ADDENDUM NO. 2
Project No. PTC 2019-17D November 20, 2019.
Project: ROSEDALE RENOVATION – 19007
90 CHAPPLE STREET
SAULT STE. MARIE, ONTARIO The following additions, deletions, and amendments are hereby made a part of the drawings and specifications of the above project.
The Tender and Bid documents are hereby amended as per MGP Architects and Engineer
Project No. 19007 - Addendum No.2 attached.
Liza Chikoski, A.Sc.T. Infrastructure & Asset Manager
Housing | Social Services
P.O. Box 277 | 180 Brock Street
Sault Ste. Marie, Ontario, P6A 5L8
CA
Phone: 705-759-5131
Fax: 705-759-5212
Cell:
Email: [email protected]
Web: http://www.socialservices-ssmd.ca
![Page 2: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/2.jpg)
MGP ARCHITECTS·ENGINEER INC ADDENDUM NO. 2 19007 PAGE 1 OF 15 Project Title: ROSEDALE RENOVATION 90 CHAPPLE STREET SAULT STE. MARIE, ONTARIO Date: NOV. 19, 2019 The following revisions and supplementary instructions shall be part and parcel of the Tendering Documents and shall supersede the Drawings and/or Specifications where applicable. ARCHITECTURAL INFORMATION
Existing Wall Penetrations .1 Even though not noted on drawings, existing wall penetrations / voids in existing walls are to be infilled with similar material. Note that these locations are primarily at removed existing electrical & mechanical ducts / conduits that have been removed. Infill to provide smoke seal only. Also note that fire stopping required at location of fire separations (Drawing A1.1)
.2 As indicated at site visit, General Contractors to be aware that
previous roofing contract is on-going. As also noted, roofing allowance in this tender for existing roofing contractor to complete all requirements.
CLARIFICATION
Drawing A7.7 .1 Porcelain Tile designation (Floor Type Legend) shown as a darker line as opposed to the Vinyl Composite Tile (Field)
.2 In determining the extent of existing walls that are to receive new
drywall, refer to floor plan drawings A2.2 – A2.6 for locations of wall designations P4, P5, P6, P7
SPECIFCATIONS
Division 0 Instruction to Bidders 4.2.3 Performance Security: Delete reference to “… retaining for a period of two (2) years and replace with a period of one (1) year.
Division 15 Supplementary General 3.2 Commercial General Liability Insurance Refer to Article 3.
Conditions AddSentence 3.3 to read: “Broad form” property insurance outlined in CCDC-2 2008 Stipulated Price Contract, GC 11.1.1.4 and CCDC 41 CCDC Insurance Requirements, Article 4, shall be provided, maintained and paid for by the Owner”.
Section 06410 Cabinetwork 2.5 Plywood Construction: 5/8” (16mm) is acceptable alternative.
Section 07200 Insulation 2.2 Adhesives & Fasteners: Resisto – Chem-link M1 Structural
Adhesive is an acceptable alternative. Section 10001 Miscellaneous Specialties 4.2 7001 series access ladder (Skyline Group) is acceptable
alternative. (SG394 non-penetrating hatch barrier NOT approved.) No hatch barrier required – Bidders instructed to bid as specified.
Section 10800 Washroom Accessories 2.2 See attached document for list of accessories and required
locations.
2.2.5 No Tilt Mirrors required: standard mirror to be installed at required mounting height for Barrier Free areas.
CIVIL
.1 DRAWING C2.0 Details / Sections Rev.2 1.0 Replace drawing with C2.0 Rev 2 attached. .2 DRAWING C4.0 Site Plan Rev.1 1.0 Replace drawing with C4.0 Rev 1 attached.
All sidewalks except along the south side parking are flush with asphalt. Where the sidewalk is to be 150mm above the asphalt, provide a club as shown in Section 5 on the revised drawings.
![Page 3: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/3.jpg)
MGP ARCHITECTS·ENGINEER INC ADDENDUM NO. 2 19007 PAGE 2 OF 15 MECHANICAL CLARIFICATIONS .1 General contractor to disconnect and remove abandoned boilers and
associated piping, controls and natural gas piping. Owner shall have first right of refusal.
.2 Disconnect & remove existing standpipe system assembly, fire hose cabinets, associated piping back to source in its entirety. General contractor to patch and make good surfaces. Division 15 to coordinate with G.C. .1 DRAWING M0.3 .1 Addition of pex piping support detail. Refer to attached drawing M0.3-AD2.
.2 DRAWING M1.0 .1 Main Floor Sanitary & Drainage Deconstruction Plan. Refer to attached drawing M1.0-AD2 for additional removals.
