addendum no. 2correct and/or change the contract documents to the extent indicated and is hereby...
TRANSCRIPT
7600 Dublin Blvd., 3rd Floor, Dublin, CA 94568
CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT
Bid No.: B19/20-04
B2420 A/V Wall Replacement – Las Positas College
Addendum No. 2
NOTICE TO ALL CONTRACTORS SUBMITTING BIDS FOR THIS WORK AND TO ALL PAN HOLDERS: You are hereby notified that this Addendum No. Two is issued to clarify, add, delete, correct and/or change the contract documents to the extent indicated and is hereby made a part of the above noted contract documents on which the contract will be based. Any modifications/changes made by this addendum affect only the portions or paragraphs specifically identified herein; all remaining portions of the proposal to remain in force. It is the responsibility of all bidders to conform to this addendum. Acknowledge receipt of this addendum in the space provided on the bid form. Failure to do so may subject Bidder to disqualification.
A. CHANGES AND/OR CLARIFICATIONS: Item One (1) REVISION: Division 00 Procurement and Contracting Requirements, Special Conditions – Replace in its entirety Section 3 Contract Time, Liquidated Damages, Items 3.1 Contract Time and 3.2 Milestones to read as follows: 3.1 Contract Time The Contract Time for the Contractor’s Substantial Completion
of the Work is Eighty-Six (85) Calendar days after the date for commencement of the Work as set forth in the Notice to Proceed issued by or on behalf of the District to the to the Contractor. The anticipated Notice to Proceed date of October 17, 2019
3.2 Milestones
3.2.1 Submittal Phase: October 17, 2019 to December 6, 2019 3.2.2 Construction Phase: December 16, 2019 to January 6, 2020 3.2.3 Punch List and Closeout Phase: January 7, 2020 to January 10, 2020
7600 Dublin Blvd., 3rd Floor, Dublin, CA 94568
Item Two (2) REVISION: Specification Section 27 41 16 – Replace in its entirety Section 1.05 B, Item 3 Video to read as follows:
a. Provide direct-view LED display, video-wall processor, backing,
accessories, and spares as recommended by the manufacturer
(typically 5%). Provide factory commissioning and check out for
acceptance. Refer to master quote and contact information below:
• DigiLED
• Salvador Sandoval
• Technical Sales Manager – Americas
• Mobile - 209.210.7928 USA
• Email - [email protected]
• Web www.digiLED.com
• Master Quote Reference: TeeCom SQ-TE-13-digiTHIN HD1560-F-18842
b. Provide video matrix switch.
c. Provide input and output modules for the video matrix switch.
d. Provide HDBaseT transmitter.
e. Provide the following connections at the lectern: USB (for charging only),
HDMI, DisplayPort, two data jacks and VGA with analog audio.
f. Provide cable retractors.
g. Install an Owner-furnished PC onto the lectern monitor arm.
h. Provide document camera.
i. Provide wireless presentation systems.
j. Provide lecture capture system.
k. Provide multi-window processor for the lecture capture system. Set presets
so that users can recall them on touch panel controller.
l. Provide PTZ cameras. Three of the cameras will capture a section of the
whiteboards in front of the lecture hall. One camera will be used for capturing
the instructor. One camera will capture the audience.
m. Program the cameras for specific preset functions.
n. Provide a camera system that automatically tracks instructors. Include the
following capabilities:
7600 Dublin Blvd., 3rd Floor, Dublin, CA 94568
• Create detection zones. As instructors move into each zone, the
camera will follow them.
• Orient both tracking sensors so that the tracking planes are inclined
and completely cover the lecture hall instructor well.
o. Provide an HDMI distribution amplifier.
p. Provide an AV bridge.
q. Provide USB transmitter and receiver.
r. Provide confidence monitor. Confidence monitor will show the video that is
currently showing on the videowall and/or an instructor self-view.
s. Provide wall mount for the confidence monitor.
Item Three (3) REVISION: Specification Section 27 41 16 – Replace in its entirety Section 1.05 B, Item 4 Control to read as follows: 4. Control
a. Programming of the control systems is to be provided by a specialized 3rd party firm under the contract and management of the AV contractor.
b. Specialty control is to include integration of video bridge system and peripherals, Zoom collaboration and peripherals, and all the functionality associated with the audiovisual systems in the project.
• 3rd party programming firm:
• PepperDash
• Howard Nunes, President/CEO
• Email: [email protected]
• Direct: 617.206.9813
• Mobile: 781.910.3222
• Master Quote Reference: TEEC005 – Las Positas College – interactive classroom 2420
c. AV contractor is to provide the control hardware and connection to all devices that will be controlled.
d. Provide basic control of systems to demonstrate proper connectivity between the control system and controlled devices.
