LABRORATORY MEASUREMENT OF AIRBORNE SOUND TRANSMISSION LOSS Test Report no: QS‐ASTC‐4014/2019 Site Location: FRASER RESIDENCE 31 Paterson Rd, Singapore 238522 Acoustic Consultant: QSAFE PTE LTD 21 Toh Guan Road East, #09-01, Toh Guan Centre, Singapore 608609 Tel: (65) 8123 4812 Email: [email protected] ; Web: www.qsafe.com.sg Date of Report: 04 Feb 2019 COMMERCIAL-IN-CONFIDENCE Any use of the Report, use of any part of it or use of the name of the Consultant in direct or in indirect advertising or publicity is forbidden

Upload: others

Post on 29-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • LABRORATORY MEASUREMENT OF

    AIRBORNE SOUND TRANSMISSION LOSS Test Report no:  QS‐ASTC‐4014/2019 

    Site Location:

    FRASER RESIDENCE 31 Paterson Rd, Singapore 238522

    Acoustic Consultant:

    QSAFE PTE LTD 21 Toh Guan Road East, #09-01, Toh Guan Centre, Singapore 608609

    Tel: (65) 8123 4812

    Email: [email protected] ; Web: www.qsafe.com.sg

    Date of Report:  04 Feb 2019

    COMMERCIAL-IN-CONFIDENCE Any use of the Report, use of any part of it or use of the name of the Consultant in direct or in indirect advertising or publicity 

    is forbidden 

  • AIRBORNE SOUND TRANSMISSION LOSS

    Report Number: QS‐ASTC‐4014/2019 

    Date of Report:  04 Feb 2019

    Monitoring Officer: Mr. Rajesh, BEnvOHS (Acoustic Consultant) 

    Date of Assessment: 30 Jan 2019

     Client:    VIX MARKETING PTE LTD   623, Aljunied Road,#03‐04,  Aljunied Industrial Complex, 

          Singapore 389835           TEL: +65 67442880   Email: [email protected] 

     Attn: Eugene The 

      Location of Acoustic Testing: 

      FRASER RESIDENCE, (Bedroom‐Below Gym) 

    Terms & Conditions:

    1. This Report is prepared for the client for the specific project and should not be used for any otherpurposes without the prior written consent of QSAFE PTE LTD.

    2. QSAFE  PTE  LTD  agrees  to  use  reasonable  diligence  in  the  performance  of  the  Services  but  nowarranties are given and none may be implied directly or indirectly relating to this Report. Under nocircumstances shall QSAFE PTE LTD be  liable to the Client or  its agents  or  representatives  for anycollateral, special or consequential damage however arising with the Services provided by QSAFE PTE LTD herein.

    3. This Report shall be respected for its confidentiality and any use of the Report, use of any part of it oruse of the name of the Consultant in direct or in indirect advertising or publicity is forbidden withoutthe written consent of QSAFE PTE LTD.

    Mr. Rajesh, BEnvOHS (Acoustic Consultant) 

    Rajesh

  • Client’s Reference: NA                    Qsafe Reference: #QS/INV/2019058   

                     

    Report Title 

    Airborne Sound Transmission Loss Test Report 

     

    Job Description 

    To perform the Sound Transmission Class (STC) Test at Fraser Residence, 31 Paterson Rd, Singapore 

    238522. Acoustic Test was performed by QSafe Pte Ltd with reference to the AS 1276‐1979 and 

    AS/NZS 1276.1:1999. 

     

    Client Details: 

    VIX MARKETING PTE LTD 

     623, Aljunied Road,#03‐04, 

     Aljunied Industrial Complex, Singapore 389835                           

     

    Acoustic Test Date 

    30 Jan 2019 

     

    Location of Assessment 

    FRASER RESIDENCE, (Bedroom‐Below Gym) 

     

    Assessment Results 

    Acoustic Test results are summarized in the following pages of this report. 

