agilent technologies 16700b and 16702b logic analysis …agilent technologies’ 16700 series logic...

16
Agilent Technologies 16700B and 16702B Logic Analysis Systems Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) ® E s t a blishe d 1 9 8 1

Upload: others

Post on 23-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

Agilent Technologies 16700B and 16702B Logic Analysis Systems

Advanced Test Equipment Rentalswww.atecorp.com 800-404-ATEC (2832)

®

Established 1981

Page 2: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

2

Agilent Technologies’ 16700 Series logic analysissystems help design teamsovercome time-to-marketobstacles and meet toughengineering challenges—frombasic circuit board turn-on tovalidating signal integrity.

With their wide variety ofmeasurement capabilities, the16700B and 16702B high-performance modular systemsenable you to rapidlyconsolidate data into meaningfulinsight while giving you the mostcomplete view of your system’sbehavior. And since accurateacquisition starts with probing,we also offer reliable,unobtrusive probes that make iteasy to connect your Agilentlogic analyzer to your systemunder test.

As the innovator of logicanalysis, Agilent (formerlyHewlett-Packard) continuesto provide leading-edgesolutions that evolve withyour changing needs. Themodular form factor ofthe 16700 Series is thekey to their long-termvalue. You purchase onlythe capability you neednow, then expand as yourneeds evolve.

Configuring these modularsystems is as easy as 1, 2, 3.Select your choice of productsthat will (1) Connect, (2) Acquire, and (3) View/Analyzethe data from your system undertest. For example, you canchoose the timing/state logicanalyzer modules, oscilloscopeand pattern generator modulesand data post-processing andprotocol tools that meet yourspecific needs.

From basic board turn-on tosignal integrity validation

Introduction

www.agilent.com/find/la-systems

Figure 1. The 16700B and16702B high-performancemodular systems enable youto rapidly consolidate datainto meaningful insight.

Figure 2. The AgilentTechnologies’ 16700 Series logicanalysis systems help designteams meet tough engineeringchallenges—from basic circuitboard turn-on to validatingsignal integrity.

connect1 2 3acquire view & analyze

Page 3: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

3

connect1 2 3acquire view & analyze

The power and flexibility to provide themost complete view of system behavior

Modular Systems

Agilent Modular 16700 Series Logic Analysis System Mainframes

Agilent Technologies’ modularlogic analysis systems providethe ultimate power and flexibilityto match your digital systemdebug needs. Configure a logicanalysis system that provides acomplete view of your system’s

behavior. Select the measure-ment modules, probing andanalysis options suited for yourspecific application that resultsin efficient debug and validation.

• Configure a basic or multi-framesystem suited to your needs

• Protect your investment with asystem that adapts to multiple,current and future projects

• View cross-domain measurements,correlated in time

• Easily master powerful logic analysis capabilities with the16702B’s touch-screen interface

Model No.

Interface Control

Measurementcapability

Timing and state analysis, pattern generation, oscilloscope

16700B and 16702BOptions

Option 001 – Add 17-inch 1280 x 1024 monitor Option 003 – 256 MB system RAM, 4 MB video RAM Option 008 – 18 GB external data drive Option 009 – external removable hard drive Option 012 – multiframe module

16702B Modular System

Touch screen, knobs, and dedicated hot keys (mouse, keyboard

also provided)

16700B Modular System

Mouse, keyboard

16701B Expansion Frame

N/A

Number of Slots 5 5 5

Display Type(s) andResolution

Internal: 12.1 inch color touchscreen, 800 x 600

External: Supports resolutions up to1600 x 1200 with option 003.

Requires external display.Supports up to 1280 x 1024

standard, 1600 x 1200 requiresoption 003.

N/A

Data Viewing Types

Standard: Waveform, listing, histogram, chart, compare

Module specific: eye diagrams

Optional software tool sets: source code, protocol decode,serial analysis, system performance analysis (SPA)

N/A

Connectivity

Time-correlate logic analyzer trace to external Infiniium 54800 Series oscilloscope.Automated de-skew and tracking of markers.

