acc building utilities

Upload: charmaine-cruz

Post on 04-Mar-2016

10 views

Category:

Documents


0 download

TRANSCRIPT

BUILDING UTILITIES PLUMBING MECH/ELECT ACCOUSTICS

BUILDING UTILITIESPLUMBING MECH/ELECT ACCOUSTICS1. WHAT IS THE SIZE OF THE SUPPLY PIPE FROM THE DISTRIBUTING MAIN PIPE TO PRIMARY BRANCH?A.75 MMC. 100 MMB. 40 MMD. 50 MM

1. WHAT IS THE SIZE OF THE SUPPLY PIPE FROM THE DISTRIBUTING MAIN PIPE TO PRIMARY BRANCH?A.75 MMC. 100 MMB. 40 MMD. 50 MM OR 2

2. WHICH IS NOT INSTALLED UNDERGROUND A.CISTERN C. DOWNSPOUTB. SEPTIC TANK D. MANHOLE

2. WHICH IS NOT INSTALLED UNDERGROUND A.CISTERN C. DOWNSPOUTB. SEPTIC TANK D. MANHOLE

3. WHAT IS THE COLOR OF PIPES USED FOR STEAM ? A.LIGHT BLUEC. YELLOWB. GRAYD. BLUE

3. WHAT IS THE COLOR OF PIPES USED FOR STEAM ? A.LIGHT BLUEC. YELLOWB. GRAYD. BLUE

4. WHAT IS THE COLOR OF PIPES CARRYING SALTWATER?A.GREEN C. YELLOWB. GRAYD. ORANGE

4. WHAT IS THE COLOR OF PIPES CARRYING SALTWATER?A.GREEN C. YELLOWB. GRAYD. ORANGE

5. WHICH SHOULD NOT BE USED FOR WATER MAIN PIPE?A. GALVANIZED IRONC. STAINLESS STEELB. CERAMICD. PVC

5. WHICH SHOULD NOT BE USED FOR WATER MAIN PIPE?A. GALVANIZED IRONC. STAINLESS STEELB. CERAMICD. PVC

6. WHICH PIPE IS SUSCEPTIBLE TO UV RAYS?A. GALVANIZED IRONC. STAINLESS STEELB. CAST IROND. PVC

6. WHICH PIPE IS SUSCEPTIBLE TO UV RAYS?A. GALVANIZED IRONC. STAINLESS STEELB. CAST IROND. PVC

WATER TRAPS ARE USED TO PREVENT FOUL ODOR FROM COMING OUT. WHICH OF THE FOLLOWING DOES NOT HAVE A P-TRAP?A. LAVATORYC. KITCHEN SINKB. WATER CLOSETD. FLOOR DRAIN

WATER TRAPS ARE USED TO PREVENT FOUL ODOR FROM COMING OUT. WHICH OF THE FOLLOWING DOES NOT HAVE A P-TRAP?A. LAVATORYC. KITCHEN SINKB. WATER CLOSETD. FLOOR DRAIN

7. FOR T&B AT THE GROUND FLOOR, WHICH WOULD YOU CONNECT DIRECTLY UNDER A FLOOR DRAIN?SLEEVEC. ELBOWP-TRAPD. NIPPLE

7. FOR T&B AT THE GROUND FLOOR, WHICH WOULD YOU CONNECT DIRECTLY UNDER A FLOOR DRAIN?SLEEVEC. ELBOWP-TRAPD. NIPPLE

8. FOR T&B AT THE GROUND FLOOR, WHICH WOULD YOU CONNECT DIRECTLY UNDER A FLOOR DRAIN?SLEEVEC. ELBOWP-TRAPD. NIPPLE

9. WHAT DO YOU CALL THE LIQUID WASTE (WITHOUT URINE, FECES OR INDUSTRIAL WASTE) DISCHARGES INTO THE SEWER? STORM WATERC. GRAY WATERGROUND WATERD. BLACK WATER

9. WHAT DO YOU CALL THE LIQUID WASTE (WITHOUT URINE, FECES OR INDUSTRIAL WASTE) DISCHARGES INTO THE SEWER? STORM WATERC. GRAY WATERGROUND WATERD. BLACK WATER

10.IN RECYCLING AND TREATMENT OF WATER FOR LOW COST AND ECONOMIC USE WHERE CAN YOU USE GRAY WATER?

A. FLUSHING OF TOILET C. AGRICULTURAL IRRIGATIONB. WASHING DISHES D. WASHING CLOTHES 10.IN RECYCLING AND TREATMENT OF WATER FOR LOW COST AND ECONOMIC USE WHERE CAN YOU USE GRAY WATER?

A. FLUSHING OF TOILET C. AGRICULTURAL IRRIGATIONB. WASHING DISHES D. WASHING CLOTHES 11.A SEWAGE TREATMENT PROCESS THAT INVOLVES THE USE OF HYDROCHLORIDE TO KILL PATHOGENIC BACTERIA?

