aeroqual aqy 1 · new global hq in auckland, new zealand #1. most innovative product, nz high tech...
TRANSCRIPT
Aeroqual AQY 1micro air quality monitoring system
Our Vision
2
To make air quality information relevant to people wherever they live, work, and play.
Aeroqual in Numbers
2001Founded by Prof.David Williams and Dr Geoff Henshaw
10,000More than 10,000 instruments in use around the world
2017New global HQ in Auckland, New Zealand
#1Most Innovative
Product, NZ High Tech Awards 2016
7Patents covering sensor fabrication, instrument design
1,000No. of cities we have successfully delivered projects in
3
U.S. EPA R&D Collaboration
• 5-year Cooperative Research and Development Agreement signed late 2017 between U.S. EPA and Aeroqual official announcement
• Objective: to accelerate new applications, methods and technologies for low-cost air quality monitoring
• Aeroqual – contribute air sensor technology, application expertise, and data interpretation experience
• U.S. EPA – provide air monitoring infrastructure and air pollution measurement capabilities
• Location: U.S. EPA Ambient Monitoring Innovative Research Station (AIRS) in Research Triangle Park, North Carolina, USA
4
Our Customers
5
Product AQM 65Air Quality Station AQS 1 Dust Sentry
Dust Sentry ProAQY 1
Micro StationPortable
Air Monitors
Measurement Parameters
PM10, PM2.5, PM1, TSP, NO2, CO, O3, SO2, NOx, VOC, H2S, CO2,
NH3,Meteorological, Noise
PM10, PM2.5, PM1, TSP, VOC, NO2, O3,
Meteorological, Noise
PM10, PM2.5, PM1, TSP, Meteorological, Noise
PM2.5, NO2, O3, Temp, RH
PM10, PM2.5, NO2, CO, O3, SO2, VOC, H2S, CO2, NH3, CH4, Cl2,
Temp, RH
User Configurable Yes Yes Yes No Yes
Power Supply Mains recommended Mains, solar, battery Mains, solar, battery Mains, solar, battery Mains, solar, battery
Operating Range -35°C to +50°C -10°C to +45°C -10°C to +50°C -10°C to +40°C 0°C to +40°C
IP Rating IP65 IP65 IP65 IP33 IP31
Weight <50KG <13KG <13KG <1KG <1KG
Design Life - System- Sensors
10 years2 yrs (gas) to 5+ yrs (PM)
10 years2 yrs (gas) to 5+ yrs (PM)
10 years5+ years (PM)
5 years1 to 2 years
5 years1 to 3 years
Sampling Method Pump Pump Pump Fan / Diffusion Fan / Diffusion
Calibration Pre-shipment, Field (certified gas)
Pre-shipment, Field (certified gas)
Pre-shipment, Field (co-location)
Pre-shipment,Field (co-location)
Pre-shipment, Factory / Lab
Approvals MCERTS, FCC, CE MCERTS, Rule 1466, FCC, CE MCERTS, Rule 1466, FCC, CE FCC, CE FCC, CE
Typical Data Quality ★★★★★ ★★★★ ★★★★ ★★★ ★★
Maintenance Cost % of purchase price 20% p.a. 20% p.a. 10% p.a. 15% p.a. 10% p.a.
*all information indicative only, subject to change without notice
Our Products
AQY 1A ‘low cost’ micro air quality monitor that produces scientifically credibledata, yet is simple to set up and easy to use.
“The Aeroqual AQY multi-sensor units performed very well compared to more expensive FEM/FRM instruments and overall showed excellent correlation for ozone, and very good correlation and high accuracy for NO2 and PM2.5.”
- AQ-SPEC: Air Quality Sensor Performance Evaluation Center
7
AQY roadmap
Developed under a multi-year R&D project funded by NZ government
Field tested in NZ, US and China
Designed to give indicative measurement of key pollutants at
an affordable price point
Available for pilot scale evaluation. 100 node network in Los Angeles.
Commercial release of full production version 1 June 2018
2015
2016
2017
2018
8
Smart city grid networks Roadside traffic emissions
Emergency response / event monitoring
Community groups / citizen science
Schools and childcare health and safety
Community exposure studies
Mapping smog formation and distribution
Validation of air quality models
AQY – applications
9
AQY 1 specifications
Parameters O3, NO2, PM2.5, Temp, RH, dew pointPower User supplied 12V DC plug pack, 24WDimensions 215H x 170W x 125D mmCalibration Factory calibration, remote calibration
optionalOn-board PC 1.2GHz quad-core, 1GB SDRAM, 16GB
SDHC Storage, Debian OSData logging Unlimited Aeroqual Cloud data
storage, 32 GB Memory stick backupComm’s WIFI, cellularSoftware Aeroqual Connect / Cloud, API
For complete specifications please use the following link.10
AQY – API
• Access the API on our cloud servers (AWS)
• Rest API - use any programming language that supports HTTP requests/replies with cookies
• Supports up to one API call per second per username
• Through the API you can: • Get a list of devices,
• Get data for each of those devices
• Get and set settings for those devices
• Full details on the API available HERE.
