abb’s comprehensive range of breakers and...

72
The range of ABB breakers and switches ranks amongst the most extensive on the market with a full range of innovative solutions for various applications, helping to optimise resources, reduce energy costs, boost productivity. - Moulded case circuit breakers - Air circuit breakers - HRC fuse & Fuse base - Switch disconnector fuse ABB Low voltage Breakers & Switches | ABB’s comprehensive range of breakers and switches 7 - Switch disconnectors - Changeover switches - Manual & Motorized - Auto transfer switches - Cam switches - Cable distribution cabinet - Kabeldon - Fuse gear - Easyline and Inline (Fuse switch disconnector) - Switche disconnector for DC application - Photovoltaic MCCBs ABB’s comprehensive range of breakers and switches 1

Upload: truongnhan

Post on 06-Feb-2018

289 views

Category:

Documents


1 download

TRANSCRIPT

The range of ABB breakers and switches ranks amongst the

most extensive on the market with a full range of innovative

solutions for various applications, helping to optimise

resources, reduce energy costs, boost productivity.

- Moulded case circuit breakers

- Air circuit breakers

- HRC fuse & Fuse base

- Switch disconnector fuse

ABB Low voltage Breakers & Switches | ABB’s comprehensive range of breakers and switches 7

- Switch disconnectors

- Changeover switches - Manual & Motorized

- Auto transfer switches

- Cam switches

- Cable distribution cabinet - Kabeldon

- Fuse gear - Easyline and Inline (Fuse switch disconnector)

- Switche disconnector for DC application

- Photovoltaic MCCBs

ABB’s comprehensive range of breakers and switches

1

ArTu. Born certified.

Fully checked and certified (IEC 60439-1 and IEC 61439-1

and 2 Standard) by an external independent organisation

(AcaeLovag), the ArTu switchgear is a synonym of safety and

quality. The certification is the fruit of severe tests carried

out on the whole configuration, consisting of metalwork

structures, circuit-breakers and busbar system.

The ArTu K series switchgear is ideal for primary distribution

switchgear (PowerCenter type) upto 6300A with air and

moulded-case circuit-breakers and any internal segregations

up to Form 4, and for floor-mounted secondary distribution

switchgear with moulded-case and modular circuit-breakers.

The switchgear have been tested for Internal Arc and

Seismic.

8 ArTu. Born certified. | ABB Low voltage Breakers & Switches

1

Emax - Low voltage air circuit breakers

Faults: no problem Extremely simple ModularityCompletely new protection

releases

– CT (Rogowski coil) range of 400 - 6300A (E1,E2,E3,E4 and

E6) with breaking capacity range of 42-150KA

– Configured breakers are now available in E1, E2 and E3

frames

– SACE Emax circuit-breakers and their accessories conform

to the international IEC 60947, EN 60947 CEI EN 60947

and IEC 61000 standards and comply with following EC

directives “Low Voltage Directive” (LVD)

no 73/23 EEC

– “Electromagnetic Compatibility Directive” (EMC) nr. 89/336

EEC

– Complete range of common accessories

– Double insulation

– Same height and depth for the whole range

– Protection releases provide complete set of standard

protection function, advanced protection functions,

Measurement functions

– Optional modules (measurements, signalling,

communication, wireless com) to upgrade the protection

releases

– Neutral protection from OFF to 200%

– Interchangeability of releases

– Low voltage switch disconnectors and automatic circuit

breakers for direct current applications is available up to

5000A, 1000VDC

Note : Please contact the nearest sales office for the prices

ABB Low voltage Breakers & Switches | Emax - Low voltage air circuit breakers 9

1

Emax - Low voltage air circuit breakers

Note: 1. Withdrawable fixed parts ( WFP ) and withdrawable moving parts ( WMP) are to be ordered together for a

draw out complete breaker

2. To convert the breaker from manual operated (MDO or MF) to electrical operated (EDO or EF), please order MDO/EDO conversion kit which

comprises of closing coil, opening coil and motor operator. Suitable operating voltage for the conversion kit has to be mentioned.

3. For other current rating and breaking capacity ACB requirement, please contact our nearest sales office

4. For frame E4 configure breaker will be available from April 2015, please contact our nearest sales office

* All the configured breaker will have accessories fitted from the factory

Configured breakers*Ordering code for Emax - 3 pole

PR121 LI PR121 LSIG PR122 LSIG

E1 - Withdrawable fixed oart - WFP - HR-HR 1SDA059666R1

E1 - 50KA -Withdrawable

moving part - WMP

800 A Manual 1SDA055712R1 1SDA055714R1 1SDA055717R1

1000 A Manual 1SDA059214R1 1SDA059222R1 1SDA059234R1

1250 A Manual 1SDA055744R1 1SDA055746R1 1SDA055749R1

1600 A Manual 1SDA055776R1 1SDA055778R1 1SDA055781R1

Configured breakers*Ordering code for Emax - 4 pole

PR121 LI PR121 LSIG PR122 LSIG

E1 - Withdrawable Fixed Part - WFP - HR-HR 1SDA059762R1

E1 - 50KA -Withdrawable

moving part - WMP

800 A Manual 1SDA055720R1 1SDA055722R1 1SDA055725R1

1000 A Manual 1SDA059216R1 1SDA059224R1 1SDA059236R1

1250 A Manual 1SDA055752R1 1SDA055754R1 1SDA055757R1

1600 A Manual 1SDA055784R1 1SDA055786R1 1SDA055789R1

Configured breakers*Ordering code for Emax - 3 Pole

PR121 LI PR121 LSIG PR122 LSIG

E2 - Withdrawable fixed part - WFP-HR-HR 1SDA059667R1

E2 - 65KA -Withdrawable

moving part - WMP2000 A Manual 1SDA055936R1 1SDA055938R1 1SDA055941R1

Configured breakers*Ordering code for Emax - 4 Pole

PR121 LI PR121 LSIG PR122 LSIG

E2S - Withdrawable fixed part - WFP-HR-HR 1SDA059763R1

E2S - 65KA -Withdrawable

moving part - WMP2000 A Manual 1SDA055944R1 1SDA055946R1 1SDA055949R1

Configured breakers*Ordering code for Emax - 3 Pole

PR121 LI PR121 LSIG PR122 LSIG

E3 - Withdrawable fixed part - WFP - HR-HR 1SDA059669R1

E3 - 65KA -Withdrawable

moving part - WMP

2500 A Manual 1SDA056128R1 1SDA056130R1 1SDA056133R1

3200 A Manual 1SDA056160R1 1SDA056162R1 1SDA056165R1

Configured Breakers*Ordering code for Emax - 4 Pole

PR121 LI PR121 LSIG PR122 LSIG

E3 - Withdrawable fixed part - WFP - HR-HR 1SDA059765R1

E3 - 65KA -Withdrawable

moving part - WMP

2500 A Manual 1SDA056136R1 1SDA056138R1 1SDA056141R1

3200 A Manual 1SDA056168R1 1SDA056170R1 1SDA056173R1

10 Emax - Low voltage air circuit breakers | ABB Low voltage Breakers & Switches

1

Tmax guarantee for reliable performance with smaller foot

prints, easy installation and increased safety with double

insulation.

The Tmax series are particularly suitable for secondary

distribution in AC/DC and provides solution for every

application

Scope:

Tmax series is offered in seven frame sizes with application in

industrial, commercial and residential purposes. Available for

both AC and DC networks of low voltage application. Tmax is

suitable applications in

- Power distribution

- Motor protection application

- Generator application

Device range:

To meet different requirements, Tmax series is available in the

following ranges:

- Automatic circuit breakers for AC & DC

- Automatic circuit breakers for advanced zone selectivity

- Automatic circuit breakers for motor protection

Tmax moulded case circuit breakers

- Switch disconnectors

- Automatic circuit breakers for applications up to 1,150 V

for AC and 1,000 V for DC

Available versions are 3P & 4P in fixed (T1 to T7), plug-in(T2

to T5) and withdrawable(T4 to T7).

Tmax circuit breakers are offered with standardized

accessories providing flexibility to customers.

Tmax range is available in both thermo magnetic and

electronic protection releases

Specific features:

Tmax is one of best circuit breaker in the industry when

performance/size ratio is compared. The specially designed

contact system and arc chutes guarantee let- through energy

is limited in safe guarding downstream connected equipment.

Tmax circuit breakers offered in 7 frame sizes provides

versatile functionality and flexibility to customers in selecting

optimal rating based on performance requirement.

ABB Low voltage Breakers & Switches | Tmax moulded case circuit breakers 11

1

Trip Units

Thermal magnetic trip units

- MA - Magnetic only trip unit with adjustable magnetic thresholds for motor protection

- TMF - Fixed thermal and fixed magnetic for power distribution

- TMD - Adjustable thermal ( 70-100%of In) and fixed magnetic (10 x In) for power distribution

- TMA - Adjustable thermal ( 70-100% of In) and adjustable magnetic ( 5-10 of In) for power distribution

- TMG - Adjustable thermal ( 70-100% of In) and low fixed magnetic ( 3 x In) for generator protection

Microprocessor based electronic trip units

PR 223 EF Early fault detection and prevention from T4 - T7. Details on request

Tmax power distribution circuit breakers

Type Iu (40° C)[A] Ue [V] Category Release Icu (380 - 415 V AC) [kA]

AC DC 16 25 36 50 70 85 100 120 150 200

T1 160 690 500 A TMD B C N

T2 160 690 500 A

MA (100 A)

TMD

MF (12,5 A)

PR221DS

N S H L

T3 250 690 500 A

MA

TMD

TMG

N S

T4250

320

690

1150

750

1000A

MA (200 A)

TMD (50 A)

TMA (250 A)

PR221DS

PR222DS

Ekip M

PR223DS/EF

N S H L V

T5400

630

690

1150

750

1000

B (400 A)

A (630 A)

TMA (500 A)

TMG (500 A)

PR221DS

PR222DS

Ekip M

PR223DS/EF

N S H L V

T6

630

800

1000

690

1150

750

1000

B (630A - 800 A)

A (1000 A)

TMA (800 A)

PR221DS

PR222DS

Ekip M

PR223DS/EF

N S H L V

T7

800

1000

1250

1600

690 B

PR231/P

PR232/P

PR331/P

PR332/P

S H L V

PR221

L = 0.40 - 1 of In

PR222

L = 0.4 - 1 of In

PR231

L = 0.4 - 1 of In

PR331

L = 0.4 - 1 of In

S = 1 - 10 of In S = 0.6 - 10 of In S = 1 - 10 of In S = 0.6 - 10 of In

I = 1 - 10 of In I = 1.5 - 12 of In I = 1 - 12 of In I = 1.5 - 15 of In

G = 0.2 - 1 of In G = 0.2 - 1 of In

12 Tmax power distribution circuit breakers | ABB Low voltage Breakers & Switches

1

Switches

ABB has a wide portfolio of low voltage switches. They

are suitable for diverse applications, in motor control

centers, in switch boards and as main switches in various

equipments and machines. From single to 8 poles and

combination switches for change-over, automatic transfer,

bypass, reversing etc.

Switch-disconnectors 16 – 4000 A

The switch disconnector is largely used as the main switch in

low voltage switchgears for distribution of power, starting and

stopping motors and isolating loads during maintenance.