.3 DRAWING M3.0 .1 Corridor 303: Add 12”x12” return air grilles. Refer to attached drawing M3.0-AD2. .4 DRAWING M4.1 .1 Booster fan identified for washer/dryer in 2 Bedroom Type B and 1 Bedroom Type E to read: EF-12 as indicated in Schedule of Miscellaneous Fans dwg. M0.2. .5 DRAWING M4.2 .1 Eggcrate grille in Men’s WR 206 and Women’s WR 208 to be Nailor Type 61EC. .6 DRAWING M6.1 .1 Storage room below Office 203A to be included as part of fire protection. Refer to attached drawing M6.1-AD2. ELECTRICAL
.1 DRAWING E0.1 .1 Electrical Product Schedule: Revise Product Fixture Schedule schedule as follows: Type ‘A1’:
14ӯ low profile round flush mount c/w white acrylic diffuser, 1600 lumens, 80CRI, 4000K, 120V, CSA certified
Product shall be equal to Lithonia Model FMLRL 14 20840 M4 c/w DFMLRL 14 CSA Type ‘A2’:
Triple pendant led luminaire, dimmable, 4”OD x 11.75” H, 13W, AC LED, 120V, 40K, 1000 lumens, satin white finish, CSA certified. Mounting heights to be determined on site.
Product shall be equal to Bock Lighting Model A30111945041 LAC01-13W c/w SPC 3 stem canopy CSA Type ‘A4’: New construction, recessed, waterproof shower potlight by Div. 15. Type ‘B1’:
2’ long traditional vanity fixture, 120V, 20W, 4000K, 1200 lumens, 80CRI, brushed nickel finish, horizontal mount, CSA certified.
Product shall be equal to Magic Lite Model VNL-20-40K-BN CSA Type ‘B2’:
Large LED wall luminaire, 19W, 1528 lumens, impact resistant, 4000K, black finish, 120/277V, suitable for wet locations c/w 4” mounting plate, CSA certified
Product shall be equal to Ligman Model UAUG-30021 19W W40 01 120/277v-4MP CSA Type ‘C1’:
8ӯ wet location thin-line down lights, 19W, 80CRI, natural white, 120V, CSA certified
Product shall be equal to Magic Lite Model LVDL-W-08-NW-WH CSA.
![Page 4: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/4.jpg)
MGP ARCHITECTS·ENGINEER INC ADDENDUM NO. 2 19007 PAGE 3 OF 15 Type ‘C2’:
LED rated high bay LED, 18000 lumens, clear polycarbonate deflector, open bottom, MVOLT, 0-10V dimming, 40K, 80CRI, mounted to u/s of roof deck, natural aluminium finish, safety hook, male, cast aluminium, wire guard for use with open bottom deflectors, CSA certified
Product shall be equal to Lithonia Model JCBL 18900LM PLCR MVOLT GZ10 40K 80CRI PM 3C6 DNAXB HK-455 WGJCBL CSA Type ‘C3’:
6ӯ recessed LED module, matte white finish, HL LED, 4000K, 90CRI, 950 lumens, 16.4W, 120V, new construction rough-in LED base, clear specular diffuser with matte white trim ring, CSA certified
Product shall be equal to Lithonia Model 60PAZ TRMW HL LED 120V L7X LED24 CSA Type ‘D4’:
LED lensed striplight, 48” long, no reflectors, 52W, 5000 lumens, snap on frosted diffuser/lens, MVOLT, 4000K, 80CRI, white, CSA certified
Product shall be equal to Lithonia Model ZL1N L48 5000LM FST MVOLT 40K 80CRI WH CSA Type ‘D5’:
LED lensed striplight, 48” long, no reflectors, 52W, 5000 lumens, snap on frosted diffuser/lens, MVOLT, 4000K, 80CRI, white wireguard as noted, 10’ aircraft cable for pendant mounting as noted, CSA certified
Product shall be equal to Lithonia Model ZL1N L48 5000LM FST MVOLT 40K 80CRI WH ZACVH WGZ48 CSA Type “D8”: Not applicable (no longer in use) Type ‘D9’:
Slot 6 LED recessed linear luminaire, linear optimized plan, 4 feet long, flush lens, 5/8” flange, 80CRI, 900 lumens per foot, standard distribution, no dimming, 120V, CSA certified Product shall be equal to Metalumen Model SL6L LOP 4FT FL 80CRI 40K 900LMF NODIM 120V WL CSA
Type ‘D10’:
