R E S I D E N T I A L
I N D E X
R E S I D E N T I A L
Air cooling and water heating
Cooling with heat recovery .......................................................................................158
Water cooling
Homes and offices ..........................................................................................................159
Dehumidifiers
Laundry dryers ..................................................................................................................160
Wall mounted ....................................................................................................................161
Wall mounted/floor standing ..................................................................................165
Residential ventilation
Selection guide .................................................................................................................166
Ceiling mounted with heat recovery ..................................................................167
HCC2 accessories .............................................................................................................168
Cupboard and wall mounted with heat recovery ......................................171
Attic mounted with heat recovery .......................................................................176
HCV/HCH accessories ...................................................................................................178
Residential ventilation controllers
Controllers ............................................................................................................................185
TO DRY
TO COOL
TO VENTILATE
157
TO CONTROL
PolyAir Engineering Sàrl Champ Cheval 2CH - 1530 Payerne
+41 26 520 75 [email protected] www.polyair.ch
158
A I R CO O L I N G A N D WAT E R H E AT I N G
CO O L I N G W I T H H E AT R E CO V E R Y
Features
�Cooling down to 7°C (-5°C with hot gas defrost option)
�Rugged PVC coated galvanised steel case
�Wall mounted
�Easy to install and connect
�AW 450SC produces up to 3300 litres of hot water per day at 50°C – enough for 660 typical covers per day
�AW 250SC produces up to 2400 litres of hot water per day at 50°C – enough for 430 typical covers per day
Applications
�Home hot water heating
�Beer and wine cellars
�Waste heat recovery from boiler rooms with water pre-heat capacity
�Launderettes
�Spas and clubs
�Campsites and caravan parks
AW 450 S C
Options
�Hot gas defrost
�Stainless steel case
�High temperature version for heating water to 65°C
�Heat reject unit (required when air cooling has priority over water heating)
�Air filter
Specifications Units AW 250SC AW 450SC
Air temperature rangeWater temperature rangeMax. water flowMin. water flowMax. water resistanceMin. water resistanceWater connections
°C°C
l/minl/minmhdmhd
7*-3610-50
14123.52.8
22mm pipe stub
7*-3610-50
22184.83.5
22mm pipe stubAir flowExternal resistanceFan driveSound level @ 3m
m3/hmmWG
dB(A)
10190
Direct57
16980
Direct59
Power supplySupplyLRAFLAPower consumedProduct size (h x w x d)Weight
V/HzAAA
kWmmkg
220-240/1ph/5013135.50.9
665 x 780 x 34060
220-240/1ph/502020111.8
665 x 1245 x 34095
* -5 with hot gas defrost
159
TO
CO
OL
WAT E R CO O L I N G
H O M E S A N D O F F I C E S
Features
�Domestic sizes giving up to 900 litres per hour of cold water production
�Fully packaged, robust and weatherproof construction
�Quiet operation
�Purpose-built for operation in the Gulf region
�Certified cupronickel WRAS* approved heat exchanger to withstand pool chemicals and allow the unit to be used in a direct system
�Non ozone depleting refrigerant (R134A)
* WRAS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges.
WA 1234 B C
Applications
�Homes and villas
�Plunge pools
Options
�Available in 60Hz
Specifications Units WA 634ACL WA 634ACH WA 1234BC
Air temperature rangeWater temperature range
Output @ 32°C waterInput @ 32°C water
Output @ 10°C waterInput @ 10°C water
°C°C
kWkW
kWkW
0-5510-40
5.51.9
2.81.4
10-5510-40
5.51.9
2.81.4
10-5510-40
9.83.2
5.92.5
Nominal cold water productionMin./max. tank size
l/hl
50060/500
50060/500
900110/1000
Electrical inputPower supplyMax. supply fuseStarting current
kWV/Hz
AA
1.9220-240/1ph/50
1332
1.9220-240/1ph/50
1332
3.2400/3ph/50
1648
Water flowFlow resistanceConnections
l/min ±10%mhdinch
332.1
¾ BSPM
332.1
¾ BSPM
332.1
¾ BSPMNominal air flowFan external resistance (standard)
m³/hPa
150050
150050
300050
Fan typeSound pressure level @ 3mProduct size (w x d x h)Weight
dB(A)mmkg
1 x Centrifugal63
820 x 702 x 762111
1 x Centrifugal63
820 x 702 x 762111
1 x Centrifugal65
1060 x 705 x 807157
* Cooling output and input calculated at +45°C/50% RH ambient air
160
D E H U M I D I F I E R S
L AU N D RY D RY E R S
Features
�Case made of galvanized steel, hood made of easy to clean plastic, service-friendly housing construction
�Space-saving wall mounting
�Blue-Dry®-Technology for particularly energy-saving operation – even at low humidities and temperatures
�Fully hermetic rotary compressor
�Energy-efficient EC-radial fan
�Maintenance-friendly refrigerant circuit with service connector
�Condenser and evaporator made of copper tubes with aluminium fins
�On-demand hot gas defrost system for optimum operation in a cool places
W T 230W T 240W T 250W T 280
Applications
� Laundry drying
� Basements and cellars
� Living rooms
� Warehouses
� Preservation
� Sewage treatment, waterworks
Specifications Units WT 230 WT 240 WT 250 WT 280
Capacity (30°C/80% RH) l/24h 35.5 36.5 57.1 79.2Air flow m3/h 750 830 870 920Energy consumption per kg laundry kWh/kg 0.25 0.25 0.27 0.30Drying time h/min 4/55 5/35 5/23 5/13Operating temperature range °C 3-32 3-32 3-32 3-32Operating humidity range % 35-95 35-95 35-95 35-95Power supply V/Hz 230/1ph/50 230/1ph/50 230/1ph/50 230/1ph/50Sound level dB(A) 61 61 60 60Condensate drain mm 15 x 2 15 x 2 15 x 2 15 x 2Product size (h x w x d) mm 809 x 640 x 345 809 x 640 x 345 809 x 640 x 345 809 x 640 x 345Weight kg 40 40 42 43
Easy to use electronic eDRY®
(Languages: DE/IT/FR/E)
�Operation mode (space drying/laundry drying)
�Display actual humidity
�Setting target humidity
�Program selection (Timer, Turbo-drying)
�Drying Automatic
161
TO
DR
Y
D E H U M I D I F I E R S
WA L L M O U N T E D
C D F 10Features
�Built into a strong and robust powder coated hot galvanized sheet metal cabinet
�Evaporator and condenser coils are epoxy-coated for high corrosion resistance
�The condensate outlet is located at the bottom of the CDF dehumidifier. The outlet stub can be connected to a water hose.