The range from 16 to 125 Amps are either base plate or door

mounted by snap-on or screw fitting front operated 3, 4, 6 and

8-pole are available as standard.

From 160 to 4000 Amps the switch disconnectors, also called

load break switches, are designed as pole modules and they

are available as 1, 2, 3 and 4-pole versions, front or side

operated.

Switch Disconnector fuses 16 – 1250A

The switch disconnector fuese is used as the main switch in

low voltage switchgears in industry for distributing power and

protecting motors, cables and other devices against short

circuits and over loads.

The switch disconnector fuses are available for all types of

fuse links, DIN, BS, NFC, UL, CSA.

The range includes single pole to four pole versions, front- or

side-operated. The pole module design enables location of

the operating mechanism in any position together with the

direction of the terminals giving flexibility to installation in

different types of cubicle designs.

Change-over and transfer switches 16 – 3200 A

ABB’s change-over and transfer switches are designed to

transfer loads from one power source to another in a wide

variety of applications.

The range includes switches from 16 to 3200 Amperes, which

can be operated manually, remotely by using a motor or

automatically.

ABB’s change-over and transfer switches are tested according

to IEC 60947-6-1 and IEC 60947-3 standards. The switches

have ratings in AC31 and AC33 utilization categories, up to

415 V. In motorized switches, the motor operators have a wide

voltage operation range.

Enclosed switches.16 – 1600 A

The ABB enclosed switches are suitable for power distribution

in factories and buildings, as local motor isolators and as main

switches. Each incoming supply shall be provided with a hand

operated main switch-disconnector according to the Machine

Directive EN 60204 and isolate reliably the electrical equipment

from the supply. ABB enclosed switches are designed and

tested to meet these requirements and complies with IEC 60

947-3.

The enclosed switches are easy to install and safe to use in

industrial, public and residential environments. The indication of

the handle is always reliable and lockable in the OFF-position

with a standard padlock. ABB’s long experience in switch

disconnects guarantees a long and safe use

Cam switches 10 – 315 A

ABB’s new OC, OM, ON and OL rotary cam switches offer a

complete range of cam switches for control, instrumentation

and motor starting applications, maximizing the benefits and

optimizing your use of assets. The standard cam switches

provide you with a variety of functionalities for the most

common mounting types and applications with minimum

footprint area.

ABB Low voltage Breakers & Switches | Switches 41

1

The range of ABB control products ranks amongst the

most extensive on the market with a full range of innovative

solutions for Control & Protection, Motor Starting, Intelligent

motor management, measurement and monitoring and

connection applications.

The business unit is comprised of 3 main product families :

– Control & Protection

– Electronic Relays

– Connection Devices

Our products

Our products are already among the most extensive in the

market and we are constantly adding new products in order

to meet ever changing customer needs.

Quality and reliability are built into every device to ensure

total performance satisfaction, even in the most demanding

applications.

We offer a very modern and competitive range of contactors,

softstarters, starters, manual motorstarters, a wide range

of electronic relays and overload relays, together with an

extended program of pilot devices.

Our offering

– Contactors

– Manual motor starters

– Thermal overload relays

– Electronic overload relays

– Soft starters

– Intelligent Motor Management Systems

– Universal Motor Controllers

– Communication Fieldbus Plugs

– Electronic Products and Relays

– Timers

– Measuring and monitoring relays

– Power Supplies

– Analog Signal converters

– Interface Relays & Optocouplers

– Jokab Safety Systems

– Pilot devices

– Arc Guard Systems

– Current & Voltage Sensors

– Terminal blocks

ABB's comprehensive range of LV control products

2

58 ABB's comprehensive range of LV control products | ABB Low voltage Control Products

Accessories for AF contactors

AF the premium range

NEW

VEM4 mechanical and electrical interlock set including:

– VM4 mechanical interlock unit with 2 fixing clips

– VE4 electrical interlock block with A2-A2 connection

A2

VE4

Interlock

AF contactor

VM

CAL4-11

2-pole auxiliary

contact block

AF contactor

(without top mounted

coil terminal block)

TF

EF

Overload relay

TF42

EF

Overload relay

Fixing clips

A2

AF contactor

AF09 ... AF96

AF09 ... AF65

AF09 ... AF38

BX4

Protective cover

BX4-CA

Protective cover

BX4-CA

Protective cover

BX4-CA

Protective cover

CAL4-11

2-pole auxiliary

contact block

CA4, CC4

1-pole auxiliary

contact block

CA4

4-pole auxiliary

contact block

CAT4-11

2-pole auxiliary contact

and A1/A2 coil terminal block

CA4, CC4

1-pole auxiliary

contact block

CA4, CC4

1-pole auxiliary

contact block

TEF4

Electronic timer

The AF contactor is compact

The AF contactor is compact in size and has had its width re-

duced by up to 30% thanks to an 80% reduction of the coil‘s

energy consumption.

2

72 Accessories for AF contactors | ABB Low voltage Control Products

The AF contactor is flexible

AF09...AF370 is perfect for motor starting applications and for

solutions where space is limited. Interlocked reversing pairs

require no spacing between contactors meaning you can fit

more functionality into cabinets or other small enclosures.

Softstarters ABB softstarters - The complete range

ABB offers four different ranges of softstarters to cover

every customer need for solutions for motor sizes up to

1800 A. This page decribes the main characteristics of the

different softstarter ranges

PSR - The compact range

The PSR softstarter is the most compact of all the softstarter

ranges, thereby making it possible to design compact starting

equipments. The system concept with Manual Motor Starters

and the PSR provides a far more compact starting solution

than for instance a star delta starter.

Built-in by-pass reduces the energy loss and makes the

connection easier and with only three potentiometers, the

set-up couldn't be any easier. Still, the optimized ramping

characteristics will ensure a very smooth start and stop for all

applications.

PSE - The efficient range

The PSE soitstarter is the world's first compact softstarter

with both built-in electronic overload for motor protection and

torque control for an excellent control of pumps. The compact

design with the most important functionality integrated

provides a very efficient starting solution.

The illuminated language neutral display and the four button

keypad make it easy to take advantage of all the advanced

functionality in the softstarter. The display will also provide all

the necessary information both during

PST(B) - The advanced range

The PST(B) softstarter is the most advanced sottstarter in

the range with almost all imaginable functionality included. All

the advanced protections for the motor, the softstarter and

the load ensure a trouble free operation. Pre-warnings even

aliow problems to be detected before the motor needs to be

stopped

The torque control function has been developed and tested

together with well known pump manufacturers to ensure

the absolutely best possible stop of pumps without water

hammering and pressure surges. and there by avoiding

unnecessary downtime.

With the full text LCD display in your own language, pre-prow

grammed

application settings and event logging, it couldn't be easier to

set-up and operate.

By using the ABB FieldBusPlug, you can decide at any time

which bus protocol to use. The fieldbus system will allow you

to set-up, control and monitor the sottstarter.

PSR18 - 600 -70}

Control supply voltage: 70 = 100 - 250 V AC

81 = 24 V DC

Operational voltage: 600 V

Current rating: 18 A

Softstarter range

PSR18 - 600 -70

O O

O

O O

O

O

-

- -

- -

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

- -

-

-

-

-

PSR PSS PSE PST(B) Standard O Opional - Not available

1) Built-in by-pass

Inside delta connection

Coated PCBs

Display and keypad

Torque control

Settable current limit function

Elecironic motor ovedoad protection

PTC input for motor protection

Phase imbalance protection

Phase reversal protection

Locked rotor protection

Thyristor overtemperature protection

Underload protection

Programmable warning functions

Analog output

FieldBus communication

Event log

External keypad

PSR PSS PSE PST(B)

The PSTX combines many years of research and product

development with extensive knowledge of application

specific requirements and needs.

It is our latest advancement in motor control and

protection and adds new functionality and increased

reliability.

– Three-phase controlled

– Operational voltage: 208 – 690 VAC

– Wide rated control supply voltage: 100 – 250 V, 50/60 Hz

– PSTX rated operational current: 30 to 370 A (inside-delta:

640 A)

– Both in-line and inside-delta connection

– Coated circuit boards protecting from dust, moist and

corrosive atmosphere

– Detachable keypad rated IP66 (Type 1, 4X,12)

– Graphical display with 14 languages for easy setup and

operation

– Built-in bypass for energy saving and easy installation

– Built-in Modbus RTU for monitoring and control

– Support for all major communication protocols

– Analog output for measurement of current, voltage, power

factor etc.

NEW

2

86 Softstarters | ABB Low voltage Control Products

2 Measuring and monitoring relays, CM range

State of the Art monitors for single and three-phase systems.

Monitoring of: voltage, current, frequency, power factor (motor

load), thermistors, temperature, liquid level, insulation resistance,

and grid feeding. ABB has one of the world’s widest product

ranges of measuring and monitoring relays. The CM range is a key

product line of the EPR range.

Electronic products and relays

The product range

3 Power supplies, CP range

Modern power supply units are a vital component in most areas of

energy management and automation technology.

As your global partner in this area, ABB pays close attention to

corresponding requirements. Innovation is the key to the

substantial enlargement of our power supply product range. ABB

offers four different product lines for single and three-phase sup-

plies, output voltages 5/12/24, and 48 VDC in plastic and metal

enclosure, as well as various accessories.

4 Signal converters, CC range and ILPH

The ABB serial data converters allow communication to be

established between units with different communication

standards. In order to assure process continuity, existing systems

must be updated consistently or connected to new devices. Serial

data enables communication to be established if the communi-

cation standard of the existing system and the connected device

vary. As well as converting signals, analog signal converters and

serial data converters can amplify, filter or separate signals.

5 Interface relays and optocouplers, CR range and R500 / 600

Interface relays and optocouplers are widely used in various

industrial applications. As an interface, they link the controller, e.g.

PLC (programmable logic controller), PC or field bus systems to

the sensor/actuator level. Here, they have various functions:

switching AC or DC loads with different resistive, inductive and

capacitive parts, switching voltages from a few mV up to 250

V, switching currents from a few mA up to 16 A, amplification of

weak control signals, electrical isolation of control and load cir-

cuits, and signal multiplying.

6 Logic relays, CL range

CL range logic relays are suitable for small and medium-sized

control tasks and can substitute logic wiring quickly and easily.

Three different ranges are available: stand alone, expandable and

the display systems.

Time relays, CT range

Three ranges of electronic timers provide timing functions for all

applications: the CT-D range with a width of just 17.5 mm; the

CT-E range, the ideal solution for serial applications; and the CT-S

range that has two different types of connection terminals and is

ideally suited for universal use. The CT range has a wide varity of

timing functions (from ON or OFF delay to star-delta changeover).

The time relays are available with output relays, solid-state outputs

and precise direct time adjustment.

1

2

ABB Low voltage Control Products | Electronic products and relays 97

2

ABB Low voltage Control Products | Pilot Devices 105

Pilot Devices Offering

ABB Pilot Devices offers both a Modular and Compact Range of

Pushbuttons. Both feature the same front-of-panel design and

appear consistent when combined.