Offline analysis, e-mail on trigger, individual user logins for network security

Remote programmability via Microsoft ® Active X/COM for PCs and TCP/IPsocket based ASCII commands for UNIX ®.

Remote access of the analyzer from a web browser (web-enabled).

File transfer and storage via mapped shares or mounted drives (Windows® and UNIX)

N/A

Page 4: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

4

www.agilent.com/find/la-systems

Logic Analyzer Probing Solutions

Probing Method(Application)

Signal Type Max. DataRate

Min. SignalAmplitude

Model Number

Channels Logic AnalyzerCompatibility

Equivalent LoadCapacitance

ConnectorlessProbingQuick connectionto many signals ina small footprintwithout requiringa header designedinto the target

Differential or single-endedclock, Single-ended data

Differential or single-ended clock,

Differential or single-ended data

Single-ended clock, Single-ended data

> 2.5 Gb/s

250 mV p-p

Vmax– Vmin200 mV

500 mVp-p

E5390A(Soft touch)

E5387A(Soft touch)

E5394A

(Soft touch)

34

17

34

90-pin cableconnector

40-pin cable

connector

< 0.7 pF

< 0.7 pF

ConnectorProbingQuick connectionto many signalsin a smallfootprint,connector isdesigned intotarget

Differential or single-endedclock, Single-ended data

Differential or single-ended clock,

Differential or single-ended data

Single-ended clock, Single-ended data

1.5 Gb/s

600 Mb/s

[1]

250 mV p-p

Vmax–Vmin200 mV

300 mV p-p

500 mV p-p

500 mV p-p

250 mV p-p

500 mV p-p

E5378A (100-pin Samtec)

E5379A (100-pin Samtec)

E5380A (38-pin Mictor)

E5385A(100-pin Samtec)

E5346A(38-pin Mictor)

E5339A(38-pin Mictor)

E5351A [2]

(38-pin Mictor)

34

17

34

34

34

34

34

90-pin cableconnector

40-pin cableconnector

1.5 pF

3 pF

Flexibility and choice in creating qualityconnections to your target system

Agilent Logic Analyzer Probing Solutions

• Easily connect with reliable,electrically and mechanicallyunobtrusive probing solutions

• Achieve low loading (< 0.7 pF), an easy connection and a smallfootprint with soft touchconnectorless probes

• Gain access to individual, widelydispersed signals with Agilent's

new differential and single-ended general-purpose lead sets.

Accurate measurements startwith reliable probing. AgilentTechnologies offers a widevariety of probing accessoriesthat support general-purposeand application-specificmeasurement needs.

Figure 3. Agilent’s soft touch probescombine high-density, low loadingand differential capability into areliable, space-saving package.

[1] Equivalent to the data rate of the logic analyzer the probe is attached to.[2] Requires isolation networks installed on the target.

connect1

General-Purpose Flying-Lead SetFlexibleconnection toindividual signals

Differential or single-endedclock, Single-ended data

Differential or single-endedclock, Differential data

Single-ended clock,Single-ended data

1.5 Gb/s

[1]

250 mV p-p

Vmax–Vmin200 mV

600 mV p-p

E5382A

E5381A

E5383A

17

17

17

90-pin cableconnector

40-pin cableconnector

1.3 pF

0.9 pF

1.5 pF

1.5 pF

3.0 pF

Page 5: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

5

Model No. 16760A[4] 16753A/54A/55A/56A[4] 16750B/51B/52B 16740A/41A/42A

Channels/Module(Max. Channels onSingle Time Baseand Trigger)

34(170)

68(340)

68(340)

68(340)

Supported SignalTypes

Single-ended,Differential

Single-ended,Differential

Single-ended Single-ended

Setup/HoldWindow(With Eye Finder),AdjustmentResolution

500 ps,10 ps

1 ns (600 ps typical),80 ps typical

1.25 ns,100 ps

1.25 ns,100 ps

Eye Scan Yes Yes N/A N/A

Max. TransitionalTiming Rate

400 MHz 600 MHz 400 MHz 400 MHz

Max. MemoryDepth (Half/FullChannels)[1]

