air monitoring report€¦ · nova consulting group, inc. (nova) provided on-site air monitoring...

34
AIR MONITORING REPORT 2nd & 3rd Floor Hallways Murray Junior High School 2200 Buford Ave. St. Paul, MN 55108 August 8 – 14, 2006 Nova Client No.: STPAU006/Project No: H06-0946

Upload: others

Post on 13-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

AIR MONITORINGREPORT

2nd & 3rd Floor HallwaysMurray Junior High School2200 Buford Ave.St. Paul, MN 55108

August 8 – 14, 2006

Nova Client No.: STPAU006/Project No: H06-0946

Page 2: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

AIR MONITORING REPORT

2nd & 3rd Floor HallwaysMurray Junior High School

2200 Buford Ave.St. Paul, MN 55108

Nova Client No.: STPAU006Project No.: H06-0946

August 8 – 14, 2006

Prepared For:

Saint Paul School District360 Colborne Street

Saint Paul, MN 55102

Prepared By:

Brian Meyer, Project ManagerJason Karpe, Air Monitoring Specialist

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400

Chaska, MN 55318

Page 3: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Murray Junior High School, St. Paul, MN H06-0946R.001-BJMPage i August 8 – 14, 2006

TABLE OF CONTENTS

Section Page

1.0 INTRODUCTION ....................................................................................................................1

2.0 ENCLOSURE SUMMARY .....................................................................................................2

3.0 AIR MONITORING AND SAMPLE ANALYSIS..................................................................3

4.0 WASTE TRACKING ...............................................................................................................4

APPENDICES

A: Air Sample Results SummaryB: Air Sample Results DetailC: Sample Location MapsD: Daily Log ReportsE: Personnel Certification FormF: Waste TrackingG: Daily Microscope ChecklistH: Personnel Certifications

Page 4: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Murray Junior High School, St. Paul, MN H06-0946R.001-BJMPage 1 August 8 – 14, 2006

1.0 INTRODUCTION

Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal ofasbestos-containing materials located in the 2nd & 3rd Floor Hallways at the Murray Junior HighSchool building, 2200 Buford Ave., St. Paul, MN 55108.

Removal was conducted using floor tile enclosure and full enclosure asbestos abatementtechniques. All asbestos-related work was performed in accordance with Federal, State, andLocal asbestos regulations.

Asbestos-related work began on August 8, 2006 and was completed on August 14, 2006. TwellEnviornmental, License #592, conducted the asbestos abatement.

Sample collection and analysis was completed by Jason Karpe of Nova Consulting Group, Inc.,1107 Hazeltine Boulevard, Suite #400, Chaska, MN 55318.

Page 5: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Murray Junior High School, St. Paul, MN H06-0946R.001-BJMPage 2 August 8 – 14, 2006

2.0 ENCLOSURE SUMMARY

The following enclosure summary describes each enclosure including location of the enclosure andmaterials removed. Also identified is the clearance date and whether destructive means were usedto access ACM located in interstitial spaces or other inaccessible areas.

Specific details relating to enclosure construction and removal details can be found in the daily logslocated in the appendices.

Enclosure Number: 1Enclosure Type: Floor Tile EnclosureArea: 1200 SFLocation: Third FloorRoom Number: HallwayClearance Date: 8/10/2006Destructive Means Used: NoMaterial Identification Subcategory Description Quantity Unit9x9 Floor Tile & Mastic Tan With Brown Streaks 1200 SF

Enclosure Number: 2Enclosure Type: Full EnclosureArea: 1200 SFLocation: Second FloorRoom Number: HallwayClearance Date: 8/11/2006Destructive Means Used: NoMaterial Identification Subcategory Description Quantity Unit9x9 Floor Tile & Mastic Tan With Brown Streaks 1200 SF

Page 6: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Murray Junior High School, St. Paul, MN H06-0946R.001-BJMPage 3 August 8 – 14, 2006

3.0 AIR MONITORING AND SAMPLE ANALYSIS

On-site air monitoring was provided by Jason Karpe. PCM sample collection and analysis wascompleted in accordance with NIOSH Method 7400. Quality control procedures were followedas required by this method. Air sample analysis results can be found on the air sample summarytable located in the appendices.

