air doors / air curtains...19 ac 401 21 ac 403 23 ac 500 25 ac 700 27 ac 800 29 ac 1000 31 ac 1001...
TRANSCRIPT
-
AIR DOORS / AIR CURTAINS2013-2014
-
2013-2014 Series: Air Curtains/ Air Doors.
9 AC 100
11 AC 200
13 AC 300
15 AC 301
17 AC 400
19 AC 401
21 AC 403
23 AC 500
25 AC 700
27 AC 800
29 AC 1000
31 AC 1001
33 AC 1002
ABOUTHEAT SAVING SYSTEMS
CONTENTS
Heat Saving Systems Inc. takes pride in supplying the highest quality air curtains to the market. Incorporating both functionality and elegant design, many years of development have gone into the current line of models. All the models have proven their durability over many years of reliable service, and are designed for maximum efficiency, performance and aesthetic appeal. Our air curtains are designed utilizing technology from NPO Teplomash, a
leading manufacturer of industrial, commercial and residential heating and ventilating equipment in Europe and Russia since 1992. As one of their product lines, the company produces over 70,000 air curtains a year. All of Heat Savings Systems air curtains conform to current technical standards and are ETL certified for all jurisdictions in North American. We have models to service all your industrial and commercial applications, as well
as several decorative units that will aesthetically fit into the front lobbies and entrances of offices, condominiums and institutional buildings.
General Information: Air Curtains/Air Doors.
3 Utility and Cost Savings
3 Increased Building Efficiency
3 Model Specifications
3 Applications and Construction
4 Quick Reference Guide
5 Model Selection Guide
6 Operation Conditions
6 Product Code Description
6 Control Panel
7 Maximum amperage ratings
-
3
Air Flow
When sizing a unit, must consider:
• Size of opening• Exterior median low temperature• Interior ambient temperature
required• Building air systems…positive
or negative pressures• Exterior wind factors• Water systems – hot water temp.,
flows in litres or gallons per minute• Building or area volume• Pedestrian or commercial traffic
at entryway
GENERAL INFORMATION:AIR CURTAINS / AIR DOORS
Air Curtain / Air Door:
• Creates a barrier by blocking the entry of outside air into a building, or escaping air from the interior of the premises
• Minimizes the use of existing HVAC equipment to make up for heat losses or gains
• Will increase the efficiency of existing vestibules, or may replace the need for building one
• Improves employee efficiency by not having to stop to open and close doors
• Maintains comfortable ambient temperatures around entrances and doorways for both customer and employees
• Allows for open doors, to increase customer traffic in retail environments
• Can act as both an energy saving device, and, as supplementary or primary fan heater
• Dry off floors in entrance ways for safety
• Effective in both heated and air-conditioned spaces, as well as walk in coolers and freezers for interior applications.
Heat Saving Systems manufactures the highest quality air curtains for whatever your requirements may be. Designed to protect against energy losses through openings, when correctly sized and installed efficiencies of up to 80% can be achieved, as compared to a space with no air curtain installed.
Utility and Cost Savings
Increased Building Efficiency
General Information: Air Curtains / Air Doors
Heat Saving Systems has a complete range of models for all industrial, commercial and institutional applications, as well as several decorative units. Available as electric or water heated, or unheated (ambient).
• Steel casing coated with high-quality durable polymer coatings
• Fans – cross flow impellers, centrifugal and axial
• Motors – external rotor for superior cooling and heat dissipation, less vibration, motor and bearings sealed, higher efficiency and longer operating life
• Thermal protection – motors built-in, heating elements thermal relay protected
• Thermal high and low fan limit switches
• Overcurrent protection – air curtain circuits are breaker protected
• Electric heating elements - straight stainless steel elements with stainless steel fins
• Water heated units – heat exchanger copper tubing with aluminum fins for efficient heat transfer. Rated for up to 70lbs psi. Equipped with drains in case of freezing risk
• All (non-decorative) units can be installed horizontally or vertically
• Complete with control panels• Decorative models available in
polished or matte stainless steel.
Heat Saving Systems has a full range of air curtains for all applications, and have been installed and proven to be effective in all types of buildings and regional climates. Many factors must be considered when specifying a unit above and beyond the size of opening being considered, especially where high traffic areas, large area or volume buildings, extremes interior and exterior temperature variables, the intended use etc., Heat Saving Systems engineers will assist in model selection and installation suggestions. For further information see “Model Selection Guide”, page 5.
Model Specifications Model Specifications
Applications and Construction
The various models are available in 39”, 59” and 79” and can be mounted in tandem, either horizontally or vertically to make up any opening size dimension. Each Air Curtain supplied with Control Panel. Air curtains are energy saving devices, typically installed in a building over an exterior opening. An air curtain can function in two dierent ways.1. As a supplementary heater in an area. The air curtain will minimally block the transfer of air, but, if the exterior air does come in, it will be heated to maintain an ambient preset interior temperature in the immediate area making it more comfortable for customers or employees. Requires less power, air flow may be less disruptive to pedestrian traffic, does not require that the specification for a particular unit take into account major fluctuations in wind factors, building air pressure imbalances or high traffic patterns.2. To block the transfer of air form exterior to interior. Typically will require more air and heat output for a given opening, and more precise specification of model required. Typically for commercial or industrial applications, higher efficiencies are gained by blocking the air transfer in large buildings, or high traffic areas.
-
5General Information: Air Curtains / Air Doors General Information: Air Curtains / Air Doors
AC200AC100 AC300 AC400 AC500 AC700 AC8000
1
2
3
4
5
6
7
8
9
10
11
12
up to 7.2 ftup to 8.2 ft
up to 11.5 ft
up to 16.4 ft
up to 19.7 ft
up to 23 ft
up to 40 ftm
Commercial and industrial Air Сurtains / Air Doors
Model Selection GuideQUICK REFERENCE GUIDE FOR AIR CURTAIN MODELS
Decorative Air Curtains / Air Doors
0
1
2
3
m
m
up to 11.5 ft up to 11.5 ft up to 11.5 ft
