air sampling techniques
TRANSCRIPT
s.no TYPES OF CHEMICAL123456789
1011121314151617181920212223242526272829303132333435363738394041424344454647
(Aqua Regia Ashing)1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE1-NITROPYRENE IN DIESEL PARTICULATES1-OCTANETHIOL2,4-D2-NITROPROPANEACETALDEHYDE by HPLCACETIC ACIDACETIC ANHYDRIDEACETONITRILEACIDS, INORGANICALCOHOLS COMBINEDALCOHOLS IIALCOHOLS IIIALCOHOLS IVALIPHATIC ALDEHYDESALKALINE DUSTSAMINES, ALIPHATICAMINES, AROMATICAMINOETHANOL COMPOUNDS IAMINOETHANOL COMPOUNDS IIAMMONIAANILINE, o-TOLUIDINE, AND NITROBENZENEantimony* chromium* lithium potassium tin zirconium*arsenic cobalt magnesium selenium titaniumARSENIC TRIOXIDEbarium copper manganese silver tungsten*beryllium iron* molybdenum strontium vanadiumBROMINEcadmium lanthanum nickel tellurium yttriumCHLORINATED AND ORGANONITROGEN HERBICIDESCHLOROACETIC ACID CHROMIUM, HEXAVALENTCRESOL (all isomers) and PHENOLDIAZOMETHANEDICHLOROFLUOROMETHANEDYES, BENZIDINE-, o-TOLIDINE-, o-DIANISIDINEELEMENTS by ICP 7301ESTERS 1ETHYL ACETATEETHYL BROMIDEETHYL CHLORIDEETHYL ETHERETHYLENE CHLOROHYDRINETHYLENIMINEFLUORIDES, aerosol and gasFORMALDEHYDE
484950515253545556575859606162636465666768697071727374757677787980818283848586878889909192939495
FORMALDEHYDE by GCFORMIC ACIDGLUTARALDEHYDEGLYCOL ETHERSGLYCOLSHEXACHLORO-1,3-CYCLOPENTADIENEHEXACHLOROBUTADIENEHYDRAZINEHYDROCARBON HALOGENATEDHYDROCARBONS, AROMATICHYDROGEN CYANIDEHYDROGEN SULFIDEHYDROQUINONEISOCYANATESISOCYANATES, MONOMERICISOPHORONEISOPROPYL ACETATEISOPROPYL ETHERKEPONEKETONES ILEAD by Flame AASLEAD in Air by Chemical Spot TestLEAD SULFIDEMERCAPTANS, METHYL-, ETHYL-, and n-BUTYLMETHANOLMETHYL AND ETHYL METHACRYLATEMETHYL BROMIDEMETHYL CELLOSOLVE ACETATEMETHYL CHLORIDEMETHYL ETHYL KETONMETHYL ETHYL KETONE PEROXIDEMETHYL IODIDEMETHYL tert-BUTYL ETHERMETHYLENE CHLORIDEMETHYLTIN CHLORIDESMONOMETHYLANILINEMONOMETHYLHYDRAZINENAPHTHASNAPHTHASNAPHTHYLAMINES, a and bNICKEL CARBONYLNICOTINENITRIC OXIDE and NITROGEN DIOXIDENITROAROMATIC COMPOUNDSNITROETHANENITROGLYCERINNITROMETHANENITROSAMINES
96979899
100101102103104105106107108109110111112113114115116117118119120121122123124125126
NITROUS OXIDEOIL MIST, MINERALORGANONITROGEN PESTICIDESORGANOPHOSPHORUS PESTICIDESPHENYL ETHERPHENYL GLYCIDYL ETHERPHOSPHINEp-NITROANILINEPOLYCYCLIC AROMATIC COMPOUNDS, TOTAL (PACsPOLYNUCLEAR AROMATIC HYDROCARBONSPOLYNUCLEAR AROMATIC HYDROCARBONSPROPYLENE DICHLORIDEPROPYLENE OXIDEQUARTZ in coal mine dust, by IR (redeposition)SILICA, CRYSTALLINE,SULFUR DIOXIDESULFURYL FLUORIDESUPER ABSORBENT POLYMERSTRIBUTYL PHOSPHATETRICHLOROETHYLENETRIFLUOROBROMOMETHANETUNGSTEN (soluble and insoluble)VANADIUM OXIDESVINYL ACETATEVINYL BROMIDEVINYL CHLORIDEVINYLIDENE CHLORIDEVOLATILE ORGANIC COMPOUNDSWARFARINZINC and compounds, as ZnZINC OXIDE
TYPES OF CHEMICAL1 HYDROCARBON HALOGENATED
2 ALCOHOLS III
3 ALCOHOLS COMBINED
5 ACETIC ACID
6 CHLOROACETIC ACID
7 VOLATILE ORGANIC COMPOUNDS
8 KETONES I
9 ACETIC ANHYDRIDE
10 ACETALDEHYDE by HPLC
11 POLYNUCLEAR AROMATIC HYDROCARBONS
12 GLYCOLS
13 ORGANOPHOSPHORUS PESTICIDES
14 BROMINE
15 AMMONIA
16 1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE
17 TRIFLUOROBROMOMETHANE
18 TUNGSTEN (soluble and insoluble)
19 TRICHLOROETHYLENE
20 TRIBUTYL PHOSPHATE
SILICA, CRYSTALLINE,21
22 SULFUR DIOXIDE
23 SULFURYL FLUORIDE
24 POLYCYCLIC AROMATIC COMPOUNDS, TOTAL (PACs
25 SUPER ABSORBENT POLYMERS
26 GLYCOL ETHERS
27 PROPYLENE DICHLORIDE
28 QUARTZ in coal mine dust, by IR (redeposition)
29 ALIPHATIC ALDEHYDES
30 PHENYL GLYCIDYL ETHER
31 PHENYLHYDRAZINE
32 CRESOL (all isomers) and PHENOL
33 PHENYL ETHER
34 PHOSPHINE
35 ORGANONITROGEN PESTICIDES
36 OIL MIST, MINERAL
37 1-OCTANETHIOL
38 VOLATILE ORGANIC COMPOUNDS
39 p-NITROANILINE
40 NITROUS OXIDE
41 NITROSAMINES
42 1-NITROPYRENE IN DIESEL PARTICULATES
43 2-NITROPROPANE
44 NITROMETHANE
45 NITROGLYCERIN
46 NITROETHANE
47 ANILINE, o-TOLUIDINE, AND NITROBENZENE
48 NITROAROMATIC COMPOUNDS
49 NITRIC OXIDE and NITROGEN DIOXIDE
50 NICOTINE
51 NICKEL CARBONYL
52 NAPHTHYLAMINES, a and b
53 NAPHTHAS
54 METHYL tert-BUTYL ETHER
55 METHYL ETHYL KETONE PEROXIDE
56 MONOMETHYLHYDRAZINE
57 MONOMETHYLANILINE
58 METHYLTIN CHLORIDES
59 METHYL IODIDE
60 METHYL ETHYL KETON
61 METHYL CHLORIDE
62 METHYL BROMIDE
63 METHYL AND ETHYL METHACRYLATE
64 METHYL CELLOSOLVE ACETATE
65 METHANOL
66 LEAD SULFIDE
67 ELEMENTS by ICP 7301(Aqua Regia Ashing)antimony* chromium* lithium potassium tin zirconium*arsenic cobalt magnesium selenium titaniumbarium copper manganese silver tungsten*
beryllium iron* molybdenum strontium vanadiumcadmium lanthanum nickel tellurium yttrium
68 ALKALINE DUSTS
69 LEAD in Air by Chemical Spot Test
70 LEAD by Flame AAS
71 KEPONE
72 NAPHTHAS
73 ISOPHORONE
74 ISOPROPYL ETHER
75 ISOPROPYL ACETATE
76 ISOCYANATES, MONOMERIC
77 ALCOHOLS II
78 HEXACHLOROBUTADIENE
79 HEXACHLORO-1,3-CYCLOPENTADIENE
80 HYDROQUINONE
81 HYDROGEN SULFIDE
82 HYDROGEN CYANIDE
83 HYDRAZINE
84 ISOCYANATES
85 ISOCYANATES
86 GLUTARALDEHYDE
87 FORMALDEHYDE by GC
88 POLYNUCLEAR AROMATIC HYDROCARBONS
89 FLUORIDES, aerosol and gas
