adr155c to p5.7.0 ang_ed5
DESCRIPTION
Sagem adr155TRANSCRIPT
ADR155cADR155c
ADR155cSoftware Upgrade Procedure
to Release P5.7.0
document.docIssue 2 - 29/08/2011
CONTENTSCONTENTS
1 Introduction..........................................................................................................................3
2 Before Installing..................................................................................................................5
3 Upgrade Procedure............................................................................................................6
3.1 Release P5.3.3 to P5.7.0....................................................................................................6
3.1.1 ADR155c software installation.............................................................................6
3.2 Release P5.4.1 to P5.7.0..................................................................................................10
3.2.1 ADR155c software installation...........................................................................10
3.3 Release P5.4.5 to P5.7.0..................................................................................................14
3.3.1 ADR155c software installation...........................................................................14
3.4 Release P5.4.6 to P5.7.0..................................................................................................18
3.4.1 ADR155c software installation...........................................................................18
3.5 Release P5.5.0 to P5.7.0..................................................................................................22
3.5.1 ADR155c software installation...........................................................................22
3.6 Release P5.6.0 to P5.7.0..................................................................................................26
3.6.1 ADR155c software installation...........................................................................26
3.7 Release P5.6.1 to P5.7.0..................................................................................................29
3.7.1 ADR155c software installation...........................................................................29
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
2 / 22 document.docIssue 2 - 29/08/2011
1 IntroductionThis note defines the procedure for upgrading the ADR155c software to the Release P5.7.0.
Warning : The ADR155c equipment at a release lower than P5.3.3 cannot be upgrading directly to the release P5.7.0. It must be upgraded to the release P5.3.3 before realizing this procedure.For upgrading the ADR155c to the relesase P5.3.3, see the document "ADR155c Software Upgrade Procedure to Release P5.3.3".
The tables below provide a list of the software changes per release:
Software Old Code (Release P5.3.3)New Code
(Release P5.7.0)FPGA Pack 252 689 520AB-ue 253 349 071AA-we
GFP150 board Application (ADRGFP150)
251 863 036AJ-nc 251 863 036AK-of
Motherboard Application 252 689 517AC-mu 3 000 297 311-sa
Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesn’t cause a traffic interruption during the reboot of the equipment.
Note: Beginning from P5.4.6 version, 4E/FE board can support jumbo frame function. In P5.7.0 version, to use this feature, it is necessary to do “No service” then “Service” the 4E/FE board after the upgrade. The operation of “No service” then “Service” causes a traffic interruption of 4E/FE board. (60 seconds max.).
SoftwareOld Code
(Release P5.4.1)New Code
(Release P5.7.0)FPGA Pack 252 860 667AA-vm 253 349 071AA-we
GFP150 board Application (ADRGFP150)
251 863 036AJ-nc 251 863 036AK-of
Motherboard Application 252 860 654AA-ni 3 000 297 311-sa
Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesn’t cause a traffic interruption during the reboot of the equipment.
Note: Beginning from P5.4.6 version, 4E/FE board can support jumbo frame function. In P5.7.0 version, to use this feature, it is necessary to do “No service” then “Service” the 4E/FE board after the upgrade. The operation of “No service” then “Service” causes a traffic interruption of 4E/FE board. (60 seconds max.).
SoftwareOld Code
(Release P5.4.5)New Code
(Release P5.7.0)FPGA Pack 252 860 667AA-vm 253 349 071AA-we
GFP150 board Application (ADRGFP150)
251 863 036AK-oe 251 863 036AK-of
Motherboard Application 3 000 297 311-og 3 000 297 311-sa
Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesn’t cause a traffic interruption during the reboot of the equipment.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
3 / 22 document.docIssue 2 - 29/08/2011
Note: Beginning from P5.4.6 version, 4E/FE board can support jumbo frame function. In P5.7.0 version, to use this feature, it is necessary to do “No service” then “Service” the 4E/FE board after the upgrade. The operation of “No service” then “Service” causes a traffic interruption of 4E/FE board. (60 seconds max.).
SoftwareOld Code
(Release P5.4.6)New Code
(Release P5.7.0)FPGA Pack 252 860 667AA-vm 253 349 071AA-we
GFP150 board Application (ADRGFP150)
251 863 036AK-oe 251 863 036AK-of
Motherboard Application 3 000 297 311-ol 3 000 297 311-sa
Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesn’t cause a traffic interruption during the reboot of the equipment.
