    ADAMS-COLUMBIA

    ELECTRIC COOPERATIVE 

    Rates

    Board Approved 1/27/16

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    2/34

      1

    TABLE OF CONTENTS

    RATE CODE DESCRIPTIONS ......................................................................................................2 

    RATE CODE DESCRIPTIONS (continued)...................................................................................3 

    RATE DESCRIPTIONS (continued) ..............................................................................................4 

    RATE SCHEDULE AVAILABILITY AND DISCLAIMER .........................................................5 

    GENERAL SINGLE-PHASE, FARM & RESIDENTIAL SERVICE............................................6 

    GENERAL SERVICE TIME-OF-DAY (TOD) ..............................................................................7 

    DAIRY FARM SERVICE ...............................................................................................................8 

    ELECTRIC SPACE HEATING ......................................................................................................9 

    ELECTRIC SPACE HEATING TIME-OF-DAY (TOD) .............................................................11 

    INTERRUPTIBLE - DUAL FUEL ELECTRIC SPACE HEATING ...........................................13 

    COMMERCIAL SERVICE (3ϕ) ...................................................................................................15 

    COMMERCIAL SERVICE (3ϕ) TIME-OF-DAY (TOD) ............................................................16 

    LARGE POWER SERVICE..........................................................................................................17 

    LARGE POWER SERVICE (OVER 1000 KVA) ........................................................................19 

    LARGE POWER ECONOMIC DEVELOPMENT (OVER 10,000 KVA) ..................................20 

    LARGE POWER SERVICE – TIME-OF-DAY (TOD) ...............................................................21 

    IRRIGATION SERVICE - NO CONTROL..................................................................................23 

    IRRIGATION SERVICE NO CONTROL - COINCIDENT ........................................................25 

    IRRIGATION SERVICE OFF PEAK ...........................................................................................27 

    YARD LIGHT RENTAL FACILITIES ........................................................................................29 

    STREET LIGHT RENTAL FACILITIES .....................................................................................30 

    RENEWABLE GENERATION RATE – CLOSED RATE ..........................................................31 

    RENEWABLE GENERATION RATE – CLOSED RATE ..........................................................32 

    RENEWABLE GENERATION RATE .........................................................................................33 

    Effective dates referenced in this document indicates that the rate will be effective for all

    invoices prepared on or after this date, regardless of the period being billed.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    3/34

      2

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate DescriptionsFriendship, Wisconsin Effective: 9/8/14

    RATE CODE DESCRIPTIONS

    Type Rate Code Description Page

    Residential  21 Single-phase service for full-time residential use. For accounts

    with maximum demand less than 40kW.

    6

    Residential TOD

    T1 Single-phase time-of-day (TOD) service for full-time residentialuse.

    7

    Residential Resistance Heat

    E1H Second-meter electric service for electric resistant heat (only) forfull-time residential use.

    9

    Residential 

    Resistance Heat(plus)

    X1H Second-meter electric service for electric resistant heat (only) forfull-time residential use where other loads have been added to thesecond meter service.

    9

    Residential Resistance HeatTOD

    H1T Second-meter electric service for time-of-day (TOD) electricresistant heat (only) for full-time residential use.

    11

    Residential Resistance HeatTOD (plus)

    X1T Second-meter electric service for time-of-day (TOD) electricresistant heat (only) for full-time residential use where other loadshave been added to the second meter service.

    11

    Residential InterruptibleResistance Heat

    I1H Sub-metered second-meter electric service for interruptibleelectric resistant heat (only) for full-time residential use in a homethat has back up fossil fuel heat. This Is A Closed Rate (notavailable for new connects)

    13

    Residential InterruptibleResistance Heat

    J1H Second-meter electric service for interruptible electric resistantheat (only) for full-time residential use in a home that has back upfossil fuel heat.

    13

    General

    Service 42 Single-phase service for non-full-time residential (second homes,

    cottages) use, including sheds, garages, outbuildings, town halls,churches, stock waterers and camper services). For accounts withmaximum demand less than 40kW.

    6

    General

    Service TODT2 Single-phase time-of-day (TOD) service for non-full-time

    residential (second homes, cottages) use, including sheds,garages, outbuildings, town halls, churches, stock waterers andcamper services.

    7

    General

    Service Resistance Heat

    E2H Second-meter electric service for electric resistant heat (only) fora home for non-full-time residential (second homes, cottages) use.

    9

    General

    Service 

    Resistance Heat(plus)

    X2H Second-meter electric service for electric resistant heat (only) fornon-full-time residential (second homes, cottages) use whereother loads have been added to the second meter service.

    9

    General

    Service 

    Resistance HeatTOD

    H2T Second-meter electric service for time-of-day (TOD) electricresistant heat (only) for non-full-time residential (second homes,cottages) use.

    11

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    4/34

      3

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate DescriptionsFriendship, Wisconsin Effective: 9/8/14

    RATE CODE DESCRIPTIONS (continued)

    Type Rate Code Description Page

    Residential

    Seasonal Resistance HeatTOD (plus)

    X2T Second-meter electric service for time-of-day (TOD) electric

    resistant heat (only) for non-full-time residential (second homes,cottages) use where other loads have been added to the secondmeter service.

    11

    Residential Seasonal InterruptibleResistance Heat

    J2H Second-meter electric service for interruptible electric resistantheat (only) for non-full-time residential (second homes, cottages)use in a home that has back up fossil fuel heat.

    13

    Dairy Farm  DF Single- or three-phase service for dairy farm accounts withmaximum demand less than 100kW.

    8

    Small

    Commercial 

    23 Single-phase service for commercial accounts with maximumdemand less than 40kW. Includes services like convenience

    stores, small businesses, county parks, campgrounds, billboards,grain dryers and irrigation pivot-only.

    6

    Small

    Commercial TOD

    T3 Single-phase time-of-day (TOD) service for non-residentialaccounts with maximum demand less than 40kW. Includesservices like convenience stores, small businesses, county parks,campgrounds, billboards, grain dryers and irrigation pivot-only.

    7

    Small

    Commercial Resistance Heat

    E3H Second-meter single-phase electric service for electric resistantheat (only) for commercial accounts.

    9

    Small

    Commercial Resist. Heat (plus) 

    X3H Second-meter single-phase electric service for electric resistantheat (only) for commercial accounts where other loads have beenadded to the second meter service.