7600 Dublin Blvd., 3rd Floor, Dublin, CA 94568
e. Coordinate with 3rd party control systems programmer for the scheduling of the hardware deployment, the testing of the basic program and connectivity, and the deployment of the final control code, testing, and commissioning.
f. Provide controller.
g. Provide touch panel controllers. Controls shall include, but are not limited to, display on/off, video layout selection, input source selection, program audio volume control, lighting controls and microphone volume control. Users will have presets so that the LED videowall can be divided up into a single image, side-by-side, three across or four video feeds. Any input into the matrix switcher can be sent to any of the preset areas above. The touch panels will mirror each other in appearance and functionality. Add additional ability to mute control room microphone in the touch panel in the control room.
h. Integrate the control system with the lighting control system.
Item Four (4) REVISION: Specification Section 27 41 16 – Replace Section 2.02 B Lecture Hall Building 2400, Room 2420, Category: Video to read as follows:
Description Make Model Qty.
Notes
Category: Video
Direct-view LED display
DigiLED 1.5 mm, 24.6’ W x 7.4’ H
A/S
Direct-view LED display mount
DigiLED Custom A/R
Video-wall processor
RGB Spectrum GO 18 C3DXX10003RR
A/S
Video matrix switch
Crestron DM-MD16X16-CPU3
A/R
HDBaseT Input Card
Crestron DMC-4KZ-C A/R
HDMI Input Card
Crestron DMZ-4KZ-HD A/R
HDBaseT Output Card
Crestron DMC-4KZ-CO-HD
A/R
HDMI Output Card
Crestron DMC-4K-HDO A/R
HDBaseT Receiver
Crestron DM-RMC-4KZ-100-C
A/R
HDBaseT Receiver
Crestron DM-RMC-4K-SCALER-C
A/R
7600 Dublin Blvd., 3rd Floor, Dublin, CA 94568
HDBaseT Transmitter
Crestron DM-TX-4K-100-C-1G-xT
A/S Confirm finish with Owner
HDMI, VGA Transmitter
Crestron DM-TX-4K-302-C
A/S
HDMI cable retractors
Extron 70-1065-04 A/S
VGA + audio cable retractor
Extron 70-1065-11 A/S
DisplayPort cable retractor
Extron 70-1065-43 A/S
Owner-furnished PC
TBD TBD A/R Provide monitor mount to mount all-in-one PC onto lectern. Coordinate with Owner on location of monitor mount.
Document camera
Wolfvision vSolution Cam A/S
Wireless presentation system
Extron ShareLink 250 W US
A/S
Lecture capture system
Extron SMP 351 A/S 400 GB SSD version
Multi-window processor
Hall Research SSW-HD-4 A/S
PTZ cameras Panasonic AW-HE38H A/S Confirm finish with Owner. If camera is ceiling mounted, use with Vaddio 999-82000-000.
Wall mount Panasonic FEC-40WMx A/S Confirm finish with Owner
Instructor tracker
Optex RLS-2020I A/S Mount using Vaddio 535-2000-212
HDMI distribution amplifier
Hall Research SP-HD-2A A/S
AV bridge QSC I/O-USB Bridge
A/S
USB transmitter
Extron USB Extender Plus T
A/S
USB receiver Extron USB Extender Plus R
A/S
7600 Dublin Blvd., 3rd Floor, Dublin, CA 94568
Confidence monitor
NEC E557Q A/S
Confidence monitor wall mount
Chief MTM1U A/R
Item Five (5) REVISION: Specification Section 27 41 16 – Replace Section 2.02 B Lecture Hall Building 2400, Room 2420, Category: Control to read as follows:
Category: Control
Controller Crestron CP3N A/S
Touch panel controller
Crestron TSW-1060-NC A/S Confirm finish with Owner. Integrate qty 1 into lectern.
Touch panel controller tabletop kit
Crestron TSW-1060-TTK-x-S
1 Confirm finish with Owner
3rd Party Control Program
PepperDash Master Quote Reference: TEEC005 – Las Positas College – interactive classroom 2420
A/R Refer to section 1.05 B 4 for contact information
Item Six (6) REVISION: Specification Section 27 41 16 – Replace Section 2.02 B Lecture Hall Building 2400, Room 2420, Category: Accessories to read as follows:
Category: Accessories
Lectern Spectrum Industries
55259CHBTW A/R Wild Cherry / Black metal with insert panel. Include 96507, qty 1.
Table box Extron 60-1405-02 A/S Include Extron 60-1697-01, qty 1. Work with Owner on cable and power layout.
7600 Dublin Blvd., 3rd Floor, Dublin, CA 94568
Network connector module
Extron 70-100-11 A/S Coordinate connection with IT dept.
Lift rental, wallplates, cables, screws, power conditioner, power distribution unit, etc.
