Page 1: ADVA FSP 3000 Technical Overview.pdf

Robust design and superior

coverage, backed by experts

OpticalSpectrumServices

ADVA FSP 3000

Technical overview

Page 2: ADVA FSP 3000 Technical Overview.pdf

The information provided within this pack represents no commitment and is not intended to be an offer in whole or part. Openreach makes every effort to ensure the information is accurate at the time of compilation, however, Openreach does not represent that it is complete and Communications Providers should check with Openreach for the latest available information.

It should be noted that proposals for the products outlined in this slide-pack represent Openreach’s current view at the time of publication. These proposals may change through further development and feedback. All timescales are target estimates only. Any developments carried out by CPs based on this information are therefore entirely at the CP’s own risk.

Some statements involve risks and uncertainties. Actual outcomes may differ materially from those expressed or implied by these forward-looking statements, which may include, without limitation, changes in market conditions; supplier arrangements; future regulatory actions and conditions.

The information contained in these slides is to be used for information purposes only and must not be modified without express permission in writing from British Telecommunications plc.

This pack is updated intermittently. The Openreach portal should always be referred to for the latest product and contractual information.

British Telecommunications plc Registered office: 81 Newgate Street London EC1A 7AJ Registered in England no. 1800000

© British Telecommunications plc 2010

About this pack

Page 3: ADVA FSP 3000 Technical Overview.pdf

OSA overview ADVA FSP 3000

Enhanced optical terminating equipment from ADVA

Optical Networking

Attractive entry level prices

Commercial and technical flexibility (via Slimline & 7U

chassis)

Route distance range – up to 100Km available

Efficient use of space and power

Wide range of flexible options for design

Additional resilience capability for RO1 circuits

Improved management of technical data for customers

Approved to Impact Level 2

System latency Initial view available

at pre design stage

with actuals upon

installation

Lead times

targeted at 35

working days

for forecast orders

Page 4: ADVA FSP 3000 Technical Overview.pdf

A fully featured, high capacity chassis, with slimline

(1U) and 7U options which provides the flexibility to

meet an extensive range of needs at a great price.

Slimline 1U chassis

1U has a double card slot capability. This can run either

without filters (max 1 wavelength) or with an additional 1U

passive filter shelf (max 4 wavelengths)

Standard and RO2 bearer options

Ideal to deliver higher volumes of 1Gig services

Standard 7U chassis

Chassis capacity - 12 channels, less if double-width

transponders or RO1 used. Bearer will have capacity for 32

optical channels, in most cases this will require 3 chassis, but

could be more if double-width cards are used

Standard, RO1* and RO2 bearer options

Future FSP 3000 developments – rings & chains

* RO1 uses a protection module known as the VSM card. This will

protect against fibre breaks only and will use one wavelength on

the bearer, leaving 31 for customer use.

OSA overview ADVA FSP 3000

Page 5: ADVA FSP 3000 Technical Overview.pdf

ADVA FSP 3000 Slim line 1U chassis

Single (1 slot) – with RO2 option

1U high chassis for a single wavelength (all card types)

Compact service option

Can be upgraded by adding expansion

filters and chassis.

Standard (2 slots) – with RO2 option

Enables the build of a mini Optical system to cater for

up to four wavelengths

Can be grown by adding extra modules.

1U chassis offers a choice of

configurations and a low entry price

product to meet light initial requirements.

Uses less space in the exchange and

provides an ideal solution where there is

limited space to terminate an Optical

service.

The single (1 slot) option allows you to

start small with lower risk.

Choosing an additional filter pack

(standard option) will enable you to grow

capacity easily (up to 4 wavelengths) and

at your own pace. Service Card Slot 2 (Not Used)

Service Card Slot 1

(Contains LES10000 service card)

Service Card Slot 2 (Not Used)

Service Card Slot 1

(Contains LES10000 service card)

Service Card Slot 2 (Not Used)

Service Card Slot 1

(Contains LES10000 service card) 1U high chassis

(two slots)

Passive shelf

required for

filters

Page 6: ADVA FSP 3000 Technical Overview.pdf

ADVA FSP 3000 7U high chassis option

A fully featured, high capacity chassis

which provides the flexibility to meet an

extensive range of needs at a great

price.

16 slots available for all card types

including transponders, filters, protection

cards and optical supervisory cards

12 channel chassis capacity (less if

double-width transponders or RO1 used)

32 optical channel** bearer capacity (in

most cases this will require 3 chassis,

more if double-width cards are used)

Resilient options RO1 and RO2.

