xenon lamps in the fi beroptic light carriers generate a neutral white light which is 30 – 40%brighter than standard halogen light.

� Laryngoscopy blades and handles comply with theISO 7376 standard.

� On request, additional markings can be etched on the laryngoscope/handle free-of-charge(such as, e.g., “1-83-2/Case“ or „Christoph 77/Rucksack”)

Page 85: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine 85

Handles with LED Light Sourcefor Cold Light Laryngoscope Blades

8546 Handle Sleeve, ISO 7376,autoclavable, length 12 cm, for use with Battery Inserts 8546 A, 8546 LD, 8549 LD and cold light laryngoscopes

8546 8546 LD1

8546 LD1 Battery Insert, rechargeable, length 12 cm, for Handle Sleeve 8546, with high-power LED, 56 lm/> 100 klx, lithium-ion battery insert, burning time at 100% brightness 240 min, charging via Inductive Charging Unit 8546 LE

Special Features: � Rechargeable lithium-ion batteries � Extremely bright LED of more than50 lm/> 100 klx

� Absolute white light due to LED technology (5500 K)

� Small handle with photo battery

� Special lens system allows optimal light adjustment at the blade connector

� LED provides a lifetime of more than 50,000 hours � Burning time up to 240 min at 100% brightness � Charging via inductive technology � ISO 7376 compatible

8549 LDX 8548 8548 LDX1

8548 Handle Sleeve, ISO 7376, length 6 cm, auto clavable, for use with Battery Insert Set 8548 LDX

8548 LDX1 Battery Insert Set, length 6 cm, for Handle Sleeve 8548, with high-power LED, > 56 lm/> 100 klx, burning time at 100% brightness > 120 min

including:Battery Insert, high-power LEDPhoto Battery, CR 123 ACap

8549 LDX Battery Insert Set LED, length 12 cm, for Handle Sleeve 8546 and cold light laryngoscopes, with high-power LED, > 56 lm/ >100 klx, burning time at 100% brightness > 120 minincluding:Battery Insert, high-power LED2x Battery, Mignon-Cell, LR 06, 1.5 VCap

n

Page 86: AIRWAY MANAGEMENT IN - KARL STORZ · No part of this publication may be translated, reprinted ... (ARDS) will continue to ... the prevention of gastric insuffl ation

Airway Management in Critical Care Medicine86

Handles with Xenon Light Sourcefor Cold Light Laryngoscope Blades

8546 Handle Sleeve, ISO 7376, autoclavable, length 12 cm, for use with Battery Inserts 8546 A, 8546 LD, 8549 LD and cold lightlaryngoscopes

8546 8546 A

8546 A Battery Insert, length 12 cm, with 2 Batteries 121306 S and Xenon Lamp 8546 XA

121306 S Batteries, Baby-Cell, LR 14, for Battery Inserts8544 A and 8546 A, package of 2

8547 8547 A 8547 B

8547 Handle Sleeve, ISO 7376, length 12 cm,autoclavable, for use with Battery Inserts 8547 A and 8547 B

8547 A Battery Insert, length 12 cm, including 2 Batteries 121306 KS and Xenon Lamp 8546 XA

121306 KS Batteries, Mignon-Cell, LR 06, 2 Batteries 121306 K, for Battery Inserts 8545 A, 8547 A and Battery Insert Set High-Power LED 8549 LD

8547 B Rechargeable Battery Insert, length 12 cm, for Handle Sleeve 8547,with Xenon Lamp 8546 XA, charging viaInductive Charging Unit 8546 LE

8546 XC Xenon Lamp, 2.5 V, for Battery Inserts 8546 A,8547 A and 8547 B, package of 6

8546 XC Xenon Lamp, 2.5 V, for Battery Inserts 8546 A, 8547 A and 8547 B, package of 6

Especially suitable for use with blades sizes 0 and 1