Accurate, quantitative results Completely automated procedure Bi-directional interfacing Results in 10 minutes Now with progesterone Accurate in-house immunodiagnostics. Using proven, fluorescence immunoassay technology, this bench top analyzer ensures impressive sensitivity for accurate detection of Total T4, cTSH, Cortisol, Bile Acids and Progesterone in the clinic. Along with confidence in results, SPF Fluorometry allows for a simplified testing protocol and immediate diagnostic information with a test time of 10 minutes, start to finish. www.heska.com Immunodiagnostic Analyzer i

Upload: others

Post on 27-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Accurate, quantitative results

Completely automated procedure

Bi-directional interfacing

Results in 10 minutes

Now with progesterone

Accurate in-house immunodiagnostics.Using proven, fluorescence immunoassay technology, this bench top analyzer ensures impressive sensitivity for accurate detection of Total T4, cTSH, Cortisol, Bile Acids and Progesterone in the clinic. Along with confidence in results, SPF Fluorometry allows for a simplified testing protocol and immediate diagnostic information with a test time of 10 minutes, start to finish.

www.heska.com

Immunodiagnostic Analyzer

i

Convenience• Simplified Interface and operation with a

small bench top footprint• Completely automated procedure with

no measurement, mixing, conjugating or incubating

Reliability• The industry’s first in-house cTSH solution• Respected Fujifilm technology measures

accurately and quantitatively

Load tip3Load consumables2Load sample1

Diagnosing Hypothyroidism

Easy Operation 4-step easy measurement

www.heska.com 800.464.3752

©2019 Heska Corporation. All Rights Reserved. HESKA, Element i and HeskaView Integrated Software are registered trademarks of Heska Corporation in the U.S. and other countries. US19LT0103

Features:

Ei

Test ParametersMEASURED PARAMETERS

Total T4

Efficient • Assign, unassign or delete multiple

items at once

Simple data management• Rapidly retrieve trending data from

patient record

Resultsand

Reporting

The Element i Immunodiagnostic Analyzer integrates with your Practice Management Software, HeskaView Integrated Software® Program or the Heska Data Capture Utility, for seamless patient data management.

Integration

Chemistry (DRI-CHEM) - Thursday, June 5, 2014 1:01 PM

Dog ID:122

BUN21.9 9.0 - 29.0 mg/dl

Creatinine1.0 0.4 - 1.4 mg/dl

Total Protein8.6 H 5.5 - 7.6 g/dl

Globulin6.2 H 2.0 - 3.6 g/dl

Glucose96 75 - 125 mg/dl

ALT (GPT)29 0 - 80

U/l

ALP122 0 - 140 U/l

Element POC_1 - Thursday, June 5, 2014 1:01 PM

Dog ID:122

pO249.0 24.0 - 54.0 mmHg

cSO281.4 40.0 - 90.0 %

pCO239.7 30.0 - 47.0 mmHg

Bicarbonate20.7 16.0 - 28.0 mmol/L

cTCO221.9 18.0 - 28.0 mmol/L

pH7.325 L 7.360 - 7.460

BE, ECF-5.4 L -5.0 - 5.0 mmol/L

Sodium147 140 - 151 mmol/L

Potassium4.2 3.5 - 5.0 mmol/L

Calcium, ionized1.36 1.13 - 1.42 mmol/L

Lactate4.76 H 0.60 - 3.00 mmol/L

Glucose71 63 - 124 mg/dL

HCT37 36 - 55 %

ElementHT5_1 - Tuesday, February 24, 2015 4:25 PM

Dog ID:122

WBC13.74 6.00 - 17.00 103/uL

NEU8.75 3.62 - 12.30 103/uL

LYM3.78 0.83 - 4.91 103/uL

MONO0.94 0.14 - 1.97 103/uL

EOS0.20 0.04 - 1.62 103/uL

BAS0.07 0.00 - 0.12 103/uL

NEU %63.7 52.0 - 81.0 %

LYM %27.5 12.0 - 33.0 %

MONO %6.8 2.0 - 13.0 %

EOS %1.5 0.5 - 10.0 %

BAS %0.5 0.0 - 1.3 %

RBC6.69 5.10 - 8.50 106/uL

HGB17.6 11.0 - 19.0 g/dL

HCT46.1 33.0 - 56.0 %

MCV68.9 60.0 - 76.0 fL

MCH26.3 20.0 - 27.0 pg

MCHC38.2 H 30.0 - 38.0 g/dL

RDW %13.4 12.5 - 17.2 %

PLT269 117 - 490 103/uL

MPV10.5 8.0 - 14.1 fL

Chemistry (DRI-CHEM) - Thursday, August 27, 2015 10:47 AM

Dog ID:122

T41.61 1.40 - 4.10 ug/dL

Client: Sam MillerSpecies: Dog

Sex: MN

Patient: OliverBreed: Jack Russell Terrier

Birthdate: 2/14/2013

Patient ID: 122Veterinarian: Dr. Jones

Age: 2 yrs 8 mo.

TESTResult Flag Normal Range Units

Low T4 and High cTSH are two sides of the same coin. When the thyroid gland does not produce enough T4, a signal is sent from the pituitary gland in the form of increased cTSH (thyroid stimulating hormone). cTSH signals the thyroid gland to produce more T4. If the thyroid gland is unable to respond by producing adequate levels of T4 in response to higher concentrations of cTSH, hypothyroidism should be the primary differential.

Measure Total T4 and cTSH• Relying on low T4 alone is not sufficient to diagnose

hypothyroidism• Normal T4 and Normal cTSH largely rules out hypothyroidism• Low T4 and High cTSH largely confirms hypothyroidism

START 4

Screen for hyper or hypothyroidism and monitor patients being treated for thyroid disorders.

cTSH

Cortisol

Bile Acids

NEW!Progesterone

Following abnormal Total T4 result, test TSH forimmediate in-house hypothyroidism confirmation.

Screen for Cushing’s or Addison’s Disease.

Accurate pre and post prandial measurements fordiagnosis of liver diseases.

Predict ovulation, parturition and identify reproductive abnormalities.