air purifier - freshairpro.com ap-1506dh owner's … · air purifier ap-1506dh ... manual...
TRANSCRIPT
0000000
AP-1506DHAir Purifier
The Letter of Guarantee is enclosed here with this Coway productrealizing "Quality is the best policy".
Air Purifier
Air Purifier
2
3
4
5
02
There are four different types (for yellow dust, forbabies, for new house owner and for old houseowner) of Customized filters, each designed for youruse according to needs.
It is an artificial intelligence function which uses alearning algorithm. It is designed to provide a pleasantindoor environment with speed adjustment of an airpurifier to prevent the occurrence of same type ofpollution by analyzing changing patterns in the userenvironment.
It is designed for speedy disposal of the pollutantsby applying the appropriate auto-swing system forindoors air circulation.
Dust and odor sensors lead to improved sensorfunction for indoor pollution.
Customized Filter
Artificial intelligence
Auto-swing system
Dual sensor
03
COWAY
FEATURES
The device uses HEPA filter (treated with organic anti-bacterial microorganisms) with excellent anti-bacterialand mold function to remove drifting fine dust andbacteria. Filter system is designed to removepollutants instantly.
Excellent air cleaning1
>> Coway Air Purifier(AP-1506DH) has differentiated functions
DEAR CUSTOMERS
‐Electricity Safety‐Installation Safety
‐Operation Safety
For information
Safety Information 04040709
Names of Each Part 11
Air Purified Process 13
How to use
Please Keep in Mind 15
Preparations 17
20
First of all, we would like to thank you very much for purchasing thisCoway air purifier. This product is superior to the ones in the past infunction and we believe that it will provide you with cleaner andhealthier air. We would like to recommend you to read this User'sManual carefully for proper operation and maintenance and keep thismanual well together with the warranty. This user's manual couldsolve your problem resulted from that you can easily fix yourself injust a few minutes.
Contents
Operation Part/Indication Part
22How to use
1719
‐Filter Installation‐Remote Control
Installation and cleaning
‐Product Filter
Cleaning Method 2525
Filter Replacement Method 27
Others
Before Asking A/S 29
Specification 30Warranty Information 31
※ Please keep the manual near your sight and in the reach of your hand.
Features
24Adjust Particle Sensor
04 05
Fo
rIn
form
ation
SAFETY INFORMATION
Electricity Safety
Connect it to voltage rating thatmatches it on the rating plate.Electrical shock or fire may occur as a result.
Do not use if the cord appearsto be damaged. Please askCustomer Service to replacethe cord.Electrical shock or fire may occur asa result.
05
Unplug the unit before repair,inspection, or replacement.Electrical shock may occur as a result.
Do not use if the cord appears tobe damaged. Please ask Customer Service to replace the cord.Electrical shock or fire may occur as a result.
If the cord or plug is wet, unplugthe unit and let it completely drybefore subsequent use.Electrical shock or fire may occuras a result.
Do not unplug by pulling thecord or handle the plug with wethands.Electrical shock or fire may occuras a result.
Do not attempt to repair thepower cord.Electrical shock or fire may occur as a result.
Do not repeatedly plug and unplug the unit from the electrical outlet. Electrical shock or fire may occur as a result.
Safety
Information
Electricity
Safety
-
Be careful to keep this safety information. Please read this information to prevent property loss and ensure your safety.
If not observed, seriousinjury or even deathcould occur.Danger
If not observed, seriousinjury or property damagecould occur.Warning
If not observed, slightinjury or property damagecould occur.
Caution
06 05
Fo
rIn
form
ation
07
SAFETY INFORMATION
Danger Warning Caution
Safety
Information
Electricity
Safety
InstallationS
afety
-
-
Installation Safety
Do not install unit in damp ormoist areas.Electrical shock or malfunctioningmay occur as a result.
Do not install close to heatingunits.Fire may occur as a result.
Do not place containers holdingwater, medicines, small metallicobjects or inflammatory materialson top of the unit.Electrical shock, fire or malfunctioningmay occur as a result.
Install the unit in a location wherethere are no obstacles in itssurrounding making it ideal for aircirculation.
