addendum: no. 1 · test report(s) by independent testing agency itemizing compliance and acceptable...

22
Page 1 of 2 1400 Corporate Center Curve, Suite 100 Eagan, Minnesota 55121 Addendum: No. 1 Project No: 19-01 Date: February 7, 2019 Project: VILLAGE COOPERATIVE OF LOVELAND Located in Loveland, Colorado TO: Contractors and all others to whom the Project Manual and the Project Drawings have been issued by the Architect. This Addendum forms a part of the Contract Documents and modifies the Project Manual and the Construction Document Drawings dated January 7, 2019 and all addenda issued to date. CHANGES TO THE PROJECT MANUAL (specifications) Section 00-4323 – Alternates Form Revise section to add Alternate #3: In-lieu of metal wrapped fascia and soffits, provide cement board facia and cement board vented/non-vented soffits. (highlighted in yellow) Section 08-5313 – Vinyl Windows and Patio Doors Section 2.01 A.1; Revise Prime Windows contact information (highlighted in yellow) Section 08-7100 – Door Hardware Add section to Project Manual Section 10-1400 – Signage Add detail pages 10-1400-4 and 10-1400-5 to end of section.

Upload: others

Post on 25-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

Page 1 of 2  

 1400 Corporate Center Curve, Suite 100

Eagan, Minnesota 55121

Addendum: No. 1 Project No: 19-01 Date: February 7, 2019

Project: VILLAGE COOPERATIVE OF LOVELAND

Located in Loveland, Colorado

TO: Contractors and all others to whom the Project Manual and the Project Drawings have been issued by the Architect.

This Addendum forms a part of the Contract Documents and modifies the Project Manual and the Construction Document Drawings dated January 7, 2019 and all addenda issued to date.

CHANGES TO THE PROJECT MANUAL (specifications) Section 00-4323 – Alternates Form Revise section to add Alternate #3: In-lieu of metal wrapped fascia and soffits,

provide cement board facia and cement board vented/non-vented soffits. (highlighted in yellow)

Section 08-5313 – Vinyl Windows and Patio Doors Section 2.01 A.1; Revise Prime Windows contact information (highlighted in

yellow) Section 08-7100 – Door Hardware Add section to Project Manual

Section 10-1400 – Signage Add detail pages 10-1400-4 and 10-1400-5 to end of section.

Page 2: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

Page 2 of 2  

CHANGES TO STRUCTURAL DRAWINGS

See attached Structural Addendum 1 cover letter dated February 7, 2019 from Larson Engineering.

CHANGES TO ELECTRICAL DRAWINGS

See attached Electrical Addendum 1 cover letter dated February 7, 2019 from Steen Engineering.

END OF ADDENDUM 1

Page 3: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

19-01 / Village Cooperative ofLoveland

00-4323 - 1 ALTERNATES FORM

SECTION 00-4323ALTERNATES FORM

PARTICULARS1.01 THE FOLLOWING IS THE LIST OF ALTERNATES REFERENCED IN THE BID SUBMITTED BY:1.02 (BIDDER) _______________________________1.03 TO (OWNER ): VILLAGE COOPERATIVE OF LOVELAND1.04 DATED ________________ AND WHICH IS AN INTEGRAL PART OF THE BID FORM.ALTERNATES LIST2.01 THE FOLLOWING AMOUNTS SHALL BE ADDED TO OR DEDUCTED FROM THE BID AMOUNT. REFER

TO SECTION 01-2300 - ALTERNATES.

ALTERNATE #1 : GRANITE COUNTER TOPS IN COMMONS AREA KITCHEN AND CLUN ROOM IN LIEU OF PLAMADD / DEDUCT: $ _______________

ALTERNATE #2: FIRE PUMP FOR SPRINKLER SYSTEM INCLUDING ALL MECHANICAL HOOK-UPSADD / DEDUCT: $________________

ALTERNATE #3: IN LIEU OF METAL WRAPPED FASCIA AND SOFFITS, PROVIDE CEMENT BOARD FASCIA AND CEMENT BOARD VENTED / NON VENTED SOFFITSADD / DEDUCT: $________________

END OF SECTION

jbredeson
Highlight
Page 4: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

19-01 / Village Cooperative ofLoveland

08-5313 - 1 VINYL WINDOWS AND PATIODOORS

SECTION 08-5313VINYL WINDOWS AND PATIO DOORS

PART 1 GENERAL1.01 SECTION INCLUDES

A. Vinyl-framed, factory-glazed windows and Patio Doors.B. Operating hardware.C. Insect screens.

1.02 RELATED REQUIREMENTS1.03 REFERENCE STANDARDS

A. AAMA/WDMA/CSA 101/I.S.2/A440 - North American Fenestration Standard/Specification for windows,doors, and skylights; 2011.

B. AAMA 701/702 - Combined Voluntary Specifications for Pile Weatherstrip and Replaceable FenestrationWeatherseals; 2011.

C. AAMA 1503 - Voluntary Test Method for Thermal Transmittance and Condensation Resistance ofWindows, Doors and Glazed Wall Sections; 2009.

D. ASTM E1996 - Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, andImpact Protective Systems Impacted by Windborne Debris in Hurricanes; 2014.

E. ASTM E2112 - Standard Practice for Installation of Exterior Windows, Doors and Skylights; 2007.1.04 ADMINISTRATIVE REQUIREMENTS

A. Preinstallation Meeting: Convene one week week before starting work of this section.1.05 SUBMITTALS

A. See Section 01-3000 - Administrative Requirements, for submittal procedures.B. Shop Drawings: Indicate opening dimensions, framed opening tolerances, affected related work, and

installation requirements.C. Grade Substantiation: Prior to submitting shop drawings or starting fabrication, submit one of the following

showing compliance with specified grade:1. Evidence of AAMA Certification.2. Evidence of WDMA Certification.3. Evidence of CSA Certification.4. Test report(s) by independent testing agency itemizing compliance and acceptable to authorities

having jurisdiction.1.06 QUALITY ASSURANCE

A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section, withnot less than three years of documented experience.

B. Installer Qualifications: Company specializing in performing of type specified and with at least three yearsdocumented experience.