Page 7: ADVA FSP 3000 Technical Overview.pdf

FSP 3000 distance support

The FSP 3000 provides increased distance support by means of end point optical amplifiers. Distances of up to 103km route can be supported.

It has been agreed that planning rules will be introduced so that 4Gig cards can be deployed with a shorter reach.

Service offering

10Gb

Access Card

Dual Port D09533

(km)

4Gb

Access Cards

4 Port D09529

4 Port D09530

(km)

10Gb

Core Card

Dual Port D09531

(km)

2.5Gb & 10Gb

Enterprise &

Core Cards

5 Port D09534

10 Port D09532

Single Port D09526

Single Port D09527

Dual Port D09528

(km)

OSA RO1 with booster +

pre-amp

50 64 71 100

OSA standard & RO2 with

booster + pre-amp

66 72 76 103

Page 8: ADVA FSP 3000 Technical Overview.pdf

About Impact Level 2 (IL2)

Assurance that the FSP 3000 systems/products meet the security level 2.2.4 for Confidentiality, Integrity and Availability respectively.

Allows the ADVA FSP 3000 to be used to tender for Her Majesty's Government (HMG) network contracts at the ‘PROTECT’ level.

Benefits to you:

Enables/supports bids in key sectors

Peace of mind at no extra cost

Covers new and existing circuits

Can be built upon by you to offer even greater security

Page 9: ADVA FSP 3000 Technical Overview.pdf

Interface card details and

design parameters

Page 10: ADVA FSP 3000 Technical Overview.pdf

Card options

D-code Bandwidth Protocols

Single port cards D09527 2.5Gb STM16, GE, STM-4, STM-1, OTU1

D09526 10Gb STM64, 10GbE WAN, 10GbE LAN and 10G FC, OTU2

Multi-port cards

4 port (Data) D09529 4Gb GEx4, 1Gb FCx4, 2Gb FCx2, 4Gb FC, 2G Coupling Link

4 port (TDM) D09530 4Gb STM1x4, STM4x4, 1GEx4

10 port D09532 10Gb GEx9, 1Gb FCx10, 2Gb FCx5, 4Gb FCx2, STM1x10, STM4x10, STM16x3

2 port D09528 2.5Gb STM16, 1GFCx2 GbEx2, OTU1

2 port D09531 10Gb STM64, 10GbE WAN, 10GbE LAN, 8Gb FC, OTU2 (10GFC not supported)

2 port

D09533 10Gb STM64, 10GbE WAN, 10GbE LAN, 4Gb FC, 8GFC, OTU2 (10GFC not supported) *Low latency card*

5 port D09534 Max 10Gb 1Gb/2Gb/4Gb/8Gb/10Gb FC, GE, 10GE (LAN PHY only), ISC-3

ADVA FSP 3000 – card options

Page 11: ADVA FSP 3000 Technical Overview.pdf

OSA guidelines – FSP 3000 Protocol support

Service Supported Interfaces

CORE CARDS ENTERPRISE ACCESS CARDS

WC

C-P

CT

N-1

0G

(D09

52

6)

2W

CC

-PC

N-1

0G

(D09

53

1)

10

TC

C-P

CT

N-4

GU

S+

10

G

(D09

53

2)

2T

WC

C-P

CN

-2G

7U

(D09

52

8)

WC

C-P

C1N

-2G

7U

(Do9

52

7)

5T

CE

-PC

TN

-10

GU

+1

0G

(D09

53

4)

4T

CA

-PC

N-4

GU

+4

G

(D09

52

9)

4T

CA

-PC

N-4

GU

S+

4G

(D09

53

0)

2W

CA

-PC

N-1

0G

(D09

53

3)

