afc gate functional desc (operation)
DESCRIPTION
Opeartion of AFC gates in DMRCTRANSCRIPT
FUNCTIONAL DESCRIPTION
Equipment which controls the access of patrons from free area to paid area & vice versa according to business rules.
Made of a stainless steel housing.
Passenger comes in free area to purchase ticket for desired station or uses CSC.
Token issued with Zone, date,time, tom no. and station ID marked on it.
One ticket for RJCK please
Here is your token
Shows his token or CSC at Gate SMV on free area
SMV reads the token and writes Entry date,time, equipment id and station id on token or CSC
Upon reaching destination station passenger shows his token to Gate SMA on paid area.
Token is read and if found valid I.e. for time and Zone allows exit by accepting the token and opening flap
Otherwise display error message.
AFC GATE EXTERNAL VIEW
Gate aisle is formed be two gate cabinets placed next to each other
An aisle is the normal way to enter or exit to or from paid area of a station
The two gate cabinets work together to provide the required functionality
Standard middleStandard endStandard end wideStandard hybrid wideLength 1900 mm,Width 280 mm,Height
1020 mmNormal gate spacing is 550 mmWide gate spacing is 900 mm
ENTRYEXITBIDIRECTIONAL
NORMALHYBRID/WIDE
Presentation of media to SMA/SMV.Reader reads it.PID informs passenger.Validation or error tone from LS.Flap opens and passenger passes through
sensors.Passenger detection.Gate records the transaction and upload it.
• Performed through a set of 16 couples of optocells (emitter/receiver)
• Passage is split into following four zones according to sensor placement
1. Detection zone
2. Surveillance zone
3. Safety zone
4. Exit zone
In-Service : In this mode Gate can function as Entry/exit or
reversible gateMode set by: SC, GRCU, Local command from
maintenance menu of GatePID, GED and CSC R/W work according to
mode set
Out Of Service : In this mode Gate remains blocked for Entry
as well as Exit.Media validating devices are off.Mode set by: SC, GRCU, Local command from
maintenance menu of Gate.GED shows Red cross and PID displays Out of
Service.
Out Of Order : In this mode Gate remains blocked for Entry
as well as Exit.Media validating devices are off.Mode set by a fatal failure detected by the
Gate itself
Maintenance: In this mode Gate remains blocked for Entry
as well as Exit.Media validating devices are off.PID displays maintenance information to
operatorSet locally from Gate itself
Station Closed : In this mode Gate remains blocked for Entry
only.Media validating devices from Exit side work.Mode set by: SC, GRCU, Gate locally from
Maintenance menu
Emergency Open : Gate flaps open immediatelyPID display Emergency exit messagePassengers can walk freely through aisle
without ticketMode set by: SC, GRCUHas highest priority over all other 5 modes
Normal : Every entry is to be followed by an exit. Cycle has to be completed.Exit without proper entry or entry without proper exit not given.
Entry/Exit Override: Entry/exit check is disabled and multiple entry or exit provided on same ticket
Time Mode Override: Time check is disabledIncident: Exit allowed with valid tickets but fare
not detected from CSC and CST not accepted at SMA.
Fare mode set by: SC, GRCU, Gate maintenance mode
To change or view any configuration on Gate, it is necessary to enter maintenance mode
Operator has to open gate door and access the keypad.
Door opens and gate goes out of servicePress 123 to go to maintenance AccessEnter your PIN no. to access Maintenance
Menu