ac-20 multi point actuator - southco.com · 263c dimensions in millimeters (inch) unless otherwise...
TRANSCRIPT
263B
Dimensions in millimeters (inch) unless otherwise stated
ACTUAL SIZE • Single or multi-pointactuation capability
• Compatible with a widerange of rotary latches
• Environmentally sealed
Material and FinishHousing: Glass-filled nylon, black
Paddle: Zinc alloy, black powder coated or chrome plated
Installation NotesMaximum tightening torque on supplied mounting nuts 3 Nm (27 inlbf)
NotesFor lock core selection and a complete overview of the SOUTHCO®
Key-Choice System see page 158
Can be configured with 1 or 2 cables, see page 272. Recommended cable type 7
Part NumberSee table
AC-20 Multi Point ActuatorPull-to-open Paddle
www.southco.com/AC
Other options available. For complete details on variety, part numbers, installation and
specification, go to
51.1(2.01)
27.3(.68)
29.6(1.17)
29.6(1.17)
17.3(.68)
170(6.7)
119(4.7)
93.7(3.69)
6.4 (.25)
95.2(3.75)
18.2(.72)4X Ø 5.2 ± 0.1
(.210 ±.005)
80.9(3.19)
131.7(5.18)
52(2.05)
12.62(.50)
AC - 20 - 3 L 1 - PP - KC
KC Key Codes (Omit for Locking Options 1, 2, 4, 5 and 9) *KD10 Keyed Differently (Only used if L =3 or 6) *MK10 Master Keyed Differently (Only used if L =6)
* Supplied in multiples of 10 with 10 different key codes.
L Locking Options1 Reversible Key (No Keys - R001) 2 Reversible Key (2 Keys included - R001) 3 Reversible Key (Keyed differently - 2 keys included)4 Standard Key (No keys - CH751)5 Standard Key (2 Keys included - CH751)6 Standard Key (Keyed differently - 2 keys included)9 No Lock Plug installed (See notes for more information)
PP Paddle Finish 30 Chrome, polished50 Black powder coated
51.1(2.01)
27.3(.68)
29.6(1.17)
Cable B
Cable A
29.6(1.17)
17.3(.68)
170(6.7)
119(4.7)
93.7(3.69)
6.4 (.25)
95.2(3.75)
18.2(.72)4X Ø 5.2 ± 0.1
(.210 ±.005)
80.9(3.19)
131.7(5.18)
52(2.05)
12.62(.50)
Panel Preparation
29.6(1.17)
17.3(.68)
170(6.7)
119(4.7)
93.7(3.69)
6.4 (.25)
95.2(3.75)
18.2(.72)4X Ø 5.2 ± 0.1
(.210 ±.005)
80.9(3.19)
131.7(5.18)
52(2.05)
12.62(.50)
Maximum Door Thickness - 8 (.32)
263C
Dimensions in millimeters (inch) unless otherwise stated
• Single or multi-pointactuation capability
• Compatible with a wide range of rotary latches• Environmentally sealed
Material and FinishLatch assembly: Zinc alloy, black or white powder coated or chrome plated. Mounting bracket: Steel, zinc plated
Installation NotesMaximum tightening torque on mounting screws: 2 N•m (14 in•lbf)
NotesFor lock core selection and a complete overview of the SOUTHCO®
Key-Choice System see page 158
Can be configured with 1 or 2 cables. Recommended cable type 7. Cable mounting brackets soldseparately. (See page 275).