AC403 AC1000 AC1002
AC1001
01234
up to 11.5 ft
TABLE 1.2 EFFECTIVE AIR STREAM LENGTH AT 3 3.1 ft/s (4m/s) WIND
GRADATION OFCONDITIONS
APERTURE HEIGHT (ft/m)
6.5/2.0 8.2/2.5 9.84/3.0 11.5/3.5 13.1/4.0 16.4/5.0 19.7/6.0 26.2/8.0
≥ ≥32 °F/ 0 °C 100Е opt
200Е opt
200W opt
100Е sat
200Е sat
200W sat
З00Е opt
300W opt
З00Е opt
300W opt
З00Е opt (30°) 400Е opt (10°)
400W opt (10°)
400E opt (20°)
400W opt (20°)
500W opt (15°)
700W opt (10°)
700W opt (30°)
700W opt (0°)
From 32 to 14 °F/
From 0 to- 10 °C
100Е sat
200Е opt
З00Е opt200W opt
300W opt
З00Е opt
300W sat
300W sat 400Е opt (15°)
300W sat (30°)
400W opt (15°)
400Е opt (30°)
400W op (30°)
400Е sat (30°)
400W sat (30°)
500W opt (30°)
500W sat (30°)
700W opt (30°)
700W sat (30°)
From 14 to- 13 °F/
From -10 to -25 °C
200Е sat
З00Е sat
300W sat
З00Е sat
300W sat
400Е opt (30°)
400W opt (30°)
400Е sat (30°)
400W sat (30°)
400Е sat (30°)
400W sat (30°)
500W opt (30°)
700W opt (20°) 700W sat (30°) -
From -13 to- 40 °F/
From -25 to- 40 °C
400E opt (15°)
400W opt (15°)
400Е opt (30°)
400W opt (30°)
400Е sat (30°)
400W sat (30°)
500W opt (30°)
500Е sat (10°) 500W opt (30°)
700W opt (10°)
700W sat (30°) - -
TABLE 1.1 EFFECTIVE AIR STREAM LENGTH AT 3.24 ft/s (1m/s) WIND
GRADATION OFCONDITIONS
APERTURE HEIGHT (ft/m)
6.5/2.0 8.2/2.5 9.84/3.0 11.5/3.5 13.1/4.0 16.4/5.0 19.7/6.0 26.2/8.0
≥ ≥32 °F/ 0 °C 100Е opt
200Е opt
200W opt
100Е sat
200Е opt
200W opt
300Е opt
300W opt
300Е opt
300W opt
400Е opt (0°)
400W opt (0°)
400Е opt (0°)
400W opt (0°)
500W opt (0°)
700W opt (0°)
500W sat (30°)
700W opt (0°)
From 32 to 14 °F/
From 0 to- 10 °C
100Е sat
200Е opt
200W opt
200Е opt
200W opt
300Е sat
300W sat
300Е sat
300W opt
400Е opt (20°)
400W opt (20°)
500W opt (0°)
400Е opt (30°)
400W opt (30°)
500W opt (15°)
500W opt (30°)
700W opt (0°)
700W opt (30°)
From 14 to- 13 °F/
From -10 to -25 °C
200Е sat
200W sat
300W opt
300Е opt
300W opt
300Е sat
400Е opt (20°)
300W sat
400W opt (20°)
400Е opt (30°)
400W opt (30°)
400Е sat (30°)
400W sat (30°)
500W opt (15°)
700W opt (0°)
400Е sat (30°)
400W sat (30°)
500W sat (30°)
700W opt (10°)
700W opt (30°) 700W sat (30°)
From -13 to -40 °F/
From -25 to -40 °C
300Е opt
300W opt
400Е opt (15°)
300W sat
400W opt (15°)
400Е opt (30°)
400W opt (30°)
500W opt (30°) 500W sat (30°)
700W opt (30°)
700W sat (30°) - -
Data referred for:• Series 100-300 operate as a supplementary heating, see page 3 “Application and Construction”, paragraph 1. • Series 400-700 operate as specified in paragraph 2. see page 3 “Application and Constuction”.• Water heated Air Curtains, input and output water temp 203/158 °F (95/70 °C).• “Opt” - optimal - the average air temperature at nozzle is from 15.6 °F (12 °C) to 64.4 °F (18 °C).• “Sat” - satisfactory - the average air temperature at nozzle is from 41 °F(5 °C) to 15.6 °F (12 °C).• In the cells (15°) (20°) (30°) means the angles of air stream relative to the plane of the opening.• In some conditions, to optimize performance, or, in extreme weather conditions, air curtains can be installed vertically on either side of an opening. In such cases, for model selection, use 0.7 of the rated opening size applicable to that particular model.
All recommendations below are to be used as a guideline only, and apply only to buildings and areaswith balanced air systems as well as temperature ranges and wind conditions as stated. Because mostapplications are unique, a more detailed analysis and/or engineered specication generally required.
-
7
Air Flow
General Information: Air Curtains / Air Doors
Operation Conditions Electric / Water Heated Air Curtains Product Code Description
• Relative ambient air temperature, -4…+104 oF/ -20…+40 oC• Air moisture level at no more than 68 oF (+20oC), 80%• Dust and other dirt in the air, no more than 10 mg/m3• There should be no condensation or presence of substances that are
aggressive to carbon steels (acids, alkalis), adhesive and inflammable, or fibrous (oleoresins, industrial fiber) in the air.
• For Water Heated Air Curtains hot and overheated water is used as a heating agent, with the following characteristics:a. operating pressure ≤ 1.2 MPab. temperature ≤ 302 oF (150 oC).
ExampleAC300-79E21
AC Air Curtain 300 series
39, 59, 79 length in inches
E, W, A Electric, water, ambient
21 Heater power, kW
General Information: Air Curtains / Air Doors
Control Panel
Unit NameHeating
elements
Available Voltage
208/1/60 208/3/60 480/3/60 600/3/60
АС300-79
Е21
70 32 27
АС400-59 65 33 24
АС400-79 65 33 24
АС401-59 63 30 23
АС401-79 63 30 23
АС403-59 65 33 25
АС403-79 65 33 25
АС1000-79 65 33 25
АС1001-79 70 32 24
АС1002-79 65 33 25
АС400-79
Е32
96 35 37
АС401-79 94 32 34
АС403-79 96 35 37
АС1000-79 96 35 37
АС1002-79 96 35 37
АС1000-79
Е43
125 59 48
АС1002-79 125 59 48
Unit NameHeating
elements
Available Voltage
208/1/60 208/3/60 480/3/60 600/3/60
АС100-31 Е3 13
АС100-31 Е4 17,5
АС100-31
Е5
24
АС200-39 26 15 7 6
АС200-59 26 15 7 6
АС300-39 26 15 7 6
АС200-39
Е8
23 10 8
АС200-59 24 11 9
АС300-39 23 10 8
АС300-59 24 11 9
АС400-39 26 13 11
АС403-39 26 13 11
АС200-59
Е11
30 14 11
АС300-39 30 14 11
АС300-59 31 15 12
АС300-79 31 15 12
АС400-39 33 17 14
АС400-59 36 20 17
АС401-59 33 17 14
АС403-39 33 17 14
АС403-59 36 20 17
АС1001-79 31 15 12
АС300-59 Е13 39 19 15
АС300-79
Е16
48 22 19
АС400-39 48 22 19
АС400-59 51 25 22
АС400-79 51 25 22
АС401-59 48 22 19
АС401-79 48 22 19
АС403-39 51 25 22
АС403-59 51 25 22
АС403-79 51 25 22
АС1001-79 48 22 19
Maximum amperage ratings for the various voltagesNote - all 480v and 600v rated air curtains require separate 3ph wiring to heating elements, and 208/220v 1ph to motors
Control Panel included with every air curtain.Control Panel incorporate a thermostat, 3 speed control and2 heat settings, and can be connected through a central building control system or door activated switches and sensors.
-
9
Air Flow
AVAILABLE OPTIONS
MODELS
AC100
208V/240V/1/60HZ
SERIES
AVAILABLE VOLTAGES
OVERVIEW
Electric Heated
Series 100 – compact stylish unit for use in smaller applications. A lower velocity unit with a 5 kW heater designed with built-in controls for ease of installation and operation. Ideal as a unit space heater, an air curtain over a drive through window, or for single doors where wind factors or large temperature changes are not a factor.
Electric Heated
31E3, 31E4, 31Е5
GENERAL CHARACTERISTICS
MODEL 31E4
Voltage V/PH/Hz 208/1/60
Heat Output kBTU/h
kW
1 .32
3.6
Air Volume cfm
m /h³
295
500
ft
m
7.2
2.2
Тemperature rise °F
°C
39.6
22
Length ft
mm
Dimensions in
mm
30 x x.9 7.5 8.9
800 x 95 x 2351
Weight lb
kg
23
10.5
Motor Input hp
W
0.075
55
Max. Current A 18
Sound Level at 5 m (distance) dB(A) 45
31E3
9.2
2.7
28 8.
16
13
31E5
16.3
4.8
50.4
28
24
2.6
785
Мах. Door Height
Air Flow
1
1,5
2 1,4
1,6
2,0
4,5
2013-2014 SERIES:AIR CURTAINS / AIR DOORS NEW!
