© Copyright 2013 IMS Company. All rights reserved. An ISO 9001:2008 Registered Quality Company HYDRA AIR COOLED MOLD CIRCULATOR Model MC90AC #163525 INSTRUCTION MANUAL Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: [email protected] Website: www.imscompany.com February 2013 IMS Company 10373 Stafford Road Chagrin Falls, OH 44023-5296

Upload: others

Post on 19-Mar-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

© Copyright 2013 IMS Company. All rights reserved. An ISO 9001:2008 Registered Quality Company1

HYDRA AIR COOLED MOLD CIRCULATOR

Model MC90AC

#163525

INSTRUCTION MANUAL

Telephone: (440) 543-1615Fax: (440) 543-1069

Email: [email protected]: www.imscompany.com

February 2013IMS Company10373 Stafford RoadChagrin Falls, OH 44023-5296

TABLE OF CONTENTS

Specifications ............................................................................................ 1 Safety Summary ............................................................................................ 2 Description ............................................................................................ 3 Installation ............................................................................................ 3 Initial Start-Up ............................................................................................ 6 Normal Operation ............................................................................................ 7 Maintenance ............................................................................................ 8 Troubleshooting ............................................................................................ 9 Parts Identification Photos Figure 1, Front and Right Side .................................................................. 11 Figure 2, Rear and Right Side View ........................................................ 12 Figure 3, Control Panel ............................................................................. 13 Figure 4, Controller ................................................................................... 14 Electrical Schematic ..........................................................................................15 Replacement Parts .......................................................................................... 16 Maintenance Records & Notes ............................................................................ 17

INSERTS Warranty Information ..................................................................................... Insert

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

1

SPECIFICATIONS

Temperature Range ............................................... 250F maximum; minimum can be as low

as 15F above the ambient air temperature, but also depends on how much heat energy the mold is putting into the circulating water

Voltage .................................................................. 230/60/1, 230/60/3 or 460/60/3; see serial # tag on machine

Amps ...................................................................... 50 @ 230/60/1; 30 @ 230/60/3; 15 @ 460VControls:

Type .................................................. Self-tuning PID-Type MicroProcessor Voltage .............................................. 120 VAC

Accuracy ........................................... Within 1% of setpoint Pump/Motor ........................................................... 1-hp, 2850-rpm centrifugal pump rated at

30 gpm @ 38 psi; coupled to AC motor; air-cooled.

Heater (230-460/60/3) ........................................... 9kwHeater (230/60/1) ................................................. 6kw Fan Motor ............................................................... 1/4 hp, 1750 amp, 3-phase Tank ....................................................................... 12-gallon Mold Connections .................................................. 1” NPT Mold Supply Outlet ................................................. 1” NPT Overall Size ............................................................ 35.38" L x 23.38" W x 34" H Shipping Size (crated) ............................................ 35" L x 35" W x 58" H Shipping Weight ..................................................... 320 lbs. (crated)

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

2

SAFETY SUMMARY

This manual uses the following words to show different levels of danger:

DANGER indicates that you are very likely to be killed or injured if you don't take the needed steps to avoid the hazard. This is the highest level of warning.

WARNING indicates that you could be killed or injured if you don't avoid the hazard.

CAUTION indicates you could receive moderate or minor injuries, or equipment could be damaged if you don't avoid the hazard.

DANGER LIVE ELECTRIC PARTS could cause DEATH or SHOCK. Lock out and tag out power before doing wiring. Only qualified electricians are to do electrical work.

WARNING

OIL in this machine could cause FIRE. Do not use any oil in this machine.

CAUTION

FITTINGS that are too tight could DAMAGE PUMP. WEIGHT OF PIPES could DAMAGE PUMP. Do not overtighten fitting on pump discharge.

WARNING Fan turns on suddenly . Could cause serious injury. Keep covers closed.

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

3

DESCRIPTION

The Model MC90AC water circulator controls mold temperature by circulating a mixture of water and glycol through channels in the mold. It can maintain temperatures as low as 15 F above the ambient air temperature or as high as 250 F.

The Model MC90AC consists of a stainless steel tank, air-cooled pump and motor, an electric heater, a water-to-air heat exchanger with electric fan for cooling, and electrical controls, all mounted on a welded steel, powder coated finished frame with casters for portability.

INSTALLATION

Installation must be done only by qualified plumbers and electricians.

1. Inspect Shipment Inspect carton containing unit. Remove machine from carton. Inspect machine for damage. Report any damage to carrier.

2. Move Circulator into Position Position the circulator as close to mold as possible; shorter hoses lose less heat. Make sure heat from this unit will not damage any other machine or material.

3. Connect Discharge Line Run a hose to mold from 1" NPT pump discharge. (See photo on page 12 to identify parts.)

Hose must be rated for 250°F and 100 psi with hot water and ethylene glycol. IMS stocks several hoses that work well for this purpose. For additional information concerning a hose that suits your needs, contact an IMS customer service representative at 1-800-537-5375 (U.S.A. & Canada).

If mold has more than one inlet, use a manifold near mold, and a single line to feed manifold. This will help prevent heat-loss. IMS also stocks manifolds for this purpose. For further information, contact an IMS customer service representative.