    9

    Small

    Commercial Resist. Heat TOD 

    H3T Second-meter single-phase electric service for time-of-day (TOD)electric resistant heat (only) for non-residential accounts.

    11

    Small

    Commercial InterruptibleResistance Heat

    J3H Second-meter single-phase electric service for interruptibleelectric resistant heat (only) for non-residential accounts that have back up fossil fuel heat. Includes services like billboards, andirrigation pivot-only services.

    13

    Commercial  34 Three-phase electric service for non-residential accounts(requiring transformer capacity less than 50 kVA).

    15

    Commercial 

    TOD 34T Three-phase time-of-day (TOD) electric service for non-

    residential accounts (requiring transf. capacity less than 50 kVA).16

    Large Power  63 Single-phase electric service for large commercial services(generally requiring transformer capacity of 50 kVA or more).

    17

    Large Power Resistance Heat

    E4H Second-meter three-phase electric service for electric resistantheat (only) in a large commercial establishment.

    9

    Large Power Resistance Heat TOD 

    H4T Second-meter three-phase electric service for time-of-day (TOD)electric resistant heat (only) for a large commercial establishment.

    11

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    5/34

      4

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate DescriptionsFriendship, Wisconsin Effective: 4/1/16

    RATE DESCRIPTIONS (continued)

    Type Rate Code Description Page

    Large Power 

    InterruptibleResistance Heat

    J4H Second-meter three-phase electric service for interruptible electric

    resistant heat (only) for a large commercial establishment that has back up fossil fuel heat.

    13

    Large Power  64 Three-phase electric service for large commercial services (gen.req. transformer of 50 kVA or more). Demand (kW) is billed.

    17

    Large Power 

    TODEBR Single- and three-phase non-irrigation time-of-day (TOD) electric

    service. For accounts with maximum demand of 40kW or more.21

    Industrial Various

    Three-phase electric service for very large commercial services(requiring transformer capacity of 1000 kVA or more).

    19

    Industrial EconomicDevelopment Rate 

    VariousThree-phase electric service for very large commercial services(requiring transformer capacity of 10,000 kVA or more).

    20

    Irrigation  M6 Firm (no load control) irrigation service for farm irrigation pumpsof 15 HP and greater, billed 12 monthly facility charges.

    23

    Irrigation  M66 Firm (no load control) irrigation service for farm irrigation pumpsof 15 HP and greater, billed 6 monthly facility charges but sameannual facility charges as M6.

    23

    Irrigation  MC6 Coincident demand billed firm (no load control) irrigation servicefor farm irrigation pumps of 15 HP and greater, billed 12 monthlyfacility charges. EXPERIMENTAL RATE ONLY –NOT OPEN 

    25

    Irrigation  MC66 Coincident demand billed firm (no load control) irrigation servicefor farm irrigation pumps of 15 HP and greater, billed 6 monthlyfacility charges but same annual facility charges as M6.

    EXPERIMENTAL RATE ONLY – NOT OPEN 

    25

    Irrigation   N6 Controlled irrigation service for non-farm irrigation pumps of 15HP and greater, billed 12 monthly facility charges.

    27

    Irrigation   N66 Controlled irrigation service for non-farm irrigation pumps of 15HP and greater, billed 6 monthly facility charges but same annualfacility charges as N6.

    27

    Irrigation  P6 Controlled irrigation service for farm irrigation pumps of 15 HPand greater, billed 12 monthly facility charges.

    27

    Irrigation  P66 Controlled irrigation service for farm irrigation pumps of 15 HPand greater (billed 6 monthly facility charges but same annual facility charges as P6) 

    27

    Yard Light  YL Available to all members for lighting yards and other areas. 29

    Street Light  SL Available to Townships, unincorporated municipalities and selectmembers for lighting of streets, parking lots, etc.

    30

    Renewable

    Generation 

    RGS For members receiving service with renewable energy facilitiesnot greater than 20 kW in capacity connected in parallel withACEC. THIS IS A CLOSED RATE

    31

    Renewable

    Generation 

    RGL For members receiving service with renewable energy facilitiesgreater than 20 kW capacity connected in parallel with ACEC.THIS IS A CLOSED RATE

    32

    Renewable

    Generation 

    RG For members receiving service with renewable energy facilitiesconnected in parallel with ACEC.

    33

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    6/34

      5

    RATE SCHEDULE AVAILABILITY AND DISCLAIMER

    The availability of a Rate Schedule for a member is based on the member meetingqualifications of the availability clause and other terms of the Rate Schedule. RateSchedules are available upon request and it shall be the member’s responsibility to

    see that he/she is charged the rate for which he/she qualifies. In some cases themember may be eligible to take service under more than one rate.

    By request the Cooperative will advise the member in the selection of the rate thatwill give him/her the lowest cost of service based on information provided to theCooperative; however, the responsibility for the selection of the rate lies with themember. After the member has selected the rate under which he/she elects to takeservice, or when the type or capacity of service(s) needed requires a change toanother rate, the member will not be permitted to change from that rate to anotherrate until at least 12 months have elapsed. An exception to this elapsed timerequirement will be made if the service no longer meets the availability clause ofthe Rate Schedule. Additionally, it is the responsibility of the member to notify theCooperative of any change that affects the rate or charge for service.

     No refund will be made of the difference in charges under different rates applicableto the same class of service.

    (Source – ACEC Service Rules and Regulations)

    Adams-Columbia Electric Cooperative provides Internet access to

    our rate schedules for the convenience of our membership. While

    we strive to keep these documents up to date, please note that the

    rate schedules and details included therein are subject to change at

    the discretion of the Cooperative’s board of directors. Users should

    note that the schedules provided on this web site are not the official

    documents and users assume responsibility for reliance upon rate

    schedules in electronic format. Please contact the Cooperative with

    any questions you may have.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    7/34

      6

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes 21, 23, 42Friendship, Wisconsin Effective: 04/07/14

    Rate Schedule: GS

    GENERAL SINGLE-PHASE, FARM & RESIDENTIAL SERVICE

    1. AVAILABILITYAvailable to all single-phase accounts requiring less than 50 kVA of transformer capacity, orwhose measured maximum demands for eleven (11) of the past twelve (12) months has beenless than 40 kW.  Service is subject to the established rules and regulations of theCooperative.