128M/64M[2] 16753A: 2M/1M16754A: 8M/4M

16755A: 32M/16M16756A: 128M/64M

16750B: 8M/4M16751B: 32M/16M16752B: 64M/32M

16740A: 2M/1M16741A: 8M/4M

16742A: 32M/16M

High-SpeedTiming Zoom[3]

N/A 4 GHz (250 ps) with64 K depth

2 GHz (500 ps) with 16 K depth

2 GHz (500 ps)with 16 K depth

Max. TimingSampling Rate(Half/FullChannels)

800 MHz (1.25 ns)

1.2 GHz (833 ps) /600 MHz (1.67 ns)

800 MHz (1.25 ns) /400 MHz (2.5 ns)

800 MHz (1.25 ns) /400 MHz (2.5 ns)

Max. State Clock 1.5 Gb/s 600 MHz 400 MHz 200 MHz

Configure custom measurement solutionsfor demanding applications

Measurement Modules

A wide variety of timing andstate analysis modules providethe speed and memory depth toisolate and analyze your debugproblems. Create a customsolution or expand your existinganalysis system by selecting thetiming/state analyzer, patterngenerator, or oscilloscopemodules that meet your debugand validation needs.

• Choose from a wide variety ofmeasurement modules

• Acquire differential and single-ended signals with state analysisup to 1.5 Gb/s, 4-GHz timingzoom and memory depths up to 128 M samples

• Quickly validate signal integritywith hundreds of simultaneouseye diagrams

Module Ordering Information for Agilent state and timing modules

[1] Increased memory depth in half-channel timing mode only [2] 128 M in half-channel 1.25 Gb/s and .5 Gb/s modes only[3] All channels, all the time, simultaneous state and timing through same probe[4] Probes ordered separately

NOTE: Probes are ordered separately. Please specify probes when ordering to ensure the correct connection betweenyour logic analyzer and the device under test.

2 acquire

Figure 4. Modularity providesconfiguration flexibility tomeet your measurementneeds, now and in the future.

90-pin cable connector 40-pin cable connector

Page 6: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

6

Scopes, Pattern GeneratorAgilent oscilloscopes for 16700 Series

www.agilent.com/find/la-systems

16720A

Maximum clock speed

Memory depth

Channels per module

Maximum number ofchannels per time base

Stimulus commands

Logic levels supported

Ordering information

Half channels

300 MHz

16 M vectors

24

120

Initialize, block, repeat, and break macros

5 V TTL, 3 state TTL, 3 state CMOS, 3 state 3.3V, ECL, 5 V PECL, 3.3 V LVPECL, 3 state 2.5 V,

3 state 1.8 V, LVDS

Order at least one clock pod for eachmodule used as a master and at least

one data pod for every 8 output channels

Pod options for 16720A

Option 011 TTL clock pod & lead setOption 013 3 state TTL/CMOS data pod & lead setOption 014 TTL data pod & lead setOption 015 2.5 V clock pod & lead setOption 016 2.5 V 3 state data pod & lead setOption 017 3.3 V clock pod & lead setOption 018 3.3 V 3 state data pod & lead setOption 021 ECL clock pod & lead setOption 022 ECL (terminated) data pod & lead setOption 023 ECL (unterminated) data pod & lead setOption 031 5 V PECL clock pod & lead setOption 032 5 V PECL data pod & lead setOption 033 3.3 V LVPECL clock pod & lead setOption 034 3.3 V LVPECL data pod & lead setOption 041 1.8 V clock pod & lead setOption 042 1.8 V 3 state data pod & lead setOption 051 LVDS clock pod & lead setOption 052 LVDS data pod & lead set

Full channels

180 MHz

8 M vectors

48

240

Model No. 16534AOscilloscope

Module

Infiniium 54800 Serieswith E5850A TimeCorrelation Fixture

Oscilloscope Type

Maximum Bandwidth

Maximum Sampling Rate

Maximum Memory Depth

Channels PerOscilloscope

Maximum Number ofChannels on a SingleTime Base and Trigger

Internal Module

500 MHz

2 GSa/s

32 K

2

8

External

6 GHz

20 GSa/s

32 M

2 and 4

4

2 acquire

Agilent Pattern generator module for 16700 Series

Figure 5. Unleash thesynergistic power of ahigh-performancelogic analysis systemand oscilloscope withthe E5850A timecorrelation fixture.

