Page 1: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

AIR CONDITIONERS

Page 2: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

We’re dedicated to crafting air conditioners that last

For over 60 years, Mitsubishi Electric has been the pioneer in air conditioner technology in Japan. Priced at a premium in the market, our high standards of craftsmanship, pride and passion for quality continues to lead the industry and inspires other manufacturers to raise their own standards. This commitment to manufacturing durable air conditioners has made Mitsubishi Electric a lifetime partner you can trust for consistent and long-lasting cooling and comfort.

MONOZUKURIMonozukuri is a Japanese philosophy meaning ‘obsession with craftsmanship.’ It drives the Japanese to pursue perfection. It can be seen and felt down to a product’s smallest details. It’s in every Mitsubishi Electric Air Conditioner.

02

Page 3: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

TESTING FORHARSH CONDITIONSExtreme tests on our air conditioners confirm that our designs are built to last.

MITSUBISHI ELECTRIC. QUALITY YOU CAN BELIEVE IN.

MEQ is a hallmark of Mitsubishi Electric Quality. Look for this symbol for an assurance that your air conditioner has met stringent quality standards that stand head and shoulders above the competition.

MANUFACTURING OUROWN KEY PARTSOur design and engineering expertise is applied to manufacturing key parts such as the compressor and inverter.

QUALITY CONTROL FORTHE REAL WORLDAll products are inspected to ensure that your air conditioner works just as well at home as it does in our factories.

OVER 60 YEARSOF INNOVATIONOur history as a pioneer in air conditioner technology is proof of the durability of our products.

03

Page 4: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

04

Page 5: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

How do we craft a durable air conditioner?

Testing For Harsh ConditionsExtreme tests on our air conditioners confirm that our designs are built to last.

Our air conditioners are put through the worst, to give you our best. This ensures that there’s less risk of break downs to give you peace of mind and confidence that your air conditioner will pass any test with flying colours.

05

Page 6: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

SEMICONDUCTORAs the brain of your air conditioner,

the semiconductor is able to intelligently control the compressor

to minimise power consumption.

MOTOR/FANA highly e�cient DC fan motor drives the fan of the outdoor unit while the newly designed propeller fan maximises air flow from the lungs of the air conditioner e�ciently.

COMPRESSORThe compressor is the heart of the air conditioner. Employing Mitsubishi Electric’s proprietary technology, we are able to achieve both high e�ciency and high power.

Our design and engineering expertise is applied to manufacturing key parts such as the compressor and inverter.

Manufacturing OurOwn Key Parts

06

Page 7: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

Because our standards are so high, we take full control of manufacturing key parts such as the compressor and inverter to guarantee they work consistently well for many years. All you have to do is sit back and enjoy our quiet cooling and comfort.

07

Page 8: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

All products are inspected to ensure that your air conditioner works just as well at home as it does in our factories.

Quality ControlFor The Real World

08

Page 9: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

As an example of our product inspection, we connect all outdoor units one by one directly to a test indoor unit. We’re proud to take this extra step for you. It’s just one of the ways we minimise repair and replacement costs to give you a trouble-free air conditioner and true value for money.

09

Page 10: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

Our history as a pioneer of air conditioner technology is proof of the durability of our products.

Over 60 YearsOf Innovation

The first Mitsubishi

Electric room air

conditioner

Inverter air conditioner

delivers power and

energy e�ciency

World’s first cross-flow fan

allows for a smaller and lighter air

conditioner

10

Page 11: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

World’s first ‘Personal

Twin Flow’ with di�erent

temperatures in the room

Our history as a pioneer of air conditioner technology assures our customers that Mitsubishi Electric is the best choice for an air conditioner that they will enjoy for a long time.

An air conditioner with a sleek

design

11

Page 12: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

Creating your comfortThe Mitsubishi Electric Brand Story

Every day, we keep millions of people in homes and businesses worldwide comfortable.

As an industry leader, it’s always been our passion to create and perfect technologies that deliver a long-lasting cooling experience. To do this, we design our air conditioners with durability in mind.

Our commitment to quality means you will enjoy the same cooling comfort throughout the years as you feel on day one.