A/R
Item Seven (7) REVISION: Specification Section 09 68 00 – Revise Section 1.02 E to read:
E. Submit color sample MOSAIC 28502 for Architect’s review.”
Item Eight (8) REVISION: Specification Section 10 28 00 – Replace in its entirety Section 2.04 A, Item 4 to read as follows:
4. Sanitary Napkin Disposal Unit: Stainless steel, self-closing door, locking
bottom panel with full-length stainless steel piano-type hinge, removable
receptacle.
a. Product: B-354 manufactured by Bobrick, partition mounted.”
Item Nine (9) REVISION: Sheet A-100 - Overall Site and Accessibility Plan: Added arrow for second tow-away sign. Item Ten (10) REVISION: Sheet A-101 – Enlarged Site Plan: Revised notes to repaint stripping at accessible parking. Item Eleven (11) REVISION: Sheet A-131 – Demo and New Toilet Room Floor Plans: Added sanitary napkin disposal unit at women’s toilet partition and patching notes to restrooms.
7600 Dublin Blvd., 3rd Floor, Dublin, CA 94568
Item Twelve (12) REVISION: Sheet A-411 – Details: Revised tow-away sign Detail No. 8 Sign – Tow Away with correct address and phone number. Item Thirteen (13) REVISION: Sheet E-001 – Electrical Title Sheet: Revised Data symbol description under Telephone/Data legend. Item Fourteen (14) REVISION: Sheet E-121 – Enlarged New Power & Data Plan: Revised elevation reference Details from E5.1/1 and E5.1/2 to E-410/1 and E-410/2. B. BID QUESTIONS AND RESPONSES: Item One (1): Comment: Regarding the DigiLED video wall:
a) Will the lighting conditions vary when in use?
b) What will the wall structure be that we are mounting the wall to?
c) Is there a spare component percentage for the video wall?
Response: a) No, the auditorium is a controlled environment. b) See Sheet S-301. c) See Addendum No. 2, Section A, Item Two (2)
Item Two (2): Comment: Is there a quote for the spectrum lectern? Response: Spectrum lectern is found under specification section 27 41 16 in order to provide pricing for this bid. Item Three (3): Comment: Do we submit pricing to the GC’s or to the College? Response: Pre-bid conference sign-in sheet for General Contractor’s contact information can be found using the link below: http://www.clpccd.org/bond/BiddingProjectBusinessOpportunitiesRFB.php
7600 Dublin Blvd., 3rd Floor, Dublin, CA 94568
Item Four (4): Comment: Has the structural engineer addressed the video wall weight? Based on the Video Wall Vendor, the install weight of the total panels will be 1600 pounds. Response: The LED AV wall per Detail 11/S-301 was designed to support total of 120 panels (max. total weight of 1600 lbs.). Note that Sheet S-301 was approved by DSA as part of the Contract Documents. Item Five (5): Comment: Will the contractor be required to have the drawings stamped by a structural engineer? Response: All the structural drawings (S-001, S-141, and S-301) were stamped by ATI Architects + Engineers structural engineer – Robert Riegel and were approved by DSA as part of the Contract Documents. C. ATTACHMENTS: DRAWINGS (6 sheets)
Architectural: A-100 OVERALL SITE AND ACCESSIBILTY PLAN A-101 ENLARGED SITE PLAN A-131 DEMO AND NEW TOILET ROOM FLOOR PLANS A-411 DETAILS
Electrical: E-001 ELECTRICAL TITLE SHEET E-121 ENLARGED NEW POWER & DATA PLAN
All other terms and conditions of Bid No.: B18/19-04 shall remain the same. The failure of any proposer to acknowledge such addenda on its bid proposal form will render proposal non-responsive and rejected. Mare Hampton, Purchasing and Warehouse Services, Manager Chabot-Las Positas Community College District
09/20/199/24/19#2
09/20/199/24/19#2
09/20/199/24/19#2
09/20/199/24/19#2
1E4.1
A
OS
OS
PP
PC
TS
OS
RC
PS
1BE1.1
AC1
1 2
PB
OS
T
J
J
J
JJ
M
VS
AS
R
C
4
GFI
+18"
TL
+18"
S
MAV
V
WP S
FAAP
FATC
FACP
H
H
F
S
S
H
SD
HD
HD
DD
TS
FS
PIV
1
1
,
HEAVY DUTY SWITCH EQUIPED WITH DUMMY FUSE.