A. AERATION C. DISTILLATIONB. DISINFECTION D. FILTRATION 11.A SEWAGE TREATMENT PROCESS THAT INVOLVES THE USE OF HYDROCHLORIDE TO KILL PATHOGENIC BACTERIA?

A. AERATION C. DISTILLATIONB. DISINFECTION D. FILTRATION 12.WHAT IS ANOTHER TERM FOR A FAUCET?

A. SPIGOT C. VALVEB. BIB D. HOSE 12.WHAT IS ANOTHER TERM FOR A FAUCET?

A. SPIGOT C. VALVEB. BIB D. HOSE 13.IN A PLUMBING SYSTEM, PIPES ARE ELECTRICAL WIRES. WHAT IS THE EQUIVALENT OF SWITCHES?

A. ELBOW C. VALVESB. TEE D. TRAP13.IN A PLUMBING SYSTEM, PIPES ARE ELECTRICAL WIRES. WHAT IS THE EQUIVALENT OF SWITCHES?

A. ELBOW C. VALVESB. TEE D. TRAP14.ON THE FOLLOWING FIXTURES INSIDE A T&B WHICH HAS THE GREATEST WATER PRESSURE?

A. FAUCET C. SHOWER B. WATER CLOSET D. ALL HAVE EQUAL PRESSURE14.ON THE FOLLOWING FIXTURES INSIDE A T&B WHICH HAS THE GREATEST WATER PRESSURE?

A. FAUCET C. SHOWER B. WATER CLOSET D. ALL HAVE EQUAL PRESSURE15.WHAT DO YOU CALL THE RECESS IN WALLS INTENDED FOR PIPES?

A.CHASEC. DUCTB. SLEEVE D. DRUM15.WHAT DO YOU CALL THE RECESS IN WALLS INTENDED FOR PIPES?

A.CHASEC. DUCTB. SLEEVE D. DRUM15.WHAT DO YOU CALL THE WATER-TIGHT RECEPTACLE USED TO STORE HOUSEHOLD WASTE?A.WATER TANK C. SEPTIC TANKB. GREESE TRAP D. SEWER 15.WHAT DO YOU CALL THE WATER-TIGHT RECEPTACLE USED TO STORE HOUSEHOLD WASTE?A.WATER TANK C. SEPTIC TANKB. GREESE TRAP D. SEWER 16.IN A STORM DRAIN SYSTEM, IT IS USED TO PREVENT AGGREGATES, DEBRIS AND OTHER UNWANTED OBJECTS FROM ENTERING THE DRAINAGE SYSTEM? A.TRAP C. SEPTIC TANKB. GUTTER D. CATCH BASIN16.IN A STORM DRAIN SYSTEM, IT IS USED TO PREVENT AGGREGATES, DEBRIS AND OTHER UNWANTED OBJECTS FROM ENTERING THE DRAINAGE SYSTEM? A.TRAP C. SEPTIC TANKB. GUTTER D. CATCH BASIN17. WHAT IS THE MINIMUM SLOPE OF HORIZONTAL PIPES? A.2% C. 4%B. 3% D. 5%17. WHAT IS THE MINIMUM SLOPE OF HORIZONTAL PIPES? A.2% C. 4%B. 3% D. 5%18. WHAT IS THE MINIMUM SIZE OF A FLOOR DRAIN COVER? A.3X3 C. 2X2B. 4X4D. 5X518. WHAT IS THE MINIMUM SIZE OF A FLOOR DRAIN COVER? A.3X3 C. 2X2B. 4X4D. 5X518. ACCORDINGH TO NPC, PIPE SUPPORT SHOULD EVERY? A.50 MM C. 100 MMB. 200 MMD. 150 MM18. ACCORDINGH TO NPC, PIPE SUPPORT SHOULD EVERY? A.50 MM C. 100 MMB. 200 MMD. 150 MM19. ALLOWABLE SLOPE OF SANITARY SEWER?

A.1FT. OF 1 METER C. OF 1 METERB. OF 1 METERD. OF 1 FOOT19. ALLOWABLE SLOPE OF SANITARY SEWER?

A.1FT. OF 1 METER C. OF 1 METERB. OF 1 METERD. OF 1 FOOT20. WHAT TYPE OF PIPE IS NOT USED FOR UNDERGROUND INSTALLATION?

A.PVC PIPE C. GI PIPEB. CLAY PIPED. STAINLESS PIPE20. WHAT TYPE OF PIPE IS NOT USED FOR UNDERGROUND INSTALLATION?