�Easy accessible washable air filters from front cover
�Reciprocating compressor
�Axial fan
�Electronic control and user-friendly display panel
�Active, demand-controlled defrosting
�Available in white and grey
Applications
� Basements and cellars
� Garages and car storage
� Archives and museums
� Churches
� Changing rooms
Optional accessories
�Room hygrostat
�Water tank, grey or white
C D F 10 with water tank
Specifications Units CDF 10
Operating temperature rangeOperating humidity rangeDehumidification @ 30°C/60% RHAir flowPower supplyMax. power consumptionSound pressure level @ 1mRefrigerantWater container capacityProduct size (h x w x d)Weight
°C% RHl/24hm3/hV/HzkW
dB(A)
lmmkg
3-3040-100
7.5220
230/1ph/500.346
R134a5.5
600 x 535 x 24028
162
D E H U M I D I F I E R S
WA L L M O U N T E D
D H 15Features
�Compact design for installation in small areas
�Self contained with fully automatic operation
�Integral humidistat
�Tamper proof controls
�Epoxy polyester painted zintec steel cabinet
�Hot gas defrost for low temperature operation
�Air filter
Applications
� Basements and cellars
� Stairwells
� Garages and car storage
� Libraries
� Drying rooms
� Store rooms
� Unheated premises
Options
�Through the wall version
Specifications Units DH 15AX
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)Product size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/24hkW
m3/hPa
dB(A)
V/HzkWAAA
mmkg
mm ID
0-35150.9225
053
R407c230/1ph/50
0.433.81018
825 x 363 x 3203310
163
TO
DR
Y
D E H U M I D I F I E R S
WA L L M O U N T E D
D H 30
Specifications Units DH 30AX DH 30AXP
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyDehumidifier power inputFLAMaximum supply fuseLRA (compressor start)Heater typeHeat outputFlow rateProduct size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/24hkW
m3/hPa
dB(A)
V/HzkWAAA
kWl/minmmkg
mm ID
0-35301.9700
052
R407c230/1ph/50
0.754.410
15.8Optional LPHW
3.05.0
782 x 270 x 6484016
0-35301.9700
052
R407c230/1ph/50
0.7512.720
15.8Standard Electric
2.0-
782 x 270 x 6484016
Features
�Self contained with fully automatic operation
�Integral humidistat
�Polyester coated evaporator and condenser
�Plastisol coated galvanised steel cabinet
�Hot gas defrost for low temperature operation
�Quiet centrifugal fans
�Remote humidistat and on/off function
Applications
� Drying rooms
� Modular buildings
� Electrical sub-stations
� Sports clubs and changing rooms
� Warehousing and storage
� Museums, libraries and galleries
� Garages
Options
�Through the wall version
�Electric air heater
�LPHW air heater
�Floor stand kit
164
D E H U M I D I F I E R S
WA L L M O U N T E D
D H 60
Specifications Units DH 60AX DH 60AXP
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyDehumidifier power inputFLAMaximum supply fuseLRA (compressor start)Heater typeHeat outputFlow rateProduct size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/24hkW
m3/hPa
dB(A)
V/HzkWAAA
kWl/minmmkg
mm ID
0-35603.5
12800
54R407c
230/1ph/501.27.51330
Optional LPHW5.05.0
1247 x 270 x 6486016
0-35603.5
12800
54R407c
230/1ph/501.2
24.23230
Standard Electric4.0-
1247 x 270 x 6486016
Features
�Self contained with fully automatic operation
�Integral humidistat
�Polyester coated evaporator and condenser
�Plastisol coated galvanised steel cabinet
�Hot gas defrost for low temperature operation
�Quiet centrifugal fans
�Remote humidistat and on/off function
Options
�Through the wall version
�Electric air heater
�LPHW air heater
�Floor stand kit
Applications
� Archives and museums
� Churches
� Changing rooms
� Waterworks
� Garages and car storage
165
TO
DR
Y
C D F 50
D E H U M I D I F I E R S
WA L L M O U N T E D / F LO O R S TA N D I N G
Features
�Built into a strong and robust powder coated hot galvanized sheet metal cabinet
�Evaporator and condenser coils are epoxy-coated for high corrosion resistance
�Fixed to the wall by means of a wall mounting strip supplied with the unit
�Condensate outlet located at the bottom. Outlet stub can be connected to a ¾" hose
�Outside connection to mains
Controls
�Built in electronic hygrostat and thermostat
�Integrated ON/OFF control of humidity and temperature (electric or water heating coils as accessories)
�0-VOLT connection for alarm
�230 V for control valve, exhaust fan and pump/boiler
�RS 485 gate for BMS (Modbus)
Applications
� Archives and museums
� Churches
� Changing rooms
� Waterworks
� Garages and car storage
Optional accessories
�Wireless remote control DRC1
�Floor mounting kit
�Water heating coils
�Control valve for water heating coils
�Electric heating coils
�Exhaust fans
Diodes
BLUE: Power connected, standby mode GREEN: Compressor ON, deicing YELLOW: Remote pairing mode RED: Errors
Defrosting
Active, demand-controlled defrosting is incorporated in the electronic control.
Service
For easy service the refrigerant circuit is supplied with a service valve. The PCB has a USB gate for history data logging for easy fault finding.