1.07 DELIVERY, STORAGE, AND HANDLINGA. Protect finished surfaces with wrapping. Do not use adhesive papers or sprayed coatings that bond when

exposed to sunlight or weather.1.08 FIELD CONDITIONS

A. Maintain this minimum temperature during and after installation of sealants.1.09 WARRANTY

A. See Section 01-7800 - Closeout Submittals, for additional warranty requirements.PART 2 PRODUCTS2.01 MANUFACTURERS - (ONLY SUBSTITUTIONS APPROVED PRIOR TO BIDDING WILL BE REVIEWED ANY

SUBSTITUTION AFTER THE BID WILL BE REJECTED.)A. Vinyl Windows & Patio Doors:

1. Prime Windows; Call Andrew Bingham w/ Timber Ridge for preferred pricing, (719) 661-47152. Thermo-Tech; Call Craig Gerkin w/ MW&D for preferred pricing, (612) 910-49943. Pella Corporation; 350 Series: www.pellacommercial.com/#sle.

jbredeson
Highlight
Page 5: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

19-01 / Village Cooperative ofLoveland

08-5313 - 2 VINYL WINDOWS AND PATIODOORS

4. Substitutions: See Section 01-6000 - Product Requirements.2.02 VINYL WINDOWS & PATIO DOORS

A. Vinyl : Factory fabricated frame and sash members of extruded, hollow, ultra-violet-resistant, polyvinylchloride (PVC) with integral color; with factory-installed glazing, hardware, related flashings, anchorage andattachment devices.1. Configuration: As indicated on drawings.2. Color: Standard Manufactures Colors.3. Size to fit openings with minimum clearance around perimeter of assembly providing necessary space

for perimeter seals.4. Operable Units: Double weatherstripped.5. Framing Members: Fusion welded corners and joints, with internal reinforcement where required for

structural rigidity; concealed fasteners.6. System Internal Drainage: Drain to exterior side by means of weep drainage network any water

entering joints, condensation within glazing channel, or other migrating moisture within system.7. Glazing Stops, Trim, Flashings, and Accessory Pieces: Formed of rigid PVC, fitting tightly into frame

assembly.8. Mounting Flange: Integral to frame assembly, providing weather stop at entire perimeter of frame.9. Insect Screens: Tight fitting for operating sash location.10. Extension Jams: (all 4 sides) Provide jamb extensions up to and including 7-5/8” (194mm) overall

jamb depth and 1/2" thick, shipped loose. Jamb extensions vinyl same color as windows and/or patiodoors. Painted wood jamb extensions are also acceptable. Coordinate with window supplier.

B. Performance Requirements: Provide products that comply with the following:1. Grade: AAMA/WDMA/CSA 101/I.S.2/A440 requirements for specific window type:

a. Performance Class (PC): R.2. Safety glass required where shown on drawings. (Windows in stair towers.)

2.03 COMPONENTSA. Glazing: Insulated double pane, annealed glass, clear, low-E coated, argon filled, with glass thicknesses as

recommended by manufacturer for specified wind conditions and acoustic rating indicated.B. Insect Screens: Aluminum, extruded or roll-formed frame with mitered and reinforced corners; apply

screen mesh taut to frame; secure to window with hardware to allow easy removal.1. Hardware: Manufacturer's standard; quantity as required per screen.2. Screen Mesh: Vinyl-coated fiberglass, window manufacturer's high-transparency mesh.3. Frame Finish: Manufacturer's standard, color to match window frame and sash color.

C. Operable Sash Weatherstripping: Manufactures Standard; permanently resilient, profiled to maintainweather seal in accordance with AAMA 701/702.

2.04 HARDWAREA. Horizontal Sliding Sash: Rigid PVC interfacing tracks with dual brass wheel and stainless steel axle

assembly housing, provide two sets for each operating sash and opening stops in head and sill track asrequired.

B. Vertical Sliding Sash: Metal and nylon spiral friction slide cylinder, provide two for each sash and jamb.C. Sash lock: Lever handle and keeper with cam lock, provide at least one for each operating sash.D. Patio Door Slide Lock: Slide-Co a division of Pime-Line Products #172839 "Sliding Windo Lock" White or

manufacturers approved equal.E. Window Sash Limitors: Provide and install in accordance with local jurisdictional requirements, if applicable.F. Finish of Exposed Hardware: Baked enamel, match interior sash and frame color.

PART 3 EXECUTION3.01 EXAMINATION

A. Verify wall openings and adjoining air and vapor seal materials are ready to receive this work.3.02 INSTALLATION

A. Install window unit assemblies in accordance with manufacturers instructions and applicable buildingcodes.

B. Attach window frame and shims to perimeter opening to accommodate construction tolerances and otherirregularities as necessary.

Page 6: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

19-01 / Village Cooperative ofLoveland

08-5313 - 3 VINYL WINDOWS AND PATIODOORS

C. Align window plumb and level, free of warp or twist, and maintain dimensional tolerances and alignmentwith adjacent work.

D. Install operating hardware.3.03 TOLERANCES

A. Maximum Variation from Level or Plumb: 0.06 inches every 3 ft non-cumulative or 0.5 inches per 100 ft,whichever is less.

3.04 ADJUSTINGA. Adjust hardware for smooth operation and secure weathertight closure.

3.05 CLEANINGA. Remove protective material from pre-finished surfaces.B. Wash surfaces by method recommended and acceptable to window manufacturer; rinse and wipe surfaces

clean.C. Remove excess glazing sealant by moderate use of mineral spirits or other solvent acceptable to sealant

