Confidential Agile Solution for Data Center Lynx2-customfit™ Connector

Upload: others

Post on 26-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

ConfidentialConfidential

Agile Solution for Data CenterLynx2-customfit™ Connector

Page 2: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Problems atthe Data CenterConventional Pigtail Solutions present issues at every step of the installation.

Page 3: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Problems at the Data Center

On-Site

Difficult cable installation

Handling of excess length

Rack space

Urgent maintenance

Management

Time consuming pre-survey

Ordering process

Delivery lead time

Stock management

Page 4: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Solutions atthe Data CenterCustom solutions which prove massive efficiencies across stock management, cabling, maintenance, and manufacturing.

Page 5: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Solutions at the Data Center

On-Site

Plug head less Cable laying

Just Length

Rack space saving

Quick recovery

Management

No Pre-survey

No Patch cord Design

Time saving

Simple stock management

Page 6: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

First, It StartsWith Smooth Cable

Installation

Page 7: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

No Pre-Survey and Cabling Design

Conventional Pigtail Cabling

Lynx-customfit™ Solution

1.Survey 2.Measure 3.Design

Just prepare Lynx connectors and bulk cables, and immediately start!

Troublesome order procedureor you have to have many SKU in stock

4.Order 5.Deliver

6.Installation

1.Installation

Survey Measure Design Order Deliver

Page 8: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Slackless Cable Management

Conventional Plug & Play Solution

Lynx2-customfit®

Solution

Chaotic routing due to use of fixed length pre-terminated cords

Slackless cable managementwith Lynx connectors

Page 9: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Rack Space Saving (Depth)

ConventionalPigtail Solution

Lynx2-customfit®

Solution

Conventional tray with splice tray Shallow panel withoutsplicing tray applicable

Lynx does notneed splicingtray so the panelcan be smaller

This much shortened

This is panelfor conventional pigtail solution

It needs spacefor splicing tray

Tray

Page 10: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Rack Space Saving (Vertical)

ConventionalPigtail Solution

Lynx2-customfit®

Solution

Conventional tray with splice tray Shallow panel withoutsplicing tray applicable

Pigtail Excess Length use 1U space for slack management

1U tray necessary space saved

We can place 1 morepatching panel in this case

Page 11: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Urgent Maintenance(In Case of No Inventory)

Conventional Plug & Play Cabling

Lynx-customfit™ Solution

Just prepare Lynxconnectors and replace only one connector immediately!

If only one connector end is dysfunction, you have to replace all of the cable.

Only One is NG

Diagnose Order Deliver

Replace all

Quick Recovery

Page 12: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Stock Management

ConventionalPigtail Cabling

Lynx2-customfit™

Solution

Need to have various kinds of SKU Occupy stock yard

Just stock Lynx connectorsand bulk cables

Less stock space required

100pcs of connectors can bestored in one cardboard box

Page 13: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Manufacturing

Cable cut, removing sheath

Termination, UV curing(Curing time: approx 1 hour)

Polish

12pcs/lot30min/lot

Assembly3min/pc

Inspection and packing

0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30

Conventional Method

Lynx-customfit™ Solution

Longer production lead time

Skilled operatorsare required

Consumablesare expensive

72c Trunk Cable, 12 x MPO/Cable

Shorter production lead time

Lower initial investment

Skilled operators not required

0:00 0:30 1:00 1:30 2:00

Cable cut, removing sheath

Fusion splicing, assembly6min/pc x 12pcs

Inspectionand packing

72c Trunk Cable, 12 x MPO/Cable

Page 14: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Problemsat Data Center:

Conventional Lynx

Difficult Cable Installation

Handling of Excess Length

Rack Space

Urgent Maintenance

Time Consuming pre-survey

Ordering Process

Delivery Lead time

Stock Management

Summary: Lynx Customfit™

Solves Your Problems

Page 15: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Lynx2 Customfit™

Field Assembly Splice-on-connector

Cord PreprocessingSTEP 1

Remove and slit the cord sheath using the Lynx strip & slit tool.

Remove the buffer and cleave the fiber.

Page 16: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Lynx2 Customfit™Field Assembly Splice-on-connector

Fusion SplicingSTEP 2

Set the fiber holder with the cord on the left side.

Set the ferrule intothe holder and placeit on the right side.

Close the wind hood and start the splice.

Move the spliced assembly intothe oven andstart heating.

Page 17: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Lynx2 Customfit™

Field Assembly Splice-on-connector

AssemblySTEP 3

After the heating, remove the connector from the oven.

While rotating the rear housing, gripthe Kevlar® strands.

Remove thedust cap.

Finished andready to use.

Page 18: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

A New Cabling Experience at

your Datacenter

Page 19: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

ConfidentialConfidential

Reference

Page 20: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Lynx2 Customfit™Field assembly splice-on-connector

Adapting splicing technology, Lynx provide highly reliable optical connector on site. Optimize the cable length as exact length, Lynx solves cable snarl, slack in the floor, trays, and racks, moreover improves air-conditioning efficiency.

Page 21: Agile Solution for Data Center Lynx2-customfit …global-sei.com/sumitomo-electric-splicers/products/lynx2...0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 Conventional Method Lynx-customfit

Confidential

©2016 Sumitomo Electric Industries, Ltd. All Rights Reserved

Lineup and Specification

Bare Ribbon Ribbon Cord 3mm Round CordFCLCSC ST

Full Line up for all needs