    2. TYPE OF SERVICESingle-phase, 60 cycles at available secondary voltage

    3. RATEFacility Charge: $ 1.0288 per day

    Energy Charge: All energy @ 10.5¢ per kWh

    4. MINIMUM MONTHLY BILLThe facility charge specified above, except where multiple units are served.(See ACEC Policy #11-3).

    5. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    6. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    7. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    8/34

      7

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes T1, T2, T3Friendship, Wisconsin Effective: 04/07/14

    Rate Schedule: GS-TOD

    GENERAL SERVICE TIME-OF-DAY (TOD)

    1. AVAILABILITYAvailable to members for all single-phase uses requiring less than 50 kVA of transformercapacity, or whose measured maximum demands for eleven (11) of the past twelve (12)months has been less than 40 kW. The capacity of individual motors served under thisschedule shall not exceed 10 HP without prior approval of the Cooperative. Service issubject to the established rules and regulations of the Cooperative.

    2. TYPE OF SERVICESingle-phase, 60 cycles at available secondary voltages.

    3. RATEFacility Charge: $1.0288 per dayEnergy Charge: On-Peak @ 25.1¢ per kWh

    Off-Peak @ 6.4¢ per kWh

    On-Peak:October 20 - April 20: 5:00 p.m. to 8:00 p.m.

    Monday through Friday, except HolidaysApril 21 – October 19: 1:00 p.m. to 8:00 p.m.

    Monday through Friday, except Holidays

    Off-Peak: All other hours

    4. MINIMUM CHARGEThe minimum monthly charge under the above rate shall be the calculated facility chargenoted above, except where multiple units are served. (See ACEC Policy #11-3).

    5. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with theCooperative’s wholesale power bill power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    6. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    7. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    9/34

      8

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code DFFriendship, Wisconsin Effective: 04/07/14

    Rate Schedule: DF

    DAIRY FARM SERVICE

    1. AVAILABILITYAvailable to all active dairy farms whose measured maximum demand for eleven (11) of the past twelve (12) months has been less than 100 kW. Service is subject to the establishedrules and regulations of the Cooperative.

    2. TYPE OF SERVICESingle-phase and three-phase at available secondary voltage.

    3. RATEFacility Charge: $ 1.0288 per dayEnergy Charge: All energy @ 10.5¢ per kWh

    4. MINIMUM MONTHLY BILLThe minimum charge shall be the calculated facility charge noted above, except wheremultiple units are served. (See ACEC Policy #11-3)

    5. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    6. TERMS OF PAYMENT

    The above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    7. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

    8. CONDITIONS OF SERVICEA.  Dairy farms on this rate must be active dairy producing operations listed with the WI

    Department of Agriculture.

    B. 

    Active dairy farms whose measured maximum demand for two (2) or more of the pasttwelve (12) months has been equal to or greater than 100 kW will be billed under theLP-1 rate.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    10/34

      9

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes E1H, E2H, E3H, E4H,Friendship, Wisconsin X1H, X2H, X3H

    Effective: 4/1/16Rate Schedule: EH

    ELECTRIC SPACE HEATING

    1. AVAILABILITYAvailable to all members who use separately metered electric energy for heating, conformingto the specifications set forth hereunder, and who are receiving service at the same location forother usages. Service is subject to the established rules and regulations of the Cooperative.

    2. TYPE OF SERVICESingle- or three-phase, 60 cycles at available secondary voltage, separately metered.

    3. RATEFacility Charge: $8.50 per month (second meter charge) 

    Energy Charge: All energy @ 9.8¢ per kWh (September – May billing periods)All energy @ 15.0¢ per kWh (June – August billing periods)

    All energy @ 10.5¢ per kWh all months for X1H, X2H, and X3H rate codes.

    4. MINIMUM CHARGEThe minimum monthly charge under above rate shall be the facility charge noted above.

    5. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    6. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment charge onthe unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    7. CONDITIONS OF SERVICEA. The member shall provide the complete service entrance according to the

    Cooperative’s specifications necessary for the separate electric heat meter.

    B. Space heating equipment shall be permanently connected and as far as practicable,shall be 240 volt.

    C. The minimum connected heating load shall be 5000 watts resistance-type heat.

    D. Not more than 6000 watts of resistance-type space heating equipment shall becontrolled by a single thermostat or manually operated switch.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    11/34

      10

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes E1H, E2H, E3H, E4H,Friendship, Wisconsin X1H, X2H, X3H

    Effective: 4/1/16Rate Schedule: EH

    ELECTRIC SPACE HEATINGPage 2 of 2

    E. Electric water heaters may not be connected to this service.

    F. Supplemental resistance heating in heat pumps may be included on this rate.

    G. Central heating systems such as electric furnace and systems that include airconditioning will not be permitted on this rate; however, Schedule GS-TOD isavailable.

    8. TAXES AND FEES

    The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

    9. NON-COMPLIANCE (X1H, X2H, and X3H rate codes)Members who had load on their electric heat panel that did not comply with the conditions ofthis rate were transferred to the X rate until the non-complying load is removed.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    12/34

      11

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes H1T, H2T,Friendship, Wisconsin H3T, H4T, X1T, X2T

    Effective: 4/1/16Rate Schedule: EH-TOD

    ELECTRIC SPACE HEATING TIME-OF-DAY (TOD)

    1. AVAILABILITYAvailable to all members who use separately metered electric energy for heating, conformingto the specifications set forth hereunder, and who are receiving service at the same locationfor other usages. Service is subject to the established rules and regulations of theCooperative.

    2. TYPE OF SERVICESingle- and three-phase, 60 cycles at available secondary voltage, separately metered.

    3. RATEFacility Charge: $8.50 per month (second meter charge)Energy Charges: On-Peak @ 23.9¢ per kWh

    On-Peak @ 25.1¢ per kWh for X1T and X2T rate codesOff-Peak @ 5.25¢ per kWh (September – May billing periods)Off-Peak @ 15.0¢ per kWh (June – August billing periods)Off-Peak @ 6.4¢ per kWh all months for X1T and X2T rate codes

    On-Peak:October 20 - April 20: 5:00 p.m. to 8:00 p.m.

    Monday through Friday, except HolidaysApril 21 – October 19: 1:00 p.m. to 8:00 p.m.

