advanced technology laser co., ltd. a leading manufacturer of light based devices for medical and...
TRANSCRIPT
Advanced Technology Laser Co., Ltd.Advanced Technology Laser Co., Ltd.
A leading manufacturer of light based devices for medical and cosmetic applications
Angelite-SDC
Angelite-SDC system is designed from the ground up for effective hair removal, skin rejuvenation, pigmented and vascular lesions treatment.
General Information Advanced Technology Selecting Parameters Entering Parameters Advantages Before and After Photos
Specifications
Wavelength(nm)
Fluence(J/cm2)
Pulse Duration(ms)
Frequency(Hz)
Spot Size Cooling System
560-1200700-1200400-700
525-1200
3-45 4-512 1, 1/2, 1/3 10.8mm×45.8mmIntegrated Pyro-electric Contact
Cooling
Indications for use
Hair Removal Skin Rejuvenation Vascular and Pigmented Lesions: pigmented spots and
telangiectasia, etc..
Skin Type
Recent sun exposure in treatment area• May affect maximum safe fluence
Determine skin type using the Fitzpatrick Scale
I II III IV V VI
White White White - Light Brown
Light Brown - Olive
Moderate - Dark Brown
Black
Burns easily, never tans
Burns easily, tans minimally with difficulty
Burns moderately; tans moderately and uniformly
Burns minimally, tans easily and
moderately
Rarely burns; tans profusely
Never burns; tans profusely
General Information Advanced Technology Selecting Parameters Entering Parameters Advantages Before and After Photos
IPL Technology
Intense pulsed light technology involves application of a non-laser, broadband and filtered flashlamp source directed to the skin. Modification of various parameters allows flexibility in treatment. These include but are not limited to wavelength, fluence, spot size, pulse duration, pulse delay, pulse number and frequency.
IPL technology removes age spots (sun-induced freckles), most benign brown pigments, and redness caused by broken capillaries through a process called photorejuvenation for face and body.
The gentle, non-ablative treatments use broad spectrum light to treat the face, chest, neck and hands—virtually anywhere that sun damage shows.
Pulse Control Pulses and Sub-pulses
Adjustable sub-pulse number (1-12) Adjustable sub-pulse delay(5ms-40ms) Adjustable sub-pulse width(4ms, 5ms, 6ms)
Energy depends on charging voltage and sub-pulse numbers
Integrated Pyro-electric Contact Cooling system
Integrated Pyro-electric Contact Cooling (PCC)
Variable Synchronized Pulse Control (VPSC) For Clinical Efficacy & Safety
Integrated Pyro-electric Contact Cooling system
Two handpieces
Just a simple press , you can easily change handpiece
ESP Technology
ESP handpiece:
Easy--- Switch on and off easily
Smart---Identifying handpiece type, recording pulse numbers and guaranteeing energy output (fluctuation: ±5%)
Powerful---Maximum energy is up to 225J
Ergonomics of handpiece
General Information Advanced Technology Selecting Parameters Entering Parameters Advantages Before and After Photos
Wavelength
Selecting Parameters –Wavelength
Wavelength
Wavelength Applications
400-700nm Treat mild to moderate acne
525-1200nm Photo rejuvenation for multi-skin types
560-1200nm Remove pigmented and vascular lesions/ skin rejuvenations
700-1200nm Hair removal for all kinds of skin and different body areas
Cycle
Selecting Parameters –Cycle
Cycle: The interval between two pulses Determines speed to glide the handpiece Does not affect amount of light delivered (fluence) with each
pulse Increase in cycle value = decrease in treatment speed Based on:
• Treatment area
• Patient comfort
• Operator level of expertise
Start with a high cycle value (3s) to gain experience prior to using lower one.
Spot Size
Selecting Parameters – Fixed Parameters
Spot Size
Fixed: 10.8mm×45.8mmm
Large spot size(10.8mm×45.8mm) makes Angelite-SDC treatment speed faster than competitive systems ; Large spot size increases the penetration depth. It can treat deeper targets.
Sub-Pulse Number/Width/Delay
Selecting Parameters – Sub-Pulse Number/Width/Delay
Sub-pulse number Adjustable from 1 to 12;
Sub-pulse width
Adjustable: 4ms, 5ms, 6ms
Sub-pulse delay Adjustable from 5ms to 40ms. Pulse Width=(sub-pulse width)×(sub-pulse number)+(sub-pulse interval) ×(sub-pulse number-1)
• Pulse width based on thickness of hair– Bigger target = longer pulse width
» coarse, dense hair (i.e., beard, bikini)– Smaller target = shorter pulse width
» fine hair, sparse distribution
• Pulse width Based on skin type– Increase for darker skin types
Selecting Parameters – Pulse Duration
Pulse Duration
4ms-512ms
Treat small vessels & fine hair, etc. Treat coarse hair and
leg veins, etc.