manufacturer and appropriate for application indicated.END OF SECTION

Page 7: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

Section 08 71 00 Door Hardware

PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish all finish hardware specified herein, shown on the door schedule, or required by the drawings. B. Where items of hardware are not definitely or correctly specified and is required for the intended service, such omission, error, or other discrepancy should be directed to the Architect prior to the bid date for clarification by addendum. Otherwise furnish such items in the type and quantity established by this specification for the appropriate service intended. 1.02 RELATED WORK A. Section 06 20 00 - Finish Carpentry. B. Section 08 10 00 - Metal Doors and Frames. C. Section 08 20 00 - Wood Doors: Any intumescent material that may be required to comply with positive pressure fire door testing (test procedure UL10C) to be supplied by the wood door supplier. D. Section 08 40 00 – Aluminum Entrances and Storefronts: All hardware, except hinges, weatherstrip, thresholds, and sweeps to be supplied by 08 71 00. Hinges, weatherstrip, thresholds, and sweeps to be supplied by the aluminum door and frame supplier. Aluminum door and frame supplier shall supply hinges that meet the requirements of this section. Aluminum door and frame supplier shall supply aluminum door and frame manufacturers standard weatherstrip, thresholds, and sweeps. E. Division 26 00 00 – Electrical/Low Voltage, Electronic Access Control: If a piece of electrified door hardware specified requires a proprietary power supply, that power supply is to be supplied by the door hardware supplier regardless if it is called out in the hardware group or not. For all other electrified hardware, regulated filtered power is to be supplied by electrical/access control supplier. Door monitoring to be provided as needed by the electrical/access control supplier. Request- to-exit devices to be provided as needed by the electrical/access control supplier. The electrical/access control supplier is responsible for contacting the hardware supplier to have those request-to-exit switches built into the hardware if that is what they feel is needed, and how they choose to procure them. 1.03 REFERENCES A. A.D.A. - Americans with Disabilities Act. B. ANSI A117.1 - Accessible and Usable Buildings and Facilities. C. NFPA 80 - Standards For Fire Doors and Windows. D. NFPA 101 - Life Safety Code E. U.L. - Building Material Directory. F. D.H.I. - Recommended Locations for Architectural Hardware G. Applicable State and Local Building Codes, including 2006 IBC or latest locally adopted version. 1.04 SUBMITTALS A. Hardware Schedule: Immediately after award of hardware contract, submit five (5) copies of a detailed hardware schedule, vertical format. Prepare under the supervision of an AHC, registered Architectural Hardware Consultant, and under provisions of Division One. 1. Itemize Hardware in the sequence and format established by this specification. 2. List and describe each opening separately. Include all doors with identical hardware, except hand, in a single heading. Include door number, room designations, degree of swing, and hand. 3. List related details. Include dimensions, door and frame material, and other considerations affecting hardware. 4. List all hardware items to be supplied. Include manufacturer's name, quantity, product name, catalog number, size, finish, and related details needed to specifically identify what is being supplied. 5. Attach copies of catalog information for each item that include graphics to help visually identify each item. 6. For each opening with electrical hardware: Prepare and include a riser diagram showing each electrical item supplied by this section in its rough location in relation to the door, all conductor requirements, and the type of back box (if needed) to be supplied by electrical. Each riser diagram should include a detailed written description of the operation of the opening. 7. Resubmit (5) copies of the corrected schedule when required. B. Keying Schedule: After receipt of approved hardware schedule submit a copy of keying schedule as a result of a keying meeting between the owner, and the hardware supplier. C. Samples: If so directed by the Architect, submit samples of finish hardware items for approval. Properly identify each sample as to make and number, and furnish in the specified finish.

Page 8: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

D. Templates: Furnish a copy of approved hardware schedule, along with applicable templates for factory-prepared hardware to each door and frame fabricator. E. Substitutions: Submit under provisions of Division One. Provide detailed information and catalog cuts indicating the comparison to the specified hardware. If requested by the Architect, provide a sample accompanied by a sample of the specified item for comparison. 1.05 QUALITY ASSURANCE A. Qualifications: 1. Manufacturer: Except where specified in the hardware schedule, furnish products of only one manufacturer for each type of hardware. 2. Supplier: A company experienced in the architectural hardware industry for a minimum of two (2) years, and can call upon an AHC, registered Architectural Hardware Consultant, for consultation during the full extent of the project. B. Regulatory Requirements: 1. Furnish UL or Warnock Hersey listed hardware for all fire labeled and 20 minute openings in conformance with requirements for class of opening scheduled, whether specifically called for in this specification or not. 2. Furnish hardware that conforms to all applicable state and local building codes, including IBC positive pressure testing requirements. Where specified hardware is not in conformance with applicable codes, such omission or error should be directed to the Architect prior to the bid date for clarification by addendum, otherwise furnish hardware as required by code. 1.06 DELIVERY, STORAGE AND HANDLING A. Deliver, store and handle in accordance with Division One. Mark each original container with a door number that corresponds to the approved hardware schedule for the installation location. B. Receive, inventory and store hardware in a secure and dry environment, protect against loss and damage. C. Report any shortages to the hardware supplier no later than 48 hours after receipt of delivery to the job site. D. Stockpile items sufficiently in advance to ensure their availability. Coordinate delivery , handling, and installation of hardware items to ensure orderly progress of total work, and minimize or eliminate losses and damage. PART 2 PRODUCTS 2.01 ACCEPTABLE MANUFACTURERS Products Specified Acceptable A. Hinges PBB Stanley, Hager, McKinney, Bommer, Ives B. Flush Bolts D.C.I. Trimco, Ives, Rockwood, Hager C. Locks and Latches Dorma Schlage, PDQ, Yale D. Exit Devices Dorma VonDuprin, PDQ, Yale E. Pulls, Pushbars, Push/Pull Plates Don-Jo Hiawatha, Burns, Rockwood, Hager, Trimco F. Door Closers Dorma LCN, PDQ, Norton, Yale G. Protective Plates Don-Jo Hiawatha, Burns, Rockwood, Hager H. Overhead Stops Dorma Glynn-Johnson, Rixson, Sargent I. Wall Stops, Floor Stops Trimco D.C.I., Hager, Ives J. Electromagnetic Door Holders Dorma Rixson, LCN K. Thresholds, Sweeps, Weatherstrip, Gasket, and Drip Caps National Guard Products Pemko, Reese Other products: If a product is specified in the hardware schedule but not addressed in this part of the specification, then the product supplied can be that of the specified manufacturer or that of another manufacturer as long as the product can be shown to be equal in grade and function for the purpose it was intended. If this occurs, make a note of it on the hardware schedule submitted for approval. 2.02 HINGES A. Acceptable manufacturers and respective catalog numbers: Description P.B.B. Hager Stanley McKinney Bommer Ives Std. Wt. P. B. - Steel PB81 1279 F179 T2714 5000 5PB1 Std. Wt. B. B. - Steel BB81 BB1279 FBB179 TB2714 BB5000 5BB1 Std. Wt. B. B. - Non Ferrous BB21/51 BB1191 FBB191 TB2314 BB5001/2 5BB1 Hvy. Wt. 4 B. B. - Steel 4B81 BB1168 FBB168 T4B3786 BB5004 5BB1HW Hvy. Wt. 4 B. B. - Non Ferrous 4B21/51 BB1199 FBB199 T4B3386 BB5005/6 5BB1HW Std. Wt. Spring Hinge SP81 1250 2060 1502 4310 3SP1