    Monday through Friday, except HolidaysOff-Peak: All other hours

    4. POWER COST ADJUSTMENT CHARGE

    Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    5. MINIMUM CHARGEThe minimum monthly charge under above rate shall be the facility charge noted above.

    6. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    7. CONDITIONS OF SERVICE

    A. The member shall provide the complete service entrance according to theCooperative’s specifications necessary for the separate electric heat meter.

    B. The member shall permanently install and operate approved type electric heatingequipment.

    C. Electric water heaters may not be connected to this service.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    13/34

      12

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes H1T, H2T,Friendship, Wisconsin H3T, H4T, X1T, X2T

    Effective: 01-11-10Rate Schedule: EH-TOD

    ELECTRIC SPACE HEATINGTIME-OF-DAY (TOD)

    Page 2 of 2

    8. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

    9. NON-COMPLIANCE (X1T and X2T rate codes)Members who had load on their electric heat panel that did not comply with the conditions ofthis rate were transferred to the time-of-day X rate until the non-complying load is removed.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    14/34

      13

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes I1H, I4H, J1H,Friendship, Wisconsin J2H, J3H, J4H

    Effective: 4/1/16Rate Schedule: EH-I

    INTERRUPTIBLE - DUAL FUEL ELECTRIC SPACE HEATING

    1. AVAILABILITYRestricted to areas of the Cooperative that have load management capabilities. Available toall members in these areas who use separately metered electric energy for heating,conforming to the specifications set forth hereunder, and who are receiving service at thesame location for other usages. Service is subject to the established rules and regulations ofthe Cooperative.

    2. TYPE OF SERVICESingle- or three-phase, 60 cycles at available secondary voltage, separately metered.

    3. RATEFacility Charge: $8.50 per month (second meter charge)

    Energy Charge: All energy @ 6.1¢ per kWh (September – May billing periods)Energy Charge: All energy @ 15.0¢ per kWh (June – August billing periods)

    4. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    5. MINIMUM CHARGE

    The minimum monthly charge under above rate shall be the facility charge noted above.

    6. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    7. CONDITIONS OF SERVICEA. The member shall provide the complete service entrance according to the

    Cooperative’s specifications necessary for the separate electric heat meter.

    B. The member shall permanently install and operate electric home heating equipment in

    conjunction with an oil or gas-fired central furnace as approved by this Cooperative. Ifmember wishes to use wood backup or no backup they must supply the Cooperativewith a liability waiver.

    C. The electric service to the electric heat shall be interrupted during peak load periods.

    D. Electric water heaters may not be connected to this service.

    E. Supplemental resistance electric heat in heat pumps may be included on this rate.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    15/34

      14

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes I1H, I4H, J1H,Friendship, Wisconsin J2H, J3H, J4H

    Effective: 01-11-10Rate Schedule: EH-I

    INTERRUPTIBLE - DUAL FUELELECTRIC SPACE HEATING

    Page 2 of 2

    F. Systems that include air conditioning will not be allowed on this rate; however,schedule GS-TOD is available.

    8. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    16/34

      15

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code 34Friendship, Wisconsin Effective: 9/8/14

    Rate Schedule: PS

    COMMERCIAL SERVICE (3ϕ)

    1. AVAILABILITYAvailable to all three-phase accounts (excluding irrigation pumping) requiring less than 50kVA of transformer capacity, or whose measured maximum demand for eleven (11) of the past twelve (12) months has been less than 40 kW. Service is subject to the established rulesand regulations of the Cooperative.

    2. TYPE OF SERVICEThree-phase, 60 cycles at available secondary voltage

    3. RATEFacility Charge: $1.65 per day

    Energy Charge: All energy @ 10.5¢ per kWh

    4. MINIMUM MONTHLY BILLThe facility charge specified above, except where multiple units are served. (See ACECPolicy #11-3)

    5. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    6. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    7. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric service as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    17/34

      16

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code 34TFriendship, Wisconsin Effective: 9/8/14

    Rate Schedule: PS-TOD

    COMMERCIAL SERVICE (3ϕ) TIME-OF-DAY (TOD)

    1. AVAILABILITY

    Available to all three-phase accounts (excluding irrigation pumping) requiring less than 50kVA of transformer capacity, or whose measured maximum demand for eleven (11) of the past twelve (12) months has been less than 40 kW. Service is subject to the established rulesand regulations of the Cooperative.

    2. TYPE OF SERVICEThree-phase, 60 cycles at available secondary voltage

    3. RATEFacility Charge: $1.91 per dayEnergy Charge: On-Peak @ 33.0¢ per kWh

    Off-Peak @ 7.2¢ per kWh

    On-Peak:October 20 - April 20: 5:00 p.m. to 8:00 p.m.

    Monday through Friday, except HolidaysApril 21 – October 19: 1:00 p.m. to 8:00 p.m.

    Monday through Friday, except Holidays

    Off-Peak: All other hours

    4. MINIMUM MONTHLY BILL

    The facility charge specified above, except where multiple units are served.(See ACEC Policy #11-3)

    5. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    6. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    7. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric service as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    18/34

      17

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes 63, 64Friendship, Wisconsin Effective: 01-01-14

    Rate Schedule: LP-1

    LARGE POWER SERVICE

    1. AVAILABILITYFor all single and three-phase non-irrigation accounts;

    A.  Whose measured maximum demands for two (2) or more of the past twelve (12)months has been equal to or greater than 40 kW.

    B.   New accounts whose measured demands are estimated to be 40 kW or more shall be placed on this rate until we have twelve (12) months of historical measureddemand readings.

    C.  For accounts that have twelve (12) consecutive months where the measuredmaximum demand is less than 40 kW the Cooperative may transfer the account tothe GS or PS rate, whichever is appropriate.

    D. 

    This rate is available to any single- or three-phase non-irrigation account of lessthan 40 kW peak demand, at the member’s request.

    E. 

    This rate is not available to accounts requiring 1000 kVA or more of transformercapacity.

    F.  Service is subject to the established rules and regulations of the Cooperative.

    2. TYPE OF SERVICESingle-phase and three-phase, 60 cycles at available secondary voltage.

    3. RATE

    Facility Charge: $65.00 per monthDemand Charge: $18.06 per kW maximum demandEnergy Charge: All kWh @ 4.7¢ per kWh

    4. POWER FACTOR CHARGE – At the Option of the Cooperative20.0¢ per kVAR of maximum monthly reactive demand.

    5. MINIMUM CHARGEThe minimum monthly charge is the facility charge.

    6. DETERMINATION OF BILLING DEMAND

    The billing demand for the month shall be the maximum recorded fifteen (15) minute demandin kilowatts.