90 FORMIC ACID
91 FORMALDEHYDE
92 PROPYLENE OXIDE
93 ETHYL BROMIDE
94 MERCAPTANS, METHYL-, ETHYL-, and n-BUTYL
95 ETHYL ETHER
96 ETHYLENIMINE
97 ESTERS 1
98 ETHYLENE CHLOROHYDRIN
99 HYDROCARBONS, AROMATIC
100 ETHYL CHLORIDE
ETHYL ACETATE101
102 ALCOHOLS IV
AMINOETHANOL COMPOUNDS I103
104 DYES, BENZIDINE-, o-TOLIDINE-, o-DIANISIDINE
105 DICHLOROFLUOROMETHANE
AMINES, ALIPHATIC106
107 AMINOETHANOL COMPOUNDS II
METHYLENE CHLORIDE108
109 DIAZOMETHANE
CHLORINATED AND ORGANONITROGEN HERBICIDES110
111 2,4-D
112 CHROMIUM, HEXAVALENT
113 ACIDS, INORGANIC
114 ACETONITRILE
115 ARSENIC TRIOXIDE
VINYL CHLORIDE
VINYL BROMIDE
VINYLIDENE CHLORIDE
VINYL ACETATE
AMINES, AROMATIC
WARFARIN
ZINC and compounds, as Zn
ZINC OXIDE
VANADIUM OXIDES
SOBRENT TYPES FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mgSOLID SORBENT TUBE 0.01 to 0.2 L/min(Coconut shell charcoal, 100 mg/50 mg)SOLID SORBENT TUBE 0.01 to 1.0 L/min(coconut shell charcoal, 100 mg/50 mg)SOLID SORBENT TUBE 0.05 to 0.2 L/min(silica gel, 100 mg/50 mg)THERMAL DESORPTION TUBE (multi-bed sorbent tubes containing graphitized carbons and carbon molecular sieve sorbents [See Appendix])
SOLID SORBENT TUBE 0.01 to 0.2 L/min(Anasorb CMS, 150 mg/75 mg)
LIQUID IN BUBBLER 0.2 to 1.0 L/min(mixed bubbler with 10 mL alkalinehydroxylamine)
LIQUID IN BUBBLER(midget bubbler containing 15 mL 0.1 to 0.5 L/minGirard T solution @ pH 4.5)
FILTER + SORBENT TUBE(37-mm, 2-μm, PTFE + washed XAD-2, 100 2 L/minmg/50 mg)
XAD-7 OVS tube(glass fiber filter, 13-mm; XAD-7, 0.5 to 2 L/min200mg/100mg)
0.2 to 1 L/min13-mm quartz filter; XAD-2, 270 mg/140 mg
PREFILTER + FILTER 0.3 to 1 L/min(PTFE, 0.5-μm + silver membrane,25-mm, 0.45-μm)
SOLID SORBENT TUBE(sulfuric acid-treated silica gel) 0.1 to 0.2 L/min
FILTER/SOLID SORBENT TUBE (OVS-2 tube:
A 0.8-micron MCE prefilter may be used toremove particulate interferences.
SOLID SORBENT TUBE 0.01 to 0.05 L/min(coconut shell charcoal, 100 mg/50 mg
SOLID SORBENT TUBES 0.01 to 0.05 L/min(two coconut shell charcoal tubesin series, 400 mg/200 mg and100 mg/50 mg)
FILTER 1 to 4 L/min(0.8-μm cellulose ester membrane
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
1 to 3 L/min
cassettes in series
CYCLONE + FILTER HD cyclone: 2.2 L/min;(10-mm cyclone, nylon or Higgins- nylon cyclone: 1.7 L/minDewell (HD) + 0.8-:m MCE or 5-:mPVC)
FILTER + TREATED FILTER 0.5 to 1.5 L/min(cellulose + Na2CO3; preceded by0.8-μm cellulose ester membrane)
SOLID SORBENT TUBE 0.05 to 0.1 L/min(coconut shell charcoal, 800 mg/200 mg)
FILTER + SOLID SORBENT 1 to 2 L/min(2-μm, 37-mm, PTFE filter + washedXAD-2 resin, 100/50 mg )
MEMBRANE FILTER 1 to 3 L/min(PVC, 5-μm, 37-mm)
SOLID SORBENT TUBE 0.1 to 0.2 L/min(Anasorb® 747, 140 mg/70 mg)
SOLID SORBENT TUBE(petroleum charcoal, 100 mg/50 mg) 0.01 to 0.2 L/min
FILTER (0.8-μm mixed cellulose estermembrane); above 23 C, use two filter
CYCLONE + PREWEIGHED FILTER (10-mm HD cyclone: 2.2 L/mincyclone, nylon or Higgins-Dewell (HD), and nylon cyclone: 1.7 L/minPVC filter, 37-mm, 5-μm)
CARTRIDGE (containing silica gel 0.1 to 1.5 L/mincoated with acidified 2,4-dinitrophenylhydrazine)
SOLID SORBENT TUBE 0.01 to 1 L/min(coconut shell charcoal; 100 mg/50 mg)
GLASS MIDGET BUBBLER 0.2 to 1 L/min(containing 15 mL 0.1 M hydrochloricacid)
SOLID SORBENT TUBE(XAD-7, 100 mg/50 mg) 0.01 to 0.1 L/min
CHARCOAL TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
SORBENT TUBE 0.01 - 0.2 L/min(Hg(CN)2-coated silica gel, 300 mg/150 mg)
FILTER/SOLID SORBENT TUBE 0.1 to 1 L/min (OVS-2 Tube: 13-mm quartz fiber filter; XAD-2,270 mg/140 mg)
MEMBRANE FILTER 1 to 3 L/min(37-mm diameter, 0.8-:m MCE, 5-:mPVC, 2-:m PTFE, or glass fiber)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(Tenax-GC, 100 mg/50 mg)
THERMAL DESORPTION TUBE TECHNIQUE 0.01 to 0.05 L/min(multi-bed sorbent tubes containing graphitized carbons and carbon molecularsieve sorbents
FILTER 1 to 3 L/min(0.8 μm mixed cellulose ester membrane
AMBIENT AIR OR BAG SAMPLE
SOLID SORBENT TUBE 0.2 to 2 L/min(Thermosorb/N™ air sampler
FILTER 1.0 to 2.0 L/min(Glass Fiber, 37-mm)
SOLID SORBENT TUBE 0.01 to 0.05 L/min(Chromosorb 106, 100 mg/50 mg)
SOLID SORBENT TUBE 0.01 to 0.05 L/min(Chromosorb 106, 600 mg/300 mg)
SOLID SAMPLER TUBE(Tenax-GC, 100 mg/50 mg) 0.2 to 1.0 L/min
SOLID SORBENT TUBES(XAD-2, 600 mg + 300 mg) 0.01 to 0.05 L/min
FILTER + SOLID SORBENT(Glass fiber filter, sulfuric acid treated + 0.2 L/minsilica gel sorbent tube, 520/260 mg)
SOLID SORBENT TUBE 0.01 to 0.02 L/min(Silica gel, 150 mg/75 mg)
SORBENT TUBES NO: 0.025 L/min(oxidizer + 2 triethanolamine-treated NO2: 0.025 - 0.2 L/minmolecular sieve)
SOLID SORBENT TUBE 1.0 L/minXAD-2 (100 mg/50 mg)
PREFILTER + SOLID SORBENT TUBE 0.05 to 0.2 L/min(low-Ni charcoal, 120 mg/60 mg;0.8-μm cellulose ester membrane
FILTER + SOLID SORBENT 0.2 to 0.8 L/min(glass fiber + silica gel, 100 mg/50 mg)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
SOLID SORBENT TUBES 0.1 to 0.2 L/min(two charcoal tubes in series; front 400 mg;back 200 mg)
IMPINGER 0.5 to 2 L/min(15 mL dimethyl phthalate)