Do not run the power cord under a heavy object to prevent it from being damaged.Electrical shock or fire may occur as a result.
Do not plug into an outlet orpower strip that is being usedby several other appliances.Use a separate outlet for the unit.Fire may occur as a result.
Remove any dust or water if it’s on the plug.*Never use Benzene or gasolineto clean the plug.Electrical shock or fire may occur as a result.
Do not carry the unit by its power cord.Electrical shock or fire mayoccur as a result.
unplug the power cord whennot using for a long time.Electrical shock or fire may occuras a result.
Unplug the power cord whencleaning the product.Electrical shock or fire mayoccur as a result.
Do not install on a level area norapply force to the unit.Breakage or malfunctioning mayoccur as a result.
Please read this information to prevent property loss and ensure your safety.
Electricity Safety
08 05
Fo
rIn
form
ation
09
SAFETY INFORMATION
Safety
Information
InstallationS
afetyO
perationS
afety
-
-
Place the unit 20cms away fromthe wall and surrounding objectsand 30~60cms away from theceiling.An object close to the wall or ceilingcould be contaminated.
Keep the device away fromlighting devices or direct sunlight.Operations using remote controlmay not become possible.
Do not use the unit in places suchas restaurants where there areheavy smoke, odor or oil.It may become cause of a slowerperformance.
Install the unit at least 2m awayfrom electrical appliancesincluding TV.Radio interference may occur.
Do not place the unit on electricalappliances such as heater orhome appliances.It could cause electric shock, fire ormalfunctioning of the electricalappliances.
Do not use under direct sunlight.It could cause fading or decolorizing.
Operation Safety
Do not use or keep flammablegas or materials near the product. There is risk of fire.
Do not insert finger or foreignobjects into the intake area oroutlet, and do not thrust unit withsharp objects.There are risks of injury andmalfunctioning.
Do not spray any inflammablematerials including insecticidesor aromatics near the product.It could cause fire or malfunctioning.
Upon detecting strange sound,odd smell or smoke, immediatelyunplug the product and call thecustomer service center. There is risk of fire.
Do not allow people to climbonto the unit.There is risk of injury.
Be careful not to let parts of thebody or objects get caught onthe upper part of the productwhen opening the front cover.There is risk of injury.
Please read this information to prevent property loss and ensure your safety.Danger Warning Caution
Installation Safety
10
Please read this information to prevent property loss and ensure your safety.
11
Fo
rIn
form
ation
SAFETY INFORMATION NAMES OF EACH PART
Never soak the unit in water.It could cause electric shock orproduct deterioration.
Do not disassemble, repair ormodify the unit with one’sdiscretion.There are risks of electric shock orproduct damage.
Change to new filter within givenperiod.It could cause product deterioration.
Do not operate the unit in areaswhere there is oil mist.It could cause fire or productdeterioration.
User Pre filter only after regularcleaning with water and fullydrying.
Keep away from the outlet.If you operate the outlet in your ownway, it could affect the function ofproduct.
Customized, HEPA and Deodorantfilters will not be restored even afterwashing with water. Never soak orwas with water.
※ When the outlet doesn’t return toits normal angle(85�), switch offpower and on again.
Safety
Information
Operation
Safety
Nam
esofE
achP
art
-
Front
Display Panel▶
Control Panel▶
Inlet▶
Odor Sensor▶
Remote ControlReceiving Part
▶
Front Cover▶
/
Operation Safety
12 13
Fo
rIn
form
ation
NAMES OF EACH PART AIR PURIFIED PROCESS
Pre Filter▶
Pre Non-wovenfabric Filter
▶
Customized Filter▶
HEPA Filter▶
Deodorant Filter▶
Rear
Remote Control
Power cord ▶
VentilationGrille
▶
Particle Sensor ▶
Remote Control Holding Slot
▶
Handle ▶
Mode▶
Circulation▶
Speed▶
Power▶
Nam
esofE
achP
artA
irP
urifiedP
rocess
/
14 15
Ho
wto
Use
Pre FilterThe anti-bacterial Pre filter aids in sterilization and collects pet hair,large size allergens and dust.