Modular Range, features a wide range of operators that can be

-

Compact Range features an all-in-one construction and rugged

Pilot Devices

Standard and approvals

IEC / EN 60947-1 Low-voltage switchgear and controlgear - Part 1: General rules

IEC / EN 60947-5-1 Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electro-mechanical control circuit devices

IEC / EN 60947-5-5 Low-voltage switchgear and controlgear - Part 5-5: Control circuit devices and switching elements - Electri-

function

IEC / EN 60073

IEC / EN 60529

EN 50013 Low-voltage switchgear and controlgear for industrial -

ticular control switches

DIN 40050-9protection against foreign objects; water and con-

UL 508

CSA C22.2 No 14

Environmental data

Degrees of protection

Pilot device: IEC/EN DIN UL/CSA

Pushbutton IP66, IP67 and IP69K

Selector switch IP66, IP67 and IP69K

Pilot light IP66, IP67 and IP69K

IP66, IP67 and IP69K

IP20

Temperature

Ambient temperature during operation -25 to +70 °C

Storage temperature -40 to +85 °C

Technical data

Cable connections

Operator Cable terminal

PushbuttonSelector switch

Plus-minus Pozidriv No. 2Connectable area:

2

2

Tightening torque

Operators, M22

Pushbutton and selec-tor switch

Cable terminals M3, 0.8 Nm

Pilot light Cable terminals M3.5, 0.9 Nm

Cable terminals M3, 0.8 Nm

Electrical data

Electrical ratings

Contacts

Ratings as per IEC 60947-5-1

Rated insulation volage, Ui 300 V

Rated thermal current, Ith 5 A

Rated operational current, Ieat: 240 V 1 A

Rated operational current, Ie at: 24 Vat: 125 V

0.3 A0.2 A

Ratings as per UL, CSA, NEMA C300 AC

R300 DC

Rated insulation voltage 250 V 250 V

Rated thermal current 2.5 A 1 A

Rated operational current at: 120 Vat: 125 Vat: 240 Vat: 250 V

1.5 A

0.75 A0.22 A

0.11 A

Short circuit protection

gG 10A

Make-and-break contacts

Pushbutton

LED’s (for both compact and modular)

Service life for LED’s means number of service hours until the brightness has been reduced down 50 %. Service life 50 000 h

Over voltage on LED’s 10 % overvolatge is acceptable without affecting the service life

Gloaming light All integrated LEDs have a function built

Mechanical data

Mechanical life

Pushbuttons, selector switches 500 000 operations

50 000 operations

NC

NO

= Closed contact

-1 -2

-3 -4

NC

NO

-1 -2

-3 -4

= Closed contact

Technical data compact range

Modular Range Modular Range

The System pro M compact® – DIN Rail Products

System Pro M

System Pro M is a modular system developed by ABB which,

is capable of meeting the requirements of the most modern

and up-to-date installations for low voltage applications.

MCBs

Miniature circuit-breakers.

RCDs

− Residual current circuit-breakers (RCCBs);

− RCD-blocks;

− Residual current circuit-breakers with overcurrent protec-

tion (RCBOs);

− Residual current relays (modular and front panel) with

external toroid.

Auxiliary elements

A whole range of accessories and auxiliary elements.

SPDs

Surge protective devices.

Protection devices

In addition to MCBs and RCDs, ABB supplies other modular

devices for protection such as fuse holders, fuses, switch

disconnectors, insulation monitoring devices etc.

Command devices

This category includes devices that are operated manually

to command the electric system: contactors, latching relays,

switch-isolators, switches, pushbuttons etc. Typically they

are installed to control lights from severeal points of the

same circuit or to pilot user devices with a high number of

operations.

Load management devices

Overload relays, load management switches, anti black-out

lamps, time switches and the other modular devices in this

category react automatically to variations of parameters and

other events in the system to allow for plant optimisation.

Measurement devices

The range of devices in this category is very wide, including

a great number of auxiliary components and accessories

that make installation in switchboards and consumer units

practical and economic.

Other devices

The System pro M compact® range also includes bells,

transformers, modular sockets etc.

Various accessories

3

ABB Low voltage Enclosures & DIN Rail Products | The System pro M compact® – DIN Rail Products 121

3

Wiring diagram and basic technical specification

printed on the front of the MCB. Save your time -

all important data available right away.

Easy product coding - easy identification

- easy life. Basic technical information

already integrated into the name.

25 mm² cage terminals, a well proven

and reliable technology.

Don’t loose what’s

important for you -

captive screws.

IP20 - finger safety.

Scratch and solvent resistant marking

due to laser printing. Easy identification

of the products in case of maintenance

or replacements.

Laser printed EAN code. Easy integration

into merchandise management systems

and quick identification of devices.

Miniature circuit-breaker (MCB)

SH200M Series

Electrical Data SH200 M

Standards IS/IEC 60898-1

Poles 1P, 2P, 3P, 4P, 1P +N, 3P +N

Tripping Characteristics B, C, D

Rated Curent 0.5A - 63 A

Rated Voltage

1P : 230/400/415 V AC

1P + N : 230 V AC

2…4P : 400/415 V AC

3P + N : 400/415 V AC

Insulation Voltage250 V AC (Phase to Ground)

440 V AC (Phase to Phase)

Max Operating Voltage1P: 253 V AC

2…4P : 440 V AC

Min Operating Voltage 12 V AC

Rated Frequency 50/60 Hz

Rated Short Circuit Capacity 10kA

Energy Limiting Class 3

Over Voltage Category (B,C upto 40A) III

Pollution Degree 2

Rated Impulse withstand Voltage4kV (Test Voltage 6.2kV at Sea Level,

5kV at 2,000 m)

Dielectric Test Voltage 2kV (50/60 Hz, 1 min)

Accessories mountable No

Technical Features

122 Miniature circuit-breaker (MCB) SH200M Series | ABB Low voltage Enclosures & DIN Rail Products

3Safe your time – all important data available

right away.

Easy product name, easy

identification, easy life.

Twin terminal for separate feeding

of busbar and conductor

Captive screws: don’t loose what’s

important for you.

IP20 - finger safety.

Easy identification of the

product and highly resistant

laser marking.

Quick identification thanks to laser printed

EAN marking.

Whatever your application need is –

applicable with a wide range of accessories.

Real contact position indication

Miniature circuit-breaker (MCB)

S200M Series

Electrical Data S200 M

Standards IEC 60947-2, IS/IEC-60898-1

Poles 1P, 2P, 3P, 4P, 1P +N, 3P +N

Tripping Characteristics B, C, D

Rated Curent 0.5A - 63 A

Rated Voltage

1P : 230 / 400 V AC

1P + N : 230 V AC

2…4P : 400 V AC

3P + N : 400 V AC

1P : 60 V DC

2P : 120 V DC

Insulation Voltage250 V AC (Phase to Ground)

500 V AC (Phase to Phase)

Max Operating Voltage1P: 253 V AC

2…4P : 440 V AC

Min Operating Voltage 12 V AC

Rated Frequency 50/60 Hz

Rated Short Circuit Capacity 10kA

Energy Limiting Class (B, C upto 40 A) 3

Over Voltage Category III

Pollution Degree 2

Rated Impulse withstand Voltage4kV (Test Voltage 6.2kV at Sea Level,

5kV at 2,000 m)

Dielectric Test Voltage 2kV (50/60 Hz, 1 min)

Accessories mountable Yes

Cross-section of conductor (top / bottom) 35 mm2

Terminal Fail safe bi-directional cylinder - lift terminal

Contact position indication Marking on toggle (1 ON / 0 OFF), Real CPI (red ON / green OFF)

Real Contact position indication Red ON / green OFF

Technical Features

ABB Low voltage Enclosures & DIN Rail Products | Miniature circuit-breaker (MCB) S200M Series 127

S200 M DC MCB in System pro M compact range impresses

with its performance range, approvals and high inbuilt short

circuit breaking capacity in DC applications. S200 M DC

MCBs can be used in 1-pole version at 220V DC and

in 2-pole version up to 440V DC. During the installation

process it is necessary to take into account, the polarity

marked on the device.

NEW

3

Miniature circuit-breaker (MCB)

S200M DC - MCB for DC applications

Electrical Data S200 M DC

Standards IEC / EN 60947-2

Poles 1P, 2P

Tripping Characteristics Curve C

Rated Curent 1A - 63 A

Rated Voltage 1P : 220 V DC 2P : 440V DC

Maximum Power frequency recovery Voltage, Umax 1P : 250V DC 2P : 500V DC

Min Operating Voltage 12 V DC

Rated Ultimate short-circuit breaking Capacity, Icu 10kA

Rated Service short-circuit breaking Capacity, Ics 10kA

Cross-section of conductor (top / bottom) 35 mm2

Terminal Fail safe bi-directional cylinder - lift terminal

Contact position indication Marking on toggle (1 ON / 0 OFF), Real CPI (red ON / green OFF)

Real Contact position indication Red ON / green OFF

Accessories mountable Yes (All System ProM Compact accessorries)

Housing Insulation group I, RAL 7035

Toggle Insulation group II, black ,sealable

Ambient temperature -25!…..+55!C

Storage temperature -40!…..+70!C

Torque 2.8 Nm

Screwdriver No. 2 Pozidrive

Mounting On DIN rail 35 mm acc. to EN 60715 by fast clip

Mounting position any

Mounting dimensions acc. To DIN 43880 1

Pole dimensions ( H X D X W ) 85 X 69 X 17.5

Pole weight approx. 125g

Technical Features

m pro M compact range impr

approvals and high inbuilt

DC applications. S200 M D

pole version at 220V DC an

2-pole version up to 440V DC.

ocess it is necessary to take into

132 Miniature circuit-breaker (MCB) S200M DC - MCB for DC applications | ABB Low voltage Enclosures & DIN Rail Products

3

Technical Data FH200

Standards IEC/EN 61008

Type (wave form of the earth leakage sensed) AC

Poles 2P, 4P

Rated current In 25, 40, 63 A

Rated sensitivity I∆n 30, 100, 300 mA

Rated voltage Ue 230/400 - 240/415 V

Insulation voltage Ui 500 V

Max. operating voltage of circuit test 254 V

Min. operating voltage of circuit test 110 V

Rated frequency 50..60 Hz

Dielectric test voltage at ind. freq. for 1 min. 2.5 kV

Mechanical features

Toggle BLACK sealable in ON-OFF position

Contact position indicator (CPI) not available

Ambient temperature (with daily average ≤ +35 °C) -5..+40 oC

Storage temperature -40…+70 oC

Installation

Terminal typeFailsafe bi-directional cylinder-lift terminal

at top and bottom (shock protected)

Terminal size top/bottom for cable 25/25 mm2

Terminal size top/bottom for busbar 10/10 mm2

Tightening torque 2.8 N*m

Connection from top and bottom

Accessories mountability No

Laser-marked order code on the front

to make easier future orders.

Information on the device are laser

printed to make them clearly visible

and long lasting.

Bi-directional cylindrical terminal ensure

higher safety of connecting operations,

making them easier.

Test pushbutton to verify the correct

functioning of the device.