(ALL SYMBOLS SHOWN ARE NOTNECESSARILY ON DRAWINGS)
LIGHTING PANEL ANDCIRCUIT/RELAY NUMBER
LEGEND
EQUIPMENT (NIC) ORELECTRICAL EQUIPMENTFURNISHED BY OWNER
FUTURE EQUIPMENT
CONDUIT(REFER TO PLANS FOR ADDITIONAL INFORMATION)
3/4" CONDUIT WITH QUANTITY OF CONDUCTORS AS INDICATED BY HASH MARKS. NUMBER ADJACENTTO HASH MARKS INDICATES WIRE SIZE. HASH MARKS WITHOUT NUMBER INDICATES #12 CONDUCTORS.NO HASH MARKS INDICATES 2 #12 CONDUCTORS. (GROUND CONDUCTOR IS NOT INDICATED. INCLUDEGREEN GROUND SIZED PER NEC 250-122 IN ALL FEEDER AND BRANCH CIRCUIT CONDUITS.)
RECEPTACLE - WALL MOUNTED DUPLEX (NEMA 5-20R UNO) NUMERALINDICATES CIRCUIT NUMBER. +18" AFF U.O.N.
RECEPTACLE - WALL MOUNTED DOUBLE DUPLEX (NEMA 5-20R UNO)NUMERAL INDICATES CIRCUIT NUMBER, +18" AFF.
RECEPTACLE - WALL MOUNTED ISOLATED GROUND DUPLEX (NEMA 5-20R UNO) NUMERALINDICATES CIRCUIT NUMBER. GFI INDICATES GFI RECEPTACLE, +18"AFF.
RECEPTACLE (NEMA 5-204 UNO) - CEILING, FLUSH
RECEPTACLE (NEMA 5-20R UNO) - FLOOR, FLUSH
SPECIAL RECEPTACLE - TWISTLOCK (NEMA L-204 UNO)VOLTS, AMPS, PHASE AS INDICATED
RECEPTACLE - SPECIFIC - NEMA CONFIGURATION INDICATED-FLOOR MOUNTED, FLUSHVOLTS, AMPS, PHASE AS INDICATED
SHEET NOTE TAG
REVISION REFERENCE, REVISION #1SHOWN
GFI
ST
GROUND FAULT INTERRUPTING MODULE OR DEVICE (SINGLELINE)
SHUNT TRIP MODULE OR DEVICE (SINGLELINE)
LIGHTING FIXTURE DESIGNATION
D
PSA
NON-METALLIC COMBINATION FLOOR BOX WITH FLANGED COVER - FLOOR MOUNTED, FLUSH (SLAB ONGRADE) - (2) WIREMOLD #880MP, "A"=PROVIDE (2)#830CKTAL-3/4" COVERS AND #828TCAL FLANGE,"B"=PROVIDE #828 AND #828 GFI TC COVERS AND #827B FLANGE, "C"=PROVIDE SINGLE #880MP WITH#880CKTAL-3/4" COVER
A
A
FURNITURE FEED FLOOR POKE THRU WITH CONDUIT CONNECTIONS - FLOOR MOUNTED, FLUSH - (2)WIREMOLD #4AFFATC BS, "A"=FLEX CONNECTION FOR POWER AND DATA, "B"=FLEX CONNECTION FORPOWER ONLY
POWER - CONTINUED
T DRY TYPE TRANSFORMER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
TRANSFORMER - DELTA PRIMARY - GROUNDED WYE SECONDARY - RATING AS SHOWN
(NON JOB SPECIFIC)
MULTI-OUTLET NON-METALLIC SURFACE RACEWAY, 2-CHANNEL WITH DUPLEXRECEPTACLES AND DUPLEX DATA OUTLETS, MOUNT RACEWAY +18" ABOVE FINISHEDFLOOR OR AS NOTED.
3 1 3 1
DUPLEX RECEPTACLE, ONE SIDE SWITCHED, +18" U.O.N.
NON-FUSED HEAVY DUTY SWITCH, 3 POLE, AMPERE RATING AS SHOWN
SINGLE RECEPTACLE 18" AFF U.O.N.
GFI
TELEPHONE/DATA CONDUIT WITH PULLCORD ONLY
FLEXIBLE CONDUIT
TELEPHONE CONDUIT WITH PULLCORD ONLY
CABLE OR CONDUIT TURNING DOWN
CABLE OR CONDUIT TURNING UP
BRANCH CIRCUIT HOME RUN TO PANELBOARD 2 #12 AWG AND 1 #12 GROUND IN 3/4" EMT CONDUIT,U.O.N. PANEL A - CIRCUIT "13"
T/D
T
A-13
T
S
CONDUIT UNDERGROUND ROUTE FOR "CABLE TV/TELEPHONE"TV/T
WPGFI
DUPLEX RECEPTACLE IN WEATHERPROOF BOX
TWIST LOCK RECEPTACLELIGHTING BRACH CIRCUITS SHALL NOTE BE COMBINED W/ RECEPTACLES OR CONDUITSINTO MULTI-WIRE BRUNCH CIRCUIT UNLESS SO INDICATED ON THE DRAWINGS.