Pre Non-woven fabric FilterIt removes dust and hairs in front of the Customized filter and protects Customized filter and HEPA filter.
Customized FilterThere are 4 filters(used for yellow dust-free, babies, new house owner, old houseowner), which you may choose based on needs.The filter for yellow dust-free(Brown) efficiently reduces Yellow dusts including Sox.(Test result 1)The filter for babies(Orange) is helpful for the baby’s health, which reduces influenzaviruses such as H5N1, H3N1. (Test result 2)The filter for new house owner(Black) effectively reduces Formaldehyde andtoluene(VOC). (Test result 3)The filter for old house owner(Yellow) efficiently reduces legionella viruses that can beeasily found in old houses. (Test result 4)
※ Authorization and test institutions1) Busan Techno-park (Authorized institution)2) Veterinary Research Institute in China, Tottori University, Tsukuba University3) Mitsubishi Paper Mills4) Ecosphere Research Institute at Kyoto University
▶Air Purified System
HEPA FilterThe high-function HEPA filter significantly removes fine particles and cigarettesmoke while the anti-bacteria and anti-mold nano-silver and catechin eliminategerms and mold.
Deodorant FilterThe activated carbon filter, efficiently eliminates food odors and unpleasant smells.
AIR PURIFIED PROCESS
▶Key points for proper use of air purifiers!
Filter should be installed in order touse the product. (See P.17)※ Filter is delivered in packaged. Remove
filter wrapping first.
1 Install filter.
Power needs to be connected inorder for the air purifier to operateproperly. (See P.17)
2 Connect power.
Press the power button and select fan speed. (See P.22)
3 Select speed button for manual operations.
�
Air
Purified
Process
Please
Keep
InM
ind
PLEASE KEEP IN MIND
/
16 17
Ho
wto
Use
Please
Keep
InM
indP
reparations
PLEASE KEEP IN MIND
Press the power button and selectauto mode. (See P.22)
4 Press mode select button forauto running.
Product and filter must be cleaned atregular intervals for smooth operationof the product and maintaining itsperformance. (See P.25)
5 Clean the product and filterat regular intervals.
6 Change filters within given period.Filter should be changed within given periods in order tomaintain optimal performance of the product. (See P.27)
�
▶ Must check before use!
Connect it to voltage rating that matches it on the rating plate.
How to install filter
■ Always remove filter wrapping before installation.■ The unit is for residential use and thus for indoor only.■ Remove power plug from the socket when not in use.■ Check front part of the filter when installing unit.
�
Pull out lower part of the front coverand open up by pushing it upwards.
Open front cover.1
Take out the filter by pulling out the filter casehandle forward and remove filter wrapping.
2
PREPARATIONS
Pre filter→Pre Non-woven fabric Filter→Customized filter→HEPA filter→Deodorant filter
▶ Order of filters
/
▶Key points for proper use of air purifiers!
18 19
Ho
wto
Use
Preparations
Inserting filter
Mount on the unit in the order ofDeodorant, HEPA, Customized, PreNon-woven fabric filter and Pre filters.(Check direction and order of insertingfilters and make sure hooks on bothsides of the filters are well adjusted.)
3
� Deodorant Filter � HEPA Filter � Customized Filter
� Pre Non-wovenfabric Filter
� Pre-Filter
� �
� �
Pre Non-woven fabric filter on the front part should beattached to the front part of Customized filters.Refer to page 28 “How to Exchange Filters” to attach it.
●
※ On shipment, the Pre Non-woven fabric filter on the front part isattached to Customized filters.
PREPARATIONS
▶ Must check before use!
Preparing remote control and how to use
- If the remote control doesn’t work, check batteries lifespan.- If necessary, switch batteries of CR2025.- If you don’t use the remote control for a long time, be careful to pull out the
battery from it.- The lifespan of remote control depends on the usage frequency.
▶ While using the remote control
- If you use the remote control, place it toward the receiving part of a product.- The obstacles between the product and remote may prevent the remote
control from working. - Do not apply force to the remote control.- Do not place the remote control in a wet place or under the direct sunlight or
near heaters.
▶ How to use remote control.