Page 7: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

Figure 7. Validatecorrect hardwareoperation by viewingtiming relationshipsbetween multiplebuses and signals.Individually color andsize the signals/busesto highlight anddifferentiate areas ofinterest.

Figure 8. Identifyproblem signalsquickly by using eyescan to make eyediagram measurementson up to hundreds ofsignals simultaneously.

Figure 9. View data patterns and sequences of events from thelisting display which presents data in the same order it wascaptured and placed into memory. The captured binary datacan be inverse assembled into processor mnemonics ordisplayed in multiple formats—binary, hex, decimal, octal,twos complement, ASCII or symbols.

Figure 10. Correlate yourlogic analyzer trace to thehigh-level source codethat produced it. Easilyset up your next logicanalyzer trigger by simplypointing and clicking on aline of source code.

7

Figure 6. The 16700 Seriesprovides the most completeview of your system’s behavior.

3 view & analyze

Page 8: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

8

www.agilent.com/find/la-systems

connect1 2 3acquire view & analyze

Page 9: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

9

12.1-inch (307.34 mm) LCD display with 16702B touchscreen makes it easy to view a largenumber of waveforms or states.

Select a modifiable variable bytouching it, then turn the knob toquickly step through values forthe variable.

Dedicated hot keys give instantaccess to the most frequentlyused menus, displays, and on-line help.

Dedicated knobs for horizontaland vertical scaling and scrolling.Adjust the display to get just theinformation you need to solveyour problem.

“Touch Off” button disables thetouch screen and allows you topoint out anomalies to acolleague without altering thedisplay settings.

Dedicated knobs for globalmarkers help track down toughproblems. A symptom can beseen in one domain (e.g., timing)tied to its cause in anotherdomain (e.g., analog).

Page 10: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

10

System Performance Analysis Serial Analysis

Model No.

Application

Capabilities

B4600B

Optimizing your targetsystem’s performance

Generates statistical bar chart and histograms of

captured data

Shows the amount of timespent in each of the targetedfunctions or data locations

B4601B

Solving your serialcommunication problems

Converts serial bit streamsto parallel format for easy

viewing and analysis

Supports serial data andprotocols that use bit

stuffing to maintain clocksynchronization

Tool Development Kit

B4605B

Customizing the display ofyour acquired data for

greater insight

Creates custom tools toanalyze your data using

C programming language

Source Correlation

B4620B

Correlates the logic analyzertrace with the high-level source

code that produced it

Provides ability to define thecapture event by simply clicking

on a line of source code

Figure 11. Profile your targetsystem's performance to identifysystem bottlenecks and areasneeding optimization.

Logic analyzers with deepmemory can generate largeamounts of acquired data.Analysis of all this data is achallenge without application-specific analysis tools. AgilentTechnologies post-processingtool sets provide powerful data-analysis capabilities that willhelp you gain insight from youracquired logic-analysis datamore quickly and efficiently.These tools expand the power of your Agilent 16700 Serieslogic analysis system by movingbeyond the traditional analysisof timing waveforms and state listings.

• Rapidly consolidate largeamounts of data into displaysthat provide insight into yoursystem’s behavior

• Correlate a logic analyzer tracewith the high-level source codethat produced it

• Profile your target system’sperformance to identify systembottlenecks and isolate areasneeding optimization

Quickly extract valuable informationfrom your trace data

Post-processing Tool Sets

Agilent post-processing tool sets

www.agilent.com/find/la-systems

3 view & analyze

Page 11: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

Figure 12. Enhance yourprotocol debug by viewingtrace information at theprotocol level.

• Display logic-analyzer traceinformation at the protocol level

• Easily trigger on standard orcustom packet header fieldswith powerful trigger macros

• Customize the protocol analysisto your specific proprietaryprotocol using a protocoldescription language

Agilent Technologies protocoltool sets for the 16700 Seriesprovide customized triggeringcapabilities and packet decode.This enables rapid analysis anddebug of industry-standard andproprietary protocols. You’ll gainquick insight into the difficultproblems caused by the use ofserialized and narrow sourcesynchronous buses in high-speedchip-to-chip and backplaneinterconnects.