CONDUIT WITH CONDUCTORS OR CABLE EXPOSED ON WALL
CONDUIT WITH CONDUCTORS OR CABLE CONCEALED IN WALL
EXISTING CONDUIT WITH CONDUCTORS OR CABLE EXPOSED ON WALL
CONDUIT STUBBED OUT IN ACCESSIBLE LOCATION AND CAPPED
FIRE ALARM CONDUIT WITH CONDUCTORS OR CABLE EXPOSED ON WALL
EXISTING CONDUIT WITH CONDUCTORS OR CABLE CONCEALED UNDER FLOOR OR GROUND
FIRE ALARM CONDUIT WITH CONDUCTORS OR CABLE CONCEALED UNDER FLOOR ORGROUND
PG&E SECONDARY CONDUIT ONLY (W/NYLON PULL CORD) CONCEALED UNDERFLOOR ORUNDERGROUND.
TELEPHONE CONDUIT ONLY (W/NYLON PULL CORD) CONCEALED UNDERFLOOR OR UNDERGROUND.
CONDUIT WITH CONDUCTORS OR CABLE CONCEALED UNDER FLOOR OR GROUND
EXISTING CONDUIT WITH CONDUCTORS OR CABLE CONCEALED IN WALL
;
FA
FA
COMBINATION STARTER AND CIRCUIT BREAKER.
COMBINATION FUSED DISCONNECT AND MAGNETIC STARTER.
TWO CHANNEL RACEWAY WIREMOLD 5400WM
LA-1,3,5
#10
HOMERUN TO PANEL LA, CIRCUITS #1,3,5 & LONG HASH MARK INDICATE NUETRAL, "HOOK" INDICATESGND. W/O LONG HASH MARK INDICATES SHARED NEUTRAL. 3/4" CONDUIT UON
EXISTING CONDUIT WITH CONDUCTORS OR CABLE CONCEALED IN CEILING OR PLENUMCONDUIT WITH CONDUCTORS OR CABLE CONCEALED IN CEILING OR PLENUM
PANELBOARD, OR STC RECESSED.
CEILING MOUNT OCCUPANCY SENSOR
MAIN OR DISTRIBUTION SWITCHBOARD
DC-AC INVERTER
DISCONNECT SWITCH - NON-FUSED 30 AMP, 3P UNO
DISCONNECT SWITCH - FUSED 30 AMP, 3P UNO, AT - AMPERE TRIP,AF - AMPERE FRAME, P - NUMBER OF POLES
COMBINATION MAGNETIC MOTOR STARTER WITH OVERLOADS
XX A
XX ATXX AFF
T TRANSFORMER - FLOOR MOUNTED - KVA INDICATED
MANUAL MOTOR STARTER WITH OVERLOADS - o=PILOT LIGHT. HORSEPOWERRATING AND OVERLOAD SIZED FOR MOTOR CONTROLLED
T C TIMECLOCK AND CONTACTOR PANEL
BRANCH PANEL - FLOOR MOUNTED, FLUSH
BRANCH PANEL - WALL MOUNTED, SURFACE
JUNCTION BOX - CEILING MOUNTED, SURFACE
JUNCTION BOX - WALL MOUNTED, FLUSH - WP=WEATHER PROOF
JUNCTION BOX - FLOOR MOUNTED, FLUSH
PULL BOX - FLUSH OR SURFACE MOUNTED - SIZE PER CEC
MD MOTORIZED DAMPER - PROVIDED BY DIVISION 23 (PROVIDE SPST DISCONNECT SWITCH)
WP
MOTOR OUTLET WITH FLEX CONNECTION
METERS AND INSTRUMENTS, LETTER(S) DESIGNATE TYPE
PANELBOARD, SURFACE MTD.
MAIN OR DISTRIBUTION SWITCHBOARD
PANELBOARD, RECESSED.
CONTACTOR IN NEMA 1 ENCLOSURE, SIZE AND RATING AS INDICATED
RELAY IN NEMA 1 ENCLOSURE, SIZE AND RATING AS INDICATED
JUNCTION BOX, SURFACE MOUNTED, WALL MOUNTED, WEATHERPROOF
TERMINAL CABINET AS NOTED
VOLTMETER SELECTOR SWITCH
AMMETER SELECTOR SWITCH
GROUND FAULT PROTECTIONGFP
CIRCUIT BREAKER, RATINGS AS INDICATED
M
COPPER CLAD GROUND ROD - 3/4" DIA. x 10'-0" LONG
CONNECTION TO GROUND
;
ELECTRICAL SYMBOLS:
MAIN TELEPHONE BACKBOARD.