TDM

STM-1 X X X

STM-4 X X X

STM-16 X X X

STM-64 X X X

Ethernet

Gig E X X X X X

10GE LAN PHY X X X X

10GE WAN PHY X X X

SAN Services

1G Fibre Channel / FICON X X X X

2G Fibre Channel / FICON Express X X X X

4G Fibre Channel / FICON X X X X

8G Fibre Channel / FICON X X X

10G Fibre Channel X X X

OTN

OTU1 X X

OTU2 X X X

Page 12: ADVA FSP 3000 Technical Overview.pdf

OSA guidelines – FSP 3000 Port information

Traffic cards Network Port Client Ports

Max

rat

e p

er

po

rt

Inte

rfac

e ty

pe

Qu

anti

ty

Max

rat

e p

er

po

rt

Inte

rfac

e t

ype

Qu

anti

ty

Core Cards

WCC-PCTN-10G (D09526) 11G Tuneable 1 11G XFP 1

2WCC-PCN-10G (D09531) 11G XFP 2 11G XFP 2

10TCC-PCTN-4GUS+10G (D09532) 10.7G Tuneable 1 4G SFP 10

2TWCC-PCN-2G7U (D09528) 2.6G SFP 2 2.6G SFP 2

WCC-PC1N-2G7U (D09527) 2.6G SFP 1 2.6G SFP 1

Enterprise Cards

5TCE-PCTN-10GU+10G (D09534) 11.3G Tuneable 1 10.5G

SFP,

SFP+ 5

Access Cards

4TCA-PCN-4GU+4G (D09529) 4.25G SFP 2 4.25G SFP 4

4TCA-PCN-4GUS+4G (D09530) 4.25G SFP 2 1.25G SFP 4

2WCA-PCN-10G (D09533) 10.7G XFP 2 10.7G XFP 2

Page 13: ADVA FSP 3000 Technical Overview.pdf

OSA guidelines – FSP 3000 Interface support

1310nm Single mode fibre client interfaces

Available for all protocols

Default unless you state otherwise

850nm Multi mode fibre client interfaces

Available for protocols less than 4G

Not used for SDH and OTN interfaces

Page 14: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution Protocol support

OTN

OTU-1

OTU-2

SDH

STM-1

STM-4

STM-16

STM-64

Ethernet

GbE

10GbE LAN PHY

10GbE WAN PHY

SAN / HPC

1G FC/FICON

2G FC/FICON 4G FC/FICON 8G FC/FICON 10G FC/FICON 2G/ ISC-3 NEW Coupling Link

OSA UPDATES › New protocol support

› Removal of low volume, low bandwidth protocols

› Greater certification

Sysplex Timer ETR & CLO

G-link

Fast Ethernet

Coupling Link 1G

Page 15: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution Resilience options

VSM Protection

Unprotected

Single OSA Bearer Diversely routed fibre paths. Traffic automatically switched to secondary fibre path in the event a problem occurring on the primary route

OSA Resilience Option 1 (RO1) SITE-A

SITE-A

SITE-B

SITE-B

Client Protection

SITE-B

Tr Client Tr Client

Two OSA Bearers Diversely routed fibre paths No automatically protection switching (must be done via customer client equipment) Customers are free to use the bearer as they wish

Resilience Option 2 (RO2) OSA Standard & OSA Single support

Single OSA Bearer Single fibre path No circuit or path protection OSA single has no filters

OSA Standard / OSA Single

Tr Client Tr Client

Tr Client

SITE-A

Tr Client

Client

VS

M

Tr Client

VS

M

Tr

Page 16: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution Architecture options

Pre-amplifier

Booster-amplifier

SITE-A SITE-B

Add/Drop Traffic

Add/Drop Traffic

SITE-A SITE-B

Add/Drop Traffic

Add/Drop Traffic

SITE-A SITE-B

Add/Drop Traffic

Add/Drop Traffic

Page 17: ADVA FSP 3000 Technical Overview.pdf

FSP 3000 overview Chassis with modules

7HU chassis example

PSU (redundant)

SCU

NCU-II

OSCM + OSFM

EDFA + DCM

Filters

Transponders

Page 18: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution Chassis options

1U Chassis

– Passive − 4 slots (for filters only)

7U

1U

7U Chassis 20 slots

AC or DC PSU – Duplicated

452mmx311mmx270mm (WxHxD)

1U Chassis options AC or DC – Duplicated PSU

• 2 slots

• AC versions needs rear access

1U

OSA OPTIONS

7U Chassis (AC or DC) Supports:

• Standard • R01 • R02

1U Chassis (AC or DC) Supports:

• Single • Standard • RO2

1U Chassis (Passive) Supports

• Standard • RO2

For filter housing only

OSA UPDATES › 1U chassis options

Page 19: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution Management

Management Router

Management Router

Up to 20 shelves can be cascaded in one network element

For OSA 3 or 4 max likely

Up to 4 shelves can be cascaded in one OSA network element

Excluding a passive shelf

Network element Control Unit = NCU

Shelf Controller Unit = SCU

NOTE: The SCU kit comes supplied with 90cm and 500cm MM Fibres. If your installation requires more please highlight

