  • 8/9/2019 Additel Log II Manual_en-US

    1/16

    Additel/Log II Data LoggingSoftware

    User Manual

    Additel Corporation

    2012-01

  • 8/9/2019 Additel Log II Manual_en-US

    2/16

    2/ 16

    ContentsChapter One: Preface ......................................................................................................... 3

    1. Company Introduction ................................................................................................ 32. Features of Additel/Log II .......................................................................................... 4

    3. System Requirements .................................................................................................. 5

    4. Software Installation ................................................................................................... 6Chapter Two: Functions

    .................................................................................................. 91.Port Setting ................................................................................................................. 10

    2.Collect Setting ............................................................................................................ 113.Start or Stop ............................................................................................................... 12

    4.Data Export ................................................................................................................ 14

    5.Database Manager ...................................................................................................... 16

  • 8/9/2019 Additel Log II Manual_en-US

    3/16

    3/ 16

    Chapter One: Preface

    1. Company Introduct ion

    As one of the leading worldwide providers of process calibration tools, the

    Additel Corporation has been dedicated to the design and manufacture of high-

    quality handheld test tools and portable calibrators for process industries and

    OEM industries in precision pressure calibration and test instrumentation.

    Throughout the years, Additel has successfully developed Handheld Automated

    Pressure Calibrators, Precision Pressure Calibrators, Documenting Process

    Calibrators, Multifunction Process Calibrators, Multifunction Temperature

    Calibrators, Precision Digital Pressure Gauges and various Test Pumps andHand Pumps. These products are widely used in over 30 countries throughout

    the world.

    Product quality and customer service along with innovative engineering

    have been top priorities of the Additel business philosophy. We are committed to

    customer satisfaction through cost-competitive quality products, services, and

    technical support.

  • 8/9/2019 Additel Log II Manual_en-US

    4/16

    4/ 16

    2. Features of Additel/Log II

    Additel/Log II is an application software specializing in real time monitoring anddata collection towards pressure gauges, an absolute necessity of pressurecalibration.

    Main Functions:

    Graphical interface display and data collection

    Additel/Log II will collect data (pressure values) and display through clear

    graphic control, when the serial port communication is normal.

    Data collection and long-lasting saves

    Additel/Log II will collect data in real time and save it to the database for

    further analysis. Supports data export

    Additel/Log II can export collected data in EXCEL according to the name of

    the equipment and collection time.

  • 8/9/2019 Additel Log II Manual_en-US

    5/16

    5/ 16

    3. System Requirements

    Hardware Requirements

    CPU: Inter Pentium III aboveMemory: 512MB above

    Hard Disk: 2GB above

    Hardware should support serial port

    Software Requirements

    Operation System:

    Windows 2000 SP4/Windows XP SP2/Windows 2003/Windows

    Vista/Windows7

  • 8/9/2019 Additel Log II Manual_en-US

    6/16

    6/ 16

    4. Software Installation

    First, double click Setup.exe in the installation disk menu, as follows:

    Figure 1-1

    If the system has not installed microsoft .net Framework 2.0, installation will be

    prompted, as follows:

    Figure 1-2

    Second, a welcome interface will appear, as follows.Press Next.

    Figure 1-3

  • 8/9/2019 Additel Log II Manual_en-US

    7/16

    7/ 16

    Third, choose a folder to install, as follows.Press Next.

    Figure 1-4

    Fourth, a confirmation message window will appear as follows. Press Next to

    begin the installation

    Figure 1-5

  • 8/9/2019 Additel Log II Manual_en-US

    8/16

    8/ 16

    Fifth,installing Additel Log II

    Figure 1-6

    After the installation complete.Click Close to finish the process installation.

    Figure 1-7

  • 8/9/2019 Additel Log II Manual_en-US

    9/16

    9/ 16

    Chapter Two: Functions

    Click the Additel Log II shortcut, then the main interface will be shown,as follow

    Figure 2-1

    If the connection fails, the information boxes will be blank.

    The port connection must be successful in order to view the calibrator values

    in the information boxes.

  • 8/9/2019 Additel Log II Manual_en-US

    10/16

    10/ 16

    1.Port Setting

    Click Port Setting on the main interface to enter the tool box as follow:

    Figure 2-2

    The communication configuration of serial port,as follows:

    PortName Address BaudRate DataBits Parity StopBits

    default COM1 1~255

    (default 1)

    4800

    9600

    14400

    19200

    (Default 9600)

    8 None Two

    Users can edit serial PortName, BaudRate and Address according to

    different calibrators situation. Pressing scan can check the communication

    between computer and calibrator is normal or not.

  • 8/9/2019 Additel Log II Manual_en-US

    11/16

    11/ 16

    2.Collect Setting

    Click the Collect Setting in the main interface to enter the tool box as follow:

    Figure 2-3

    Users can set the total time and interval to collect data.

    If the total time is set to zero, then the device will not auto-stop after clicking

    the start in the main interface.

    The system default setting total time is 1 hour; default collection interval is 5

    seconds.

    After the setting, click OK to finish the collect setting.

  • 8/9/2019 Additel Log II Manual_en-US

    12/16

    12/ 16

    3.Start or Stop

    After the data of the Port setting and Collect setting is confirmed, click startin the main interface collection task.

    Figure 2-4

    If you are not satisfied with the collected data, click Clear to delete the

    previously collected data and the system will automatically begin a new

    collection task.

    Additel/Log II will collect data in real time and save it to the database for

    further analysis.

    Once the Total Time is completed, the collection task will end automatically.

  • 8/9/2019 Additel Log II Manual_en-US

    13/16

    13/ 16

    Click "Stop" to stop the collection task.

    Figure 2-5

  • 8/9/2019 Additel Log II Manual_en-US

    14/16

    14/ 16

    4.Data Export

    When the collection task is completed, the collected data can be exported to thePC. Click Export in the Main Interface and the Data Management window willopen. Now you can chose among three formats: Excel, XML and CSV. Thenclick Finish.

    Figure 2-6

    Data Search

    The system provides the function of database search according to the searchconditions set by the user and displays the results in the data list as shown infigure 2-6.

  • 8/9/2019 Additel Log II Manual_en-US

    15/16

    15/ 16

    Export Format

    Additel/Log II provides three data derivation formats:

    XML Spreadsheet Format

    This is an XML document format which can save format spreadsheet data

    quickly without the support of other groupware. It can be read by EXCEL.

    EXCEL Book Format

    This is an EXCEL standard format XLS document which can save format

    spreadsheet data at low speeds with the support of MDAC groupware.It can

    be read by EXCEL.

    CSV Format

    CSV document is a text document. It can be derive very fast and take only a

    little space and doesnt need other groupware support. This document can

    be read by EXCEL or any other document reader. When the derivation data

    exceeds 65000 rows, more derivations can be generated.

  • 8/9/2019 Additel Log II Manual_en-US

    16/16

    16/ 16

    5.Database Manager

    Figure 2-7

    Users can backup all collection-data to a file.

    Users can recover collection-data from a backup file.

    Users can clear collection-data with collect-time.