Page 7: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Murray Junior High School, St. Paul, MN H06-0946R.001-BJMPage 4 August 8 – 14, 2006

4.0 WASTE TRACKING

All asbestos waste containers were labeled with the required EPA, DOT, and OSHA labels. Thefollowing waste containers were removed from the project site:

Date Qty Waste Container Type ofTransport

ImmediateDestination

8/10/2006 14.0 Fiber Drums Truck Dumpster8/10/2006 10.0 6-Mil Poly Bag Truck Dumpster8/11/2006 16.0 Fiber Drums Truck Dumpster8/11/2006 14.0 6-Mil Poly Bag Truck Dumpster

Waste was transported to the SKB Rosemont Industrial Waste Facility located at 13425Courthouse Blvd., Rosemount, MN 55068.

A waste tracking table is located in the appendices.

Page 8: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

APPENDIX A

AIR SAMPLE RESULTS SUMMARY

Page 9: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Air Sample Results by Enclosure

Building NumberBuilding Name Murray Junior High School

Project Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District Building Address: 2200 Buford Ave.

St. Paul MN. 55108

AreaLocationRoom Number

Enclosure NumberEnclosure Type

DateCollected

Sample NumberSample Location

Type ofSample

Sub-Typeof Sample

Result

1200 SFThird FloorHallway

8/9/2006003-0001 Negative Pressure Enclosure

AdjacentFloor Tile Enclosure

Enclosure # 1 <0.01Outside Of Decontamination

1200 SFThird FloorHallway

8/9/2006003-0002 Negative Pressure Enclosure

AdjacentFloor Tile Enclosure

Enclosure # 1 <0.01Outside Of Decontamination

1200 SFThird FloorHallway

8/10/2006003-0003 Negative Pressure Enclosure

AdjacentFloor Tile Enclosure

Enclosure # 1 <0.01Outside Of Decontamination

1200 SFThird FloorHallway

8/10/2006003-0004 Negative Pressure Enclosure

AdjacentFloor Tile Enclosure

Enclosure # 1 <0.01Outside Of Decontamination

1200 SFThird FloorHallway

8/10/2006003-0005 Negative Pressure Enclosure

Final ClearanceFloor Tile Enclosure

Enclosure # 1 <0.01Outside of Room 2215

1200 SFThird FloorHallway

8/10/2006003-0006 Negative Pressure Enclosure

Final ClearanceFloor Tile Enclosure

Enclosure # 1 <0.01Outside of Room 2215

1200 SFThird FloorHallway

8/10/2006003-0007 Negative Pressure Enclosure

Final ClearanceFloor Tile Enclosure

Enclosure # 1 <0.01Outside of Room 2213.

1200 SFThird FloorHallway

8/10/2006003-0008 Negative Pressure Enclosure

Final ClearanceFloor Tile Enclosure

Enclosure # 1 <0.01Outside of Room 2213.

1200 SFThird FloorHallway

8/10/2006003-0009 Negative Pressure Enclosure

Final ClearanceFloor Tile Enclosure

Enclosure # 1 <0.01Outside of Room 2210.

1200 SFSecond FloorHallway

8/11/2006002-0001 Negative Pressure Enclosure

AdjacentFull EnclosureEnclosure # 2 <0.01

Outside Of Decontamination

1200 SFSecond FloorHallway

8/11/2006002-0002 Negative Pressure Enclosure

AdjacentFull EnclosureEnclosure # 2 <0.01

Outside Of Decontamination

1200 SFSecond FloorHallway

8/11/2006002-0003 Negative Pressure Enclosure

AdjacentFull EnclosureEnclosure # 2 <0.01

Outside Of Decontamination

Tuesday, December 19, 2006 Page 1 of 2

© Nova Consulting Group, Inc.

Page 10: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Air Sample Results by Enclosure

Building NumberBuilding Name Murray Junior High School

Project Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District Building Address: 2200 Buford Ave.

St. Paul MN. 55108

AreaLocationRoom Number

Enclosure NumberEnclosure Type

DateCollected

Sample NumberSample Location

Type ofSample

Sub-Typeof Sample

Result

1200 SFSecond FloorHallway

8/11/2006002-0004 Negative Pressure Enclosure

AdjacentFull EnclosureEnclosure # 2 <0.01

Outside Of Decontamination

1200 SFSecond FloorHallway

8/11/2006002-0005 Negative Pressure Enclosure

Final ClearanceFull EnclosureEnclosure # 2 <0.01

In Front Of Room 1216.