Multi mode fibre Cat-5 cable

Page 20: ADVA FSP 3000 Technical Overview.pdf

Key features

CORE modules

WCC / TCC

Application-specific

Certified for dedicated enterprise applications

Pluggable network interfaces

Highly reliable, serial design

FEC, ECC, GFP

Full set of SDH/Sonet and OTH features (PM, (G)-AIS/RDI, TCM)

Single board path protection for network interfaces

Cost optimized

Transparent

Performance optimized

Compliance focused (SDH/Sonet, OTH, RMON features)

ACCESS modules

WCA / TCA

ENTERPRISE modules

WCE / TCE

Supports special storage protocols

Certified and tested within special storage environment

OSA FSP 3000 solution Channel modules - overview

Description

Page 21: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution WCC-PCTN-10G-V(LN) ‘Transponder’ (D09526)

Network ports

– Discrete I/F with tuneable laser

− Tuneable DWDM (81ch C-Band, 41ch L-Band)

− Supports all 32 OSA frequencies

– LN version available

− long reach, noise optimized network interface

Client ports

– 1x XFP 1310nm

− 850nm and 1550nm available but not supported for OSA

– OSA Applications

− STM-64, 10 GbE LAN PHY, 10 GbE WAN PHY, 10G FC & OTU2

Forward error correction support (FEC)

– GFEC & EFEC-2 support

Inband management support (embedded control channel ECC)

– GCCx, DCCr/SDCC and proprietary ECC for wrapped 10GbE

Performance monitoring (PM)

– Full set of digital PM and Fault Monitoring options for Physical layer, PCS, 10 GbE layer, SDH/SONET layers, OTN layer, FEC layer, TCM monitoring

– SW loop backs

Dimensions & power consumption

– 1 slot wide

– <30W

WCC-PCTN-10G

TUN

XFP

PCS: physical coding sublayer

Page 22: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution 2WCC-PCN-10G ‘Dual Transponder’ (D09531)

Network ports

– 2x XFP (XFP/11G/Dxxxx.xxV/SM/LC#Dxx)

− Supports all 32 OSA frequencies

Client ports

– 2x XFP 1310nm

− 850nm and 1550nm available but not supported for OSA

– OSA Applications

− STM-64 & OTU2

− 10 GbE LAN PHY, 10 GbE WAN PHY & 8G FC

Forward error correction support (FEC)

– GFEC & EFEC-2 support

Inband management support (embedded control channel ECC)

– DCCr (SDCC) and GCCx support on network port

Performance monitoring (PM)

– Full set of digital PM and Fault Monitoring options for Physical layer, PCS, 10 GbE layer, SDH/SONET layers, OTN layer, FEC layer, TCM monitoring

– SW loop backs

Dimensions & power consumption

– 1 slot wide

– <45W

2WCC-PCN-10G

XFP

XFP

XFP

XFP

PCS: physical coding sublayer

Clie

nt-

1 i.

e.

10

Gb

E

Clie

nt-

2 i.

e.

10

Gb

E

1

2

Page 23: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution 10TCC-PCTN-4GUS+10G-V(LN) ‘Muxponder’ (D09532)

Network ports

– Discrete I/F with tuneable laser

− Tuneable DWDM (81ch C-Band, 41ch L-Band)

− Supports all 32 OSA frequencies

– LN version available: long reach, noise optimized network

interface

Client ports

– 10x SFP

− 850nm and 1310nm 2.5G & 4G variants

− 1550nm available but not supported for OSA

– OSA Applications

− STM-1, STM-4 & STM-16

− GbE, 1G FC, 2G FC & 4G FC

Forward error correction support (FEC)

– GFEC & EFEC-2 support

Inband management support (embedded control channel ECC)

– GCCx, DCCr/SDCC & DCCm/LDCC

Performance monitoring (PM)

– Full set of digital PM and Fault Monitoring options for

Physical layer, GbE and GFP layer, SDH/SONET/OTN

layers, FEC layer, TCM monitoring

– SW loop backs

Dimensions & power consumption

– 2 slot wide

– <67W

10TCC-PCTN-4GUS+10G

SFP

TUN

SFP

SFP

SFP

SFP

SFP

SFP

SFP

SFP

SFP

VC4 per service

Max services

STM-1 2 10

STM-4 5 10

STM-16 18 3

GbE 7 9

1G FC 6 10

2G FC 12 5

4G FC 24 2

Any mix of the above if the total amount of 64xVC4 is not exceeded

Page 24: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution 2TWCC-PCN-2G7U ‘Dual Transponder/Muxponder’ (D09528)