DISCONNECT SWITCH - FUSED 30 AMP, 3P UNO, AT - AMPERE TRIP,AF - AMPERE FRAME, P - NUMBER OF POLES
+18"
DUPLEX RECEPTACLE, MTD ABOVE COUNTER TOP - HORIZONTALLY MOUNTED.GFI INDICATES GFI RECEPTACLE.
+18"
IN SLAB RACEWAY - IN FLOOR MOUNTING
POWER
TELEPHONE / DATA
COMBINATION DATA/TELEPHONE OUTLET - FLUSH MOUNTED
DATA OUTLET LOCATION
COMBO PROJECTOR/TEACHER OUTLET BOX FLUSH MOUNTED EITHERIN CEILING OR WALL - "C"=FLUSH CEILING MOUNTED
CALL BUTTON
FUTURE CAMERA
C VIDEO CONTROL PANEL
1-GANG OUTLET W/10K POT VOLUME CONTROL FOR AUDIO/VISUAL
SPEAKER OUTLET - CEILING MOUNTED, FLUSH
WEATHER PROOF EXTERIOR SPEAKER
MULTI-USE SPEAKER
MICROPHONE OUTLET - WALL MOUNTED, FLUSHED
CLOCK OUTLET, WALL MOUNTED-FLUSH
SPEAKER OUTLET, WALL MOUNTED-FLUSH
TV/CABLE OUTLET, WALL MOUNTED-FLUSH
MICROPHONE OUTLET, FLOOR MOUNTED-FLUSH
TELEPHONE OUTLET, FLUSH MOUNTED
DEDICATED FOR FAXWALL MOUNTEDPUBLIC TELEPHONEP
FW
A/V CONTROL STATION WITH A/V INPUT OUTLET BELOW
PROJECT A/V OUTLET
USB SMARTBOX OUTLET
B
EXTERIOR FA HORN AT +90" MIN. AFF TO THE TOP OF DEVICE.WP=WEATHERPROOF.
FIRE ALARM HORN/STROBE AT 80" AFF MIN. AND 96" MAX TO THE BOTTOM OF DEVICE.75=75 CANDELA
INTERIOR FA HORN AT +90" MIN. AFF TO THE TOP OF DEVICE, NOT LESS THAN 6" BELOW CEILING.WP=WEATHERPROOF.
EOL
D
15
15
WP
SUPERVISED VALVE TAMPER SWITCH
WATER FLOW ALARM SWITCH
15=15 CANDELAFIRE ALARM STROBE AT 80" AFF MIN AND 96" MAX TO THE BOTTOM OF DEVICE.
FA MANUAL PULL STATION AT 48" AFF TO CENTER LINE.
SMOKE DETECTOR, IONIZATION TYPE, CEILING TYPE
FIRE ALARM HEAT DETECTOR CEILING MOUNTED.
FIRE ALARM HEAT DETECTOR INSTALLED IN ATTIC SPACE.
HVAC DUCT MOUNTED SMOKE DETECTOR
END OF LINE RESISTOR.
FIRE ALARM ANNUNICATOR PANEL.
FIRE ALARM CONTROL PANEL.
FIRE ALARM TERMINAL CABINET.
POST INDICATING VALVE.
;
FIRE ALARM
PARKING LOT LIGHTING, TWIN HEAD
EXISTING EMERGENCY FIXTURE WITH BATTERY BACKUP
RECESSED MOUNTED FIXTURE
RECESSED MOUNTED FIXTURE W/ EMERGENCY BATTERY BACKUP BALLAST
SURFACE OR PENDANT MOUNTED FIXTURE
PENDANT MOUNTED FIXTURE. LETTER DENOTES SWITCH, NUMBER DENOTES CKTNUMBER. SOLID AREA INDICATES EMERGENCY BATTERY BACK
a 2
INTERIOR/EXTERIOR WALL MOUNTED LIGHT FIXTURE. SOLID INDICATES LIGHT FIXTURE W/EMERGENCY BATTERY BACKUP.
;ILLUMINATED EXIT SIGN AND JUNCTION BOX, CEILING OR WALL MOUNTED, DARK AREAINDICATES FACE(S) ON SIGN, ARROW(S) INDICATE DIRECTION TO EXIT
TRACK FOR TRACK LIGHTING
TRACK FIXTURE
PARKING LOT LIGHTING. POLE MOUNTED. ONE OR TWO HEAD
ALL SWITCHES SPST, 120/277V, 20A UON, SUBSCRIPTS AS NOTED:a OUTLET SWITCHED3 THREE WAYK KEYEDOS OCCUPANCY SENSOR EQUIPPEDD DIMMER SWITCHT SINGLE POLE MOTOR RATED SWITCH
WITH THERMAL OVERLOAD ELEMENT
2 DOUBLE POLE4 FOUR WAYLV LOW VOLTAGES SENTRY SWITCHP WITH PILOT LIGHTR RELOCATED
STAGE/ACCENT LIGHTING FIXTURE
LIGHT FIXTURE FURNISHED WITH EMERGENCY POWER PACKTO BE CONNECTED TO UNSWITCHED LEG OF LIGHTING CIRCUIT
;
TRACK LIGHT
SURFACE/RECESSED MOUNTED COMPACT FIXTURE WITH JUNCTION BOX. NUMBER DENOTESCIRCUIT NUMBER, LOWER LETTER DENOTES CONTROLLING DEVICE. SOLID INDICATES LIGHTFIXTURE W/ EMERGENCY BATTERY BACKUP.