LED rail pendant luminaire, 4000K, Meta Ice, (high output semi-diffuser), 4 feet long, flush lens, 5/8” flange, 90CRI, 4000K, 900 lumens/ft, non-dimming, 120V, wet location listing, CSA certified Product shall be equal to Metalumen Model S6 1L40K 4G SA L3 1 PA 4 90 CSA Type ‘D11’: 1’x4’ edge lit flat panel LED, recessed luminaire, for installation in T-bar ceiling, 4000 lumens, 4000K, 80CRI, 38.5W, satin white lens, 120V, MVOLT, CSA certified Product shall be equal to Lithonia Model EPANL 1x4 40L 80CRI 40K MVOLT CSA Type ‘F1’: D series Size 0, single head, P5 forward throw optics, 4000K, forward throw medium distribution, MVOLT, round pole mounting, photocell, black finish c/w 20’-0” 5”Ø round pole c/w house shield, CSA certified Product shall be equal to Lithonia Model DSX) LED P5 4000K TFTM MVOLT RPA HS DDBXD c/w HS 40CU Type ‘F2’: LED small wallpack WST LED. 6000 lumens, 4000K, visual comfort throw forward, 50W, MVOLT, black finish, photocell, CSA certified Product shall be equal to WST LED P3 40K VW MVOLT BBW PIRH DBLXD
![Page 5: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/5.jpg)
MGP ARCHITECTS·ENGINEER INC ADDENDUM NO. 2 19007 PAGE 4 OF 15
Type ‘F3’: Large LED wall luminaire, 19W, 1528 lumens, impact resistant, 4000K, black finish, 120/277V, suitable for wet locations c/w 4” mounting plate, CSA certified
Product shall be equal to Ligman Model UAUG-30021 19W W40 01 120/277V-4MP CSA Type ‘F4’:
Radean post mounted LED area luminaire, 10,000 lumens, 4000K, symmetric type V distribution, MVOLT, mounting 0 slips inside a 4”Ø round metal pole, button photocell, 14’ round straight pole (4” OD), black finish c/w house shields, CSA certified Product shall be equal to Lithonia Model RADPT P4 40K SYM MVOLT PT4 PE RADCS RSS14 DBXLD Dimmable Light Switch: Product shall be equal to Acuity Control (ensure switch is compatible with luminaire lighting manufacturer’s recommendations) Model nPODM-DX-WH c/w Power Pack
.2 DRAWING E0.7 .1 Detail 1 Site Lighting Photometry Plan: Revise Detail bubble to read Drawing E0.7 Delete all reference to light fixtures type ‘C2’ in West canopy typ. of 8) .3 DRAWING E1.6 .1 Addition of Detail 3 Electrical Deconstruction Plan: Refer to attached drawing E1.6-AD2 .4 DRAWING E2.4 .1 Detail 1 Partial Ground Floor West Wing Lighting Plan: Refer to attached drawing E2.4-AD2 .2 Detail 2 Partial Ground Floor West Wing Lighting Plan: Refer to attached drawing E2.4-AD2 .5 DRAWING E2.5 .1 Detail 1 Partial Ground Floor Daycare Lighting Plan: Refer to attached drawing E2. Attachments: WASHROOM ACCESSORY REVISED Drawing C2.0 Details/Sections Rev.2 Drawing C4.0 Site Plan Rev.1 Drawing M0.3-AD2 Drawing M1.0-AD2 Drawing M3.0-AD2 Drawing M6.1-AD2 Drawing E1.6-AD2 Drawing E2.4-AD2 Drawing E2.5-AD2 END OF ADDENDUM
![Page 6: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/6.jpg)
SECTION 10800 - WASHROOM ACCESSORIES REVISED
PROJECT NO. PTC 2019-17D 10800-1
PART 2 - PRODUCTS 2.2 WASHROOM ACCESSORIES
.1 Toilet paper dispenser (TPD-A): Frost #1135-S single roll dispenser. LOCATION: Rooms 110, 115, 122, 301, 304, 305, 306, 307, 401, 402,405, 406 .
.2 Toilet paper dispenser (TPD-B): San Jamar, 9” JBT Oceans Dispenser #R2090TBK. LOCATION:
Rooms 120, 127, 129, 206, 208, 225, 226.
.3 Paper towel dispenser (PTD): NPS Corp., Response HRT Lever dispenser, hard roll towels up to 8” dia. LOCATION: Rooms 120, 127, 129, 206, 208, 225, 226.
.4 Hand dryer (HD): ASI Model # 0185, 115 V, Surface mounted, one piece 16 ga. steel cover with
white enamel finish, infra red sensor, fixed directional air vanes. LOCATION: Rooms as noted on Mechanical Drawings.