1200 SFSecond FloorHallway

8/11/2006002-0006 Negative Pressure Enclosure

Final ClearanceFull EnclosureEnclosure # 2 <0.01

In Front Of Room 1216.

1200 SFSecond FloorHallway

8/11/2006002-0007 Negative Pressure Enclosure

Final ClearanceFull EnclosureEnclosure # 2 <0.01

In Front Of Room 1216.

1200 SFSecond FloorHallway

8/11/2006002-0008 Negative Pressure Enclosure

Final ClearanceFull EnclosureEnclosure # 2 <0.01

In Front Of Room 1210.

1200 SFSecond FloorHallway

8/11/2006002-0009 Negative Pressure Enclosure

Final ClearanceFull EnclosureEnclosure # 2 <0.01

North End Hallway.

Tuesday, December 19, 2006 Page 2 of 2

© Nova Consulting Group, Inc.

Page 11: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

APPENDIX B

AIR SAMPLE RESULTS DETAIL

Page 12: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Collected ByDate

CollectedSampleNumber

Sub-Typeof Sample

Numberof Fields

DateAnalyzed Analyzed By

TotalFibers

GraticuleArea

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Air Sample Results Detail

Building NumberBuilding Name Murray Junior High School

Project Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District Building Address 2200 Buford Ave.

St. Paul MN. 55108

Collection Information Analysis InformationType ofSample

BlankValue

FiberDensity

Concen-trationVolume

CalibratedFlow Rate

Jason Karpe8/9/2006 003-0001

Adjacent

Adjacent Sample Passed.

1008/9/2006 Jason Karpe 210.00785

Note:

Negative Pressure Enclosure

02778.4 26.75 <0.0115.1

Jason Karpe8/9/2006 003-0002

Adjacent

Adjacent Samples Passed.

1008/9/2006 Jason Karpe 130.00785

Note:

Negative Pressure Enclosure

02745.4 16.56 <0.0114.84

Jason Karpe8/9/2006 B-0001 Adjacent 1008/9/2006 Jason Karpe 00.00785Blank 00 0 0 fibers0

Jason Karpe8/10/2006 003-0003

Adjacent

Adjacent Samples.

1008/10/2006 Jason Karpe 140.00785

Note:

Negative Pressure Enclosure

02168.6 17.83 <0.0115.06

Jason Karpe8/10/2006 003-0004

Adjacent

Adjacent Samples.

1008/10/2006 Jason Karpe 90.00785

Note:

Negative Pressure Enclosure

02173.6 11.46 <0.0115.2

Jason Karpe8/10/2006 003-0005

Final Clearance

Final Clearance Passed.

1008/10/2006 Jason Karpe 90.00785

Note:

Negative Pressure Enclosure

02298 11.46 <0.0115.32

Tuesday, December 19, 2006 Page 1 of 4

© Nova Consulting Group, Inc.

Page 13: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Collected ByDate

CollectedSampleNumber

Sub-Typeof Sample

Numberof Fields

DateAnalyzed Analyzed By

TotalFibers

GraticuleArea

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Air Sample Results Detail

Building NumberBuilding Name Murray Junior High School

Project Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District Building Address 2200 Buford Ave.

St. Paul MN. 55108

Collection Information Analysis InformationType ofSample

BlankValue

FiberDensity

Concen-trationVolume

CalibratedFlow Rate

Jason Karpe8/10/2006 003-0006

Final Clearance

Final Clearance Passed.

1008/10/2006 Jason Karpe 80.00785

Note:

Negative Pressure Enclosure

02260.5 10.19 <0.0115.07

Jason Karpe8/10/2006 003-0007

Final Clearance

Final Clearance Passed.

1008/10/2006 Jason Karpe 140.00785

Note:

Negative Pressure Enclosure

02260.2 17.83 <0.0114.87

Jason Karpe8/10/2006 003-0008

Final Clearance

Final Clearance Passed.