Faster triggering and viewing of protocol data in a standardized form

Protocol Tools

11

PCI ExpressV1.0,

updated asspec evolves

Serial ATAand ATAPI,

OOBsignaling

(real time) upto 1.5 GHz

RapidIO(8 and 16

bit parallel)

POS PHY L4 (SPI-4.2)

(PPP, ATM,Ethernet, etc.)

GigabitEthernetTBI

Utopia L1-3(ATM),

POS-PHY L1-3(PPP),

MII/GMII(Ethernet),

FlexBus

InfiniBand1x, 4x, 12x

InfiniBand1x, 4x, 12x

MPEG-2

Model No. N4220A N4219A N4215A N4214A N4212A B4640B N4233A N4206A B4645B

PacketTrigger

Yes Yes Yes No No Yes Yes No Yes

AdditionalCapabilities

Real time8b/10b,disparity

error, datadescrambling

CRC/Disparitychecking, datadescrambling,10b capture

mode

CRC/Controlword

checking,real-timeidle filter

Real-timeidle filter

PacketCRC check,8b/10bdisparitycheck

VCRC/ICRC,8b/ 10b,disparity

error,compliance

testing.

VCRC,ICRC, 8b/

10b,disparity

error,compliance

testing.

Packetlengthcheck,packet

CRCcheck

Agilent protocol analysis tool setsfor interconnect standards

3 view & analyze

Page 12: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

12

www.agilent.com/find/la-systems

• Actel• Altera• AMD• Analog Devices• ARM®7/9TDMI• GTE• IBM PPC• IDT• Intel® Pentium®, P4, Xeon

Pentium Pro, II, III, & Celeron™• Motorola• National• NEC• NKK• PACE• QED• Rockwell• Siemens• Texas Instruments• Xilinx• Zilog

• AGP2X, AGP4X, AGP8X• CAN• CSIX• PC 100, PC 133, DDR, DDR 200,

DDR 266, DDR 333, DDR I-400, DDR II,• Fibre Channel• FireWire (IEEE 1394)• Gigabit Ethernet (TBI)• GMII• HyperTransport• I2C• InfiniBand 1X, 4X, 12X• ISA• JTAG (IEEE 1149.1, 1149.5)• MPEG-2• PC 100/ 133 DIMM• PCI CardBus• PCI-EIO• PCI Express• PCI Mezzanine• PCI/EXT-32/64• PCI-X 1.0, 2.0• POS-PHY L1 – L3• Rambus®• RapidIO• RS-232, RS-449• SCSI, Ultra SCSI, SCSI LVD• Serial ATA• SIMM, DIMM• SPI-4.2• USB 1.1, USB 2.0• Utopia• VME 64• VXI• Xilinx: Virtex, Virtex – E, Virtex ll,

Virtex ll Pro, Spartan–ll, Spartan–ll E

• Save time making bus- andprocessor-specificmeasurements with application-specific analysis probes thatquickly and reliably connect toyour device under test

• Support available forcomprehensive list of industry-standard processors and buses

• Display processor mnemonics orbus cycle decode

Agilent Technologies and ourpartners provide an extensiverange of quality tools that offernon-intrusive, full-speed, real-time analysis and processorexecution control to accelerateyour debugging process.

Save time analyzing your unique designwith a turnkey logic analyzer setup

Processor, Bus, and FPGA Support

Agilent and Third-Party Bus,Protocol or FPGA Support

Agilent and Third-PartyProcessor Support

Figure 14. Correlate yourlogic analyzer trace tothe high-level sourcecode that produced it.Easily set up your nextlogic analyzer trace bysimply pointing andclicking on a line ofsource code.

Figure 13. Focus on PCI Expresspackets instead of format details.

3 view & analyze

Page 13: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

13

Emulation ProbesLink to the processor’s debug port for a convenient way to download code, modifymemory and registers, and control program execution.

