Page 1: ACCELERATE THE SANITIZING POWER OF UV RAYS ......ISO 2409 / ASTM D 3359 MECHANICAL STABILITY THICKNESS 0.30mm – 0.40mm – 0.50mm – 0.70mm – 0.75mm – 1.0mm WIDTH ≤ 1250mm

ACCELERATE THE SANITIZING POWER OF UV RAYS

Page 2: ACCELERATE THE SANITIZING POWER OF UV RAYS ......ISO 2409 / ASTM D 3359 MECHANICAL STABILITY THICKNESS 0.30mm – 0.40mm – 0.50mm – 0.70mm – 0.75mm – 1.0mm WIDTH ≤ 1250mm

vega®UV-C is the high-reflective aluminium surface designed specifically by Almeco to accelerate the sanitizing power of UV rays.

Ultraviolet light offers a quick and effective solution to sterilize and sanitize environments and objects.The UV-C band (the wavelengths between 200 nm and 280 nm) is considered “UV germicidal”.vega®UV-C increases the effectiveness of the UV system through reflection; its highly reflective aluminum surface allows to reach 91% of the UV rays reflection thus increasing the disinfection power.

The UV-C radiation is absorbed by the DNA and RNA of micro-organisms, such as viruses and bacteria, modifying their structure and hindering their reproduction. With a sufficiently powerful radiation intensity, the UV-C is a very reliable, fast and environmentally friendly disinfection method because it doesn’t require the use of chemical agents.

vega®UV-C reflective aluminum surface can be used to cover internal walls of equipment and medical devices.To considerably improve the effectiveness and efficiency of the appliances, Almeco’s optical engineers support you in the development and production of reflectors to optimize the emission of UV radiation by concentrating it where it is needed.

Why vega®UV-C ?

Why specifically UV-C rays?

How to use vega®UV-C ?

disinfection mobile system made with high reflective vega®UV-C optics by ®

Page 3: ACCELERATE THE SANITIZING POWER OF UV RAYS ......ISO 2409 / ASTM D 3359 MECHANICAL STABILITY THICKNESS 0.30mm – 0.40mm – 0.50mm – 0.70mm – 0.75mm – 1.0mm WIDTH ≤ 1250mm

We contribute to sanitize the environmental with quick and sustainable solutions.

0

20

40

60

80

100

250 260 270 280 290 300

Refle

ctan

ce %

Wavelength [nm]

Anodized aluminum

Germicidal effectivness

0

20

40

60

80

100

250 350 450 550 650 750

Refle

ctan

ce %

Wavelength [nm]

PVD coated aluminium for general lighting (TR = 95%)

Anodized aluminum

Germicidal effectivness

SPECTRUM UV-C EFFECTIVNESS

COMPARISON REFLECTANCE SPECTRA OF DIFFERENT MATERIALS

vacuum UV UV-BUV-C UV-A visible spectrum

10-16 10-14 10-12 10-10 10-8 10-6 10-4 10-2 100 102 104 106 108 λ(m)

1024 1022 1020 1018 1016 1014 1012 1010 108 106 104 102 100 ν(Hz)

γ rays X rays UV IR Microwave Long radio wavesRadio wavesFM AM

Page 4: ACCELERATE THE SANITIZING POWER OF UV RAYS ......ISO 2409 / ASTM D 3359 MECHANICAL STABILITY THICKNESS 0.30mm – 0.40mm – 0.50mm – 0.70mm – 0.75mm – 1.0mm WIDTH ≤ 1250mm

Almeco GmbH

Claude Breda Strasse, 3 D-06406 Bernburg - Germany

T +49 3471 3465500F +49 3471 3465509

[email protected]

www.almecogroup.com

Almeco SpA

Via della Liberazione 1520098 San Giuliano M.se (Mi) - Italy

T +39 02 988963 1F +39 02 988963 99

[email protected]

Almeco USA Inc.

1610 Spectrum DriveLawrenceville, GA 30043 - USA

T +1 770 449 3454F +1 770 449 3677

[email protected]

Value Standards

CROSS HATCH TESTNo more than 2 of 100 test fields

delaminating ISO 2409 / ASTM D 3359

MECHANICAL STABILITY

THICKNESS 0.30mm – 0.40mm – 0.50mm – 0.70mm – 0.75mm – 1.0mm

WIDTH ≤ 1250mm

AVAILABLE SIZES

Typical Standards

VUV-C: HEMISPHERIC REFLECTANCE @ 254nm 90% ± 2% -

VUV-C: HEMISPHERIC REFLECTANCE @ 270nm 91% ± 2% -

VUV-C: HEMISPHERIC REFLECTANCE @ 280nm 90.5% ± 2% -

IRIDESCENCE absent INTERNAL

COLOUR VALUES – a* -3 < a* < 2 CIE Lab (D65 / 10°)

COLOUR VALUES – b* -5 < b* < 2 CIE Lab (D65 / 10°)

OPTICAL VALUES

Conditions Time Reflectance change Cross hatch test Standards

OVEN – 250°C 500 h < 1% OK

CLIMATE CHAMBER85°C – 85% r.H.

1000 h < 1% OK

UV 0.53W/m2 @ 340nm 500 h < 1% OK

CONDENSATION TEST (60°C / 95% r.H.) 100 h < 1% OK

ENVIRONMENTAL STABILITY

L121

– E

NG –

05/