SoftwareOld Code
(Release P5.5.0)New Code
(Release P5.7.0)FPGA Pack 253 209 235AA-wc 253 349 071AA-we
GFP150 board Application (ADRGFP150)
251 863 036AK-oe 251 863 036AK-of
Motherboard Application 3 000 297 311-pd 3 000 297 311-sa
Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesn’t cause a traffic interruption during the reboot of the equipment.
Note: In P5.7.0 version, it is necessary to do “No service” then “Service” the 4E/FE+1GE board after the upgrade. The operation of “No service” then “Service” causes a traffic interruption of 4E/FE+1GE board. (60 seconds max.).
SoftwareOld Code
(Release P5.6.0)New Code
(Release P5.7.0)GFP150 board Application
(ADRGFP150)251 863 036AK-oe 251 863 036AK-of
Motherboard Application 3 000 297 311-qe 3 000 297 311-sa
Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesn’t cause a traffic interruption during the reboot of the equipment.
SoftwareOld Code
(Release P5.6.1)New Code
(Release P5.7.0)Motherboard Application 3 000 297 311-rb 3 000 297 311-sa
Upgrading the Motherboard software application doesn’t cause a traffic interruption during the reboot of the equipment.
Note: In P5.7.0 version, it is necessary to do “No service” then “Service” the GFP150 board after the upgrade. The operation of “No service” then “Service” causes a traffic interruption of GFP150 board. (60 seconds max.).
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
4 / 22 document.docIssue 2 - 29/08/2011
2 Before Installing
Check that all ADR155c equipment to be upgraded are accessible and aren't in written session.
Check that all ADR155c equipment to be upgraded are without alarms. In the opposite case, process them before realizing this procedure.
Check that boards are inserted in all configured slots.
Check that the Tftpd32 application is started on the IONOS NMS TFTP server.
If the MSP 1+1 protection is used, check that the traffic is on the working path then deactivate the MSP 1+1 protection for each equipment to be upgraded of the STM1 section.
Note the TFTP server address.
The following files are available:
- Fpga56we.gz- Gfp150of.gz- Adr570sa.gz
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
5 / 22 document.docIssue 2 - 29/08/2011
3 Upgrade Procedure
3.1 Release P5.3.3 to P5.7.0
3.1.1 ADR155c software installation
ADR155c upgrade:
Software (*) Old Code New Code (*)
Motherboard Boot 252 165 976AC-ec 252 165 976AC-ec
Motherboard Application 252 689 517AC-mu 3 000 297 311-sa
FPGA Pack 252 689 520AB-ue 253 349 071AA-weGFP150 board Application
(ADRGFP150)251 863 036AJ-nc 251 863 036AK-of
(*): Modified software appears in Bold type
No STM1-DUAL-4G, STM1-DUAL-5G, STM1-SFP-4G, STM1-SFP-5G, 4E/FE+1GE and GFP150 (253 243 224-B or upper) board must be inserted into the shelf before starting the upgrade procedure.
Upgrade procedure with HTTP and a TFTP server for FPGA Pack as well as GFP150 (ADRGFP150) and Motherboard software Application:
- Copy the files Fpga56we.gz, Gfp150of.gz and Adr570sa.gz into the reference (root) directory of the TFTP server. (« IONOS NMS installation directory »\tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server address under « TFTP Server ».
Fill the « File » description and select the « Type of Downloaded Informations ».
- Download FPGA Pack : « File » Fpga56we.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 45 seconds per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download GFP150 (ADRGFP150) Application code : « File » Gfp150of.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 1 minute per intermediate equipment).
Use the Switching menu to check the version of the downloaded codes.(Select the menu then « Switching »)
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
6 / 22 document.docIssue 2 - 29/08/2011
Switch (Switch command) the GFP150 (ADRGFP150) Code.Validate the warning message.The traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code. This causes a hot reset.Validate the warning message.The traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.(Menus : « Up and Download\Download »)
In the Download menu, fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download FPGA Pack : « File » Fpga56we.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 45 seconds per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then check the downloaded code.The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function, it is necessary to do “No Service” then “Service” every board.(Select the 4E/FE board then the menu : « Service »)The traffic of 4E/FE board(s) is interrupted while this command is executed. (60 seconds max.).