Model Number

ARM®ARM7TDMI, ARM7DI, ARM710T, ARM720T, ARM740T, ARM9TDMI, ARM920T,ARM922T, ARM925T, ARM940T, ARM946ES, ARM966ES

IBM PPC4XX401 (all), 403 (all), 405 (all), NPe405H, NPe405L, 440A4, 440GP, 440GX

IBM PPC6XX 603, 603e - rev 3, 4, 5, 603ev – rev 2, 12, 603e2, 603P, 603ec, 603R

IBM PPC7XX740, 740L, 740P, 750, 750L, 750P, 750CX, 750CXe, 750FX

MIPSMIPS32-4Kc, MIPS32-4Km, MIPS32-4Kp, MIPS64-5Kc

Motorola MPC6XX603, 603e - rev 3, 4, 5, 603ei, 603ev – rev 2, 12, 603e2, 603P, 603ec, 603R

Motorola MPC7XX740, 740L, 740P, 745, 750, 750L, 750P, 750M, 755

Motorola MPC74XX7400, 7410, 7440, 7441, 7445, 7450, 7451, 7455

Motorola MPC8XX801, 821, 823, 850, 852, 855, 857, 859, 860, 862, 866 families

Motorola MPC82XX8240, 8241, 8245, 8250, 8250A, 8255, 8255A, 8260, 8260A, 8264A, 8265A, 8266A

Motorola M-CoreM2107

E5900B #300

E5900B #060

E5900B #060

E5900B #070

E5900B #200

E5900B #060

E5900B #070

E5900B #110

E5900B #080

E5900B #100

E5900B #090

Add processor execution (run) control and real-time trace capture to best-in-class debuggers

Trace Port Analyzers and Emulation

• Control your processor withbreak, run, reset and single step capabilities

• Download code and modifyregister/memory values

• Trace analysis up to 200 MHz,integrated with industry-standard debuggers

• Xilinx ChipScope Pro with deep external trace andadvanced triggering tools

Agilent Technologies emulationprobes utilize a processor’sdebug port to provide aconvenient way to downloadcode, modify memory andregisters, and control programexecution. Trace port analyzersprovide real-time traceinformation, in addition to thestandard emulation functionality.When integrated with a 16700 Series logic analysis

system,both theemulation probesand trace port analyzers cansupport coordinated systemanalysis of hardware/softwareinteraction for a wide range of industry-standard embedded processors.

Agilent Trace Port Analyzers and Emulation Probes

Trace Port AnalyzersProvides emulation and real-time trace execution information, can be integrated with the16700 Series for coordinated system analysis.

Model Number

ARMARM7/9-ETM

IBM PPC4XX401 (all), 403 (all), 405 (all), NPe405H, NPe405L, 440A4, 440GP, 440GX

XilinxVirtex II, Virtex II Pro, Spartan-II, Spartan-IIE, Spartan-III, Virtex, and Virtex-E

E5904B #300

E5904B #060

E5904B #500

Figure 15. TheAgilent E5904Btrace port analyzer.

3 view & analyze

Page 14: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

14

In Summary

Validation of digital systemscontinues to be a vital piece ofproduct development.Technologies are increasing inspeed and complexity, while R & D budgets, resources andmarket windows are shrinking.These issues make meeting your time-to-market goals more difficult.

Overcome your time-to-marketobstacles with the Agilent 16700 Series logicanalysis systems.

Related Agilent Literature

16700 Series Logic Analysis System, product overview, 5968-9661E

Probing Solutions for Logic Analysis Systems, product overview, 5968-4632E

Processor and Bus Support for Agilent Technologies Logic Analyzers,configuration guide, 5966-4365E

Agilent E5850A Logic Analyzer/Oscilloscope Time Correlation Fixture,photo card, 5988-1684EN

Infiniium 54850 Series Oscilloscopes, Infiniimax 1130 Series Probes, data sheet, 5988-7976EN

Infiniium 54800 Series Oscilloscopes, color brochure, 5988-3788EN

Deep Storage with Xilinx ChipScope Pro and Agilent Technologies FPGATrace Port Analyzer, product overview, 5988-7352EN

PCI Express Tools, color brochure, 5988-7780EN

Signal Integrity Solutions, color brochure, 5988-5405EN

Test Tools for InfiniBand, color brochure, 5988-2424EN

www.agilent.com/find/la-systems

connect1 2 3acquire view & analyze

Agilent 16700 Series

Figure 16. The Agilent 16700 Serieslogic analysis systems help you meetyour time-to-market demands.