Residual Current Circuit-breaker (RCCB)

FH 200 Series

ABB Low voltage Enclosures & DIN Rail Products | RCCB FH 200 Series 137

3

In=25-63 A

Two pole Four pole Four pole

In=25-40 A In=63 A

Overall dimensions

MCB - (SH200) and Isolator (SHD)

MCB - (S200)

RCCB - (F200)

DDA 200

Two pole Four pole

69

69

44

44

17.5 6.8

17.5

17.5

1 module

1 module

2 modules

2 modules

3 modules

3 modules

4 modules

4 modules

35

35

52.5

52.5

70

70

45

85

69

6.844

45

17.5 17.5 17.5

7035

17.5

88

85

45

85

43

58

67

73

17.5

35

17.5

9.7

17.5 8.75

35

85

93

34.5

8.75

17.5

17.5

17.5

10.25

17.5 17.5 17.5

70 69.5

10.25

17.5 17.5 17.5

4.85

9.2

8.1

8.1

35 69.5 69

45

44

6.8

RCBO (DS200)

6.8

45

88

148 Overall dimensions | ABB Low voltage Enclosures & DIN Rail Products

3

Solution for unwanted tripping - AP-R type (high immunity)

RCCB / RCBO

The ABB range of AP-R anti-disturbance residual current circuit-

breakers and blocks was designed to overcome the problem of

unwanted tripping due to overvoltages of atmospheric or operati-

on origin.

The electronic circuit in these devices can distinguish between

temporary leakage caused by disturbances on the mains and

permanent leakage due to actual faults, only breaking the circuit in

the latter case.

AP-R residual current circuit-breakers and blocks have a slight de-

lay into the tripping time, but this does not compromise the safety

limits set by the Standards in force (release time at 2 I∆n=150 ms).

Compared with standard type breakers, AP-R residual current

breakers are therefore characterised, for any given sensibility,

by:

- Higher residual trip current

- Tripping time delay

- Better resistance to overvoltages, harmonics and impulse

disturbances.

Guaranteeing conventional residual current protection, their

installation in the electrical circuit therefore allows any unwanted

tripping to be avoided in domestic and industrial systems in which

service continuity is essential.

This delay makes the AP-R residual current devices especially

ABB

A or AC

RCCB

ABB

B type

RCCB

ABB MCBs

Lighting ABB asynchronous motor

Cooling

Three-phasefrequencyconverter

ABB

AP-R type

RCCB

Single-phasefrequencyconverter

suited for installations involving motor starters/variable speed

drives, fluorescent lamps or IT/electronic equipment.

The use of multiple electronic reactors for the supply of fluorescent

lamps instead generates permanent leakage currents and inrush

currents that can cause nuisance tripping of a standard residual

current circuit breaker.

IT system loads and other electronic equipment (e.g. dimmers,

computers, inverters) with capacitive input filters connected bet-

ween the phases and ground can also generate permanent earth

leakage currents whose sum may provoke the nuisance tripping of

a standard residual current circuit breaker. For these situations, the

AP-R breakers allow a greater number of devices to be connected

to the installation.

Frequency converters include a rectifier section and an inverter

section.

In case of fault within a single-phase frequency converter AP-R

type RCDs provide complete protection, because an earth fault

occurring downstream the inverter, produces an earth fault current

with multi-frequency shape with high amount of harmonics.

While, in case of fault within a three-phase frequency converter, B

type RCDs ensure complete protection because in case of insula-

tion fault between the rectifier and the inverter or downstream the

inverter we can have a smooth DC earth fault current.

ABB Low voltage Enclosures & DIN Rail Products | RCCB / RCBO 143

3

Laser-marked order code on the front

to make easier future orders.

Contact position indicator (CPI): to

always know the status of the contacts

(red: closed contacts; green: open

contacts) independently on the toggle

position

Information on the device are laser

printed to make them clearly visible

and long lasting.

Bi-directional cylindrical terminal ensure

higher safety of connecting operations,

making them easier.

Test pushbutton to verify the correct

functioning of the device.

Residual Current Circuit-breaker (RCCB)

F 200 Series

Technical Data F200

Standards IEC/EN 61008

Type (wave form of the earth leakage sensed) AC A

Poles 2P, 4P

Rated current In 25, 40, 63, 80, 100 &125 A

Rated sensitivity I∆n 30, 100, 300 mA

Rated voltage Ue 230/400 - 240/415 V

Insulation voltage Ui 500 V

Max. operating voltage of circuit test 254 V

Min. operating voltage of circuit test 110 V

Rated frequency 50..60 Hz

Dielectric test voltage at ind. freq. for 1 min. 2.5 kV

Mechanical features

Toggle BLUE sealable in ON-OFF position

Contact position indicator (CPI) yes

Ambient temperature (with daily average ≤ +35 °C) -25..+55 oC

Storage temperature -40…+70 oC

Installation

Terminal typeFailsafe bi-directional cylinder-lift terminal

at top and bottom (shock protected)

Terminal size top/bottom for cable 25/25 mm2

Terminal size top/bottom for busbar 10/10 mm2

Tightening torque 2.8 N*m

Connection from top and bottom

Accessories mountability Yes

ABB Low voltage Enclosures & DIN Rail Products | RCCB F 200 Series 139

3

Distribution Boards

Elegance Series

Elegance series (E-series) Distribution Boards are available in

texture grey (Color code - RAL7035).

Construction

Blending aesthetics, functionality and safety, the E-series of

ABB Distribution Boards are manufactured with high precision,

and high quality CRCA steel sheets. These Distribution Boards

undergo a seven-tank phosphating process to ensure anti-rust

conditioning, superior finish and lasting strength. Premier quality

powder coating is applied using the latest techniques

Colour

ABB’s E-series of Distribution Boards is available in Texture Grey

(RAL 7035)

Installation

The E-Series of ABB Distribution Boards are universal Mounting

Type,hence can be flush or wall Mounted. These Distribution

Boards are provided with top and bottom removable gland plates

with adequate no of Knock outs,which enable easy installation

and connection of conduits of sizes up to 32mm dia Knock out

Protection

E-series Distribution Boards offer three types of protection-IP43

& IP54 degree with a metal door and IP30 degree without a door.

The highest degree of attention has been paid to the safety aspect

of the Distribution Boards, considering that they are installed in

close proximity to people. An intermediate plate ensures total

safety, as no live parts are exposed when the door is opened.

158 DB - Elegance Series | ABB Low voltage Enclosures & DIN Rail Products

3

Distribution Boards

Classic Series

Product Description Product Code No of Ways No of Modules M.R.P.(`)

SHC WD 4 1SYN869006R0001 4 way 4+2 998

SHC WD 6 1SYN869007R0001 6 way 6+2 1,092

SHC WD 8 1SYN869008R0001 8 way 8+2 1,222

SHC WD 10 1SYN869006R0010 10 way 10+2 1,280

SHC WD 12 1SYN869009R0001 12 way 12+2 1,556

SHC WD 14 1SYN869010R0001 14 way 14+2 1,589

SHC WD 16 1SYN869006R0016 16 way 16+2 2,009

SHC WD 20 1SYN869006R0020 20 way 20+2 2,261

Product Description Product Code No of Ways No of Modules M.R.P.(`)

SHC M 4 1SYN869001R0001 4 way 4+2 1,398

SHC M 6 1SYN869002R0001 6 way 6+2 1,545

SHC M 8 1SYN869003R0001 8 way 8+2 1,821

SHC M 10 1SYN869004R0101 10 way 10+2 1,851

SHC M 12 1SYN869004R0001 12 way 12+2 2,108

SHC M 14 1SYN869005R0001 14 way 14+2 2,288

SHC M 16 1SYN869001R0016 16 way 16+2 2,731

SHC M 20 1SYN869001R0020 20 way 20+2 3,089

SPN DB - SHC

IP 30

IP 43 with metal Door

ABB Low voltage Enclosures & DIN Rail Products | DB - Classic Series 167

Classic Series Distribution Boards are available in Ivory colors (Color code - RAL9010)

The range of ABB Low Voltage Capacitors and Filter modules

ranks amongst the most extensive on the market with a

full range of innovative solutions for various applications,

helping to optimise resources, reduce energy costs, boost

productivity.

– Q Cap - L (normal duty and heavy duty) capacitors

– Cylindrical type

– Box type

ABB Low voltage Capacitors and Filter modules | ABB’s comprehensive range of Low Voltage Capacitors and Filter modules 191

– CLMD heavy duty capacitors

– Filter modules

– APFC relays

– APP capacitors

ABB’s comprehensive range of Low Voltage Capacitors and Filter modules

5

Compact HomeTechnical catalog

2CSC400003B0202

ABB

2

1

2

3

Summary

1/1

Introduction

Application sheets

Selection tables

ABB

1 The ABB Line Protection Devicesquality system is conforming with the ISO 9001

Vision 2000international Standard (model for quality

assurance as regardsdesign, development, construction, installation

and service) andto the equivalent EN ISO 9001 European

Standard.ABB commitment to protecting the

environment is also shownin concrete way by the Life Cycle Assessments

of the products, which isbeing realized directly by ABB Research and

Development.All the products of Compact Home range are

conforming to theEuropean standards 2002/95/CE regarding

the restrictions on theuse of certain dangerous substances

in the electricaland electronical equipments.

It is necessary to respect the local regulationsconcerning the elimination

of the packaging materials and of thecircuit-breakers and,

if possible, to recycle them.The symbol marked on the product means

that the circuit breaker mustnot be eliminated together with the general

litter.

ABB

1

1/3

All Compact Homedevices comply toEuropean andinternational productstandards:• IEC/EN 61008 (RCCBs)• IEC/EN 61009 (RCBOs)• IEC/EN 60898 (MCBs)• IEC/EN 60947-3

(Switches)• IEC/EN 60669-1

(Dimmers)• IEC/EN 61643-11

(SPDs)• IEC/EN 60730-1

(Timers)• IEC/EN 61558-1-2-8

(Transformers)• IEC/EN 60439-1

(Busbars)They are also conformingto the following ECdirectives:• Low Voltage Directives

(LVD) no. 73/23 EEC• Electromagnetic

Compatibility Directive(EMC) no.89/336 EECand 92/31 EEC

CE marking of CompactHome devices warrantsfree circulation and sale inEuropean Union. It isrealized on supplier’sresponsibility, in additionto this marks andapprovals, guaranteefunctioning, compatibilityand safety conforming tonational and internationalStandards.ABB Compact HomeRCDs also obtained thefollowing national andinternational approvals:

Thanks to these approvals,the devices can be usedwithout restriction as devicesfor the world market.