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

4

INSTALLATION (continued)

4. Connect Return Line Run the same type of hose used on the discharge line between 1" NPT tank inlet and mold outlet or manifold.

5. Fill Tank a. Use only a mixture of water and

inhibited ethylene glycol (or inhibited propylene glycol) in this circulator. If oil were used, the copper sheathing on the heater element would burn the oil and would not last. Also, the fluid flow pattern through the tank is not designed for thick fluids like oil.

Other reasons to use only glycol and water are:

- Straight water is too corrosive for this application.

- Pure ethylene glycol without inhibitors becomes acidic and corrosive in operation and will not transfer heat well.

- Automotive anti-freeze also becomes acidic when used in a relatively open system such as this machine. Its inhibitors break down in a short time, forming a gel that prevents heat transfer. Also, automotive anti-freeze contains abrasives that will destroy the pump seal.

b. Decide on the ratio of ethylene (or propylene) glycol to water.

(1) The higher the glycol concentration the better the corrosion resistance and the higher the temperature at which the circulator can be run.

(2) The lower the glycol concentration the better the heat transfer ability.

(3) Use the lowest glycol concentration that will reach the temperature you need, but use at least 30% for corrosion resistance.

NOTE Tank capacity is 12 gallons of hot water/glycol. Since water/glycol expands 15% when hot, never use more than 10 gallons cold. Always use at least 8 gallons cold so you are sure the heaters are covered even when some of the fluid is in the mold and hoses.

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

5

INSTALLATION (continued)

(4) 80% ethylene glycol will reach about 250°F.

30% ethylene glycol will reach about 219°F, but will have almost twice the heat transfer ability that 80% would have.

6. Optional Make any other connections your application requires. Installing insulating wrap around hoses will help prevent heat loss. For information concerning hose insulation, contact an IMS customer service representative at 1-800-537-5375.

7. Connect to Power a. Connect only to voltage listed on

machine's serial number tag.

b. Install power cord that meets local codes. Heater is 9kW (230/60/1 is 6kW), pump motor is 1 hp. Fan motor is 1/2 hp. See serial tag for full-load amp rating.

b. Connect to a fused disconnect or circuit breaker with a minimum amp capacity of 40 amps for 230 volts and 25 amps for 460 volts.

c. Lock out / tag out power to circuit where you are going to connect circulator. Hard wire to fused disconnect or install plug so machine can be moved easily.

d. Do not turn power on to circuit until doing checks in INITIAL STARTUP, below.

DANGER LIVE ELECTRIC PARTS could cause DEATH or SHOCK. Lock out and tag out power before doing wiring. Only qualified electricians are to do electrical work.

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

6

INITIAL START-UP

1. Power must be locked out and tagged out.

2 Remove front panel (below control panel). See photo on page 11. All other panels must be in place.

3. Check plumbing installation.

4. Check wiring installation.

5. Turn on plant power to circuit. Turn machine’s main disconnect circuit breaker on (P. 11, Figure 1).

6. Check direction of pump rotation. It must be clockwise when viewed from end of motor. Press START button and let pump run for a few seconds; then shut it off and use a flashlight to observe motor rotation. If direction is reversed, have qualified electrician lock out / tag out power and reverse any two power leads.

7. Re-Install front panel.

8. Press START button again and let unit run.

9. Check for plumbing leaks while machine is running. If there are leaks:

a. Stop machine. Lock out and tag out power.

b. Correct leaks before starting up again.

10. Check fluid level. Ensure that fluid level reaches at least “min” on sight glass after mold and lines are filled with fluid.

Do not fill to maximum level – fluid will expand when heated, and could overflow the tank.

DANGER LIVE ELECTRIC PARTS could cause DEATH or SHOCK. Lock out and tag out power before doing wiring. Only qualified electricians are to do electrical work.

WARNING Fan turns on suddenly . Could cause serious injury. Use extreme caution when running this machine with any cover removed while checking motor rotation. . Covers must be in place for proper airflow. Re-install covers before going into operation.

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

7

NORMAL OPERATION

1. Circulator must have been installed according to INSTALLATION and must have gone through checks detailed in INITIAL START-UP.

2. Turn on power to circuit. Turn circuit breaker on.

3. Press PUMP ON button. The PUMP ON light will come on. The pump must remain on at all times. The heater and fan will not work if the pump is turned off.

The RETURN TEMPERATURE DISPLAY will show the temperature of the water returning from the mold.

The controller will show the TANK TEMPERATURE as the top set of numbers on the controller. The output temperature will be a couple degrees higher than the tank temperature, due to friction through the pump.

The SETPOINT will be shown as the bottom set of numbers on the controller.

4. Turn HEATER CIRCUIT switch on. (If you know that you will not be using heat, you can leave this switch off.) The HEATER CIRCUIT ON light will stay on whenever the heating circuit is on. This does not mean that the heater is on; it only means that the heater circuit is available if the controller calls for heat.

5. Set temperature setpoint to needed level.

Keep in mind that the mold temperature does not match the fluid temperature you set. When heating, the mold is usually cooler than the fluid; when cooling, the mold is usually a little hotter. Controller will turn on power to heater or will turn on cooling fan to maintain temperature.