Page 9: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

B. Hinges supplied must be tested and comply with ANSI/BHMA standards for consistency, wear and corrosion resistance. C. Quantity: Furnish hinges for each door leaf as follows, unless otherwise noted in groups: 1. Doors up to and including 90" high - 3 hinges 2. Doors over 90" high through 120" high - 4 hinges 3. Provide one additional hinge for every additional 30" in height over 120" 4. Dutch doors - 4 hinges D. Type: Furnish as follows, unless otherwise noted in groups: 1. Standard weight, plain bearing hinge (PB81) for interior openings through 36" wide without a door closer. 2. Standard weight, ball bearing hinge (BB81) for interior openings over 36" through 40" wide without a door closer, and for interior openings through 40" wide with a door closer. 3. Heavy weight, four ball bearing hinge (4B81) for all interior openings over 40" wide, and for all vestibule doors. 4. Heavy weight , four ball bearing, stainless steel (4B51) or brass (4B21) as required, for all exterior openings. E. Size: Furnish as follows, unless otherwise noted in groups: 1. 1 3/4" doors : 4-1/2" x 4-1/2" 2. Provide proper hinge width to clear trim and allow full 180 degree swing. F. Hinges for all lockable doors opening outward shall have non-removable pin (NRP). All other hinges shall have non- rising pins. G. Provide all hinges with flat button tips unless otherwise noted in groups. 2.03 FLUSH BOLTS A. Acceptable manufacturers and respective catalog numbers: Description Door Controls Int'l. Trimco Ives Rockwood Hager Manual - Metal Door 780F 3917 FB458 555 282D Manual - Wood Door 790F 3913 FB358 557 283D Automatic - Metal Door 842 3810 FB31P 1842 292D Automatic - Wood Door 962 ----- ------ 1962 296W Self Latching - Metal Door 845 3820 FB51P 1845 293D Self Latching - Wood Door 945 3825 FB61P 1945 294D Dust Proof Strike W/ Mtg. Plate 82 3911 DP2 570 280X B. Furnish a dustproof strike (82) for all bottom bolts. 2.04 LOCKS AND LATCHES A. Acceptable manufacturers and respective catalog numbers: Description Dorma Schlage Yale PDQ Heavy Duty Grade 1 Cylindrical C800 ND 5400 GT Std. Duty Grade 2 Cylindrical CL700 A-L 5300 GP Light Duty Grade 2 C300 F 4300 SM B. Furnish lever design as follows: Dorma LC or equal. C. Furnish lock types and functions as specified in the hardware schedule, and as follows: 1. Provide 2-3/4" backset. 2. Provide 4-7/8” x 1-1/4” ANSI strike for installation in wood or hollow metal doors and frames. 3. Strike lip length shall be sufficient to protect trim, but not to project more than 1/8" beyond trim , frame, or inactive leaf. 2.05 EXIT DEVICES A. Acceptable manufacturers and respective catalog numbers: Description Dorma VonDuprin Yale PDQ Wide Stile Rim 9300 98 Rim 7100 6200R Wide Stile Surf. Vert. Rod 9400 9827 7110 6200V B. Furnish exit device types and functions as specified in the hardware schedule. C. Lever handles supplied with exit devices shall match the design specified for locks and latches 2.06 PULLS, PUSHBARS, PUSH/PULL PLATES A. Acceptable manufacturers and respective catalog numbers: Push/Pull set 1" dia. straight pull 10”CTC:

Page 10: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

Don-Jo Trimco Hiawatha Burns Rockwood Hager 20147 1731 1081LBP x 536B 422 x 26C 11147 153

Push/Pull set 1" dia. offset pull 10”CTC: Don-Jo Trimco Hiawatha Burns Rockwood Hager 1157147 1737 1081LBP x 658A 422 x 39C 15747 159

1” dia. offset pull 10” CTC: Don-Jo Trimco Hiawatha Burns Rockwood Hager 1157 1191-3 658A 39C 157 12J

.75" dia. straight pull 6” CTC: Don-Jo Trimco Hiawatha Burns Rockwood Hager 15 1194-1 523E 25A 106 3E

Push plate 4” x 16”: Don-Jo Trimco Hiawatha Burns Rockwood Hager 71 1001-3 200F 54 70C 30S

Pull plate 4” x 16” with 8” CTC half round pull: Don-Jo Trimco Hiawatha Burns Rockwood Hager 7138 1014-3B 200F x 581 54 x 21B 70C x 126 31G

B. length of push bars shall be sufficient to mount each end on center of stile. Pushbars on flush doors shall be 3" less than door width. 2.07 DOOR CLOSERS A. Acceptable manufacturers and respective catalog numbers: Description Dorma Norton LCN PDQ Yale Heavy Duty 8900 7500 4041 7100 4400 Medium Duty 8600 8301 1460 5300 3301 Standard Duty - No Cover 7400 1600 1260 3100 50 B. Furnish complete with mounting brackets, drop plates, spacers, special shoes, and thru bolts as may be required by the door and frame conditions. C. Unless otherwise detailed in the hardware schedule, install closers on the room side of corridor doors, stair side of stairway doors and interior side of exterior doors. 2.08 PROTECTIVE PLATES A. Acceptable manufacturers: Don-Jo Trimco Hiawatha Burns Rockwood Hager B. Provide plates as indicated in the hardware groups. C. All kick plates shall be 10" high and 2" less door width for single doors and 1" less door width for pairs. D. All mop plates shall be 4" high and 1" less door width. E. All armor plates shall be 34” high and 2" less door width for single doors and 1" less door width for pairs. F. Thickness shall be .050" (16 gauge) and all plates shall be beveled all four edges (B4E). G. At panel door types, adjust plate heights to work with panels on doors. 2.09 OVERHEAD STOPS A. Acceptable manufacturers and respective catalog numbers: Description Dorma Rixson Glynn-Johnson Heavy Duty Surface 900 9 90 Heavy Duty Concealed 910 1 100 Standard Duty Surface 700 55 450 B. If a regular arm door closer being supplied limits the swing of a door to less than that required for the door to reach a wall stop, an overhead stop must be supplied. Furnish an overhead stop if a door opens against equipment, casework, sidelights, or other objects that would make wall stops inappropriate, and as specified in the hardware schedule.