AENOR- ES APCER- PT

GOST- RU

SIRIM- MY

TICKMARK- AULCIE- FR

CCC- CN SABS - ZA PSB - SG

Compact Home

ABB

1

1/4

1

Introduction

Family: F 200 = RCCBs

H for HOME

N° of poles: 2; 4

Current:25A; 40A; 63A

Sensitivity:0,03A, 0,1A …

Indication ofdevice’s ratedvoltage

Indication of shortcircuit coordinationperformance:Im=Idm=1000AInc=6000kA with agL 63A fuse

Wiring diagrams toprevent from awrong connection

Failsafe bi-directional cylinder-liftterminal at top and bottom

Indication of the marks andapprovals the devices have beenobtained

Test button to be tested monthly

Type: AC, A

Black toggle to identify CompactHome range

Laserprint on side of mounting

instruction and of the symbol which means that the circuit-breaker must be thrown awayseparately

ABB identity number for a quicklyidentification of the product

for more information about this products, see the technical catalogue

Compact Home

ABB

1

1/5

Introduction

Cage terminals up and bottom

Family: S 200 = MCBs

H for HOME

N° of poles:1; 1+N; 2; 3; 3+N; 4

Breakingcapacities:T=3kA, L=4.5kA,no-one=6kA

Characteristic: B, C

Rated current:6A; 10A; … 63A

Indication of MCB ratevoltage

Indication of MCBbreaking capacity andlimitation class

Wiring diagrams to prevent wrongconnection on all pole versions

for more information about this products, see the technical catalogue

Compact Home

2

Application sheets

2/1ABB

Index

Basic solution for consumer units installed in a little flat (<35 m2) ..........................................2/2

Advanced solution for consumer units installed in a little flat (<35 m2) ...................................2/3

Basic solution for consumer units installed in a big flat (between 35 and 100 m2) .................2/4

Advanced solution for consumer units installed in a big

flat (between 35 and 100 m2) ..................................................................................................2/6

Basic solution for consumer units installed in an indipendent

house/villa (>100 m2) ..............................................................................................................2/8

Advanced solution for consumer units installed

in an indipendent house/villa (>100 m2) ................................................................................2/10

Notes for use, special features .............................................................................................2/12

Technical features of MCBs SH 200 series ...........................................................................2/14

2

2/2 ABB

Compact Home

RCCB 25A30mA

1PC 10

1PC 16

Application sheetsBasic solution for consumer units installed ina little flat (<35 m2)

The simplest possible solution:1 RCCB I n=30mA: protection alsoagainst direct contacts2 MCBs: one with In=10A to protectlights circuit and one with In=16A toprotect sockets circuit

2

2/3ABB

Compact Home Application sheetsAdvanced solution for consumer units installed ina little flat (<35 m2)

OVR

RCCB 25A30mA

TSM 2PC 20

1PC 16

RCBO C16 30mA

1PC 16

1PC 16

1PC 10

1 RCCB I n=30mA: protection alsoagainst direct contacts3 MCBs with In=16A protect sockets inthe living room and in the kitchen (e.g.for the oven)1 MCB with In=10A protects lightscircuit of the whole house1 modular bell with built-in voltagetransformer for doorbell’s acousticsignal

In this consumer unit it has beenintroduced a third level of protectionwith an OVR (upstream protectedby a MCB) to protect installation andappliances against transientovervoltage peaks.Bathroom, due to the damp whichcharacterizes it, is considered acritical area: in the suggestedsolution, the dedicated protection of1 RCBO (with In=16A andI n=30mA) improves service’scontinuity and protects bathroom’ssockets against earth-fault current,overloads and short-circuits.

2

2/4 ABB

Compact Home Application sheetsBasic solution for consumer units installed in a big flat(between 35 and 100 m2)

1 MCB used as main switch of theconsumer unit3 RCCBs: one with In=40A protectssockets circuit of the living room,kitchen and laundry-room and twowith In=25A protect respectivelysockets circuit of the bedrooms andbathroom and lights circuit of thewhole house2 MCBs In=10A protect lights circuitsof bedrooms and bathroom separatelyfrom lights circuits of the rest of thehouse6 MCBs In=16A (3 per RCCB) protectsockets1 OVR protects against transientovervoltage peaks

In this consumer unit has beenintroduced some typical function ina modular shape: a voltagetransformer (TS) supplies a bell(SM) for doorbell’s acoustic signaland a buzzer (RM) for emergencyacoustic signal in the bathroom.

2P63A

RCCB 25A30mA

RCCB 40A30mA

RCCB 25A30mA

1PC 10

1PC 10

1PC 16

1PC 16

2PC 20A

1PC 16

TS

1PC 16

1PC 16

1PC 16

OVR RM

SM

2

2/5ABB

Compact Home Application sheetsBasic solution for consumer units installed in a big flat(between 35 and 100 m2)

2

2/6 ABB

Compact Home Application sheetsAdvanced solution for consumer units installed in a big flat(between 35 and 100 m2)

1 MCB used as main switch of theconsumer unit2 RCCBs: one with In=40A protectssockets circuit and electric householdappliances in the kitchen and onewith In=25A protects remainingsockets and all the other devices2 RCBOs protect separately socketscircuits of the bathroom and of thelaundry10 MCBs In=16A or In=10A protectsockets and lights circuits of thehouse1 OVR protects against transientovervoltage peaks1 modular bell with built-in voltagetransformer for doorbell’s acousticsignal1 LSS1/2 for load management

In this consumer unit a DTS-TWS(time switch + twilight switch)allows the time programming of theexternal and entrance lights inrelation to the environmental lightlevel. One E 259 (installation relay),equipped with contact positionindicator, allows the manual controlof the boiler in the bathroom.

RCCB 40A30mA

1PB 10

1PB 10

1PB 10

LSS 1/2

1PB 16

1PB 16

1PB 16

3PB 40

1PB 16

1PB 16

3 PB 16

1PC 16

2PC 20A

TS TM 1PC 16

1PB 16

DTS - TWS

OVR SMRME 259

3P 40A

RCBO B16A 30mA

RCBO B16A 30mA

RCCB 25A30mA

2

2/7ABB

Compact Home Application sheetsAdvanced solution for consumer units installed in a big flat(between 35 and 100 m2)

2

2/8 ABB

Compact Home Application sheetsBasic solution for consumer units installed in an indipendenthouse/villa (>100 m2)

1PC 16

1PC 16

DTS - TWSTS

SM

LSS 1/2

RCBO C 2530 mA

E 200i

RCBO C 1630 mA

RM

1PC 16

1PC 16

1PC 16

1PC 16

E 259

1PC 10

1PC 10

RCCB 40A30mA

4P C 63A

1PC 16

RCCB 4P40A 30mA

RCCB 4P40A 30mA

1PC 16

1PC 16

1PC 16

1PC 10

3 PC 20

OVR

1 MCB used as main switch of theconsumer unit3 RCCBs with In=40A protect socketsand lights circuits of the house2 RCBOs protect separately socketsin the garage and in the swimmingpool13 MCBs In=16A or In=10A protectsockets and lights circuits of thehouse1 OVR protects against transientovervoltage peaks1 modular bell and 1 buzzer foracoustic signals1 DTS-TWS for lights timeprogramming1 E 259 for manual controlling of theboiler

In this consumer unit the E 200i isused as main disconnecting meansof the external circuit (which, forexample, can be used for thesockets or the pump of theswimming pool, always turned offduring the winter). The LSS1/2 is aload shedding switch: it avoids thetripping of the main circuit-breakerthrough switching-off in sequence ofmaximum two not primary loadswhen the preset threshold isexceeded (it could be useful to setrefrigerator as primary load towarrant service’s continuity).

2

2/9ABB

Compact Home Application sheetsBasic solution for consumer units installed in an indipendenthouse/villa (>100 m2)

2

2/10 ABB

Compact Home Application sheetsAdvanced solution for consumer units installed in anindipendent house/villa (>100 m2)

1 MCB used as main switch of theconsumer unit3 RCCBs protect sockets and lightscircuits of the house6 RCBOs protect separately thecritical lines of the house13 MCBs In=16A or In=10A protectsockets and lights circuits of thewhole house1 OVR protects against transientovervoltage peaks1 modular bell and 1 buzzer foracoustic signals1 LSS1/2 for the load management ofthe electric household appliances inthe kitchen1 E 200i separately controls theexternal sockets1 DTS-TWS for lights timeprogramming1 E 259 for manual controlling of theboiler

In the living room, the E 255(latching relay) allows the lightsequential control through a singlepushbutton circuit. The E 232(staircase timer) permits thelighting time delay in the garage,so it is not possible to forget lightturned on.

1PC 10

1PC 10

E 255

E 232 3 PC 20

1PC 16

TS TR 1PC 16

DTS - TWS

SMRM

LSS 1/2

RCBO C 1610mA

RCBO C 1610mA

RCBO C 4030mA

RCBO C 1630mA

RCBO C 2530 mA

E 200i

RCBO C 1630 mA

1PC 16

1PC 16

1PC 16

1PC 16

1PC 16

1PC 16

E 259

1PC 10

1PC 10

RCCB 40A30mA

4P C 63A

1PC 16

RCCB 4P40A 30mA

RCCB 4P40A 30mA

OVR

2

2/11ABB

Compact Home Application sheetsAdvanced solution for consumer units installed in anindipendent house/villa (>100 m2)

The MCB’s Compact Home

are equiped with 25 mm2

cage terminals, a well proven

and reliable technology.

The terminals accept not only

single wires, but as well several

conductors of the same size

e.g. 6 x 1.5 mm2 or even

conductors with different

cross sections e.g. 1 x 6 mm2

and 1 x 2.5mm2.

The cross wiring can easily

be done by inserting the

Compact Home busbars

and then the incoming

wires into one of the

MCB’s terminals.

The terminals accept Compact

Home busbars and conductors up

to 16 mm2 together.

Easy to handle –

When Compact Home

RCCB’s or E 200- isolators

are used as main incomers

the Compact Home busbars

perfectly fit into all possible

combinations.

Compatibility with

pro M compact is given in all

kind of variations like:

Insertion of 1 pro M compact

MCB (e.g. K-characteristic)

into an Installation with

Compact Home components

and Compact Home busbars.

Also the combination of

1 Compact Home MCB with

pro M compact components

and pro M compact busbars

is not a problem.

– Compact Home

2

2/14 ABB

Compact Home Technical featuresof MCBs SH 200 series

SH 200

SH 200 T SH 200 L SH 200

Standards IEC/EN 60898Rated current in A 6 - 40Poles 1, 2, 3, 4, 1+NA, 3+NARated Voltage Ue IEC 1P, 1P+N V 230

IEC 2P, 3P, 3P+N, 4P V 230/400Insulation voltage Ui V 250Max. operating voltage Ub max. IEC AC V 254/440Min. operating voltage Ub min. V 12 V AC - 12 V DCRated frequency Hz 50…60Rated breaking capacity acc. to IEC/EN 60898 ultimate Icn A 3000 4500 6000Rated impulse withstand voltage (1.2/50) Uimp KV 4 (test voltage 6,2. at sea level

5 at 2000 m)Dielectric strength at power freq. for 1 min. KV 2,5Overvoltage category IIIPollution degree 2Thermomagnetic release B: 3 In Im 5 In • • •characterisitic C: 5 In Im 10 In • • •Toggle black sealable in ON-OFF positionElectrical life 10000Mechanical life/operations 20000Protections degree/operations housing IP4X

terminals IP2X

Mechanical shock resistance 30 g - 2 shocks - duration 11 msResistance to vibrations acc. to IEC/EN 60060-2--6 5 g - 20 cycles at frequency

5…150…5 Hz with 0,8 x InTropicalization humid heat °C/RH 28 cycles with 55/95…100acc. to IEC/EN 60068-2 constant climatic conditions °C/RH 23/28 - 40/93 - 55/20

variable climatic conditions °C/RH 25/95 - 40/95Reference temperature for setting of thermal element °C 30Ambient temperature (with daily averages +35°C) IEC °C -25…+55Storage temperature °C -40…+70Terminal type cage terminalTerminal size top/bottom for cable IEC mm2 25/25

UL/CSA AWG 18-4Tightening torque IEC N*m 2.5

UL/CSA in-lbs. 22Tool Nr. 2 PozidrivMounting on DIN rail EN 60715 (35 mm) by

means of fast clip deviceMounting position optionalConnection from top and bottomPole dimensions (H x D x W) mm 85 x 69 x 17.5Pole weight g 125

Electricalfeatures

Mechanicalfeatures

Installation

Dimensionsand weigh

Tripping diagrams

Tripping characterisitc Bacc. to DIN VDE 0641 part 11In = 6 … 40 ASH 200 T / SH 200 L / SH 200

Tripping characterisitc Cacc. to DIN VDE 0641 part 11In = 0.5 … 40 ASH 200 T / SH 200 L / SH 200

2CD

C02

2188

F020

5

2CD

C02

2190

F020

5

2

2/15ABB

� The tripping for the electromagnetic trip are valid for AC 50… 60 Hz.For other frequencies see table below.