Specifications Units CDF 40 CDF 50 CDF 70
Operating temperature rangeOperating humidity rangeDehumidification @ 30°C/60% RHAir flowPower supplyMax. power consumptionSound pressure level @ 1mRefrigerantFilterProduct size (w x d x h)WeightCondensate drain size (stub)
°C% RHl/24hm3/hV/HzkW
dB(A)
mmkg
inch
3-3240-100
30400
230/1ph/500.7846
R407cG3 PPI 15
1010 x 327.8 x 699.956.5
¾
3-3240-100
53680
230/1ph/501.3747
R407cG3 PPI 15
1060 x 327.8 x 699.965¾
3-3240-100
55900
230/1ph/501.550
R407cG3 PPI 15
1495 x 327.8 x 699.975.5
¾
166
R E S I D E N T I A L V E N T I L AT I O N
S E L E C T I O N G U I D E
Model HCC 2 PLA HCV 300 HCV 500 HCV 700 HCV 4/HCV 5 HCH 5 HCH 8
Installation Wall/ceiling void Wall Wall Wall Cupboard/wall Attic Attic
Energy class A (A+ can be obtained with optional accessory kit)
Max air flow (m3/h) 260 280/400/550 280/400/550 280/400/550 275/375 375 530
Max. floor area (m2) 110 150 260 450 200/260 280 350
WxHxD (mm) 600 x 279 x 1122 600 x 1000 x 430 700 x 1050 x 603 700 x 1050 x 750530x1005x434/ 590x1055x584
580x600x1180 780x600x1180
Weight (kg) 34 36.5 49.5 64 32/45 52 70
Duct connection (mm) ø125 ø125 ø160 ø200 ø125/ ø160 ø160 ø250
Heat exchanger Plastic Alu Alu Alu Alu Alu Alu
G4 filter F7 pollen filter + + + + + + +PHI certificate ÷ ÷ ÷ ÷/ SAP Appendix Q listed ÷ ÷ ÷ ÷ ÷/ Demand control + Automatic bypass cooling Manual/
Integrated software bypass ÷ ÷ ÷Frost protection of heat exchanger
Week programs + + +Night mode + + + + + + +Holiday mode + + + + + + +Fireplace mode + + + + Filter alarm Connection of fire/smoke alarm system + + +Connection to geothermal collector + + + + + + +BMS connection KNX connection ÷ ÷ ÷Right/left hand switching ÷ ÷ ÷Wireless remote control + + + + + + +Wired control panel + + + + ÷ Heating coils + + + + + + +PC tool + + + + ÷ ÷ ÷RH sensor + VOC sensor + + + + ÷ ÷ ÷CO2 sensor + + + + + + +
included + optional ÷ not available
Performance Functionalities Accessories
*Depending on local legislation
167
TO
VE
NT
ILA
TE
H CC 2 P L A
R E S I D E N T I A L V E N T I L AT I O N
C E I L I N G M O U N T E D W I T H H E AT R E CO V E RY
Features
� High efficiency heat recovery – up to 94%
� EC fan motors with low energy consumption (low SPI)
� Only 300mm installation headroom height is required
� Time controlled ventilation level, based on 11 different built in pre-programmed week programs. This reduces power consumption in periods with low ventilation demands.
� Summer cooling mode
� Fireplace mode, creating a momentary inside overpressure, to enhance chimney functionality
� Easy-to-install and commissioning solution with built in air measure ports, for easy balancing with PC-Tool
� Electronically left/right fan direction switching, allowing same unit type to adapt any physical installation requirements, regardless of ceiling and wall selection.
� TCP/IP ModBus connection, for inter-operation with Building Management System
Applications
� Private houses
� Villas
� Apartments
Specifications Units HCC 2
Max. air flow (max. @ 100 Pa) m3/h 260Bypass Yes, automaticPerformanceEnergy consumption class (SEC-class), average climate AEnergy consumption class (SEC-class), average climate A+1
Operating range DIBt m3/h 70 to 140Operating range Passivhaus m3/h 70 to 140Efficiency DIBt % 93.8Efficiency Passivhaus % 93Installation surrounding temperature °C +12 - +40Maximum humidity in extract air @ 25°C RH% 65Outdoor temperature (without preheating installed) °C -12 2 - +50Outdoor temperature (with preheating installed) °C -25 - +50CabinetProduct size (w x h x d without bracket) mm 600 x 279 x 1122Duct connections ø mm 125 - femaleWeight kg 34Fire classification of the unit EN 13501 class EDrainage hose included ø/length 1/2" – 2mElectricalPower supply V/Hz 230/1ph/50Max. power consumption (without heater options fitted) W 127
1 Requires an optional Energy Efficiency Class A+ kit (including VOC sensor and RH% sensor). Described under 'Accessories'.2 Preheating is recommended when outside temperatures are below -5°C to ensure balanced operation of the home ventilation unit.
168
R E S I D E N T I A L V E N T I L AT I O N
H CC 2 ACC E S S O R I E S
Wireless remote control
Wired control
Wired control (HCP 10)
Dantherm offers a pre-wired control unit, which is connected to the ventilation unit with a 6m cable. The wired control comes with a white plastic frame and a metal frame for fastening into a standard junction box. Alternatively Dantherm can supply a box to fix to the wall in an appropriate place.
The HCP 10 wired control gives the user the following options:
� Manual control of air change (step 0-4)
� Control of air change with week program
� Demand controlled air change (if RH and VOC sensors are connected)
� Enable summer mode (only extract air)
� Enable manual bypass (requires an optional mechanical bypass to be mounted)
� Enable fireplace mode
� Reading and resetting of alarms, including filter alarm
The wired HCP 10 control offers the installer the possibility of adjusting the air volumes during commissioning without using Dantherm’s PC Tool.
Wireless remote control (HRC 3)
Dantherm offers a wireless remote control, which can be mounted on the wall or placed on a shelf. The remote control is designed for the user, but also includes a special installer menu, allowing the installer to do extensive settings, without the use of the PC Tool.
The remote control has an acoustic alarm that will sound when the filters need to be inspected or replaced. This insures correct maintenance even when the HCC 2 unit is set to demand mode, and regular attention is not towards the remote control.
The user features are:
� Fan speed in manual mode.
� Select demand mode (requires RH and/or VOC sensors to be mounted).
� Select week mode and week program 1-11.
� Manually activated bypass. It closes again automatically.
� Enable fireplace boost mode. Seven minutes with overpressure inside the house for easy ignition of a fireplace.
� Enable away mode in which the unit decreases permanently to speed 1.
� Enable night mode in which the unit decreases to speed 1. The time night mode can be adjusted.
� Remaining filter period + adjustment of same.
� Temperature readings in all four duct connections, including the remote control’s embedded temperature sensor, as well as relative humidity and quality of the extract air (accessory).
� Setting time and date.
169
TO
VE
NT
ILA
TE
R E S I D E N T I A L V E N T I L AT I O N
H CC 2 ACC E S S O R I E S
External electrical preheating coil, 900 WThe electrical heating coil prevents ice building up in the heat exchanger at low temperatures. The heating coil is mounted in the outdoor air duct. The heating coil is connected to and controlled by the HCC 2 controller, which adjusts the heat output so as to ensure an ice-free heat exchanger with the lowest possible energy consumption.
Pre-heat insulation kit for HCC 2This insulation kit is designed for fixing to the HCC 2 preheater. This customized insulation kit protects against thermal bridges, condensation and excessive energy consumption.
