aceee 2012
DESCRIPTION
My Presentation to the ACEE2012 Hot Water Forum. I love the message of this group and the work they do.TRANSCRIPT
![Page 1: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/1.jpg)
Eric Larson
Indirect Water End Use Sensing:Consumption, Disaggregation, and Feedback
UNIVERSITY ofWASHINGTON
![Page 2: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/2.jpg)
2 years ago…
![Page 3: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/3.jpg)
• single, screw-on sensor
• senses pressure in real time
hydrosense
Froehlich et al., UbiComp2009; Larson et al., PMC2010, Larson and Froehlich et al. Pervasive 2011
![Page 4: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/4.jpg)
water tower
pressure regulator
water tower
utility water meter
pressure regulator
incoming cold water from supply line
![Page 5: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/5.jpg)
water tower
pressure regulator
water tower
utility water meter
pressure regulator
incoming cold water from supply line
![Page 6: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/6.jpg)
water tower
plumbing layout
water tower
incoming cold water from supply line
utility water meter
pressure regulator
![Page 7: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/7.jpg)
water towerwater tower
thermal expansion
tank
hosespigot
utility water meter
pressure regulator
laundry
bathroom 1
hot water heater bathroom 2
dishwasher
incoming cold water from supply line
kitchen
![Page 8: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/8.jpg)
water towerwater tower
hosespigot
utility water meter
pressure regulator
laundry
bathroom 1
hot water heater bathroom 2
dishwasher
incoming cold water from supply line
toilet flushed
toilet
kitchen
thermal expansion
tank
![Page 9: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/9.jpg)
water towerwater tower
hosespigot
utility water meter
pressure regulator
laundry
bathroom 1
hot water heater bathroom 2
kitchen
dishwasher
incoming cold water from supply line
toilet
kitchen sink cold open
kitchen sink cold
thermal expansion
tank
![Page 10: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/10.jpg)
water towerwater tower
hosespigot
utility water meter
pressure regulator
laundry
bathroom 1
hot water heater bathroom 2
kitchen
dishwasher
incoming cold water from supply line
toilet
kitchen sink hot open
kitchen sink cold
kitchen sink hot
thermal expansion
tank
![Page 11: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/11.jpg)
water towerwater tower
hosespigot
utility water meter
pressure regulator
laundry
bathroom 1
hot water heater bathroom 2
kitchen
dishwasher
incoming cold water from supply line
kitchen sink hot open
thermal expansion
tank
![Page 12: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/12.jpg)
water towerwater tower
hosespigot
utility water meter
pressure regulator
laundry
bathroom 1
hot water heater bathroom 2
kitchen
dishwasher
incoming cold water from supply line
![Page 13: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/13.jpg)
Where are we now?
2 years ago…
•End Use: 10 homes, staged
•Water flow: 7 fixtures, max flow
•Not in real time: no feedback
natural
41
with
All ranges
![Page 14: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/14.jpg)
water end use
water flowfeedbackinterfaces
architecture
![Page 15: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/15.jpg)
water end use
water flowfeedbackinterfaces
architecture
![Page 16: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/16.jpg)
water towerwater tower
thermal expansion
tank
hosespigot
utility water meter
pressure regulator
laundry
bathroom 1
hot water heater bathroom 2
dishwasher
incoming cold water from supply line
kitchen
![Page 17: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/17.jpg)
40
50
60
70
80
Cold Line Pressure(Hose Spigot)
0 94.5
time (s)
psi
open close
bathroom sink pressure signal
![Page 18: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/18.jpg)
40
50
60
70
80
Cold Line Pressure(Hose Spigot)
0 94.5
time (s)
psi
open close
bathroom sink pressure signal
flow volume
![Page 19: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/19.jpg)
Bucket Trials
• 9 Homes• 41
Fixtures• 541 trials
![Page 20: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/20.jpg)
gpm% o
f act
ual
volu
me
Neptune T-10 Water meter
Training on all fixturesOnly kitchen + bath
volume prediction
Flow Trace Meter
![Page 21: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/21.jpg)
![Page 22: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/22.jpg)
hot and cold
• train on 4 trials, • median error: 0.2 gpm• 75th percentile: 0.42 gpm
![Page 23: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/23.jpg)
water end use
water flowfeedbackinterfaces
architecture
![Page 24: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/24.jpg)
toilet78.4 gallons
shower62.4 gallons
bath6.5 gallons
today‘s usage
bathroom sink 14.2 gallons
bathroom sink 20.8 gallons
![Page 25: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/25.jpg)
toilet78.4 gallons
shower10.4 gallons
bath0.0 gallons
bathroom sink 11.2 gallons
bathroom sink 20.8 gallons
shower52.4 gallons
bath6.5 gallons
bathroom sink 13.2 gallons
bathroom sink 22.4 gallons
today‘s usage: hot vs cold
![Page 26: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/26.jpg)
hydrosenseexample pressure waves
bath open
dishwasher open
upstairs toilet flush
downstairs toilet flush
downstairs shower open
kitchen sink cold open
kitchen sink hot open
![Page 27: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/27.jpg)
toilet
natural water use
70
50
30
pres
sure
(psi)
kitchen sink kitchen sinkbathroom sink
![Page 28: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/28.jpg)