12

Page 13: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

PIONEERS OF A NEW STANDARD OF COMFORTFor over 100 years, Mitsubishi Electric has researched wind technology to bring the most comfortable breeze into your home. We invented the world’s first cross-flow fan air conditioner, which allowed for a smaller and lighter air conditioner. We then pioneered the idea of split air conditioners, which separated the compressor from the indoor unit for the very first time, making a previously noisy experience quiet and peaceful. These technologies have set the benchmark for cooling comfort that others in the industry now follow.

LONG-LASTING COOLING THROUGH DURABILITY IN DESIGNOur air condit ioners are bui lt to last, so your comfort lasts for years to come. Our promise of durabil ity comes from our strength as a general electronics company, which enables us to bring together advanced technologies from our diverse expertise. We apply the highest standards to manufacturing our own key parts such as the compressor, motor and semiconductor. In this way, we’re confident that your air conditioner wil l work consistently well through the years.

CREATING COMFORT ON A GLOBAL SCALECaring for the environment is our way of helping to keep our earth comfortable for future generations. The durability of our products reduces the demand for natural resources, while energy e�cient products reduce carbon dioxide emissions so that you can enjoy coolness, without compromising the health of our planet.

13

Page 14: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

Nano Platinum Filter

Vertical Vane

Air Purifying Filter

Horizontal Vane

Front Panel

E X C E L L E N T F E A T U R E S

EASY TO CLEAN

Our innovative Removable Design allows you to easily dismantle the

indoor unit’s removable components for thorough cleaning even at hard to

clean places! Enjoy cleaner, healthier air free from bacteria and maintain

NANO PLATINUM FILTER

antibacterial and deodorizing effects. The three-dimensional surface size

while raising room comfort to a higher level.

ECONO COOL MODE

In Econo Cool Mode, the swing operation functions vertically in various

effect with reduced power consumption even though set temperature is

automatically adjusted 2°C higher.

THREE MAIN INVERTER COMPONENTS

Mitsubishi Electric’s All DC Inverter Air Conditioner applies All DC Inverter

Technology in its three primary components to outperform conventional

DC inverters.

Outdoor Temperature 35ºC

Cooling Temperature 27ºC

Body Surface Temperature 35ºC

The Cooling Effect of ECONO COOL Mode*

* Provided by the factory of Mitsubishi Electric

Outdoor Unit Fan Motor1 Joint Lap DC

Compressor Motor2

Indoor Unit Fan Motor2

INDOOR UNIT OUTDOOR UNIT

Outdoor Temperature 35ºC

Cooling Temperature 25ºC

Body Surface Temperature 30ºC

The Cooling Effect of Conventional Cool Mode*

Cooling starts immediately with the push of a button

Once activated, this mode continues for 15 minutes

POWERFUL COOLAchieve comfortable temperature in less time!

Just push the powerful Cool button when you need to cool your rooms

quickly - on a warm day or when you have guests coming over.

14

Page 15: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

*PAH Series under heating operation.

NOISE-REDUCING DESIGNWider fan diameter and the use of uneven fan blade pitch in 5 varied

noise level. Other innovative noise reduction technologies like heat

exchanger and metal strip further help reduce noise level to as low

as 21dB* - lower than the standard 25dB noise level

of a recording studio.

E X C E L L E N T F E A T U R E S

BLUE FIN CONDENSER

The heat exchanger of the outdoor unit is specially coated with

anti-corrosion treatment to enhance its durability, and protect it

against corrosion from air, water and other corrosive elements.

conditioner.

SUPER WIDE AND LONG-DISTANCE AIRFLOW

side to another in a long and narrow room, or through an open type

living room, kitchen or workroom.

DURABLE ELECTRONIC METAL HOUSING

This special box metal housing protects electronic circuitry from

dust - ensuring durability, reliability and short circuit

protection.

LCD HANDHELD CONTROLLER

Get complete control of your air conditioner - with our well-designed

LCD Handheld Controller in your hand!

* For R32 model only

15

Page 16: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

COMPRESSOR

The compressor is the heart of the air

achieved by using Mitsubishi Electric’s proprietary technology.

