About Work Station Equipment
Manual Flap Valves Automatic Flap Valves
Fume Arms and Suspension Arrangements
An extraction system is sized for only those outlets which are to be used simultaneously. Th is is in order to maximize effi ciency and minimize the size of the central unit. It must be possible to open and close all outlets. Th is could be via manual shutter and fl ap valves or automatically on demand. Th e Flexpipe can be used for fume extraction, high fl exibility and small diameter allow it to be placed very close to the fume source.
Overhead suspension arrangements such as swing-arms and hose reels can increase the usefulness of the system, increase ergonomics and minimise potential trip hazards from hose left on the fl oor.When large volumes of material are to be introduced into the system, stainless fl oor funnels can be used from which the material is then extracted.
87
Work Station Equipment8
8
Cutter 108 has been developed for cutting plastic, paper and card-boardstrips and similar materials.Th e unit is connected to a f108 tubing system and will cut all material in the transport fl ow into 2–15 cm sized pieces. A rotor with three knives work against one stationary knife. Th e knives should be seviced at least twice a year at normal operation 8 hours a day. Depending on amount and type of material the knives should be sharpened and adjusted (500–5000 operation hours). Th e tubing system before and after the Cutter should consist of straight pipes. Because of safety reasons the inlet and outlet pipes should each be at least one metre long. At installation and service the safety considerations should allways be followed.Part No 7357
Exchange rotor Cutter 108 Part No 40677
Cutter 108
TECHNICAL DATA
Weight 19 kg
In-/outlet Ø108
Motor power 0.75 kW
50 Hz 60 HzRotation speed 2800 rpm 3400 rpm
Voltage 220–240/ 254–277/
360–415 440–480
88
Work Station Equipment 8
447201
8455
Flap valve 50/76 with microswitch.
dmax
/D A Control Finish Part No
38/50 mm X38 --- peened aluminum 3230
38/50 mm X38 micro-switch peened aluminum 8439
38/50 mm X38 --- white enamel 3231
38/50 mm X38 micro-switch white enamel 8453
Accessories
Part No 3219 Installation set with straight joint
Part No 3218 Installation set with 90o joint
Installation Examples
Wall outlets are available with two fi nishes; peened aluminum or white enamel.
Flap Valves
Flap Valves with micro-switch and attached lead
Part No 8455 Flap valve 50/76 (X50 connection)with micro-switch c/w 3 m lead and terminal box.
Part No 447201 Handle to upper valve.
Wall OutletsFor removable connection of the suction hose. Th e suction hose must be equipped with a connecting sleeve. Installed in the wall with an installation kit, these provide a fi nished, fl ush mounted outlet valve. Th e valve body with spring loaded fl ap is installed after the wall is fi nished. On systems with on demand start-stop, the wall outlet should be equipped with a micro-switch. Th is will give a start-stop signal for vacuum producer control.
For removable connection of the suction hose to the tubing system. Th e spring loaded fl ap is opened manually and the hose cuff is inserted into the valve body. On systems with on demand start-stop, the fl ap valve should be equipped with a micro-switch. Th is will give a start-stop signal for vacuum producer control.
dmax
/D A Microswitch Part No
38/50 mm X38 No 3232
38/50 mm X38 Yes 8454
50/50 mm X50 No 3070
50/50 mm X50 Yes 8433
50/76 mm X50 No 3006
50/76 mm X50 Yes 8272
76/76 mm X76 No 3237
89
Work Station Equipment8
8
G3G2½
Ø 76 Ø 76
U
D
B
C
Dimensions, Installation
dmax
/G A Cover Part No
50mm/G21/2 X50 stainless steel 3239
76mm/G3 X76 stainless steel 3238
TECHNICAL DATA Part No Max point load Max total load
3238 180 kg 360 kg
3239 180 kg 360 kg
Accessories
Clean Room Wall and Floor OutletTh e outlet can be used in ”clean room environments”. For removable connection of the suction hose. Th e spring loaded cover is fl ush with the fl oor and can be opened with a special tool, see below. Th e fl oor outlet’s connection to the tubing system is a standard NPT 2 ½”/ 3” thread. Connection is prepared then screwed in when the fl oor covering is installed.