A.PVC PIPE C. GI PIPEB. CLAY PIPED. STAINLESS PIPE21. A FITTING USED TO SPLIT THE FLOW OF WATER

A.REDUCER C. COUPLINGB. TEED. SPLITTER21. A FITTING USED TO SPLIT THE FLOW OF WATER

A.REDUCER C. COUPLINGB. TEED. SPLITTERWHAT IS THE INSIDE DIAMETER OF A 200 MM PVC PIPE?

A.194 C. 188.2B. 195D. 190WHAT IS THE INSIDE DIAMETER OF A 200 MM PVC PIPE?

A.194 C. 188.2B. 195D. 19023. WHAT WILL YOU USE TO CONNECT TWO PIPES OF UNEQUAL SIZE?

A.TEE C. REDUCERB. HUBD. CONNECTOR23. WHAT WILL YOU USE TO CONNECT TWO PIPES OF UNEQUAL SIZE?

A.TEE C. REDUCERB. HUBD. CONNECTOR24. WHICH SHOULD NOT BE PLACED IN LINE WITH THE BEAM?

A.LAVATORY C. KITCHEN SINKB. WATER CLOSETD. SHOWER24. WHICH SHOULD NOT BE PLACED IN LINE WITH THE BEAM?

A.LAVATORY C. KITCHEN SINKB. WATER CLOSETD. SHOWER24. WHICH SHOULD NOT BE PLACED IN LINE WITH THE BEAM?

A.LAVATORY C. KITCHEN SINKB. WATER CLOSETD. SHOWERPLUMBING SITUATION : IN A TOWNHOUSE DEVELOPMENTPROJECTWHO IS IN-CHARGE OF ROUGHING-IN OF SANITARY PIPES?

A.MASON C. FOREMAN B. LABOR D. PLUMBERPLUMBING SITUATION : IN A TOWNHOUSE DEVELOPMENTPROJECTWHO IS IN-CHARGE OF ROUGHING-IN OF SANITARY PIPES?

A.MASON C. FOREMAN B. LABOR D. PLUMBERPLUMBING SITUATION : IN A TOWNHOUSE DEVELOPMENTPROJECT

2. WHO IS IN-CHARGE OF PLOTTING POINTS AND STAKING AT THE SITE?

A.OWNER C. ARCHITECT B. ENGINEERD. MASTER PLUMBERPLUMBING SITUATION : IN A TOWNHOUSE DEVELOPMENTPROJECT

2. WHO IS IN-CHARGE OF PLOTTING POINTS AND STAKING AT THE SITE?

A.OWNER C. ARCHITECT B. ENGINEERD. MASTER PLUMBERPLUMBING SITUATION : IN A TOWNHOUSE DEVELOPMENTPROJECT

3. WHICH IS AN ILLEGAL THING TO DO?

A.TAP DIRECTLY FROM WATER MAIN TO THE FIXTURES UNITSB. PROVIDE A CISTERN THEN PROVIDE WATER TO THE TOWN HOUSEUNITSC. PROVIDE A BOOSTER PUMP DIRECTLY GETTING WATER FROM MAIN THEN DISTRIBUTED TO THE TOWNHOUSESPLUMBING SITUATION : IN A TOWNHOUSE DEVELOPMENTPROJECT

3. WHICH IS AN ILLEGAL THING TO DO?

A.TAP DIRECTLY FROM WATER MAIN TO THE FIXTURES UNITSB. PROVIDE A CISTERN THEN PROVIDE WATER TO THE TOWN HOUSEUNITSC. PROVIDE A BOOSTER PUMP DIRECTLY GETTING WATER FROM MAIN THEN DISTRIBUTED TO THE TOWNHOUSES1. A DEVICE USED TO DETERMINE THE AIR TEMPERATURE OF A ROOM?

A.THERMOSTAT C. THERMOMETER B. WIRE GUAGED. COOLANT1. A DEVICE USED TO DETERMINE THE AIR TEMPERATURE OF A ROOM?

A.THERMOSTAT C. THERMOMETER B. WIRE GUAGED. COOLANT1. WHAT DO YOU CALL THE COMPONENT OF A SPLIT TYPE AIRCONDITIONING SYSTEM WHICH IS LOCATED OUTSIDE THE STRUCTURE?A.EVAPORATOR C. CONDENSERB. VENT D. COOLERWHAT DO YOU CALL THE COMPONENT OF A SPLIT TYPE AIRCONDITIONING SYSTEM WHICH IS LOCATED OUTSIDE THE STRUCTURE?

A.EVAPORATOR C. CONDENSERB. VENT D. COOLER2.WHAT IS THE LIMITATION IN THE INSTALLATION OF A SPLIT TYPE AC?

A.IT SHOULD BE LOCATED NEAR A WINDOWB. IT SHOULD NOT BE LOCATED NEAR THE FLOORC. ITS TUBE SHALL NOT EXCEED 3M FROM CONDENSER TO EVAPORATORD. ALL OF THE ABOVE2.WHAT IS THE LIMITATION IN THE INSTALLATION OF A SPLIT TYPE AC?