water tower
thermal expansion
tank
hosespigot
utility water meter
pressure regulator
laundry
bathroom 1
hot water heater bathroom 2
dishwasher
incoming cold water from supply line
kitchen
data collection
Larson and Froehlich, et al., Pervasive 2011
![Page 29: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/29.jpg)
![Page 30: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/30.jpg)
![Page 31: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/31.jpg)
![Page 32: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/32.jpg)
![Page 33: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/33.jpg)
![Page 34: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/34.jpg)
totals
days 33 33 30 27 33 156
events 2374 3075 4754 2499 2578 14,960
events/day 71.9 93.2 158.5 92.6 78.1 95.9
compound 22.2% 21.8% 16.6% 32% 21.3% 21.9%
5-week dataset
Larson and Froehlich, et al., Pervasive 2011
![Page 35: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/35.jpg)
Fixtures Cnt Total Hot Cold Mixed Compound AvgDuration
KitchenSink 5 5494 (36.7%) 44.4% 25.8% 29.9% 9.9% 22.4 secsM. Bathroom Sink 7 3934 (26.3%) 53.7% 32.9% 13.4% 41.8% 27.2 secsM. Bathroom Toilet 5 1886 (12.6%) 0.0% 100% 0.0% 10.8% 43.6 secsS. Bathroom Sink 4 1369 (9.2%) 45.1% 46.5% 8.3% 35.6% 30.9 secsWashing Machine 4 430 (2.9%) 21.6% 75.6% 2.8% 18.1% 1.6 minsM. Bathroom Bath 5 423 (2.8%) 53% 8.3% 38.8% 25.2% 43.4 secsS. Bathroom Toilet 3 341 (2.3%) 0.0% 100% 0.0% 9.4% 27.2 secs
M. Bathroom Shower
5 261 (1.7%) 21.1% 1.5% 77.4% 15.3% 8.7 minsDishwasher 3 261 (1.7%) 100% 0.0% 0.0% 5.7% 1.2 mins
S. Bathroom Bath 2 59 (0.39%) 8.5% 0.0% 91.5% 6.8% 20.7 secsS. Bathroom
Shower2 47 (0.31%) 23.4% 0.0% 76.% 2.1% 9.4 mins
Totals 53 14960 5870 (39.2%) 6087 (40.7%) 3003 (20.1%) 21.9% 49.1 secs
5-week dataset
![Page 36: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/36.jpg)
three levels of granularity
valve levele.g., upstairs bathroom faucet hot water activated
1
fixture levele.g., upstairs bathroom faucet activated
2
fixture category levele.g., faucet activated
3
![Page 37: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/37.jpg)
hydrosense classification resultsreal-world water usage data
0%
20%
40%
60%
80%
100%
75.5% 89.5% 95.9%
one sensor
fixture categoryfixturevalve
*error bars = std error *10-fold cross validation, 15000 events
![Page 38: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/38.jpg)
0%
20%
40%
60%
80%
100%
75.5% 89.5% 95.9%82.4% 93.5% 97.7%
hydrosense classification resultsreal-world water usage data
two sensors
fixture categoryfixturevalve
*error bars = std error
one sensor
*10-fold cross validation, 15000 events
![Page 39: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/39.jpg)
0 1 2 3 4 5 6 7 8 9 10 1170
80
90
Days of Training Data
Clas
sific
ation
Acc
urac
ies
(%)
hydrosense classification results
fixture level
![Page 40: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/40.jpg)
water end use
water flowfeedbackinterfaces
architecture
![Page 41: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/41.jpg)
![Page 42: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/42.jpg)
What are the key gaps in water usage understanding?
What aspects of disaggregated data are potential users interested in and what sort of reactions do the visualizations provoke?
How might these visualizations impact behavior?
1
2
3
Key Questions
Froehlich, et al., CHI2012
![Page 43: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/43.jpg)
Data Granulari
ty Individual Fixture
Fixture Category
Activity Hot and Cold
Time Granulari
ty So Far Today So Far This Week
So Far This Month
Measurement
Unit In Gallons In Dollars Dollars / Gallons
Including Sewage
Comparison
Self Comparison
To Others Social/SelfTo A Goal
Design Dimensions Explored
DESIGN SET 1: ISOLATING DESIGN DIMENSIONS
![Page 44: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/44.jpg)
Design Probes ExploredDESIGN SET 2: DESIGN PROBES
Spatial
Per-Occupant
Time-Series
Rainflow
Other
AquaticEco-system
![Page 45: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/45.jpg)
water savingstracker
“Frank” the fish
Water savings goal
met
“Frank” the fish meets his mate
New water savings goal
met
Frank and his mate
have childrenand so on…
display is also
interactive so fish
respond to touch
DESIGN SET 2: DESIGN PROBES
Aquatic Ecosystem View
![Page 46: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/46.jpg)
DESIGN SET 2: DESIGN PROBES
Other Design Probes
Geographic Comparisons Dashboards
Metaphorical Unit Designs Recommendations
Froehlich, et al., CHI2012
![Page 47: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/47.jpg)
Eco-feedback displays do not just visualize consumption, they document household
activities
![Page 49: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/49.jpg)
water end use
water flowfeedbackinterfaces
architecture
![Page 50: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/50.jpg)
![Page 51: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/51.jpg)
![Page 52: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/52.jpg)
saveprocess (local) update
install for two weeksstream to cloudupdate global models
save to disk/cloudkeep diary (sparse)infer activity later
![Page 53: ACEEE 2012](https://reader038.vdocuments.us/reader038/viewer/2022102700/5499802fb479597a608b45b1/html5/thumbnails/53.jpg)
Sensing and ArchitectureEric Larson
[email protected]@ec_larsoneclarson.com
Indirect Water End Use Sensing:Consumption, Disaggregation, and Feedback
Behavior ChangeJon Froehlich
[email protected]@jonfroehlichcs.umd.edu/~jonf
UNIVERSITY ofWASHINGTON
Product DevelopmentKevin Ashton
[email protected] @kevin_ashton