Part NumberOrder latch, bracket and mounting screws separately
For latch see table
For mounting bracket, order part number R3-23-161-11
See table for mounting screws
www.southco.com/AC
R3-22 Multi Point ActuatorPull-to-open Paddle
Other options available. For complete details on variety, part numbers, installation and
specification, go to
Screws for Mounting Bracket Part Number R3-23-161-11
Front Door Thickness No. 8 Self Tapping Screw (order 4 per latch)
1.5 (.062) - 4.8 (.187) R3-23-250-01
4.8 (.187) - 9.5 (.375) R3-23-250-02
Panel Preparation
Mounting bracket
(sold separately)
100 (3.94)
118 (4.65)
100 (3.94)
85(3.35)
9(.35)
118(4.65)
2X 16.5 (.65)
1.5-9.5(.0625-.375)
118 (4.65)
32-50(1.26-2.00)
Backside panel of door
Frontside panel of door
Backside panel
Backside panel
116(4.57)
18.2(.72)
128.7 (5.07)
22-50 (.875-2.00)
32-50 (1.25-2.00)
Frontflange
Front flange
Multi-pointcables (not supplied)
68.5(2.7)
110(4.3)
71(2.8)
102(4)
Mounting bracket
R3-23-161-11
(sold separately)
Cable retaining
clips included
Mounting screws (4x) see table below
(sold separately)
R3 - 22 - 3 L 0 - F 0
F Finish1 Polished chrome 5 Black powder coated 7 White powder coated
L Locking Options0 Non-locking 1 Reversible Key (No keys - R001) 2 Reversible Key (2 keys included - R001)4 Standard Key (No keys - CH751)5 Standard Key (2 Keys included - CH751)9 No lock plug installed (see notes for more information)
264
Dimensions in millimeters (inch) unless otherwise stated
AC - 10 - S L 1 - 11 - KC
ACTU
ALSI
ZE
www.southco.com/AC
AC-10 ActuatorLarge handle • Flush mount
• Rear mount installation• Flush mounting style• Single, multi-point or direct
pull actuation capability• Multiple key code options• Non-Locking option• Electronic lock/unlock option
Material and FinishHousing, handle, rotating linkage: glass-filled nylon, black
Threaded stud and cable bracket retainers: steel, zinc nickel
Housing and handle gaskets: adhesive backed foam, black
Installation NotesMounting nut (M6 x 1) not supplied. Installation torque of mounting nuts not to exceed 7 N•m (62 in-lbf)
NotesAC-10 can only use snub end coupling (Type 6 or 7 cable).
Electronic Actuator Operating InformationVoltage: 12 V ±1.2 V
Current: 2.5 A - 3 A
Pulse Duration: 225 ms ±25 ms
Notes: For use with Rods / Cables, recommended Snap-in Retainer for Rotator Plate: Southco Part Number R4-0-43922. See Trade Drawing J-R4-0-43922 for more details and options.
For lock core selection, detailed key information and a complete overview of the SOUTHCO® Key-Choice System see PK Lock Cores section.
For unique key code options, please contact customer service.
KC Key Codes (Omit for Locking Options 0, 1, 2, 4, 5 and 9) *KD10 Keyed Differently (Only used if L =3 or 6) *MK10 Master Keyed Differently (Only used if L =6)
* Supplied in multiples of 10 with 10 different key codes.
S Actuation Style1 Single Point, Direct Pull 2 Multi-Point, without Cable Bracket 3 Multi-Point, with Cable Bracket
L Locking Options0 Non-Locking 1 Reversible key (No keys - R001) 2 Reversible key (2 keys included - R001) 3 Reversible key (keyed differently - 2 keys included) 4 Standard key (No keys - CH751) 5 Standard key (2 keys included - CH751) 6 Standard key (keyed differently - 2 keys included)7 Reversible Key (2 keys included - 14603) 9 No Lock Plug installed (See notes for more information)
131.1(5.16)
21.5 (.85)
48.9(1.93)
43.5(1.71)
211.3 (8.32)
M6 x 20 (4)
137.4(5.41)
12X R4(.16)
23.1(.91)
32.2(1.27)
72(2.84)
4X Ø7 ±0.1
86 ±0.3(3.39 ±.012)
152.4 ±0.3(6 ±.01)
101(3.98)
14(.551)
• Recommended to use with Trigger Pull
• Recommended to use with Rods
• Recommended to use with Cables: see AC Cable drawing J-AC-C for cable selection.
Part Number
Trigger Pull R4-0-51292
218 (8.6) 120 (4.7)
34(1.3)
84(3.3)
55(2.2)
120 (4.7)3X Ø 7 (.3)
34(1.34)
16(.6)
35(1.4)
105(4.1)
38.1(1.50) 29.8
(1.17)
2.9 (.11)
65(2.5)
Direct Pull
Multi-Point Without Cable Bracket
Panel Preparation
Multi-Point With Cable Bracket
Part Number Selection _______________________________________________________________________________
Multi-Point With Cable Bracket andLock/Unlock Electronic Actuator
• Recommended to use with Cables: see AC Cable drawing J-AC-C for cable selection.