1008/10/2006 Jason Karpe 120.00785

Note:

Negative Pressure Enclosure

02378.8 15.29 <0.0115.65

Jason Karpe8/10/2006 003-0009

Final Clearance

Final Clearance Passed.

1008/10/2006 Jason Karpe 120.00785

Note:

Negative Pressure Enclosure

02330.2 15.29 <0.0115.33

Jason Karpe8/11/2006 002-0001

Adjacent

Adjacent Sample.

1008/11/2006 Jason Karpe 80.00785

Note:

Negative Pressure Enclosure

02296.7 10.19 <0.0115.11

Tuesday, December 19, 2006 Page 2 of 4

© Nova Consulting Group, Inc.

Page 14: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Collected ByDate

CollectedSampleNumber

Sub-Typeof Sample

Numberof Fields

DateAnalyzed Analyzed By

TotalFibers

GraticuleArea

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Air Sample Results Detail

Building NumberBuilding Name Murray Junior High School

Project Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District Building Address 2200 Buford Ave.

St. Paul MN. 55108

Collection Information Analysis InformationType ofSample

BlankValue

FiberDensity

Concen-trationVolume

CalibratedFlow Rate

Jason Karpe8/11/2006 002-0002

Adjacent

Adjacent Sample.

1008/11/2006 Jason Karpe 110.00785

Note:

Negative Pressure Enclosure

02291.9 14.01 <0.0114.98

Jason Karpe8/11/2006 002-0003

Adjacent

Morning Adjacent Samples.

1008/11/2006 Jason Karpe 70.00785

Note:

Negative Pressure Enclosure

02543.5 8.92 <0.0115.14

Jason Karpe8/11/2006 002-0004

Adjacent

Morning Adjacent Samples.

1008/11/2006 Jason Karpe 110.00785

Note:

Negative Pressure Enclosure

02479.7 14.01 <0.0114.76

Jason Karpe8/11/2006 002-0005

Final Clearance

Finals

1008/11/2006 Jason Karpe 90.00785

Note:

Negative Pressure Enclosure

02085.8 11.46 <0.0115.45

Jason Karpe8/11/2006 002-0006

Final Clearance

Finals

1008/11/2006 Jason Karpe 120.00785

Note:

Negative Pressure Enclosure

02099.3 15.29 <0.0115.55

Tuesday, December 19, 2006 Page 3 of 4

© Nova Consulting Group, Inc.

Page 15: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Collected ByDate

CollectedSampleNumber

Sub-Typeof Sample

Numberof Fields

DateAnalyzed Analyzed By

TotalFibers

GraticuleArea

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Air Sample Results Detail

Building NumberBuilding Name Murray Junior High School

Project Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District Building Address 2200 Buford Ave.

St. Paul MN. 55108

Collection Information Analysis InformationType ofSample

BlankValue

FiberDensity

Concen-trationVolume

CalibratedFlow Rate

Jason Karpe8/11/2006 002-0007

Final Clearance

Finals

1008/11/2006 Jason Karpe 120.00785

Note:

Negative Pressure Enclosure

02069.6 15.29 <0.0115.33

Jason Karpe8/11/2006 002-0008

Final Clearance

Finals

1008/11/2006 Jason Karpe 100.00785

Note:

Negative Pressure Enclosure

02082.2 12.74 <0.0114.98

Jason Karpe8/11/2006 002-0009

Final Clearance

Finals

1008/11/2006 Jason Karpe 90.00785

Note:

Negative Pressure Enclosure

02121.1 11.46 <0.0115.26

Jason Karpe8/11/2006 B-0002 Adjacent 1008/11/2006 00.00785Blank 00 0 0 fibers0

Tuesday, December 19, 2006 Page 4 of 4

© Nova Consulting Group, Inc.

Page 16: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

APPENDIX C

SAMPLE LOCATION MAPS

Page 17: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Second Floor Murray Junior High School 2200 Buford Ave,. St. Paul MN. 55108

JOB NUMBER 8/10/06

Floor 2Consulting Group, Inc.