11
Aeroqual Care
Aeroqual Connect and Cloud software licenses
Secure data storage and backup to third party servers
Remote technical support
Free upgrades to the latest sensor algorithms
Discounts on replacement sensors and spare parts
Get sent automatic alerts on device diagnostics
Aeroqual’s support plan – two years included with purchase of the device
12
Maintenance & Servicing
• AQY intended to be ‘no touch’ for 12 months+
• Sensor life is key determinant of unscheduled maintenance; it varies by level of PM pollution*
• When sensor fails, an alert is sent, and standard operating procedure is to:
• Return whole device to base
• Replace failed sensors (simple mechanical process)
• Return device to field.
• Annual maintenance ~15% of purchase cost typical.
*sensor life ~12months based on 0-50 μg/m3 annual average PM10 13
Independent test
AQ-SPEC was set up by South Coast AQMD in Los Angeles to provide independent testing of low-cost air quality sensing devices. All manufacturers are invited to send devices for testing. Results are made publically available on the AQ-SPEC website.
AQ-SPEC’s summary report on the AQY:• Minimal down-time: data recovery from each unit was higher than 90% • Low intra-model variability for all measured pollutants • Ozone sensors showed excellent correlation with a more expensive FEM
instrument (R2 > 0.95) • NO2 V2 sensors showed very good correlation with a more expensive FRM
instrument (R2 > 0.74) and high accuracy • PM2.5 sensors showed very good correlation with more expensive FEM
instruments (GRIMM: R2 > 0.84 and BAM: R2 > 0.83) and high accuracy• Temperature and relative humidity sensors showed excellent correlation with the
SCAQMD Met Station sensors (T: R2 > 0.91 and RH: R2 > 0.94)
Full report available here. 14
AQY – unique technology• O3 sensor uses Aeroqual’s patented gas sensitive semiconductor
(GSS) for unrivalled sensitivity, stability and selectivity
• NO2 sensor combines patented algorithms with our O3 sensor to eliminate cross interferences common to other ‘NO2’ sensors
• Automatic baseline correction (ABC) modulates between sample and zero flow conditions to remove diurnal and seasonal temperature and humidity effects
• Light-scattering optical particle sensor has algorithms for humidity and temperature compensation, and an anti-static inlet
• 1 part-per-billion (ppb) detection of O3 and NO2.
15
AQY vs other low cost monitors
• Advanced measurement techniques – not off the shelf sensors
• All measurement is done on the device – many other devices rely on data processing in the cloud before outputting a measurement
• Unlimited Aeroqual Cloud data storage, allowing for fail-safe back-up
• Aeroqual Cloud is used for data acquisition and display and remote diagnostics. Software is bundled with the instrument providing a complete product package
• Product is backed by a decade of field experience deploying and supporting sensor-based instruments in a wide range of outdoor ambient applications.
16
• 100 AQY devices deployed across Los Angeles in partnership with South Coast Air Quality Management District (SC AQMD) and UCLA
• Funding provided through EPA Star Grant and NZ Government R&D funding
• First 25 units have been operational since Dec 2017, network complete by March 2018
• SC AQMD is under pressure to show progress towards rule AB617 a state law that requires ‘community-level’ air quality monitoring.
Los Angeles AQY network
17
LA – device locations
Downtown - Port
Riverside
Imperial County
18
• SC AQMD has access to the data via API for their own analysis
• Citizens and schools are logging in via Aeroqual Cloud
• Aeroqual is applying third party software tools to analyse and visualise the data
• A richer picture is emerging of PM2.5, O3, and NO2 patterns in the region.
LA – data flows
19
• Itron (ITRI: NASDAQ) is a leading provider of smart meters and networks for utilities and cities
• Aeroqual partnered with Silver Spring Networks, acquired by Itron early 2018
• Aeroqual has integrated Silver Spring Network’s mesh radio, enabling two-way communication over the network
• AQY units are installed on smart lights that operate on Itron’s network
• Demonstration projects established in San Antonio, New Orleans, and Chicago
Smart Cities Case Study
20
Aeroqual Limited460 Rosebank Rd, Avondale, Auckland, New Zealand
t. +64 9 623 3013e. [email protected]
www.aeroqual.com
Keep in touch
MRK-D-0523© Aeroqual Ltd, 2020 All rights reserved