Mechanic bypass moduleThe HCC 2 home ventilation unit can be fitted with an automatically controlled bypass damper module, that exploits the colder outdoor air to cool down the home, e.g. after a hot summer’s day, when the outdoor night time temperature falls below the temperature of the house. The bypass module leads all the hot exhaust air past the heat exchanger in order to achieve the best possible cooling effect.
RH% demand sensor (also included in the Energy Efficiency Class A+ kit)The HCC 2 home ventilation unit can be fitted with a humidity sensor (RH%). This sensor will continuously monitor the humidity of the extract air and adjust the air flow level accordingly. This operation is named demand mode. If a wireless remote control is connected, the level will be shown in the display using a 3 level icon.
Using demand mode will result in the correct level of ventilation with lowest possible electrical power consumption. If both VOC and RH% sensors are fitted, the ventilation level is set by the highest demand from just any one of the sensors.
VOC air quality demand sensor (also included in the Energy Efficiency Class A+ kit)The HCC 2 unit can be fitted with a VOC air quality sensor. This sensor will continuously monitor the level of artificial as well as natural organic fumes in the air. Examples of included fumes:
� Natural fumes, e.g. formaldehyde from building materials
� Chemical fumes from sprays, e.g. hair spray or perfumes
� Indoor pollution e.g. from smoking and printing with laser printer
� Fumes from fire retardant substances in carpets, paint and furniture
Using the VOC sensor in demand mode will result in the correct level of ventilation with lowest possible electrical power consumption. If a wireless remote control is connected, the actual VOC level will be shown in the display using a 3 level icon.
Digital plug (bag with 25 pcs.)
This digital plug is connected to the control of the HCC 2 unit. This allows to override the following:
� Fan speed 0, 1, 2, 3, 4
� Fire/smoke/negative pressure /stop + alarm
� High water level stop + alarm
RH% demand sensor
Mechanic bypass module
Pre-heat insulation kit
VOC air quality demand sensor
Digital plug
External electrical preheating coil
170
R E S I D E N T I A L V E N T I L AT I O N
H CC 2 ACC E S S O R I E S
Condensate pump kit
This condensate pump kit is designed for mounting on HCC 2 units where there is no safe drain with fall to a drainage or on units where the drain is too far away (more than 5m horizontal way). The kit is furnished with a bracket for fixing it to the HCC 2 unit, a power supply cable for connection to the HCC 2 unit, pressure equalization hose and drain hose.
Hygrostat, Sauter HSC 120 F001
The hygrostat is connected to the accessory control in case that a higher air change rate is required in rooms with high humidity.
Accessory control HAC 2
One or more of the following functions can be connected to the accessory control:
� After heating coils for water or electricity
� Geothermal preheating/precooling coils
� 24 VDC duct damper outlet
� Stop function inlet
� Fire/smoke detector inlet
� External CO2 sensor for demand control
� External hygrostat
� Filter alarm outlet
� General alarm
HAC 2 comes with 3m cable
Power supply 230VAC – 24VDC, for duct control
Power supply to be mounted in the accessory control if the ventilation unit controls a duct damper.
CO2 sensor
The CO2 sensor is connected to the accessory control if the air change has to be controlled in accordance with the CO2 level in a given room.
USB cable, 3m
USB cable to be used in connection with software update of HCC 2 and Dantherm PC Tool (HPT 1).
Calibration set (bag with 10 sets)
This calibration kit contains 10 sets with each 3m hose, two suction cups with hook and two nipples. The kit is used during commissioning for adjusting the HCC 2 air flows.
Dantherm PC Tool Kit (HPT 1)
The PC Tool Kit contains a USB plug with program and quick guide + USB cable. The Dantherm PC Tool has an installer menu, where the installer can adjust the HCC 2 unit, connect extra accessories, adjust various user settings, read and reset alarms, if any. It also has a user menu, where the user can read and adjust various settings, such as week programs, set points, alarms and historical data about temperatures and air quality (accessory).
Accessory control HAC 2
Power supply 230VAC - 24VDC
Co2 sensor
PC Tool Kit
USB cable, 3m
Condensate pump kit
Hygrostat, Sauter HSC 120 F001
Calibration set
171
TO
VE
NT
ILA
TE
R E S I D E N T I A L V E N T I L AT I O N
C U P B O A R D A N D WA L L M O U N T E D W I T H H E AT R E CO V E RY
Features
� Demand-controlled ventilation with integrated humidity sensor� This reduces power consumption at times with low ventilation
demands� Summer mode, in which supply fan is stopped, and any open
window will supply cooler outside air, lowering the room temperature
� Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality
� High efficiency heat recovery� EC fan motors with extremely low energy consumption (low SPI)� Easy-to-install and commission solution with built -in air pressure
spigots for easy calibration� Highly customizable units, by adding a high variety of internal
as well as external accessories. See more in the 'Accessories' section.
� HCV 300 models takes up only as little space as a 60x60cm cupboard
Applications
� Private houses
� Villas
� Apartments
H C V 300
Specifications Units HCV 300
Max. air flow (max. @ 100 Pa) m3/h 275
Bypass Yes, automatic
PerformanceEnergy consumption class (SEC-class), average climate A
Energy consumption class (SEC-class), average climate A+1
Efficiency EN13141-7 dry (hSUP) % 86
Installation surrounding temperature °C 12 - 50
Outdoor temperature without preheater installed (tODA) °C -12 - +50
Outdoor temperature with preheater installed °C -25 - +50
CabinetProduct size (w x h x d without bracket) mm 600 x 1000 x 430
Ducts Ø mm 125 - female
Weight kg 36.5
Fire classification of the unit EN 13501 class E
Drainage hose included (Ø/length) "/m ¾" - 1m
ElectricalPower supply V/Hz 230/1ph/50
Max. power consumption (without heater options fitted) W 170
172
R E S I D E N T I A L V E N T I L AT I O N
C U P B O A R D A N D WA L L M O U N T E D W I T H H E AT R E CO V E RY
Features
� Demand-controlled ventilation with integrated humidity sensor
� This reduces power consumption at times with low ventilation demands
� Summer mode, in which supply fan is stopped, and any open window will supply cooler outside air, lowering the room temperature
� Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality
� High efficiency heat recovery
� EC fan motors with extremely low energy consumption (low SPI)
� Easy-to-install and commission solution with built -in air pressure spigots for easy calibration
� Highly customizable units, by adding a high variety of internal as well as external accessories. See more in the 'Accessories' section.