Air Flow
-
2013-2014 Series: Air Curtains / Air Doors
Electric Heated | Water Heated | Ambient (Unheated)
208V/240V/1/60HZ, 208V/240V/3/60HZ, 480V/3/60HZ, 600V/3/60HZ
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
OVERVIEW
Electric Heated Ambient (Unheated)
Water Heated
11
Air Flow
Air Flow
AC200
Series 200 – Lower velocity units rated for installation up to a maximum 8’ (2.5m). Designed primarily for single doors or smaller vestibules. Also ideal for drive through windows where a higher velocity may be required when mounting the unit farther from the window. Heat output 5 to 11 kW.
Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.Can be operated through door switches and sensors. Each сontrol panel can operate:6 – 39E, 39W, 39A4 – 59E, 59W, 59A
39E5, 39E8, 59E8, 59E11 | 39W8, 59W13 | 39A, 59A
AC200
GENERAL CHARACTERISTICS
MODEL 39E5 39E8 59E8 59E11
Voltage V/PH/Hz 208/3/60
Heat Output kBTU/hkW
18
5.3
27.3
8.0
27.3
8.0
36.5
10.7
Air Volume cfmm /h³
883
1 050
883
1 050
10 06
1 008
10 06
1 008
Max. Door Height ftm
8.2
2.5
Тemperature rise °F°C
18.9
10.5
28.8
16
23.4
13
32.4
18
Length ftmm
3.3
1000
3.3
1000
4.9
1500
4.9
1500
Dimensions inmm
40 11 9x x
1015 280 230x x
59.6 1 9x 1 x
1515 280 230x x
Weight lbkg
33.1
15
33.1
15
46.4
21
46.4
21
Motor Input hpW
0.19
1 04
0.19
1 04
0.217
160
0.217
160
Max. Current A 17 24 24 32
Sound Level at 5 m (distance) dB(A) 52 52 53 53Air Flow
THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)
MODEL 39W8
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
23.9
7.0
25.6
7.5
27.0
7.9
27.3
8.0
21.5
6.3
6.8
2.0
Air Тemperature rise °F
°C
36
20
39.6
22
41.4
23
41.4
23
32.4
18
9
5
Water Flow USGPH
l/s
19.02
0.02
28.53
0.03
57.07
0.06
85.60
0.09
76.09
0.08
28.53
0.03
MODEL 59W13
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
51.9
15.2
49.8
14.6
46.8
13.7
44.4
13
36.9
10.8
19.1
5.6
Air Тemperature rise °F
°C
54
30
50.4
28
46.8
26
46.8
26
37.8
21
19.8
11
Water Flow USGPH
l/s
37.56
0.05
66.58
0.07
104.68
0.11
142.67
0.15
142.67
0.15
66.58
0.07
* Based on inlet and outlet water temperatures of 203°F/158°F (95°C/70°C)
GENERAL CHARACTERISTICS
MODEL 39W8 59W13
Voltage V/PH/Hz 208/1/60
Heat Output kBTU/h
kW
27.3
8.0
44.4
13.0
Air Volume cfm
m /h³
766
1500
1060
1800
Мах. Door Height ft
m
8.2
2.5
Тemperature rise∗ °F°C
41.4
23
46.8
26
Length ft
mm
3.3
1000
4.9
1500
Dimensions in
mm
39.9 x 11. x 9.11
1014 x 282 x 229
59.6 x 11. x 9.11
1514 x 282 x 229
Weight lb
kg
35
16
49.6
22.5
Motor Input hp
W
0.19
140
0.212
156
Max. Current A 0.7 0,75
Sound Level at 5 m (distance) dB(A) 51 52
GENERAL CHARACTERISTICS
MODEL 39A 59A
Voltage V/PH/Hz 208/1/60
Air Volume cfm
m /h³
883
1 005
1060
1 008
Мах. Door Height ft
m
8.2
2.5
Length ft
mm
3.3
1000
4.9
1500
Dimensions in
mm
39.9 1.1 9.1x 1 x
1014 281 231x x
59.6 1.1 9.1x 1 x
1514 281 231x x
Weight lb
kg
31
14
42
19
Motor Input hp
W
0.19
1 04
0.212
156
Max. Current A 0.7 0.75
Sound Level at 5 m (distance) dB(A) 51 52
-
2013-2014 Series: Air Curtains / Air Doors
Electric Heated | Water Heated | Ambient (Unheated)
208V/240V/1/60HZ, 208V/240V/3/60HZ, 480V/3/60HZ, 600V/3/60HZ
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
OVERVIEW
Electric Heated Ambient (Unheated)
Water Heated
13
Air Flow
Air Flow
AC300
Series 300 - Elegant in design for retail and commercial applications. Designed for use up to a maximum 11 feet (3.5m) in height, this series is designed for mostly pedestrian entrances or smaller garage door installations. Available in lengths of 39” for a single door, 59” for a double swinging door, or 79” to cover a single double sliding door, or in tandem for larger installations. Available heating for the various lengths from 5 to 28 kW.
Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.Can be operated through door switches and sensors. Each control panel can operate:4 – 39E, 39W, 39A2 – 59E, 79E, 59W, 79W, 79A
39E5, 39E8, 59E8, 59E11, 59E13, 79E11, 79E16, 79E21 | 39W12, 59W20, 79W28 | 39A, 59A, 79A
AC300
8,8
4,5
3,2
2,6
2,2
GENERAL CHARACTERISTICS
39E5 39E8 59E8 59E11 59E13 79E11 79E16 79E21
208/3/60 208/3/60 208/3/60
18
5.3
27.3
8.0
27.3
8.0
36.5
10.7
45.7
13.4
36.5
10.7
54.9
16.1
73.4
21.5
1030
1750
1030
1750
1590
2700
1590
2700
1590
2700
2091
3550
2091
3550
2091
3550
11.5
3.5
11.5
3.5
11.5
3.5
16.2
9
25.2
14
16.2
9
21.6
12
27
15
16.2
9
25.2
14
32.4
18
3.3
1000
3.3
1000
4.9
1500
4.9
1500
4.9
1500
6.6
2000
6.6
2000
6.6
2000
40 x x.5 12.3 10.7
1030 13 271x 3 x
60.2 12.3 10.7x x
1530 13 271x 3 x
77.7 12.3 10.7x x
1974 13 271x 3 x
42
19
42
19
65
29.5
65
29.5
65
29.5
79.5
36
79.5
36
79.5
36
0.312
230
0.312
230
0.625
460
0.625
460
0.625
460
0.625
460
0.625
460
0.625
460
17 24 25 33 40 33 48 78.5
54 54 54 54 54 57 57
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Max. Door Height ft
m
Тemperature rise °F
°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
8,3
4,2
3,0
2,5
2,1
3
4
2
1
0
THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)
MODEL 39W12
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
26.3
7.7
36.5
10.7
38.6
11.3
39.2
11.5
31.4
9.2
10.6
3.1
Air Тemperature rise °F
°C
28.8
16
41.4
23
43.2
24
43.2
24
34.2
19
10.8
6
Water Flow USGPH
l/s
28.53
0.03
47.56
0.05
85.60
0.09
123.64
0.13
114.13
0.12
38.04
0.04
MODEL 59W20
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
76.8
22.5
72.7
21.3
67.6
19.8
54.6
16.0
27.3
8.0
Air Тemperature rise °F
°C
55.8
31
52.2
29
46.8
26
39.6
22
36
20
Water Flow USGPHl/s
76.09
0.08
95.11
0.1
221/158
105/70
68.9
20.2
48.6
27
152.18
0.16
188.74
0.20
199.74
0.21
104.62
0.11
GENERAL CHARACTERISTICS
39W12 59W20 79W28
208/1/60
39.2
11.5
67.6
19.8
93.5
27.4
972
1 065
1472
2 005
1943
3 003
11.5
3.5
43.2
24
46.8
26
48.6
27
3.3
1000
4.9
1500
6.6
2000
42
19
66.2
30
82
36
0.312
230
0.625
460
0.625
4 06
1.1 2.2 2.2
52 53 56
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Мах. Door Height ft
m
Тemperature rise∗ °F°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
40.5 12.3 10.5x x
1030 1 268x 3 3 x
60.2 12.3 10.5x x
1530 1 268x 3 3 x
77.7 12.3 10.5x x
1974 1 268x 3 3 x
MODEL 79W28
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
111.9
32.8
105.1
30.8
96.9
28.4
93.5
27.4
75.4
22.1
41.6
12.2
Air Тemperature rise °F
°C
61.2
34
55.8
31
50.4
28
48.6
27
41.4
23
23.4
13
Water Flow USGPHl/s
104.62
0.11
133.16
0.14
209.25
0.22
285.34
0.30
285.34
0.30
152.18
0.16
GENERAL CHARACTERISTICS
39A 59A 79A
208/1/60
1030
1 075
1 059
2 007
2091
3 055
11.5
3.5
3.3
1000
4.9
1500
6.6
2000
26.5
12
53
24
88
66.5
0.312
230
0.625
460
0.625
4 06
1.1 2.2 2.2
52 53 56
MODEL
Voltage V/PH/Hz
Air Volume cfm
m /h³
Мах. Door Height ft
m
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
40.5 12.3 10.7x x
1030 1 271x 3 3 x
60.2 12.3 10.7x x
1530 1 271x 3 3 x
77.7 12.3 10.7x x
1974 1 271x 3 3 x
-
2013-2014 Series: Air Curtains / Air Doors
208V/240V/1/60HZ, 208V/240V/3/60HZ, 480V/3/60HZ, 600V/3/60HZ
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
15
Air Flow
Air Flow
AC301
Water Heated
Electric Heated
Series 301 - Designed specifically for installations into standard drop ceilings of up to 11’ (3.5m) in height, but can be utilized wherever a flush mounted air curtain will be required for commercial, retail or institutional applications. Can be secured directly to structure from above or suspended on chains or threaded rods. Heat output available from 5 to 28 kW.
Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.Can be operated through door switches and sensors. Each control panel can control:4 – 39E, 39W2 – 79E, 79W
39E5, 39E8, 79E11, 79E16 | 39W11, 79W28
Electric Heated | Water Heated
AC301
OVERVIEW
0 5,
1
1 5,
2
2 5,
3
5 5,
3 3,
2 7,
2 3,
2 1,
1 9,
0 5,
1
1 5,
2
2 5,
3
4 9,
2 8,
2 3,
1 9,
1 8,
1 6,
GENERAL CHARACTERISTICS
39E5 39E8 79E11 79E16
208/3/60
18
5.3
27.3
8.0
36.5
10.7
54.9
16.1
1030
17 05
10 03
17 05
2091
3 055
2091
3 055
11.5
3.5
16.2
9
25.2
14
16.2
9
25.2
14
3.3
1000
3.3
1000
6.6
2000
6.6
2000
43.5 7.3 1.8х 1 x 1
1105 4 0х 4 0 x 3 0
80.7 7.3 1.8х 1 x 1
2050 4 0х 4 0 x 3 0
66.2
30
66.2
30
119.2
54
119.2
54
0.312
230
0.312
230
0.625
460
0.625
460
17 24 33 48
53 53 57 57
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Max. Door Height ft
m
Тemperature rise °F
°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
THERMAL CHARACTERISTICS (Thermal characteristics at room ambient temperature 59°F (15°C) and maximum airow)
MODEL 39W11
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
26.28
7.7
36.52
10.7
38.57
11.3
39.25
11.5
31.40
9. 2
10.58
3.1
Air Тemperature rise °F
°C
28.8
16
41.4
23
43.2
24
43.2
24
34.2
19
10.8
6
Water Flow USGPH
l/s
28.53
0.03
47.56
0.05
85.60
0.09
123.65
0.13
114.13
0.12
38.04
0.04
MODEL 79W28
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
111.95
32.8
105.12
30.8
96.93
28.4
93.52
27.4
75.43
22.1
41.64
12.2
Air Тemperature rise °F
°C
61.2
34
55.8
31
50.4
28
48.6
27
41.4
23
23.4
13
Water Flow USGPHl/s
104.62
0.11
133.16
0.14
209.25
0.22
285.34
0.30
285.34
0.30
152.18
0.16
* For water heaters this is 203°F/158°F (95°C/70°C) hot water
GENERAL CHARACTERISTICS
39W11 79W28
208/1/60
39.2
11.5
93.5
27.4
972
1 065
1943
3300
11.5
3.5
43.2
24
48.6
27
3.3
1000
6.6
2000
70.6
34
132.4
60
0.312
230
0.625
460
1.1 2.2
53
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Мах. Door Height ft
m
Тemperature rise∗ °F°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
43.5 7.3 1.8х 1 x 1
1105 4 0х 4 0 x 3 0
80.7 7.3 1.8х 1 x 1
2050 4 0х 4 0 x 3 0
Air Flow
Air Flow
-
2013-2014 Series: Air Curtains / Air Doors
Electric Heated | Water Heated | Ambient (Unheated)
208V/240V/1/60HZ, 208V/240V/3/60HZ, 480V/3/60HZ, 600V/3/60HZ
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
OVERVIEW
Electric Heated Ambient (Unheated)
17
Air Flow
Air Flow
AC400
Water Heated
Series 400 – Higher output units for high pedestrian traffic areas, larger volume buildings i.e. malls, recreational facilities, warehouse bay doors of up to 16’ (5m) etc. Powerful unit available heated (electric or water) or unheated. Versatile in many different commercial or industrial applications. Heating available in electric from 11 to 32 kW and water heated to 47 kW.