Upgrade procedure with IONOS NMS and a TFTP server for FPGA Pack as well as GFP150 (ADRGFP150) and Motherboard software Application:
Note: With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be beforehand downloaded by HTTP in the equipment.With IONOS NMS P4.4 or higher, the FPGA Pack (File: Fpga56we.gz) can be downloaded by IONOS NMS.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
7 / 22 document.docIssue 2 - 29/08/2011
- Copy the files Fpga56we.gz (with IONOS NMS P4.4 or higher), Gfp150of.gz and Adr570sa.gz into the directory on the hard disk of the PC. (For example: C:\ADR155c).
- Display the Software Management window.(In the menu bar of the Manager, select the menus: « Tools \ Software Management »).
- Choose the « Update » mode to download the new software.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select select the soft type: ADRGFP board and the switch type: Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed.It will be restored after the switching of the Motherboard Application code.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Switch » mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Select the soft type: Mother board.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
8 / 22 document.docIssue 2 - 29/08/2011
- Click the « Show list » button to create the equipment list with the software inventory then on the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the GFP150 (ADRGFP150) board accesses is restored.The traffic of other accesses isn’t interrupted while this command is executed.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Update » mode to download the FPGA (With IONOS NMS P4.4 or higher) and Motherboard Application code (Second download).
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Click the « Close » button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs with a red cross.
- With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be beforehand downloaded by HTTP in the equipment (Second download).
- If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function, it is necessary to do “No Service” then “Service” every board.(With HTTP, select the 4E/FE board then the menu : « Service »)The traffic of 4E/FE board(s) is interrupted while this command is executed. (60 seconds max.).
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
9 / 22 document.docIssue 2 - 29/08/2011
3.2 Release P5.4.1 to P5.7.0
3.2.1 ADR155c software installation
ADR155c upgrade:
Software (*) Old Code New Code (*)
Motherboard Boot 252 165 976AC-ec 252 165 976AC-ec
Motherboard Application 252 860 654AA-ni 3 000 297 311-sa
FPGA Pack 252 860 667AA-vm 253 349 071AA-weGFP150 board Application
(ADRGFP150)251 863 036AJ-nc 251 863 036AK-of
(*): Modified software appears in Bold type
No STM1-DUAL-5G, STM1-SFP-5G, 4E/FE+1GE and GFP150 (253 243 224-B or upper) board must be inserted into the shelf before starting the upgrade procedure.
Upgrade procedure with HTTP and a TFTP server for FPGA Pack as well as GFP150 (ADRGFP150) and Motherboard software Application:
- Copy the files Fpga56we.gz, Gfp150of.gz and Adr570sa.gz into the reference (root) directory of the TFTP server. (« IONOS NMS installation directory »\tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server address under « TFTP Server ».
Fill the « File » description and select the « Type of Downloaded Informations ».
- Download FPGA Pack : « File » Fpga56we.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 45 seconds per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download GFP150 (ADRGFP150) Application code : « File » Gfp150of.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 1 minute per intermediate equipment).
Use the Switching menu to check the version of the downloaded codes.(Select the menu then « Switching »)
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
10 / 22 document.docIssue 2 - 29/08/2011
Switch (Switch command) the GFP150 (ADRGFP150) Code.Validate the warning message.The traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code. This causes a hot reset.Validate the warning message.The traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.(Menus : « Up and Download\Download »)
In the Download menu, fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download FPGA Pack : « File » Fpga56we.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 45 seconds per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then check the downloaded code.The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function, it is necessary to do “No Service” then “Service” every board.(Select the 4E/FE board then the menu : « Service »)The traffic of 4E/FE board(s) is interrupted while this command is executed. (60 seconds max.).
Upgrade procedure with IONOS NMS and a TFTP server for FPGA Pack as well as GFP150 (ADRGFP150) and Motherboard software Application:
Note: With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be beforehand downloaded by HTTP in the equipment.With IONOS NMS P4.4 or higher, the FPGA Pack (File: Fpga56we.gz) can be downloaded by IONOS NMS.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
11 / 22 document.docIssue 2 - 29/08/2011
- Copy the files Fpga56we.gz (with IONOS NMS P4.4 or higher), Gfp150of.gz and Adr570sa.gz into the directory on the hard disk of the PC. (For example: C:\ADR155c).
- Display the Software Management window.(In the menu bar of the Manager, select the menus: « Tools \ Software Management »).