Page 15: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

15

Microsoft® is a U.S. registered trademark of Microsoft Corporation.Windows® and MS Windows ® are U.S. registered trademarks of Microsoft Corporation.UNIX® is a registered trademark of the Open Group.Intel® is a U.S. registered trademark and Celeron™ is a U.S. trademark of Intel Corporation.Pentium® is a U.S. registered trademark of Intel Corporation.ARM® is a registered trademark of ARM Limited.Rambus® is a trademark of Rambus Inc.

Page 16: Agilent Technologies 16700B and 16702B Logic Analysis …Agilent Technologies’ 16700 Series logic analysis systems help design teams overcome time-to-market obstacles and meet tough

www.agilent.com/find/la-systems

www.agilent.com

Agilent Technologies’ Test and MeasurementSupport, Services, and AssistanceAgilent Technologies aims to maximize the valueyou receive, while minimizing your risk and prob-lems. We strive to ensure that you get the testand measurement capabilities you paid for andobtain the support you need. Our extensive sup-port resources and services can help you choosethe right Agilent products for your applicationsand apply them successfully. Every instrumentand system we sell has a global warranty.Support is available for at least five years beyondthe production life of the product. Two conceptsunderlie Agilent’s overall support policy: “OurPromise” and “Your Advantage.”

Our PromiseOur Promise means your Agilent test and meas-urement equipment will meet its advertisedperformance and functionality. When you arechoosing new equipment, we will help you withproduct information, including realistic perform-ance specifications and practical recommenda-tions from experienced test engineers. When youreceive your new Agilent equipment, we can helpverify that it works properly and help with initialproduct operation.

Your AdvantageYour Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchaseaccording to your unique technical and businessneeds. Solve problems efficiently and gain a competitive edge by contracting with us forcalibration, extra-cost upgrades, out-of-warrantyrepairs, and onsite education and training, as wellas design, system integration, project management,and other professional engineering services.Experienced Agilent engineers and techniciansworldwide can help you maximize your productivity,optimize the return on investment of your Agilentinstruments and systems, and obtain dependablemeasurement accuracy for the life of those products.

www.agilent.com/find/emailupdatesGet the latest information on the products andapplications you select.

Agilent T&M Software and ConnectivityAgilent’s Test and Measurement software andconnectivity products, solutions and developernetwork allows you to take time out of connect-ing your instruments to your computer with toolsbased on PC standards, so you can focus on yourtasks, not on your connections. Visit www.agilent.com/find/connectivityfor more information.

For more information on AgilentTechnologies’ products, applications orservices, please contact your local Agilentoffice. The complete list is available at:

www.agilent.com/find/contactus

Phone or Fax

United States:(tel) 800 829 4444(fax) 800 829 4433

Canada:(tel) 877 894 4414(fax) 800 746 4866

China:(tel) 800 810 0189(fax) 800 820 2816

Europe:(tel) 31 20 547 2111

Japan:(tel) (81) 426 56 7832(fax) (81) 426 56 7840

Korea:(tel) (080) 769 0800(fax) (080)769 0900

Latin America:(tel) (305) 269 7500

Taiwan:(tel) 0800 047 866 (fax) 0800 286 331

Other Asia Pacific Countries:(tel) (65) 6375 8100 (fax) (65) 6755 0042Email: [email protected] revised: 9/17/04

Product specifications and descriptionsin this document subject to changewithout notice.

© Agilent Technologies, Inc. 2004Printed in USA October 7, 20045988-8435EN

Agilent Email Updates

www.agilent.com/find/agilentdirectQuickly choose and use your testequipment solutions with confidence.

Agilent Direct