Th e fl oor valves must be installed so that the tubing system carries the stress or so that the valve’s body ( A ) is installed on a level sub-surface. Floor outlets can be specially ordered with micro-switches.
Valve dim. Part No
B C D
G21/2 40378 7443+7428 40201
G3 40377 7442+7428 40201
Floor outlets are available with stainless steel or brass covers.
90
Work Station Equipment 8
Wall mounting
Hol
e in
wal
l ∅
85
and
∅ 1
04 m
m
Joint (optional)
Inductive sensor (optional)
Anchor plateWall mounting plate
Anchor plate
For wooden and raised fl oors
Anchor plate
Wall and Floor Outlet , Clean Room X38/50Th e wall and fl oor outlet is designed to meet the requirement for clean room application. Th e valve body is antistatic and made of pre-stressed polypropylene. Th e exposed surfaces of the valve are brushed stainless steel.
Th e outlet is made for both wall and fl oor mounting.
Cover wall mounting plate and spring replacement are possible without removing and replacing the valve body.
Low profi le for mounting even in thin wall partitions.
Outlet optionally equipped with inductive sensor for auto start - stop.
Select cleaning accessories Ø 32 or 38 mm.
Part No 322501Part No 84059 with sensor
For poured concrete fl oor
Accessories Description Part No Wall mounting plate high 42783
Rubberbend 90° Ø 50 2043
Straight joint 2044
Anchor plate 42264
Connector cleanroom 38 outlet 42292
O-ring 49,5 * 3 shore 50 nitril 40451
Hol
e
untingAnchor
Jo(o
(option
91
Work Station Equipment8
8
Solenoid Valve Part No. V
8088 24 V AC
8054 230 V
8026 24 V DC
Manual Shutter Valves
Electrical Shutter ValveWhen a shutter needs to be electrically controlled, use an automatic shutter valve, as above, in combination with a solenoid valve as shown here.
Electrically driven shutter valves can be built for special applications. Note that the speed of the gate will be much slower for an electrical shutter than for a standard shutter.
Manual shutter valves are used for stationary machine connection or in cases where a permanent hose connection is desired. By pulling the handle the valve opens. On systems with on demand start-stop, the shutter valve should be equipped with a micro-switch. Th is will give a start-stop signal for vacuum producer control.
Shutter Valve AutoTh e shutter valve has a stainless steel gate actuated by a pneumatic cylinder. For applications on work stations and in the tubing system. With intermittent start-stop, a pressure switch is installed using a ”T” fi tting in the compressed air supply. Th is provides an electrical start-stop signal to the vacuum producer. For valve position sensing, cylinder switches are optional available
D Part No
Ø 50 mm 805308
Ø 76 mm 804408
Ø 108 mm 808404
Ø 160 mm 825404
Ø 200 mm*/ 807500
Ø 250 mm*/ 807800
*/ Note! Shutter Valve φ200 and φ250 only for clean air
and to single step fans (10 kPa max).
D Control Part No
Ø 50 mm --- 805201
Ø 50 mm micro-switch 809101
Ø 76 mm --- 804300
Ø 76 mm micro-switch 809200
Ø 108 mm --- 808300
Ø 160 mm --- 8254
Ø 200 mm*/ --- 8017
Ø 250 mm*/ --- 8016
*/ Note! Shutter Valve Ø 200 and Ø 250 only for clean air.