EM-3 Multi-Point, with Cable Bracket and Electronic Lock/Unlock
MaximumPanel Thickness
264A
Dimensions in millimeters (inch) unless otherwise stated
218 (8.6) 120 (4.7)
34(1.3)
84(3.3)
55(2.2)
120 (4.7)3X Ø 7 (.3)
34(1.34)
16(.6)
35(1.4)
105(4.1)
38.1(1.50) 29.8
(1.17)
2.9 (.11)
65(2.5)
AC-11 ActuatorLarge Handle • Flush Mount
www.southco.com/AC
• Rear mount installation• Flush mounting style• Single, multi-point or direct pull actuation• Multiple key code options• Non-locking option
Material and FinishHousing, handle, linkage: glass-filled nylon, black
Threaded stud and cable bracket retainers: steel, zinc nickel plated
Housing and handle gaskets: Adhesive backed foam, black
Installation NotesMounting nut (M6 x 1) not supplied. Installation torque of mounting nuts not to exceed 7 N•m (62 in-lbf)
NotesAC-11 can only use snub end coupling (Type 6 or 7 cable).
___________________________________________________________________________ Part Number SelectionNotes: For use with Rods / Cables, recommended Snap-in Retainer for Rotator Plate: Southco Part Number R4-0-43922. See Trade Drawing J-R4-0-43922 for more details and options.
For lock core selection, detailed key information and a complete overview of the SOUTHCO® Key-Choice System see PK Lock Cores section.
For unique key code options, please contact customer service.
Other options available. For complete details on variety, part numbers, installation and specification, go to
AC - 11 - S L 1 - 11 - KC
KC Key Codes (Omit for Locking Options 0, 1, 2, 4, 5 and 9) *KD10 Keyed Differently (Only used if L =3 or 6) *MK10 Master Keyed Differently (Only used if L =6)
* Supplied in multiples of 10 with 10 different key codes.
S Actuation Style1 Single Point, Direct Pull 2 Multi-Point, without Cable Bracket 3 Multi-Point, with Cable Bracket
L Locking Options0 Non-Locking 1 Reversible key (No keys - R001) 2 Reversible key (2 keys included - R001) 3 Reversible key (keyed differently - 2 keys included) 4 Standard key (No keys - CH751) 5 Standard key (2 keys included - CH751) 6 Standard key (keyed differently - 2 keys included)7 Reversible Key (2 keys included - 14603) 9 No Lock Plug installed (See notes for more information)
140 ±0.3(5.512 ±.005) 4X Ø7
(.276)
56(2.205)
103(4.055)
125(4.921)
197.7(7.783)
4X R4(.157)8X R18(.709)
70 ±0.3(2.756 ±.005)
14(.551)
211.3 (8.32)
131.1(5.16)
43.6(1.72)
21.1(.83)
50(1.97)
• Recommended to use with Trigger Pull
• Recommended to use with Rods
• Recommended to use with Cables: see AC Cable drawing J-AC-C for cable selection.
Part Number
Trigger Pull R4-0-51292
Direct Pull
Multi-Point Without Cable Bracket
Panel PreparationMulti-Point With Cable Bracket
140 ±0.3(5.512 ±.005) 4X Ø7
(.276)
56(2.205)
103(4.055)
125(4.921)
197.7(7.783)
4X R4(.157)8X R18(.709)
70 ±0.3(2.756 ±.005)
14(.551)
211.3 (8.32)
131.1(5.16)
43.6(1.72)
21.1(.83)
50(1.97)
Trigger pull
(order seperately)
Maximum Panel Thickness
265
Dimensions in millimeters (inch) unless otherwise stated
AC - 15 - 1 L 1 - 11 - KC
ACTU
AL S
IZE
AC-15 ActuatorLarge Handle • Surface Mount
www.southco.com/AC
• Rear mount installation• Surface mounting style• Direct pull actuation• Multiple key code options• Non-locking option
Material and FinishHousing, handle, linkage: glass-filled reinforced nylon, black
Threaded inserts: brass, natural
Housing and handle gaskets: adhesive backed foam, black
Installation NotesMounting hardware (M6 x 1) not supplied. Recommended screw length=panel thickness + 10.0 (.39) Installation torque of mounting nuts not to exceed 7 N•m (62 in-lbf)
___________________________________________________________________________ Part Number Selection
218 (8.6) 120 (4.7)
34(1.3)
84(3.3)
55(2.2)
120 (4.7)3X Ø 7 (.3)
34(1.34)
16(.6)
35(1.4)
105(4.1)
38.1(1.50) 29.8
(1.17)
2.9 (.11)
65(2.5)
218 (8.6) 120 (4.7)
34(1.3)
84(3.3)
55(2.2)
120 (4.7)3X Ø 7 (.3)
34(1.34)
16(.6)
35(1.4)
105(4.1)
38.1(1.50) 29.8
(1.17)
2.9 (.11)
65(2.5)
218 (8.6) 120 (4.7)
34(1.3)
84(3.3)
55(2.2)
120 (4.7)3X Ø 7 (.3)
34(1.34)
16(.6)
35(1.4)
105(4.1)
38.1(1.50) 29.8
(1.17)
2.9 (.11)
65(2.5)
KC Key Codes (Omit for Locking Options 0, 1, 2, 4, 5 and 9) *KD10 Keyed Differently (Only used if L =3 or 6) *MK10 Master Keyed Differently (Only used if L =6)
* Supplied in multiples of 10 with 10 different key codes.