Page 11: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

2.10 WALL STOPS A. Acceptable manufacturers and respective catalog numbers: Description Door Controls Int'l Trimco Ives Hager Concave Wrought Wall Bumper 3211T 1270WV WS407CCV 236W Hvy. Duty 3-3/4" Projection Wall Stop 3260X 1205 WS11X 255W Hvy. Duty Wall Stop/Automatic Holder 3487X 1254 WS40 326W B. Furnish wall stops as specified in the hardware schedule. Where specified wall stop is not applicable, but a different wall mounted stop will function correctly, supply the correct wall stop. C. Wall stops shall not be mounted to casework, cabinet work, sidelights, or equipment. D. Where wall stops are specified but not applicable, supply an overhead stop as specified in paragraph 2.12.B 2.11 ELECTROMAGNETIC DOOR HOLDERS A. Acceptable manufacturers and respective catalog numbers: Description Dorma Rixson LCN Flush Wall Mount - Std. Catch Plate EM-504-24120 FM998 SEM7850 B. Provide the voltage as required by electrical. 2.12 THRESHOLDS, SWEEPS, WEATHERSTRIP, DRIP CAPS, GASKET, ASTRAGALS A. Acceptable manufacturers and respective catalog numbers: Description National Guard Reese Pemko Threshold 425E S205 171A Sweeps 200N 323 315N Weatherstrip 135N 815 303S Drip Caps 16 R201 346 Gasket 5050 638 S88 Meeting Stile Astragals 115N 103 305N B. Where specified in the hardware schedule, furnish the above products unless otherwise detailed. 2.13 DOOR HARDWARE FINISHES A. Unless indicated otherwise in the groups provide finishes as follows: Hinges, exterior: US32D Hinges, interior: US26D Flush Bolts: US26D Exit Devices: US32D Locks and Latches: US26D Pulls, Pushbars, Push/Pull Plates: US32D Coordinators: Prime Coat Painted Door Closers: Painted Aluminum Protective Plates: US32D Overhead Stops: Painted Aluminum Wall Stops: US32D/US26D Electromagnetic Door Holders: Painted Aluminum Gasket: Black Thresholds: Mill Aluminum Weatherstrip, Sweeps, Drip Caps: Clear Annodized Aluminum

Page 12: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

2.14 KEYING A. System: All locks and cylinders shall be keyed to a new master key system. B. Cylinder Type: Standard (non-I.C.) core cylinders. C. Quantity: Provide four (4) Master keys for each Master key set, and two (2) Change keys for each lock or cylinder. D. Meeting: The Hardware Supplier shall prepare a preliminary keying schedule, then meet with the owner to review it and make changes to accommodate the owners requirements. E. Delivery of Keys: Change keys shall be packed and delivered with each lock or cylinder. Master keys shall be as requested by the owner, to the individual and address that the owner specifies at the keying meeting. F. Key Cabinet: 1. Acceptable manufacturers and respective catalog numbers: Description M.M.F. Lund Telkee Two Tag Wall Mount Cabinet 201-8000-03 series 1200 series RWC/AWC series 2. Furnish one key cabinet with a capacity 1-1/2 times the number of key sets. Supply the owner with instructions on how to prepare the numerical, lock location, and key change number indexes, as well as how to maintain the key control system in the future. PART 3 EXECUTION 3.01 EXAMINATION A. Examine doors, frames, and related items for conditions that would prevent the proper application of finish hardware. Do not proceed until defects are corrected. 3.02 INSTALLATION A. Install each hardware item in strict compliance with the manufacturer's printed instructions and recommendations, using only fasteners supplied by, or called for by the manufacturer. B. Set units level, plumb and true to the line and location. Prepare and reinforce the attachment substrate as necessary for proper installation and operation. C. Mortise and cut to close tolerance and conceal evidence of cutting in the finished work. Drill and countersink units which are not factory prepared for anchorage fasteners. D. If manufacturers instructions do not call out a mounting location, refer to the Door and Hardware Institute's publication Recommended Locations for Architectural Hardware. Install 3211T wall stops to engage levers or pulls. E. Deliver to the owner one (1) complete set of installation and adjustment instructions, as well as all tools that were furnished with the hardware. 3.03 ADJUSTMENT AND CLEANING A. At final completion, adjust and check each operating item of hardware at each door to ensure proper operation and function of every unit. Lubricate any moving parts that do not operate freely, smoothly, and quietly using only lubricant as recommended by the manufacturer of the hardware item. Replace units that can not be adjusted or lubricated to operate properly. B. Instruct the owners personnel in the proper adjustments of the hardware as needed. C. Clean and restore hardware to the original finish. 3.04 HARDWARE SCHEDULE Group 1 Door 150B Hinges as required (by Alum.) 1 ea Push/pull set 20147 (Don-Jo) 1 ea Door closer 8916 AF89 – top jamb mount (Dorma) 1 ea Concealed overhead stop 910S (Dorma) 1 set Weatherstrip (by Alum.) 1 ea Threshold (by Alum.) 1 ea Sweep (by Alum.)

Page 13: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

Group 2 Door 150A Hinges as required (by Alum.) 1 ea Exit device 9300 x V103 (Dorma) 1 ea Electric strike ES62 (Dorma) 1 ea Door closer 8916 AF89 – top jamb mount (Dorma) 1 ea Concealed overhead stop 910S (Dorma) Access control system/phone entry system and electric strike power by others. Group 3 Door 153, 122B, 121B, 01B Hinges as required 1 ea Exit device 9300 x PRT03 (Dorma) 1 ea Door closer/stop 8916 x DS (Dorma) 1 set Weatherstrip 135N (NGP) 1 ea Threshold 425E (NGP) 1 ea Sweep 200N (NGP) 1 ea Drip cap 16 (NGP) Group 4 Door 160, 161 Hinges as required 1 ea Lock C880 – Storeroom (Dorma) 1 ea Door closer/stop/holder 8916 x DST (Dorma) 1 set Weatherstrip/gasketing 135N (NGP) 1 ea Threshold 425E (NGP) 1 ea Sweep 200N (NGP) 1 ea Drip cap 16 (NGP) Group 5 Door 162 Hinges as required 1 ea Deadbolt DB660 (Dorma) 1 ea Pull/plate 7138 (Don-Jo) 1 ea Door closer/stop/holder 8916 x DST (Dorma) 1 set Weatherstrip 135N (NGP) 1 ea Threshold 425E (NGP) 1 ea Sweep 200N (NGP) 1 ea Drip cap 16 (NGP) Group 6 Door 121A, 122A, 21, 22, 221, 222, 321, 322 Hinges as required 1 ea Exit device F9300 x YC23 (Dorma) 1 ea Door closer 8616 (Dorma) 1 ea Wall stop 3211T (DCI) 1 set Gasketing 5050 (NGP) Group 7 Door 125, 126 Hinges as required 2 ea Exit devices F9400 x LB x No Trim (Dorma) 2 ea Door closers 8616 x AF89P (Dorma) 2 ea Electromagnetic holders EM-504-24120 (Dorma) 1 set Gasketing 5050 (NGP) 1 set Meeting stile astragal 115N (NGP) Group 8 Door 158 Hinges as required 1 ea Lock CL750 – Office/Entry (Dorma) 1 ea Wall stop 3211T (DCI)