- Choose the « Update » mode to download the new software.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select select the soft type: ADRGFP board and the switch type: Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed.It will be restored after the switching of the Motherboard Application code.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Switch » mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Select the soft type: Mother board.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
12 / 22 document.docIssue 2 - 29/08/2011
- Click the « Show list » button to create the equipment list with the software inventory then on the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the GFP150 (ADRGFP150) board accesses is restored.The traffic of other accesses isn’t interrupted while this command is executed.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Update » mode to download the FPGA (With IONOS NMS P4.4 or higher) and Motherboard Application code (Second download).
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select the soft type : Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Click the « Close » button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs with a red cross.
- With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be beforehand downloaded by HTTP in the equipment (Second download).
- If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function, it is necessary to do “No Service” then “Service” every board.(With HTTP, select the 4E/FE board then the menu : « Service »)The traffic of 4E/FE board(s) is interrupted while this command is executed. (60 seconds max.).
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
13 / 22 document.docIssue 2 - 29/08/2011
3.3 Release P5.4.5 to P5.7.0
3.3.1 ADR155c software installation
ADR155c upgrade:
Software (*) Old Code New Code (*)
Motherboard Boot 252 165 976AC-ec 252 165 976AC-ec
Motherboard Application 3 000 297 311-og 3 000 297 311-sa
FPGA Pack 252 860 667AA-vm 253 349 071AA-weGFP150 board Application
(ADRGFP150)251 863 036AK-oe 251 863 036AK-of
(*): Modified software appears in Bold type
No STM1-DUAL-5G, STM1-SFP-5G, 4E/FE+1GE and GFP150 (253 243 224-B or upper) board must be inserted into the shelf before starting the upgrade procedure.
Upgrade procedure with HTTP and a TFTP server for FPGA Pack as well as GFP150 (ADRGFP150) and Motherboard software Application:
- Copy the files Fpga56we.gz, Gfp150of.gz and Adr570sa.gz into the reference (root) directory of the TFTP server. (« IONOS NMS installation directory »\tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server address under « TFTP Server ».
Fill the « File » description and select the « Type of Downloaded Informations ».
- Download FPGA Pack : « File » Fpga56we.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 45 seconds per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download GFP150 (ADRGFP150) Application code : « File » Gfp150of.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 1 minute per intermediate equipment).
Use the Switching menu to check the version of the downloaded codes.(Select the menu then « Switching »)
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
14 / 22 document.docIssue 2 - 29/08/2011
Switch (Switch command) the GFP150 (ADRGFP150) Code.Validate the warning message.The traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code. This causes a hot reset.Validate the warning message.The traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.(Menus: « Up and Download\Download »)
In the Download menu, fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download FPGA Pack : « File » Fpga56we.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 45 seconds per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then check the downloaded code.The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function, it is necessary to do “No Service” then “Service” every board.(Select the 4E/FE board then the menu : « Service »)The traffic of 4E/FE board(s) is interrupted while this command is executed. (60 seconds max.).
Upgrade procedure with IONOS NMS and a TFTP server for FPGA Pack as well as GFP150 (ADRGFP150) and Motherboard software Application:
Note: With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be beforehand downloaded by HTTP in the equipment.With IONOS NMS P4.4 or higher, the FPGA Pack (File: Fpga56we.gz) can be downloaded by IONOS NMS.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
15 / 22 document.docIssue 2 - 29/08/2011
- Copy the files Fpga56we.gz (with IONOS NMS P4.4 or higher), Gfp150of.gz and Adr570sa.gz into the directory on the hard disk of the PC. (For example: C:\ADR155c).
- Display the Software Management window.(In the menu bar of the Manager, select the menus: « Tools \ Software Management »).
- Choose the « Update » mode to download the new software.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select select the soft type: ADRGFP board and the switch type: Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed.It will be restored after the switching of the Motherboard Application code.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Switch » mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Select the soft type: Mother board.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the GFP150 (ADRGFP150) board accesses is restored.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
16 / 22 document.docIssue 2 - 29/08/2011
The traffic of other accesses isn’t interrupted while this command is executed.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Update » mode to download the FPGA (With IONOS NMS P4.4 or higher) and Motherboard Application code (Second download).
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Click the « Close » button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs with a red cross.
- With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be beforehand downloaded by HTTP in the equipment (Second download).