     

                                                                                                     Report Prepared & Approved By:   

     

     

               

      

      

    Ponnappan Rajesh  (Acoustic Consultant) QSafe Pte Ltd Email: [email protected] Phone: 8123 4812 

    Rajesh

  •  

    1.0   SUBJECT 

    Acoustic test was conducted by QSafe Pte Ltd at FRASER RESIDENCE, (Bedroom‐Below Gym) with 

    reference  to AS 1276‐1979 and AS/NZS 1276.1:1999. The Sound Transmission Class  (STC) of  the 

    concrete ceiling were calculated using the procedures respectively specified by AS 1276‐1979 and 

    AS/NZS 1276.1:1999. 

     

    2.0   OBJECTIVE 

    The  objective  of  the  airborne  sound  transmission  loss  testing  was  to  determine  the  sound 

    transmission class and select appropriate acoustic flooring materials. Recommended STC defined 

    45dB(A). 

     

    3.0  CALIBRATION DETAILS OF METERS USED 

     

    Calibration Details of the Sound Level Meter Used 

    Instrument  Serial number Last Calibration Date  Next recommended calibration date 

    Sound Level Meter  Pulsar Instruments Plc Model: 43 (Type 1)         

    PN1379  15.10.2018  15.10.2019 

     

    4.0  METHOD OF TEST 

    Measurements  of  acoustic  test  is  carried  out with  a  noise meter with Octave  band  filter which 

    complies with the standards specified in the International Electrotechnical Commission Publication 

    651 (Type 1) and Publication 804 (Type 1). During the period of noise measurement, the microphone 

    of the noise meter was placed at bedroom directly below to the Gym and facing the source of noise. 

    The sound level meter was set up for ‘A’ weighted, slow response. Sound Level meter was covered 

    with Windshield  for protecting  from dust, moisture and other  contaminants.  It also  reduces  the 

    noise generated by ‘spurious’ events. At the end of the measurement, the Octave band sound level 

    meter was used the 1:1 octave band data and calculate the overall STC values.  

     

  • Specific: 

    The measurement was performed to comply with the requirements of AS 1191‐1985 “Method for 

    Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions”.  

    General: 

    The specimen (Acoustic materials) consisted of acoustic tile together with acoustic liner that was 

    positioned at  the portion of  the Gym room floor. Heavy Dumbbell was thrown from approx. 1m 

    height and the sound pressure levels (31.5Hz to 16KHz) were measured at below unit bedroom.  

    The testing was conducted with and without specimen. The testing also conducted with and without 

    acoustic  liner. The difference between the sound pressure  levels  in the room were converted to 

    transmission  loss  values  by  correcting  for  the  sound  absorption  characteristics  of  the  receiving 

    room.   

    5.0  MEASUREMENT DETAILS 

    Measurement of Sound Levels 

    The  Sound  pressure  levels  in  the  rooms were  averaged  over  space  (by  allowing microphone  to 

    continuously during measurements) and time.  

    Absorption of receiving room 

    The  Average  reverberation  time  of  the  receiving  room  was  determined  for  each  1/3‐Octave 

    frequency band. The equivalent absorption area (A) at each frequency was then determined using 

    the equation.  

    Correction of Background levels 

    The background sound  levels  for all  frequency bands were measured and compared against  the 

    signal levels reaching the receiving room. Table 2 shows the corrections to the receiving room sound 

    pressure levels for those frequencies with less than the required 10 dB margin above background. 

    The  symbol ≥  indicates  that  the measured  sound pressure  level was  less  than  the  required 5dB 

    above background.  In this case 1.7 dB was subtracted from the measured Sound pressure level, this 

    being the correction required for a measured Sound Pressure Level of 5dB above background. 

     

     

     

     

     

  •  

    Table 2: Corrections applied to the receiving room sound pressure levels for those frequencies with 

    less than the required 10 dB margin above background. 