I N V E R T E R S E R I E S

ALL MITSUBISHI ELECTRIC INVERTER TECHNOLOGY

Mitsubishi Electric’s JP Series features advanced inverters that utilize cutting edge technology, developed worldwide through many years of

PROPELLER FAN AND DC FAN MOTOR INVERTER POWER MODULE

The Inverter Power Module is the brain of the air conditioner. It minimizes power consumption by adjusting the frequency.

Propeller Fan

Our newly designed propeller fan maximizes

with reduced noise.

Poki-poki Motor

using original dense winding technology.

Heat Caulking

Original heat caulking method minimizes

DC Fan Motor

Our high efficiency fan motor drives the

an equivalent AC motor.

* Applies to inverter models only.

16

Page 17: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

D U A L B A R R I E R C O A T I N G

Dual and Single Barrier Coating

prevent dust and grime from

getting into the air conditioner.

* Applicable to JP & LN models only

STATE-OF-THE-ART COATING TECHNOLOGYDual Barrier Coating (Fan) Single Coating (Heat exchanger)

Comparison of dirt on fan

hydrophobic dirt penetration (oil mist/cigarette smoke) while “hydrophilic particles” prevent hydrophilic dirt accumulation

Image after 10 years Dual Barrier Coating Used

FAN

What happens if the inside of your air conditioner gets dirty?

Accumulated dirt inside your air conditioner can lead to “loss of energy conservation due to lower operating efficiency”. It can also cause air discharged from the unit to smell bad.

The Dual Barrier Coating applied to the inner surface of our air conditioner prevents dirt from getting in, effectively eliminating such problems.

17

Page 18: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

3D I-See Sensor can oscillate in 150° to proactively detect floor and wall

temperature. It then customizes the airflow, reducing the possibility of

temperature differences, ensuring that room temperature is even. The result is

added comfort and reduced power consumption.

Dual Barrier Coating used• Heat exchanger• Fan• Air duct

R 3 2 I N V E R T E R S U P E R D E L U X E L N S E R I E S

DOUBLE-FLAP

directions to ensure outstanding levels of

comfort.

Viruses

Microparticle(PM2.5)

Allergens

Dust

Bacteria

Molds

DUAL-BARRIER COATING

Mitsubishi Electric’s proprietary coating

prevents dust and grease accumulation.

C lean, f resh a i r i s v i ta l fo r ensur ing

healthy surroundings for us. To achieve

th is , Mi tsub ish i E lec t r i c ’s power fu l

plasma-based filter system effectively

removes air pollutants, allergens, dust,

bacteria and viruses.

• Grease mist• Cigarette smoke

• Dust• Dirt

18

Page 19: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

R32 INVERTER SUPER DELUXE LN SERIES

MSZ/MUZ-LN10/13VF(R UBY R ED )

MSZ/MUZ-LN10/13VF(P EA R L W HITE )

MSZ/MUZ-LN10/13VF(O NYX B LACK )

INVERTER SUPER DELUXE

MODEL INDOOR MSZ-LN10VF MSZ-LN13VF

OUTDOOR MUZ-LN10VF MUZ-LN13VF

Cooling Capacity Range (Btu/hr) 3,412 – 11,942 3,412 – 12,966

Capacity (Rated) Btu/h 8,871 12,966

kW 2.6 (1.00 – 3.50) 3.8 (1.00 – 3.80)

CSPF Star Rating

Power Input (kW) 0.53 1.00

Running Current (A) 2.8 4.8

Power Supply 230V, 50Hz (Single Phase)

INDOOR MSZ-LN10VF MSZ-LN13VF

Air Flow (m3/min) Lo – Hi 4.3 – 11.9 4.3 – 12.8

Air Flow (CFM) 152 – 420 152 – 452

Noise Level [dB(A)] Lo – Hi 19 – 42 19 – 42

Dimension (mm) W x D x H 890 x 233 x 307 890 x 233 x 307

Net Weight (kg) 15.5 15.5

OUTDOOR MUZ-LN10VF MUZ-LN13VF

Noise Level [dB(A)] Lo – Hi 46 46

Dimension (mm) W x D x H 800 x 285 x 550 800 x 285 x 550

Net Weight (kg) 35.5 35.5

Connection Method FLARED

Pipe Size Gas mm 9.52 9.52

Outer Diameter Liquid mm 6.35 6.35

Max. Piping Length (M) 20 20

Max. Height Difference (M) 12 12

• Anti-allergy enzyme• Deodorising• Quattro

19

Page 20: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

[ Nor mal ] [ Fast Cool ing ]

R32 I N V E R T E R D E L U X E G R S E R I E S

Fast CoolingFast Cooling is the most essential desire in air conditioner.