- If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function, it is necessary to do “No Service” then “Service” every board.(With HTTP, select the 4E/FE board then the menu : « Service »)The traffic of 4E/FE board(s) is interrupted while this command is executed. (60 seconds max.).
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
17 / 22 document.docIssue 2 - 29/08/2011
3.4 Release P5.4.6 to P5.7.0
3.4.1 ADR155c software installation
ADR155c upgrade:
Software (*) Old Code New Code (*)
Motherboard Boot 252 165 976AC-ec 252 165 976AC-ec
Motherboard Application 3 000 297 311-ol 3 000 297 311-sa
FPGA Pack 252 860 667AA-vm 253 349 071AA-weGFP150 board Application
(ADRGFP150)251 863 036AK-oe 251 863 036AK-of
(*): Modified software appears in Bold type
No STM1-DUAL-5G, STM1-SFP-5G, 4E/FE+1GE and GFP150 (253 243 224-B or upper) board must be inserted into the shelf before starting the upgrade procedure.
Upgrade procedure with HTTP and a TFTP server for FPGA Pack as well as GFP150 (ADRGFP150) and Motherboard software Application:
- Copy the files Fpga56we.gz, Gfp150of.gz and Adr570sa.gz into the reference (root) directory of the TFTP server. (« IONOS NMS installation directory »\tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server address under « TFTP Server ».
Fill the « File » description and select the « Type of Downloaded Informations ».
- Download FPGA Pack : « File » Fpga56we.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 45 seconds per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download GFP150 (ADRGFP150) Application code : « File » Gfp150of.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 1 minute per intermediate equipment).
Use the Switching menu to check the version of the downloaded codes.(Select the menu then « Switching »)
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
18 / 22 document.docIssue 2 - 29/08/2011
Switch (Switch command) the GFP150 (ADRGFP150) Code.Validate the warning message.The traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code. This causes a hot reset.Validate the warning message.The traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.(Menus : « Up and Download\Download »)
In the Download menu, fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download FPGA Pack : « File » Fpga56we.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 45 seconds per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then check the downloaded code.The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
Upgrade procedure with IONOS NMS and a TFTP server for FPGA Pack as well as GFP150 (ADRGFP150) and Motherboard software Application:
Note: With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be beforehand downloaded by HTTP in the equipment.With IONOS NMS P4.4 or higher, the FPGA Pack (File: Fpga56we.gz) can be downloaded by IONOS NMS.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
19 / 22 document.docIssue 2 - 29/08/2011
- Copy the files Fpga56we.gz (with IONOS NMS P4.4 or higher), Gfp150of.gz and Adr570sa.gz into the directory on the hard disk of the PC. (For example : C:\ADR155c).
- Display the Software Management window.(In the menu bar of the Manager, select the menus : « Tools \ Software Management »).
- Choose the « Update » mode to download the new software.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type : FPGA.
- Select the file Fpga56we.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select the soft type : Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select select the soft type: ADRGFP board and the switch type: Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed.It will be restored after the switching of the Motherboard Application code.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Switch » mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Select the soft type: Mother board.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the GFP150 (ADRGFP150) board accesses is restored.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
20 / 22 document.docIssue 2 - 29/08/2011
The traffic of other accesses isn’t interrupted while this command is executed.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Update » mode to download the FPGA (With IONOS NMS P4.4 or higher) and Motherboard Application code (Second download).
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select the soft type : Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Click the « Close » button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs with a red cross.
- With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be beforehand downloaded by HTTP in the equipment (Second download).
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
21 / 22 document.docIssue 2 - 29/08/2011
3.5 Release P5.5.0 to P5.7.0
3.5.1 ADR155c software installation
ADR155c upgrade:
Software (*) Old Code New Code (*)
Motherboard Boot 252 165 976AC-ec 252 165 976AC-ec
Motherboard Application 3 000 297 311-pd 3 000 297 311-sa
FPGA Pack 252 209 235AA-wc 253 349 071AA-weGFP150 board Application
(ADRGFP150)251 863 036AK-oe 251 863 036AK-of
(*): Modified software appears in Bold type
No GFP150 (253 243 224-B or upper) board must be inserted into the shelf before starting the upgrade procedure.
Upgrade procedure with HTTP and a TFTP server for FPGA Pack as well as GFP150 (ADRGFP150) and Motherboard software Application:
- Copy the files Fpga56we.gz, Gfp150of.gz and Adr570sa.gz into the reference (root) directory of the TFTP server. (« IONOS NMS installation directory »\tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server address under « TFTP Server ».
