Agilent 6820 !"#$% !"# !"!! !"#$%&'() 412 200131 !"#$%&! !"#$%&' 118 ! 16 100022 !"#$%& Agilent 6820 !"#$!" !"#!$%&' !"#!$ (MTBE) ! (ETBE) !" (TAME) ! (DIPE) !!!!!"#$ !"!"#$#%& (DME) !"#$%&'(")*+,-.!,/01 ! !"#$%& !"#$%&'( !"#$%&'()*+,-./01234 ! ! ! !"#$%&' !"#$%&'()*+,%-./ !"#$%&'()*+,-.!"# ! GB17930-1999 !"# 1 !"#$%& 2.7% (m/m) ! 2003 1 1!"#$%&'( !"#$%&'( !"#$%&&'()*+,-./() SH/ T0663-1998 2 !"#$% ASTM D4815 3 ASTM D4815 !"#$%&'%()* ! !"#$%&' / !"#$%&'( ! (FID) Agilent 6820 !"#$%& !"#$% 1,2,3- (2- !) (TCEP) !"#$! HP-1 !"# !"# 1 !"#$%&' !"!"#$%&'()* (G4323A)

Upload: others

Post on 14-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Agilent 6820 · 2017. 5. 31. · James D. McCurry, “Running ASTM Methods D 4815 and D5580 on a Single Agilent 6890N Gas Chromatograph With Nitrogen Carrier Gas”, Printed in the

Agilent 6820�� !"#$%�� !"#

��

��

�� !"�� !�� !

�� !"#$%&'() 412 � 200131

��

�� !"#$%&�� !

�� !"#$%&' 118�� ! 16 � 100022

��

�� !"#$%& Agilent 6820�� !"#$�� !"

�� !"#!$%&'�� !"#!$ (MTBE)��� !

�� (ETBE)��� ! " (TAME)��� ! (DIPE)���

�� �� !�� !�� !�� !�� !"# $�

�� !"�� !"#$#%& (DME)�

��

�� !"#$%&'(")*+,-.!,/01

�� !�� !"#$%&�� !"#$%&'(

�� !"#$%&'()*+,-./01234

�� !�� !�� !�� !"#$%&'��

�� !"#$%&'() *+,%-./��

�� !"#$%&'()*+,-.�� !"#

��� !GB17930-1999�� !"#1�� ��

�� !"#$%&2.7% (m/m)��� !2003�1

�1�� !"#$%&'(�� !"#$%&'(

�� !"#$%&&'()*+,-./() SH/

T0663-1998 2��� !"#$%ASTM D4815 3��

�� ASTM D4815�� !"#$%&'%()*

��

�� !

�� !"#$%&'��/�� !"#$%&'(

�� ! (FID) � Agilent 6820�� !"#$%&

�� !"�#$% 1,2,3- � (2-�� !�) ��

(TCEP) �� !"#$�� !HP-1�� !"#

�� �� !"# 1 �� �� !"#$%&'

�� !"�� !"#$%&'()* (G4323A)�

Page 2: Agilent 6820 · 2017. 5. 31. · James D. McCurry, “Running ASTM Methods D 4815 and D5580 on a Single Agilent 6890N Gas Chromatograph With Nitrogen Carrier Gas”, Printed in the

�� !�

G1180A 6820�� !"# 1

161 �� /�� !"#$%& 1

215 �� !"#$%& 2

302 �� !"#$% 1

751 �� !"# 1

800 �� 1

872 �� 530�� !"# 2

870 �� ! 1

874 �� !"#$%&% 1

335 Cerity NDS ��(��) 1

G4323A �� !"#$%& 1

��

19095Z-123 �� !HP-1 30 m, 0.53 mm, 2.65 m 1�� !"56 cm x 1/16" TCEP(20%) 1

�� !

���� !"

�� !

1��� !"�� ! "#$�� !"#$%�

�� !" TCEP�� !�� !"#$%&

TCEP�� !"#$�� !"#$%&'()

�� !"#$%&�� !"�OFF�����

� 1A��

� 1. �� !

2��� !"#$%&�� !" (DIPE) �� !