Network ports

– 2x SFP (SFP/2G5U/xxxxU/SM/LC#Dxx)

− Supports all 32 OSA frequencies

Client ports

– 2x SFP 1310nm

− 850nm and 1310nm

– OSA Applications

− STM-16 & OTU-1 in transponder mode

− GbE, 1G FC & 2G FC in Multiplexer mode

Forward error correction support (FEC)

– GFEC

Inband management support (embedded control channel ECC)

– GCC1/GCC2 on client port, DCCr/SDCC, GCC0

Performance monitoring (PM)

– Full set of digital PM and Fault Monitoring options for Physical layer, GbE and GFP layer, SDH/SONET/OTN layers, FEC layer, TCM monitoring

– SW loops back

Dimensions & power consumption

– 1 slot wide

– <30W

2TWCC-PCN-2G7U

SFP

SFP

SF

P

Clie

nt-

1 i.

e.

Gb

E

Clie

nt-

2 i.

e.

Gb

E

1

2TWCC-PCN-2G7U

SFP

SFP

SFP

SFP

C

lien

t-1

i.e.

O

TU-1

Clie

nt-

2 i.

e.

OTU

-1

1

2

Page 25: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution WCC-PC1N-2G7U ‘Transponder’ (D09527)

Network ports

– 2x SFP (SFP/2G5U/xxxxU/SM/LC#Dxx)

− Supports all 32 OSA frequencies

Client ports

– 2x SFP

− 850nm and 1310nm

– OSA Applications

− STM-1, STM-4 & STM-16

− GbE & OTU-1

Forward error correction support (FEC)

– GFEC

Inband management support (embedded control channel ECC)

– GCCx and DCCr (SDCC)

Performance monitoring (PM)

– Full set of digital PM and Fault Monitoring options for Physical layer, GbE layer, SDH/SONET/OTN layers, PCS and FEC layers, TCM monitoring

– SW loop backs

Dimensions & power consumption

– 1 slot wide

– <20W

PCS: physical coding sublayer

WCC-PC1N-2G7U

SFP

SF

P

Page 26: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution 5TCE-PCTN-10GU+10G ‘Muxponder/SAN card’ (D09534)

Network ports

– Discrete I/F with tuneable laser

− Tuneable DWDM (81ch C-Band, 41ch L-Band)

− Supports all 32 OSA frequencies

– LN version available: long reach, noise optimized network interface

Client ports

– 5x SFP or up to 2x SFP+

− 850nm and 1310nm 2.5G & 4G SFP variants

− 1310nm SFP+ 10G & 8G variants

– OSA Applications

− 1G FC, 2G FC, 4G FC, 8G FC & 10G FC ISC-3

− GbE & 10 GbE LAN PHY (10GbE WAN PHY not supported)

Forward error correction support (FEC)

– GFEC

Inband management support (embedded control channel ECC)

– GCC0 (1312 kbit/s)

Performance monitoring (PM)

– Physical, PCS, FEC, Ethernet Layer

– SW loop backs

– Latency measurement

Dimensions & power consumption

– 1 slot wide

– <42W (Max 13 cards per 7U shelf)

5TCE-PCTN-10GU+10G

SFP

TUN

SFP

SFP

SFP

SFP

› Recommended for:

› SAN - Greater certification

› HPC - Greater certification

Page 27: ADVA FSP 3000 Technical Overview.pdf

5TCE – Features and benefits

Feature Benefit

Tuneable network port Easy sparing concept

Wavelength spectrum: 80ch. (C) + 40ch. (L)

Highest transport capacity

G-FEC on network port Extended distances up to 1200km

Client applications: 1G, 2G, 4G, 8G, 10G FC GbE, 10GE 5G / 10G IB, ISC-3

One card fits all - investment protection

Latency optimized muxing Perfect fit for latency sensitive apps

Constant Bit Rate (CBR) mux mode 100% transparent transport – no interop issues

Dynamic end-to-end latency measurement Easy provisioning of buffer credits

Encryption Highest security transmission

Page 28: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution 4TCA-PCN-4GU+4G ‘Muxponder / ADM’ (D09529)