Push batteries container hook on thebottom at the back side of the remotecontrol in � direction and at the sametime pull out the batteries container in� direction.
1
Insert enclosed batteries in itsappropriate positions at the containeraccording to it’s + positions at thehook.※ Make sure + directions of the batteries
are checked.
※ Use the same procedure above when switching batteries.
2
Thrust in batteries container withbatteries into the remote control inletuntil you hear the clicking sound.
3
20 21
Ho
wto
Use
OPERATION PART/INDICATION PART
▶ Operation Part
Select mode
Speed
Power
Circulation/Anion
▶
▶▶
▶
1 3
42
Sensor to detect the levelof brightness in thesurroundings.
Illumination sensor●●
To be used when changingspeed. Use speed button toselect 5 different speed modesfrom level 1→2→3→4→turbo.
Speed3
Use to turn the power on and off.※ Press the “power” button for
2~3 seconds in order topower off.
Power4
Sensor to detect the levelof odor pollution.
Odor sensor
Use to switch operationsmode. Operations mode can beselected by pressing themode selection button whichwill move in the order of auto→artificial intelligence→turbomodes. Display light in the selectedoperations mode will light upwhenever the button ispressed.※ Pressing speed button
during mode operationswill immediately switch tomanual mode.
Select mode 2Use to select swing circulationmode or anion mode. If swingcirculation is in operation,circulation icon in the displaypart will light up and the swinggrill will start rotating. If anionmode is in operation, anion iconin the display part will light up.
Circulation/Anion1
Operation
Part/Indication
Part
▶ Indication Part
Artificial intelligence mode
Air pollution level
Anion mode Sleep modeSpeed
Auto mode Swing circulation mode
▶ ▶ ▶ ▶
▶ ▶
2 64
5 731
Speed is automatically controlledand displayed according to levelof indoor pollution under automode. And under manual mode,it will be displayed according tospeed button selection as perlevels 1→2→3→4→turbo.
Speed1
It is displayed upon selectionof the artificial intelligencemode, which is designed toefficiently remove indoorpollutants.
Artificial intelligence mode3
It displays the discharge ofanion together with purified air.
Anion mode5
It displays the air purifierbeing run in silent modeduring sleep.
Sleep mode7
It indicates auto modestatus and it is runautomatically accordingto level of pollution.
Auto mode 2
Upon selection of theswing circulation mode,it displays the swing grillin rotation mode.
Swing circulation mode4
It displays the level ofdust and odor pollution,and it is displayed in 4levels according to itspollution level.
Air pollution level6
▶
22 23
Ho
wto
Use
HOW TO USE
Press the power button to turn on and select fan speed by selectingthe speed button.
�
Level 1→2→3→4→Turbo※ Pressing fan speed button even during mode operations (auto/ artificial
intelligence/ turbo) will immediately switch to manual operations mode.
Press the power button to turn on and select operations mode bypressing the mode select button.
■ Don't forget to plug power before operating the unit.■ Unit will automatically start running with auto mode.
▶ To select manual mode
▶ To select auto operations mode
Fan speed will be adjustedautomatically (from levels 1~4)for optimal operations dependingon the level of indoors pollutiondetected by the dust and odorsensors.
Will store level of indoors pollutiondetected by the dust and odor sensorsand self-adjust operations condition beforerepeated pollution by analyzing user'sindoors environment change pattern.
Auto Mode Artificial Intelligence(Learning) Mode
※ When switching from auto/artificial intelligence/turbo to manual operations mode, the manual operationsmode will start from level 1 (regular speed).
Enables speedy cleaning ofindoors air by adjusting fanspeed a level faster than thelevel of indoors pol lut iondetected by the dust and odorsensors.
Turbo Mode
Artificial intelligence (learning) mode�When the level of pollution continues at 1, operations will be repeatedly suspended for as long as 10~30 minutes.�Operations mode will be switched when current level of pollution is higher than the level stored.
How
toU
se
Auto→artificial intelligence→turbo
Select swing mode by pressing the power button and select swingmode by pressing the button.※ Operations can be confirmed on the swing mode light at the display panel.
