abridged specifications: 10ds3111e/a sensor with 50sm1000
TRANSCRIPT
![Page 1: Abridged Specifications: 10DS3111E/A Sensor with 50SM1000](https://reader031.vdocuments.us/reader031/viewer/2022021009/6203a9ccda24ad121e4c04f9/html5/thumbnails/1.jpg)
Complete product specifications and options can be viewed or downloaded from www.abbinfozone.com
The 10DS3111E/A flanged sensors and 50SM1000 trans-mitters are AC magnetic flowmeters. These systems are recommended noisy slurries, applications involving pul-sating flow, and high speed of response applications.
Sizes 1 to 12 in. (10DS3111E); 14 in. to 24 in. (10DS3111A)
Transmitter 50SM1000
Pressure up to 740 psi @ 100F (see full specifications for more information) ANSI Class 150 (all sizes) and Class 300 (1 to 12 in.) flanges
Process Up to 356 F (max limit varies with Temperature liner selection)
Liner Hard or soft rubber (2 to 24 in.); Polyurethane (2 to 24 in.); Neoprene (2 to 24 in.); PTFE (1 to 24 in.); Tefzel (1 to 12 in.); Linatex (2 to 24 in.)
Electrodes Flush, bullet nose or slurry type in 316 stainless steel; Hastelloy C; Titanium; Tantalum; Platinum- Iridium; Zirconium
Sensor Epoxy painted cast Aluminum Housing
Sensor NEMA 4X (IP 65) General Purpose. Classification Option for FM Approved for Class I, Division 2, Groups A to D (See full Specifications for more information)
Transmitter NEMA 4X (IP 65) General Purpose Classification
System 1.0% (1.5 to 33.3 feet per second) Accuracy
Conductivity Greater than 20 µS/cm
Excitation AC
Communications HART, RS-485, or RS-232 options
Mounting Field mounted
Transmitter 115/230 V ac Power
Abridged Specifications:
10DS3111E/A Sensor with 50SM1000 Transmitter
Features/ Accidental sensor submergence (IP 67) Options Analog output Scaled frequency output Alarms Contact outputs Remote totalizer reset Empty pipe detection Bi-directional flow measurement Full Diagnostics Loop test mode Illuminated 2-line LCD display
![Page 2: Abridged Specifications: 10DS3111E/A Sensor with 50SM1000](https://reader031.vdocuments.us/reader031/viewer/2022021009/6203a9ccda24ad121e4c04f9/html5/thumbnails/2.jpg)
10DS3111
10DS3111 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Design Level (For Use w/Remote 50SM1000 Converter) Sizes 1" to 12" ............................................................ E Sizes 14" to 24".......... ................................................A
Meter Lay Length t Short Form (W-Mag), Standard (1/2" - 12" only) ........D Liner Hard Rubber ....................................................................... A Soft, Natural Rubber .......................................................... B Polyurethane ...................................................................... D PTFE Teflon ....................................................................... E Neoprene ............................................................................ L Tefzel .................................................................................. N Linatex (Consult Warminster for Price adder sizes ≥ 14")......... P
Size Y 25mm (1") ...........................................................................09 Y 40mm (1-1/2") .....................................................................11 50mm (2") ...........................................................................12 80mm (3) .............................................................................14 100mm (4") ...........................................................................15 150mm (6") ...........................................................................17 200mm (8") ...........................................................................18 250mm (10") .........................................................................19 300mm (12”) .........................................................................20
Poly or Neo. 350mm (14") ..........................................................................21 400mm (16") ..........................................................................22 450mm (18") ..........................................................................35 500mm (20") ..........................................................................23 600mm (24") ..........................................................................24
t Consult full specification for other optionsY Teflon or Tefzel Liner only.Æ Customer electrical connection box has PG 13.5 cable seal connections.v Customer electrical connection box has 1/2" NPT conduit seal connections.U 12-inch size only with Polyurethane or Neoprene liner; F-F is 18-inches (457 mm).
![Page 3: Abridged Specifications: 10DS3111E/A Sensor with 50SM1000](https://reader031.vdocuments.us/reader031/viewer/2022021009/6203a9ccda24ad121e4c04f9/html5/thumbnails/3.jpg)
10DS3111
10DS3111 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Flange Standard/Pressure Rating l ANSI Class 150.....................................................P l ANSI Class 300
Flange Material Carbon Steel, Standard ......................................... 1 304 Stainless Steel (150 Class only)
nProtector Plate None Required 316 Stl.Stl ..................................................................... B Hastelloy C ..................................................................... E
Electrode Design Flush, Standard ................................................................... 2 (Bullet Nose................................................................................ 3 vSlurry Service (14"-24" only) .................................................... 7 Electrode Material 316 Stainless Steel............................................................................B Hastelloy B ........................................................................................C Hastelloy C ........................................................................................D Titanium.............................................................................................E t Tantalum............................................................................................F t Platinum/Iridium (14" ≥ Consult Factory) .........................................H Zirconium...........................................................................................L
l Customer electrical connection box has 1/2 in. NPT conduit seal connectionsn For Teflon lined meters only. Serves as grounding ring.t Teflon or Tefzel Liner only.( 2" and larger sizes only. Electrode material must be Stainless Steel.v Liner must be Polyurethane, Linatex, or Neoprene and electrode material must be stainless steel.