Fill the « File » description and select the « Type of Downloaded Informations ».
- Download FPGA Pack : « File » Fpga56we.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 45 seconds per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download GFP150 (ADRGFP150) Application code : « File » Gfp150of.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 1 minute per intermediate equipment).
Use the Switching menu to check the version of the downloaded codes.(Select the menu then « Switching »)
Switch (Switch command) the GFP150 (ADRGFP150) Code.Validate the warning message.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
22 / 22 document.docIssue 2 - 29/08/2011
The traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code. This causes a hot reset.Validate the warning message.The traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.(Menus: « Up and Download\Download »)
In the Download menu, fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download FPGA Pack : « File » Fpga56we.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 45 seconds per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then check the downloaded code.The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
If 4E/FE-1GE board(s) is(are) configured in the equipment, it is necessary to do “No Service” then “Service” every board.(Select the 4E/FE-1GE board then the menu : « Service »)The traffic of 4E/FE-1GE board(s) is interrupted while this command is executed. (60 seconds max.).
Upgrade procedure with IONOS NMS and a TFTP server for FPGA Pack as well as GFP150 (ADRGFP150) and Motherboard software Application:
Note: With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be beforehand downloaded by HTTP in the equipment.With IONOS NMS P4.4 or higher, the FPGA Pack (File: Fpga56we.gz) can be downloaded by IONOS NMS.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
23 / 22 document.docIssue 2 - 29/08/2011
- Copy the files Fpga56we.gz (with IONOS NMS P4.4 or higher), Gfp150of.gz and Adr570sa.gz into the directory on the hard disk of the PC. (For example: C:\ADR155c).
- Display the Software Management window.(In the menu bar of the Manager, select the menus: « Tools \ Software Management »).
- Choose the « Update » mode to download the new software.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select select the soft type : ADRGFP board and the switch type : Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed.It will be restored after the switching of the Motherboard Application code.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Switch » mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Select the soft type: Mother board.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
24 / 22 document.docIssue 2 - 29/08/2011
- Click the « Show list » button to create the equipment list with the software inventory then on the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the GFP150 (ADRGFP150) board accesses is restored.The traffic of other accesses isn’t interrupted while this command is executed.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Update » mode to download the FPGA (With IONOS NMS P4.4 or higher) and Motherboard Application code (Second download).
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Click the « Close » button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs with a red cross.
- With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be beforehand downloaded by HTTP in the equipment (Second download).
- If 4E/FE-1GE board(s) is(are) configured in the equipment, it is necessary to do “No Service” then “Service” every board.(Select the 4E/FE-1GE board then the menu : « Service »)The traffic of 4E/FE-1GE board(s) is interrupted while this command is executed. (60 seconds max.).
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
25 / 22 document.docIssue 2 - 29/08/2011
3.6 Release P5.6.0 to P5.7.0
3.6.1 ADR155c software installation
ADR155c upgrade:
Software (*) Old Code New Code (*)
Motherboard Boot 252 165 976AC-ec 252 165 976AC-ec
Motherboard Application 3 000 297 311-qe 3 000 297 311-sa
FPGA Pack 252 209 235AA-we 253 349 071AA-weGFP150 board Application
(ADRGFP150)251 863 036AK-oe 251 863 036AK-of
(*): Modified software appears in Bold type
No GFP150 (253 243 224-C or upper) board must be inserted into the shelf before starting the upgrade procedure.
Upgrade procedure with HTTP and a TFTP server for GFP150 (ADRGFP150) and Motherboard software Application:
- Copy the files Gfp150of.gz and Adr570sa.gz into the reference (root) directory of the TFTP server. (« IONOS NMS installation directory »\tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server address under « TFTP Server ».
Fill the « File » description and select the « Type of Downloaded Informations ».
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download GFP150 (ADRGFP150) Application code : « File » Gfp150of.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 1 minute per intermediate equipment).
Use the Switching menu to check the version of the downloaded codes.(Select the menu then « Switching »)
Switch (Switch command) the GFP150 (ADRGFP150) Code.Validate the warning message.The traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code. This causes a hot reset.Validate the warning message.The traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
26 / 22 document.docIssue 2 - 29/08/2011
The traffic of other accesses isn’t interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.(Menus : « Up and Download\Download »)
In the Download menu, fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then check the downloaded code.The Motherboard codes (current) and (reserve) are the same reference.