Applications
� Private houses
� Villas
� Apartments
H C V 500
Specifications Units HCV 500
Max. air flow (max. @ 100 Pa) m3/h 375
Bypass Yes, automatic
PerformanceEnergy consumption class (SEC-class), average climate A
Energy consumption class (SEC-class), average climate A+1
Efficiency EN13141-7 dry (hSUP) % 86
Installation surrounding temperature °C 12 - 50
Outdoor temperature without preheater installed (tODA) °C -12 - +50
Outdoor temperature with preheater installed °C -25 - +50
CabinetProduct size (w x h x d without bracket) mm 700 x 1050 x 603
Ducts Ø mm 160 - female
Weight kg 49.5
Fire classification of the unit EN 13501 class E
Drainage hose included (Ø/length) "/m ¾" - 1m
ElectricalPower supply V/Hz 230/1ph/50
Max. power consumption (without heater options fitted) W 170
173
TO
VE
NT
ILA
TE
R E S I D E N T I A L V E N T I L AT I O N
C U P B O A R D A N D WA L L M O U N T E D W I T H H E AT R E CO V E RY
Features
� Demand-controlled ventilation with integrated humidity sensor
� This reduces power consumption at times with low ventilation demands
� Summer mode, in which supply fan is stopped, and any open window will supply cooler outside air, lowering the room temperature
� Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality
� High efficiency heat recovery
� EC fan motors with extremely low energy consumption (low SPI)
� Easy-to-install and commission solution with built -in air pressure spigots for easy calibration
� Highly customizable units, by adding a high variety of internal as well as external accessories. See more in the 'Accessories' section.
Applications
� Private houses
� Villas
H C V 700
Specifications Units HCV 700
Max. air flow (max. @ 100 Pa) m3/h 550
Bypass Yes, automatic
PerformanceEnergy consumption class (SEC-class), average climate A
Energy consumption class (SEC-class), average climate A+1
Efficiency EN13141-7 dry (hSUP) % 85
Installation surrounding temperature °C 12 - 50
Outdoor temperature without preheater installed (tODA) °C -12 - +50
Outdoor temperature with preheater installed °C -25 - +50
CabinetProduct size (w x h x d without bracket) mm 700 x 1050 x 750
Ducts Ø mm 200 - female
Weight kg 70
Fire classification of the unit EN 13501 class E
Drainage hose included (Ø/length) "/m ¾" - 1m
ElectricalPower supply V/Hz 230/1ph/50
Max. power consumption (without heater options fitted) W 234
174
R E S I D E N T I A L V E N T I L AT I O N
C U P B O A R D A N D WA L L M O U N T E D W I T H H E AT R E CO V E RY
H C V 4
Features
� Demand-controlled ventilation with integrated humidity sensor
� High efficiency heat recovery
� EC motors with extremely low energy consumption (low SPI)
� Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit
� HCV models are suitable for installation in 60 x 60cm cupboards
� Integrated control panel HCP 4 in front
Applications
� Private houses
� Villas
� Apartments
Specifications Units HCV 4
Max. air flow (max. @ 100 Pa) m3/h 275Bypass Yes, manualPerformanceEnergy consumption class (SEC-class), average climate AEnergy consumption class (SEC-class), average climate A1
Efficiency EN13141-7 dry (hSUP) % 89.5Surrounding temperature where the unit is installed °C 10-50Operational temperature range without pre-heating °C -132 - +50Operational temperature range with pre-heating °C -30 - +50CabinetProduct size (h x w x d standard mounting rail/rail for plan mounting) mm 1005 x 530 x 434/419Duct connection mm 125Weight kg 32Fire classification of the unit EN 13501 class EDrainage hose included (Ø/length) ¾" - 1mElectricalPower supply V/Hz 230/1ph/50Max. power consumption (without heater options fitted) W 88
1 Requires an Energy Efficiency Class A+ kit (including CO2 sensor and HAC 1 accessory control). Described under Accessories. 2 We recommend preheating at temperatures under -6°C to ensure a balanced operation.
175
TO
VE
NT
ILA
TE
R E S I D E N T I A L V E N T I L AT I O N
C U P B O A R D A N D WA L L M O U N T E D W I T H H E AT R E CO V E RY
H C V 5
Features
� Demand-controlled ventilation with integrated humidity sensor
� High efficiency heat recovery
� EC motors with extremely low energy consumption (low SFP)
� Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit
� HCV models are suitable for installation in 60 x 60cm cupboards
� Integrated control panel HCP 4 in front
Applications
� Private houses
� Villas
� Apartments
Specifications Units HCV 5
Max. air flow (max. @ 100 Pa) m3/h 375Bypass Yes, automaticPerformanceEnergy consumption class (SEC-class), average climate AEnergy consumption class (SEC-class), average climate A1
Efficiency EN13141-7 dry (hSUP) % 88Efficiency Passivhaus % 80Surrounding temperature where the unit is installed °C 10-50Operational temperature range without pre-heating °C -132 - +50Operational temperature range with pre-heating °C -30 - +50CabinetProduct size (h x w x d(standard mounting rail/rail for plan mounting) mm 1055 x 590 x 584/569Duct connection mm 160Weight kg 32Fire classification of the unit EN 13501 class EDrainage hose included (Ø/length) ¾" - 1mElectricalPower supply V/Hz 230/1ph/50Max. power consumption (without heater options fitted) W 154
1 Requires an Energy Efficiency Class A+ kit (including CO2 sensor and HAC 1 accessory control). Described under Accessories. 2 We recommend preheating at temperatures under -6°C to ensure a balanced operation.
176
H C H 5
R E S I D E N T I A L V E N T I L AT I O N
AT T I C M O U N T E D W I T H H E AT R E CO V E R Y
Features
� Demand-controlled ventilation with integrated humidity sensor
� High efficiency heat recovery
� EC motors with extremely low energy consumption (low SPI)
� Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit
� HCH models are suitable for installation on uninsulated attics
� Separate HCP 4 control panel included + 2m cable
Applications
� Private houses
� Villas
� Apartments
Specifications Units HCH 5
Max. air flow (max. @ 100 Pa) m3/h 375Bypass Yes, automaticPerformanceEnergy consumption class (SEC-class), average climate AEnergy consumption class (SEC-class), average climate A1
Efficiency EN13141-7 dry (hSUP) % 88Efficiency Passivhaus % 81Surrounding temperature where the unit is installed °C -20 - +50Operational temperature range without pre-heating °C -132 - +50Operational temperature range with pre-heating °C -30 - +50CabinetProduct size (h x w x d(standard mounting rail/rail for plan mounting) mm 600 x 1180 x 580Duct connection mm 160Weight kg 52Fire classification of the unit EN 13501 class EElectricalPower supply V/Hz 230/1ph/50Max. power consumption (without heater options fitted) W 154
1 Requires an Energy Efficiency Class A+ kit (including CO2 sensor and HAC 1 accessory control). Described under Accessories. 2 We recommend preheating at temperatures under -6°C to ensure a balanced operation.