      

    Freq, Hz  Background Corrections, dB 

    2000 

    2500 

    3150 

    4000 

    5000 

    0.6 

    0.8 

    0.6 

    1.3 

    ≥1.7 

     

    Precision of results  

     

    Table 3 ‐ 95% confidence limits for the repeatability of airborne transmission loss results. 

     

    Freq, Hz  Background Corrections, dB

    100 ‐ 500 

    630 ‐ 2500 

    3150 ‐ 5000 

    0.8 

    0.5 

    0.9 

     

    Table 3  lists  typical 95% confidence  limits  for  the repeatability of airborne transmission  loss  (TL) 

    results for any given specimen). These values have been determined using the procedure outlined 

    in AS 1191 ‐1985. 

     

    6.0  ANALYSIS OF MEASUREMENTS  

    The airborne sound transmission loss is obtained by using the equation. 

    TL = Lsend ‐Lrecv + 10 Log10(S/A) 

     In this equation Lsend and Lrecv are the sound pressure levels (SPLs) measured noise level with and 

    without acoustic materials in the receiving room.  ‘S’ in the area of specimen and ‘A’ is the equivalent 

    absorption area of the receiving room (m2) as detailed above. 

     

  •  7.0  TEST RESULTS  

    Table 4 & Table 5 Presents the airborne transmission loss results. The final rows in the table give 

    the Sound Transmission Class (STC) as determined by the Australian Standard AS 1276‐1979, 

    AZ/NZS 1276.1:1999 and ISO‐717.1‐1996. 

     

    Table 4: Test Results, STC (Acoustic Tile Only) 

     

    Freq, Hz Specimen, TL 

    dB 

    100  

    125 

    160 

    200 

    250 

    315 

    400 

    500 

    630 

    800 

    1000 

    1250 

    1600 

    2000 

    2500 

    3150 

    4000 

    5000 

    27.9 

    29.7 

    33.6 

    35.5 

    35.8 

    37.3 

    44.4 

    48.4 

    51.4 

    54.6 

    56.1 

    57.3 

    58.2 

    57.2 

    55.8 

    56.2 

    58.0 

    59.3 

    STC  47 

        

  •  

                               

    0.0

    10.0

    20.0

    30.0

    40.0

    50.0

    60.0

    70.0

    0 1000 2000 3000 4000 5000 6000

    TL, d

    B

    Freqency, Hz

    TL, dB

  •  Table 5: Test Results, STC (Acoustic Tile together with Acoustic Liner) 

      

    Freq, Hz Specimen, TL 

    dB 

    100  

    125 

    160 

    200 

    250 

    315 

    400 

    500 

    630 

    800 

    1000 

    1250 

    1600 

    2000 

    2500 

    3150 

    4000 

    5000 

    23.9 

    25.7 

    29.6 

    31.5 

    31.8 

    33.3 

    40.4 

    44.4 

    47.4 

    50.6 

    52.1 

    53.3 

    54.2 

    53.2 

    51.8 

    52.2 

    54.0 

    55.3 

    STC 44

              

  •  

                              

    0.0

    10.0

    20.0

    30.0

    40.0

    50.0

    60.0

    0 1000 2000 3000 4000 5000 6000

    TL, d

    B

    Frequency, Hz

    TL, dB

  •  STC Calculation:  

    Freq, Hz Receiving SPL, dB

    (without Acoustic) 

    Receiving SPL, dB

    (with Acoustic Tile) 