BUBBLER 0.5 to 1.5 L/min(0.1 M hydrochloric acid)
MIDGET BUBBLER 0.2 to 1.0 L/min(0.05 M sulfuric acid, 10 mL)
FILTER + SORBENT TUBE 0.25 to 1 L/min(OVS Tube: 13-mm glass fiber filter; XAD-2,270/140 mg)
SOLID SORBENT TUBE 0.01 to 1 L/min(coconut shell charcoal, 100 mg/50 mg)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(beaded carbon, ~150 mg/~75 mg)
SOLID SORBENT TUBES 0.01 to 0.1 L/min(two coconut shell charcoal tubes in series, 400mg/200 mg and 100 mg/50 mg)
SOLID SORBENT TUBES 0.01 to 0.1 L/min(two petroleum charcoal tubes, 400 mg and200 mg; drying tube, 9-g Na2SO4,necessary at humidity >50%)
SOLID SORBENT TUBE 0.01 to 0.05 L/min(XAD-2, 400/200 mg)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
SOLID SORBENT TUBE 0.02 to 0.2 L/min(silica gel, 100/50 mg)
CYCLONE + FILTER HD cyclone: 2.2 L/min(10-mm nylon or Higgins-Dewell (HD) cyclone nylon cyclone: 1.7 L/min
FILTER 1 to 4 L/min(0.8-μm, cellulose ester membrane, or5.0-μm, polyvinyl chloride membrane
FILTER 1 to 4 L/min(1-μm PTFE membrane)
FILTER 2 L/min(0.8-μm cellulose ester membrane)
FILTER 1 to 4 L/min(0.8-μm cellulose ester membrane
FILTER + IMPINGER 0.5 to 1 L/min(0.8-μm cellulose ester membrane+ impinger with 0.1 M NaOH)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg
SOLID SORBENT TUBE 0.01 to 1 L/min(petroleum-based charcoal,100 mg/50 mg)
Solid Sorbent Tube 0.01 to 0.05 L/min(coconut shell charcoal; 100 mg/50 mg)
SOLID SORBENT TUBE 0.02 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg,
IMPINGER 1 L/min(solution of 1-(2-methoxyphenyl)-piperazine intoluene)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
SOLID SORBENT TUBE 0.05 to 0.2 L/min(XAD-2; 100 mg/50 mg)
SOLID SORBENT TUBE(2 tubes, Porapak T, 75 mg and 25 mg) 0.01 to 0.2 L/min
FILTER 1 to 4 L/min(0.8-μm cellulose ester membrane
FILTER + SOLID SORBENT TUBE 0.1 to 1.5 L/min
(Zefluor, 0.5 μm; coconut shell -RECOMMENDED: 0.2 L/mcharcoal, 400 mg/200 mg
SOLID SORBENT TUBE 0.05 to 0.2 L/min(soda lime, 600 mg/200 mg)
BUBBLER 0.2 to 1.0 L/min(15 mL 0.1 M HCl)
IMPINGER 1 to 2 L/min(tryptamine/DMSO; 20 mL)
IMPINGER 1 to 2 L/min(tryptamine/DMSO; 20 mL)
SOLID SORBENT TUBE 0.05 to 0.5 L/min(silica gel coated with 2,4-dinitrophenylhydrazineHCl, 300 mg/150 mg
SOLID SORBENT TUBE 0.01 to 0.10 L/min(10% (2-hydroxymethyl)piperdine onXAD-2, 120 mg/60 mg
FILTER + SORBENT 2 L/min(2-μm, 37-mm PTFE + washed XAD-2,100 mg/50 mg)
FILTER + TREATED PAD(0.8-μm cellulose ester membrane + 1 to 2 L/minNa2CO3-treated cellulose pad)
FILTER + SOLID SORBENT TUBE 0.05 to 0.2 L/min(PTFE membrane, 5-μm + washed, silicagel, 400 mg/200 mg)
CARTRIDGE 0.03 to 1.5 L/min(Cartridge containing silica gel coated with2,4-dinitrophenylhydrazine)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
FILTER 0.1 to 0.2 L/min
(glass fiber, 37-mm, impregnated withmercuric acetate)
Solid Sorbent Tube 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
BUBBLER 0.2 L/min(Folin's reagent
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg
SOLID SORBENT TUBE 0.01 to 0.2 L/min(petroleum charcoal, 100 mg/50 mg)
SOLID SORBENT TUBE(coconut shell charcoal, 100 mg/50 mg)
SOLID SORBENT TUBES(2 coconut shell charcoal tubes, 0.02 to 0.05 L/min400 mg and 200 mg)
SOLID SORBENT TUBE 0.01 to 0.2 L/minute(coconut shell charcoal, 100 mg/50 mg)
SOLID SORBENT TUBE 0.01 to 0.05 L/min(Coconut shell charcoal, 100 mg/50 mg)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(silica gel, 300 mg/150 mg)
FILTER 1 to 3 L/min(5-μm PTFE membrane
SOLID SORBENT TUBES 0.01 to 0.05 L/min(2 coconut shell charcoal tubes,400 mg and 200 mg)
SOLID SORBENT TUBE 0.01 to 1.0 L/min(silica gel, 150 mg / 75 mg)
IMPINGER 0.5 to 1 L/min(15 mL 2 mM hexanesulfonic acid)
SOLID SORBENT 0.01 to 0.2 L/min(2 coconut shell charcoal tubes, 100/50 mg
SOLID SORBENT TUBE 0.2 L/min(octanoic acid-coated XAD-2 resin,100 mg/50 mg)
FILTER/SOLID SORBENT TUBE 0.2 to 1 L/min(OVS tube: 11-mm quartz filter; XAD-2)
FILTER 1 to 3 L/min(glass fiber, binderless
FILTER 1 to 4 L/min(5.0-μm PVC membrane)
SOLID SORBENT TUBE 0.2 to 0.5 L/min(washed silica gel, 400 mg/200 mg withglass fiber filter plug)
SOLID SORBENT TUBE(coconut shell charcoal, 400/200 mg) 0.01 to 0.2 L/min
FILTER 1 to 3 L/mi(Na2CO3-impregnated, 0.8-μm celluloseester membrane + backup pad)
SOLID SORBENT TUBE 0.05 L/min(2 tandem tubes, each with 150 mg activatedcoconut charcoal)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 400 mg/200 mg)
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
SOLID SORBENT TUBE 0.1 to 0.2 L/min(carbon molecular sieve; 160 mg/80 mg;ORBO-92 or equivalent)
SOLID SORBENT TUBE(silica gel, 150 mg/75 mg)
FILTER 1 to 4 L/min(1-μm PTFE membrane)
FILTER 1 to 3 L/min(0.8-μm cellulose ester membrane
FILTER 1 to 3 L/min(0.8-μm PVC membrane, 25-mm diameter, inopen-face cassette)
CYCLONE + FILTER HD cyclone: 2.2 L/min(10-mm cyclone or Higgins-Dewell (HD) + nylon cyclone: 1.7 L/min5-μm PVC membrane)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
ION CHROMATOGRAPHY,CONDUCTIVITY DETECTION
GAS CHROMATOGRAPHY, FID
VISIBLE ABSORPTIONSPECTROPHOTOMETRY
HPLC, UV