L Locking Options0 Non-Locking 1 Reversible key (No keys - R001) 2 Reversible key (2 keys included - R001) 3 Reversible key (keyed differently - 2 keys included) 4 Standard key (No keys - CH751) 5 Standard key (2 keys included - CH751) 6 Standard key (keyed differently - 2 keys included) 9 No Lock Plug installed (See notes for more information)
Part Number
Trigger Pull R4-0-51292
Notes:For lock core selection, detailed key information and a complete overview of the SOUTHCO® Key-Choice System see PK Lock Cores section.
For unique key code options, please contact Southco.
Trigger PullActuator is recommended to use with Trigger Pull
Panel Preparation
Other options available. For complete details on variety, part numbers, installation and specification, go to
266
Dimensions in millimeters (inch) unless otherwise stated
AC - 30 - E L M - H B - KC
ACTUALSIZE
L Locking Option1 Reversible key (No keys - R001)2 Reversible key (2 keys included - R001)3 Reversible key (Multiple key codes - 2 keys included)4 Standard key (No keys - CH751)5 Standard key (2 keys included - CH751)6 Standard key (Multiple key codes - 2 keys included)
M Mounting Method1 With spacer mounting (must have if glass panel)2 Without spacer mounting
E End Style1 With Cam attached 3 Without Cam attachment
B Button Material1 Nylon, black
H Housing Material1 Zinc alloy with black powder coat3 Stainless steel with black powder coat
K Key Codes(Omit for locking options 1,2,4 and 5)KD10 Keyed differently (10 codes)MK10 Master keyed, keyed differently
Other options available. For complete details on variety, part numbers, installation and specification, go to
10 (.39) Cam/Cable Travel
Ø 38.3(1.51)
2 (.08)
Ø4.1 (.16)
28(1.10)
64(2.52)
2 X Ø5 ±0.1(.197 ±.004)
Spacer not required if panel thickness > 10.3 (.41)
Tab washerMounting nut
Panel Thicknessfrom 1 to 22(.04 to .87) Max
Push Travel 12 (.47)
28(1.10)
Ø 32 .4 (1.27 )+ 0.2- 0
+.008- 0
29.2 (1.15 )
Panel preparation
+ 0.2- 0
+.008- 0
42(1.65)Push Down
12 (.47)
51.4(2.02)
Cable holder
AC-30 Multi Point ActuatorPush-Button
• Single or multi-point actuation capability• Accommodates wide panel thickness• Multiple key code options• Single hole install
Material and FinishButton: Nylon Housing: Zinc or Stainless steel Lock Plug: Zinc Cam, Washer, Rivet: Stainless steel, passivated
www.southco.com/AC
Part Number Selection _______________________________________________________________________________
With cam attachment shown
Without cam attachment shown
267
Dimensions in millimeters (inch) unless otherwise stated
AC - 40 - E L M - H B - KC
ACTUAL SIZE
Other options available. For complete details on variety, part numbers, installation and specification, go to
181.4(7.14)
47(1.85)34
(1.34)
Outer SealSpacer
E-Ring
Cable Holder
Metal Nut
Tab Washer
Cam/CableTravel 10 (.39)
Ø 4.1 (.16)51.4(2.02)
58(2.28)
34(1.34)
Panel Thickness from 1 to 16.8 (.04 to .66) Max.