A.IT SHOULD BE LOCATED NEAR A WINDOWB. IT SHOULD NOT BE LOCATED NEAR THE FLOORC. ITS TUBE SHALL NOT EXCEED 3M FROM CONDENSER TO EVAPORATORD. ALL OF THE ABOVE3. WHERE WILL YOU FIND A CASSETTE TYPE AC?

A.WALLB. CEILINGC.FLOOR D. NEAR A WINDOW3. WHERE WILL YOU FIND A CASSETTE TYPE AC?

A.WALLB. CEILINGC.FLOOR D. NEAR A WINDOW4. WHAT IS THE SCIENCE OF LOWERING THE TEMPARATURE OF THE IMMEDIATE SURROUNDING?

A.DEHUMIDIFICATIONB. AIRCONDITIONC.REFRIGERATION D. HUMIDIFICATION4. WHAT IS THE SCIENCE OF LOWERING THE TEMPARATURE OF THE IMMEDIATE SURROUNDING?

A.DEHUMIDIFICATIONB. AIRCONDITIONC.REFRIGERATION D. HUMIDIFICATION5. WHAT IS THE ODORLESS AND COLORLESS GAS PRESENT IN AIR IN VARYING QUANTITY THAT AFFECTS RELATIVE HUMIDITY?

A.OXYGENB. HYDROGENC.STEAM D. WATER VAPOR5. WHAT IS THE ODORLESS AND COLORLESS GAS PRESENT IN AIR IN VARYING QUANTITY THAT AFFECTS RELATIVE HUMIDITY?

A.OXYGENB. HYDROGENC.STEAM D. WATER VAPOR6. WHAT DEVICE IS USED TO INCREASE THE PRESSURE OF REFRIGERANT IN AN AIRCON SYSTEM?

A.COMPRESSORB. EVAPORATORC.CONDENSER D. NONE OF THE ABOVE6. WHAT DEVICE IS USED TO INCREASE THE PRESSURE OF REFRIGERANT IN AN AIRCON SYSTEM?

A.COMPRESSORB. EVAPORATORC.CONDENSER D. NONE OF THE ABOVE7. WHERE WOULD YOU LOCATE A WINDOW TYPE ACU?

A. MIDDLE OF THE WALLB. TOP OF THE WALLC.BELOW THE WINDOW SILL D. ALIGNED WITH THE WINDOW SILL7. WHERE WOULD YOU LOCATE A WINDOW TYPE ACU?

A. MIDDLE OF THE WALLB. TOP OF THE WALLC.BELOW THE WINDOW SILL D. ALIGNED WITH THE WINDOW SILL8. FOR A SPRAWLING FACTORY, WHICH OF THE FOLLOWING IS AN APPROPRIATE ACU?

A. SPLIT TYPE ACUB. CHILLER TYPEC. INDUSTRIAL FAN D. WINDOW TYPE ACU8. FOR A SPRAWLING FACTORY, WHICH OF THE FOLLOWING IS AN APPROPRIATE ACU?

A. SPLIT TYPE ACUB. CHILLER TYPEC. INDUSTRIAL FAN D. WINDOW TYPE ACUFOR A MANAGERS OFFICE LOCATED AT THE CENTER OF THE FLOOR WHICH ACU IS MOST APPROPRIATE?

A. SPLIT TYPE ACUB. 1TR FLOOR MOUNTEDC. 5 TR FLOOR MOUNTEDD. CASSETTE TYPEFOR A MANAGERS OFFICE LOCATED AT THE CENTER OF THE FLOOR WHICH ACU IS MOST APPROPRIATE?

A. SPLIT TYPE ACUB. 1TR FLOOR MOUNTEDC. 5 TR FLOOR MOUNTEDD. CASSETTE TYPE10. WHICH AMONG THE CONSIDERATIONS WILL BEST INCREASE THE EFFICIENCY IN AIRCONDITIONING?

A. DECREASE FLOOR AREA B. DECREASE CEILING HEIGHTC. INCREASE MOUNTING HEIGHT OF ACUD. DECREASE SLOPE OF ROOF10. WHICH AMONG THE CONSIDERATIONS WILL BEST INCREASE THE EFFICIENCY IN AIRCONDITIONING?

A. DECREASE FLOOR AREA B. DECREASE CEILING HEIGHTC. INCREASE MOUNTING HEIGHT OF ACUD. DECREASE SLOPE OF ROOFIn an electric elevator, this cable provides electrical power to the car and the travel with the hoist.

A. GOVERNOR ROPEB. TRAVELLING CABLEC. CONVEYING CABLED. TRACTION CABLEIn an electric elevator, this cable provides electrical power to the car and the travel with the hoist.