177
TO
VE
NT
ILA
TE
H C H 8
R E S I D E N T I A L V E N T I L AT I O N
AT T I C M O U N T E D W I T H H E AT R E CO V E R Y
� Demand-controlled ventilation with integrated humidity sensor
� High efficiency heat recovery
� EC motors with extremely low energy consumption (low SPI)
� Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit
� HCH models are suitable for installation on uninsulated attics
� Separate HCP 4 control panel included + 2m cable
Applications
� Private houses
� Villas
� Apartments
Specifications Units HCH 8
Max. air flow (max. @ 100 Pa) m3/h 530Bypass Yes, automaticPerformanceEnergy consumption class (SEC-class), average climate AEnergy consumption class (SEC-class), average climate A1
Efficiency EN13141-7 dry (hSUP) % 86Efficiency Passivhaus % 83Surrounding temperature where the unit is installed °C -20 - +50Operational temperature range without pre-heating °C -132 - +50Operational temperature range with pre-heating °C -30 - +50CabinetProduct size (h x w x d(standard mounting rail/rail for plan mounting) mm 600 x 1180 780Duct connection mm 250Weight kg 70Fire classification of the unit EN 13501 class EElectricalPower supply V/Hz 230/1ph/50Max. power consumption (without heater options fitted) W 246
1 Requires an Energy Efficiency Class A+ kit (including CO2 sensor and HAC 1 accessory control). Described under Accessories. 2 We recommend preheating at temperatures under -6°C to ensure a balanced operation.
178
R E S I D E N T I A L V E N T I L AT I O N
H C V / H C H ACC E S S O R I E S
Wireless remote control
Dantherm offers an LCD based wireless remote control, designed either to be mounted on the wall, or to be placed standing on a table or cabinet. This remote control is designed for the user, but also includes a special installer menu, where it is possible for the installer to do extensive settings, without the use of the PC-tool.
The user features are:
� Fan speed in manual mode.
� Select demand mode.
� Select week mode and week program 1-11.
� Manually open bypass for 6 hours. Will close automatically.
� Enable fireplace boost mode. Four minutes with overpressure inside the house, for easy ignition of a fireplace.
� Enable/disable away mode, in which the unit decreases permanently to speed 1. Auto off after four weeks.
� Enable/disable night mode, in which the unit increases to fan speed 1. The hour for enable/disable can be adjusted with appropriate control accessory.
� Filter timer reset
� Temperature readings in all four duct connections, including the remote control’s embedded temperature sensor, as well as relative humidity and quality of the extract air (accessory).
� Setting time and date.
The remote control has an acoustic alarm, that will sound when filter needs to be inspected or replaced. This insures correct maintenance even when the HCC 2 is set to demand mode, and regular attention is not towards the remote control. The wireless remote control uses two AAA alkaline batteries. Battery lifetime up to two years is possible, as the display and remote goes into hibernation mode after two minutes without user interaction.
Wireless remote control
Display with iconsRead actual temperatures, relative humidity,
CO2 level, operation and filter status and alarms, if any
Acoustic alarm
2 menu levelsUser menu
Installer menu
5-way navigation buttonSelection of operation and
control.Adjustment of setpoints
179
TO
VE
NT
ILA
TE
R E S I D E N T I A L V E N T I L AT I O N
H C V / H C H ACC E S S O R I E S
Wired control
Wired control (HCP 10)
Dantherm offers a pre-wired control unit, which is connected to the ventilation unit with a 6m cable. The wired control comes with a white plastic frame and a metal frame for fastening into a standard junction box. Alternatively Dantherm can supply a box to fix to the wall in an appropriate place.
The HCP 10 wired control gives the user the following options:
� Manual control of air change (step 0-4)
� Control of air change with week program
� Demand controlled air change (if RH and VOC sensors are connected)
� Enable summer mode (only extract air)
� Enable manual bypass (requires an optional mechanical bypass to be mounted)
� Enable fireplace mode
� Reading and resetting of alarms, including filter alarm
The wired HCP 10 control offers the possibility of adjusting the air volumes without using Dantherm’s PC Tool.
Hygrostat, Sauter HSC 120 F001
The hygrostat is connected to the accessory control in case that a higher air change rate is required in rooms with high humidity.
Power supply 230VAC – 24VDC, for duct control
Power supply to be mounted in the accessory control if the ventilation unit controls a duct damper.
CO2 sensor
The CO2 sensor is connected to the accessory control if the air change has to be controlled in accordance with the CO2 level in a given room.
USB cable, 3m
USB cable to be used in connection with software update of HCC 2 and Dantherm PC Tool (HPT 1).
Dantherm PC Tool Kit (HPT 1)
The PC Tool Kit contains a USB plug with program and quick guide + USB cable. The Dantherm PC Tool has an installer menu, where the installer can adjust the HCC 2 unit, connect extra accessories, adjust various user settings, read and reset alarms, if any. It also has a user menu, where the user can read and adjust various settings, such as week programs, set points, alarms and historical data about temperatures and air quality (accessory).
Power supply 230VAC - 24VDC
CO2 sensor
Hygrostat, Sauter HSC 120 F001
PC Tool Kit
USB cable, 3m
180
R E S I D E N T I A L V E N T I L AT I O N
H C V / H C H ACC E S S O R I E S
RH% demand sensor (also included in the Energy Efficiency Class A+ kit)
The HCC 2 home ventilation unit can be fitted with a humidity sensor (RH%). This sensor will continuously monitor the humidity of the extract air and adjust the air flow level accordingly. This operation is named demand mode. If a wireless remote control is connected, the level will be shown in the display using a 3 level icon.
Using demand mode will result in the correct level of ventilation with lowest possible electrical power consumption. If both VOC and RH% sensors are fitted, the ventilation level is set by the highest demand from just any one of the sensors.