V Part No
76 EL 230 804411
108 EL 230 808407
160 EL 230 825407
92
Work Station Equipment 8
8020
P
8 0 4 7
Pneumatic Tool Pneumatic Tool + man
Electric Tool Electric Tool + man
Stationary Machine Stationary Machine, 2
Accessories Shutter Valve Auto and El
Manual, intermittentstart/stop
Connection Schematic
Installed on pneumatic cylinders to supply electrical signals for start-stop control of vacuum producer. Gives signal when valve is opened.Part No 8047 Pressure Switch
Required for installation of the 8047 Pressure Switch.Part No 8152 T Fitting
For manual actuation of auto shutters. Part No 8040 Manual Switch
Actuates an auto shutter when installed in compressed air supply to a pneumatic tool. Controls on demand extraction. 8020 should be supported by compressed air according to PNEUROP 6611 CLASS 3. CA supply must be clean and dry, 90 PSI recommended.Part No 8020 Flow Valve
A separate solenoid is used for example, on stationary machines and in connection with a manual switch. Th e solenoid is connected pneumatically to the auto shutter. Generally installed in control panel of the subject machine.Part No 8026 Solenoid 24 V DCPart No 8054 Solenoid 230 V ACPart No 8088 Solenoid 24 V AC 50/60 Hz
Auto-start control is used for on demand extraction for electric tools ( max 8 amps on subject tool). Th e auto-start current sensor closes a relay to give solenoid actuation of an auto shutter.Part No 8196 Auto-start 230 vac
Accessories continued on the next page
93
Work Station Equipment8
8
4942
8001 8002
Welding Welding + man
Connection Schematic
AccessoriesPart No 4942 Silencer Ø 100 300/200
Used for automatic control of extraction in induction welding applications. Striking an arc will cause the current sensor to close a relay. In turn the relay causes solenoid actuation of an auto shutter. Th is control must be supplied with 24 V AC, 0,5 A.Part No 8168 Welding Auto-startwith current sensor
Supply transformer for 8168 Welding Auto-startPart No 8029 Transformer 230/24 V AC 4 A
Th e vacuum relief valve bleeds in air at the pre-set relief level and can be installed at the outermost point on a tubing system. Th e valve will introduce transport air into the system when the pressure in the system exceeds the setting of the vacuum relief valve.Part No 8001 Vacuum Relief Valve ø76Part No 8002 Vacuum Relief Valve ø108
Vacuum Relief Valve
Accessories Shutter Valve Auto and El
94
Work Station Equipment 8
Connection Schematic Extraction Arms
AutoMan
ø76
Dimensions, Extraction Arm
Fume Extraction Arm
Extraction arm for welding fume etc. Th is articulated arm is easily adjusted to the correct working position. Th e hood is equipped with a 24 V 50 W halogen work lamp and dual switches for lamp and Shutter Valve El control. Th e 76 mm Extraction arm should always be installed with 1 m of 76 mm hose between the arm and tubing system.ø76 Part No 590102
TECHNICAL DATA Qnom
Δpnom
Ø76 400 m3/h 3 kPa
In high pressure systems, the extraction arms may require a restrictive plate
to compensate pressure for suitable air fl ow.
95
Work Station Equipment8
8
5726
5725
7331/7332
7330/7308
kPa Δp
2,5
2,0
1,5
1,0
0,5
00 100 200 300 400 500
Q
m3/h
ø50
ø76
5725
5726
Swingarm for Flexpipe
Mounting alternatives
Dimensions
Pressure Loss Swingarm
Q
m3/h
kPa Δp
2,5
2,0
1,5
1,0
0,5
00 100 200 300 400 500
ø50
ø76
Pressure Loss Flexpipe
In high pressure systems, the fl expipe may require a restrictive plate to compensate pressure for suitable air fl ow.
Th e Flexpipe reach can be increased with swingarm installation. Th e swingarm length is easily adjusted by either cutting the horizontal tube or by replacing it with a longer tube from the standard tubing system, max. 3 m for Ø 50 and max. 4 m for Ø 76. Th e swingarm may be equipped with suction hose but should not be loaded with anymore than the weight of the hose itself.Ø 50 Part No 5725
Ø 76 Part No 5726
FlexpipeDustcontrol’s Flexpipe is a type of extraction arm for source extrac-tion of welding fume, chemical vapors, wood dust, etc. Th e fl expipe is a fl exible hose that can be placed in practically any ori entation desired.Diameter of the Flexpipe is small and it can be used very close to the source without disturbing the work. Extraction is very eff ective.