A. GOVERNOR ROPEB. TRAVELLING CABLEC. CONVEYING CABLED. TRACTION CABLE12. THE CONNECTION BETWEEN CAR AND OPENINGS?

A. GOVERNOR B. TRAVELLING CABLEC. CONVEYORD. HOIST12. THE CONNECTION BETWEEN CAR AND OPENINGS?

A. GOVERNOR B. TRAVELLING CABLEC. CONVEYORD. HOIST13.A SMALL FREIGHT ELEVATOR DESIGNED TO CARRY OBJECTS RATHER THAT PEOPLE, IT IS OFTEN CONNECTED BETWEEN TWO FLOORS.

A. CONVEYORB. CARRIERC. DUMBWAITERD. MINI-ELEVATOR

13.A SMALL FREIGHT ELEVATOR DESIGNED TO CARRY OBJECTS RATHER THAT PEOPLE, IT IS OFTEN CONNECTED BETWEEN TWO FLOORS.

A. CONVEYORB. CARRIERC. DUMBWAITERD. MINI-ELEVATOR

14.WHO INVENTED THE FIRST SAFETY ELEVATOR BRAKES IN 1852

A. ELISHA GRAVES OTISB. CHARLES OTISC. NORTON OTISD. JASON GOODWIN

14.WHO INVENTED THE FIRST SAFETY ELEVATOR BRAKES IN 1852

A. ELISHA GRAVES OTISB. CHARLES OTISC. NORTON OTISD. JASON GOODWIN

15.WHAT IS THE MAIN PURPOSE OF A WALKALATOR?

A. CONTROL FOOT TRAFFICB. CONVENIENCE OF PEDESTRIANC. AESTHETICSD. TO CARRY HEAVY LUGGAGES

15.WHAT IS THE MAIN PURPOSE OF A WALKALATOR?

A. CONTROL FOOT TRAFFICB. CONVENIENCE OF PEDESTRIANC. AESTHETICSD. TO CARRY HEAVY LUGGAGES

16. WHAT IS THE MAXIMUM SPEED OF ESCALATOR ?A. 90 FPMB. 120 FPMC. 125 FPMD. 150 FPM

16. WHAT IS THE MAXIMUM SPEED OF ESCALATOR ?A. 90 FPMB. 120 FPMC. 125 FPMD. 150 FPM

17. WHAT IS THE SLOPE OF AN ESCALATOR ?A. 25 DEGREESB. 30 DEGREESC. 45 DEGREESD. 38 DEGREES

17. WHAT IS THE SLOPE OF AN ESCALATOR ?A. 25 DEGREESB. 30 DEGREESC. 45 DEGREESD. 38 DEGREES

18. A BOX USED TO CONTAIN SPLICING OF ELECTRICAL WIRES USSUALLY INTENDED TO CONCEAL THEM FROM SIGHT AND DETER TAMPERING?A. UTILITY BOXB. CUT OUT BOXC. PULL BOXD. JUNCTION BOX

18. A BOX USED TO CONTAIN SPLICING OF ELECTRICAL WIRES USSUALLY INTENDED TO CONCEAL THEM FROM SIGHT AND DETER TAMPERING?A. UTILITY BOXB. CUT OUT BOXC. PULL BOXD. JUNCTION BOX

19. ELECTRICITY IS SUDDENLY DISRUPTED, BUT IT WAS IMMEDIATELY RESTORED BY STAND BY GENERATORS, WHAT WAS USED? A. DOUBLE THROW SWITCHB. MANUAL TRANSFER SWITCHC. AUTOMATIC TRANSFER SWITCHD. NONE OF THE ABOVE

19. ELECTRICITY IS SUDDENLY DISRUPTED, BUT IT WAS IMMEDIATELY RESTORED BY STAND BY GENERATORS, WHAT WAS USED? A. DOUBLE THROW SWITCHB. MANUAL TRANSFER SWITCHC. AUTOMATIC TRANSFER SWITCHD. NONE OF THE ABOVE

20. IT IS USUALLY INSTALLED IN KITCHEN AND TOILETS TO EXPEL ODORS

A. DUCTINGB. EXHAUST FANC. DEODORIZERD. MECHANICAL VENT

20. IT IS USUALLY INSTALLED IN KITCHEN AND TOILETS TO EXPEL ODORS

A. DUCTINGB. EXHAUST FANC. DEODORIZERD. MECHANICAL VENT

21. WHAT IS THE STANDARD POWER VOLTAGE DOES MERALCO PROVIDE?

A. 110 VB. 220 VC. 120 VD. 230 V

21. WHAT IS THE STANDARD POWER VOLTAGE DOES MERALCO PROVIDE?

A. 110 VB. 220 VC. 120 VD. 230 V

22. IF THE POWER SUPPLY PROVIDED FOR A SUBDIVISION IS NOT SUFFICIENT FOR THE POWER REQUIREMENTS OF THE HOUSEHOLDS, WHAT MUST BE PROVIDED BY THE DEVELOPERS?