Network ports

– 2x SFP 4G (SFP/4GU/xxxxV/SM/LC#Dxx)

− Supports all 32 OSA frequencies

Client ports

– 4x SFP

− 850nm and 1310nm 2.5G & 4G SFP variants

– OSA Applications

− GbE, 1G FC, 2G FC & 4G FC

– 4 x GbE, 4 x 1G FC, 2 x 2G FC, 1 x 4G FC or mix of services (ADM

mode)

– 4 x GbE, 4 x 1G FC, 4 x 2G FC, 2 x 4G FC or mix of services (Dual mux

mode)

Forward error correction support (FEC)

– None

Inband management support (embedded control channel ECC)

– Proprietary

Performance monitoring (PM)

– Physical Layer, CV, CRC, SE, SES

– SW loop backs

Dimensions & power consumption

– 1 slot wide

– <25W

CV: coding violation CRC: cyclic redundancy check SE: synch header error SES: severely errored seconds

4TCA-PCN-4GU+4G

SFP

SFP

SFP

SFP

SFP

SFP

Page 29: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution 4TCA-PCN-4GUS+4G ‘Muxponder / ADM’ (D09530)

Network ports

– 2x SFP 4G (SFP/4GU/xxxxV/SM/LC#Dxx)

− Supports all 32 OSA frequencies

Client ports

– 4x SFP

− 850nm and 1310nm 2.5G

– OSA Applications

− GbE, STM-1 & STM-2

– 4 x GbE, 4 x STM-4, 4 x STM-1 or mix of services

Forward error correction support (FEC)

– None

Inband management support (embedded control channel ECC)

– Proprietary

Performance monitoring (PM)

– Physical Layer, CV, CRC, SE, SES

– SW loop backs

Dimensions & power consumption

– 1 slot wide

– <25W

CV: coding violation CRC: cyclic redundancy check SE: synch header error SES: severely errored seconds

4TCA-PCN-4GUS+4G

SFP

SFP

SFP

SFP

SFP

SFP

Page 30: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution 2WCA-PCN-10G ‘Dual Transponder’ (D09533)

Network ports

– 2x XFP (XFP/11G/Dxxxx.xxV/SM/LC#Dxx)

− Supports all 32 OSA frequencies

− 8G XFP used for 8G FC

Client ports

– 2x XFP 1310nm

− 850nm and 1550nm available but not supported for OSA

− 8G XFP used for 8G FC

– OSA Applications (Recommended for ‘low latency’ solutions)

− 4G FC, 8G FC, 10G FC

− 10 GbE LAN, 10 GbE WAN, STM-64 & OTU-2

Forward error correction support (FEC)

– None

Inband management support (embedded control channel ECC)

– None

Performance monitoring (PM)

– Analogue PM and Fault Monitoring for Physical layer

– SW loop backs

Dimensions & power consumption

– 1 slot wide

– <20W

Clie

nt-

1 i.

e.

10

Gb

E

Clie

nt-

2 i.

e.

10

Gb

E

1

2

2WCA-PCN-10G

XFP

XFP

XFP

XFP

Page 31: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution OSA Filter options-1

8G

SM

Line

4CSM

SINGLE WAVELENGTH No filters

OSA Single support

OSA RO2 support

4CSM 4CSM

4CSM 4CSM

4CSM 4CSM

4CSM 4CSM

Line Line

FOUR WAVELENGTHS 1 filter OSA Standard support OSA RO1 support OSA RO2 support

32 WAVELENGTHS 2 to 9 filters OSA Standard support OSA R01 support OSA RO2 support

OSA Single OSA Standard OSA Standard (7U Chassis)

Page 32: ADVA FSP 3000 Technical Overview.pdf

OSA FSP 3000 solution OSA upgrades

Installation Modify required

1U Single Upgrade to 1U Standard

1U Single Upgrade 7U Standard

1U Standard Upgrade to 7U Standard

1U Single Upgrade to 1U Single RO2

1U Standard Upgrade to 1U RO2

1U Standard Upgrade to 7U RO1

1U Standard Upgrade to 7U RO2

1U RO2 Upgrade to 7U RO2

7U Standard 7U RO2

7U Standard Upgrade to 7U RO1

Provide greater capacity

Additional shelves and/or

Filters

Add protection

Additional shelves, filters, protection units maybe needed

Page 33: ADVA FSP 3000 Technical Overview.pdf