SUSPENDED AIRCRAFT CABLE MOUNTED LIGHTING TRACK WITH JUNCTION BOX. EACH TRACKREPRESENTS AND ATTACHED TRACK LIGHTING FIXTURE. NUMBER DENOTES CIRCUIT NUMBER.LOWER LETTER DENOTES CONTROL DEVICE.
PENDANT MOUNTED FIXTURE WITH JUNCTION BOX. NUMBER DENOTES CIRCUIT NUMBER, LOWERLETTER DENOTES CONTROL DEVICE.
STRIP OR INDUSTRIAL FIXTURE WITH JUNCTION BOX. MOUNTED AS INDICATED IN LIGHTINGFIXTURE SCHEDULE. NUMBER DENOTES CIRCUIT NUMBER.
LONG WALL MOUNTED FIXTURE, WITH JUNCTION BOX ON 24 HOUR CIRCUIT. NUMBER DENOTESCIRCUIT NUMBER, LOWER LETTER DENOTES CONTROLLING DEVICE. NL=NIGHTLIGHT.
LONG WALL MOUNTED FIXTURE, WITH JUNCTION BOX. NUMBER DENOTES CIRCUIT NUMBER,LOWER LETTER DENOTES CONTROLLING DEVICE.
3a
4a
2a
49
NL
2a
1A-7
BOLLARD LIGHT.
"EXIT" SIGN AND EMERGENCY LIGHT FIXTURE."1A-7" DENOTES POWER AT PANEL 1A, CKT.#7.
EMERGENCY LIGHT(S) WALL FIXTURE WITH BATTERY AND CHARGER
RECESSED FIXTURE WITH OUTLET AND JUNCTION BOX, LOWER CASE LETTER DENOTESCONTROLLING DEVICE, NUMBER DENOTES CIRCUIT NUMBER, SOLID DOT DENOTES EMERGENCY,1/2 DOT DENOTES 1/2 OF FIXTURE ON EMERGENCY
RECESSED FIXTURE PREWIRED WITH MANUFACTURED INTERCONNECTING CABLE(M = MASTER, S = SATELLITE, I = INDIVIDUAL)(NOTES AS ABOVE)
;
;
;
;
;
;
;
;
;
;
LIGHTING
;
HID, FIXTURE, WALL SURFACE OR RECESSED MOUNTED WITH JUNCTION BOX (REFER TO LIGHTINGFIXTURE SCHEDULE FOR MOUNTING TYPE).
;
XX ATXX AF
XX ATXX AF
LIGHTING - CONTINUED
OCCUPANCY SENSOR SWITCH - WALL MOUNTED - LOWER CASE LETTER DENOTES CONTROL
INFA-RED OCCUPANCY SENSOR AND POWER PACK - CEILING MOUNTED
DIMMER SWITCH WITH OVERRIDE - WALL MOUNTED - SLIDE TYPE
PHOTO SENSOR
METALLIC COMBINATION FLOOR BOX WITH 2-GANG COVER PLATE - FLOOR MOUNTED FLUSH - (2)WIREMOLD #880S2 WITH #827B FLANGE "A"=PROVIDE (2) #828R AND #828 GFI TC COVERS (SSCPTABLES) "B"=PROVIDE #828 SPTC AND #829 STC COVERS (ATM AND PHONE)
RECESSED LARGE CAPACITY FLOOR BOX WITH BRASS COVER - FLOOR MOUNTED, FLUSH - (2)WIREMOLD #RFB9 WITH #RFB119 BTCAL COVER (SSCP)
CEILING MOUNTING POWER PACK
PHOTO CELL ASSEMBLY, MOUNT ON ROOF, WITH FLASHED ON ROOF JACK, (U.O.N.) AIM TOWARDSNORTH
TIME SWITCH, MOUNTED IN ENCLOSURE, FLUSH IN WALL
OCCUPANCY SENSOR AND POWER PACK - CEILING MOUNTED
ROOM CONTROL
a
CALLOUTSEQUIPMENT TYPE,SEE ABBREVIATIONS
EQUIPMENT NO.
[HA-1]
FLOOR PLAN/DETAIL NO.
SHEET NO.