.5 Mirrors: No. 1 quality, 6 mm thick glass mirror, heavy galvanized steel back; stainless steel frame with mitred corners, tamperproof mounting.
.1 Mirror (MR.1): Frost 941-1830, 18” x 30” metal framed mirror, vandal resistant mounting.
LOCATION: Rooms 120, 127, 129, 206, 208, 225, 226.
.2 Mirror (MR.2): 2" (50 mm) frame, allow for single frame colour to later selection from
manufacturer’s complete colour range. Size: 48" (1220 mm) wide x 36" (915 mm) high,
concealed mounting. Mounting height(s): at accessible lavatories, set bottom edge at top of
vanity backsplash; at other lavatories, set bottom edge 42" (1067 mm) above the floor.
Canadian Hotel Supply Company, Vanity Mirror 48 Inch x 36 Inch #57680454836,
or equivalent. LOCATION: Rooms 301, 304, 305, 306, 307, 401, 402,405, 406.
.6 Robe hook (RH): Frost 1138-S, heavy duty, stainless steel, concealed mounting. 16 ga. type 304
stainless steel, No. 4 brushed finish, concealed mounting. Mounting height: top of coat hook 3'-11" (1200 mm) LOCATION: Rooms 120, 127, 129, 206, 208, 225, 226, 301, 304, 305, 306, 307, 401, 402, 405, 406.
.7 Grab bars (GB): Frost, 1 ½” diameter, stainless steel, satin finish, concealed mounting, meeting
requirements of OBC and as follows: .1 GB1: 1001-NP-24” straight .2 GB2: 1003-NP-30 X 30” L-shaped LOCATION: Rooms 206, 208, 401, 402, 405.
.8 Recessed Soap Dish: 7-1/4" (188 mm) long x 5" (127 mm) high x 2-5/8" (67 mm) deep one piece
drawn seamless heavy gauge stainless steel with 18 ga. stainless steel drip lip and mortar lugs for
anchorage with cement, satin finish. Mounting Height: bottom edge 36" (914 mm) above the floor and
reachable from seated position. Frost Products Ltd., 1132HD Recessed Soap Dish, Heavy Duty.
LOCATION: Rooms 301, 304, 305, 306, 307, 401, 402,405, 406.
.9 Shelf - SH (Rooms A-109, B-113): surface-mounted, 22 ga. stainless steel, No. 4 brushed finish, 18" (457 mm) long, rounded corner shelf welded to wall plate. Mounting height: 3'-3" (1000 mm) A.F.F. Frost Products Ltd., 950-4 Heavy Duty Shelf, or equivalent. LOCATION: Rooms 206, 208, 401, 402, 127, 129.
![Page 7: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/7.jpg)
SECTION 10800 - WASHROOM ACCESSORIES REVISED
PROJECT NO. PTC 2019-17D 10800-2
.10 Shower Curtain Rod - SCR: 1-1/4" (32 mm) diameter, lengths to suit tub and shower compartment
openings; type 304 stainless steel with No. 4 brushed finish; 16 gauge drawn type 304 3" (76 mm)
diameter stainless steel flanges; flanges are mounted to wall with stainless steel countersunk
screws. Mounting height: 6'-4" (1930 mm) above the floor. Frost Products Ltd., 1145 Stainless Steel
Shower Rod, or equivalent. LOCATION: Rooms 301, 304, 305, 306, 307, 401, 402, 405, 406.
.11 Towel Bar - TB: type 304 stainless steel, No. 4 brushed finish, 3-1/2" (89 mm) wall clearance,
concealed mounting. Mounting height: 3'-3" (1000 mm) A.F.F. Frost Products Ltd., 1141S Towel
Bar, or equivalent. LOCATION: Rooms 301, 304, 305, 306, 307, 401, 402, 405, 406.
.12 Soap Dispenser – SD: Bradley type 6562 stainless steel, 20 gauge, 40 oz reservoir, concealed
mounting, vandal resistant filler hole cover, or equivalent. Mounting height: max 4’-0” (1200) AFF or
3’-8” (1120) max AFF if counter depth greater than 20” – 25” (508 – 635)
3.3 SCHEDULE
.1 Unless otherwise shown:
.1 Install toilet paper dispenser at each WC.
.2 Provide paper towel dispenser at each washroom.
.3 Provide framed mirror at each washroom, in location shown; where no location shown, install above lavatory.
.4 Provide mirrors as indicated.
.5 Provide grab bars at all WC's for barrier free access.