39E8, 39E11, 39E16, 59E11, 59E16, 59E21, 79E16, 79E21, 79E32 | 39W20, 59W32, 79W47 | 39A, 59A, 79A
AC400
Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.Can be operated through door switches and sensors. Each control panel can operate: 1 – 39E, 59E, 79E, 39W, 59W, 79W
12 3,
6,7
4,7
3,9
3,4
3,0
THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)
MODEL 39W20
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
58.4
17.1
62.5
18.3
62.5
19.1
66.2
19.4
52.6
15.4
16.5
4.9
Air Тemperature rise °F
°C
63
35
64.8
36
66.6
37
66.6
37
59.4
33
37.8
21
Water Flow USGPH
l/s
57
0.06
76.1
0.08
142.7
0.15
200
0.21
200
0.21
57
0.06
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
122.9
36
118.4
34.7
111.9
32.8
109.2
32
88.1
25.8
45.1
13.2
52.2
29
50.4
28
48.6
27
46.8
26
37.8
21
1 .89
11
123.65
0.13
152.18
0.16
247.29
0.26
332.89
0.35
332.89
0.35
171.20
0.18
MODEL 59W32
Water Temperature at Inlet/Outlet °F
°C
Heat Output kBTU/h
kW
Air Тemperature rise °F
°C
Water Flow USGPHl/s
MODEL 79W47
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
195.2
57.2
182.9
53.6
167.9
49.2
161.8
47.4
130.7
38.3
73.0
21.4
Air Тemperature rise °F
°C
59.4
33
55.8
31
48.6
27
48.6
27
39.6
22
21.6
12
Water Flow USGPHl/s
190.22
0.20
237.78
0.25
361.43
0.38
494.58
0.52
494.58
0.52
275.83
0.29
GENERAL CHARACTERISTICS
59W32 79W47
208/1/60
109.2
32.0
161.8
47.4
2002
3 004
3062
5 002
16.4
5.0
46.8
26
48.6
27
4.9
1500
6.6
2000
91.6
41.5
117
53
0.87
640
1.224
900
3 4.4
64 65
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Мах. Door Height ft
m
Тemperature rise∗ °F°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
59.6 11.7 15.5x x
1514 298 394x x
39W20
68.3
20
1531
2 006
66.6
37
3.3
1000
68.5
31
0.612
450
2.2
64
41.1 11.7 15.5x x
1044 298 394x x
7 x x9.5 11.7 15.5
2020 298 394x x
GENERAL CHARACTERISTICS
208/1/60
16.4
5.0
MODEL
Voltage V/PH/Hz
Air Volume cfm
m /h³
Мах. Door Height ft
m
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
39A
1531
2600
3.3
1 000
61.8
28
0.612
450
2.2
64
41.1 11.7 15.5x x
1044 298 394x x
79A
3062
5 002
6.6
2000
101.5
46
1.224
900
4.4
65
79.5 11.7 15.5x x
2020 298 394x x
59A
2002
3 004
4.9
1500
78.3
35.5
0.87
640
3
64
59.6 11.7 15.5x x
1514 298 394x x
12 3,
6,7
4,7
3,9
3,4
3,0
GENERAL CHARACTERISTICS
59E11 59E16 59E21 79E16 79E21 79E32
208/ /603 208/ /603
36.5
10.7
54.9
16.1
73.4
21.5
54.9
16.1
73.4
21.5
109.9
32.2
2002
3400
2002
3400
2002
3400
3062
5200
3062
5200
3062
5200
16.4
5.0
16.4
5.0
17.1
9.5
25.2
14
33.3
18.5
16.2
9
21.6
12
33.3
18.5
4.9
1500
6.6
2000
59.6 11.7 15.5x x
1514 298 394x x
79.5 1.7 15.5x 1 x
2020 298 394x x
90.5
41
126
55
0.87
640
1.224
900
65
39E11
208/ /603
37.5
11
1531
2 006
11.5
3.5
22.5
12.5
3.3
1000
41.1 11.7 15.5x x
1044 298 394x x
77.16
35
0.612
450
34
60
39E16
54.9
16.1
33.3
18.5
63.2
39E8
27.3
8
16.2
9
25
66
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Max. Door Height ft
m
Тemperature rise °F
°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
2 006 2 006
1531 1531
34.5 48.2 63.2 50 65 95
-
2013-2014 Series: Air Curtains / Air Doors
Electric Heated | Water Heated | Ambient (Unheated)
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
OVERVIEW
Ambient (Unheated)
Water Heated
19
208V/240V/3/60HZ, 480V/3/60HZ, 600V/3/60HZ
Air Flow
Air Flow
AC401
Electric Heated
59E11, 59E16, 59E21, 79E16, 79E21, 79E32 | 59W32, 79W47 | 59A, 79A
AC401
Series 401 – Designed specifically for high humidity locations i.e. car, truck or bus wash bays, industrial and production drying facilities etc. High output unit for installations of up to 16’ (5m), available in galvanized steel or stainless steel finishes depending on requirements. Available heating options both electric or hot water up to 32 kW.The standard control panels supplied with these units, are not rated for installation into environments that are wet or have high humidity. Control panels will require, either being installed into a separate dry location, or into a locally supplied and approved /certified sealed enclosure before operating air curtains.
14
7,3
5,2
4,2
3,7
3,3
GENERAL CHARACTERISTICS
59E11 59E16 59E21 79E16 79E21 79E32
208/3/60 208/3/60
36.5
10.7
54.9
16.1
73.4
21.5
36.5
10.7
73.4
21.5
109.9
32.2
2237
3800
2237
3800
2237
3800
3500
6000
3500
6000
3500
6000
16.4
5.0
16.4
5.0
15.3
8.5
22.5
12.5
29.7
16.5
25.2
14
46.8
27
73.8
41
4.9
1500
4.9
1500
4.9
1500
6.6
2000
6.6
2000
6.6
2000
58.7 x 21.8 x 20.2
1495 555 5x x 51
79. x 21.8x 20.25
202 x 55 x 510 5 5
128
58
128
58
128
58
168
76
168
76
168
76
0.735
540
0.735
540
0.735
540
1.088
800
1.088
800
1.088
800
3 .54 4 .8 2 78.5 46.5 61.5 92.2
65 65 65 66 66
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Max. Door Height ft
m
Тemperature rise °F
°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
Motor Input
13,5
7,0
5,0
4,0
3,5
3,2 THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)
MODEL 59W32
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
122.9
36
118.4
34.7
111.9
32.8
109.2
32
88.1
25.8
45.1
13.2
Air Тemperature rise °F
°C
52.5
29
50.4
28
48.6
27
46.8
26
37.8
21
19.8
11
Water Flow USGPH
l/s
123.65
0.13
152.18
0.16
247.29
0.26
332.89
0.35
332.89
0.35
171.20
0.18
MODEL 79W47
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
195.2
57.2
182.9
53.6
167.9
49.2
161.8
47.4
130.7
38.3
73.0
21.4
Air Тemperature rise °F
°C
59.4
33
55.8
31
48.6
27
48.6
27
39.6
22
21.6
12
Water Flow USGPHl/s
190.22
0.20
237.78
0.25
361.43
0.38
49 .589
0.52
494.58
0.52
275.83
0.29
GENERAL CHARACTERISTICS
59W32 79W47
208/3/60
109.2
32.0
161.8
47.4
2120
3600
2950
5000
16.4
5.0
46.8
26
48.6
27
4.9
1500
6.6
2000
58.7 1.8x 2 x 20.2
1 x 5 x 5495 55 15
79. x 2 x 20..5 1.8 2
202 x 5 x 50 55 15
132.5
60
168
76
0.735
540
1.088
800
0.9 1.3
60 62
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Мах. Door Height ft
m
Тemperature rise∗ °F°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
GENERAL CHARACTERISTICS
59A 79A
208/3/60
2350
4000
3500
6000
16.4
5.0
4.9
1500
6.6
2000
119
54
154.5
70
0.735
540
1.088
800
0.9 1.3
60 62
MODEL
Voltage V/PH/Hz
Air Volume cfm
m /h³
Мах. Door Height ft
m
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
58.7 1.8x 2 x 20.2
1 x 5 x 5495 55 15
79. x 2 x 20..5 1.8 2
202 x 5 x 50 55 15
-
2013-2014 Series: Air Curtains / Air Doors
Electric Heated | Water Heated | Ambient (Unheated)
208V/240V/1/60HZ, 208V/240V/3/60HZ, 480V/3/60HZ, 600V/3/60HZ
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
OVERVIEW
Electric Heated Ambient (Unheated)
Water Heated
21
Air Flow
Air Flow
AC403
Series 403 – Surface mount unit for many types of applications, commercial, industrial or institutional wherever higher output is required for mounting up to 16’ (5m). Available in 39”, 59” and 79” lengths, in coloured finish or decorative with polished stainless steel and lighting. Heating options available to 32kW electric, and 47 kW in hot water heated.
