adp400 series polarimeters - wilten...

4
Capable of measuring up to 3.0 OD at 589nm over a maximum tube length of 200mm, ADP400 Series polarimeters offer three decimal place precision to an accuracy of ±0.01 °Angular, making them ideal for general purpose use in food, flavours, fragrance, pharmaceutical and chemical industries as well as within academia and research. The ADP400 Series comprises two models: (1) the ADP450 polarimeter with XPC Technology - Xylem’s patented on-board Peltier temperature control system for measuring optically active samples at stable temperatures and (2) the ADP430 polarimeter for use where temperature control is not required or where a waterbath or mathematical compensation is preferred. Both models incorporate an easy-to-use Methods system that gives convenient access to popular measurement types including continual measurement of Optical Rotation, Specific Rotation, Concentration or Inversion. The “single-shot” measurement feature provides a snapshot result at any given time. The ADP400 Series polarimeters come equipped with a new full colour 4” high definition display meaning results are clearly visible to the operator. The expanded memory means that over 8000 measurements and recorded logs of instrument configuration can be saved and viewed or output to LIMS or Secure PDF. Calibration and configuration of the ADP400 can be password protected, accessible by keypad entry or, for convenience, using a fully configurable RFID tag. This, together with the audit trail, facilitates operation in environments conforming to FDA regulation 21 CFR Part 11 or GLP. ADP400 Series Polarimeters HIGH PRECISION, SINGLE WAVELENGTH INSTRUMENTS WITH OR WITHOUT PELTIER TEMPERATURE CONTROL FOR APPLICATIONS WITHIN FLAVOURS, FRAGRANCE, PHARMACEUTICAL, CHEMICAL, ACADEMIA & RESEARCH • Patented XPC Technology • Up to 3.0 OD measurement • Tube lengths up to 200mm • High definition 4“ full colour display • US/EP/BP/JP compliant • Supports FDA regulation 21 CFR Part 11 PHR-MEAN Method with continuous or single-shot measurement modes bioteknika

Upload: vuquynh

Post on 05-Jun-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: ADP400 Series Polarimeters - Wilten Bioteknikawiltenbioteknika.com/.../uploads/2016/09/Bioteknika_Polarimeters.pdf · instruction manual and certificate of conformity. 37-50 ADP450

Capable of measuring up to 3.0 OD at 589nm over a maximum tube length of 200mm, ADP400 Series polarimeters offer three decimal place precision to an accuracy of ±0.01 °Angular, making them ideal for general purpose use in food, flavours, fragrance, pharmaceutical and chemical industries as well as within academia and research.

The ADP400 Series comprises two models: (1) the ADP450 polarimeter with XPC Technology - Xylem’s patented on-board Peltier temperature control system for measuring optically active samples at stable temperatures and (2) the ADP430 polarimeter for use where temperature control is not required or where a waterbath or mathematical compensation is preferred.

Both models incorporate an easy-to-use Methods system that gives convenient access to popular measurement types including continual measurement of Optical Rotation, Specific Rotation, Concentration or Inversion. The “single-shot” measurement feature provides a snapshot result at any given time.

The ADP400 Series polarimeters come equipped with a new full colour 4” high definition display meaning results are clearly visible to the operator. The expanded memory means that over 8000 measurements and recorded logs of instrument configuration can be saved and viewed or output to LIMS or Secure PDF.

Calibration and configuration of the ADP400 can be password protected, accessible by keypad entry or, for convenience, using a fully configurable RFID tag. This, together with the audit trail, facilitates operation in environments conforming to FDA regulation 21 CFR Part 11 or GLP.