142 ±1(5.59 ±.02)
142 ±1(5.59 ±.02)
13 ±0.2 (.510±.008)
8.4 ±0.1 (.33 ±.004)
Ø 32.4 (1.27 )
+ 0.2-0
+ .008-0
Ø44 (1.73)
M8 X 1.25 (.05) thread18 deep
(Max mounting torque: 40 (1.57) N·M)12 (.47) Push Down
36(1.42)
43(1.34)
Spacer not required if panel thickness > 4.6 (.18)
2 X Ø5 ±0.1(.197 ±.004)
181.4(7.14)
47(1.85)34
(1.34)
Outer SealSpacer
E-Ring
Cable Holder
Metal Nut
Tab Washer
Cam/CableTravel 10 (.39)
Ø 4.1 (.16)51.4(2.02)
58(2.28)
34(1.34)
Panel Thickness from 1 to 16.8 (.04 to .66) Max.
142 ±1(5.59 ±.02)
142 ±1(5.59 ±.02)
13 ±0.2 (.510±.008)
8.4 ±0.1 (.33 ±.004)
Ø 32.4 (1.27 )
+ 0.2-0
+ .008-0
Ø44 (1.73)
M8 X 1.25 (.05) thread18 deep
(Max mounting torque: 40 (1.57) N·M)12 (.47) Push Down
36(1.42)
43(1.34)
Spacer not required if panel thickness > 4.6 (.18)
2 X Ø5 ±0.1(.197 ±.004)
AC-40 Multi Point ActuatorPush-Button Handle
• Single or multi-point actuation capability• Accommodates wide panel thickness• Multiple key code options• Easy Grip
Material and FinishButton: Nylon Housing: Zinc Alloy or Stainless steel Lock plug: Zinc Alloy Cam, Washer, Rivet: Stainless steel, passivated
www.southco.com/AC
With cam attachment shown
Without cam attachment shown
L Locking Option1 Reversible key (No keys - R001)2 Reversible key (2 keys included - R001)3 Reversible key (Multiple key codes - 2 keys included)4 Standard key (No keys - CH751)5 Standard key (2 keys included - CH751)6 Standard key (Multiple key codes - 2 keys included)
M Mounting Method1 Cable parallel (or no cable), with spacer mounting (must have if glass panel)2 Cable parallel (or no cable), without spacer mounting3 Cable cross with spacer mounting (must have if glass panel)4 Cable cross without spacer mounting
E End Style1 With Cam attached 3 Without Cam attachment
B Button Material1 Nylon, black
H Handle Material1 Black GF nylon with zinc housing insert2 Black GF nylon with stainless steel housing insert
___________________________________________________________________________ Part Number Selection
K Key Codes(Omit for locking options 1,2,4 and 5)KD10 Keyed differently (10 codes)MK10 Master keyed, keyed differently
268
Dimensions in millimeters (inch) unless otherwise stated
Other options available. For complete details on variety, part numbers, installation and specification, go to
ACTUAL SIZE
ACTUAL SIZE
Pull direction
45 (1.77) HousingT-handle
60 (2.36)
104.5 (4.11)117 Open (4.61)
25±0.2(.98±.008)
40±0.2 (1.57±.008)
4 x Ø 4.5±0.1 (.18±.004)
(For thru hole mounting)
56(2.20)
Cable clip 20.8 (.82)
21.7(.85)
23(.91)
108.3 (4.26) Panel
Panel thickness
Cable placement 1
5.7(.22)
38.3 (1.51)
53.7(2.11)
28.7(1.13)
80±0.3 (3.15±.012) 2 x Ø 4.5±0.1
(.177±.004)(For thru hole mounting)
91.6±0.3 (3.61±.012)5.8±0.1 (.23±.004)
42±0.5(1.65±.02)21±0.2
(.83±.008)
4 x R5 (.2) Maximum
Cable placement 2
Part Number
AC-60-101-11
Part Number
AC-70-101-11
Cable Orientation Panel Thickness Cable Travel
Placement 1 12.5 (.49) maximum 11.1 (.44)
Placement 2 16 (.63) maximum 13.2 (.52)
• Surface mount installation• Generous grip area• Pull to activate