HPLC, FLUORESCENCE/UVDETECTION
GAS CHROMATOGRAPHY, FID
GC, FLAME PHOTOMETRIC DETE
ION CHROMATOGRAPHY,CONDUCTIVITY
VISIBLE ABSORPTION
SPECTROPHOTOMETRY
GAS CHROMATOGRAPH, FID
GAS CHROMATOGRAPHY, FID
ATOMIC ABSORPTION, FLAME
GAS CHROMATOGRAPHY, FID
GC, FPD with a phosphorus filter
VISIBLE ABSORPTIONSPECTROPHOTOMETRY
ION CHROMATOGRAPHY
ION CHROMATOGRAPHYCONDUCTIVITY DETECTION
FLOW INJECTION, FLUORESCENCEDETECTOR
ICP-AES OR AAS
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY WITHELECTROLYTIC CONDUCTIVITYDETECTOR (HALL)
INFRARED ABSORPTIONSPECTROPHOTOMETRY (IR)
HPLC; UV DETECTION
GAS CHROMATOGRAPHY, FID
VISIBLE ABSORPTIONSPECTROPHOTOMETRY
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
UV-VIS SPECTROMETER
HPLC, UV detection
INFRARED SPECTROPHOTOMETRY
GAS CHROMATOGRAPHY, SULFURSPECIFICFPD
THERMAL DESORPTION, GAS CHROMATOGRAPHY, MASS SPECTROMETRY
HPLC, UV DETECTION
LONG-PATHLENGTH PORTABLEINFRARED SPECTROPHOTOMETER
(FIELD READOUT
GAS CHROMATOGRAPHY,
GAS CHROMATOGRAPHY, NITROGENCHEMILUMINESCENCE DETECTOR
GAS CHROMATOGRAPHY, FLAMEIONIZATION DETECTOR
GAS CHROMATOGRAPHY, NITROGENSPECIFICDETECTOR
GAS CHROMATOGRAPHY, ECD
GAS CHROMATOGRAPHY, FLAMEIONIZATION DETECTOR
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
VISIBLE ABSORPTIONSPECTROPHOTOMETRY
GAS CHROMATOGRAPHY-NITROGENPHOSPHOROUS DETECTOR
ATOMIC ABSORPTION, GRAPHITEFURNACE
GAS CHROMATOGRAPHY, FIDANALYTE
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
VISIBLE ABSORPTIONSPECTROPHOTOMETRY
VISIBLE SPECTROPHOTOMETRY
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FPD
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FI
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, ATOMICEMISSION DETECTION (GC-AED)monitoring Br, C and H channels
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FI
GAS CHROMATOGRAPHY, FID
X-RAY POWDER DIFFRACTION
INDUCTIVELY COUPLED ARGONPLASMA, ATOMIC EMISSIONSPECTROSCOPY (ICP-AES)
ACID-BASE TITRATION
CHEMICAL SPOT TEST KIT (Rhodizonate-based)
ATOMIC ABSORPTIONSPECTROPHOTOMETER, FLAME
GAS CHROMATOGRAPHY, ECD
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
HPLC, ELECTROCHEMICAL ANDUV DETECTION
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY/ECD
GAS CHROMATOGRAPHY, 63Ni ECD
HPLC, UV DETECTION
ION CHROMATOGRAPHY,
CONDUCTIVITY
SPECTROPHOTOMETRY,VISIBLE ABSORPTION
SPECTROPHOTOMETRY, VISIBLEABSORPTION
HPLC, FLUORESCENCE DETECTOR/ELECTROCHEMICAL DETECTOR
HPLC, FLUORESCENCE DETECTOR/ELECTROCHEMICAL DETECTOR
HPLC, UV DETECTION
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, CAPILLARYCOLUMN, FID
ION-SPECIFIC ELECTRODE
ION CHROMATOGRAPHY,CONDUCTIVITY DETECTION
HPLC, UV DETECTION
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY
GAS CHROMOTOGRAPHY, FID
HPLC, UV DETECTION
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
SOLID SORBENT TUBES(2 coconut shell charcoal tubes,400 mg and 200 mg)
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
HPLC, UV DETECTION
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
ION CHROMATOGRAPHY, ion pairing
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY/ ELECTRONCAPTURE DETECTOR (GC/ECD)
HPLC, UV DETECTION
VISIBLE ABSORPTIONSPECTROPHOTOMETRY
ION CHROMATOGRAPHY
GAS CHROMATOGRAPHY, FID
ATOMIC ABSORPTION, GRAPHITEFURNACE
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
GAS CHROMATOGRAPHY, FID
HPLC, UV DETECTION
ATOMIC ABSORPTION, FLAME
X-RAY POWDER DIFFRACTION
X-RAY POWDER DIFFRACTION
TYPES OF CHEMICAL SOBRENT TYPES FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
HYDROCARBON HALOGENATED
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALALCOHOLS III
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALALCOHOLS COMBINED
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(Coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALACETIC ACID
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 1.0 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALCHLOROACETIC ACID
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.05 to 0.2 L/min(silica gel, 100 mg/50 mg)
MEASUREMENT TECHNIQUEION CHROMATOGRAPHY,CONDUCTIVITY DETECTION
TYPES OF CHEMICALKETONES I
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(Anasorb CMS, 150 mg/75 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALACETIC ANHYDRIDE
SAMPLING MEDIA FLOW RATELIQUID IN BUBBLER 0.2 to 1.0 L/min(mixed bubbler with 10 mL alkalinehydroxylamine)
MEASUREMENT TECHNIQUEVISIBLE ABSORPTIONSPECTROPHOTOMETRY
TYPES OF CHEMICALACETALDEHYDE by HPLC
SAMPLING MEDIA FLOW RATELIQUID IN BUBBLER(midget bubbler containing 15 mL 0.1 to 0.5 L/minGirard T solution @ pH 4.5)
MEASUREMENT TECHNIQUE
HPLC, UV
TYPES OF CHEMICALPOLYNUCLEAR AROMATIC HYDROCARBONS
SAMPLING MEDIA FLOW RATEFILTER + SORBENT TUBE(37-mm, 2-μm, PTFE + washed XAD-2, 100 2 L/minmg/50 mg)
MEASUREMENT TECHNIQUE
HPLC, FLUORESCENCE/UVDETECTION
TYPES OF CHEMICALGLYCOLS
SAMPLING MEDIA FLOW RATEXAD-7 OVS tube(glass fiber filter, 13-mm; XAD-7, 0.5 to 2 L/min200mg/100mg)
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALORGANOPHOSPHORUS PESTICIDES
SAMPLING MEDIA FLOW RATEFILTER/SOLID SORBENT TUBE (OVS-2 tube: 0.2 to 1 L/min13-mm quartz filter; XAD-2, 270 mg/140 mg
MEASUREMENT TECHNIQUEGC, FLAME PHOTOMETRIC DETE
TYPES OF CHEMICALBROMINE
SAMPLING MEDIA FLOW RATEPREFILTER + FILTER 0.3 to 1 L/min(PTFE, 0.5-μm + silver membrane,25-mm, 0.45-μm)
MEASUREMENT TECHNIQUEION CHROMATOGRAPHY,CONDUCTIVITY
TYPES OF CHEMICALAMMONIA
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE(sulfuric acid-treated silica gel) 0.1 to 0.2 L/minA 0.8-micron MCE prefilter may be used toremove particulate interferences.
MEASUREMENT TECHNIQUE
VISIBLE ABSORPTIONSPECTROPHOTOMETRY
TYPES OF CHEMICAL
1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE
SAMPLING MEDIA FLOW RATE
SOLID SORBENT TUBE 0.01 to 0.05 L/min(coconut shell charcoal, 100 mg/50 mg
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPH, FID
TYPES OF CHEMICALTRIFLUOROBROMOMETHANE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBES 0.01 to 0.05 L/min(two coconut shell charcoal tubesin series, 400 mg/200 mg and100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALTUNGSTEN (soluble and insoluble)
SAMPLING MEDIA FLOW RATEFILTER 1 to 4 L/min(0.8-μm cellulose ester membrane
MEASUREMENT TECHNIQUEATOMIC ABSORPTION, FLAME
TYPES OF CHEMICALTRICHLOROETHYLENE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALTRIBUTYL PHOSPHATE
SAMPLING MEDIA FLOW RATEFILTER (0.8-μm mixed cellulose ester 1 to 3 L/minmembrane); above 23 C, use two filtercassettes in series
MEASUREMENT TECHNIQUEGC, FPD with a phosphorus filter
TYPES OF CHEMICAL
SILICA, CRYSTALLINE,
SAMPLING MEDIA FLOW RATECYCLONE + FILTER HD cyclone: 2.2 L/min;(10-mm cyclone, nylon or Higgins- nylon cyclone: 1.7 L/minDewell (HD) + 0.8-:m MCE or 5-:mPVC)
MEASUREMENT TECHNIQUEVISIBLE ABSORPTIONSPECTROPHOTOMETRY
TYPES OF CHEMICALSULFUR DIOXIDE
SAMPLING MEDIA FLOW RATEFILTER + TREATED FILTER 0.5 to 1.5 L/min(cellulose + Na2CO3; preceded by0.8-μm cellulose ester membrane)
MEASUREMENT TECHNIQUEION CHROMATOGRAPHY
TYPES OF CHEMICALSULFURYL FLUORIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.05 to 0.1 L/min(coconut shell charcoal, 800 mg/200 mg)
MEASUREMENT TECHNIQUEION CHROMATOGRAPHYCONDUCTIVITY DETECTION
TYPES OF CHEMICALPOLYCYCLIC AROMATIC COMPOUNDS, TOTAL (PACs
SAMPLING MEDIA FLOW RATEFILTER + SOLID SORBENT 1 to 2 L/min(2-μm, 37-mm, PTFE filter + washedXAD-2 resin, 100/50 mg )
MEASUREMENT TECHNIQUEFLOW INJECTION, FLUORESCENCEDETECTOR
TYPES OF CHEMICALSUPER ABSORBENT POLYMERS
SAMPLING MEDIA FLOW RATEMEMBRANE FILTER 1 to 3 L/min(PVC, 5-μm, 37-mm)
MEASUREMENT TECHNIQUEICP-AES OR AAS
TYPES OF CHEMICALGLYCOL ETHERS
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.1 to 0.2 L/min(Anasorb® 747, 140 mg/70 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALPROPYLENE DICHLORIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE(petroleum charcoal, 100 mg/50 mg) 0.01 to 0.2 L/min
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY WITHELECTROLYTIC CONDUCTIVITYDETECTOR (HALL)
TYPES OF CHEMICALQUARTZ in coal mine dust, by IR (redeposition)
SAMPLING MEDIA FLOW RATECYCLONE + PREWEIGHED FILTER (10-mm HD cyclone: 2.2 L/mincyclone, nylon or Higgins-Dewell (HD), and nylon cyclone: 1.7 L/minPVC filter, 37-mm, 5-μm)
MEASUREMENT TECHNIQUEINFRARED ABSORPTIONSPECTROPHOTOMETRY (IR)
TYPES OF CHEMICALALIPHATIC ALDEHYDES
SAMPLING MEDIA FLOW RATECARTRIDGE (containing silica gel 0.1 to 1.5 L/mincoated with acidified 2,4-dinitrophenylhydrazine)
MEASUREMENT TECHNIQUEHPLC; UV DETECTION
TYPES OF CHEMICAL
PHENYL GLYCIDYL ETHER
SAMPLING MEDIA FLOW RATE
SOLID SORBENT TUBE 0.01 to 1 L/min(coconut shell charcoal; 100 mg/50 mg)
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALPHENYLHYDRAZINE
SAMPLING MEDIA FLOW RATEGLASS MIDGET BUBBLER 0.2 to 1 L/min(containing 15 mL 0.1 M hydrochloricacid)
MEASUREMENT TECHNIQUEVISIBLE ABSORPTIONSPECTROPHOTOMETRY
TYPES OF CHEMICAL
CRESOL (all isomers) and PHENOL
SAMPLING MEDIA FLOW RATE
SOLID SORBENT TUBE(XAD-7, 100 mg/50 mg) 0.01 to 0.1 L/min
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALPHENYL ETHER
SAMPLING MEDIA FLOW RATECHARCOAL TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALPHOSPHINE
SAMPLING MEDIA FLOW RATESORBENT TUBE 0.01 - 0.2 L/min(Hg(CN)2-coated silica gel, 300 mg/150 mg)
MEASUREMENT TECHNIQUEUV-VIS SPECTROMETER
TYPES OF CHEMICALORGANONITROGEN PESTICIDES
SAMPLING MEDIA FLOW RATEFILTER/SOLID SORBENT TUBE 0.1 to 1 L/min (OVS-2 Tube: 13-mm quartz fiber filter; XAD-2,270 mg/140 mg)
MEASUREMENT TECHNIQUEHPLC, UV detection
TYPES OF CHEMICALOIL MIST, MINERAL
SAMPLING MEDIA FLOW RATEMEMBRANE FILTER 1 to 3 L/min(37-mm diameter, 0.8-:m MCE, 5-:mPVC, 2-:m PTFE, or glass fiber)
MEASUREMENT TECHNIQUEINFRARED SPECTROPHOTOMETRY
TYPES OF CHEMICAL1-OCTANETHIOL
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(Tenax-GC, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, SULFURSPECIFICFPD
TYPES OF CHEMICAL
VOLATILE ORGANIC COMPOUNDS
SAMPLING MEDIA FLOW RATE
THERMAL DESORPTION TUBE TECHNIQUE 0.01 to 0.05 L/min(multi-bed sorbent tubes containing graphitized carbons and carbon molecularsieve sorbents
MEASUREMENT TECHNIQUE