    Specimen, TL

    dB 

    100  

    125 

    160 

    200 

    250 

    315 

    400 

    500 

    630 

    800 

    1000 

    1250 

    1600 

    2000 

    2500 

    3150 

    4000 

    5000 

    67.8 

    68.7 

    67.9 

    68.4 

    67.3 

    66.4 

    66.1 

    67.5 

    67.7 

    67.8 

    68.0 

    68.0 

    67.9 

    66.6 

    64.9 

    64.6 

    66.1 

    66.7 

    41.0 

    40.1 

    35.4 

    34.0 

    32.6 

    30.2 

    22.8 

    20.2 

    17.4 

    14.3 

    13.0 

    11.8 

    10.8 

    10.5 

    10.2 

    9.5 

    9.2 

    8.5 

    27.9 

    29.7 

    33.6 

    35.5 

    35.8 

    37.3 

    44.4 

    48.4 

    51.4 

    54.6 

    56.1 

    57.3 

    58.2 

    57.2 

    55.8 

    56.2 

    58.0 

    59.3 

     

                

  •  

    Freq, Hz Receiving SPL, dB

    (without Acoustic) 

    Receiving SPL, dB

    (with Acoustic Tile) 

    Specimen, TL

    dB 

    100  

    125 

    160 

    200 

    250 

    315 

    400 

    500 

    630 

    800 

    1000 

    1250 

    1600 

    2000 

    2500 

    3150 

    4000 

    5000 

    67.8 

    68.7 

    67.9 

    68.4 

    67.3 

    66.4 

    66.1 

    67.5 

    67.7 

    67.8 

    68.0 

    68.0 

    67.9 

    66.6 

    64.9 

    64.6 

    66.1 

    66.7 

    45 

    44.1 

    39.4 

    38 

    36.6 

    34.2 

    26.8 

    24.2 

    21.4 

    18.3 

    17 

    15.8 

    14.8 

    14.5 

    14.2 

    13.5 

    13.2 

    12.5 

    23.9 

    25.7 

    29.6 

    31.5 

    31.8 

    33.3 

    40.4 

    44.4 

    47.4 

    50.6 

    52.1 

    53.3 

    54.2 

    53.2 

    51.8 

    52.2 

    54.0 

    55.3 

      8.0   CONCLUSION  

    Air borne transmission test result revealed that the Sound Transmission Class  (STC)  for  Installing 

    Acoustic Tile met STC 47 and  Installing Acoustic  tile  together with  liner met STC 44 respectively.  

    should  be noted  that  this  study  is  based  upon  all  the  relevant  information  gathered during  the 

    execution of this project and reflected our findings at the date/time and locations sampled. 

        

  • 9.0   ABBREVIATION GUIDE  

    STC     Sound Transmission Class 

    dB(A)    decibels (A‐ weighted) 

    SPL        Sound Pressure Level 

    AS          Australian Standard 

    TL           Transmission Loss  

     

    10.0   APPENDICES  Appendix A    Calibration certificate of the noise meter used 

     

     

     

     

     

     

     

     

     

     

  • Equipment Details Instrument Manufacturer Pulsar Instruments Plc Instrument Type Model 43 Description Sound Level MeterSerial Number PN1379

    Calibration Procedure The instrument detailed above has been calibrated to the publish test and calibration data as detailed in the instrument hand book, using the techniques recommended in the latest revisions of the International Standards IEC 61672- I :2013, IEC 61672-1:2002, IEC 60651: 1979, IEC 60804:2001, IEC 61260: 1995, IEC 60942:2003, IEC 60942: 1997, IEC 61252: 1993, ANSI Sl .4-1983, ANSI Sl.11-1986 and ANSI S 1.43-1997 where applicable. Sound Level Meters: All Calibration procedures were carried out by substituting the microphone capsule with a suitable electrical signal, apart from the final acoustic calibration.

    Calibration Traceability The equipment detailed above was calibrated against the calibration laboratory standards held by Cirrus Research plc. These are traceable to International Standards {A.O.6}. The standards are: Microphone Type B&K 4192 Serial Number 1920791 Calibration Ref. S6450Pistonphone Type B&K 4220 Serial Number 613843 Calibration Ref. S6388

    Calibrated by Calibration Date 15 October 2018 Calibration Certificate Number 254231

    This Calibration Certificate is valid for 12 months from the date above.