��� (MTBE) �� !"#$%�� !�ON�

�� (�� 1B) �� !"#$%&'()*+

�� !HP-1�

3��� !"!# (TAME) �� !"#$%��

�� !"#$%��OFF���� !"#$

� 1. A � OFF � 1. B� ON � 1. C � OFF

TCEP

HP-1

FID

OFF

HP-1

TCEP

FID

TCEP

HP-1

OFFFID

12

3

4

56

7

8

910

12

3

45

67

8

9

10

ON

12

3

4

56

7

8

910

2

Page 3: Agilent 6820 · 2017. 5. 31. · James D. McCurry, “Running ASTM Methods D 4815 and D5580 on a Single Agilent 6890N Gas Chromatograph With Nitrogen Carrier Gas”, Printed in the

�� !"#

�� !"#$%&'()�� !"#$%C5��

�� !"#$%&'()*�� C4�� !"#

�� !"#$%&�� !"�� !"#$%��

�� !"#$%

�� MTBE�DIPE�DME�� !"# (MCP) ��

�� !"#$%&'()*+,&'-�� !"

��0.18�0.34�� �� !"#$%&'(2��

0.22�� �� !"�� !"#�� TCEP��

���� !"#$%&�� MTBET �DIPE��

�DIPE�� !"#�� !"#$%&'0.28��

�� !"# Cerity NDS�� !"#

�� ! 0.22�� �� MTBE�DIPE�� !�0.22�� ���� !"#$%&'��� TCEP�� !"� MTBE�DIPE ��� TCEP��

�� Agilent 6820

�� !"#$%& Cerity NDS

�� �� /�� !"#200���� !15:1

�� FID�250���� N2�18 mL/min

�� 60��(6 min)�2�/min�75��5�/min�115�

�� 60�

�� !" N2, 3 mL/min

�� !"# N2, 3.5 mL/min

�� ! 350 mL/min

�� ! 40 mL/min

�� ! 0.21 min 1

�� ! TCEP�� !"� 560 mm��� 1.6 mm��� 0.38 mm

�� HP-1�30 m�0.53 mm�2.65 m

� 1��� !"#$%&'()*+

� 2. �� !"#

� DIPE�� !"�� !"#$% 0.28�� �0.28�� MTBE�� !TCEP����� ! DIPE �� TCEP ��

�� !

�� !"# 2��

�� ! ��

��

(Are

a)

Area, MTBE/DME

Area, DME/DME

Area, DIPE/DME

Area, MCP/DEM

3.5

3

2.5

2

1.5

1

0.5

0

0.18 0.2 0.22 0.24 0.28 0.3 0.32 0.34

3

Page 4: Agilent 6820 · 2017. 5. 31. · James D. McCurry, “Running ASTM Methods D 4815 and D5580 on a Single Agilent 6890N Gas Chromatograph With Nitrogen Carrier Gas”, Printed in the

��

�� !"#$%&'()*�� !"#$%&'

�� !"#$0.1�0.5�2�5�10�15�20% (m/m)

�� !"#$%�� !"#$�� !�� !"

�� ! /�� !"#��Y���� �� !"

�� !/�� !"#��X�� !"#$%&'

�� !"#

�� !"

�� !

�� !"#$%&'()*+�,-%)./��

�� !"#0.999�� !"#$�2�� !"#

�� !�� !"#$%&'()

�� !"#$%&'�� !Y�� bi�� !"

�� !"#$�� !"#$�wi��0.1% (m/m)

��Ai�� ! 0�Y�� !"#$%�&'()

wi = (bi/mi)�(ws/wg)� 100-----------(1)

�� wi�� !"# i�� !"#$ASTM4815�

�� !wi�� 0.1% (m/m)�

ws�� !"#$%&'()g�

wg�� !"#$g�

��2�� !"#bi=0.0028�mi=1.9754��� !

�� !"#$%&' 0.5 mL �� (ws=0.4 g) � 9.5

mL �� (wg=7 g)��� !"#$ (1) �� !

wi=(0.0028/1.9754)�(0.4g/7g)� 100=0.008% (m/m)

wi=0.008% (m/m) ��� 0.1% (m/m)��� !"