Material and FinishHousing: PC/ABS, black T-handle and slide: Glass-filled nylon, black Clip: Acetal, black Spring: Stainless steel, passivated Part NumberSee table
AC Single Point ActuatorT-handle
AC Single Point ActuatorPlastic paddle and housing
www.southco.com/AC
• Front mount installation• Flush• Two cable mounting options
Material and FinishPaddle and housing: Glass-filled nylon, black Spring: Stainless steel, passivated
Part NumberSee table
www.southco.com/AC
269
Dimensions in millimeters (inch) unless otherwise stated
Other options available. For complete details on variety, part numbers, installation and specification, go to
ACTUAL SIZE
ACTUALSIZE
Knob Ø 26 (1.02) 6 (.24)
64.6(2.54)
Door panel
Mounting nut
Housing
26 (1.02)Maximum panel thickness
Cam
Ø 32(1.26 )
+1-0
30±0.2(1.18±.008)
Double-D holepreparation
+.04-0
13.7 (.54) Cable travel
Ø 38 (1.50)
Part Number
AC-80-101-11
AC Single Point ActuatorPush-button
• Flush• Mounting hardware included
Material and FinishPush button and housing: PC/ABS, black Cam: Glass-filled nylon, black Spring: Stainless steel, passivated
Part NumberSee table
www.southco.com/AC
AC Single Point ActuatorAluminum paddle and housing
www.southco.com/R4
• Front mount installation• Three cable mounting options• Low profile• Robust material
Material and FinishPaddle and housing: Aluminum, black powder coated
NotesAC-75 can only use snub end coupling (Type 6 or 7 cable).
Part Number
AC-75-101-11
Cable Orientation Panel Thickness Cable Travel
Placement 1 12.5 (.49) max. 11.1 (.44)
Placement 2 16 (.63) max. 13.2 (.52)
Placement 3 16 (.63) max. 13.2 (.52)
Part NumberSee table
49.2(1.94)
13(0.51)
96.2(3.78)
30.3(1.2)
Cable Placement 3
CablePlacement 2
CablePlacement 1
81(3.2)
38.9(1.53)
18.9 (0.74)
4X R5 Max
Door
2X Ø 4.5 ±0.1(.177±.004)(For thru hole mounting)
73 (2.87)
4 ±0.1 (0.15 ±0.003)
35.2(1.38)
35.9(1.41)
49.2(1.94)
13(0.51)
96.2(3.78)
30.3(1.2)
Cable Placement 3
CablePlacement 2
CablePlacement 1
81(3.2)
38.9(1.53)
18.9 (0.74)
4X R5 Max
Door
2X Ø 4.5 ±0.1(.177±.004)(For thru hole mounting)
73 (2.87)
4 ±0.1 (0.15 ±0.003)
35.2(1.38)
35.9(1.41)
270
Dimensions in millimeters (inch) unless otherwise stated
ACTUAL SIZE
Other options available. For complete details on variety, part numbers, installation and specification, go to
AC-50 Single Point ActuatorSqueeze handle
• Single actuation capability• Accomodates tubular
construction or rounded mounting surfaces
Material and FinishHousing, handle: Glass-filled nylon, black
Installation NotesInstallation torque of screws not to exceed 2 N•m maximum (Countersunk screws or rivets recommended)
www.southco.com/AC
Part Number
AC-50-101-11
Squeeze Handle
Panel Preparation
161.4(6.35)
4.5(.18)
15.221.7
129.5
141.4
18
6.7
44(1.73)
28.2(1.11)
R 13.4(.53) 20
(.8)
2X M5 Thread
Use Southco cable end fitting type B (L type)(Cable sold separately. Refer to Southco drawingJ-AC-C for Cable Selection Guide.)
Squeeze handleassembly
Customer installation tube
169.2 28.2
20
R 13.4
44
4.5
13 Handle travel
12 Cable travelRetaining
clip included
Pull Direction
Use Southco cable end fitting type B (L type)(Cable sold separately. Refer to Southco drawingJ-AC-C for Cable Selection Guide.)