EnvironmentalArchitectureEngineering

Key

M

Decon Unit

HEPA MachineManometer

Sample Location

Enclosure Boundary

H

001-0001

D E C O NStairs

Elevator

Stairs To Main Entrance

Room 1203

Room 1205

Room 1207

Room 1209

Room 1211

Closet

D C NE

O

Hallway

Boys

Girls

Room 1212

Room 1214

Room 1216

Room 1218

Restroom

Room 1222

To Auditorium

Room 1206

Room 1204

H H

M

Room 1202

H06- 0946

Bagout

Samples 002-0005002-0006002-0007

x x x

Sample 002-0008

x

Sample

002-0009x

Samples 002-0001 and 0003

x x

amples 002- 0002, 002-0004

xx

Page 18: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Floor 03

Murray Junior High School 2200 Buford Ave.St. Paul MN. 55108

JOB NUMBER

Aug 9, 2006

Floor 03Consulting Group, Inc.

EnvironmentalArchitectureEngineering

Key

M

Decon Unit

HEPA MachineManometer

Sample LocationEnclosure Boundary

H

001-0001

D E C O N

Abat

emen

t Are

a

Room 2215

Room 2213

Room 2209

Room 2211

Room 2207

Stairs

Elevator

Room 2216

Room 2214

Room 2212

Room 2210

Room 2208

Girls Restroom

Room 2202

Room 2203Room 2201Lockers

H

D C O NEStairs

Samples 003-0001,0002,0003,0004

x x M

1200

SF

H06-0946

/Hallway

Samples 003-0009003-0008003-0007

x x x

Samples003-0006003-0005

X X

Page 19: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

APPENDIX D

DAILY LOG REPORTS

Page 20: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Daily Log

Building NumberBuilding Name Murray Junior High School

Contractor Name Twell EnviornmentalContractor License Number 592

Consultant License NumberConsultant Name Nova Consulting GroupProject Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District

Daily Log Date 8/8/2006Environmental Specialist Jason Karpe

License Number

Contractor 9.0Consultant 1.5

Total Worker Hours

Log EntriesTime Description

Start Time End Time BreaksCrewSize

ShiftHours

Consultant Time Sheet

2:30 PM 4:00 PM 0.0 1 1.5Start Time End Time Breaks

CrewSize

ShiftHours

Contractor Time Sheet

2:00 PM 3:30 PM 0.0 6 1.5

2:00 PM Twell arrives onsite and begins to mobilze equipment to the Third Floor.2:30 PM Twell begins to critical of vents and other areas of importance. Nova arrives onsite and begins to set up work area

and pumps for the abatement process.3:00 PM Twell works on criticals and Nova gathers information to generate Jazz report.3:30 PM Twell is close to completing the prep work and will be starting abatement sometime in the morning on

Wednesday. The building closes at 15:30 so work will resume in the morning.4:00 PM Nova is allowed to work a little while longer to unload equipment and finalize data enteries.

Tuesday, December 19, 2006 Page 1 of 4

© Nova Consulting Group, Inc.

Page 21: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Daily Log

Building NumberBuilding Name Murray Junior High School

Contractor Name Twell EnviornmentalContractor License Number 592

Consultant License NumberConsultant Name Nova Consulting GroupProject Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District

Daily Log Date 8/9/2006Environmental Specialist Jason Karpe

License Number

Contractor 48.0Consultant 8.5

Total Worker Hours

Log EntriesTime Description

Start Time End Time BreaksCrewSize

ShiftHours

Consultant Time Sheet

7:00 AM 3:30 PM 0.0 1 8.5Start Time End Time Breaks

CrewSize

ShiftHours

Contractor Time Sheet

7:00 AM 3:30 PM 0.5 6 8.0

7:00 AM Twell and Nova arrive onsite. Twell works on critical barriers and putting up the Decontamination Unit. Nova oversees the work that is being perfomrd

