according to en13201 - selectsc.pl filedetas doo industrijska 21 - sveta nedelja, croatia tel. 00385...

18
DETAS doo Industrijska 21 - Sveta Nedelja, Croatia Tel. 00385 1 3370 050 - [email protected] An ISO 9001:2008 certified company www.dleds.com 1 Fare clic per modificare lo stile del sottotitolo dello schema L i g h t s t h a t s a v e l i f e PEDESTRIAN CROSSING LIGHTING according to EN13201

Upload: others

Post on 21-Sep-2019

2 views

Category:

Documents


0 download

TRANSCRIPT

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com1

Fare clic per modificare lo stile del sottotitolo dello

schema

L i g h t s t h a t s a v e l i f e

PEDESTRIAN CROSSING LIGHTINGaccording to EN13201

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com2

Fare clic per modificare lo stile del sottotitolo dello

schema

Why lighting up pedestrian crossings is so importan t?Accidents involving pedestrians

occurs mostly on crosswalks

At night and with poor visibility,the pedestrian crossings and the pedestrians

must be conveniently illuminated

pedestrians andpedestrian crossings

good visibility

= road safety

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com3

Fare clic per modificare lo stile del sottotitolo dello

schema

Types of illuminance: Eh and Ev

Basicilluminance

The most important factor for

pedestrian’s safety

Horizontal illuminance(Eh)

Vertical illuminance(Ev)

According to the standard EN13201, two types of illuminance involve pedestrian crossings:

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com4

Fare clic per modificare lo stile del sottotitolo dello

schema

Horizontal illuminance (Eh)

• Enhance trampling visibility to the pedestrian and ensure ease of crossing the road

Vertical illuminance (Ev)

• Enhance pedestrian visibility to the driver ,including from distance

• Allow the pedestrian visibility,including the pedestrianwaiting area

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com5

Fare clic per modificare lo stile del sottotitolo dello

schema

Types of illuminance: Ev and its key role

Vertical illuminance(Ev)

Horizontal illuminance

(Eh)

Ev: the key for pedestrian crossing safety

• Eh and Ev must comply with the values laid downby standards

• according to the specific requirements, it is possibleto reach Eh and Ev values higher than the laid downby standards(i.e. on the basis of the level of danger of the pedestrian crossing)

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com6

Fare clic per modificare lo stile del sottotitolo dello

schema

SAFETY of PEDESTRIAN CROSSINGS

ILLUMINANCE LEVEL ACCORDING TO EN13201

THE MAXIMUM GOAL

(EN13201 EV1)

THE MINIMUM POWER CONSUMPTION

(different models, from 55W)

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com7

Fare clic per modificare lo stile del sottotitolo dello

schema

Lighting the waiting area: key factor after Ev

• Preventing accidents as the pedestrian passes through lighting within the waiting area

• Aside from the regulations that grant the right of way tothe pedestrian or to the driver, there is the importanceto light up the waiting area

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com8

Fare clic per modificare lo stile del sottotitolo dello

schema

The lighting of pedestrian crossings

ARTIFICIAL LIGHTING OF PEDESTRIAN CROSSINGDESCRIPTION STANDARD ADDITIONAL INFORMATION

Area to beilluminated

The whole section of thepedestrian crossing plusa zone of one meter onall the sides, included thesidewalk

Contrast from 2 to 3 timesRatio between:• Eh of the illuminated area of the crossing • Eh of the road

Eh 50 lux at least

In any case, it must be a value that assures the selected and/or laid down by the law contrast

Ev 50 lux at least(Ev1 class)

Measured on the axis of the pedestrian crossing atheight≤ 1.50 m, in any case Eh on that axismust be superior to Ev of the road, according tothe ratio chosen for the contrast

U 0,75

LEGENDA: Eh=horizontal illuminance, Ev=vertical illuminance, U=uniformity

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com9

Fare clic per modificare lo stile del sottotitolo dello

schema

DLEDS solutions

1 - LED lights installed overhanging

2 - Pole mounted lighting fixture

• LED lights : Trilogy or Maya• Easier installation• high level of horizontal

illuminance (Eh);• lower level of vertical

illuminance (Ev) compared to the other solution

LED lights : Stratos or Maya,equipped with special optics16A2SX and16A2DX;

pole located at a distance of 1-1,5 mfrom the beginning of the crosswalks, on the left or on the right;

high level of vertical illuminance(Ev)

large size of illuminated area and lighting of pedestrian waiting areas.

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com10

Fare clic per modificare lo stile del sottotitolo dello

schema

Pedestrian crossingconventional lights vs. DLEDS solution

PARAMETER BEFORE AFTERcolor rendering very poor rendering (CRI index) very high rendering (CRI index)

light annoying , especially when the road is wet

white . Really comfortable , thanks toour anti-glare optic

energy consumption

high (2-3 times more comparedto our solution with LEDs)

lower , thanks to our LED technology

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com11

Fare clic per modificare lo stile del sottotitolo dello

schema

DLEDS products for pedestrian crossings (1/3)

Trilogy (solution 1, installed overhanging)

LED lights:

– alluminium body,

– 4 mm tempered glass lens

– LED LM80 certified

– LED with L70 > 100.000 hours ;

– protection IP66;

– available with different lengths:

30 cm, 60 cm, 100 cm

TRILOGY N

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com12

Fare clic per modificare lo stile del sottotitolo dello

schema

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com13

Fare clic per modificare lo stile del sottotitolo dello

schema

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com14

Fare clic per modificare lo stile del sottotitolo dello

schema

DLEDS products for pedestrian crossings (2/3)

Maya 3 (solution 1, solution 2)

LED lights:

– alluminium body,

– tempered glass;

– LED LM80 certified;

– LED with L70 > 50.000 hours ;

– protection IP66; Solution 1: optic 13Solution 2 : optics 16A2SX and 16A2DX

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com15

Fare clic per modificare lo stile del sottotitolo dello

schema

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com16

Fare clic per modificare lo stile del sottotitolo dello

schema

Stratos (solution 2)

Compact and elegant LED light with

excellent performance/price ratio:

– ENEC certified;

– Patented corrosion free aluminium

die cast body;

– LED certified LM80

– LED with L70 >50.000/100.000 hours ;

– protection IP66;

– dimmable on request;

– photobiological safety=no risk

optics 16A2SX and 16A2DX

DLEDS products for pedestrian crossings (3/3)

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com17

Fare clic per modificare lo stile del sottotitolo dello

schema

DETAS doo

Industrijska 21 - Sveta Nedelja, Croatia

Tel. 00385 1 3370 050 - [email protected]

An ISO 9001:2008 certified company

www.dleds.com18

Fare clic per modificare lo stile del sottotitolo dello

schema

DLEDS – Contact

DLEDS - Division of DETAS dooCompany web-site: www.dleds.com

Matija BartosSales Manager for East CountriesE-mail: xxxxMobile: xxxxx