acutus medical product catalog• braided shaft — improved torque response and stability •...
TRANSCRIPT
Acutus MedicalProduct Catalog
KEY ATTRIBUTES•Navigation,2Drecording,Anatomy,3DMapping
•AnatomyreconstructionacquiredusingM-modeultrasound
•Visualizepatternsbeyondfocalandrotation—Locatenon-PVtargets
•Fullchambermappingofbothstableandunstablerhythms
•Quicklyremaptoassessablationeffectiveness,diagnosenewarrhythmias
ORDER NUMBER DESCRIPTION900100 AcQMapHighResolutionImagingandMappingSystem
AcQMapSystemincludesthefollowingcomponents:
ORDER NUMBER DESCRIPTION800500 AcQMapConsole
800520 AcQMapWorkstation800422 AcQMapAuxiliaryInterfaceBox
800522 AcQMapECGOutw/SnapsCable
800524 AcQMapECGPOSTCable
800523 AcQMap2mmPinJumperSet
800510 AdapterCable,AcQMap→AblationCatheter
800511 MaestroAdapterCable,AcQMap→Maestro
ORDER NUMBER DESCRIPTION800255 AcQMapWorkstationCable800421 AcQMapECGInputCable
800424 AcQMapECGOutputCable
800505 AcQMapAblationReferenceCable
800508 AcQMapAblationElectrogramCable
800431 AcQMap→AbbottAmpereAblationCatheterAdapterCable
800430 AcQMap→AbbottAmpereRFGeneratorAdapterCable
TheAcQMapsystemisastand-aloneEPmappingplatformthathastheuniqueabilitytocreatecardiacanatomyutilizingultrasoundandprovidefullchamberultra-highresolution,real-time3Dmapsofstableandunstableatrialarrythmias.
GENERATOR CABLE 1 CABLE 2 CABLE 3 CABLE 4Stockert BiosenseWebster N/A N/A BiosenseWebsterSmartAblate BiosenseWebster N/A N/A BiosenseWebsterAbbottAmpere St.Jude/Abbott 800431 800430 St.Jude/AbbottMaestro BostonScientific 800510 800511 BostonScientific
FRONT
PATIENT RETURN*
ORDER NUMBER USED WITH DESCRIPTION CONTENTS (PER KIT)800365-002or800365-004(Boxof5)
AcQMapSystem900000 AcQMapPatientElectrodeKit 6-LocalizationDispersiveElectrodes1-PatientReturnElectrode15-RepositionableMonitoringElectrodes
800365-003(Boxof5)
AcQMapSystem900100 AcQMapPatientElectrodeKit 6-LocalizationDispersiveElectrodes1-PatientReturnElectrode15-RepositionableMonitoringElectrodes
RIGHT SIDE FRONT LEFT SIDEBACK
TheAcQMap3DImagingandMappingCatheterisanadvanced,non-contact,intracardiaccatheterusedformappingtheatrialsubstrate.
SIDES
BACK
TheAcQMapPatientElectrodeKitiscompatiblewiththeAcQMapHighResolution3DImagingandMappingSystem.
*Used with Model 900100
ORDER NUMBER DESCRIPTION USABLE LENGTH
DEPLOYED DIAMETER
GUIDEWIRE COMPATIBILITY
NUMBER OF ELECTRODES
NUMBER OF ULTRASOUND TRANSDUCERS
900003 AcQMap3DImagingandMappingCatheter
100cm 25mm 0.032in 48 48
48HighFidelityLowImpedanceElectrodes
25mmDiameter 0.032”(0.81mm)
GuidewireCompatible
48UltrasoundTransducers
KEY ATTRIBUTES•Unidirectionalsteeringwith0-180degreedeflection
•Braidedshaft—improvedtorqueresponseandstability
•Atraumatictip—seamlesstransitionintovasculatureandseptalcrossing
ORDER NUMBER DESCRIPTION I.D. O.D. DILATOR GUIDEWIRE COMPATIBILITY
WORKING LENGTH
OVERALL LENGTH
900002 AcQGuideSteerableSheath 12.8F 16F 0.035in 75cm 95.5cm
ORDER NUMBER DESCRIPTION I.D. O.D. DILATOR GUIDEWIRE COMPATIBILITY
WORKING LENGTH
OVERALL LENGTH
900005 AcQRefIntroducerSheath 7F 10.8F 0.038in 30cm 34cm
KEY ATTRIBUTES•VascularaccessforAuxiliaryEPcatheters(7F)
•Stableelectricalreference
AcQRefisadual-purposeintroducersheathwithintegratedelectrodesthatprovidesstableelectricalreferenceandeliminatestheneedforanadditionalintroducerandquadrapolarreferencecatheter.
TheAcQGuidesheathprovidesoptimalmaneuverabilityandincreasedcontrol,providingastableplatformtoensuresmoothcatheterpassageandprecisionplacement.
MM-022 Rev. D
ACUTUS MEDICAL, INC. 2210FaradayAveSuite100Carlsbad,CA92008UnitedStatesTel:+1-442-232-6080 AcutusMedical,theAcutusMedicallogo,AcQGuide,
AcQRefandAcQMapareregisteredtrademarksofAcutusMedical,Inc.ThismaterialisthepropertyofAcutusMedicalanditssubsidiaries.Pleasedonotcopy,forward,ordistributethisdocument.Copyright©2019AcutusMedical,Inc.Allrightsreserved.
For more information please contact your Acutus Medical representative:
For further information regarding Acutus Medical and its products, please visit acutusmedical.com
Priortousingthesedevices,pleasereviewtheinstructionsforuseforacompletelistingofindications,contraindications,warnings,precautions,potentialadverseeventsanddirectionsforuse.TheAcQMap,AcQGuideandAcQRefdevicesareCEMarkedandFDAcleared.