ADP400 Series PolarimetersHIGH PRECISION, SINGLE WAVELENGTH INSTRUMENTS WITH OR WITHOUT PELTIER TEMPERATURE CONTROL FOR APPLICATIONS WITHIN FLAVOURS, FRAGRANCE, PHARMACEUTICAL, CHEMICAL, ACADEMIA & RESEARCH

• Patented XPC Technology • Up to 3.0 OD measurement• Tube lengths up to 200mm• High definition 4“ full colour display • US/EP/BP/JP compliant• Supports FDA regulation 21 CFR Part 11• PHR-MEAN Method with continuous or single-shot measurement modes

bioteknika

Page 2: ADP400 Series Polarimeters - Wilten Bioteknikawiltenbioteknika.com/.../uploads/2016/09/Bioteknika_Polarimeters.pdf · instruction manual and certificate of conformity. 37-50 ADP450

ADP400 Series Polarimeters for temperatutre controlled applications

© 2017 Xylem, Inc. All rights reserved. Bellingham + Stanley is a trademark of Xylem Inc. or one of its subsidiaries. ADP400-EN/317

General SpecificationsScales Angular Degrees (°A) International Sugar Scale (°Z) User Scales/Methods

-355 to +355-225 to +225100

Resolution Angular Degrees (°A) International Sugar Scale (°Z)

0.01/0.001 (selectable)

Accuracy Angular Degrees (°A) International Sugar Scale (°Z)

± 0.010± 0.030

Precision (Reproducibility)* Angular Degrees (°A) International Sugar Scale (°Z)

± 0.002± 0.005

User Scales & Methods Library PHR-MEAN statistical, Specific Rotation, Concentration, Inversion (A-B), Invert Sugar and User Defined

Reading Time Continuous measurement and display or single shot (selectable)Tube Length 10 to 200mm Sample Illumination Sodium (589nm) Light Emitting Diode (100,000+ hours)Beam Diameter 4mmOptical Density 0.0 to 3.0 ODInstrument Housing Polyurethane foam with aluminium baseInterfaces 1 x USB (A), 1 x USB (B), 1 x EthernetPower Instrument: 24 V DC, ±5%, <2A

External PSU: 100-240V, 50-60Hz (supplied)Humidity Range <90% RH (non condensing)

Temperature Specifications ADP430 ADP450 (Peltier)Control None or external waterbath Patented XPC TechnologyCompensation None, ICUMSA, Quartz or User DefinedMeasuring Range 5-40 °C 15-35 °CSensor Accuracy ± 0.1 °C ± 0.1 °CStability Waterbath dependent ± 0.2 °CStability Checks None/delay on single-shot None/delay or SMART

Order Codes

Code Description

37-30ADP430 digital polarimeter for use with or without an external waterbath or ATC. Supplied with a standard ICUMSA specification 200mm glass centre fill polarimeter tube, pack of three RFID tags, instruction manual and certificate of conformity.

37-50ADP450 digital polarimeter with patented XPC Technology for constant temperature applications using Peltier devices. Supplied with a standard ICUMSA 200mm stainless steel polarimeter tube and XPC-200 tube adapter, pack of three RFID tags, instruction manual and certificate of conformity.

35-90 Standard ICUMSA stainless steel polarimeter tube - 100mm

35-91 Standard ICUMSA stainless steel polarimeter tube - 200mm

35-95 XPC-100 tube adaptor for use with 100mm standard polarimeter tube

35-96 XPC-200 tube adaptor for use with 200mm standard polarimeter tube

InternationalLongfield Road Tunbridge WellsKent, TN2 3EY United KingdomTel: +44 (0) 1892 500400 Fax: +44 (0) 1892 543115 [email protected]

www.bellinghamandstanley.com

United States90 Horizon Drive Suwanee GA 30024 United States of AmericaTel: 678 804 5730 Fax: 678 804 5729 [email protected]

Latest Software Features

• Save over 8000 readings

• Reading audit trail

• User audit trail

• Configuration audit trail

• Print to secure PDF

• Simple USB “Back-up & Clone”

• User maintenance prompts

ADP400 displaying reading parameters at 20°C

PHR-MEAN Method provides full statistical analysis of a multi-point experiment

Intelligent software shows real-time validation and maintenance information

Wilten Bioteknika | T +31 76 508 65 00 | E [email protected] | W www.wiltenbioteknika.com

Page 3: ADP400 Series Polarimeters - Wilten Bioteknikawiltenbioteknika.com/.../uploads/2016/09/Bioteknika_Polarimeters.pdf · instruction manual and certificate of conformity. 37-50 ADP450

ADP600 Series PolarimetersHIGH PRECISION, MULTI-WAVELENGTH PELTIER TEMPERATURE CONTROLLED MODELS

FOR PHARMACEUTICAL, CHEMICAL, FOOD & RESEARCH APPLICATIONS

Available as single, dual and multiple wavelength derivatives covering the visible spectrum, the ADP600 Series also features measurement in the highly sensitive ultra-violet region. This capability makes the instrument particularly suited for use by scientists wishing to measure chiral compounds and other optically active substances in the chemical, pharmaceutical and food sectors as well as for use in academic research.