    7. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    19/34

      18

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes 63, 64Friendship, Wisconsin Effective: 01-01-14

    Rate Schedule: LP-1

    LARGE POWER SERVICEPage 2 of 2

    8. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    9. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    20/34

      19

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes: ALS, BRK, ENB, FCI,Friendship, Wisconsin GLO, HRT, KOC, MCN, UNI & UWGP

    Effective: 9/8/14Rate Schedule: LP-2

    LARGE POWER SERVICE (OVER 1000 KVA)

    1. AVAILABILITYAvailable to all three-phase accounts requiring 1,000 kVA or more of transformer capacity.Service is subject to the established rules and regulations of the Cooperative.

    2. TYPE OF SERVICEThree-phase, 60 cycles at available secondary voltage

    3. RATEFacility Charge: Based on cost of facilities installed by ACEC on a

     per facility basis.Firm Demand Charge: $21.79 per kW per month, measured at the time of

    ACEC’s power supply coincident peak

    Interruptible Demand Charge: $17.99 (special contract required)

    Energy Charge: On-peak - all kWh @ 4.7¢ per kWhOff-peak - all kWh @ 3.3¢ per kWh

    On-Peak Period: 8 am – 10 pm Monday-Friday, except Holidays

    Off-Peak: All other hours

    4. POWER FACTOR CHARGE - At the option of the Cooperative

    20.0¢ per kVAR of maximum monthly reactive demand.5. MINIMUM CHARGE

    A. The minimum monthly charge is the facility charge.B. The minimum annual charge shall be five (5) times the maximum demand charge

    during the year.

    6. DETERMINATION OF BILLING DEMANDThe billing demand for the month shall be the maximum recorded fifteen (15) minutedemand in kilowatts during the hour of ACEC’s power supply coincident peak.

    7. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour, in accordance with

    changes in the Cooperative’s wholesale power cost, will be added to or deducted from themember’s current bill for electric service as appropriate.

    8. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    9. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    21/34

      20

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code ENB2Friendship, Wisconsin Effective: 2/1/15

    Rate Schedule: LP-ED

    LARGE POWER ECONOMIC DEVELOPMENT (OVER 10,000 KVA)

    1. AVAILABILITYAvailable to all new three-phase accounts requiring 10,000 kVA or more of transformer

    capacity for a period of three years from first billing. Service is subject to the establishedrules and regulations of the Cooperative.

    2. TYPE OF SERVICEThree-phase, 60 cycles at available secondary voltage

    3. RATEFacility Charge: Based on cost of facilities installed by ACEC on a

     per facility basis.

    Firm Demand Charge: $21.79 per kW per month, measured at the time ofACEC’s power supply coincident peak

    Interruptible Demand Charge: $17.99 (special contract required)Energy Charge: On-peak - all kWh @ 4.2¢ per kWh

    Off-peak - all kWh @ 3.0¢ per kWh

    On-Peak Period: 8 am – 10 pm Monday-Friday, except Holidays

    Off-Peak: All other hours

    4. POWER FACTOR CHARGE - At the option of the Cooperative20.0¢ per kVAR of maximum monthly reactive demand.

    5. MINIMUM CHARGE - The minimum monthly charge is the facility charge.

    6. DETERMINATION OF BILLING DEMANDThe billing demand for the month shall be the maximum recorded fifteen (15) minutedemand in kilowatts during the hour of ACEC’s power supply coincident peak.

    7. HIGH LOAD FACTOR CREDITA credit of $0.015 per kWhr will be provided for energy greater than 40% load factor (based onthe maximum 15-minute non-coincident peak demand of that month) in each month

    8. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour, in accordance withchanges in the Cooperative’s wholesale power cost, will be added to or deducted from themember’s current bill for electric service as appropriate.

    9. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    10. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    22/34

      21

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code EBRFriendship, Wisconsin Effective: 01-01-14

    Rate Schedule: LP - TOD

    LARGE POWER SERVICE – TIME-OF-DAY (TOD)

    1. AVAILABILITY

    For all single and three-phase non-irrigation accounts requesting a Time-of-Day rate;A.  Whose measured maximum demands for two (2) or more of the past twelve (12)

    months has been equal to or greater than 40 kW.B.   New accounts whose measured demands are estimated to be 40 kW or more shall

     be placed on this rate until twelve (12) months of historical measured demandreadings are available.

    C.  For accounts that have twelve (12) consecutive months where the measuredmaximum demand is less than 40 kW the Cooperative may transfer the account tothe GS or PS rate, whichever is appropriate.

    D. 

    This rate is not available to accounts requiring 1000 kVA or more of transformercapacity.

    E.  Service is subject to the established rules and regulations of the Cooperative.

    2. TYPE OF SERVICESingle-phase and three-phase 60 cycles at available secondary voltage.

    3. RATEFacility Charge: $81.00 per monthDemand Charge: $21.79 per kW per month on-peak

    $ 8.19 per kW per month off-peak

    Energy Charge: On-peak - all kWh @ 4.95¢ per kWhOff-peak - all kWh @ 3.13¢ per kWh

    On-Peak Period:Oct. 1 – March 31: 5:00 p.m. to 8:00 p.m.

    Monday through Friday, except HolidaysApril 1 – Sept. 30: 10:00 a.m. to 8:00 p.m.

    Monday through Friday, except Holidays

    Off-Peak:All other hours

    4. POWER FACTOR CHARGE – At the option of the Cooperative20.0¢ per kVAR of maximum monthly reactive demand.

    5. MINIMUM CHARGEThe minimum monthly charge is the facility charge.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    23/34

      22

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code EBRFriendship, Wisconsin Effective: 01-01-14

    Rate Schedule: LP - TOD

    LARGE POWER SERVICE – TIME-OF-DAY (TOD)Page 2 of 2

    6. DETERMINATION OF BILLING DEMANDThis shall be the maximum kilowatt demand established for any fifteen (15) consecutiveminutes recorded during the established on-peak period and off-peak period during themonth for which the bill is rendered, as indicated or recorded by a time-of-day demandmeter.