� From warm operating condition (After I1 > 1 h resp. 2 h)

Thermal trips � Electromagnetic trips �

acc. to Tripping Test currents: Tripping- Test currents: Tripping-characterisitic Low test High test time hold current trip time

current current surges of at least atI1 I2

1.13 · In > 1 h 3 · In 0.1 s … 45 s 32 A / 0.1 s … 90 s 32 A1.45 · In < 1 h 5 · In < 0,1 s

1.13 · In > 1 h 5 · In 0.1 s … 45 s 32 A / 0.1 s … 30 s 32 A1.45 · In < 1 h 10 · In < 0,1 s

Compact Home

Internal resistances and power losses of the Miniature Circuit-Breakers

Internal resistances per pole in mPower losses per pole in W

Type Rated Range SH 200 T Range SH 200 L Range SH 200current B, C B, C B, CA m W m W m W

SH 200 6 55 2.0 55 2.0 55 2.08 15 1.0 15 1.0 15 1.0

10 13.3 1.3 13.3 1.3 13.3 1.3

13 13.3 2.3 13.3 2.3 13.3 2.316 7.0 1.8 7.0 1.8 7.0 1.820 6.25 2.5 6.25 2.5 6.25 2.5

25 5.0 3.2 5.0 3.2 5.0 3.232 3.6 3.7 3.6 3.7 3.6 3.740 3.0 4.8 3.0 4.8 3.0 4.8

Tripping characteristics

B

C

� Influence of ambient temperature see below.

Influence of frequency on electromagnetic trips

The stated tripping values of the electromagnetic trips are valid for afrequency of 50… 60 Hz. In case of frequencies deviating from 50… 60Hz as well as direct current the tripping values are changed by thefactor mentioned below.

The tripping values of the thermal trips are independent of the frequency

Influence of ambient temperature

The thermal trips are calibrated for an ambient temerpature30 °C for B- and C-characteristic.

In the case of temperatures deviating from these values the trippvalues• are reduced in case of higher temperatures• are increased in case of lower temperatures

The electronic tripping is not dependent on temperature

AC DC100 Hz 200 Hz 400 Hz

Factor approx. 1.1 1.2 1.5 1.5

IEC/EN 60898

2

2/16 ABB

Load data from diagram Calculation Example

Rated current and characteristics of M.C.B. In / B, C 16 A – BContinuous load R 40 °CNumber of M.C.B.´s / Mounting distance N / X 8 pieces / 0 and 8 mm

Load 1 h 1 a resp. 1 b I = In · K 16 · 1.07 = 17.1 A

Continuous load > 1 h I = 0.9 · In · K 0.9 · 16 · 1,07 = 15.4 A

Continuous load, N M.C.B.´s, Distance 0 2 I = 0.9 · K · KN 0.9 · 16 · 1.07 · 0.77 = 11.9 AContinuous load, N M.C.B.´s, Distance X 3 I = 0.9 · K · KX 0.9 · 16 · 1.07 · 0.98 = 15.1 A

Compact Home

Current-carrying capacity of the MCB´s as a function of the ambient temperature

Mutual thermal influence in the case of simultaneous load

MCB´s mounted in a row side bay side MCB´s mounted with a seperating distance X

SK

008

0 Z

93

SK

007

8 Z

93

Max. operating current depending on the ambient temperature of a circuit-breaker in load circuit of characteristics type B, C and D

B, C Ambient temperature T (°C)In (A) -30 -20 -10 0 10 20 30 40 50 606.0 7.7 7.5 7.2 6.9 6.6 6.3 6.0 5.7 5.3 4.9

8.0 10.3 10.0 9.6 9.2 8.8 8.4 8.0 7.5 7.1 6.5

10.0 12.9 12.5 12.0 11.5 11.1 10.5 10.0 9.4 8.8 8.2

13.0 16.8 16.2 15.6 15.0 14.4 13.7 13.0 12.3 11.5 10.6

16.0 20.7 20.0 19.2 18.5 17.7 16.9 16.0 15.1 14.1 13.1

20.0 25.8 24.9 24.0 23.1 22.1 21.1 20.0 18.9 17.6 16.3

25.0 32.3 31.2 30.0 28.9 27.6 26.4 25.0 23.6 22.0 20.4

32.0 41.3 39.9 38.5 37.0 35.4 33.7 32.0 30.2 28.2 26.1

40.0 51.6 49.9 48.1 46.2 44.2 42.2 40.0 37.7 35.3 32.7

2

2/17ABB

SH 200 T /SH 200 L / B/C Max. Back-up protectionSH 200 Rated current fuse Main Circuit Breaker S 700

6/8 63 A 100 A10… 32 100 A 100 A

40 125 A 100 A

Max. Back-up protection

Compact Home

Maximum permissible earth-fault loop impedance Zs at U0 = 230 V ̃ �

to ensure compliance with the operation conditions pursuant to IEC 60364-4.Operating time < 0.4 s; at 400 V ˜ < 0.2 s and at > 400 V ˜ < 0.1 sThe instantaneous release of the MCB ensures an operating time of 0.1 s (TN system).Determined according to DIN VDE 0100-520 sheet 2:2002-11 (source impedance = 300 , c = 0.95 and conductortemperature 70 °C = factor 0.8). The internal resistance of the MCB is already included.

SH 200, SH 200 L, SH 200 T

Rated B Ccurrent In A max. Zs max. Zs

6 7.7 3.8

8 – 2.8

10 4.6 2.2

13 3.5 1.7

16 2.9 1.4

20 2.3 1.2

25 1.8 0.9

32 1.4 0.7

40 1.1 0.6

� U0 = rated voltage against earthed conductor; for U0 = 240 V ̃ is Zs · 1.04; for U0 = 127 V ̃ is Zs · 0.55

Take into account the voltage drop:e.g. in the case of a 1.5 mm2 conductor, protected by a B 16 circuit breaker, the maximum cable length is 82 m.If the voltage is below 3%, this would result in a maximum cable length (2-strand) of 17 m.For more details on this topic, get your own copy of the technical information leaflet “Maximum cable lengths”.

Maximum cable length is the case of different voltages and cross sections on request.

2

2/18 ABB

short circuit discrimination in kA

to main circuit breaker S 700 to fuse gL/gG(DIN VDE 0636; IEC 269/3)

16 20 25 35 40 50 63 80 100 16 20 25 35 50 63 80 100 125 160

4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 0.2 0.4 0.6 1.5 2.5 2.8 3 3 3 34,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 0.3 0.6 1.4 2.4 2.6 3 3 3 34,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 0.5 1.2 2.1 2.5 2.8 3 3 34,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 0.4 1.0 1.8 2.4 2.8 3 3 34,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 0.8 1.6 2.3 2.8 3 3 3

4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 1.5 2.1 2.5 2.5 3 34,5 4,5 4,5 4,5 4,5 4,5 4,5 1.0 2.0 2.5 2.5 3 3

4,5 4,5 4,5 4,5 4,5 4,5 1.9 2.5 2.5 3 34,5 4,5 4,5 4,5 4,5 1.5 2 2 2 2

6 6 6 6 6 6 6 6 6 0.2 0.4 0.7 1.8 3 5 4.5 4.5 4.5 4.56 6 6 6 6 6 6 6 6 0.2 0.3 0.6 0.6 2.5 4 4.5 4.5 4.5 4.56 6 6 6 6 6 6 6 6 0.3 0.6 1.4 2.3 3 4 4.5 4.5 4.56 6 6 6 6 6 6 6 6 0.5 1.3 2 3 4 4.5 4.5 4.56 6 6 6 6 6 6 6 6 1 1.8 2.5 3.5 4.5 4.5 4.5

6 6 6 6 6 6 6 6 1.6 2.2 3 4 4.5 4.56 6 6 6 6 6 6 1.5 2.2 3 4 4.5 4.5

6 6 6 6 6 6 2 2.8 3.5 4.5 4.56 6 6 6 6 2 2.5 3 4.5 4.5

10 10 10 10 10 10 10 8 8 0.2 0.5 0.8 2 3.3 5.5 6 6 6 610 10 10 10 10 10 10 8 8 0.2 0.4 0.7 1.7 2.8 4.5 6 6 6 610 10 10 10 10 10 10 8 8 0.2 0.4 0.7 1.5 2.5 3.5 5 6 6 610 10 10 10 10 10 10 8 8 0.7 1.5 2.5 3.5 5 6 6 6

10 10 10 10 10 10 8 8 1.3 2 2.9 4.1 6 6 610 10 10 15 10 8 8 1.8 2.6 3.5 5 6 6

10 10 10 10 8 8 1.8 2.6 3.5 5 6 610 10 10 8 8 2.2 3 4 6 6

Compact Home

Short circuit selectivity: In the case of a short circuit, selectivity exists up to the values indicated.

MCBs

series

SH 200 T – B, C

SH 200 L – B, C

SH 200 – B, C

SK 0112 Z 99 SK 0113 Z 99

no selectivity

no selectivity**

**

68

1013162025324068

1013162025324068

101620253240

**

InA

** Limited or no selectivity at all possible in the overload range (thermal tripping)

The above values require that, in the case of multi-phase installations, that the last cb be feed from above.

ABB 3/1

Selection tables

3

Index

Selection tables of MCBs SH 200 series

SH 200 T-B ..............................................................................................................................3/2

SH 200 T-C .............................................................................................................................3/4

SH 200 L-B .............................................................................................................................3/6

SH 200 L-C .............................................................................................................................3/8

SH 200 B ...............................................................................................................................3/10

SH 200 C ..............................................................................................................................3/12

Selection tables of RCCBs FH 200 series

FH 200 ..................................................................................................................................3/14

Selection tables of RCBOs DS9 series

DS9 .......................................................................................................................................3/15

Selection tables of busbars

Busbars .................................................................................................................................3/16

Selection tables of MDRCs

E 200i switches .....................................................................................................................3/17

E 232 staircase lighting time delay switches .........................................................................3/18

LSS 1/2 load shedding switches ...........................................................................................3/18

TM/TS bell transformers .......................................................................................................3/18

SM/RM bells and buzzers .....................................................................................................3/18

DTS digital time switches ......................................................................................................3/18

E 259 installation relays ........................................................................................................3/18

E 250 latching relays .............................................................................................................3/18

OVR surge protection devices ..............................................................................................3/18

3/2 ABB

3

Compact Home

SH 200 T B characteristicFunction: protection and control of the circuits against overloads and short-circuits; protection forpeople and big-length cables in TN and IT systems.