MITSUBISHI ELECTRIC’s Fast Cooling brings

you fast refreshment in your life.

Pressing the Fast Cooling button makesthe compressor reach its maximum frequency remarkably faster than in Normal Operation.

Lowers the air outlet temperature faster than Inverter Normal Operation.

Fast Cooling mode starts immediately with the push of a button. Accoding to preference,air direction can be changed freely.

Quickly cools the room with the highest-volume, and low-temperature airblow at 2min. after operation.

LED Backlight withluminous buttonOnce the luminous backlight button is pressed, the setting can be easily checked in the dark.

Error code displayError codes are displayed on the remote controller for trouble shooting.

Auto Vane ControlUp and Down/Left and Right

Auto vanes can be moved left and right,and up and down using the remote controller.

New Remote ControllerNew stylish and compact remote controller features easy-read big display and simple button positionwith fundamental functions.

01 Compressor Freguency Image 02 Air Outlet Temperature 03 Thermography 04 Fast Cooling Button

Horizontal Airflow/Auto Vane Control

*For the details, please refer to the operating Instructions

20

Page 21: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

R32 I N V E R T E R D E L U X E G R S E R I E S

INVERTER DELUXE

MODEL INDOOR MSY-GR10VF MSY-GR13VF MSY-GR15VF MSY-GR18VF MSY-GR24VF MSY-GR28VF

OUTDOOR MUY-GR10VF MUY-GR13VF MUY-GR15VF MUY-GR18VF MUY-GR24VF MUY-GR28VF

Cooling Capacity Range (Btu/hr) 3,753 – 11,601 4,777 – 13,989 5,459 – 16,378 6,142 – 20,472 6,142 – 26,614 7,165 – 31,390

Capacity (Rated) Btu/h 9,554 12,642 14,672 17,742 24,225 27,978

kW 2.8 (1.1 – 3.4) 3.7 (1.4 – 4.1) 4.3 (1.6 – 4.8) 5.2 (1.8 – 6.0) 7.1 (1.8 – 7.8) 8.2 (2.1 – 9.2)

CSPF Star Rating

Not Applicable

Power Input (kW) 0.77 1.1 1.27 1.4 2.02 2.5

Running Current (A) 3.9 5.3 5.8 6.2 9.1 11.2

Power Supply 230-240V, 50Hz (Single Phase)

INDOOR MSY-GR10VF MSY-GR13VF MSY-GR15VF MSY-GR18VF MSY-GR24VF MSY-GR28VF

Air Flow (m3/min) S.Lo – Lo – Hi – S.Hi 4.0 – 5.3 – 9.5 – 11.4 4.3 – 5.3 – 9.5 – 11.8 5.5 – 6.5 – 10.3 – 13.3 9.0 – 11.2 – 15.7 – 19.5 9.6 – 12.0 – 16.9 – 20.3 9.8 – 12.8 – 17.7 – 21.8

Air Flow (CFM) S.Lo – Lo – Hi – S.Hi 141 – 187 – 336 – 403 152 – 187 – 336 – 417 194 – 230 – 364 – 470 318 – 396 – 554 – 689 339– 424 – 597 – 717 346 – 452 – 625 – 770

Noise Level [dB(A)] S.Lo – Lo – Hi – S.Hi 18 – 24 – 38 – 42 19 – 24 – 38 – 43 25 – 29 – 40 – 46 27 – 33 – 44 – 49 28 – 36 – 45 – 51 30 – 37 – 46 – 53