7:30 AM Twell works on the critical barriers as Nova prepares pumps for PCM Samples8:00 AM Twell has completed critical barriers and ask Nova to do a visual inspection of the area. Nova walks through

makes suggestions on splash guards for the lockers. Twell agrees with the idea and the area passes inspection.8:15 AM Twell is ready to enter the containment and Nova prepares to start Adjacent Samples 003-0001 and 003-0002.8:30 AM The Abatement has begun and Nova monitors the manometer. The reading is -0.023.9:00 AM Abatement work continues and Nova is informed that under the tile appears a tar paper type material. Twell will

treat the material as ACM and dispose of the waste in the Fiber Barrels.9:30 AM Twell works on the abatement of the tile and Nova enters data into the Jazz program.10:00 AM Twell Supervisor leaves site to pick up neccesary paper work for Murray Junior High School. Nova monitors work

in the continment.10:30 AM Twell works in the Enclosure on the third floor and Nova works on updating Jazz file.11:00 AM Twell begins to put ACM in fiber barrels and start to remove mastic from the floor. Nova pulls morning PCM

samples and gets prepared to analyze the slides.11:30 AM Twell cleans up containment area and finishes putting ACM in barrels. Twell breaks for lunch.12:00 PM Twell returns and workers suit up for entry into the Enclosure.12:30 PM Nova checks Negative Air and finds that the level has increased to -0.18. Nova mentions to Twell Supervisor the

finding. Nova starts afternoon adjacents 003-0003 and 003-0004.1:00 PM Twell is finding that the mastic is coming up slower than anticipated.1:30 PM Nova finishes with analysis on samples 003-0001 and 003-0002.2:00 PM Twell works on mastic removal and Nova generates map for the Enclosure.2:30 PM Mastic is coming up slowly but workers are making progress.3:00 PM Nova sets up pumps for Finals that will be ran on Thursday. Twell continues with removal of mastic.3:30 PM Nova has finished reading samples 003-0003 and 003-0004 the results show the samples have passed. Work will

continue in the AM.

Tuesday, December 19, 2006 Page 2 of 4

© Nova Consulting Group, Inc.

Page 22: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Daily Log

Building NumberBuilding Name Murray Junior High School

Contractor Name Twell EnviornmentalContractor License Number 592

Consultant License NumberConsultant Name Nova Consulting GroupProject Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District

Daily Log Date 8/10/2006Environmental Specialist Jason Karpe

License Number

Contractor 48.0Consultant 0.0

Total Worker Hours

Log EntriesTime Description

Start Time End Time BreaksCrewSize

ShiftHours

Consultant Time Sheet

7:00 AM 3:30 PM 0.0 0 8.5Start Time End Time Breaks

CrewSize

ShiftHours

Contractor Time Sheet

7:00 AM 3:30 PM 0.5 6 8.0

7:00 AM Twell arrives onsite and begins to remove barrels containing ACM from the third floor. Nova assists workers with the safe removal of the barrels.

7:30 AM Twell workers continue to remove mastic from floor. Nova prepares pumps for finals later in the morning.8:00 AM Twell works on clean up in the containment. Nova helps prep floor two.8:30 AM Twell has completed clean up in containment and are ready for a visual inspection.9:00 AM Nova does visual inspection and passes the containment. Finals will be ran shortly following the visual clearance.9:30 AM Nova has started Final Clearance Samples 003-0005 through 0009. The Samples will be analyzed at

approximently at 12:0010:00 AM Twell workers continue with critical barriers on second floor. Nova visually inspects prep work performed by Twell.10:30 AM Twell works on critical barriers and Nova draws map of second floor Enclosure.11:00 AM Twell continues to work on criticals Nova draws maps.11:30 AM Twell waits for finals to be completed to so that they can use the HEPA Unit and the Decontamination Unit for the

Enclosure 02. Twell takes lunch break Nova waits for samples.12:00 PM Twell returns from break and waits for Nova to finish reading samples.12:30 PM Nova finishes analyzing Final Samples and all samples pass.1:00 PM Twell puts Decontamination Unit and HEPA filters into position in Enclosure 02. Nova enters data into Jazz.1:30 PM Twell suit up and prepare to enter containment. Nova starts afternoon Adjacent Samples.2:00 PM Twell continues with removal of Floor Tile as Nova enters data into Jazz program.2:30 PM Twell has started with mastic removal and sealing barrels that contain ACM.3:30 PM Twell will continue with the removal of mastic in the morning. Nova pulls afternoon adjacents and will read results

in the morning.

Tuesday, December 19, 2006 Page 3 of 4

© Nova Consulting Group, Inc.