    7. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    8. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late paymentcharge on the unpaid balance in accordance with the Cooperative’s Service Rules &Regulations.

    9. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, andany other legislative or regulatory fees imposed by governmental agencies will be appliedto each billing for electric services as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    24/34

      23

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes M6, M66Friendship, Wisconsin 53934 Effective: 4/1/16

    Rate Schedule: I-1

    IRRIGATION SERVICE - NO ACEC CONTROL

    1. AVAILABILITYFor all services serving irrigation pumps 15 HP and over, subject to the established rules andregulations of the Cooperative including requirements for load management controls.

    2. TYPE OF SERVICEThree-phase three-wire, three-phase four-wire, and single-phase, at available secondaryvoltages.

    3. RATEFacility Charge: $1,200 per year @ $100 per month for 12 months OR $200 per

    month April through September.

    Demand Charges: $33.00per kW maximum demand billed April through September

    Energy Charges: All energy @ 3.8¢ per kWh

    4. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    5. MINIMUM ANNUAL CHARGE

    A. 

    The minimum annual charge shall be the facility charge.

    B.  Where a system or land is leased and credit with the Cooperative has not beenestablished, a deposit equivalent to $25.00/kW of established demand shall be paid inadvance and applied to the October bill or refunded at the end of the season.

    The maximum demand used by the system for prior years is to be used for this charge;otherwise 80% of the installed horsepower will be considered the demand in kW.

    C.  Any balance due on the annual facility charge will be applied to the final bill if serviceis discontinued prior to the end of the billing year.

    6. POWER FACTORThe member agrees to maintain unity power factor as nearly as practicable. Power factorsmay be measured at any time. Should such measurements indicate that the power factor atthe time of the member’s maximum demand is less than 85%, the demand for billing purposes shall be the demand as indicated or recorded by the demand meter, multiplied by85%, and divided by the percent power factor.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    25/34

      24

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes M6, M66Friendship, Wisconsin 53934 Effective: 01-01-14

    Rate Schedule: I-1

    IRRIGATION SERVICE – NO ACEC CONTROLPage 2 of 2

    7. BILLING YEAR AND COMBINED READINGSThe billing year shall start with the March meter reading each year. The registered kilowatt-hour usage from the September meter reading (approximately Sept 30) to the March meterreading (approximately March 31) shall be billed as a single usage for this period except inthe case of cranberry marshes and where facilities other than irrigation pumps are used. Inthese cases, billing will continue throughout the year under the terms and conditions of thisrate. Facility charges shall be billed each month, or if the member chooses the facility chargecan be billed over six billing periods from April through September. In the case of cranberrymarshes and where facilities other than irrigation pumps are used, facility charges shall be billed each month from April through March. Demand charges shall be billed whenever a

    demand of 10 kW or more is recorded, except as noted herein.

    8. MAXIMUM DEMANDThe maximum demand shall be the maximum kilowatt demand (subject to power factoradjustment) established for any period of fifteen (15) consecutive minutes during the monthfor which the bill is rendered as indicated or recorded by a demand meter.

    9. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    10. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be added to eachmonthly bill for electric service as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    26/34

      25

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes MC6, MC66Friendship, Wisconsin 53934 Effective: 4/1/16

    Rate Schedule: I-2

    IRRIGATION SERVICE NO ACEC CONTROL - COINCIDENT

    1. AVAILABILITY – EXPERIMENTAL RATE ONLY – NOT OPEN

    For all services serving irrigation pumps 15 HP and over, subject to the established rules andregulations of the Cooperative including requirements for load management controls.

    2. TYPE OF SERVICEThree-phase three-wire, three-phase four-wire, and single-phase, at available secondaryvoltages.

    3. RATEFacility Charge: $1,200 per year @ $100 per month for 12 months OR $200 per

    month April through September.

    Demand Charges: $21.79 per kW demand billed April through September measuredat the time of ACEC’s power supply coincident peak, and$8.70 per kW maximum demand billed April through Septemberfor distribution

    Energy Charges: All energy @ 3.8¢ per kWh

    4. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance withchanges in the Cooperative’s wholesale power cost will be added to or deducted from themember’s current bill for electric service as appropriate.

    5. MINIMUM ANNUAL CHARGEA.  The minimum annual charge shall be the facility charge.

    B.  Where a system or land is leased and credit with the Cooperative has not beenestablished, a deposit equivalent to $25.00/kW of established demand shall be paid inadvance and applied to the October bill or refunded at the end of the season.

    The maximum demand used by the system for prior years is to be used for this charge;otherwise 80% of the installed horsepower will be considered the demand in kW.

    C.  Any balance due on the annual facility charge will be applied to the final bill if service

    is discontinued prior to the end of the billing year.

    6. POWER FACTORThe member agrees to maintain unity power factor as nearly as practicable. Power factorsmay be measured at any time. Should such measurements indicate that the power factor atthe time of the member’s maximum demand is less than 85%, the demand for billing purposes shall be the demand as indicated or recorded by the demand meter, multiplied by85%, and divided by the percent power factor.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    27/34

      26

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes MC6, MC66Friendship, Wisconsin 53934 Effective: 01-01-14

    Rate Schedule: I-2

    IRRIGATION SERVICE NO ACEC CONTROL - COINCIDENTPage 2 of 2

    7. BILLING YEAR AND COMBINED READINGSThe billing year shall start with the March meter reading each year. The registered kilowatt-hour usage from the September meter reading (approximately Sept 30) to the March meterreading (approximately March 31) shall be billed as a single usage for this period except inthe case of cranberry marshes and where facilities other than irrigation pumps are used. Inthese cases, billing will continue throughout the year under the terms and conditions of thisrate. Facility charges shall be billed each month, or if the member chooses the facility chargecan be billed over six billing periods from April through September. In the case of cranberrymarshes and where facilities other than irrigation pumps are used, facility charges shall be billed each month from April through March. Demand charges shall be billed whenever a

    demand of 10 kW or more is recorded, except as noted herein.

    8. DETERMINATION OF BILLING DEMANDSThe power supply portion of the billing demand for the month shall be the average of thefour fifteen (15) minute demands in kilowatts during the hour of ACEC’s power supplycoincident peak and the distribution portion of the billing demand shall be the maximumkilowatt demand established for any period of fifteen (15) consecutive minutes during themonth for which the bill is rendered, as indicated or recorded by a demand meter. Bothdemands are subject to power factor adjustment.