Dimension (mm) W x D x H 838 x 229 x 280 838 x 229 x 280 838 x 229 x 280 1100 x 257 x 325 1100 x 257 x 325 1100 x 257 x 325

Net Weight (kg) 10.0 10.0 10.0 17.0 17.0 17.0

OUTDOOR MUY-GR10VF MUY-GR13VF MUY-GR15VF MUY-GR18VF MUY-GR24VF MUY-GR28VF

Noise Level [dB(A)] 47 49 50 52 57 56

Dimension (mm) W x D x H 699 x 249 x 538 699 x 249 x 538 800 x 285 x 550 800 x 285 x 550 800 x 285 x 714 840 x 330 x 880

Net Weight (kg) 21.5 25.0 30.0 31.5 38.0 48.0

Connection Method FLARED

Pipe Size Gas mm 9.52 9.52 9.52 12.7 12.7 15.88

Outer Diameter Liquid mm 6.35 6.35 6.35 6.35 6.35 6.35

Max. Piping Length (M) 20 20 20 20 30 30

Max. Height Difference (M) 12 12 12 12 15 15

MSY/MUY-GR

MSY-GR18VFMSY-GR24VFMSY-GR28VF

Optional

21

Page 22: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

NON-INVERTER STANDARD

MODEL INDOOR MS-JR10VF MS-JR13VF MS-JR18VF MS-JR24VF

OUTDOOR MU-JR10VF MU-JR13VF MU-JR18VF MU-JR24VF

Cooling Capacity Range (Btu/hr) 9,212 12,283 17,401 21,837

Capacity (Rated) Btu/h 9,212 12,283 17,401 21,837

kW 2.70 3.60 5.10 6.40

CSPF Star Rating

Power Input (kW) 0.84 1.12 1.66 2.01

Running Current (A) 3.7 5.0 7.5 9.1

Power Supply 230V, 50Hz (Single Phase)

INDOOR MS-JR10VF MS-JR13VF MS-JR18VF MS-JR24VF

Air Flow (m3/min) Lo – Hi – S.Hi 4.4 – 9.2 – 11.8 5.5 – 10 – 12.3 10.9 – 14.9 – 18.8 12.9 – 17.7 – 21.3

Air Flow (CFM) Lo – Hi – S.Hi 155 – 325 – 417 194 – 353 – 434 385 – 526 – 664 456 – 625 – 752

Noise Level [dB(A)] Lo – Hi – S.Hi 25 – 39 – 45 29 – 41 – 47 34 – 44 – 49 37 – 45 – 50

Dimension (mm) W x D x H 799 x 232 x 290 799 x 232 x 290 923 x 250 x 305 1100 x 238 x 325

Net Weight (kg) 9.0 9.0 13.0 16.0

OUTDOOR MU-JR10VF MU-JR13VF MU-JR18VF MU-JR24VF

Noise Level [dB(A)] Lo – Hi 50 50 51 54

Dimension (mm) W x D x H 718 x 255 x 525 718 x 255 x 525 718 x 255 x 525 840 x 330 x 880

Net Weight (kg) 26 29 33.5 52

Connection Method FLARED

Pipe Size Gas mm 9.52 12.7 12.7 15.88

Outer Diameter Liquid mm 6.35 6.35 6.35 6.35

Max. Piping Length (M) 20 20 30 30

Max. Height Difference (M) 10 10 10 10

R32 N O N - I N V E R T E R J R S E R I E S

MS/MU-JR

MS-JR18VFMS-JR24VF

22

Page 23: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

R32 I N V E R T E R J P S E R I E S

MSY/MUY-JP

INVERTER STANDARD

MODEL INDOOR MSY-JP10VF MSY-JP13VF MSY-JP15VF MSY-JP18VF MSY-JP24VF

OUTDOOR MUY-JP10VF MUY-JP13VF MUY-JP15VF MUY-JP18VF MUY-JP24VF

Cooling Capacity Range (Btu/hr) 2,730 – 9,212 3,071 – 12,624 4,094 –14,330 4,436 – 18,084 5,459 – 22,860