THERMAL DESORPTION, GAS CHROMATOGRAPHY, MASS SPECTROMETRY
TYPES OF CHEMICAL
p-NITROANILINE
SAMPLING MEDIA FLOW RATE
FILTER 1 to 3 L/min(0.8 μm mixed cellulose ester membrane
MEASUREMENT TECHNIQUE
HPLC, UV DETECTION
TYPES OF CHEMICALNITROUS OXIDE
SAMPLING MEDIA FLOW RATEAMBIENT AIR OR BAG SAMPLE
MEASUREMENT TECHNIQUELONG-PATHLENGTH PORTABLEINFRARED SPECTROPHOTOMETER(FIELD READOUT
TYPES OF CHEMICALNITROSAMINES
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.2 to 2 L/min(Thermosorb/N™ air sampler
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY,
TYPES OF CHEMICAL1-NITROPYRENE IN DIESEL PARTICULATES
SAMPLING MEDIA FLOW RATEFILTER 1.0 to 2.0 L/min(Glass Fiber, 37-mm)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, NITROGENCHEMILUMINESCENCE DETECTOR
TYPES OF CHEMICAL2-NITROPROPANE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.05 L/min(Chromosorb 106, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FLAMEIONIZATION DETECTOR
TYPES OF CHEMICALNITROMETHANE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.05 L/min(Chromosorb 106, 600 mg/300 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, NITROGENSPECIFICDETECTOR
TYPES OF CHEMICALNITROGLYCERIN
SAMPLING MEDIA FLOW RATESOLID SAMPLER TUBE(Tenax-GC, 100 mg/50 mg) 0.2 to 1.0 L/min
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, ECD
TYPES OF CHEMICALNITROETHANE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBES(XAD-2, 600 mg + 300 mg) 0.01 to 0.05 L/min
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FLAMEIONIZATION DETECTOR
TYPES OF CHEMICALANILINE, o-TOLUIDINE, AND NITROBENZENE
SAMPLING MEDIA FLOW RATEFILTER + SOLID SORBENT(Glass fiber filter, sulfuric acid treated + 0.2 L/minsilica gel sorbent tube, 520/260 mg)
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALNITROAROMATIC COMPOUNDS
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.02 L/min(Silica gel, 150 mg/75 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALNITRIC OXIDE and NITROGEN DIOXIDE
SAMPLING MEDIA FLOW RATESORBENT TUBES NO: 0.025 L/min(oxidizer + 2 triethanolamine-treated NO2: 0.025 - 0.2 L/minmolecular sieve)
MEASUREMENT TECHNIQUEVISIBLE ABSORPTIONSPECTROPHOTOMETRY
TYPES OF CHEMICALNICOTINE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 1.0 L/minXAD-2 (100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY-NITROGENPHOSPHOROUS DETECTOR
TYPES OF CHEMICALNICKEL CARBONYL
SAMPLING MEDIA FLOW RATEPREFILTER + SOLID SORBENT TUBE 0.05 to 0.2 L/min(low-Ni charcoal, 120 mg/60 mg;0.8-μm cellulose ester membrane
MEASUREMENT TECHNIQUEATOMIC ABSORPTION, GRAPHITEFURNACE
TYPES OF CHEMICALNAPHTHYLAMINES, a and b
SAMPLING MEDIA FLOW RATEFILTER + SOLID SORBENT 0.2 to 0.8 L/min(glass fiber + silica gel, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FIDANALYTE
TYPES OF CHEMICALNAPHTHAS
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALMETHYL tert-BUTYL ETHER
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBES 0.1 to 0.2 L/min(two charcoal tubes in series; front 400 mg;back 200 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICAL
METHYL ETHYL KETONE PEROXIDE
SAMPLING MEDIA FLOW RATE
IMPINGER 0.5 to 2 L/min(15 mL dimethyl phthalate)
MEASUREMENT TECHNIQUE
VISIBLE ABSORPTIONSPECTROPHOTOMETRY
TYPES OF CHEMICAL
MONOMETHYLHYDRAZINE
SAMPLING MEDIA FLOW RATE
BUBBLER 0.5 to 1.5 L/min(0.1 M hydrochloric acid)
MEASUREMENT TECHNIQUE
VISIBLE SPECTROPHOTOMETRY
TYPES OF CHEMICAL
MONOMETHYLANILINE
SAMPLING MEDIA FLOW RATE
MIDGET BUBBLER 0.2 to 1.0 L/min(0.05 M sulfuric acid, 10 mL)
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALMETHYLTIN CHLORIDES
SAMPLING MEDIA FLOW RATEFILTER + SORBENT TUBE 0.25 to 1 L/min(OVS Tube: 13-mm glass fiber filter; XAD-2,270/140 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FPD
TYPES OF CHEMICALMETHYL IODIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 1 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALMETHYL ETHYL KETON
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(beaded carbon, ~150 mg/~75 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FI
TYPES OF CHEMICALMETHYL CHLORIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBES 0.01 to 0.1 L/min(two coconut shell charcoal tubes in series, 400mg/200 mg and 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALMETHYL BROMIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBES 0.01 to 0.1 L/min(two petroleum charcoal tubes, 400 mg and200 mg; drying tube, 9-g Na2SO4,necessary at humidity >50%)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, ATOMICEMISSION DETECTION (GC-AED)monitoring Br, C and H channels
TYPES OF CHEMICAL
METHYL AND ETHYL METHACRYLATE
SAMPLING MEDIA FLOW RATE
SOLID SORBENT TUBE 0.01 to 0.05 L/min(XAD-2, 400/200 mg)
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALMETHYL CELLOSOLVE ACETATE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FI
TYPES OF CHEMICALMETHANOL
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.02 to 0.2 L/min(silica gel, 100/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALLEAD SULFIDE