����bi�� !"#$%&�� !"#$%&'

�� !"#$%wi�� 0.1% (m/m)�

� 2. �� !"#$%

�� !�� / �� (�� �!")

�� !"#��

/�

3.5

3

2.5

2

1.5

1

0.5

00 0.5 1 1.5 2

y = 1.975x + 0.0028R2 = 1

4

Page 5: Agilent 6820 · 2017. 5. 31. · James D. McCurry, “Running ASTM Methods D 4815 and D5580 on a Single Agilent 6890N Gas Chromatograph With Nitrogen Carrier Gas”, Printed in the

�� !"#$%&'

�3�� !"�� !" #$%&'(13�� �

�� !"#$%&�'(

� 4�� !"#$%&�� !"#$%&'()

���� !"#$ASTMD4815 (� SH/T0663) �

��

1. ��

2. ��

3. �� 4. �� 5. �� 6. �� ! ��

7. �� 8. �� ! 9. �� 10. �� 11. �� � �� 12. �� 13. �� !"14. ��

� 3. ���� !"#$%!&'()

n

4500

4000

3500

3000

2500

2000

1500

1000

500

0

�� �� ! (5�� ) ASTMD4815 (� SH/T0663) �� !"

�� !% (m/m) �� ��

�� 7.974 0.225 0.09(X0.59) = 0.306

�� 0.539 0.026 0.06(X0.61) = 0.041

�� 7.958 0.012 0.04(X0.56) = 0.128

�� 0.491 0.023 0.04(X0.56) = 0.027

�� 5.008 0.033 0.03(X0.57) = 0.075

�� 2.008 0.004 0.03(X0.61) = 0.046

�� 1.996 0.008 0.08(X0.56) = 0.119

�� 1.851 0.015 0.04(X0.61) = 0.058

�� 0.488 0.004 0.06(X0.61) = 0.039

�� !�" 0.499 0.031 0.05(X0.56) = 0.034

�� !" 1.867 0.021 0.08(X0.56) = 0.114

�� ! " 16.668 0.278 0.05(X0.70) = 0.358

��X�� !"#!$%&'()

�� !�� !"#$��%&'()�*+,-./-0123 !4567*89:;<=>4?@AB1CDEFGHI:�J�SH/T0663��� !"#$%&'()*+�� !"#)

5

0 2 4 6 8 10 12 14 16 min

� 4. �� !"

Cerity NDS

Cerity NDS�� !"#$%&'()*+�� !

�� !��"#$%&'()*+,-./��

�� !"#$ Cerity NDS�� !"#$%

1

2

3

4

5

6

78

910

11

12

13

14

Page 6: Agilent 6820 · 2017. 5. 31. · James D. McCurry, “Running ASTM Methods D 4815 and D5580 on a Single Agilent 6890N Gas Chromatograph With Nitrogen Carrier Gas”, Printed in the

www.agilent.com/chem

�� !"#$%&'()*+,-.�� !"�� !"#$%&'()*+,-./

��

�� !"#$�� !"#$%&'�� !"#$

©�� !"#$%&'()2004 �

�� !

2004 � 6 � 1 �

5989-1337CHCN

��

�� Agilent 6820�� !" (GC) �� !"#$

�� !"�� !"#$%�� !ASTM D4815

�� !"#$%&'%(�� !"#$%&��

�� !"#$%&'Cerity NDS�� !"#$%�

�� !"#$�� !"�� !"#$%&'()

�� 0.999�� �� !"#$%&'()*+"

���� !"#$%ASTM D4815���� !"

�� !"#$%&'() SH/T0663��� !

�� !

1. �� !"#$$%&'GB17930-1999�� !

��

2. �� !"#$%&'()*+,SH/T0663-1998

�� !"#$%&$'()(�� !")

3. ASTM D4815 Standard Test Method for

Determination of MTBE, TAME, DIPE, tertiary-

Amyl Alcohol and C1-C4 Alcohols in Gasoline by

Gas Chromoatography

4. James D. McCurry, “Running ASTM Methods D

4815 and D5580 on a Single Agilent 6890N Gas

Chromatograph With Nitrogen Carrier Gas”,

Printed in the USA March 17, 2003 5988-9153EN