Capacity (Rated) Btu/h 8,871 12,283 14,330 17,742 22,519

kW 2.6 (0.80 – 2.70) 3.6 (0.90 – 3.70) 4.2 (1.20 – 4.20) 5.2 (1.30 – 5.30) 6.6 (1.60 – 6.70)

CSPF Star Rating

Power Input (kW) 0.95 1.29 1.44 1.86 2.01

Running Current (A) 5.0 6.0 6.9 8.5 9.2

Power Supply 230V, 50Hz (Single Phase)

INDOOR MSY-JP10VF MSY-JP13VF MSY-JP15VF MSY-JP18VF MSY-JP24VF

Air Flow (m3/min) S.Lo – Lo – Hi – S.Hi 3.95–5.87–9.42–12.82 5.25–6.88–10.83–12.32 6.33–7.72–11.42–12.92 6.33–8.68–15.33–15.33 7.17–9.47–15.17–19.0

Air Flow (CFM) S.Lo – Lo – Hi – S.Hi 139 – 207 – 333 – 453 185 – 243 – 383 – 435 224 – 273 – 403 – 456 224 – 307 – 542 – 542 253 – 334 – 536 – 671

Noise Level [dB(A)] S.Lo – Lo – Hi – S.Hi 21 – 25 – 37 – 43 22 – 28 – 40 – 43 26 – 31 – 42 – 46 28 – 33 – 44 – 49 30 – 37 – 45 – 51

Dimension (mm) W x D x H 838 x 228 x 280 838 x 228 x 280 838 x 228 x 280 838 x 228 x 280 923 x 250 x 305

Net Weight (kg) 8.0 8.5 8.5 9.0 12.5

OUTDOOR MUY-JP10VF MUY-JP13VF MUY-JP15VF MUY-JP18VF MUY-JP24VF

Noise Level [dB(A)] 50 51 51 52 55

Dimension (mm) W x D x H 660 x 235 x 454 699 x 249 x 538 699 x 249 x 538 800 x 285 x 550 800 x 285 x 714

Net Weight (kg) 18 22.5 24.5 31.5 37

Connection Method FLARED

Pipe Size Gas mm 9.52 9.52 9.52 12.7 12.7

Outer Diameter Liquid mm 6.35 6.35 6.35 6.35 6.35

Max. Piping Length (M) 20 20 20 20 30

Max. Height Difference (M) 12 12 12 12 15

Optional

23

Page 24: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

R32 N O N - I N V E R T E R H N S E R I E S

NON-INVERTER STANDARD

MODEL INDOOR MS-HN10VF MS-HN13VF MS-HN18VF MS-HN24VF

OUTDOOR MU-HN10VF MU-HN13VF MU-HN18VF MU-HN24VF

Cooling Capacity Range (Btu/hr) 8,871 12,283 17,401 21,837

Capacity (Rated) Btu/h 8,871 12,283 17,401 21,837

kW 2.6 3.6 5.1 6.4

CSPF Star Rating

Power Input (kW) 0.82 1.14 1.67 2.03

Running Current (A) 3.6 5.1 7.7 9.1

Power Supply 230V, 50Hz (Single Phase)

INDOOR MS-HN10VF MS-HN13VF MS-HN18VF MS-HN24VF

Air Flow (m3/min) Lo – Hi – S.Hi 4.4 – 9.5 – 11.8 5.5 – 10 – 11.6 10.9 – 14.9 – 18.8 12.9 – 17.7 – 21.3

Air Flow (CFM) Lo – Hi – S.Hi 155 – 336 – 417 194 – 353 – 410 385 – 526 – 664 456 – 625 – 752

Noise Level [dB(A)] Lo – Hi – S.Hi 25 – 39 – 45 29 – 41 – 47 34 – 44 – 49 37 – 45 – 50

Dimension (mm) W x D x H 799 x 232 x 290 799 x 232 x 290 923 x 250 x 305 1100 x 238 x 325

Net Weight (kg) 9.0 9.0 13.0 16.0

OUTDOOR MU-HN10VF MU-HN13VF MU-HN18VF MU-HN24VF

Noise Level [dB(A)] 49 50 51 54

Dimension (mm) W x D x H 718 x 255 x 525 718 x 255 x 525 718 x 255 x 525 840 x 330 x 880

