acquity systems with 2d technology - waters …acquity systems with 2d technology ©2012 waters...

25
©2012 Waters Corporation 1 ACQUITY Systems with 2D Technology MS Technology Day Sesión Alimentación y Medio Ambiente Barcelona, 21 de marzo de 2012

Upload: others

Post on 31-May-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 1

ACQUITY Systems with 2D Technology

MS Technology Day

Sesión Alimentación y Medio Ambiente

Barcelona, 21 de marzo de 2012

Page 2: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 2

Why Bother with 2D Chromatography?

Page 3: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 3

Two Dimensional Chromatography Principal

2.1

2.2

Separation Method #1

1

2

Separation Method #2

1.1

1.2

Page 4: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 4

ACQUITY UPLC Systems with 2D Technology Solves Four Key Customer Challenges

Increase Selectivity & Sensitivity

Eliminate Unwanted

Interferences

Mobile Phase Flexibility

Characterize the Most Complex Samples

Page 5: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 5

Agenda

Waters Two Dimensional UPLC Capability

Two Dimensional Functions and Analytical Benefits — Trapping

— Heart Cutting

— Parallel Column Regeneration

— At-Column Dilution

Page 6: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 6

Simple to Use Easy to Implement Proven UPLC benefits

—Resolution —Sensitivity —Productivity

Compatible with a wide range of Chemistries

ACQUITY Systems with 2D Technology

Page 7: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 7

ACQUITY UPLC Column Manager Designed for 2D Operation

Two Easy-to-access, 6-port 2-position valves Two independent temperature controlled zones Low Volume Active Pre-Heaters Ensure best

Chromatographic performance run to run and system to system

Page 8: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 8

ACQUITY Systems with 2D Technology Software Control through MassLynx

Binary Solvent Manager Quaternary Solvent Manager

Page 9: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 9

ACQUITY Systems with 2D Technology Software Control through MassLynx

Simple Control of Valves by Timed Events in Column Manager

Page 10: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 10

Trapping

Page 11: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 15

Time 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 5.20 5.40

%

0

100

MRM of 6 Channels ES+ 327 > 269.9

1.46e6 4.31

250 uL Clozapine 1 ppb 2D – 3 min gradient

250 uL Clozapine 1 ppb 1D – 3 min gradient

Peak distortion Volume Overload

20 uL Clozapine 1 ppb 1D – 3 min gradient

Increase Sample Loading and Sensitivity with Trap and Transfer Configuration

Page 12: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 16

Heart Cutting

Page 13: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 17

ACQUITY UPLC and Xevo TQ MS Bioanalysis

1D Separation

Page 14: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 18

Running 1D

1

BSM 1 +SM

BSM 2

Waste

1D column

BSM2

2D column

Trapping Column

Page 15: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 21

Heart Cutting– ACQUITY UPLC with 2D Technology and Xevo TQ MS

1D Separation

2D Separation

Page 16: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 22

ACQUITY UPLC with 2D Technology – Impurity Profiling Heart Cut

Heart Cut

Page 17: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 23

2D Heart-cutting Benefits

Orthogonality

— In mathematics, two vectors are orthogonal if they are perpendicular, i.e., they form a right angle. The word comes from the Greek ὀρθός (orthos), meaning "straight", and γωνία (gonia), meaning "angle". For example, a subway and the street above, although they do not physically intersect, are orthogonal if they cross at a right angle.

Specificity of a method

Enhanced sensitivity in MS by dramatic reduction of matrix effect.

Possibility to load more and refocused the 1D into the 2D

Page 18: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 24

1D Chromatogram

Connect Waste tubing to MS

Leave the valve in position 1 to see the 1D peak eluting

This is the 1D peak we will have to trap

Page 19: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 25

Separation is performed on the 2D column

Page 20: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 26

2D on the Xevo TQ-S 5pg/ml Plasma Estradiol

Page 21: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 27

1D vs 2D

1D

2D

Page 22: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 28

Parallel Column Regeneration

Page 23: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 29

Parallel Column Regeneration

Increase Overall Speed of Analysis — Analytical Separation Performed while 2nd Column is Regenerated

Page 24: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 30

Parallel Column Regeneration Case Study

Complex Samples Requiring Long Run times of 35 minutes

Regeneration and Requilibration requiring 15 minutes

24 Hour Operation Samples Run 1 Dimensional ACQUITY UPLC 28 ACQUITY UPLC with 2D Technology 41

30% Increase in Throughput

Page 25: ACQUITY Systems with 2D Technology - Waters …ACQUITY Systems with 2D Technology ©2012 Waters Corporation 7 ACQUITY UPLC Column Manager Designed for 2D Operation Two Easy-to-access,

©2012 Waters Corporation 37

Summary – ACQUITY Systems with 2D Technology

Simple to Use

Easy to Implement

Straightforward to operate in various 2D functions — Trapping

— Heart Cutting

— Parallel Column Regeneration

— At-Column Dilution