Page 23: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Daily Log

Building NumberBuilding Name Murray Junior High School

Contractor Name Twell EnviornmentalContractor License Number 592

Consultant License NumberConsultant Name Nova Consulting GroupProject Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District

Daily Log Date 8/11/2006Environmental Specialist Jason Karpe

License Number

Contractor 48.0Consultant 8.5

Total Worker Hours

Log EntriesTime Description

Start Time End Time BreaksCrewSize

ShiftHours

Consultant Time Sheet

7:00 AM 3:30 PM 0.0 1 8.5Start Time End Time Breaks

CrewSize

ShiftHours

Contractor Time Sheet

7:00 AM 3:30 PM 0.5 6 8.0

7:00 AM Twell has mobilized into the building and is getting suited up to enter the Enclosure.7:30 AM Nova starts Adjacent Samples and Twell begins with mastic removal.8:00 AM Nova monitors Negative Air and monitors critical barriers inside the containment.8:30 AM Mastic removal is moving along and the Adjacent pumps are running properly. Nova reads afternoon Adjacent

Samples from 8/10/06.9:00 AM Twell continues with mastic removal. Nova updates jazz program and generates map of second floor.9:30 AM Twell workers remove mastic and load ACM containing material into fiber barrels.10:00 AM Nova makes visual inspection of containment and finds that all critical barriers are secured.10:30 AM Twell workers begin to bagout fiber barrels through the back hallway. Nova makes visual inspection of

containment and finds that areas of the floor need work. Twell enters the containment and continue to work on floor. Nova still feels that floor needs improvement so workers continue.

11:00 AM Twell has started removing carpet in basement hallways near the elevator. Nova makes point that floor filler should be removed from Second Floor but Twell Supervisor insists that it should stay. Twell breaks for lunch.

11:15 AM Nova starts finals on the Second Floor Enclosure.11:30 AM Twell returns from lunch and continue to remove carpet. Twell is removing approximently 1100 SF of carpet.12:00 PM Nova watches removal of carpet and analyzes samples from the morning.12:30 PM Morning Adjacents pass requiement.1:00 PM Twell removes rolls of old carpet to the trailer. Nova waits for samples to cycle through1:30 PM Twell removes carpet and loads into trailer. Nova prepares to pull samples from the containment area.2:00 PM Twell Supervisor leaves site to drop off trailer containing ACM Barrrels at the dumpster located at Mississippi

Elementary.2:15 PM Nova analyzes final samples and clear the containment safe to enter.2:45 PM Twell sweeps carpet area and finishes bagging critical barriers from second floor.3:15 PM Twell loads up equipment into trailer as Nova works on drawing maps.3:30 PM Nova and Twell leave site for the weekend.

Tuesday, December 19, 2006 Page 4 of 4

© Nova Consulting Group, Inc.

Page 24: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

APPENDIX E

PERSONNEL CERTIFICATION FORM

Page 25: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Nova Consulting Group, Inc.

Personnel Certification Report

Client Number: STPAU006Project Number: H06-0946 Client Name: Saint Paul School DistrictProject Location: 2nd & 3rd Floor Hallways

I hereby certify that this project was completed by me or under my supervision.

Air Monitoring/Sampling Professional Certification Number Expiration DateEPA / State

Jason Karpe TDAI-H06-1306-02

Asbestos Consultant Certification Number Expiration DateEPA / State

Jason Karpe

Asbestos Contractor/Supervisor Certification Number Expiration DateEPA / State

Allen L. Nitti AS8441 10/21/2006 10/21/2006

Asbestos Worker Certification Number Expiration DateEPA / State

Javier Morales AW9390 7/15/2007 10/21/2006

Jesus Montes Morales AW8587 7/15/2007 10/21/2006

Pedro Martinez AW9148 3/4/2007 10/21/2006

Roberto Martinez AW8960 5/14/2007 10/21/2006

Santiago Gonzales AW9632 6/10/2007 10/21/2006

NIOSH 582E Certification Number Expiration DateEPA / State

Jason Karpe NIOSH-H06-1306-02

Tuesday, December 19, 2006

© Nova Consulting Group, Inc.

Page 26: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

APPENDIX F

WASTE TRACKING

Page 27: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Waste Tracking Report

Building NumberBuilding Name Murray Junior High School

Project Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District Building Address: 2200 Buford Ave.

