advances in veneer dryer moisture sensing &...

13
Drying Technology, Inc. Advances in Veneer Dryer Moisture Sensing & Control John Robinson & Roger Douglas Drying Technology, Inc. 409-385-6422 www.moisturecontrols.com [email protected]

Upload: others

Post on 02-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Advances in Veneer Dryer Moisture Sensing & Control

John Robinson & Roger Douglas Drying Technology, Inc.

409-385-6422 www.moisturecontrols.com [email protected]

Page 2: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Control Veneer Moisture Rather than % Redry

Goals Maximize Veneer Production Rates

Improve Veneer Quality Increase Veneer Recovery

Lower Glue Usage

Since these goals depend on Veneer Moisture Control Veneer Moisture Rather than % Redry

How do we accomplish that?

Page 3: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Problems with Redry-based Veneer Dryer Control (Long lag time & control of wrong variable)

Feed

6 Min 11 Min

Dead Times

Veneer Dryer

Lag time ∝ Std Dev

Down Stream Moisture Meter

(50 sheet Average)

Page 4: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Exclusive Delta T Model Features That Significantly Improves Veneer Dryer Control

MC = K1(ΔT)p – K2/Sq

An Inside-the-dryer Moisture Sensor

Capability for calculating new setpoint

Page 5: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Feed

Sensor Location

Down Stream Moisture Meter

4.8 Min

6 Min 11 Min

Less Dead Time than Moisture Meter

Dead Times

Dryer

Less Variance than With Moisture Meter Control

Dead time ∝ Std Dev

(50 sheet Average)

Replace % Redry Control with Delta T Inside-the-Dryer MC Sensing & Control

Page 6: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Inside-the-Dryer Moisture Sensor (Solves Lag time Problem)

MC ≈ ΔT

Page 7: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Old ∆T SP

Evaporative Load Increase

New ∆T SP

Actual ∆T Value

Delta T Calculates New Set Point That Maintains Target MC

Page 8: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Improved Veneer Dryer Controls Veneer Moisture not Redry

Delta T Set Point

Delta T Controller Dryer

Delta T Inner (Fast) Loop

Moisture Set Point

Moisture Middle (Slow) Loop

Redry Set Point

Redry Outer (Slower) Loop

Page 9: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Delta T Enables Veneer MC to be Shifted From 10.0% to 10.9%

Delta T Control

Current Control

Same Mean Moisture Production Increase Reduction in Energy

Increase Mean Moisture

M1 M

MC UCL

Page 10: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Typical Veneer Drying Curve

Page 11: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Increase Production Rate By Improved Moisture Control

Page 12: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Synergistic Effect of Air Content on Driving Force for Veneer Drying

Page 13: Advances in Veneer Dryer Moisture Sensing & Controlpelice-expo.com/presentations/Robinson-Veneer-Dryer-Control.pdfProblems with Redry-based Veneer Dryer Control (Long lag time & control

Drying Technology, Inc.

Potential Savings Provided by Delta T

Normal use of Delta T 7.0%

Increase veneer moisture of 0.9% 4.5%

Monitoring & operating at optimum air content 3.6%

Glue Savings from Increase in MC $$

Quality Improvement