aco & pco ion procedure
TRANSCRIPT
-
8/6/2019 ACO & PCO ion Procedure
1/14
OPTIMISATION PROCEDURE FOR ACO & PCO
-
8/6/2019 ACO & PCO ion Procedure
2/14
ACCESS CHANNEL OCCUPANCY
-
8/6/2019 ACO & PCO ion Procedure
3/14
Quick Reference Guide for ACO
Reference Reports:
Lucent:- ACO-PCO Summary-Flux / RFISS
Did the sectors
ACO exceed
the threshold in
last months
TOP6 ACO
report?
ACO Thresholds:
Lucent ACO Th = 20%
Yes
It could be due to
special event
or unplanned event,
Keep an eye on occupancy
No
Ensure
Correct Datafill for
all ACH
related Parameters
Process B (Capacity Balancing)
Are the Zone
base
Registrations
High?
Process C ( Zone Base Registration Issue)Yes
Optimization
Yes
Escalate Issue to next level of Support
Prior to R21, Introduce new carrier
With R21, activate new access channel
-
8/6/2019 ACO & PCO ion Procedure
4/14
ACH Recommended Parameter Settings and OMs
Rel28_AccParameters
Rel28_ACP_PCO
-
8/6/2019 ACO & PCO ion Procedure
5/14
NoPhysical
optimization
to control
energy
Yes
Is the
RF energy
overshooting
across the
Zone border?
Process C Zone based
Registration Issues
Are the Zone
settings correct andzones balanced?
No C2 Fix data errors,
Modify LAs usingZone boundary tool.
Yes
C1
Monitor
Stats
ACO
Resolved?
Yes
Done
No
Monitor
StatsACO
Resolved? Done
C4
Optimization
Modify tot_zones and
Zone timer (Cell2)
C3Yes Is the
RF Energy still
overshooting?
C5
Monitor
Stats
Does the
traffic distribution
along the border4 allow
for a zone change?
C8
C6
Yes
ACO
Resolved?
Yes
No
No
Move site tonext zone,
Modify LA.
C7
Monitor
Stats
ACO
Resolved?
Done
Yes
No
Add access channel.
Monitor ACO of all access
Channels (cpcarr 247-250)
C9
Yes
No
No
Process C
Zone BasedRegistrationIssues
-
8/6/2019 ACO & PCO ion Procedure
6/14
Process B
Do all carriers have
same footprint and
sectors loadbalanced within
15%?
Process B - Capacity
Balancing
Are the carriers
balanced within 15%of the average carrier
load?
No
Modify TCA weights, NL,
and IFHO settings
Yes
Conduct Antenna and
Power audits & matchthe footprints and load.
No
Monitor
Stats
ACO Resolved?
Yes
Done
No
Monitor
Stats
ACO Resolved?
Yes
Done
Optimization
Check the next step i.e.Zone Based Registration
No
Yes
CapacityBalancing
-
8/6/2019 ACO & PCO ion Procedure
7/14
PAGING CHANNEL OCCUPANCY
-
8/6/2019 ACO & PCO ion Procedure
8/14
Quick Reference Guide for PCO Lucent
Reference Reports:
Lucent- Monthly Top 6 PCO Report-Falcon /
31 day trending report / RFSM
Prospect
Did the sectors
PCO exceed
the threshold in
last months
TOP6 PCO
report?
PCO Thresholds:
Lucent PCO Threshold = 72%
Yes
(Carrier Balancing) essentially a
common carrier sanity check to
ensure that the PCO is equally
distributed among all reasonable
carriers on the sector
PCO
Resolved
?
No
It could be due to
special event
or unplanned event,
Keep an eye on occupancy
No
Ensure Correct
Data fill for all PCO
impacting
Parameters including
Paging Channel
Overload Controls
Verify if SHAPCAR is enabled in the
switch. Implement sub-MSC paging.
Zone Based Paging & Multiple Paging Channel Analysis
Process A
Yes
Activate 2nd
paging
Channels &
Monitor PCO
Pg. Succ.
improved?
Yes
No
DONE
A
DONE
Add 2nd Pg.
Ch to All sites
In LA/switch/
Adj. SW.?
Add 2nd Carrier
to LA. Optimize LA.
-
8/6/2019 ACO & PCO ion Procedure
9/14
PCH Recommended Parameter Settings and OMs
Attached is the list of all Paging Channel related parameters and the PSP
recommended Standardized settings. The second spreadsheet lists OMs as
of Release 29.
Please verify that each of these parameters are set correctly and ensure
all Fax flashes to optimize the PCH related parameters have been
implemented.
A ccCh_ PgCh_Par ms Rel28_A CP_P CO
-
8/6/2019 ACO & PCO ion Procedure
10/14
Process A
Process A
Implement Sub-MSC paging.
Implement ISPAGE2, as needed. Do
Not Degrade Pg. Success Rate.
Is the ACO on
the zone border
sites < 20% ?
Yes
No
Implement the ACO Resolution Process
Reference Reports:
Page Success Reports:
(i) RFISS Excel Stats Data retrieval
Generic Report.
(ii) Flux
(III) RFSM
Page Channel Occupancy Reports:
(i)RFISS
(ii) Flux
(iii) RFSM
PCO
Resolved ?
Optimize Borders. Optimize LA sizes.
Optimize paging strategy. Do not
degrade Pg. Success rate.
PCO
Resolved ?
Implement CLAC paging. Add access
channels as needed. Do not degrade
Pg. Success Rate.
PCO
Resolved ?DONE
DONE
DONE
Add 2nd Pg. channel. Optimize zones
and paging strategy. Monitor stats
(cpcarr 240-246).
No
No
Enough
Power for 2nd
Pg. Ch.?
Add Carrier/s.
Pg. Success
Degraded?DONE
No
No
No
No
A
Yes
Yes
Yes
-
8/6/2019 ACO & PCO ion Procedure
11/14
Second Paging Channel This feature introduces the ability to support up to 2 Paging
Channels per carrier-sector. Each Paging Channel can accommodate up to six
additional access channels Changing the number of Paging Channels is recommended
to be performed during the maintenancewindow only.
MOP:
note: Deployment of this feature must be closely analyzed
and monitored due to potential loss of capacity due
to limited forward power availability.
2nd_PgCh_MOP
-
8/6/2019 ACO & PCO ion Procedure
12/14
Second Paging Channel: BTSEQP Form View
-
8/6/2019 ACO & PCO ion Procedure
13/14
ACCESS FAILURE REASONS
-
8/6/2019 ACO & PCO ion Procedure
14/14
THANK YOU