To adjust the setpoint (see figure 3 on page 8), press the UP arrow to increase the setpoint or the DOWN arrow to decrease the setpoint.

6. If the tank temperature falls below the setpoint:

- The OP1 light on the controller will come on, indicating that the control relay is sending power to the heater power relay.

- If the heating circuit is on, the heater will come on.

- You will see the tank temperature rise until it meets the setpoint.

DANGER LIVE ELECTRIC PARTS could cause DEATH or SHOCK. Lock out and tag out power before doing service. Only qualified electricians are to do electrical work.

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

8

NORMAL OPERATION (continued)

7. If the tank temperature rises above the setpoint:

- The OP2 light on the controller will come on, indicating that the control relay is sending power to the cooling fan power relay.

- The cooling fan will come on.

- You will see the tank temperature fall until it meets the setpoint (or reaches the lowest temperature that the ambient temperature allows.)

8. To shut down circulator:

a. Turn down temperature, to allow heaters to cool.

b. After about 5 minutes, push red stop button.

MAINTENANCE

1. Check tank level often; the water should show on the sight glass. Always check when water is cold.

2. See component manuals for repair procedures. All parts are available from IMS.

3. Clean filter often. Use vacuum. If necessary, use detergent and water. Dry thoroughly.

4. Keep heat exchanger coils (radiator) clean. Use soft brush.

WARNING Fan turns on suddenly . Could cause serious injury. Lock out / tag out power before removing cover to clean heat exchanger. Covers must be in place for proper airflow. Re-install covers before going into operation.

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

9

TROUBLESHOOTING

1. Motor and Heater Not Working:

- Check water level. It should be between the red lines on the sight glass. The low-level float switch shuts off power to the machine if the water level drops too low.

- Is main disconnect ON?

- Is machine plugged in?

- Is there power to circuit that machine is plugged into?

- Turn machine circuit breaker OFF then ON.

- Press STOP switch fully. Then press START switch.

- Have qualified electrician check function of float switch.

2. Tank temperature below setpoint and not rising. Pump is on.

- Is HEATER CIRCUIT switch ON?

- Is controller’s OP1 light on?

- Compare tank temperature reading to return temperature reading.

- Have qualified electrician check controller output relay.

- Have qualified electrician check heater power relay.

- Have qualified electrician check heater elements.

DANGER LIVE ELECTRIC PARTS could cause DEATH or SHOCK. Lock out and tag out power before doing service. Only qualified electricians are to do electrical work.

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

10

TROUBLESHOOTING (continued)

3. Tank temperature above setpoint and not falling. Pump is on.

- Is the FAN light on?

- Can you hear feel hot air coming through the vents in the top?

- Is controller’s OP2 light on?

- Are all covers on machine? You will not get good airflow across the heat exchanger (radiator) if any covers are removed.

- Compare tank temperature reading to return temperature reading.

- Have qualified electrician check controller output relay.

- Have qualified electrician check fan contactor and overload.

WARNING Fan turns on suddenly . Could cause serious injury. Use extreme caution when checking fan function. Qualified electrician only. Covers must be in place for proper airflow. Re-install covers before going into operation.

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

11

Figure 1

FRONT AND LEFT SIDE VIEW

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

12

Figure 2

REAR AND RIGHT SIDE VIEW

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

13

Figure 3

CONTROL PANEL

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

14

Figure 4

CONTROLLER

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

16

REPLACEMENT PARTS

Pump/Motor Assembly - 3 Phase ............ 161851

Pump/Motor Assembly - 1 Phase ............... 162977

Air Filter ....................................................... 162609

Heating element, 230 volt ............................ 148639

Heating element, 460 volt ............................ 148812

Mercury Contactor ....................................... 106192

Controller ..................................................... 163528

Return Temperature Display ........................ 161839

Motor Starter Contactor ............................... 160234

Motor Starter Overload, 230V - 3 Phase ..... 158872 (1.6 - 2.5 amp)

Motor Starter Overload, 230V - 1 Phase ..... 162061 (4 - 6 amp)

Motor Starter Overload, 460V - 3 Phase ...... 158978 (1 - 1.6 amp)

Motor Starter Overload, 230V - 1 Phase ...... 163017 (7 - 10 amp)

Pump On/Off Switch .................................... 158874

Breaker, 240/60/3, 40 AMP

Breaker, 460/60/3, 25 AMP

Breaker, 240/60/1, 50 AMP

Indicator Lights (Pump, Heater, Fan) ........... 106263

Thermocouple, Tank/Process (36”) .............. 160317

Thermocouple, Return (54”) ......................... 162072

Water Sight Glass Assembly ....................... 160321

Low Level Switch ......................................... 161770

Fan Motor - 3 Phase .................................... 161984

Fan Motor - 1 Phase .................................... 163024

Fan Blades ................................................... 161823

Heat ON Toggle Switch ............................... 158902

High Temperature Limit Switch .................... 162549

IMS Company Model MC90AC Mold Temperature Controller

February, 2013

17

MAINTENANCE RECORD AND NOTES