Net Weight (kg) 28 32 33.5 50.5

Connection Method FLARED

Pipe Size Gas mm 9.52 12.7 12.7 15.88

Outer Diameter Liquid mm 6.35 6.35 6.35 6.35

Max. Piping Length (M) 20 20 30 30

Max. Height Difference (M) 10 10 10 10

MS/MU-HN

MSY-HN18VFMSY-HN24VF

24

Page 25: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

R 4 1 0 A I N V E R T E R G J / G K S E R I E S

MSY/MUY-GJ / MSY/MUY-GK

INVERTER STANDARD

MODEL INDOOR MSY-GJ10VA MSY-GJ13VA MSY-GK18VA MSY-GK24VA

OUTDOOR MUY-GJ10VA MUY-GJ13VA MUY-GK18VA MUY-GK24VA

Cooling Capacity Range (Btu/hr) 3,753 – 10,236 3,753 – 12,624 5,118 – 20,472 8,189 – 26,614

Capacity (Rated) Btu/h 8,871 10,918 17,401 22,519

kW 2.6 (1.1 – 3.0) 3.2 (1.1 – 3.7) 5.1 (1.5 – 6.0) 6.6 (2.4 – 7.8)

CSPF Star Rating

Power Input (kW) 0.80 1.03 1.45 1.83

Running Current (A) 3.9 5.0 6.5 8.2

Power Supply 230-240V, 50Hz (Single Phase)

INDOOR MSY-GJ10VA MSY-GJ13VA MSY-GK18VA MSY-GK24VA

Air Flow (m3/min) Lo – Hi – S.Hi 4.6 – 7.6 – 9.6 4.1 – 7.7 – 10.5 9.0–11.2–15.6–17.7 9.6–11.9–16.8–19.3

Air Flow (CFM) Lo – Hi – S.Hi 162 – 268 – 339 145 – 272 – 317 318–396–551–625 339–420–593–682

Noise Level [dB(A)] Lo – Hi – S.Hi 21 – 36 – 43 22 – 36 – 43 28 – 33 – 44– 49 30 – 36 – 46 – 51

Dimension (mm) W x D x H 788 x 234 x 295 788 x 234 x 295 1100 x 238 x 325 1100 x 238 x 325

Net Weight (kg) 9.0 9.0 16.0 16.0

OUTDOOR MUY-GJ10VA MUY-GJ13VA MUY-GK18VA MUY-GK24VA

Noise Level [dB(A)] 47 48 52 55

Dimension (mm) W x D x H 684 x 255 x 540 684 x 255 x 540 800 x 285 x 550 840 x 330 x 880

Net Weight (kg) 25 24 35 50

Connection Method FLARED

Pipe Size Gas mm 9.52 9.52 12.7 15.88

Outer Diameter Liquid mm 6.35 6.35 6.35 6.35

Max. Piping Length (M) 20 20 30 30

Max. Height Difference (M) 12 12 12 15

MSY-GK18VAMSY-GK24VA

25

Page 26: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

R 4 1 0 A N O N - I N V E R T E R D E L U X E G K S E R I E S

NON-INVERTER DELUXE

MODEL INDOOR MS-GK10VA MS-GK13VA MS-GK18VA MS-GK24VA

OUTDOOR MU-GK10VA MU-GK13VA MU-GK18VA MU-GK24VA

Cooling Capacity Range (Btu/hr) 9,212 12,283 17,742 22,519

Capacity (Rated) Btu/h 9,212 12,283 17,742 22,519

kW 2.7 3.6 5.2 6.6

CSPF Star Rating

Power Input (kW) 0.75 1.00 1.44 1.83

Running Current (A) 3.4 4.5 6.4 8.4

Power Supply 230V, 50Hz (Single Phase)

INDOOR MS-GK10VA MS-GK13VA MS-GK18VA MS-GK24VA

Air Flow (m3/min) S.Lo – Lo – Hi – S.Hi 5.8–7.7–10.3–12.3 6.6–8.7–11.0–13.8 13.1–15.5–18.5–22.0 13.7–15.9–18.7–22.0