Applications: buildings, both residential and commercial

Standard: IEC/EN 60898

Icn=3kA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 6 SH 201 T-B 6 2CDS 231 001 R0065 63192 1 0.125 10

10 SH 201 T-B 10 2CDS 231 001 R0105 63195 2 0.125 10

13 SH 201 T-B 13 2CDS 231 001 R0135 63197 6 0.125 10

16 SH 201 T-B 16 2CDS 231 001 R0165 63199 0 0.125 10

20 SH 201 T-B 20 2CDS 231 001 R0205 63201 0 0.125 10

25 SH 201 T-B 25 2CDS 231 001 R0255 63203 4 0.125 10

32 SH 201 T-B 32 2CDS 231 001 R0325 63205 8 0.125 10

40 SH 201 T-B 40 2CDS 231 001 R0405 63207 2 0.125 10

2 6 SH 202 T-B 6 2CDS 232 001 R0065 63226 3 0.25 5

10 SH 202 T-B 10 2CDS 232 001 R0105 63229 4 0.25 5

13 SH 202 T-B 13 2CDS 232 001 R0135 63231 7 0.25 5

16 SH 202 T-B 16 2CDS 232 001 R0165 63233 1 0.25 5

20 SH 202 T-B 20 2CDS 232 001 R0205 63235 5 0.25 5

25 SH 202 T-B 25 2CDS 232 001 R0255 63237 9 0.25 5

32 SH 202 T-B 32 2CDS 232 001 R0325 63239 3 0.25 5

40 SH 202 T-B 40 2CDS 232 001 R0405 63241 6 0.25 5

3 6 SH 203 T-B 6 2CDS 233 001 R0065 63243 0 0.375 1

10 SH 203 T-B 10 2CDS 233 001 R0105 63246 1 0.375 1

13 SH 203 T-B 13 2CDS 233 001 R0135 63248 5 0.375 1

16 SH 203 T-B 16 2CDS 233 001 R0165 63250 8 0.375 1

20 SH 203 T-B 20 2CDS 233 001 R0205 63252 2 0.375 1

25 SH 203 T-B 25 2CDS 233 001 R0255 63254 6 0.375 1

32 SH 203 T-B 32 2CDS 233 001 R0325 63256 0 0.375 1

40 SH 203 T-B 40 2CDS 233 001 R0405 63258 4 0.375 1

4 6 SH 204 T-B 6 2CDS 234 001 R0065 63277 5 0.5 1

10 SH 204 T-B 10 2CDS 234 001 R0105 63280 5 0.5 1

13 SH 204 T-B 13 2CDS 234 001 R0135 63282 9 0.5 1

16 SH 204 T-B 16 2CDS 234 001 R0165 63284 3 0.5 1

20 SH 204 T-B 20 2CDS 234 001 R0205 63286 7 0.5 1

25 SH 204 T-B 25 2CDS 234 001 R0255 63288 1 0.5 1

32 SH 204 T-B 32 2CDS 234 001 R0325 63290 4 0.5 1

40 SH 204 T-B 40 2CDS 234 001 R0405 63292 8 0.5 1

UBmax

440 V ~ 60 V ...

UBmax

440 V ~125 V ...①

UBmax

440 V ~

UBmax

440 V ~125 V ...①

① UBmax 125 V ... with 2 poles connected in series

Selection tables SH 200 T-BMCBs SH 200 series T3000

B

3/3ABB

3

Compact Home

With disconnecting neutral NA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 + NA 6 SH 201 T-B 6 NA 2CDS 231 103 R0065 63209 6 0.25 5

10 SH 201 T-B 10 NA 2CDS 231 103 R0105 63212 6 0.25 5

13 SH 201 T-B 13 NA 2CDS 231 103 R0135 63214 0 0.25 5

16 SH 201 T-B 16 NA 2CDS 231 103 R0165 63216 4 0.25 5

20 SH 201 T-B 20 NA 2CDS 231 103 R0205 63218 8 0.25 5

25 SH 201 T-B 25 NA 2CDS 231 103 R0255 63220 1 0.25 5

32 SH 201 T-B 32 NA 2CDS 231 103 R0325 63222 5 0.25 5

40 SH 201 T-B 40 NA 2CDS 231 103 R0405 63224 9 0.25 5

3 + NA 6 SH 203 T-B 6 NA 2CDS 233 103 R0065 63260 7 0.5 1

10 SH 203 T-B 10 NA 2CDS 233 103 R0105 63263 8 0.5 1

13 SH 203 T-B 13 NA 2CDS 233 103 R0135 63265 2 0.5 1

16 SH 203 T-B 16 NA 2CDS 233 103 R0165 63267 6 0.5 1

20 SH 203 T-B 20 NA 2CDS 233 103 R0205 63269 0 0.5 1

25 SH 203 T-B 25 NA 2CDS 233 103 R0255 63271 3 0.5 1

32 SH 203 T-B 32 NA 2CDS 233 103 R0325 63273 7 0.5 1

40 SH 203 T-B 40 NA 2CDS 233 103 R0405 63275 1 0.5 1

B

UBmax

440 V ~60 V ...

UBmax

440 V ~

Selection tables SH 200 T-BMCBs SH 200 series T3000

3/4 ABB

3

Compact Home

C SH 200 T C characteristicFunction: protection and control of the circuits against overloads and short-circuits; protection forresistive and inductive loads with low inrush current.

Applications: buildings, both residential and commercial

Standard: IEC/EN 60898

Icn=3kA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 6 SH 201 T-C 6 2CDS 231 001 R0064 63191 4 0.125 10

8 SH 201 T-C 8 2CDS 231 001 R0084 63193 8 0.125 10

10 SH 201 T-C 10 2CDS 231 001 R0104 63194 5 0.125 10

13 SH 201 T-C 13 2CDS 231 001 R0134 63196 9 0.125 10

16 SH 201 T-C 16 2CDS 231 001 R0164 63198 3 0.125 10

20 SH 201 T-C 20 2CDS 231 001 R0204 63200 3 0.125 10

25 SH 201 T-C 25 2CDS 231 001 R0254 63202 7 0.125 10

32 SH 201 T-C 32 2CDS 231 001 R0324 63204 1 0.125 10

40 SH 201 T-C 40 2CDS 231 001 R0404 63206 5 0.125 10

2 6 SH 202 T-C 6 2CDS 232 001 R0064 63225 6 0.25 5

8 SH 202 T-C 8 2CDS 232 001 R0084 63227 0 0.25 5

10 SH 202 T-C 10 2CDS 232 001 R0104 63228 7 0.25 5

13 SH 202 T-C 13 2CDS 232 001 R0134 63230 0 0.25 5

16 SH 202 T-C 16 2CDS 232 001 R0164 63232 4 0.25 5

20 SH 202 T-C 20 2CDS 232 001 R0204 63234 8 0.25 5

25 SH 202 T-C 25 2CDS 232 001 R0254 63236 2 0.25 5

32 SH 202 T-C 32 2CDS 232 001 R0324 63238 6 0.25 5

40 SH 202 T-C 40 2CDS 232 001 R0404 63240 9 0.25 5

3 6 SH 203 T-C 6 2CDS 233 001 R0064 63242 3 0.375 1

8 SH 203 T-C 8 2CDS 233 001 R0084 63244 7 0.375 1

10 SH 203 T-C 10 2CDS 233 001 R0104 63245 4 0.375 1

13 SH 203 T-C 13 2CDS 233 001 R0134 63247 8 0.375 1

16 SH 203 T-C 16 2CDS 233 001 R0164 63249 2 0.375 1

20 SH 203 T-C 20 2CDS 233 001 R0204 63251 5 0.375 1

25 SH 203 T-C 25 2CDS 233 001 R0254 63253 9 0.375 1

32 SH 203 T-C 32 2CDS 233 001 R0324 63255 3 0.375 1

40 SH 203 T-C 40 2CDS 233 001 R0404 63257 7 0.375 1

4 6 SH 204 T-C 6 2CDS 234 001 R0064 63276 8 0.5 1

8 SH 204 T-C 8 2CDS 234 001 R0084 63278 2 0.5 1

10 SH 204 T-C 10 2CDS 234 001 R0104 63279 9 0.5 1

13 SH 204 T-C 13 2CDS 234 001 R0134 63281 2 0.5 1

16 SH 204 T-C16 2CDS 234 001 R0164 63283 6 0.5 1

20 SH 204 T-C20 2CDS 234 001 R0204 63285 0 0.5 1

25 SH 204 T-C25 2CDS 234 001 R0254 63287 4 0.5 1

32 SH 204 T-C32 2CDS 234 001 R0324 63289 8 0.5 1

40 SH 204 T-C 40 2CDS 234 001 R0404 63291 1 0.5 1

UBmax

440 V ~ 60 V ...

UBmax

440 V~125 V ...①

UBmax

440 V ~

UBmax

440 V ~125 V ...①

① UBmax 125 V ... with 2 poles connected in series

Selection tables SH 200 T-CMCBs SH 200 series T3000

3/5ABB

3

Compact Home

With disconnecting neutral NA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 + NA 6 SH 201 T-C 6 NA 2CDS 231 103 R0064 63208 9 0.25 5

8 SH 201 T-C 8 NA 2CDS 231 103 R0084 63210 2 0.25 5

10 SH 201 T-C 10 NA 2CDS 231 103 R0104 63211 9 0.25 5

13 SH 201 T-C 13 NA 2CDS 231 103 R0134 63213 3 0.25 5

16 SH 201 T-C 16 NA 2CDS 231 103 R0164 63215 7 0.25 5

20 SH 201 T-C 20 NA 2CDS 231 103 R0204 63217 1 0.25 5

25 SH 201 T-C 25 NA 2CDS 231 103 R0254 63219 5 0.25 5

32 SH 201 T-C 32 NA 2CDS 231 103 R0324 63221 8 0.25 5

40 SH 201 T-C 40 NA 2CDS 231 103 R0404 63223 2 0.25 5

3 + NA 6 SH 203 T-C 6 NA 2CDS 233 103 R0064 63259 1 0.5 1

8 SH 203 T-C 8 NA 2CDS 233 103 R0084 63261 4 0.5 1

10 SH 203 T-C 10 NA 2CDS 233 103 R0104 63262 1 0.5 1

13 SH 203 T-C 13 NA 2CDS 233 103 R0134 63264 5 0.5 1

16 SH 203 T-C 16 NA 2CDS 233 103 R0164 63266 9 0.5 1

20 SH 203 T-C 20 NA 2CDS 233 103 R0204 63268 3 0.5 1

25 SH 203 T-C 25 NA 2CDS 233 103 R0254 63270 6 0.5 1

32 SH 203 T-C 32 NA 2CDS 233 103 R0324 63272 0 0.5 1

40 SH 203 T-C 40 NA 2CDS 233 103 R0404 63274 4 0.5 1

C

UBmax

440 V ~60 V ...

UBmax

440 V ~

Selection tables SH 200 T-CMCBs SH 200 series T3000

3/6 ABB

3

Compact Home

BSH 200 L B characteristicFunction: protection and control of the circuits against overloads and short-circuits; protection forpeople and big-length cables in TN and IT systems.