▶ To run swing mode
When the unit's surrounding gets dimmer for more than 3 minutes whilerunning in auto/ artificial intelligence/ turbo mode, the unit willautomatically run in low wind, noise and electricity consumption mode.When the surrounding becomes bright again, normal operations willresume.�Sleep mode operations under the artificialintelligence mode will repeat the cycle of 10minutes operation and 30 minutessuspension of work.(Selection of different mode buttons ispossible with sleep mode operations underthe artificial intelligence mode but in stopcondition, only the power button can beused.)
▶ To run sleep mode
�
24 25
Installationand
Cleaning
AdjustP
articleS
ensorC
leaningM
ethod
▶ To adjust particle sensors
Upon product shipment, particle sensors are adjusted to normal level. When the level of pollution remainsat its height even after running the air purifier for more than 2 hours in highly polluted conditions or when itmaintains lowest level for more than an hour even in highly polluted conditions, use the following methodsto adjust the sensor before use.
CLEANING METHOD
Select desired sensor level and press selectspeed/mode buttons at the same time for 2~3seconds. The display panel will then resumenormal operations and sensor level will bedisplayed accordingly.
Press both select speed/mode buttons at thesame time for 2~3 seconds while the unit is inoperations.
‘Dust pollution' display will start to flicker anddisplay that it's adjusting sensors.
Press speed select button and adjust to desiredsensor mode. Sensor level will be displayed onthe dust pollutiondisplay panel.
1
2
3
4
※ When no buttons are selected for 10 seconds, thecorresponding value will automatically be given.
ADJUST PARTICLE SENSOR
�Level 1: Sensitive�Levels 2~3: Average�Level 4: Insensitive
�
■ Always unplug power first prior to cleaning.■ Do not use detergents including organic solvents, bleach, chlorine or abrasives.■ Do not soak unit or sprinkle in water.
�
▶ Cleaning air intake and outlet (Cleaned every 2 months)
▶ Cleaning particle sensor (Cleaned every 2 months)
Open the particle sensor cover located on the right sideof the unit. Use a wet cotton swab to clean the lens,dust inlet and outlet and wipe again using dry cottonswab to remove moisture.
■
Clean air intake and outlet with soft brush or a vacuum cleaner.■
▶ Cleaning the unit (Cleaned every 2~4 weeks)
Use soft dry cloth to clean the unit.■
※ Take caution not to letdust fall to the inner partof the unit.
Wipe with slightly moist cloth for more serious stains(do not use abrasives).
※ Failure to clean regularly willresult in mal functioning ofthe particle sensor.
※ Clean more often inenvironments with moredust.
Outlet
Intake
dust outlet
dust inlet
/
26 27
Installationand
Cleaning
CLEANING METHOD
▶ Cleaning pre filter (Cleaned every 2~4 weeks)
■ Always unplug prior to cleaning filter.■ Pre filters may be restored by removing dust or washing with water.■ Failing to clean pre filters for a long time may cause mal functioning of
the unit.■ Customized, HEPA and Deodorant filters will not be restored. Never
wash with water.
When the moisture is completely dry, pushelectrostatic filter back to the case andcomplete its installation. Front cover should be put back to the product.
Softly pull out bottom of the front cover toremove it from the unit.
Pull out the filter handle to release it.
Use vacuum cleaner or water toremove dust from the filter.
1
2
3
4
※ Filter case should be thrustin accurately into the filtercase ring of the unit.
�
※ Carefully release filter to prevent dustfrom falling apart.
▶ How to change
Always unplug the unit before changing filters.■
Always check on 'front part' in assembling filters.■
Change filters by referring to installation methodon page 17.
■
Always use genuine Coway filters in order to maintain theunit's optimal performance.
■
▶ Filter clean and changing cycle
※ It is based on 24 hours per day in an automatic operation. ※ The above replacement of filter is only recommendation. It depends on user's conditions.