    9. TERMS OF PAYMENT

    The above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    10. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be added to eachmonthly bill for electric service as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    28/34

      27

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes N6, N66, P6, P66Friendship, Wisconsin 53934 Effective: 4/1/16

    Rate Schedule: I-3

    IRRIGATION SERVICE OFF PEAK – ACEC CONTROLLED

    1. AVAILABILITYFor all services serving irrigation pumps 15 HP and over, subject to the established rules andregulations of the Cooperative including requirements for load management controls.

    2. TYPE OF SERVICEThree-phase three-wire, three-phase four wire, and single-phase, at available secondaryvoltages.

    3. RATEFacility Charge: $1,200 per year @ $100 per month for 12 months, OR $200 per

    month April through September.

    Demand Charges: $8.70/per kW billed April through September for distribution.Energy Charges: All energy @ 3.8¢ per kWh

    4. CONDITIONS OF SERVICEService shall be available during off-peak hours only.Off-peak hours are as follows: Monday through Friday, 8:00 p.m. to 8:00 a.m.,

    and all hours on Saturday, Sunday and Holidays.

    5. POWER COST ADJUSTMENT CHARGEAny adjustment in the Cooperative’s energy cost per kilowatt-hour, in accordance with thechanges in the Cooperative’s wholesale power cost, will be added to or deducted

    from the member’s current bill for electric service as appropriate.

    6. MINIMUM ANNUAL CHARGEA. The minimum annual charge shall be the facility charge.

    B. Where a system or land is leased, and credit with the Cooperative has not beenestablished, a deposit equivalent to $25.00/kW of established demand shall be paid inadvance and applied to the October bill or refunded at the end of the season. .

    The maximum demand used by the system for prior years is to be used for this charge;otherwise 80% of the installed horsepower will be considered the demand in kW.

    C. Any balance due on the annual facility charge will be applied to the final bill if service isdiscontinued prior to the end of the billing year.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    29/34

      28

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes N6, N66, P6, P66Friendship, Wisconsin 53934 Effective: 4/1/16

    Rate Schedule: I-3

    IRRIGATION SERVICE RATE – ACEC CONTROLLEDPage 2 of 2

    7. POWER FACTORThe member agrees to maintain unity power factor as nearly as practicable. Power factorsmay be measured at any time. Should such measurements indicate that the power factor atthe time of the member’s maximum demand is less than 85%, the demand for billing purposes shall be the demand as indicated or recorded by the demand meter, multiplied by85%, and divided by the percent power factor.

    8. BILLING YEAR AND COMBINED READINGSThe billing year shall start with the March meter reading each year. The registered kilowatt-hour usage from the October meter reading (approximately Oct 30) to the March meterreading (approximately March 31) shall be billed as a single usage for this period except in

    the case of cranberry marshes and where facilities other than irrigation pumps are used. Inthese cases, billing will continue throughout the year under the terms and conditions of thisrate. Facility charges shall be billed each month, or if the member chooses the facility chargecan be billed over six billing periods from April through September. In the case of cranberrymarshes and where facilities other than irrigation pumps are used, facility charges shall be billed each month from April through March. Demand charges shall be billed whenever ademand of 10 kW or more is recorded, except as noted herein.

    9. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    10. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be added to eachmonthly bill for electric service as applicable.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    30/34

      29

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code: YLFriendship, Wisconsin Effective: 9/8/14

    Rate Schedule: YL

    YARD LIGHT RENTAL FACILITIES

    1. AVAILABILITYAvailable for all members on a monthly basis upon acceptance by the Cooperative of asigned Yard Light Lease Agreement. Service is subject to the established rules andregulations of the Cooperative.

    2. RATEA. $11.00 per month for a lamp controlled with an electric eye and installed on an existingCooperative pole.

    B. Other charges and conditions according to the Cooperative’s Service Rules & Regulationsi.  An additional monthly charge will be applied for a pole set solely for the yard

    light ($0.75 – 30’ pole, $1.00 – 35’ pole).ii.  Service over 100 feet will be installed at an additional monthly charge for each

    50-foot increment ($0.50 per extra 50 feet).iii.  An additional monthly charge shall be made where secondary voltage is not

    available and a transformer must be provided ($8.00).iv.   Non-standard units (i.e., longer pole or mast arm) may be installed at additional

    cost ($0.50 – 6-10’ arm, $1.00 – 12-16’ arm, $1.00 – secondary ped).v.  Charges for unusual services such as road bores, secondary pedestals, primary

    (12.5kV) facilities, tree trimming, star gazer shield or guy wires will be billed upfront on a case-by-case basis.

    vi.  Lights are installed on the ACEC side of the meter only. Energy charges are

    included in the base rate.

    3. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    4. TERMS OF CONTRACTThree-year minimum, unless otherwise specified.

    5. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any

    other legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

    6. REFERENCEYard Light Lease Agreement - ACEC Form 3.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    31/34

      30

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code: SLFriendship, Wisconsin Effective: 9/8/14

    Rate Schedule: SL

    STREET LIGHT RENTAL FACILITIES

    1. AVAILABILITYAvailable for townships, unincorporated municipalities and select members on a monthly

     basis upon acceptance by the Cooperative of a signed Street Light Lease Agreement. Serviceis subject to the established rules and regulations of the Cooperative.

    2. RATEA. All street lights will have lamps controlled with an electric eye and installed on an

    existing Cooperative pole.100 watt $11.00 per month150 watt $11.75 per month250 watt $12.75 per month400 watt $17.75 per month

    B. Other charges and conditions according to the Cooperative’s Service Rules & Regulationsi. 

    An additional monthly charge will be applied for a pole set solely for the streetlight ($0.75 – 30’ pole, $1.00 – 35’ pole).

    ii.  Service over 100 feet will be installed at an additional monthly charge ($0.50 perextra 50 feet).

    iii.  An additional monthly charge shall be made where secondary voltage is notavailable and a transformer must be provided ($8.00).

    iv.   Non-standard units (i.e., longer pole or mast arm) may be installed at additionalcost ($0.50 – 6-10’ arm, $1.00 – 12-16’ arm, $1.00 – secondary ped).

    v.  Charges for unusual services such as road bores, secondary pedestals, primary(12.5kV) facilities, tree trimming, star gazer shield or guy wires will be billed upfront on a case-by-case basis.

    vi. 