SAMPLING MEDIA FLOW RATECYCLONE + FILTER HD cyclone: 2.2 L/min(10-mm nylon or Higgins-Dewell (HD) cyclone nylon cyclone: 1.7 L/min
MEASUREMENT TECHNIQUEX-RAY POWDER DIFFRACTION
TYPES OF CHEMICAL
(Aqua Regia Ashing)antimony* chromium* lithium potassium tin zirconium*arsenic cobalt magnesium selenium titaniumbarium copper manganese silver tungsten*beryllium iron* molybdenum strontium vanadiumcadmium lanthanum nickel tellurium yttrium
ELEMENTS by ICP 7301
SAMPLING MEDIA FLOW RATE
FILTER 1 to 4 L/min(0.8-μm, cellulose ester membrane, or5.0-μm, polyvinyl chloride membrane
MEASUREMENT TECHNIQUE
INDUCTIVELY COUPLED ARGONPLASMA, ATOMIC EMISSIONSPECTROSCOPY (ICP-AES)
TYPES OF CHEMICALALKALINE DUSTS
SAMPLING MEDIA FLOW RATEFILTER 1 to 4 L/min(1-μm PTFE membrane)
MEASUREMENT TECHNIQUEACID-BASE TITRATION
TYPES OF CHEMICALLEAD in Air by Chemical Spot Test
SAMPLING MEDIA FLOW RATEFILTER 2 L/min(0.8-μm cellulose ester membrane)
MEASUREMENT TECHNIQUECHEMICAL SPOT TEST KIT (Rhodizonate-based)
TYPES OF CHEMICALLEAD by Flame AAS
SAMPLING MEDIA FLOW RATEFILTER 1 to 4 L/min(0.8-μm cellulose ester membrane
MEASUREMENT TECHNIQUEATOMIC ABSORPTIONSPECTROPHOTOMETER, FLAME
TYPES OF CHEMICALKEPONE
SAMPLING MEDIA FLOW RATEFILTER + IMPINGER 0.5 to 1 L/min(0.8-μm cellulose ester membrane+ impinger with 0.1 M NaOH)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, ECD
TYPES OF CHEMICALNAPHTHAS
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICAL
ISOPHORONE
SAMPLING MEDIA FLOW RATE
SOLID SORBENT TUBE 0.01 to 1 L/min(petroleum-based charcoal,
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICAL
ISOPROPYL ETHER
SAMPLING MEDIA FLOW RATE
Solid Sorbent Tube 0.01 to 0.05 L/min(coconut shell charcoal; 100 mg/50 mg)
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICAL
ISOPROPYL ACETATE
SAMPLING MEDIA FLOW RATE
SOLID SORBENT TUBE 0.02 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg,
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICAL
ISOCYANATES, MONOMERIC
SAMPLING MEDIA FLOW RATE
IMPINGER 1 L/min(solution of 1-(2-methoxyphenyl)-piperazine intoluene)
MEASUREMENT TECHNIQUE
HPLC, ELECTROCHEMICAL ANDUV DETECTION
TYPES OF CHEMICAL
ALCOHOLS II
SAMPLING MEDIA FLOW RATE
SOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALHEXACHLOROBUTADIENE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.05 to 0.2 L/min(XAD-2; 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY/ECD
TYPES OF CHEMICALHEXACHLORO-1,3-CYCLOPENTADIENE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE(2 tubes, Porapak T, 75 mg and 25 mg) 0.01 to 0.2 L/min
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, 63Ni ECD
TYPES OF CHEMICALHYDROQUINONE
SAMPLING MEDIA FLOW RATEFILTER 1 to 4 L/min(0.8-μm cellulose ester membrane
MEASUREMENT TECHNIQUEHPLC, UV DETECTION
TYPES OF CHEMICALHYDROGEN SULFIDE
SAMPLING MEDIA FLOW RATEFILTER + SOLID SORBENT TUBE 0.1 to 1.5 L/min(Zefluor, 0.5 μm; coconut shell -RECOMMENDED: 0.2 L/mcharcoal, 400 mg/200 mg
MEASUREMENT TECHNIQUEION CHROMATOGRAPHY,CONDUCTIVITY
TYPES OF CHEMICALHYDROGEN CYANIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.05 to 0.2 L/min(soda lime, 600 mg/200 mg)
MEASUREMENT TECHNIQUESPECTROPHOTOMETRY,VISIBLE ABSORPTION
TYPES OF CHEMICALHYDRAZINE
SAMPLING MEDIA FLOW RATEBUBBLER 0.2 to 1.0 L/min(15 mL 0.1 M HCl)
MEASUREMENT TECHNIQUESPECTROPHOTOMETRY, VISIBLEABSORPTION
TYPES OF CHEMICALISOCYANATES
SAMPLING MEDIA FLOW RATEIMPINGER 1 to 2 L/min(tryptamine/DMSO; 20 mL)
MEASUREMENT TECHNIQUEHPLC, FLUORESCENCE DETECTOR/ELECTROCHEMICAL DETECTOR
TYPES OF CHEMICALGLUTARALDEHYDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.05 to 0.5 L/min(silica gel coated with 2,4-dinitrophenylhydrazineHCl, 300 mg/150 mg
MEASUREMENT TECHNIQUEHPLC, UV DETECTION
TYPES OF CHEMICALFORMALDEHYDE by GC
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.10 L/min(10% (2-hydroxymethyl)piperdine onXAD-2, 120 mg/60 mg
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALPOLYNUCLEAR AROMATIC HYDROCARBONS
SAMPLING MEDIA FLOW RATEFILTER + SORBENT 2 L/min(2-μm, 37-mm PTFE + washed XAD-2,100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, CAPILLARYCOLUMN, FID
TYPES OF CHEMICALFLUORIDES, aerosol and gas
SAMPLING MEDIA FLOW RATEFILTER + TREATED PAD(0.8-μm cellulose ester membrane + 1 to 2 L/minNa2CO3-treated cellulose pad)
MEASUREMENT TECHNIQUE
ION-SPECIFIC ELECTRODE
TYPES OF CHEMICALFORMIC ACID
SAMPLING MEDIA FLOW RATEFILTER + SOLID SORBENT TUBE 0.05 to 0.2 L/min(PTFE membrane, 5-μm + washed, silicagel, 400 mg/200 mg)
MEASUREMENT TECHNIQUEION CHROMATOGRAPHY,CONDUCTIVITY DETECTION
TYPES OF CHEMICALFORMALDEHYDE
SAMPLING MEDIA FLOW RATECARTRIDGE 0.03 to 1.5 L/min(Cartridge containing silica gel coated with2,4-dinitrophenylhydrazine)
MEASUREMENT TECHNIQUEHPLC, UV DETECTION
TYPES OF CHEMICALPROPYLENE OXIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALETHYL BROMIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALMERCAPTANS, METHYL-, ETHYL-, and n-BUTYL
SAMPLING MEDIA FLOW RATEFILTER 0.1 to 0.2 L/min(glass fiber, 37-mm, impregnated withmercuric acetate)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY
TYPES OF CHEMICALETHYL ETHER
SAMPLING MEDIA FLOW RATESolid Sorbent Tube 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMOTOGRAPHY, FID
TYPES OF CHEMICALETHYLENIMINE
SAMPLING MEDIA FLOW RATEBUBBLER 0.2 L/min(Folin's reagent
MEASUREMENT TECHNIQUEHPLC, UV DETECTION
TYPES OF CHEMICALESTERS 1
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALETHYLENE CHLOROHYDRIN
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(petroleum charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALHYDROCARBONS, AROMATIC
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALETHYL CHLORIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBES(2 coconut shell charcoal tubes, 0.02 to 0.05 L/min400 mg and 200 mg)
MEASUREMENT TECHNIQUE
SOLID SORBENT TUBES(2 coconut shell charcoal tubes,400 mg and 200 mg)
TYPES OF CHEMICALETHYL ACETATE
SAMPLING MEDIA FLOW RATE
SOLID SORBENT TUBE 0.01 to 0.2 L/minute(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUE
GAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALALCOHOLS IV
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.05 L/min(Coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALAMINOETHANOL COMPOUNDS I
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(silica gel, 300 mg/150 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALDYES, BENZIDINE-, o-TOLIDINE-, o-DIANISIDINE
SAMPLING MEDIA FLOW RATEFILTER 1 to 3 L/min(5-μm PTFE membrane
MEASUREMENT TECHNIQUEHPLC, UV DETECTION
TYPES OF CHEMICALDICHLOROFLUOROMETHANE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBES 0.01 to 0.05 L/min(2 coconut shell charcoal tubes,400 mg and 200 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALAMINES, ALIPHATIC
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 1.0 L/min(silica gel, 150 mg / 75 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALAMINOETHANOL COMPOUNDS II
SAMPLING MEDIA FLOW RATEIMPINGER 0.5 to 1 L/min(15 mL 2 mM hexanesulfonic acid)
MEASUREMENT TECHNIQUEION CHROMATOGRAPHY, ion pairing
TYPES OF CHEMICALMETHYLENE CHLORIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT 0.01 to 0.2 L/min(2 coconut shell charcoal tubes, 100/50 mg
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALDIAZOMETHANE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.2 L/min(octanoic acid-coated XAD-2 resin,100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALCHLORINATED AND ORGANONITROGEN HERBICIDES
SAMPLING MEDIA FLOW RATEFILTER/SOLID SORBENT TUBE 0.2 to 1 L/min(OVS tube: 11-mm quartz filter; XAD-2)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY/ ELECTRONCAPTURE DETECTOR (GC/ECD)
TYPES OF CHEMICAL2,4-D
SAMPLING MEDIA FLOW RATEFILTER 1 to 3 L/min(glass fiber, binderless
MEASUREMENT TECHNIQUEHPLC, UV DETECTION
TYPES OF CHEMICALCHROMIUM, HEXAVALENT
SAMPLING MEDIA FLOW RATEFILTER 1 to 4 L/min(5.0-μm PVC membrane)
MEASUREMENT TECHNIQUEVISIBLE ABSORPTIONSPECTROPHOTOMETRY
TYPES OF CHEMICALACIDS, INORGANIC
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.2 to 0.5 L/min(washed silica gel, 400 mg/200 mg withglass fiber filter plug)
MEASUREMENT TECHNIQUEION CHROMATOGRAPHY
TYPES OF CHEMICALACETONITRILE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE(coconut shell charcoal, 400/200 mg) 0.01 to 0.2 L/min
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICAL
ARSENIC TRIOXIDE
SAMPLING MEDIA FLOW RATE
FILTER 1 to 3 L/mi(Na2CO3-impregnated, 0.8-μm celluloseester membrane + backup pad)
MEASUREMENT TECHNIQUE
ATOMIC ABSORPTION, GRAPHITEFURNACE
TYPES OF CHEMICALVANADIUM OXIDES
SAMPLING MEDIA FLOW RATECYCLONE + FILTER HD cyclone: 2.2 L/min(10-mm cyclone or Higgins-Dewell (HD) + nylon cyclone: 1.7 L/min5-μm PVC membrane)
MEASUREMENT TECHNIQUEX-RAY POWDER DIFFRACTION
TYPES OF CHEMICALZINC OXIDE
SAMPLING MEDIA FLOW RATEFILTER 1 to 3 L/min(0.8-μm PVC membrane, 25-mm diameter, inopen-face cassette)
MEASUREMENT TECHNIQUEX-RAY POWDER DIFFRACTION
TYPES OF CHEMICALZINC and compounds, as Zn
SAMPLING MEDIA FLOW RATEFILTER 1 to 3 L/min(0.8-μm cellulose ester membrane
MEASUREMENT TECHNIQUEATOMIC ABSORPTION, FLAME
TYPES OF CHEMICALWARFARIN
SAMPLING MEDIA FLOW RATEFILTER 1 to 4 L/min(1-μm PTFE membrane)
MEASUREMENT TECHNIQUEHPLC, UV DETECTION
TYPES OF CHEMICALAMINES, AROMATIC
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE(silica gel, 150 mg/75 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALVINYL ACETATE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.1 to 0.2 L/min(carbon molecular sieve; 160 mg/80 mg;ORBO-92 or equivalent)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALVINYLIDENE CHLORIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 100 mg/50 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALVINYL BROMIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.01 to 0.2 L/min(coconut shell charcoal, 400 mg/200 mg)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID
TYPES OF CHEMICALVINYL CHLORIDE
SAMPLING MEDIA FLOW RATESOLID SORBENT TUBE 0.05 L/min(2 tandem tubes, each with 150 mg activatedcoconut charcoal)
MEASUREMENT TECHNIQUEGAS CHROMATOGRAPHY, FID