Angelite-SDC offers wider range pulse duration, from 4ms to 512ms, which safely and effectively treat all skin types including tanned skin and the broadest range of hair colors, diameters and depths.
Fluence
Fluence =
Fluence selecting is based on skin type, hair color and density, and epidermal response;
Begin at a low setting, and do a test area treatment;Areas with dark skin or high hair density and/or coarse dark hairs (such
as the chin) should be treated at lower fluences than areas with lighter
skin or sparser hair.
energy of entire laser pulse (J)
area of light beam where it strikes the skin (cm²)
Selecting Parameters – Fluence
Selecting Parameters – Fluence continued
Fluence
Max: 45J/cm2(
More effective treatment with high fluence
Remarks:•PL, Cynosure and IPL, Lumenis One : Fluence limitation with larger spot sizes; (Cynosure---minimum spot size: 10mm×21mm, maxmum fluence: 30J/cm2); (Lumenis One--- minimum spot size: 8mm×15mm, maxmum fluence: 40J/cm2)•OPS, Cutera and Harmony, Alma: Low fluence( no more than 20J/cm2) can not treat light skin and fine hair efficiently
Angelite SDC Clinical Parameters
Benign pigmented lesions (560~1200nm )
Skin type Pulse No. Pulse width (ms) Pulse Delay (ms) Fluence (J/cm2) Cycle (s)
I, II 4~6 5~6 15~20 14~20 2
III, IV 3~4 5~6 15~20 10~16 2
Benign vascular lesions (560~1200nm )
Skin type Pulse No. Pulse width (ms) Pulse Delay (ms) Fluence (J/cm2) Cycle (s)
I, II 5-7 4-6 10~20 15~25 3
Ⅲ,Ⅳ 4-6 4-6 15~30 13~22 3
Hair removal (700~1200nm)
Skin type Pulse No. Pulse width (ms) Pulse Delay (ms) Fluence (J/cm2) Cycle (s)
I, II 4~8 4~5 15 14-18 2
III, IV 3~7 5~6 20~30 10-15 2
IV, V 15 5~6 20~30 8-12 2
Acne (400~700nm)
Skin type Pulse No. Pulse width (ms) Pulse Delay (ms) Fluence (J/cm2) Cycle (s)
I, II 4~6 4~5 15 14-18 2
III, IV 3~4 4~5 20 10-12 2
IV, V 2 4 30 8-10 2
Remarks: The above clinical parameters and setting is only a
reference for treatment; It is best that the areas to be treated were covered with a
layer thin cooled transparent hydro-gel before treatments; The actual setting lies on doctor’s experience, the skin type
and sensitivity of patient, and tightness that therapeutic crystal press the skin;
Darker skin needs lower energy density; More tightly the therapeutic crystal press the skin, lower
energy density is set.
General Information Advanced Technology Selecting Parameters Entering Parameters Advantages Before and After Photos
Entering Parameters – Controls
Control locations on display screen
Fluence
Change handpiece
Subpulse Number
Subpulse Width
Subpulse interval
Interval between two pulses
Entering Parameters – Indicators
Indicator locations on display screen
Pulse Counter---right handpiece
Pulse Counter---left handpiece
General Information Advanced Technology Selecting Parameters Entering Parameters Advantages Before and After Photos
Advantages
SDC has large spot size for more effective treatments; SDC is extremely powerful---large spot size with high
fluence; SDC uses ESP advanced technology to make the
handpieces Easy to use, Smart to connect, and Powerful SDC uses Integrated Pyro-electric Contact Cooling to
provide maximum safety and comfort to patients; SDC allows you to treat ALL skin types safely and
effectively.
General Information Advanced Technology Selecting Parameters Entering Parameters Advantages Before and After Photos
ATL copyrightBefore
ATL copyrightAfter(3 times treatment)
Skin Rejuvenation
Freckles
ATL CopyrightATL Copyright
AfterBefore After (3 times treatment)
Telangiectasia
BeforeAfter (3 times treatment)
Telangiectasia
Before After (4 times treatment)
After (2 times treatment)
ATL copyrightATL copyrightBefore
Hair Removal
Hair Removal
ATL copyrightBefore
ATL copyrightAfter (4 times treatment)