VOC air quality demand sensor (also included in the Energy Efficiency Class A+ kit)
The HCC 2 unit can be fitted with a VOC air quality sensor. This sensor will continuously monitor the level of artificial as well as natural organic fumes in the air. Examples of included fumes:
� Natural fumes, e.g. formaldehyde from building materials
� Chemical fumes from sprays, e.g. hair spray or perfumes
� Indoor pollution e.g. from smoking and printing with laser printer
� Fumes from fire retardant substances in carpets, paint and furniture
Using the VOC sensor in demand mode will result in the correct level of ventilation with lowest possible electrical power consumption. If a wireless remote control is connected, the actual VOC level will be shown in the display using a 3 level icon.
Accessory control HAC 2
One or more of the following functions can be connected to the accessory control:
� After heating coils for water or electricity
� Geothermal preheating/precooling coils
� 24 VDC duct damper outlet
� Stop function inlet
� Fire/smoke detector inlet
� External CO2 sensor for demand control
� External hygrostat
� Filter alarm outlet
� General alarm
� HAC 2 comes with 3m cable
RH% demand sensor
VOC air quality demand sensor
Accessory control HAC 2
181
TO
VE
NT
ILA
TE
R E S I D E N T I A L V E N T I L AT I O N
H C V / H C H ACC E S S O R I E S
Electric duct heaters
The electric heating coils are designed for installation in the supply or extract air duct. The heating coil is provided with duct connections with a rubber sealing gasket. The heating coil is not suitable for outdoor installation. The control current is connected to the accessory control HAC 1. Connection to supply voltage 230V is made separately.
Electric pre-/after heating coil, 0-10V controlled by the accessory control
The heating coil is controlled by a stepless regulation via the accessory control HAC 1.
Electric pre-/after heating coil, direct control by the built-in thermostat
The heating coil is controlled by the built-in thermostat. Both heating coils are
supplied with a duct sensor. Both heating coils are supplied with a duct sensor.
Capacity, dimensions and weight
The electric heating elements inside a coil are un-finned and therefore the resulting air pressure loss is negligible.
Specifications Units HCV 4 HCV 5 HCH 5 HCH 8
Air volume m3/h 220 300 300 450Heat output kW 0.9 1.2 1.2 1.8Temperature rise °C 13.7 14.2 14.2 13.4Power consumption 1x230V A 4.1 5.5 5.5 8.2Duct connection Ø mm 125 160 160 250Weight kg 3.0 3.5 3.5 5.0
375
AIR
278
42 42 82Ø
Ø+17
Electric pre-/afterheating coil 0-10V
Electric pre-/afterheating coil,direct control
182
R E S I D E N T I A L V E N T I L AT I O N
H C V / H C H ACC E S S O R I E S
Water heating coils
The water heating coil kit includes 2RR, 2-way water valve, 0-10V servo motor, 230/24VAC trafo, duct sensor and tube sensor for frost protection. It is controlled by the accessory control HAC 1.
Water heating coil
Servo motor
2-way water valve
230/24 V AC trafo
*Air in 15°C
HCV 4(CWW 125-2-2.5)
UnitsMax. capacity Supply air temp. 21°C
80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C
Air volume m3/h 85 150 215 85 150 215 85 150 215 85 150 215
Air temp. out* °C 40 36 34 28 25 23 21 21 21 21 21 21Pressure loss Pa 11 28 51 11 28 51 11 28 51 11 28 51Capacity kW 0.7 1.1 1.4 0.4 0.5 0.6 0.2 0.3 0.5 0.2 0.3 0.5Water flow l/h 36 36 72 36 36 36 9 10 23 17 22 28Pressure loss, max. KPa 0.5 0.5 1 0.5 0.5 0.5 0.2 0.2 0.4 0.3 0.4 0.5
HCV 5/HCH 5(CWW 160-2-2.5)
UnitsMax. capacity Supply air temp. 21°C
80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C
Air volume m3/h 145 250 355 145 250 355 145 250 355 145 250 355
Air temp. out* °C 47 43 40 33 31 29 21 21 21 21 21 21Pressure loss Pa 6 15 27 6 15 27 6 15 27 6 15 27Capacity kW 1.6 2.4 3.0 0.9 1.3 1.7 0.3 0.5 0.7 0.3 0.5 0.7Water flow l/h 72 108 144 36 72 72 14 24 35 12 28 30Pressure loss, max. KPa 1.0 3.0 4.0 0.5 1.0 2.0 0.2 0.4 0.5 0.1 0.4 0.5
HCH 8(CWW 250-2-2.5)
UnitsMax. capacity Supply air temp. 21°C
80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C
Air volume m3/h 360 630 360 630 360 630 360 630
Air temp. out* °C 44 40 31 29 21 21 21 21Pressure loss Pa 10 25 10 25 10 25 10 25Capacity kW 3.6 5.3 2.0 3.0 0.74 1.29 0.74 1.28Water flow l/h 144 252 108 144 30 61 40 61Pressure loss, max. KPa 1.0 3.0 1.0 2.0 0.5 1.0 0.7 1.0
HCV 300(CWW 125-2-2.5)
UnitsMax. capacity Supply air temp. 21°C
80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C
Air volume m3/h 85 150 215 85 150 215 85 150 215 85 150 215
Air temp. out* °C 40 36 34 28 25 23 21 21 21 21 21 21Pressure loss Pa 11 28 51 11 28 51 11 28 51 11 28 51Capacity kW 0.7 1.1 1.4 0.4 0.5 0.6 0.2 0.3 0.5 0.2 0.3 0.5Water flow l/h 36 36 72 36 36 36 9 10 23 17 22 28Pressure loss, max. KPa 0.5 0.5 1.0 0.5 0.5 0.5 0.2 0.2 0.4 0.3 0.4 0.5
183
TO
VE
NT
ILA
TE
R E S I D E N T I A L V E N T I L AT I O N
H C V / H C H ACC E S S O R I E S
Water heating coils
The water heating coil kit includes 2RR, 2-way water valve, 0-10V servo motor, 230/24VAC trafo, duct sensor and tube sensor for frost protection. It is controlled by the accessory control HAC 2.