Page 14: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

Group 9 Door 157 Hinges as required 1 ea Push/pull set 20147 (Don-Jo) 1 ea Wall stop 3211T (DCI) Group 10 Door 155, 156 Hinges as required 1 ea Lock CL740 – Privacy (Dorma) 1 ea Door closer 8616 (Dorma) 1 ea Wall stop 3211T (DCI) 1 set Gasketing 5050 (NGP) Group 11 Door 140 Hinges as required 1 ea Lock CL780 – Storeroom (Dorma) 1 ea Overhead stop 700S (Dorma) Group 12 Door 138, 149, 239, 249, 339, 349 Hinges as required 1 ea Lock CL710 – Passage (Dorma) 1 ea Door closer/stop 8616 x DS (Dorma) 1 set Gasketing 5050 (NGP) Group 13 Door 139, 02 Hinges as required 1 ea Lock CL770 – Classroom (Dorma) 1 ea Door closer 8616 (Dorma) 1 ea Wall stop 3211T (DCI) 1 set Gasketing 5050 (NGP) Group 14 Door 129, 137, 229, 233, 241, 329, 10 Hinges as required 1 ea Lock CL780 – Storeroom (Dorma) 1 ea Door closer/stop 8616 x DS (Dorma) 1 set Gasketing 5050 (NGP) Group 15 Not Used Hinges as required 1 ea Lock CL740 – Privacy (Dorma) 1 ea Wall stop 3211T (DCI) Group 16 Door 04 Hinges as required 1 set Automatic flush bolt – top only 840 x 8BFB (DCI) 1 ea Lock CL810 – Passage (Dorma) 1 ea Coordinator 600 series (DCI) 2 ea Mounting brackets – inline 600D (DCI) 2 ea Door closers 8616 x AF86P (Dorma) 2 ea Wall stops 3211T (DCI) 1 set Gasketing 5050 (NGP) 1 set Meeting stile astragals 115N (NGP)

Page 15: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

Group 17 Door 06 Hinges as required 1 ea Exit device F9300 x PRT03 - Storeroom (Dorma) 1 ea Door closer 8616 (Dorma) 1 ea Wall stop 3211T (DCI) 1 set Gasketing 5050 (NGP) Group 18 Door 12 Hinges as required 1 set Automatic flush bolt – top only 840 x 8BFB (DCI) 1 ea Lock CL753 – Entrance (Dorma) 1 ea Coordinator 600 series (DCI) 2 ea Mounting brackets – inline 600D (DCI) 2 ea Door closers 8616 x AF86P (Dorma) 2 ea Wall stops 3211T (DCI) 1 set Gasketing 5050 (NGP) 1 set Meeting stile astragals 115N (NGP) Group 19 Door 08, 13, 15 Hinges as required 1 set Automatic flush bolt – top only 840 x 8BFB (DCI) 1 ea Lock CL780 – Storeroom (Dorma) 1 ea Coordinator 600 series (DCI) 2 ea Mounting brackets – inline 600D (DCI) 2 ea Door closers 8616 x AF86P (Dorma) 2 ea Wall stops 3211T (DCI) 1 set Gasketing 5050 (NGP) 1 set Meeting stile astragals 115N (NGP) Group 20 Door 07, 11 2 ea Continuous Hinges CH51 (PBB) 1 set Automatic flush bolt – top only 840 x 8BFB (DCI) 1 ea Lock C870 – Classroom (Dorma) 1 ea Coordinator 600 series (DCI) 2 ea Mounting brackets 600D (DCI) 2 ea Door closers 8616 x AF86P (Dorma) 2 ea Wall stops 3211T (DCI) 1 set Gasketing 5050 (NGP) 1 set Meeting stile astragals 115N (NGP) 2 ea Armor Plates (Don-Jo) Group 21 Door 05, 09 Hinges as required 1 ea Lock CL780 – Storeroom (Dorma) 1 ea Door closer 8616 (Dorma) 1 ea Wall stop 3211T (DCI) 1 set Gasketing 5050 (NGP) Group 22 - Typical Resident Rated Corridor Storage - Door 130, 131, 132, 133, 134, 135, 136, 141, 142, 143, 144, 145, 146, 147, 148, 230, 231, 232, 234, 235, 236, 237, 238, 242, 243, 244, 245, 246, 247, 248, 330, 331, 332, 333, 334, 335, 336, 337, 338, 341, 342, 343, 344, 345, 346, 347, 348 1 ea Hinge (top) BB81 (PBB) 2 ea Spring hinges SP81 (PBB) 1 ea Lock C510 – Passage (Dorma) 1 ea Deadbolt DB660 (Dorma) 1 ea Overhead stop 700S (Dorma) 1 set Gasketing 5050 (NGP)

Page 16: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

Group 23 Door 240, 340, Typical Unit Entry 1 ea Hinge (top) BB81 (PBB) 2 ea Spring hinges SP81 (PBB) 1 ea Lock C510 – Passage (Dorma) 1 ea Deadbolt DB660 (Dorma) 1 ea Wall stop 3211T (DCI) 1 set Gasketing 5050 (NGP) 1 ea Threshold 410 or 417 (NGP) 1 ea Sweep C607 (NGP) 1 ea Viewer ULDV180 (Don-Jo) Note: Supply overhead stop 700S (Dorma) where unit entry door swings into another door. Group 23A 10 ea Spare unit entry deadbolts DB660 (Dorma) Group 24 Door 250, 350, Typical Unit Bathroom Hinges as required 1 ea Lock C340 – Privacy (Dorma) 1 ea Stop as required Group 25 Typical Unit Exterior Mechanical Hinges as required 1 ea Lock C880 - Storeroom (Dorma) 1 set Weatherstrip/Gasketing 5050 (NGP) 1 ea Threshold 410 (NGP) - if not provided with door kit 1 ea Sweep C607 (NGP) Group 26 Typical Unit Bedroom/Closet/Laundry - Single Hinges as required 1 ea Lock C310 – Passage (Dorma) 1 ea Stop as required Group 27 Typical Unit Bi-fold Doors 2 ea Cabinet knob 121 (Don-Jo) Balance of hardware by bi-fold door supplier Group 28 Provide kickplates as described in paragraph 2.09.B Provide the following plates: Mop plate at door 137 Kick plate at doors: 01B, 121B, 122B, 138, 149, 239, 249, 339, 349 Armor plate at doors: 04, 07, 08, 09, 11, 12, 13 Coordinate plate heights with paneled doors.