A. GENERATORB. CHARGING STATIONC. TRANSFORMERSD. ATS

22. IF THE POWER SUPPLY PROVIDED FOR A SUBDIVISION IS NOT SUFFICIENT FOR THE POWER REQUIREMENTS OF THE HOUSEHOLDS, WHAT MUST BE PROVIDED BY THE DEVELOPERS?

A. GENERATORB. CHARGING STATIONC. TRANSFORMERSD. ATS

23.WHAT IS THWN?

A. THERMOPLASTIC HEAT/WIND RESISTANT NYLON COATEDB. THERMOPLASTIC HIGH HEAT/WATER RESISTANT NYLON COATEDC. THERMOPLASTIC HIGH HEAT/WIND RESISTANT NYLON COATEDD. THERMOPLASTIC HUMIDITY OF WIND RESISTANT NYLON COATED

23.WHAT IS THWN?

A. THERMOPLASTIC HEAT/WIND RESISTANT NYLON COATEDB. THERMOPLASTIC HIGH HEAT/WATER RESISTANT NYLON COATEDC. THERMOPLASTIC HIGH HEAT/WIND RESISTANT NYLON COATEDD. THERMOPLASTIC HUMIDITY OF WIND RESISTANT NYLON COATED

24.A TYPE OF ELECTRICAL WIRE SUITABLE DOR DRY AND DAMP LOCATIONS?

A. THERMOPLASTIC HIGH HEAT RESISTANT NYLON COATED

B. THERMOPLASTIC HIGH HEAT/MOISTURE RESISTANT NYLON COATEDC. THERMOPLASTIC HIGH HEAT/WATER RESISTANT NYLON COATEDD. THERMOPLASTIC HUMIDITY RESISTANT NYLON COATED

24.A TYPE OF ELECTRICAL WIRE SUITABLE DOR DRY AND DAMP LOCATIONS?

A. THERMOPLASTIC HIGH HEAT RESISTANT NYLON COATED

B. THERMOPLASTIC HIGH HEAT/MOISTURE RESISTANT NYLON COATEDC. THERMOPLASTIC HIGH HEAT/WATER RESISTANT NYLON COATEDD. THERMOPLASTIC HUMIDITY RESISTANT NYLON COATED

25. MODULAR CUBICLES ARE INSTALLED, HOW MANY OUTLETS PER CUBICLE WOULD YOU RECOMMEND IF UPS IS USED IN THE OFFICE? A. 0B.1C. 2D. 3

YOU WERE TASKED TO DESIGN A BPO CENTER OFFICE, THE MANAGER WANTED TO KEEP A CLOSE WATCH ON HIS STAFF

25. MODULAR CUBICLES ARE INSTALLED, HOW MANY OUTLETS PER CUBICLE WOULD YOU RECOMMEND IF UPS IS USED IN THE OFFICE? A. 0B.1C. 2D. 3

YOU WERE TASKED TO DESIGN A BPO CENTER OFFICE, THE MANAGER WANTED TO KEEP A CLOSE WATCH ON HIS STAFF

26. WHAT TYPE OF DEVICE WILL YOU USE TO AMPLIFY THE WIFI CONNECTION COMING FROM MAIN SERVERA. LANB.ROUTERC. PABXD. CCTV

26. WHAT TYPE OF DEVICE WILL YOU USE TO AMPLIFY THE WIFI CONNECTION COMING FROM MAIN SERVER

A. LANB.ROUTERC. PABXD. CCTV

27. WHAT WOULD YOU INSTALL IF MANAGER WANTS LOCAL PHONE CONNECTION AS WELL AS AN OUTSIDE LINE?A. LANB.ROUTERC. PABXD. CCTV

27. WHAT WOULD YOU INSTALL IF MANAGER WANTS LOCAL PHONE CONNECTION AS WELL AS AN OUTSIDE LINE?A. LANB.ROUTERC. PABXD. CCTV

28. WHAT TYPE OF LOCAL DATA SHARING DEVICE IS APPROPRIATE FOR THE OFFICE?A. LANB.ROUTERC. PABXD. CCTV

28. WHAT TYPE OF LOCAL DATA SHARING DEVICE IS APPROPRIATE FOR THE OFFICE?A. LANB.ROUTERC. PABXD. CCTV

30. WHAT COMMUNICATION SYSTEM IS USED TO LINK ONE OFFICE TO ANOTHER FOR A PRIVATE DIALOGUE?A. TELEPHONE ENTRY SYSTEMB.INTERCOM C. PABXD. CCTV