Part No. 7330 7308 7331 7332
Inner Diameter ø 50 ø 50 ø 76 ø 76
Tubing System
Connection joint ø 50 joint ø 50 joint ø 76 joint ø 76
Length 700 mm 1 m 700 m 1 m
Air Flow 80–200 m3/h 80–200 m3/h 200–450 m3/h 200–450 m3/h
96
Work Station Equipment 8
5740
Special
kPa Δp
3
2
1
00 100 200 300 400
Q
m3/h
864,53,52,5
Swingarms
Dimensions Mounting Alternatives
Swingarms are used to increase the working envelope without increasing hose lengths. Optionally, tools can be suspended from the swingarm.Part No 5720 2.5 mPart No 5721 3.5 mPart No 5722 4.5 mPart No 5723 6 mPart No 5724 8 m
AccessoriesTh e suspension track is installed on the inner link of the swingarm.Part No 5740 Linear Suspension Track
Pressure Loss Swingarm
Part No 5720 + 5740
Part No 5721 + 5740
Part No 5722 + 5740
Part No 5723 + 5740
Part No 5724 + 5740
97
Work Station Equipment8
8
Hose Reel Th e Dustcontrol hose reel for 38 and 32 mm hose can be used with all available 38 mm accessories. Th e hose reel mechanism is equipped with a latch mechanism allow-ing the user to take out as much hose as required and then retracting it onto the reel for storage. Vacuum through the reel is controlled by a combi nation of pneumatic switch and automatic shutter valve. Th e tubing system opens automatically when the hose is withdrawn from the reel. Th e hose reel is supplied with an articulating mounting bracket.Part No 7397 Hose Reel 32 mm, complete
Part No 7305 Hose Reel 38 mm, complete
TECHNICAL DATA 32 mm 38 mm
Hose Part No/length 2005/10 m 2038/7.5 m
Connection diameter Ø 50 Ø 50
Copressed air supply min 5 bar (75 psi) min 5 bar (75 psi)
For specifi c information about the hoses - Material properties Hoses (page 144).
98
Work Station Equipment 8
4149 7148
6098
7150
6005
6610
6616
Part No Description Connection (Ø) (in/mm)
4149 Suction nozzle 2”/50
6005 Universal nozzle 1.5”/38
6098 Tubular nozzle 1.5”/38
6610 Universal nozzle 1.5”/38
6616 Universal nozzle Ø 50 2”/50
7148 Funnel shaped nozzle Ø 50 2”/50
7150 Magnetic holder for 7148, 4149 2”/50
TECHNICAL DATA
Part No Qnom Δpnom
4149 150 cfm/250 m3/h 6.4inwg/1.6 kPa
6005 90 cfm/150 m3/h 6.4inwg/1.6 kPa
6098 90 cfm/150 m3/h 15.2 inwg/3.8 kPa
6010 90 cfm/150 m3/h 6.4inwg/1.6 kPa
6616 250 m3/h 6.4inwg/1.6 kPa
7148 150 cfm/250 m3/h 6.4inwg/1.6 kPa
9060 90 cfm/150 m3/h 10.8 inwg/2.7 kPa
Welding Accessories/Extraction Nozzles
99
Work Station Equipment8
8
About Control SystemsTh e control system is used for the starting and stopping of the vacuum producer, turbo pump or high pressure fan. Th ey also control fi lter cleaning and give condition indications. In the system control panels, additional functions can be built in by selecting options.Control systems must be installed by a certifi ed electrician. Th e control panels conform to electrical protection class IP 54 (IC529). Manufacturing standards conform to EN60204 (IEC204-1), VDE0113A2/381, DIN 57113A2. Main fuses and working disconnects are not included in the control panels..
System Control PanelsSelect confi guration of system control panel by optional additional digits.