If GFP150 board(s) is(are) configured in the equipment, it is necessary to do “No Service” then “Service” every board. (Select the GFP150 board then the menu : « Service »)The traffic of GFP150 board(s) is interrupted while this command is executed. (60 seconds max.).
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
Upgrade procedure with IONOS NMS and a TFTP server for GFP150 (ADRGFP150) and Motherboard software Application:
- Copy the files Gfp150of.gz and Adr570sa.gz into the directory on the hard disk of the PC. (For example: C:\ADR155c).
- Display the Software Management window.(In the menu bar of the Manager, select the menus: « Tools \ Software Management »).
- Choose the « Update » mode to download the new software.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Select select the soft type: ADRGFP board and the switch type : Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
27 / 22 document.docIssue 2 - 29/08/2011
With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed.It will be restored after the switching of the Motherboard Application code.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Choose the « Switch » mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Select the soft type: Mother board.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the GFP150 (ADRGFP150) board accesses is restored.The traffic of other accesses isn’t interrupted while this command is executed.With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is interrupted while this command is executed. (60 seconds max.).The traffic of other accesses isn’t interrupted while this command is executed.
- Click the « End Session » button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Reserve Download » button to launch the downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Click the « Close » button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
- If GFP150 board(s) is(are) configured in the equipment, it is necessary to do “No Service” then “Service” every board. (Select the GFP150 board then the menu : « Service »)The traffic of GFP150 board(s) is interrupted while this command is executed. (60 seconds max.).
- If the equipment is out of alignment, make an Audit and align the parameters of tabs with a red cross.
3.7 Release P5.6. 1 to P5. 7.0
3.7.1 ADR155c software installation
ADR155c upgrade:
Software (*) Old Code New Code (*)
Motherboard Boot 252 165 976AC-ec 252 165 976AC-ec
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
28 / 22 document.docIssue 2 - 29/08/2011
Motherboard Application 3 000 297 311-rd 3 000 297 311-sa
FPGA Pack 253 349 071AA-we 253 349 071AA-weGFP150 board Application
(ADRGFP150)251 863 036AK-of 251 863 036AK-of
(*): Modified software appears in Bold type
Upgrade procedure with HTTP and a TFTP server for Motherboard software Application:
- Copy the files Adr570sa.gz into the reference (root) directory of the TFTP server. (« IONOS NMS installation directory »\tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server address under « TFTP Server ».
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations ».
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Use the Switching menu to check the version of the downloaded codes.(Select the menu then « Switching »)
Switch (Switch and Reset command) the Motherboard Code. This causes a hot reset.Validate the warning message.The traffic isn’t interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.(Menus: « Up and Download\Download »)
Select the Reload menu then fill the « File » description and select the « Type of Downloaded Informations » (Second download) :
- Download Motherboard Application code : « File » Adr570sa.gz
Click « APPLY » and wait for the information « POST COMPLETED.All data successfully submitted to the device. » (Until 2 minutes per intermediate equipment).
Select the Reload menu then check the downloaded code.The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
If the equipment is out of alignment, make an Audit and align the parameters of tabs with a red cross.
Upgrade procedure with IONOS NMS and a TFTP server for Motherboard software Application:
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
29 / 22 document.docIssue 2 - 29/08/2011
- Copy the file Adr570sa.gz into the directory on the hard disk of the PC. (For example: C:\ADR155c).
- Display the Software Management window.(In the menu bar of the Manager, select the menus: « Tools \ Software Management »).
- Choose the « Update » mode to download the new software.
- Select the equipment to be upgraded with the « Browse » button.
- Tick ADR155c.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the « Browse » button.
- Click the « Show list » button to create the equipment list with the software inventory then on the « Download » button to launch the downloading.The result displays in the Status column.
- Click the « Switch » button to switch the Current and Reserve software.The result displays in the Status column.The traffic isn’t interrupted while this command is executed.
- Click the « Reserve Download » button to launch the second downloading.The result displays in the Status column.
- Click the « End Session » button when the operation is ended.
- Click the « Close » button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs with a red cross.
Document SAGEMCOM - Reproduction et divulgation interditesSAGEMCOM document - Reproduction and disclosure prohibited
30 / 22 document.docIssue 2 - 29/08/2011