    Lights are installed on the ACEC side of the meter only. Energy charges areincluded in the base rate.

    vii.  A reconnect fee will be charged for connecting or replacing lights that have beendisconnected or removed during the preceding twelve (12) months.

    3. TERMS OF PAYMENTThe above rates are net. Bills not paid by the due date are subject to a late payment chargeon the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.

    4. TERMS OF CONTRACTThree-year minimum, unless otherwise specified.

    5. TAXES AND FEESThe State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and anyother legislative or regulatory fees imposed by governmental agencies will be applied to each billing for electric services as applicable.

    6. REFERENCEStreet Light Lease Agreement - ACEC Form 314

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    32/34

      31

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes RGS21, RGS23, RGS42Friendship, WI 53934 Effective: 4/1/16

    Rate Schedule: RGS

    RENEWABLE GENERATION RATE – CLOSED RATE

    1. AVAILABILITYThis rate is closed. No new connects will be allowed under this rate; existing accounts may

    remain under this rate until 3/31/26. See rate schedule RG. A member under this rate maytransfer to rate schedule RG at any time but may not return to this rate.

    2. SERVICE CHARACTERISTICSAlternating current, 60 Hertz at available voltages and standards of the Cooperative.

    3. MONTHLY SALES RATEThe facility charge and energy rate for sales to the member shall be in accordance with therate schedule applicable to the class of service provided.

    4. MONTHLY PURCHASE RATE – SMALL DISTRIBUTED RENEWABLES (S)Total generating capacity not to exceed 20kW single-phase or three-phase.

     Net energy billing may be used with reverse registration permitted - direct metering only.The following rate shall apply when member generation exceeds use:

    Energy Credit (payment to member): Shall be in accordance with the rate the member ischarged for the connected service. For generation connected to residential services thegeneral service rate schedule (GS) would apply.

    5. FACILITY CHARGEIf a second meter or special metering is required to properly register renewable generation afacility charge not less than the standard second meter charge, but sufficient to cover costswill be applied.

    6. TERMS OF PAYMENTPayment of the fixed charge and for sales to the member will be in accordance with the rateschedule applicable to the class of service provided. Payment to the member for sales to theCooperative will be made separately within fifteen (15) days after the closing of each month;except the Cooperative may credit payment for purchases against any past due amounts owedthe Cooperative

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    33/34

      32

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code RGL23, RGL64Friendship, WI 53934 Effective: 4/1/16

    Rate Schedule: RGL

    RENEWABLE GENERATION RATE – CLOSED RATE

    1. AVAILABILITYThis rate is closed. No new connects will be allowed under this rate; existing accounts may

    remain under this rate until 3/31/26. See rate schedule RG. A member under this rate maytransfer to rate schedule RG at any time but may not return to this rate.

    2. SERVICE CHARACTERISTICSAlternating current, 60 Hertz at available voltages and standards of the Cooperative.

    3. MONTHLY SALES RATEThe energy rate for sales to the member shall be in accordance with the rate scheduleapplicable to the class of service provided.

    4. MONTHLY PURCHASE RATE – LARGE DISTRIBUTED RENEWABLES (L)Total generating capacity greater than 20kW.

    The following rate shall apply when member generation exceeds use:Energy Credit (payment to member): Generation supply cost

    Capacity Credit (payment to member meeting qualification): LP-2 demand charge(coincident) 

    5. FACILITY CHARGEAny interconnection and special metering costs not paid as aid-to-construction will berecovered through a facility charge sufficient to cover Cooperative’s costs.

    6. CAPACITY CREDIT QUALIFICATIONThe monthly capacity factor of the member’s generator exceeds 70% during the Cooperative power supplier on-peak energy periods over each of the prior 12 months.

    7. TERMS OF PAYMENTPayment of the fixed charge and for sales to the member will be in accordance with the rateschedule applicable to the class of service provided. Payment to the member for sales to theCooperative will be made separately within fifteen (15) days after the closing of each month;except the Cooperative may credit payment for purchases against any past due amounts owedthe Cooperative.

  • 8/18/2019 Adams-Columbia - 2016 Rate Book

    34/34

    ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes RG21, RG23, RG42, RG64Friendship, WI 53934 Effective: 4/1/16

    Rate Schedule: RG

    RENEWABLE GENERATION RATE

    1. AVAILABILITYAvailable to all members with qualified renewable energy conversion system facilities

    connected in parallel with the Cooperative’s electric system.

    2. SERVICE CHARACTERISTICSAlternating current, 60 Hertz at available voltages and standards of the Cooperative.

    3. MONTHLY RATE FOR SALES TO MEMBER

    Facility Charge See below (for first meter on site)See below (for second meter on site)

    Power Supply Demand Charge: $21.79 per kW per month, measured for the hour ofACEC’s power supply coincident peak

    Distribution Demand Charge: $6.70 per kW per month of measured maximumhourly demand.

    Energy Charge: On-peak - all kWh @ 4.7¢ per kWhOff-peak - all kWh @ 3.3¢ per kWh

    4. MONTHLY PURCHASE RATEThe following rates shall apply when member supplies renewable generation to ACEC:

    Facility Charge: See belowPower Supply Capacity (Credit): $21.79 per kW per month, measured for the hour of

    ACEC’s power supply coincident peakDistribution Capacity (Credit): $6.70 per kW per month of measured hourly demand

    at the time ACEC’s distribution system peaks for

    kW amount consistently available (currently 0 for solar).Energy (Credit): On-peak - all kWh @ 4.7¢ per kWh

    Off-peak - all kWh @ 3.3¢ per kWh

    5. FACILITY CHARGEA two meter installation will typically be required (when member has load to be served that isseparate from the requirements of the generation facility such as for a home or other buildingon the property). If the member has only one meter at the energy conversion system service point, however, the facility charge shall be the same as the first meter charge for theresidential rate class, unless such metering is insufficient and commercial service metering isrequired, in which case the facility charge will be equal to the commercial or large power rate

    class, as appropriate. When a second meter is used at a member location it shall be used forthe generation facility, and the facility charge for the second meter will be not less than thestandard second meter charge, but sufficient to cover the Cooperative’s costs.