30. WHAT COMMUNICATION SYSTEM IS USED TO LINK ONE OFFICE TO ANOTHER FOR A PRIVATE DIALOGUE?A. TELEPHONE ENTRY SYSTEMB.INTERCOM C. PABXD. CCTV

31. WHICH IS A GOOD LIGHTING FOR CURVED CEILING WITH WAVY DESIGN?

A. INDIRECT LIGHTING B.DIRECT LIGHTINGC. DOWNLIGHTD. TRACK LIGHT

31. WHICH IS A GOOD LIGHTING FOR CURVED CEILING WITH WAVY DESIGN?

A. INDIRECT LIGHTING B.DIRECT LIGHTINGC. DOWNLIGHTD. TRACK LIGHT

32. WHAT TYPE OF SWITCH HAS A PILOT LAMPWHICH CAN BE SEEN IN THE DARK?

A. GLOW SWITCHB.GLOW IN THE DARKC. DIMMER SWITCHD. ILLIMINATED SWITCH

32. WHAT TYPE OF SWITCH HAS A PILOT LAMPWHICH CAN BE SEEN IN THE DARK?

A. GLOW SWITCHB.GLOW IN THE DARKC. DIMMER SWITCHD. ILLIMINATED SWITCH

33. WHICH TYPE OF LIGHTING IS BEST SUITED FOR OUTDOOR PARKING?

A. HIGH INTENSITY DISCB. INCANDESCENTC. METAL HALLIDED. LOW PRESSURE SODIUM

33. WHICH TYPE OF LIGHTING IS BEST SUITED FOR OUTDOOR PARKING?

A. HIGH INTENSITY DISCB. INCANDESCENTC. METAL HALLIDED. LOW PRESSURE SODIUM

34. WHAT TYPE OF LIGHTING IS GOOD FOR PRODUCTION AREA HAVING SOFFIT ON SUSPENDED SLAB

A. DOWNLIGHTB. TRACK LIGHTC. TROFFERD. DOME LIGHT

34. WHAT TYPE OF LIGHTING IS GOOD FOR PRODUCTION AREA HAVING SOFFIT ON SUSPENDED SLAB

A. DOWNLIGHTB. TRACK LIGHTC. TROFFERD. DOME LIGHT

35. WHAT IS USED TO INTENSIFY LIGHT?

A. DIFFUSERB. REFLECTORC. MIRRORD. NONE OF THE ABOVE

35. WHAT IS USED TO INTENSIFY LIGHT?

A. DIFFUSERB. REFLECTORC. MIRRORD. NONE OF THE ABOVE

36. WHAT LIGHTING IS USED FOR READING?

A. GENERAL LIGHTINGB. TASK LIGHTINGC. ACCENT LIGHTINGD. NONE OF THE ABOVE

36. WHAT LIGHTING IS USED FOR READING?

A. GENERAL LIGHTINGB. TASK LIGHTINGC. ACCENT LIGHTINGD. NONE OF THE ABOVE

38. WHAT LIGHTING IS USED TO CALL ATTENTION TO A PARTICULAR OBJECT OR FEATURE?

A. GENERAL LIGHTINGB. TASK LIGHTINGC. ACCENT LIGHTINGD. NONE OF THE ABOVE

38. WHAT LIGHTING IS USED TO CALL ATTENTION TO A PARTICULAR OBJECT OR FEATURE?

A. GENERAL LIGHTINGB. TASK LIGHTINGC. ACCENT LIGHTINGD. NONE OF THE ABOVE

39. WHAT IS THE BEST LIGHTING FOR A FACTORY CONSIDERING ITS EFFECT IN THE WORK ENVIRONMENT?

A. WARM LIGHTB. COOL LIGHTC. DAY LIGHTD. NONE OF THE ABOVE

39. WHAT IS THE BEST LIGHTING FOR A FACTORY CONSIDERING ITS EFFECT IN THE WORK ENVIRONMENT?

A. WARM LIGHTB. COOL LIGHTC. DAY LIGHTD. NONE OF THE ABOVE

40. WHAT TYPE OF LIGHT IS USED FOR AN OVAL TRACK AND STADIUM?

A. FLUORESCENT LIGHTB. LOW SODIUM LAMPC. METAL HALLIDED. MERCURY VAPOR LAMP

40. WHAT TYPE OF LIGHT IS USED FOR AN OVAL TRACK AND STADIUM?

A. FLUORESCENT LIGHTB. LOW SODIUM LAMPC. METAL HALLIDED. MERCURY VAPOR LAMP

41. WHAT IS THE BEST WAY TO REDUCE AIR-BORNE SOUND?

A. COVER THE SOURCEB. OPEN THE WINDOWSC. USE ABSORPTIVE MATERIALSD. RELOCATE THE BUILDING

41. WHAT IS THE BEST WAY TO REDUCE AIR-BORNE SOUND?