39E8, 39E11, 39E16, 59E11, 59E16, 59E21, 79E16, 79E21, 79E32
AC403
6,31
3
2 4,5
3,7
6,31
3
2 4,5
3,7
GENERAL CHARACTERISTICS
27.3
8
MODEL
Voltage V/PH/Hz
Heat Output kBTU/hkW
Air Volume cfmm /h³
Max. Door Height ftm
Тemperature rise °F°C
Length ftmm
Dimensions inmm
Weight lbkg
Motor Input hpW
Max. Current A
Sound Level at 5 m (distance) dB(A)
39E8
18
10
25
37.5
11
39E11
1413
2 004
23.4
13
3.3
1000
44.5 x x23.6 15.2
1130 x х600 385
0.612
450
34.5
60
106
48
54.9
16.1
39E16
36
20
48.5
3 .56
10.7
59E11
18
10
34.5
54.9
16.1
59E16
208/3/60
1885
3200
27
15
4.9
1500
63.4 23.6 15.2x x
1 х х610 600 385
1.224
900
48.2
150
68
66 2.
19
59E21
16
5.0
28.8
16
63.2
54.9
16.1
79E16
18
10
50
61
73.4
21.5
79E21
2827
4800
23.4
13
6.56
2000
83.8 23.6 15.2x x
2 х х130 600 385
63.2
195
88
109.9
32.2
79E32
36
20
0.87
640
63
Control panel included with every air curtain.Complete with 3-speed control, Thermostat and 2 heat settings.Can be operated through door switches and sensors.Each control panel can operate:1-39E, 59E, 79E
THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airflow)
MODEL 3 209W
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
58.4
17.1
62.5
19.1
66.2
19.4
52.6
15.4
16.5
4.9
Air Тemperature rise °F
°C
63
35
66.6
37
66.6
37
59.4
33
37.8
21
Water Flow USGPH
l/s
57
0.06
142.7
0.15
200
0.21
200
0.21
57
0.06
MODEL 5 329W
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
122.9
36
111.9
32.8
109.2
32
88.1
25.8
45.1
13.2
Air Тemperature rise °F
°C
52.2
29
48.6
27
46.8
26
37.8
21
19.8
11
Water Flow USGPHl/s
123.65
0.13
247.29
0.26
332.89
0.35
332.89
0.35
171.2
0.18
GENERAL CHARACTERISTICS
39W20 59W32
208/1/60
68 24.
20
109.2
32
1178
2000
2120
3600
16.4
5
66 6.
37
46.8
26
3.3
1 000
4.9
1500
44.5 23.6 15.1x x
1 х x130 600 385
63.4 23.6 15.1x x
1610 600 385x x
77.16
45
95
59
0.544
400
0.721
530
2.1 2.8
64 64
* Based on inlet and outlet water temperatures of 203°F/158°F (95°C/70°C)
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Мах. Door Height ft
m
Тemperature rise∗ °F°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
79W47
161.8
47.7
2950
5000
48.6
27
6.6
2000
83.9 23.6 15.1x x
2 x x130 600 385
126
73
1.088
800
4.2
65
MODEL 7 479W
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
195.2
57.2
167.9
49.2
161.8
47.4
130.7
38.3
73
21.4
Air Тemperature rise °F
°C
59.4
33
48.6
27
48.6
27
39.6
22
21.6
12
Water Flow USGPHl/s
190.22
0.2
361.43
0.38
494.58
0.52
494.58
0.52
275.83
0.29
266/158
130/70
62.5
18.3
64.8
36
76.1
0.08
266/158
130/70
118.4
34.7
50.4
28
152.18
0.16
266/158
130/70
182.9
53.6
55.8
31
237.78
0.25
GENERAL CHARACTERISTICS
39A 79A
1472
2500
3.3
1 000
6.6
2000
77.16
45
126
73
0.544
400
1.088
800
2.1 4.2
63 65
MODEL
Voltage V/PH/Hz
Air Volume cfm
m /h³
Мах. Door Height ft
m
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
2950
5000
44.5 23.6 15.1x x
1 х x130 600 385
83 9 23.6 15.1. x x
2 x x130 600 385
59A
2120
3600
4.9
1500
95
59
0.721
530
2.8
64
63.4 23.6 15.1x x
1 х x610 600 385
208/1/60
16.4
5
-
2013-2014 Series: Air Curtains / Air Doors
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
23
Air Flow
208V/240V/1/60HZ
AC500
OVERVIEW
Series 500 – For larger industrial, warehouse and distribution centers, for installation of up to 19’(6m) openings. Hot water heated (up to 107 kW) this unit can be mounted either horizontally or vertically, designed with the nozzle’s angled at 20° to the exterior to compensate for the exterior air pressures on the air stream across the opening.
Control panel included with every air curtain. Complete with - 3 speed control,Thermostat and 2 heat settings.Can be operated through door switches and sensors. Each control panel can control:10 – 59W, 79W
59W71, 79W107
Water Heated
AC500
H, mV, m/s
12
5,6
3,9
3,2
200
THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)
MODEL 59W71
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
388.4
8 .54
271.7
79.6
250.5
73.4
242.3
71.0
195.2
57.2
104.4
30.6
Air Тemperature rise °F
°C
68.4
38
64.8
36
59.4
33
57.6
32
46.8
26
25.2
14
Water Flow USGPH
l/s
275.83
0.29
342.40
0.36
542.14
0.57
732.36
0.77
732.36
0.77
389.96
0.41
MODEL 79W107
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
453.9
13 .03
4 3.2 2
12 .04
382.2
11 .02
365.2
107.0
295.2
86.5
167.9
49.2
Air Тemperature rise °F
°C
72
40
68.4
38
61.2
34
57.6
32
46.8
26
27
15
Water Flow USGPHl/s
473.52
0.46
542.14
0.57
836.99
0.88
11 .812 1
1.17
11 .812 1
1.17
627.74
0.66
GENERAL CHARACTERISTICS
59W71 79W107
208/1/60
242.3
71.0
365 2.
107.0
3770
6400
5650
9600
19.7
6.0
57.6
32
57.6
32
4.9
1500
6.6
2000
62.6 30.94 22.4x x
15 х 7 x90 86 569
82.28 94 2.4x 30. x 2
20 x 7 x90 86 569
243
110
318
144
2.653
1 095
3.946
2 009
9.5 14.0
65 67
* Based on inlet and outlet water temperatures of 203°F/158°F (95°C/70°C)
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Мах. Door Height ft
m
Тemperature rise∗ °F°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
Water Heated
Air Flow
-
2013-2014 Series: Air Curtains / Air Doors
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
Ambient (Unheated)
Water Heated
25
Air Flow
208V/240V/3/60HZ
Air Flow
AC700
Series 700 – Designed for openings up to 23’ and where higher wind and temperature variations are a factor. This axial fan equipped air curtain is available ambient or water heated (up to 113 kW) and is available 59’ or 79”, to be installed in tandem to make up any sized openings and required air outputs.