![Page 4: Abridged Specifications: 10DS3111E/A Sensor with 50SM1000](https://reader031.vdocuments.us/reader031/viewer/2022021009/6203a9ccda24ad121e4c04f9/html5/thumbnails/4.jpg)
10DS3111
10DS3111 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Price
Certification General Purpose ................................................................. A FM Approved Cl I, Div. 2, Gps. A,B,C&D Standard ............ K Explosion Proof, FM Cl I, Div. 1, Gps B,C & D (1"-12" only)... L
Enclosure Classification IEC 529 IP 65, NEMA 4X ........................................................... 1 pIEC 529 IP 67, Accidental Submergence in water to 33 ft for 48 hrs ....................................................................... 2 U IEC 529 IP 68, Continuous Submergence in water to 33 ft ..... 5 UIEC 529 IP 67, Accidential Submergence to 33 ft. for 48 hrs and Potted Terminal Box (Level 9 Protection) .............................. 9
Process Temperature Range (For Liner Selection) Teflon PTFE or Tefzel, up to 266°F (130°C).....................................1 Teflon PTFE up to 356°F (180°C) (1"-12" only) ................................2 Hard Rubber, Linatex up to 175°F (80°C)........................................3 Polyurethane/Neoprene up to 190°F (88°C).....................................4 Teflon PTFE ≤ 302ºF (150ºC).............................................................5
Line/Excitation Frequency 50 Hz.........................................................................................................1 60 Hz, Standard ....................................................................................3
Customer Information Language English w/Riveted SST Tag ............................................................................. 2 zEnglish w/Self Adhesive Tag ....................................................................... 8
Remote Converter Type 50SM1000............................................................................................................... 1 Not specified .......................................................................................................... X
Permantly Installed Signal Cable tFor Enclosure Classification 5 & 9 Only Cable Length 50 Feet..................................................................................................05 Not Required ...............................................................................................................XX
p Standard 50 feet of cable furnished for each meter.U Cable is permanently attached and the length must be specified at time of order under "Permanently Installed Signal Cable" character. Level 5 is not available with Teflon liner material.t Consult Factory for Lengths over 50 feet. z Not available with continuous submergence enclosure (Class 5).
![Page 5: Abridged Specifications: 10DS3111E/A Sensor with 50SM1000](https://reader031.vdocuments.us/reader031/viewer/2022021009/6203a9ccda24ad121e4c04f9/html5/thumbnails/5.jpg)
50SM1000
50SM1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ Excitation Frequency 50 Hz ...................................... 1 60 Hz ........................................ 3
Certification .............................................A Primary Type 10DS3111 (1/2" - 12") ............................ 1 tv 10DS3111(14" - 24") .............................. 3
Design Level .......................................................... C
Software Level ............................................................. X Enclosure nNEMA 4X Field housing w/PG 13.5 Conn...................B NEMA 4X Field Housing w/1/2" NPT Conn. Standard D
Contact Outputs Octocoupler .......................................................................1 Relay Contact.....................................................................2
Pulse Outputs / Data Link Without Without ......................................0 Active Fwd & Rev. Without ......................................1 Without RS485........................................4 Without RS232........................................5
Contact Function Error Alarm ......................................................................................AA • Forward/Reverse Flow Signal.......................................................AB • Forward/Reverse Flow Signal & 2 Process Alarms ......................AC 2 Process Alarms ............................................................................BA
v Power supply must be 115 VACt Enclosure must be D
n Only available with primary type 1
• Includes error alarm. Forward/reverse signal is always via relay.
![Page 6: Abridged Specifications: 10DS3111E/A Sensor with 50SM1000](https://reader031.vdocuments.us/reader031/viewer/2022021009/6203a9ccda24ad121e4c04f9/html5/thumbnails/6.jpg)
50SM1000
50SM1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Additional Options None...................................................................................A External Totalizer Reset .....................................................B Zero Return ........................................................................C External Totalizer Reset & Zero Return ..............................D Empty Pipe Detector ..........................................................E Empty Pipe Detector & External Totalizer Reset................F ¨ ¨HART® Protocol .....................................................................G ¨ ¨HART® Protocol & Empty Pipe Detection..............................H ¨ ¨HART® Protocol & Empty Pipe Det. & Tot. Reset ..................J ¨ ¨HART® Protocol & Totalizer Reset .........................................T
Power Supply Æ115 Vac .....................................................................................C 230 Vac .....................................................................................A Customer Information Language English............................................................................................. 2
nSignal Cable Not Required.......................................................................................... 0 Required for 10DS3111E (1/2" - 12")..................................................... 1 Required for 10DS3111A (14" - 24")...................................................... 2
External Totalizer Reset Switch Not Required................................................................................................. 0 vRequired........................................................................................................ 1
Current Output 4 to 20 mA, Standard ........................................................................................1 0 to 20 mA............................................................................................................2
¨ Pulse output/data link must be 0 or 1.Æ Does not include power requirement for primary if Flowmeter Primary Type is 3.n 50 feet of cable is furnished as standard. Maximum cable length is 100 feet.