A. COVER THE SOURCEB. OPEN THE WINDOWSC. USE ABSORPTIVE MATERIALSD. RELOCATE THE BUILDING

42. WHICH AMONG THE CHOICES GIVEN IS THE BEST WAY TO PREVENT SOUND TRANSITION?

A.CAVITY WALLB. DOUBLE WALLC. DRYWALL WITH INSULATIOND. GYPSUM BOARD

42. WHICH AMONG THE CHOICES GIVEN IS THE BEST WAY TO PREVENT SOUND TRANSITION?

A.CAVITY WALLB. DOUBLE WALLC. DRYWALL WITH INSULATIOND. GYPSUM BOARD

43. FOR A MUSIC HALL WITH LOTS OF AUDIENCE, WHAT IS THE BEST FLOORING MATERIAL?A.VINYL TILESB. CERAMIC TILESC. WOOD PLANKSD. LAMINATED WOOD

43. FOR A MUSIC HALL WITH LOTS OF AUDIENCE, WHAT IS THE BEST FLOORING MATERIAL?A.VINYL TILESB. CERAMIC TILESC. WOOD PLANKSD. LAMINATED WOOD

44. WHICH DOES NOT AFFECT THE TRANSMISSION OF SOUND FROM ONE ROOM TO ANOTHER?

A.THICKNESS OF WALL B. AREA OF WALLC. SIZE OF ROOMD. MATERIAL OF WALL ON THE NEXT ROOM

44. WHICH DOES NOT AFFECT THE TRANSMISSION OF SOUND FROM ONE ROOM TO ANOTHER?

A.THICKNESS OF WALL B. AREA OF WALLC. SIZE OF ROOMD. MATERIAL OF WALL ON THE NEXT ROOM

45. WHAT FLOORING WILL BEST A MUSIC ROOM?

A. MARBLEB. TILESC. WOODD. CARPET

45. WHAT FLOORING WILL BEST A MUSIC ROOM?

A. MARBLEB. TILESC. WOODD. CARPET

46. WHICH IS NOT A GOOD PARTITION FOR A NOISY AND CROWDED SPACE?

A. TEXTURED MASONRYB. METAL WITH TEXTUREC. WOODD. SMOOTH GLASS

46. WHICH IS NOT A GOOD PARTITION FOR A NOISY AND CROWDED SPACE?

A. TEXTURED MASONRYB. METAL WITH TEXTUREC. WOODD. SMOOTH GLASS

47. A SHOWROOM WITH AN INDUSTRIAL LOOK IS HAVING PROBLEM WITH ACCOUSTICS, WHAT CAN YOU PROPOSE?A. INSTALL CURTAINSB. INSTALL ACOUSTIC CEILINGC. INSTALL CARPETD. INSTALL EGG CRATES

47. A SHOWROOM WITH AN INDUSTRIAL LOOK IS HAVING PROBLEM WITH ACCOUSTICS, WHAT CAN YOU PROPOSE?A. INSTALL CURTAINSB. INSTALL ACOUSTIC CEILINGC. INSTALL CARPETD. INSTALL EGG CRATES

48. AN INDIRECT LIGHTING DIRECTED UPWARD FROM AN INTERIOR CORNICE AT THE EDGE OF THE CEILING?

A. DIRECT LIGHTINGB. TRACK LIGHTINGC. COVE LIGHTINGD. GENERAL LIGHTING

48. AN INDIRECT LIGHTING DIRECTED UPWARD FROM AN INTERIOR CORNICE AT THE EDGE OF THE CEILING?

A. DIRECT LIGHTINGB. TRACK LIGHTINGC. COVE LIGHTINGD. GENERAL LIGHTING

49.THE MEASURE OF BRIGHTNESS OF LIGHT SOURCE TO THE LUMINOUS INTENSITY PER UNIT AREA OR SURFACE VIEWED FROM A GIVEN DIRECTION

A. LUMENB. LUMINANCEC. FOOT CANDLED. CONTRAST

49.THE MEASURE OF BRIGHTNESS OF LIGHT SOURCE TO THE LUMINOUS INTENSITY PER UNIT AREA OR SURFACE VIEWED FROM A GIVEN DIRECTION

A. LUMENB. LUMINANCEC. FOOT CANDLED. CONTRAST

50.TYPE OF LIGHTING THAT CONTAINS MERCURY, IT IS ACTUALLY GAS-DISCHARGED LAMP THAT USES ELECTRICITY.

A. INCANDESCENT BULBB. CFLC. FLUORESCENT LAMPD. LED LIGHT

50.TYPE OF LIGHTING THAT CONTAINS MERCURY, IT IS ACTUALLY GAS-DISCHARGED LAMP THAT USES ELECTRICITY.

A. INCANDESCENT BULBB. CFLC. FLUORESCENT LAMPD. LED LIGHT

END