59W79, 59W113 | 59A, 79A
Water Heated | Ambient (Unheated)
AC700
OVERVIEW
Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.Can be operated through door switches and sensors. Each control panel can control:10 – 59W, 59A, 79W, 59A
THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)
MODEL 59W79
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
305.5
89.5
290.8
85.2
274.1
80.3
267.9
78.5
184.3
54.0
112.6
33.0
Air Тemperature rise °F
°C
48.6
27
45
25
43.2
24
41.4
23
34.2
19
18
10
Water Flow USGPH
l/s
294.85
0.31
370.94
0.39
599.21
0.63
817.97
0.86
817.97
0.86
418.49
0.44
MODEL 79W113
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
460.7
135.0
433.4
127.0
399.3
117.0
385.7
113
310.2
90.9
173.4
50.8
Air Тemperature rise °F
°C
52.2
29
48.6
27
45
25
43.2
24
36
20
19.8
11
Water Flow USGPHl/s
447.03
0.47
551.65
0.58
865.52
0.91
1169.88
1.23
1179.39
1.24
646.76
0.68
GENERAL CHARACTERISTICS
59W79 79W113
208/3/60
268.0
78.5
385.6
113.0
5770
9800
7950
13500
23.0
7.0
41.4
23
43.2
24
4.9
1500
6.6
2000
60 7.8x 2 x 25.7
152 х 7 x 655 05 5
79. x x 25.79 27.8
20 x 7 x 6530 05 5
188
85
265
120
1.905
1400
2.857
2100
2.3 3.4
65 67
* Based on inlet and outlet water temperatures of 203°F/158°F (95°C/70°C)
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Мах. Door Height ft
m
Тemperature rise∗ °F°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
GENERAL CHARACTERISTICS
59A 79A
208/3/60
6772
15001
23.0
7.0
4.9
1500
6.6
2000
153.5
69.5
227
103
1.77
1 003
2.857
2100
6.5 3.4
66 68
MODEL
Voltage V/PH/Hz
Air Volume cfm
m /h³
Мах. Door Height ft
m
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
8834
50001
60 7.8x 2 x 25.7
152 х 7 x 655 05 5
79. x x 25.79 27.8
20 x 7 x 6530 05 5
13,5
6,3
4,8
4,1
-
2013-2014 Series: Air Curtains / Air Doors
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
27
Air Flow
208V/240V/3/60HZ
AC800
OVERVIEW
800-31W220 | 800-31A
Water Heated | Ambient (Unheated)
AC800
Control panel included with every air curtain.Complete with - 3 speed control, Thermostat and 2 heat settings. Can be operated through door switches and sensors. Each control panel can control:10 – AC801 water or ambient.
80 - W2200 31 80 - А0 31
208/3/60
2,1
4
67
GENERAL CHARACTERISTICS
MODEL
Voltage
Air Volume
Max. Door Height
Dimensions
Nozzle Dimensions
Weight
Motor Input
Max. Current
Sound Level at 5 m
V/PH/Hz
A
db(A)
4
67
5800/ 8700/ 11550m /h³ 6700/ 10000/ 13500
15m 1549.21ft 49.21
30.3 9.2 55.3х 7 х
mm 7 x 2 x70 025 1405in
470 х 575mm 470 х 57518.5 x 22.64in 18.5 x 22.64
140kg 140308.6lb 308.6
KW 2,12.816hp 2.816
3416/ 5124/ 6802cfm 3946/ 5890/ 7950
Water heated Ambient (Unheated)
30.3 9.2 55.3х 7 х
7 x 2 x70 025 1405
THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)
Airow 11550 m /h³
Water Temperature at Inlet/Outlet °F°C
°F
°C
°F
°C
°F
°C
°F
°C
°F
°C
302/158
150/70
55.8
31
302/158
150/70
61.2
34
266/158
130/70
57.6
32
221/158
105/70
54
30
203/158
95/70
50.4
28
176/140
80/60
41.4
23
140/104
60/40
kW 103 96 89 85 69 39
kBTU/h 351.4 327.6 303.7 290 235.4 133.1
23.4
13
l/s 0,36 0,44 0,69 0,93 0,94 0,52USGPH 342.4 418.5 656.27 884.54 894.06 494.6
302/158
150/70
72
40
266/158
130/70
66.6
37
221/158
105/70
61.2
34
203/158
95/70
57.6
32
176/140
80/60
46.8
26
140/104
60/40
kW 78 74 68 65 52 29
kBTU/h 266.1 252.5 232 221.8 177.4 98.95
25.2
14
l/s 0,27 0,34 0,53 0,71 0,71 0,39
USGPH 256.8 323.4 504.1 675.3 675.3 370.94
266/158
130/70
52.2
29
221/158
105/70
48.6
27
203/158
95/70
46.8
26
176/140
80/60
41.4
23
140/104
60/40
kW 123 115 106 103 83 46
kBTU/h 419.7 392.4 361.7 351.4 283.2 157
21.6
12
l/s 0,42 0,53 0,83 1,12 1,12 0,62
USGPH 399,43 504.1 789.4 1065.26 1065.26 589.7
Heat Output
Air Тemperature rise
Water Flow
Airow 8700 m /h³
Water Temperature at Inlet/Outlet
Heat Output
Air Тemperature rise
Water Flow
Airow 5800 m /h³
Water Temperature at Inlet/Outlet
Heat Output
Air Тemperature rise
Water Flow
AC800-31W220
Air Flow
Series 800 – These extra high output units were specifically designed to be installed in tandem across large door openings. Because doors of this size are not standard, these units are installed in multiples to make up any sized opening, without the need to custom design one single air curtain for every application. They are available in two different models, with outputs rated for openings up to 50’ (15 m). Available water heated or ambient.
-
2013-2014 Series: Air Curtains / Air Doors
Electric Heated | Water Heated | Ambient (Unheated)
208V/240V/1/60HZ, 208V/240V/3/60HZ, 480V/3/60HZ, 600V/3/60HZ
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
OVERVIEW
Electric Heated Ambient (Unheated)
Water Heated
29
Air Flow
Air Flow
AC1000
79E21, 79E32, 79E43, 39E11, 39E16, 39E21 | 39W20, 79W50 | 79A
AC1000
1
3
2
6,3
4,5
3,7
1
3
2
6,3
4,5
3,7
Series 1000 – Higher powered decorative model, available with lighting. Suitable for, retail or condominium environments, for installation up to 11`(3.5 m) in height. Available also in polished or brushed finish stainless steel. Combination of an energy saving air curtain, and in addition can provide illumination in the lobby, entranceway or vestibule. Can be flush mounted or suspended.
Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.Can be operated through door switches and sensors. Each control panel can control:1 – 79W, 79A, 79E.
GENERAL CHARACTERISTICS
79E21 79E32 79E43
208/3/60
73.4
21.5
109.9
32.2
146.8
43.0
3415
5800
11.5
3.5
19.8
11
28.8
16
37.8
21
6.6
2000
84.2 23.1 14.2x x
2140 740 365x x
161
73
1.224
900
65 95 125
63
MODEL
Voltage V/PH/Hz
Heat Output kBTU/hkW
Air Volume cfmm /h³
Max. Door Height ftm
Тemperature rise °F°C
Length ftmm
Dimensions inmm
Weight lbkg
Motor Input hpW
Max. Current A
Sound Level at 5 m (distance) dB(A)
3 19E 1 3 169E 3 219E
208/3/60
36.5
10.7
54.9
16.1
73.4
21.5
1707
2900
11.5
3.5
19.8
11
28.8
16
37.8
21
3.3
1000
44.9 29.0 14.2x x
1140 737 361x x
99
45
0.612
450
34.5 48.2 63.2
60
* Based on inlet and outlet water temperatures of 203°F/158°F (95°C/70°C)
THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)
MODEL 39 20W
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
64.5
18.9
67.2
19.7
69.3
20.3
70
20.5
55.6
16.3
17
5
Air Тemperature rise °F
°C
37.8
21
37.8
21
39.6
22
39.6
22
32.4
18
9
5
Water Flow USGPHl/s
61.8
0.65
84.6
0.089
152.2
0.16
209.2
0.22
209.2
0.22
62.8
0.066
GENERAL CHARACTERISTICS
3 29W 0
70
20.5
1590
2700
11 5.