Clean or washPre Filter
ReplacementHEPA Filter
Pre Non-woven Fabric Filter Replacement
Customized Filter Replacement
Deodorant Filter
Every 2~4 weeks
Every 12 months
Every 2 months
Every 6 months
Every 12 months Replacement
Filterfor residential use
Clean/change cycle
Every 2~4 weeks
Every 12 months
Every 1 month
Every 4 months
Every 12 months
for business useClean/change
FILTER REPLACEMENT METHOD
Cleaning
Methodr
Filter
Replacem
entMethod
/
28 29
OtherC
autionsforS
afety
FILTER REPLACEMENT METHOD
▶How to replace the filters
Check front part of Customized and HEPAfilters before changing filters.
When exchanging non-woven fabric, removeit from the side part of the Customized filterand attach new non-woven fabric to thefilter.
1
2
▶Check the followings before asking A/S.Air purifier may be running abnormally for reasons other than product defect which includemishandling of the product or other miscellaneous reasons. In such cases, do check onthe below cases to get simple help even without calling for A/S. When problem stillremains even after checking through the list, please call customer service.
A/S Phone No : 213-480-1600
There is no aircoming out
Problem Check Items Solutions
� Is the display panel switched off?
� Is there a blackout?
� Is the unit plugged in?
Operate the unit after electricityhas been restored.
� Has the filter wrapping beenremoved?
First remove the filterwrapping.
Press the power button andselect desired function.
Connect the power to thevoltage rating that matchesit on the rating plate.
� Is the sleep mode lamp on? During sleep mode, it willbe fixed to minimal speed.
� Has the dust detection sensor beencleaned?
When much dust accumulatesin the dust detection sensor,the sensor won't be able todetect pollution properly thus itneeds regular cleaning.
� Isn't it over filter cleaning or switchperiod?
Check filter clean/ switch periodand follow necessary procedure.
� Please check batteries lifespan. Switch batteries.
� Are the batteries properly installed? Install batteries in properdirections.
� Are the lights inside the roomflickering?
Switch lamps or relocate unit.
� Is the unit close to electricalappliances?
Keep the unit at least 2m awayfrom electrical appliances.
Speed doesn'tchange in auto/artificialintelligence/turbomode.
Speed hasbecomeremarkably slow.There is bad odorfrom the diffuser.
Remote controlis not working.
BEFORE ASKING A/S
Filter
Replacem
entMethod
Before
Asking
A/S
/
30 31
SPECIFICATION
OtherC
autionsforS
afety
※Without prior notice the unit could be changed to improve its performance.
Product
Model
Coway Air Purifier
AP-1506DH
Power Supply Voltage rating that matches it on the rating plate.
Phase 1
Rated Current 51W
Dust Collection Method HEPA Filter Type
Room Area 51㎡
Maximum Volume of Air 7.3㎥/min
Size 530(W) X 300(D) X 685(H)mm
Weight 12.8kg
WARRANTY INFORMATION
Product Guarantee
Parts and components shall be replaced free of charge within the guarantee period ifthe defects occur due to manufacturing defects in normal operation.Contact us in case of breakdown.In the following cases, repair work shall be charged even within the guarantee period.▶Breakdown caused by careless operation or unreasonable repair and renovation.▶Breakdown caused by nonperformance of the instructions specified in the manual.
Even after the expiration of guarantee period, it is possible to apply for charged repair.Present this Letter of Guarantee whenever repair is needed.This Letter of Guarantee is valid only in domestic where you buy this product.Keep this Guarantee carefully as it is not re-issued.
Please contact our customer's service center in case you are not satisfied with our A/S service.
● Nationwide Periodical Inspection and Filter Replacement Call : 213-480-1600
● Nationwide A/S Call : 213-480-1600
● Customer Counseling Center Call : 213-480-1600 Fax :
In case any other filters or parts which are not genuineproducts of we are used, we is not responsible for anyproblems related to water quality.
☞
Model AP-1506DH
1 year
Guarantee Period
Serial No.
Date of Purchase
Guarantee Period From To
Customer’s Address
Customer’s Name Tel.
Coway Co., Ltd658 Yugu-Ri, Yugu-Eub, Gongju-Si, Choongchungnam-Do, Korea
Tel : 82-41-850-7879 Fax : 82-41-841-7816www.coway.com
1.
2.3.
4.5.6.7.
Specification
Warranty
Information
-