END OF SECTION

Page 17: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,
Page 18: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,
Page 19: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,
Page 20: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

TRTD BEAM (SEE PLAN)

TRTD JOISTS(SEE PLAN)

JOIST HANGER

3 5/8" LEDGER LOCK @ 12" OC

CONT LSL RIMFULL HEIGHT

2X6 STUD WALL(SEE PLAN)

CONT 2X8 TRTD LEDGER

2X6 STUD WALL(SEE PLAN)

DBL TOP PLAT 2ND FLRTRIPLE TOP PLAT 3RD FLR

7

S501

TREATED BEAM (SEE PLAN)

5/8" APA RATED SHEATHING ALL AROUND

(2) 2X12 PL

SIMPSON H1 TRUSS CONN AT EA TRUSS

ROOF TRUSS(SEE PLAN)

TRIPLE TOP PL

STUD WALL(SEE PLAN)

SE

E A

RC

H

ROOF TRUSS W/ LEG DOWN(SEE PLAN)

WALKWAY

LEG DOWN

VALLEY SETS(SEE PLAN)

ROOF TRUSS(SEE PLAN)

STUD WALL(SEE PLAN)

SIMPSON H1 TRUSS CONN

TRIPLE TOP PLATE

SHEATHING

2x OUTRIGGER

RT3A AT EACH LOOKOUTWITHIN 6'-0" OF CORNERS.EVERY OTHER RAFTER ELSEWHERE

2x6 NAILED TO EAVERT TRUSSMEMBER EXCEEDING5'-0" IN LENGTH

GABLE END TRUSS

8d NAILS @ 6" OC

2x10 RIBBON

SE

E A

RC

H

HE

EL H

EIG

HT

MONO ROOFTRUSS W/ EXTENDED TOP CHORD (SEE PLAN)

1/2" OSB GUSSET

2x6 @ 24" OC (TYP)

SIMPSON H1 TRUSS CONNECTOR(OR EQUAL)

STUD WALL(SEE PLAN)

(4) 10d NAILS(TYP)

ROOF SHEATHING(SEE PLAN)

(3) 10d NAILS(TYP)

2x6 @ 24" OC W/PLYWOOD SHEATHING

NOTE:TRUSS SUPPLIER SHALL PROVIDESEPARATE INDIVIDUAL CORRIDORTRUSSES AT JOG LOCATIONS ALONG THE CORRIDOR AND/OR EDGE

SE

E A

RC

H

2x6 "V" BRACING AT FACE OF TRUSS W/ (2) 16d NAILSAT EA TRUSS(SEE PLAN)

TRIPLE TOP PLATE

2x6 SUPPORT DN

PROVIDE (2) 2x6 AT SPRINKLER PIPE HANGERS

PROVIDE A35 FRMG ANGLE FROM 2x6 BRACE TO TOP PLATES

FLOOR SHEATHING

16d NAILS @ 3" OC

2X LADDER TRUSS

16d NAILS @ 3" OC

3/8" STIFF PLTYP AT ALLCOL EA SIDEOF BM WEB

STEEL COL (SEE PLAN)

1/2" CAP PLATE W/ (4) 3/4" DIA BOLTS

3/16

1/4

TOP CHORD BRGFLOOR TRUSSES(SEE PLAN)

2X TOP PLATE W/1/2" DIA THRU BOLTS@ 48" OC STAGGERED

BEAM (SEE PLAN)

CONC FTG(SEE PLAN)

4' -

0"

PR

OT

EC

TIO

N

3'-0"

MIN

FR

OS

T

CIP WALL(SEE PLAN)

STRUCT FILL PER SOILS REPORT

#6 @ 12" OC VERT, EXT FACE

#3 TIES @ 12" OC

(3) #6 BARS T&B, EXTEND BARS 24" (MIN) PAST EDGE OF OPNG

(3)

SID

ES

#6 @

9"

OC

HO

RIZ

, E

A F

AC

E

(3)

SID

ES

#7 @

12

" O

C H

OR

IZ, E

A F

AC

E

45.00°

CONC FTG W/#5 @ 11" OC EW, TOP & BOTT

3' - 0"

1' -

4"

COMPACTED GRANULAR FILL

CONC SLAB(SEE PLAN)

PT SLAB(SEE PLAN)

CIP BEAM

2' - 0"

DRAIN BTWN FOOTINGS

#5 @ 12" OC VERT, INT FACE

#4 @ 18" OC

1" DIA WEEPS @ 48" OC

L3x3x1/4" CONT W/ 1/2" DIA ANCHORS @ 16" OC (4) SIDES

BAR GRATING (SEE ARCH)

STUD WALL (SEE PLAN)

FLOOR SHEATHING

WOOD FLOORTRUSS (SEE PLAN)

DBL TOP PLAT 2ND FLRTRIPLE TOP PLAT 3RD FLR

STUD WALL(SEE PLAN)

GYP TOPPING (SEE ARCH)

CONT 2X12 TREATED LEDGER W/ 5" LEDGERLOKFASTENERS @ 6" OCSTAGGERED

JOIST HANGER

TREATED JOISTS

TREATED RIM BEAM

CONT (2) 2X12 RIM

SHEATHING

2X6 CONT BOTTRIM AT PERGOLA

BEAM (SEE PLAN)

CORRIDOR FRAMING (SEE PLAN)

STUD WALL(SEE PLAN)

HANGER

2X TOP PLATE W/ 1/2" DIA THRU BOLTS AT48" OC STAGGERED

SOLID BLOCKING

FLOOR SHEATHING

6"

BEAM(SEE PLAN)

RAISED BRG FLOOR TRUSS FULL BRG ON BM(SEE PLAN)

FLOOR SHEATHING

GYPCRETE(SEE ARCH)

PROVIDE FULL BRG OF TRUSS OVER FLUSH HEADER

FLOOR TRUSS(SEE PLAN)

MIN 4"

MAX 12"

MIN

4"

MA

X 1

2"

MIN 4"

MAX 12"

MIN 4"

MAX 12"

SILL PLATE ANCHOR BOLT PLACEMENT

MIN (2) ANCHORS PER PLATE

FLOOR JOISTAND SHEATHING(SEE PLAN)

STUD BRG WALL (SEE PLAN)

STUD BRG WALL (SEE PLAN)

FLR JOIST(SEE PLAN)

CONT 2x4 BLOCKING

DBL TOP PLAT 2ND FLRTRIPLE TOP PLAT 3RD FLR

2x8 CONT RIBBON

TREATED BEAM (SEE PLAN)

5/8" APA RATED SHEATHING ALL AROUND

TRTD POST

TREATED JOISTS(SEE PLAN)