3.5
39.6
22
3.3
1000
44.9 29 14.2x x
1140 737 361x x
99
45
0.612
450
4
57
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Мах. Door Height ft
m
Тemperature rise ∗ °F°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
79W50
208/1/60
172
50.4
3230
5500
55.8
31
6.6
2000
84.2 23.1 14.2x x
2140 740 365x x
161
73
1.224
900
8
60
MODEL 79W50
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
206.1
60.4
193.2
56.6
178.2
52.2
172.0
50.4
138.6
40.6
76.5
22.4
Air Тemperature rise °F
°C
66.6
37
63
35
57.6
32
55.8
31
45
25
25.2
14
Water Flow USGPHl/s
190.22
0.20
237.78
0.25
370.94
0.39
504.10
0.53
513.61
0.54
285.34
0.30
GENERAL CHARACTERISTICS
79AMODEL
Voltage V/PH/Hz
39A
208/1/60
3534
6000
6.6
2000
84.2 23.1 14.2x x
2140 740 365x x
152.3
69
1.224
900
8
60
Air Volume cfm
m /h³
Мах. Door Height ft
m
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
1767
3000
11.5
3.5
3.3
1000
44.9 29 14.2x x
1140 737 361x x
88.3
40
0.612
450
4
57
-
2013-2014 Series: Air Curtains / Air Doors
Electric Heated | Water Heated | Ambient (Unheated)
208V/240V/1/60HZ, 208V/240V/3/60HZ, 480V/3/60HZ, 600V/3/60HZ
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
OVERVIEW
Electric Heated Ambient (Unheated)
Water Heated
31
Air Flow
Air Flow
AC1001
Series 1001- a popular model for installation where a decorative, but very functional application is required. These units are floor mounted and stand 79` high and have a maximum rated effective range of 11` (3.5 m). Suitable for installing as a stand alone unit or as a pair can protect across several doors simultaneously. Available also in polished or brushed stainless steel finishes and are ideal in any style of public accessed building.
79E11, 79E16, 79E21 | 79W24 | 79A
AC1001
GENERAL CHARACTERISTICS
79E11 79E16 79E21
208/3/60
36.5
10.7
54.9
16.1
73.4
21.5
2000
3400
2000
3400
2000
3400
7.0
2.1
16,2
9
25,2
14
34,2
19
11.5
3500
11.5
3500
11.5
3500
( ) 18.11, (H) 79.21w
( ) 460, (H) 2012w
161.2
73
161.2
73
170
77
0.272
340
0.272
340
0.272
340
31.5 45.6 62
54 54
MODEL
Voltage V/PH/Hz
Heat Output kBTU/hkW
Air Volume cfmm /h³
Max. Door Height ftm
Тemperature rise °F°C
Max Opening Width. ftmm
Dimensions inmm
Weight lbkghpW
Max. Current A
Sound Level at 5 m (distance) dB(A)
Motor Input
* Based on inlet and outlet water temperatures of 203°F/158°F (95°C/70°C)
THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)
MODEL 79W24
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
97.9
28.7
92.2
27.0
85.0
24.9
81.9
24.0
66.2
19.4
37.5
11.0
Air Тemperature rise °F
°C
64.8
36
61.2
34
55.8
31
54
30
43.2
24
25.2
14
Water Flow USGPHl/s
90.36
0.095
114.13
0.12
180.71
0.19
237.78
0.25
247.29
0.26
133.16
0.14
GENERAL CHARACTERISTICS
79W24
208/1/60
82.0
24.0
1770
3000
7.0
2.1
54
30
11.5
35 00
( )18.11, (H) 79.21w
( ) 460, (H) 2012w
143.5
65
0.272
340
2
54
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Мах. Door Height ft
m
Тemperature rise∗ °F°C
Max Opening Width. ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
Control panel included with every air curtain.Complete with - 3 speed control, Thermostat and 2 heat settings. Can be operated through door switches and sensors. Each control panel can control: 2 – 79E, 79W.
GENERAL CHARACTERISTICS
79A
208/1/60
2000
3400
7.0
2.1
11.5
3.5
( ) 18.11, (H) 79.21w
( ) 460, (H) 2012w
143.5
65
0.272
340
2
54
MODEL
Voltage V/PH/Hz
Air Volume cfm
m /h³
Мах. Door Height ft
m
Max Opening Width. ft
m
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
-
2013-2014 Series: Air Curtains / Air Doors
Electric Heated | Water Heated | Ambient (Unheated)
208V/240V/1/60HZ, 208V/240V/3/60HZ, 480V/3/60HZ, 600V/3/60HZ
SERIES
AVAILABLE OPTIONS
MODELS
AVAILABLE VOLTAGES
OVERVIEW
Electric Heated
Water Heated
33
Air Flow
Air Flow
AC1002
Ambient (Unheated)
Series 1002 - a decorative multipurpose air curtain. Designed to be flush mounted or suspended, for installation up to 11` (3.5 m). This model is designed to be flush mounted or suspended for installation up to 11’ (3.5m). It will give your space elegance with enough air output around your entrance doors to maintain ambient temperatures for the comfort of both clients and employees. Available with halogen lighting, and brushed or polished stainless finish.
79E21, 79E32, 79E43 | 79W50 | 79A
AC1002
Control panel included with every air curtain.Complete with - 3 speed control, Thermostat and 2 heat settings. Can be operated through door switches and sensors. Each control panel can control:1 – 79W, 79A
1
3
2
6,3
4,5
3,7
1
3
2
6,3
4,5
3,7
THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)
MODEL 79W50
Water Temperature at Inlet/Outlet °F
°C
302/158
150/70
266/158
130/70
221/158
105/70
203/158
95/70
176/140
80/60
140/104
60/40
Heat Output kBTU/h
kW
206.1
60.4
193.2
56.6
178.2
52.2
172.0
50.4
138.6
40.6
76.5
22.4
Air Тemperature rise °F
°C
66.6
37
63
35
57.6
32
55.8
31
45
25
25.2
14
Water Flow USGPHl/s
190.22
0.20
237.78
0.25
370.94
0.39
504.10
0.53
513.61
0.54
285.34
0.30
* Based on inlet and outlet water temperatures of 203°F/158°F (95°C/70°C)
GENERAL CHARACTERISTICS
79W50
208/1/60
172
50.4
3240
5500
11.5
3.5
55.8
31
6.6
2000
80. х 36. x 1 .9 4 3 4
2055 925 4х x 3 0
256
116
1.224
900
2.57
57
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Мах. Door Height ft
m
Тemperature rise ∗ °F°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
GENERAL CHARACTERISTICS
79E21 79E32 79E43
208/3/60
73.4
21.5
109.9
32.2
146.8
43.0
3356
5700
3356
5700
3356
5700
11.5
3.5
19.8
11
29.7
16.5
39.6
22
6.6
2000
6.6
2000
6.6
2000
80.9 4 13.4х 36. x
205 х 92 x 3 05 5 4
256
116
256
116
256
116
1.224
900
1.224
900
1.224
900
65 95 125
57 57
MODEL
Voltage V/PH/Hz
Heat Output kBTU/h
kW
Air Volume cfm
m /h³
Max. Door Height ft
m
Тemperature rise °F
°C
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
GENERAL CHARACTERISTICS
79A
208/1/60
3415
5800
11.5
3.5
6.6
2000
80.9 x 36.4 x 13.4
2055 x 925 x 340
242
110
1.224
900
2
54
MODEL
Voltage V/PH/Hz
Air Volume cfm
m /h³
Мах. Door Height ft
m
Length ft
mm
Dimensions in
mm
Weight lb
kg
Motor Input hp
W
Max. Current A
Sound Level at 5 m (distance) dB(A)
-
Canada5000 Dufferin St. Unit 219Toronto, Ontario, M3H 5T5
+1 (888) 894-5717 (Toll Free)[email protected]
www.heatsavingsystems.com
Europe90, Revolutsii hwy, Saint-Peterburg,
Russian Federation , 195279+7(812) 301-99-40+7(812) 380-13-24+7 (812) 327-63-81
+7(812) 327-63-82 (Fax)[email protected]
www.teplomash.ru
2013.09