Air Flow (CFM) S.Lo – Lo – Hi – S.Hi 204 – 271 – 363 – 434 233 – 307 – 388 – 487 462 – 527 – 653 – 776 483 – 561 – 660 – 776

Noise Level [dB(A)] S.Lo – Lo – Hi – S.Hi 26 – 32 – 39 – 44 29 – 36 – 42 – 47 35 – 41 – 46 – 53 37 – 42 – 47 – 53

Dimension (mm) W x D x H 799 x 232 x 290 799 x 232 x 290 1100 x 238 x 325 1100 x 238 x 325

Net Weight (kg) 9.0 10.0 16.0 16.0

OUTDOOR MU-GK10VA MU-GK13VA MU-GK18VA MU-GK24VA

Noise Level [dB(A)] 47 50 53 56

Dimension (mm) W x D x H 718 x 255 x 525 718 x 255 x 525 800 x 285 x 550 840 x 330 x 880

Net Weight (kg) 24.5 33.5 40 63

Connection Method FLARED

Pipe Size Gas mm 9.52 12.7 15.88 15.88

Outer Diameter Liquid mm 6.35 6.35 6.35 6.35

Max. Piping Length (M) 20 20 30 30

Max. Height Difference (M) 10 10 10 10

MS-GK18VAMS-GK24VA

MS/MU-GK

26

Page 27: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air

R 4 1 0 A N O N - I N V E R T E R H K S E R I E S

NON-INVERTER STANDARD

MODEL INDOOR MS-HK10VA MS-HK13VA MS-HK17VA MS-HK24VA MS-HK28VA

OUTDOOR MU-HK10VA MU-HK13VA MU-HK17VA MU-HK24VA MU-HK28VA

Cooling Capacity Range (Btu/hr) 8,701 12,283 16,207 21,837 26,614

Capacity (Rated) Btu/h 8,701 12,283 16,207 21,837 26,614

kW 2.55 3.6 4.75 6.4 7.8

CSPF Star Rating

Not Applicable

Power Input (kW) 0.82 1.16 1.69 2.21 2.78

Running Current (A) 3.7 5.2 7.6 9.9 12.5

Power Supply 230V, 50Hz (Single Phase)

INDOOR MS-HK10VA MS-HK13VA MS-HK17VA MS-HK24VA MS-HK28VA

Air Flow (m3/min) Lo – Hi – S.Hi 4.4 – 10 – 12.2 5.8 – 10.2 – 11.8 7.4 – 13.1 – 15.8 12.5 – 17.1 – 20.1 14.7 – 18.1 – 20.1

Air Flow (CFM) Lo – Hi – S.Hi 155 – 353 – 431 205 – 360 – 417 261 – 463 – 558 441 – 604 – 710 519 – 639 – 710

Noise Level [dB(A)] Lo – Hi – S.Hi 26 – 40 – 44 29 – 42 – 48 34 – 46 – 50 37 – 45 – 50 39 – 47 – 50

Dimension (mm) W x D x H 799 x 232 x 290 799 x 232 x 290 799 x 232 x 290 1100 x 238 x 325 1100 x 238 x 325

Net Weight (kg) 9.0 9.0 9.5 16.0 16.0

OUTDOOR MU-HK10VA MU-HK13VA MU-HK17VA MU-HK24VA MU-HK28VA

Noise Level [dB(A)] 47 51 51 54 55

Dimension (mm) W x D x H 718 x 255 x 525 718 x 255 x 525 800 x 285 x 550 840 x 330 x 880 840 x 330 x 880

Net Weight (kg) 24 35 36.5 56.5 72

Connection Method FLARED

Pipe Size Gas mm 9.52 12.7 12.7 15.88 15.88

Outer Diameter Liquid mm 6.35 6.35 6.35 6.35 9.52

Max. Piping Length (M) 20 20 30 30 30

Max. Height Difference (M) 10 10 10 10 15

MS-HK24VAMS-HK28VA

MS/MU-HK

27

Page 28: Air Cond Brochure (28 pp) · Accumulat ed dirt inside your air conditioner can lead to “loss of energy conservat ion due to lower operating efficiency”. It can also cause air