HCV 300(CWW 125-2-2.5)
UnitsMax. capacity Supply air temp. 21°C
80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C
Air volume m3/h 85 150 215 85 150 215 85 150 215 85 150 215
Air temp. out* °C 40 36 34 28 25 23 21 21 21 21 21 21Pressure loss Pa 11 28 51 11 28 51 11 28 51 11 28 51Capacity kW 0.7 1.1 1.4 0.4 0.5 0.6 0.2 0.3 0.5 0.2 0.3 0.5Water flow l/h 36 36 72 36 36 36 9 10 23 17 22 28Pressure loss, max. KPa 0.5 0.5 1 0.5 0.5 0.5 0.2 0.2 0.4 0.3 0.4 0.5
HCV 500/HCV 700** (CWW 160-2-2.5)
UnitsMax. capacity Supply air temp. 21°C
80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C
Air volume m3/h 145 250 355 145 250 355 145 250 355 145 250 355
Air temp. out* °C 47 43 40 33 31 29 21 21 21 21 21 21Pressure loss Pa 6 15 27 6 15 27 6 15 27 6 15 27Capacity kW 1.6 2.4 3.0 0.9 1.3 1.7 0.3 0.5 0.7 0.3 0.5 0.7Water flow l/h 72 108 144 36 72 72 14 24 35 12 28 30Pressure loss, max. KPa 1.0 3.0 4.0 0.5 1.0 2.0 0.2 0.4 0.5 0.1 0.4 0.5
HCV 700**(CWW 250-2-2.5)
UnitsMax. capacity Supply air temp. 21°C
80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C
Air volume m3/h 360 630 360 630 360 630 360 630
Air temp. out* °C 44 40 31 29 21 21 21 21Pressure loss Pa 10 25 10 25 10 25 10 25Capacity kW 3.6 5.3 2.0 3.0 0.74 1.29 0.74 1.28Water flow l/h 144 252 108 144 30 61 40 61Pressure loss, max. KPa 1.0 3.0 1.0 2.0 0.5 1.0 0.7 1.0
*Air in 15°C
** Please be aware that this heater coil has 250mm duct connections, so 2 pcs of Ø200/250mm duct reduction parts are needed for installation with a HCV 700 (Ø200)
184
R E S I D E N T I A L V E N T I L AT I O N
H C V / H C H ACC E S S O R I E S
Water heating coils
Dimensions and weight
Ød B H Ødy F G K L Weightmm kg
HCV 4 (CWW 125-2-2.5) 125 238 180 10 137 40 276 356 3.5HCV 5/HCH 5 (CWW 160-2-2.5) 160 313 255 10 212 40 276 356 5.4
HCH 8 (CWW 250-2-2.5) 250 398 330 10 250 40 276 356 7.7
Panel filters
Panel filters are supplied as a set with either two G4 filters or one G4 filter and one F7 filter. G4 is standard. F7 filters can be used on the supply air as a pollen filter.
Filters
Ødy
H
F B+8
B
L
KG G
Ød B H Ødy F G K L Weightmm kg
HCV 300 (CWW 125-2-2.5) 125 238 180 10 137 40 276 356 3.5HCV 500/HCV 700 (CWW 160-2-2.5)
160 313 255 10 212 40 276 356 5.4
HCV 700 (CWW 250-2-2.5) 250 398 330 10 250 40 276 356 7.7
185
TO
CO
NT
RO
L
R E S I D E N T I A L V E N T I L AT I O N CO N T R O L L E R S
CO N T R O L L E R S
Wireless remote control
Wired control
Wired control (HCP 10)
Dantherm offers a pre-wired control unit, which is connected to the ventilation unit with a 6m cable. The wired control comes with a white plastic frame and a metal frame for fastening into a standard junction box. Alternatively Dantherm can supply a box to fix to the wall in an appropriate place.
The HCP 10 wired control gives the user the following options:
� Manual control of air change (step 0-4)
� Control of air change with week program
� Demand controlled air change (if RH and VOC sensors are connected)
� Enable summer mode (only extract air)
� Enable manual bypass (requires an optional mechanical bypass to be mounted)
� Enable fireplace mode
� Reading and resetting of alarms, including filter alarm
The wired HCP 10 control offers the possibility of adjusting the air volumes without using Dantherm’s PC Tool.
Wireless remote control (HRC 3)
Dantherm offers a wireless remote control, which can be mounted on the wall or placed on a shelf. The remote control is designed for the user, but also includes a special installer menu, allowing the installer to do extensive settings, without the use of the PC Tool.
The remote control has an acoustic alarm that will sound when the filters need to be inspected or replaced. This insures correct maintenance even when the HCC 2 unit is set to demand mode, and regular attention is not towards the remote control.
The user features are:
� Fan speed in manual mode.
� Select demand mode (requires RH and/or VOC sensors to be mounted).
� Select week mode and week program 1-11.
� Manually open bypass. It closes again automatically.
� Enable fireplace boost mode. Seven minutes with overpressure inside the house for easy ignition of a fireplace.
� Enable away mode in which the unit decreases permanently to speed 1.
� Enable night mode in which the unit decreases to speed 1. The time night mode can be adjusted.
� Remaining filter period + adjustment of same.
� Temperature readings in all four duct connections, including the remote control’s embedded temperature sensor, as well as relative humidity and quality of the extract air (accessory).
� Setting time and date.
186
R E S I D E N T I A L V E N T I L AT I O N CO N T R O L L E R S
CO N T R O L L E R S
Control panel
The drawing below shows the buttons, LEDs and sound outlets on the control panel which is included with the unit and the remote control which is an optional accessory.
Status LED:Green = OKYellow = change filterRed = system fault
Manual control of fan speedFan speed 01234Fire place function
Acoustic alarm
Manual bypassSummer mode
Nominal air volumeFan step 3 adjusted using potentiometers on rear of the control panel
Automatic demand controlFan speed (0)123
Current fan speedShown for 2 mins. after actuation
Control panel
The HCV units, has an built-in foil based control panel, with four buttons for controls, and nine LED feedback signals.
*Accessory
Auto fanShort press -Week programLong press - Demand*
Warning / AlarmRed LED - AlarmOrange LED - Filter warningLong press - Filter reset
Fan speed LED indication
Manual fanShort press - Fan speed
Long press - fireplace mode
BypassShort press - 6 hours bypass*Long press - Summer mode
PC Tool Kit
Dantherm PC Tool Kit (HPT 1)
The PC Tool Kit contains a USB plug with program and quick guide + USB cable. The Dantherm PC Tool has an installer menu, where the installer can adjust the HCC 2 unit, connect extra accessories, adjust various user settings, read and reset alarms, if any. It also has a user menu, where the user can read and adjust various settings, such as week programs, set points, alarms and historical data about temperatures and air quality (accessory).