Example
System Control Panel 86 ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤Standard (IP54, painted cabinet) 861 ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤1 pump 8611 ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤18.5 kW 86119 ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤400 V, 50 Hz 861196 ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤Solenoid valves 24 V AC 861196 1 ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤Filter cleaning S 32000: After stop and man 861196 15 ⎣⎤ ⎣⎤ ⎣⎤ ⎣⎤Airlock control 160 861196 151 ⎣⎤ ⎣⎤ ⎣⎤Clean out/Flush valves 2 pcs. 861196 1512 ⎣⎤ ⎣⎤Electronic clock/External signal: No 861196 15120 ⎣⎤Lighting + power point 230V 6A in cabinet 861196 151202
System control panels are always delivered with
• Main switch• All condition indications and manoeuvres on display at front• PLC-control• Motor circuit breaker• Function for start and stop of pump/fan with soft start • Pulse control for fi lter cleaning• Start from external signal, prepared for intermittent run (10 min
stop delay)• Manual start on display• Timers for fi lter cleaning and intermittent run can be altered on
display• Connection of thermal protection (pumps of 11 kW and more)• Condition indications and alarms on display• Start on demand for lag pumps/fans (panels for 2 and 3 vacuum
producers)• Signal for shutter valve shutting at start (fans)
All condition indications and manoeuvres on display at front of system control cabinet.
Dimensions (base confi guration)
Measure Height Width Depth
1 pump/fan 2.5–11 kW 600 380 210
1 pump/fan 15–22 kW 700 500 250
1 pump/fan 30–37 kW 800 600 250
2 pump/fan 2.5–11 kW 800 600 250
2 pump/fan 15–22 kW 760 760 300
2 pump/fan 30–37 kW 1000 800 300
3 pump/fan 2.5–11 kW 1000 800 300
3 pump/fan 15–22 kW 1200 800 300
3 pump/fan 30–37 kW 1200 1000 300
100
Control Systems 9
Control Systems for USA/Canada
System Control Panels
Base System Control panels are confi gured with;
• Lockable Main disconnect• Fusing on main feed and control fusing• LED Indicators• Pilot Devices for Operation• Direct magnetic motor starter• Motor overload protection • Pulse control for fi lter cleaning• PLC Control• Connection for Turbo pump Th ermal KLIXON• NEMA 12 Enclosure
Dustcontrol maintains a policy of active development for controls and control systems and recognizes that there are more ”special control” confi gurations available than basic. Th e basic panel confi guration above is the minimum required for the basic operation of an extraction system. When your requirements, or the requirements of the system, become more complex, we will be there. We can customize a control solution for you, from basic to complex multiple system architectures and everything in-between.
Some examples of options available:
• Reduced Voltage StartersSometimes referred to as a soft-start. Th ese devices are pre-progammed to give a gradual application of voltage as a motor starts. Th ey usually slow the motor start to 5 or 10 seconds and reduce the current in-rush to the motor. Th is results in less stress on electrical and mechanical parts and contributes to enhanced reliability of motors, starter components, overloads and the vacuum producer. Let us show you the benefi ts.
• Variable Frequency DrivesCommonly referred to as VFD’s or drives. Th ese devices allow us to program and control the behavior of the motor. Th e available parameters in a VFD let us, not only soft start your vacuum producer, but provide a whole range of operational parameters to make your system smarter. VFD’s can be demand controlled by a PLC to provide vacuum production on demand. Ramp up when the system usage requires it and idle back to save you energy when system utilization is low. As well as the enhanced control, VFD’s provide an un-paralleled degree of feedback for trouble shooting and power quality diagnostics
Dustcontrol USA supplied electrical control panels are UL listed and bear the serialized UL mark listing.
Dustcontrol Canada supplied electrical control pa-nels are CSA approved and bear the CSA mark.
• Touch ScreensTouch Screens can be added to a system control to give the operator more input/output capability. A standard black and white screen can be used to replace indicator lamps and pilot devices and is easily justifi ed on a cost basis. Larger and higher resolution color screens let us program more enhanced feedback for the user and allow the user access to parameters that would not be available from PB’s and indicator lamps. Access to diff erent parameters can be password protected, supervisors can adjust fi lter cleaning directly, for example.
• SensorsDustcontrol can use many diff erent types of sensors in the extraction system to inform the control and operators of diff ering system conditions.