Squeeze handleassembly
Customer installation tube
169.2 28.2
20
R 13.4
44
4.5
13 Handle travel
12 Cable travelRetaining
clip included
Pull Direction
271
Dimensions in millimeters (inch) unless otherwise stated
38mm (1.5”)Shown actual size
50mm (2”)Shown actual size
AC Single Point ActuatorsStainless Steel · M1 Style Actuator
CablesConstructed from marine grade stainless materials, the cable is suitable for multiple bends and can be further customized upon request.
• Single, round-hole installation
• Locking style restricts access
• Premium finish and corrosion resistance
Material and FinishLatch: 316 grade stainless steel, bright polished Spacer: Nylon, black Contact Southco for other finishes
Performance DetailsMax. static load: 545 N (122 lbf)
Accessories - 38mm (1.5”)Spacer: M1-510-96-1 Mounting screws: M1-510-96-4
One key supplied per latch for additional keys order M7-88-9121324-S
Accessories - 50mm (2”)For lock style 4 Key (pair) Part number: M1-546
For lock style 7 Overmolded key S008 (pair) Part number: M1-525-39-S008
Other options available. For complete details on variety, part numbers, installation and specification, go to
www.southco.com/AC
ACTUAL SIZE
ACTUAL SIZEØ 61
(2.41)
Locking handle shown(also available as non-locking)
Ø 44(1.73)
ACTUAL SIZE
ACTUAL SIZEØ 61
(2.41)
Locking handle shown(also available as non-locking)
Ø 44(1.73)
Size Actuator Assembly Part Number Door
ThicknessCable Mounting
Bracket
38mm (1.5)
Locking (2 keys supplied)
AC-M1-15-41-89 mm R4-0-50253-1
12 mm R4-0-50253-2
Non-Locking AC-M1-15-61-89 mm R4-0-50253-1
12 mm R4-0-50253-2
50mm(2)
Locking (2 keys supplied)
AC-M1-42-8 9 mm R4-0-50253-1
AC-M1-43-8 12 mm R4-0-50253-2
Non-LockingAC-M1-62-8 9 mm R4-0-50253-1
AC-M1-63-8 12 mm R4-0-50253-2
Key-Locking keyed alike S008
AC-M1-72-8 9 mm R4-0-50253-1
AC-M1-73-8 12 mm R4-0-50253-2
Ø38.1 ±0.5 (1.50 ±.02) Ø50 (2.00 )+ 1.2
- 0+ .015- .031
Ø 44(1.73)
Cable travel 13 (.5)
Cable travel 13 (.5) Cable retainer (Sold separately)See table (Mounting screw not included)
Ø 61(2.41)
2.5 (.10) Small Version3 (.12) Large Version
Door thickness (See part number builder)
34(1.34)
Door
Door
Door thickness (See part number builder)
Cable Mounting Bracket
34(1.34)
Actuator Assembly (38mm (1.5) shown)
Retainer Clip (Sold separately) R4-0-43922-2
Cable mounting bracket (Sold separately) See page 275 (1/8” Mounting screws not included)
Phillips Recess Pan Head Mounting Screws (included)
Mounting Bracket
38mm (1.5)50mm (2)
13 (.5)
2.5 (.10)3 (.12)
34(1.34)
Cable Mounting Bracket
Cable Travel
Door
Door Thickness
38mm (1.5)50mm (2)
271A
Dimensions in millimeters (inch) unless otherwise stated
64 - 40 - 4 L H - M
ACTUAL SIZE
www.southco.com/64
108 (4.25)
139.7 (5.50)
23(.91)
1.2(.05)
40.9 (1.61)
12(.45)
3(.13)
Ø 6.3(.25)
Ø 2.3(.09)
47 (1.85) Unlatched
70 (2.75)Latched
29 (1.14)Latched
25 (1.0) Unlatched
4 x Ø rivet mounting onlyH
Available with or without lock (see part number selection)
4 x R 5 (.20)Maximum
4 x ØRivet mounting only
Door
96.8(3.81)
86(3.38)
118 (4.65)95.2 (3.75)
H
64 Push-to-Close ActuatorPull-to-open · Paddle handle actuator · Multi-point · Large
Part Number Selection _______________________________________________________________________________
• Flush mounting installation• Multiple mounting styles• Locking and Non-Locking options
Material and FinishStainless steel, polished, steel, zinc plated or black powder coated
AccessoriesFlat key, keyed alike CH751 (2 keys per ring) Part number: PK-10-01
Overmolded key, keyed alike CH751 (2 keys per ring) Part number: PK-10-01-05
NotesAC Cable end fitting must be eyelet for this actuator (Page 272)
H Housing0 Weld1 Rivet through hole 4.9 (.19)2 Rivet through hole 5.2 (.20)
L Lock style0 Non-locking1 Key-locking keyed alike CH751 (2 Flat keys supplied)
M Material10 Steel, zinc plated 20 Stainless steel, polished50 Steel, black powder coated
Other options available. For complete details on variety, part numbers, installation and specification, go to
(2 PL) For use with AC Cables, must use eyelet fitting. Use cotter pin to secure end fitting.