.6 Provide robe hook at all toilet stalls and where shown.
.7 Install soap dispenser at each lavatory.
END
![Page 8: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/8.jpg)
number
ARCHITECTS
revisions
N
MGP
INC.ENGINEER
ROSE
DAL
E RE
NO
VATI
ON
for S
SM H
OU
SIN
G C
ORP
.90
CH
AP
PLE
AV
EN
UE
SA
ULT
STE
. MA
RIE
, ON
C2.0
DETAILS & SECTIONS
DETAIL-SANITARY CLEANOUT
SECTION- BLD. ENTRANCE
DETAIL-CONCRETE SLAB JOINT
DETAIL-BARRIER CURB (OPSD 600.110)
SECTION-PARKING LOT STRUCTURE
SECTION-PIPE BEDDING
SECTION- STEP JOINT
SECTION-THICKENED ASPHALT EDGE
DETAIL-STAIRS SECTION- RETAINING WALL
DETAIL- CONCRETE SIDEWALK-CURBING
Nov 19/19
![Page 9: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/9.jpg)
number
ARCHITECTS
revisions
N
MGP
INC.ENGINEER
ROSE
DAL
E RE
NO
VATI
ON
for S
SM H
OU
SIN
G C
ORP
.90
CH
APPL
E AV
ENU
ESA
ULT
STE
. MAR
IE, O
N
C4.0
SITE PLAN & SERVICES
EX. BUILDINGFF=228.410
BY PERMITONLY
SIGN LEGEND
NOTES
PAINTING
Nov 18/19
![Page 10: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/10.jpg)
PLUMBING DETAILS
number
revisions
DA
YC
AR
E /
EA
RLY
ON
CE
NTR
ER
OS
ED
ALE
PU
BLI
C S
CH
OO
Lfo
r S
SM
HO
US
ING
CO
RP
OR
ATI
ON
90 C
HA
PP
LE A
VE
NU
E
M0.3-AD2
![Page 11: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/11.jpg)
DEMOLITIONDEMOLITION
number
revisions
MAIN FLOOR SANITARY &DRAINAGE PIPINGDECONSTRUCTION PLAN
M1.0-AD2
![Page 12: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/12.jpg)
NEW APARTMENTSNEW APARTMENTS
number
revisions
MAIN FLOORHVAC DUCTWORK PLAN
M3.0-AD2
![Page 13: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/13.jpg)
NEW APARTMENTSNEW APARTMENTS
number
revisions
MAIN FLOOR OPERATIONSFIRE PROTECTION PLAN
M6.1-AD2
![Page 14: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/14.jpg)
number
ARCHITECTS
revisions
N
MGP
INC.ENGINEER
DA
YC
AR
E /
EA
RLY
ON
CE
NTR
ER
OS
ED
ALE
PU
BLI
C S
CH
OO
Lfo
r S
SM
HO
US
ING
CO
RP
OR
ATI
ON
90 C
HA
PP
LE A
VE
NU
E
GROUND FLOOR EARLY STARTPOWER/TELECOMMUNICATION/FA, ELEC RM 209/IT RM 210 ANDELECTRICAL DECONSTRUCTIONPLANS
E1.6-AD2
2
![Page 15: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/15.jpg)
R
number
ARCHITECTS
revisions
N
MGP
INC.ENGINEER
DA
YC
AR
E /
EA
RLY
ON
CE
NTR
ER
OS
ED
ALE
PU
BLI
C S
CH
OO
Lfo
r S
SM
HO
US
ING
CO
RP
OR
ATI
ON
90 C
HA
PP
LE A
VE
NU
E
PARTIAL GROUND FLOORWEST WINGLIGHTING PLANS
E2.4-AD2
2
2 2
2
2
2
2
![Page 16: ADDENDUM NO. 2 Project No. ROSEDALE RENOVATION 90 … · line as opposed to the Vinyl Composite Tile (Field) .2 In determining the extent of existing walls that are to receive new](https://reader033.vdocuments.us/reader033/viewer/2022042712/5f8d43ae6a9768030712fbb6/html5/thumbnails/16.jpg)
number
ARCHITECTS
revisions
N
MGP
INC.ENGINEER
DA
YC
AR
E /
EA
RLY
ON
CE
NTR
ER
OS
ED
ALE
PU
BLI
C S
CH
OO
Lfo
r S
SM
HO
US
ING
CO
RP
OR
ATI
ON
90 C
HA
PP
LE A
VE
NU
E
PARTIAL GROUND FLOORDAYCARE LIGHTING PLAN
E2.5-AD2
2
2
2
2
2