Integral to operational simplicity is the full color, high definition touch-screen graphical user interface. A simple menu structure featuring a METHOD system is similar to the popular wide range RFM series of Peltier controlled refractometers commonly found across industry.

ADP600 polarimeters have an extensive interfacing capability and may be configured to operate in secure environments in accordance with FDA regulation 21 CFR Part 11 and also meet the requirements of US, European and Japanese pharmacopoeia.

A full range of accessories is available including low volume, standard and flow through sample tubes as well as UKAS certified quartz control plates that are traceable to PTB, used to verify instrument performance.

• Single,dual&multiplewavelengthmodels

• Fourdecimalplaceresolution

• Peltiertemperaturecontrolled

• Highdefinition7.4“touch-screendisplay

• US/EP/BP/JPcompliant

• SupportsFDAregulation21CFRPart11

• SimpleMethodsystem

• Acceptsstandard&lowvolumesampletubes

bioteknika

Page 4: ADP400 Series Polarimeters - Wilten Bioteknikawiltenbioteknika.com/.../uploads/2016/09/Bioteknika_Polarimeters.pdf · instruction manual and certificate of conformity. 37-50 ADP450

ADP600 Series of Peltier Controlled Polarimeters

©2014Xylem,Inc.Allrightsreserved.Bellingham+StanleyisatrademarkofXylemInc.oroneofitssubsidiaries. ADP600-EN/914

General Specifications Range (°A) ± 89 (-355 to +355 via Method selection) (-225 to + 225 °Z)

Resolution (°A) 0.0001

Accuracy (°A) ± 0.003 (@546 & 589nm) / ± 0.005 (@325, 365, 405 & 436nm)

Temperature Range 15-35°C

Temperature Control / Accuracy Peltier / ± 0.2°C

Temperature Compensation None, sugar, quartz, user defined

Optical Density Range 0.0 to 3.0 OD

Methods Specific Rotation, % Concentration, Purity, % Invert Sugar, % Inversion (A-B)

Temperature Set Points 20 & 25 °C (variable between 20-30 °C via Method)

Reading Time 15-60 seconds @ 546/589nm and 20/20°C (instrument/sample)

Tube Length 5-200mm

Tube Diameter 3-8mm

User Interface High Definition 7.4” touch-screen color display

Light Source UV/Vis lamp (6V, 2A >1000hrs) and narrow band pass filter(s)

Interfaces 3 x USB (A), 1 x USB (B), 1 x Ethernet, 1 x RS232

Power Supply 100-250V~, 50-60 Hz. <6A.

Order CodesCode Description Wavelength(s)

37-61 ADP610 single wavelength polarimeter supplied with pack of two RFID tags, standard lids, instruction manual and certificate of calibration. 589nm

37-62 ADP620 dual wavelength polarimeter supplied with pack of two RFID tags, standard lids, instruction manual and certificate of calibration. 546 & 589nm

37-63 ADP622 dual wavelength polarimeter supplied with pack of two RFID tags, standard lids, instruction manual and certificate of calibration. 365 & 589nm

37-64 ADP640 multiple wavelength polarimeter supplied with pack of two RFID tags, standard lids, instruction manual and certificate of calibration. 405, 436, 546 & 589nm

37-65 ADP650 multiple wavelength polarimeter supplied with pack of two RFID tags, standard lids, instruction manual and certificate of calibration. 365, 405, 436, 546 & 589nm

37-66 ADP660 multiple wavelength polarimeter supplied with pack of two RFID tags, standard lids, instruction manual and certificate of calibration.

325, 365, 405, 436, 546 & 589nm