271B
Dimensions in millimeters (inch) unless otherwise stated
PULL
PULL
15 (.59)
30(1.18)
97(3.82)
110(4.31)
54.2(2.15)
23.4(.92)
115(4.53)
ø 4.5(.18)
4.5 (.18) dia x 3
• Allows one actuation point for two rotary latches or two actuation points for one rotary latch
• Adjustable to fine tune timing of actuation points• Cable splitter and cables sold separately
Material and FinishHousing: Black Polypropylene Slider: Black Glass-filled nylon
See page 272 and 273 for cable end fitting and cable type
Part Number
AC-05-301-11
One actuation point for two rotary latches
Packaged Delivery Condition After customer assembly
Two actuation points for one rotary latch
AC Cable Splitter
optional locking screw point - use PT K60 screw not supplied
Cables shown for illustration only - to be ordered separately
Clips detached from slider and installed to secure cables.
Latches Latch
Actuator Actuators
Other options available. For complete details on variety, part numbers, installation and specification, go to
www.southco.com/AC
PULL
PULL
PULL
PULL
ACTUAL SIZE
275
Dimensions in millimeters (inch) unless otherwise stated
AC CablesCable Accessories
Part Number A
R4-0-50253-1 31 (1.22)
R4-0-50253-2 28 (1.10)
R4-0-50253-3 19 (.75)
LatchSeries
Trigger / Lever Type
PartNumber
Color B C D ETrigger /
Lever Hole Diameter
Trigger / Lever
Thickness
R4-05 Bottom R4-0-60784 Beige5.9
(.23)3.5
(.13)16.4 (.65)
2.8 (.11)
6.4 (.25)
3 (.12)
R4-10
PerpendicularIn-line
Two Point
R4-0-43922 Black 5.9 (.23)
2.5 (.10)
14.4 (.57)
4.3 (.17)
6.3 (.25)
2 (.08)R4-0-43922-3 Red
Bottom / Top R4-0-43922-2 Black5.9
(.23)4.5
(.18)16.4 (.65)
4.3 (.17)
6.3 (.25)
4(.16)
Dual Trigger
R4-0-43922 Black 5.9 (.23)
2.5 (.10)
14.4 (.57)
4.3 (.17)
6.3 (.25)
2 (.08)R4-0-43922-3 Red
R4-0-43922-2 Black5.9
(.23)4.5
(.18)16.4 (.65)
4.3 (.17)
6.3 (.25)
4(.16)
R4-30
PerpendicularTwo Point
R4-0-43922 Black 5.9 (.23)
2.5 (.10)
14.4 (.57)
4.3 (.17)
6.3 (.25)
2 (.08)R4-0-43922-3 Red
Bottom R4-0-43922-2 Black5.9
(.23)4.5
(.18)16.4 (.65)
4.3 (.17)
6.3 (.25)
4(.16)
R4-20 BottomR4-0-43922-1 White
6.3 (.25)
4.5 (.18)
16.4 (.65)
4.3 (.17)
6.7 (.26)
4 (.16)R4-50 Perpendicular
• For use with Ø 4 (.157) rod or Southco cable assembly
Material and FinishClip: Acetal
Bracket: Steel
Part NumberSee table
Retainer Clip
Cable Mounting Bracket
A
1.9 (.07) 28.1(1.11)
www.southco.com/C3
Other options available. For complete details on variety, part numbers, installation and specification, go to
DC
Ø B
E
Mounting Bracket
Retainer Clip
Actuator Assembly
Mounting Screws
Cable Mounting Bracket(1/8” Mounting screws not included)