airbus / fm spg 22-23 05 07 roundit v0 emi a break-through solution for emi protection of wire...

24
Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Upload: doris-hutchinson

Post on 15-Jan-2016

224 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Roundit V0 EMIA Break-through Solution

for EMI Protection of Wire Harnesses

Page 2: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Roundit V0 EMIInnovative Concept Product Presentation

Existing Solutions for EMI Protectionin Railway

Electro-Magnetic Compatibility for Railway Cables

Compatibility with Existing Connectors & Grounding Methods

Page 3: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Roundit V0 EMIInnovative Concept Product Presentation

Existing Solutions for EMI Protectionin Railway

Electro-Magnetic Compatibility for Railway Cables

Compatibility with Existing Connectors & Grounding Methods

Page 4: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Signal Cables are shielded to :

Be protected from the environment

Power Cables are shielded to :

Protect the environment

Page 5: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Roundit V0 EMIInnovative Concept Product Presentation

Existing Solutions for EMI Protectionin Railway

Electro-Magnetic Compatibility for Railway Cables

Compatibility with Existing Connectors & Grounding Methods

Page 6: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Metallic Braids

Page 7: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Metallic Braids

Difficult to install on big lengths Apertures created by installation

Page 8: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Metallic Raceways

Page 9: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Metallic Raceways

Heavy & Big Expensive solution / component & installation

Page 10: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Metallic Ribbons

Very Low EMI Performances Installation in multilayers time consuming

Page 11: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Roundit V0 EMIInnovative Concept Product Presentation

Existing Solutions for EMI Protectionin Railway

Electro-Magnetic Compatibility for Railway Cables

Compatibility with Existing Connectors & Grounding Methods

Page 12: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

From Tubular to Open

Page 13: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Construction stable whatever the length

From Changing to set EMI Results

Installation modifies the Construction

Page 14: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Provide ease of installation on long lengths

Keep construction stable whatever the diameter

Same performance as a 65% coverage sleeve

A range of sizes adapted to many applications

Reworkable-connection shielding

Compatibility with existing grounding solutions

Compatibility with metal used in the industry

Product Design

Page 15: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Used in… Roundit 2000V0

Classified I2F1 acc. to NF 16101-16102Zero halogenInherently flame retardant

Assembly

FR Polyester Monofilaments Classified V0 acc. To UL94

Tin Platted Copper Wire EN13602

Used in… Braids & Over-braiding

High conductivityGood tension propertiesApproved standard within the industry

Page 16: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Spec. Link

NFC 31-111NFC 31-111 DIN 40500-Teil 5EN 13602ASTM B33

Improved Mechanical ProtectionBetter Salt Spray Resistance

Page 17: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Shielding

-85 dB at 10.000 Hz

-50 dB at 100 MHz

Size 19

-60 dB at 100 MHzfor a 65% cov. braid

R0 = 3,8 milliohms(Calculated Value at DC)

R0 = 5,9 milliohms(Calculated Value at DC)

for a 65% cov. braid

Size 13

Page 18: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Flammability

Preliminary Test Results Flammability to BS5863

Preliminary Test Results Flammability to NF16101-16102

F1 – Waiting for I Class

Page 19: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Installation

Page 20: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Available Sizes

Page 21: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Roundit V0 EMIInnovative Concept Product Presentation

Existing Solutions for EMI Protectionin Railway

Electro-Magnetic Compatibility for Railway Cables

Compatibility with Existing Connectors & Grounding Methods

Page 22: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

ExistingSolutions

Page 23: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

Easy & EfficientGrounding

Page 24: Airbus / FM SPG 22-23 05 07 Roundit V0 EMI A Break-through Solution for EMI Protection of Wire Harnesses

Airbus / FM SPG 22-23 05 07

1

2

3

Easy & EfficientGrounding

Attachment of grounding directly

on the car body is possible

Tie-rapsfor attachmentof the bundle

Metal spring or band-it

can be usedfor grounding