St. Paul MN. 55108

Removal Date Immediate Destination Final Destination Type of Transport Note8/10/2006 Twell Trailer SKB Landfill Truck

Container Fiber Barrels Quantity 14 NoteContainer Poly Bags Quantity 10 Note

8/11/2006 Twell Trailer SKB Landfill TruckContainer Fiber Barrels Quantity 16 Note Barrels contain ACM Floor Tiles and Mastic.Container Poly Bags Quantity 14 Note

Tuesday, December 19, 2006 Page 1 of 1

© Nova Consulting Group, Inc.

Page 28: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

APPENDIX G

DAILY MICROSCOPE CHECKLIST

Page 29: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Nova Consulting Group, Inc.1107 Hazeltine Boulevard, Suite #400Chaska, MN 55318

Daily Microscope Report

Building NumberBuilding Name Murray Junior High School

Project Number H06-0946

Client Number STPAU006

Project Description Floor Tile AbatementClient Name Saint Paul School District Building Address 2200 Buford Ave.

St. Paul MN. 55108

FocusCondenser

CenterPhaseRings

Adjust InterocularDistance

FocusIndividualOculars

Date MicroscopeIdentifier

EnvironmentalSpecialist

NIOSH Cert.Number

CalibrationDate

8/9/2006 11/21/2005PCM-953 Jason Karpe NIOSH-H06-1306-02Check Check Check Check8/10/2006 11/21/2005PCM-953 Jason Karpe NIOSH-H06-1306-02Check Check Check Check8/11/2006 11/21/2005PCM-953 Jason Karpe NIOSH-H06-1306-02Check Check Check Check

Tuesday, December 19, 2006 Page 1 of 1

© Nova Consulting Group, Inc.

Page 30: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

APPENDIX H

PERSONNEL CERTIFICATIONS

Page 31: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Issue Date: May 19, 2006Expiration Date: May 19, 2007 Diploma No.: CSI-H06-1306-02

Nova Consulting Group, Inc.

Certifies that

Jason Karpe

Has attended and successfully completed theContractor/Supervisor Initial Training Course

"Practices and Procedures for Asbestos Abatement Projects"presented in Chaska, Minnesota on

May 15, 2006

Course has been permitted by the State of Minnesotaunder Minnesota Rules, parts 4620.3702 to 4620.3722

and the U.S. EPA under Title II of TSCA, 40 CFR Part 763 (AHERA)

Charles E. EasleyCourse Director

Nova Consulting Group, Inc. - 1107 Hazeltine Boulevard, Suite #400 - Chaska, MN 55318Telephone: (612) 448-9393 FAX: (612) 448-9572

Page 32: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor
Page 33: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Issue Date: May 25, 2006 Diploma No.: NIOSH-H06-1306-02

Nova Consulting Group, Inc.

Certifies that

Jason Karpe

Has attended the“Asbestos In Buildings: Air Sampling and Analysis”

-- A NIOSH 582 EQUIVALENT -- Coursepresented in Chaska, Minnesota on

May 22, 2006 - May 25, 2006

and has satisfactorily passed an examination that meetsall criteria required for the course given on

May 25, 2006

Charles E. EasleyCourse Director

Nova Consulting Group, Inc. - 1107 Hazeltine Boulevard, Suite #400 - Chaska, MN 55318Telephone: (952) 448-9393 FAX: (952) 448-957

Page 34: AIR MONITORING REPORT€¦ · Nova Consulting Group, Inc. (Nova) provided on-site air monitoring during the removal of asbestos-containing materials located in the 2nd & 3rd Floor

Issue Date: May 26, 2006 Diploma No.: TDA-H06-1306-02

Nova Consulting Group, Inc.Certifies that

Jason Karpe

Has attended and successfully completed theMinnesota Two Day

Asbestos Air Sampling Coursepresented in Chaska, Minnesota on

May 25, 2006 - May 26, 2006

Course has been permitted by the State of Minnesotaunder Minnesota Rules, parts 4620.3702 to 4620.3722

Charles E. EasleyCourse Director

Nova Consulting Group, Inc. - 1107 Hazeltine Boulevard, Suite #400 - Chaska, MN 55318Telephone: (952) 448-9393 FAX: (952) 448-9572