• Proximity Sensors - monitor levels in silos.• Ultrasonic sensors - monitor fi lling levels in containers.• Temperature sensors - monitor motor, pump and exhaust temp.• Flow sensors - control velocity and fl ow rate.• CT Coil - montior current demand on a vacuum producer.• Inductive Position Sensors - feedback on an object’s position
• Network Ready Architecture: we can program the PLC to be network ready and have access to the World Wide Web. Web access ads a whole range of possibilities; remote monitoring, remote diagnostics and software upgrades over the web.
101
Control Systems9
9
System Control Panel
Starter
Starter for manual or microswitch start
Part No 8117, 2.5 kW, 400 V
Part No 8119, 2.5 kW, 230 V
Part No 8132 Starter for microswitch or manual start and function for automatic fi lter cleaning.
102
Control Systems 9
DC Green System
Lower power consumption•
No micro switches•
Higher peak performance•
Optimum suction performance •
at all times
Increased lifetime of the va-•
cuum system
Why not reduce your carbon footprint and at the same time cut your costs?
DC 11-Module with DC Greensystem
Dustcontrol´s patented DC Green System is a system for the control of vacuum producers that helps to save energy. Th e DC Green System together with our vacuum producers (radial blowers and turbo pumps), can potentially off er you an energy saving with existing or new Dustcontrol vacuum producers of between 40 and 90 percent.
Depending on the number of open outlets, the RPM of the vacuum producer is optimized by the DC Green System, generating just as much vacuum as needed. By using a sophisticated on-demand control with a frequency converter, the maximum performance is also increased compared to a normal system. When no outlets are open the vacuum producer automatically switches to a saving mode. Th is eliminates the need for electrical microswitches at each work station.
Depending on individual cases and the current market price of electricity; payback time for the purchase of the DC Green System is generally between 1-5 years. In summary, lower energy consumption contributes to economic savings, less environmental impact and an increased life span of the equipment.
Your Dustcontrol contact can calculate the estimated saving in your case.
103
Control Systems9
9
Dustcontrol DC Green System™
Traditional Vacuum System
Part of total working hours
Number of users
Part of total working hours
Number of users
104
Control Systems 9
DC Green System for 1 turbopump
Part No 87 1 1 4 E 1 3 0 0 0 0D
C G
reen
Sys
tem
Cat
egor
y
Vac
uum
Pro
duce
r
Pow
er
Ele
ctric
al S
uppl
y
Vol
tage
Sol
enoi
d V
alve
s
Filte
r Cle
anin
gD
isch
arge
Shu
tter v
alve
s
El.
Clo
ck/E
xter
nal s
igna
Ext
ras
CATEGORY FILTER CLEANING1 Standard 1 S11/21000: After stop, man and during run 3
S32000: After stop, man and during run 6VACUUM PRODUCER S34000: After stop, man and during run 9
1 pump 1DISCHARGE
No 0POWER Airlock 160 1
11 kW 6 Airlock >160 215 kW 8 Discharge valve 318,5 kW P-pump 9 Auger Compactor 422 kW P-pump A30 kW P-pump B SHUTTER VALVES18,5 kW S-pump D No 022 kW S-pump E Clean out valve 1 pcs. 130 kW S-pump F Clean out valves 2 pcs. 2
Clean out valves 3 pcs. 3ELECTRICAL SUPPLY Clean out valves 4 pcs. 4
380-480V, 50/60 Hz E Shutting off valvel (filter unit) 5
VOLTAGE SOLENOID VALVES ELECTRONIC CLOCK/EXTERNAL SIGNAL24 VAC (Standard) 1 No 024 VDC 2 Electronic clock weekly, external 1110 VAC 3 Electronic clock weekly, internal PLC (RTS) 2230 VAC 4 External alarm signal 3
External operation signal - pump/fun runningt 4External switch - start requirement 5
EXTRASNo 0Power point 230V 6A in cabinet 1Lighting + power point 230V 6A in cabinet 22 pressure sensors 33 pressure sensors 44 pressure sensors 5
Selections, DC Green System
105
Control Systems9
9