SECTION DETAIL NO.
REFERENCE SHEET NO.
WORKING SPACE CLEARANCE
ELECTRICAL EQUIPMENT
CONDUIT TAG, SEE ''CONDUIT SCHEDULE'' FOR CONDUIT REQUIREMENTS"E" = ELECTRICAL, "D" = DATA AND SIGNAL
REFERENCE POINT
(ALL SYMBOLS SHOWN ARE NOTNECESSARILY ON DRAWINGS)
E-001
ELECTRICALTITLE SHEET
DS WL
A R C H I T E C T S+
E N G I N E E R S
09/24
/2019
- 02
:38:52
PM
P:\C
\C95
00 C
habo
t-Las
Pos
itas_
CC\C
9507
_LPC
_AV_
Wall
\3_Dw
gs\E
-001
\+E-
001-
INDE
X.dw
g -
dsno
w
LAS POSITAS COLLEGE
B2420 AV WALLREPLACEMENT
3000 CAMPUS HILL DRIVELIVERMORE, CA 94551-7650
C950708/21/2019
LI C
E
N S E D A R C HI T
EC
T
ST
AT
E O F C A L I F O
RN
I A
LU
K E SHIRA S
C-31985
RENEWALDATE
NOV. 2019
PROJECT NO:
CHECKED BY:
DATE:
SHEET NO:
PROFESSIONAL STAMP:
KEY PLAN:
ITEM: REVISION / ISSUE: DATE:
CONSULTANT:
THIS
DOC
UMEN
T, A
ND T
HE IN
FORM
ATIO
N CO
NTAI
NED
HERE
IN, A
RE T
HE S
OLE
PROP
ERTY
OF
ATI A
RCHI
TECT
S +
ENGI
NEER
S. A
NY U
SE O
R MO
DIFI
CATI
ONS
OF T
HIS
DOCU
MENT
, IN W
HOLE
OR
IN P
ART,
WIT
HOUT
THE
WRI
TTEN
PER
MISS
ION
OF A
TI A
RCHI
TECT
S +
ENGI
NEER
S, IS
STR
ICTL
Y PR
OHIB
ITED
.
DSA:
3050 Pullman Street Costa Mesa, CA 92626 - T 714.338.1600
3009 Douglas Blvd #290 Roseville, CA 95661 - T 916.772.1800
4750 Willow Road #250 Pleasanton, CA 94588 - T 925.648.8800
DRAWN BY:
ADDENDUM #1 09/24/191
1. SEE AV DRAWINGS FOR ADDITIONAL INFORMATION
#2
E-4101
E-4102
7D 9D 11D 13D 15D 17D 19D 21D
23
Panel PE Data JB
A R C H I T E C T S+
E N G I N E E R S
09/24
/2019
- 02
:42:09
PM
P:\C
\C95
00 C
habo
t-Las
Pos
itas_
CC\C
9507
_LPC
_AV_
Wall
\3_Dw
gs\E
-121
\+E1
21-E
nlg.dw
g -
dsno
w
LAS POSITAS COLLEGE
B2420 AV WALLREPLACEMENT
3000 CAMPUS HILL DRIVELIVERMORE, CA 94551-7650
C950708/21/2019
LI C
E
N S E D A R C HI T
EC
T
ST
AT
E O F C A L I F O
RN
I A
LUK E SHIRA S
C-31985
RENEWALDATE
NOV. 2019
PROJECT NO:
CHECKED BY:
DATE:
SHEET NO:
PROFESSIONAL STAMP:
KEY PLAN:
ITEM: REVISION / ISSUE: DATE:
CONSULTANT:
THIS
DOC
UMEN
T, A
ND T
HE IN
FORM
ATIO
N CO
NTAI
NED
HERE
IN, A
RE T
HE S
OLE
PROP
ERTY
OF
ATI A
RCHI
TECT
S +
ENGI
NEER
S. A
NY U
SE O
R MO
DIFI
CATI
ONS
OF T
HIS
DOCU
MENT
, IN W
HOLE
OR
IN P
ART,
WIT
HOUT
THE
WRI
TTEN
PER
MISS
ION
OF A
TI A
RCHI
TECT
S +
ENGI
NEER
S, IS
STR
ICTL
Y PR
OHIB
ITED
.
DSA:
3050 Pullman Street Costa Mesa, CA 92626 - T 714.338.1600
3009 Douglas Blvd #290 Roseville, CA 95661 - T 916.772.1800
4750 Willow Road #250 Pleasanton, CA 94588 - T 925.648.8800
DRAWN BY:
ADDENDUM #1 09/24/191
1 ENLARGED NEW FLOOR PLAN SCALE : 1/4" = 1'-0"
E-121
ENLARGEDNEW POWER& DATA PLAN
1#2