(2) 2x12 PL

7

S501

CONCEALED FLANGE HANGER HUSC 212-2 OR HUSC212-3 W/ SIMPSON SDSCONN SCREWS

SIM:BEAMS AND JOISTS BOTH SIDES

STUD WALL (SEE PLAN)

FLOOR SHEATHING

STUD WALL(SEE PLAN)

GYP TOPPING (SEE ARCH)

PERGOLA(BY OTHERS)

SHEATHING

2X12 CONT TRTD LEDGER W/ (3) 3/8" DIA X 5" LG LAG SCREWS AT EACH STUD (16" OC)

(2) 2X10 CONT BLKG

DOUBLE TOP PLATE

BLOCK SOLIDFASTEN LEDGER TO BLKG W/ (2) 1/4" DIA X 3-1/2" LG SDS SCREWS @ 12" OC(4 PER STUD SPACE)FOR PERGOLA CONN

BEAM(SEE PLAN)PROVIDE FULL BRG OF EA TRUSS OVER FLUSH HEADER

RAISED BRG FLOOR TRUSS FULL BRG ON BM(SEE PLAN)

FLOOR SHEATHING

GYPCRETE(SEE ARCH)

CONC FTG(SEE PLAN)

PR

OT

EC

TIO

N

3'-0"

MIN

FR

OS

T

CIP WALL(SEE PLAN)

STRUCT FILL PER SOILS REPORT

#6 @ 8" OC VERT, EXT FACE

45.00°

CONC FTG W/#5 @ 11" OC EW, TOP & BOTT

3' - 0"

1' -

4"

COMPACTED GRANULAR FILL

CONC SLAB(SEE DTL 13/S500)

2' - 0"

DRAIN(SEE ARCH)

#5 @ 12" OC VERT, INT FACE

1" DIA WEEPS @ 48" OC

PT SLAB(SEE DTL 10/S501)

CONC SLAB WALKWAY(SEE PLAN)

SIM

#6 @ 12" OC HORIZ, EA FACE, ALL SIDES

VERIFY RAIL AND INSERT W/ ARCH

1400 C

orp

ora

te C

ente

r C

urv

e, S

uit

e 100

Eag

an, M

N 55121

Phone:

651-7

60-8

311

ww

w.r

eear

chit

ectu

re.c

om

Rea

l E

stat

e E

quit

ies

Arc

hit

ectu

re, L

LC

PROJECT NO:

DATE:

REVISIONS:

SH

EE

T T

ITLE

:P

RO

JE

CT

:

2/5

/2019

11:1

0:0

5 A

MH

:\P

roje

ct

Lo

ca

l File

s\1

1-1

8-0

94

7 -

Vill

ag

e C

oo

p L

ove

lan

d\1

118

094

7 -

VIL

LA

GE

CO

OP

LO

VE

LA

ND

- R

18

.rvt

02/07/19

VIL

LA

GE

CO

OP

ER

AT

IVE

OF

LO

VE

LA

ND

DE

TA

ILS

11.18.0947

01/07/19

LO

VE

LA

ND

, C

OL

OR

AD

O

S504

CD SET 01/07/19

REF. SHEET:

SECTION 3/4" = 1'-0"

S104

S504

1

REF. SHEET:

SECTION 3/4" = 1'-0"

S104

S504

2

REF. SHEET:

SECTION 3/4" = 1'-0"

S108

S504

3

REF. SHEET:

SECTION 1/2" = 1'-0"

S108

S504

5

REF. SHEET:

SECTION 1/2" = 1'-0"

S108

S504

7

REF. SHEET:

SECTION 3/4" = 1'-0"

S104

S504

6

REF. SHEET:

SECTION 1/2" = 1'-0"

S100

S504

9

REF. SHEET:

SECTION 3/4" = 1'-0"

S104

S504

8

REF. SHEET:

SECTION 3/4" = 1'-0"

S104

S504

4

REF. SHEET:

SECTION 3/4" = 1'-0"

S104

S504

12

REF. SHEET:

SECTION 3/4" = 1'-0"S504

11

REF. SHEET:

SECTION 3/4" = 1'-0"

S104

S504

14

REF. SHEET:

SECTION 3/4" = 1'-0"

S104

S504

15

REF. SHEET:

SECTION 3/4" = 1'-0"

S104

S504

16

REF. SHEET:

SECTION 3/4" = 1'-0"

S104

S504

13

REF. SHEET:

SECTION 1/2" = 1'-0"

S100

S504

10

1

1

1 ADD 1 02/07/19

Page 21: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

5430 Douglas Drive North Crystal, MN 55429 763.585.6742 main [email protected] email www.steeneng.com web

Designing Sensible Cost Effective Solutions

February 7, 2019

ADDENDUM (ADDN) NO. 1

TO PLANS AND SPECIFICATIONS FOR:

VILLAGE COOPERATIVE OF LOVELAND

LOVELAND, CO

STEEN #REE201802

The following additions, deletions, corrections or clarifications are hereby made to the original

plans and specifications, issued January 7, 2019 and become part of these Construction

Documents. Items herein take precedence over items in the plans and specifications, which they

modify or supplement.

The main trade concerned with each Addenda item is primarily responsible, but certain attendant

work of other trades may also be affected. This Contractor is cautioned that while the items

specified below are general, it is assumed that all work required to implement each Addenda

item is included.

DRAWINGS

E5.0 – Revised and reissued (attached).

1. Revised feeder in Main Switchboard Schedule.

END OF ADDN NO. 1

Page 22: Addendum: No. 1 · Test report(s) by independent testing agency itemizing compliance and acceptable to authorities ... (PVC) with integral color; with factory-installed glazing, hardware,

REVISIONS:

1400

Co

rpo

rate

Cen

ter

Curv

e, S

uit

e 100

Eag

an,

MN

55121

Phon

e: 6

51

-76

0-8

310

ww

w.r

eear

chit

ectu

re.c

om

DATE:

PROJECT NO:

SH

EE

T T

ITLE

:

Rea

l E

stat

e E

qu

itie

s A

rch

itec

ture

, L

LC

PR

OJE

CT

:

.

.

.

.

01-07-2019

REE201802

VIL

LA

GE

CO

OP

ER

AT

IVE

OF

LO

VE

LA

ND

LO

VE

LA

ND

, C

OLO

RA

DO

01-07-2019

E5.0

EL

EC

TR

ICA

L R

ISE

R

DIA

GR

AM

AN

D S

CH

ED

ULE

S

ADDN #1 02-07-19