Applications: buildings, both residential and commercial

Standard: IEC/EN 60898

Icn=4.5kA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 6 SH 201 L-B 6 2CDS 241 001 R0065 63294 2 0.125 10

10 SH 201 L-B 10 2CDS 241 001 R0105 63297 3 0.125 10

13 SH 201 L-B 13 2CDS 241 001 R0135 63299 7 0.125 10

16 SH 201 L-B 16 2CDS 241 001 R0165 63301 7 0.125 10

20 SH 201 L-B 20 2CDS 241 001 R0205 63303 1 0.125 10

25 SH 201 L-B 25 2CDS 241 001 R0255 63305 5 0.125 10

32 SH 201 L-B 32 2CDS 241 001 R0325 63307 9 0.125 10

40 SH 201 L-B 40 2CDS 241 001 R0405 63309 3 0.125 10

2 6 SH 202 L-B 6 2CDS 242 001 R0065 63328 4 0.25 5

10 SH 202 L-B 10 2CDS 242 001 R0105 63331 4 0.25 5

13 SH 202 L-B 13 2CDS 242 001 R0135 63333 8 0.25 5

16 SH 202 L-B 16 2CDS 242 001 R0165 63335 2 0.25 5

20 SH 202 L-B 20 2CDS 242 001 R0205 63337 6 0.25 5

25 SH 202 L-B 25 2CDS 242 001 R0255 63339 0 0.25 5

32 SH 202 L-B 32 2CDS 242 001 R0325 63341 3 0.25 5

40 SH 202 L-B 40 2CDS 242 001 R0405 63343 7 0.25 5

3 6 SH 203 L-B 6 2CDS 243 001 R0065 63345 1 0.375 1

10 SH 203 L-B 10 2CDS 243 001 R0105 63348 2 0.375 1

13 SH 203 L-B 13 2CDS 243 001 R0135 63350 5 0.375 1

16 SH 203 L-B 16 2CDS 243 001 R0165 63352 9 0.375 1

20 SH 203 L-B 20 2CDS 243 001 R0205 63354 3 0.375 1

25 SH 203 L-B 25 2CDS 243 001 R0255 63356 7 0.375 1

32 SH 203 L-B 32 2CDS 243 001 R0325 63358 1 0.375 1

40 SH 203 L-B 40 2CDS 243 001 R0405 63360 4 0.375 1

4 6 SH 204 L-B 6 2CDS 244 001 R0065 63379 6 0.5 1

10 SH 204 L-B 10 2CDS 244 001 R0105 63382 6 0.5 1

13 SH 204 L-B 13 2CDS 244 001 R0135 63384 0 0.5 1

16 SH 204 L-B 16 2CDS 244 001 R0165 63386 4 0.5 1

20 SH 204 L-B 20 2CDS 244 001 R0205 63388 8 0.5 1

25 SH 204 L-B 25 2CDS 244 001 R0255 63390 1 0.5 1

32 SH 204 L-B 32 2CDS 244 001 R0325 63392 5 0.5 1

40 SH 204 L-B 40 2CDS 244 001 R0405 63394 9 0.5 1

UBmax

440 V ~60 V ...

UBmax

440 V ~125 V ...①

UBmax

440 V ~

UBmax

440 V ~125 V ...①

① UBmax 125 V ... with 2 poles connected in series

Selection tables SH 200 L-BMCBs SH 200 series L4500

3/7ABB

3

Compact Home

With disconnecting neutral NA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 + NA 6 SH 201 L-B 6 NA 2CDS 241 103 R0065 63311 6 0.25 5

10 SH 201 L-B 10 NA 2CDS 241 103 R0105 63314 7 0.25 5

13 SH 201 L-B 13 NA 2CDS 241 103 R0135 63316 1 0.25 5

16 SH 201 L-B 16 NA 2CDS 241 103 R0165 63318 5 0.25 5

20 SH 201 L-B 20 NA 2CDS 241 103 R0205 63320 8 0.25 5

25 SH 201 L-B 25 NA 2CDS 241 103 R0255 63322 2 0.25 5

32 SH 201 L-B 32 NA 2CDS 241 103 R0325 63324 6 0.25 5

40 SH 201 L-B 40 NA 2CDS 241 103 R0405 63326 0 0.25 5

3 + NA 6 SH 203 L-B 6 NA 2CDS 243 103 R0065 63362 8 0.5 1

10 SH 203 L-B 10 NA 2CDS 243 103 R0105 63365 9 0.5 1

13 SH 203 L-B 13 NA 2CDS 243 103 R0135 63367 3 0.5 1

16 SH 203 L-B 16 NA 2CDS 243 103 R0165 63369 7 0.5 1

20 SH 203 L-B 20 NA 2CDS 243 103 R0205 63371 0 0.5 1

25 SH 203 L-B 25 NA 2CDS 243 103 R0255 63373 4 0.5 1

32 SH 203 L-B 32 NA 2CDS 243 103 R0325 63375 8 0.5 1

40 SH 203 L-B 40 NA 2CDS 243 103 R0405 63377 2 0.5 1

B

UBmax

440 V ~60 V ...

UBmax

440 V ~

Selection tables SH 200 L-BMCBs SH 200 series L4500

3/8 ABB

3

Compact Home

C SH 200 L C characteristicFunction: protection and control of the circuits against overloads and short-circuits; protection forresistive and inductive loads with low inrush current.

Applications: buildings, both residential and commercial

Standard: IEC/EN 60898

Icn=4.5kA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 6 SH 201 L-C 6 2CDS 241 001 R0064 63293 5 0.125 10

8 SH 201 L-C 8 2CDS 241 001 R0084 63295 9 0.125 10

10 SH 201 L-C 10 2CDS 241 001 R0104 63296 6 0.125 10

13 SH 201 L-C 13 2CDS 241 001 R0134 63298 0 0.125 10

16 SH 201 L-C 16 2CDS 241 001 R0164 63300 0 0.125 10

20 SH 201 L-C 20 2CDS 241 001 R0204 63302 4 0.125 10

25 SH 201 L-C 25 2CDS 241 001 R0254 63304 8 0.125 10

32 SH 201 L-C 32 2CDS 241 001 R0324 63306 2 0.125 10

40 SH 201 L-C 40 2CDS 241 001 R0404 63308 6 0.125 10

2 6 SH 202 L-C 6 2CDS 242 001 R0064 63327 7 0.25 5

8 SH 202 L-C 8 2CDS 242 001 R0084 63329 1 0.25 5

10 SH 202 L-C 10 2CDS 242 001 R0104 63330 7 0.25 5

13 SH 202 L-C 13 2CDS 242 001 R0134 63332 1 0.25 5

16 SH 202 L-C 16 2CDS 242 001 R0164 63334 5 0.25 5

20 SH 202 L-C 20 2CDS 242 001 R0204 63336 9 0.25 5

25 SH 202 L-C 25 2CDS 242 001 R0254 63338 3 0.25 5

32 SH 202 L-C 32 2CDS 242 001 R0324 63340 6 0.25 5

40 SH 202 L-C 40 2CDS 242 001 R0404 63342 0 0.25 5

3 6 SH 203 L-C 6 2CDS 243 001 R0064 63344 4 0.375 1

8 SH 203 L-C 8 2CDS 243 001 R0084 63346 8 0.375 1

10 SH 203 L-C 10 2CDS 243 001 R0104 63347 5 0.375 1

13 SH 203 L-C 13 2CDS 243 001 R0134 63349 9 0.375 1

16 SH 203 L-C 16 2CDS 243 001 R0164 63351 2 0.375 1

20 SH 203 L-C 20 2CDS 243 001 R0204 63353 6 0.375 1

25 SH 203 L-C 25 2CDS 243 001 R0254 63355 0 0.375 1

32 SH 203 L-C 32 2CDS 243 001 R0324 63357 4 0.375 1

40 SH 203 L-C 40 2CDS 243 001 R0404 63359 8 0.375 1

4 6 SH 204 L-C 6 2CDS 244 001 R0064 63378 9 0.5 1

8 SH 204 L-C 8 2CDS 244 001 R0084 63380 2 0.5 1

10 SH 204 L-C 10 2CDS 244 001 R0104 63381 9 0.5 1

13 SH 204 L-C 13 2CDS 244 001 R0134 63383 3 0.5 1

16 SH 204 L-C 16 2CDS 244 001 R0164 63385 7 0.5 1

20 SH 204 L-C 20 2CDS 244 001 R0204 63387 1 0.5 1

25 SH 204 L-C 25 2CDS 244 001 R0254 63389 5 0.5 1

32 SH 204 L-C 32 2CDS 244 001 R0324 63391 8 0.5 1

40 SH 204 L-C 40 2CDS 244 001 R0404 63393 2 0.5 1

UBmax

440 V ~60 V ...

UBmax

440 V ~125 V ...①

UBmax

440 V ~

UBmax

440 V ~125 V ...①

① UBmax 125 V ... with 2 poles connected in series

Selection tables SH 200 L-CMCBs SH 200 series L

3/9ABB

3

Compact Home

With disconnecting neutral NA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 + NA 6 SH 201 L-C 6 NA 2CDS 241 103 R0064 63310 9 0.25 5

8 SH 201 L-C 8 NA 2CDS 241 103 R0084 63312 3 0.25 5

10 SH 201 L-C 10 NA 2CDS 241 103 R0104 63313 0 0.25 5

13 SH 201 L-C 13 NA 2CDS 241 103 R0134 63315 4 0.25 5

16 SH 201 L-C 16 NA 2CDS 241 103 R0164 63317 8 0.25 5

20 SH 201 L-C 20 NA 2CDS 241 103 R0204 63319 2 0.25 5

25 SH 201 L-C 25 NA 2CDS 241 103 R0254 63321 5 0.25 5

32 SH 201 L-C 32 NA 2CDS 241 103 R0324 63323 9 0.25 5

40 SH 201 L-C 40 NA 2CDS 241 103 R0404 63325 3 0.25 5

3 + NA 6 SH 203 L-C 6 NA 2CDS 243 103 R0064 63361 1 0.5 1

8 SH 203 L-C 8 NA 2CDS 243 103 R0084 63363 5 0.5 1

10 SH 203 L-C 10 NA 2CDS 243 103 R0104 63364 2 0.5 1

13 SH 203 L-C 13 NA 2CDS 243 103 R0134 63366 6 0.5 1

16 SH 203 L-C 16 NA 2CDS 243 103 R0164 63368 0 0.5 1

20 SH 203 L-C 20 NA 2CDS 243 103 R0204 63370 3 0.5 1

25 SH 203 L-C 25 NA 2CDS 243 103 R0254 63372 7 0.5 1

32 SH 203 L-C 32 NA 2CDS 243 103 R0324 63374 1 0.5 1

40 SH 203 L-C 40 NA 2CDS 243 103 R0404 63376 5 0.5 1

C

UBmax

440 V ~60 V ...

UBmax

440 V ~

Selection tables SH 200 L-CMCBs SH 200 series L4500

3/10 ABB

3

Compact Home

B SH 200 B characteristicFunction: protection and control of the circuits against overloads and short-circuits; protection forpeople and big-length cables in TN and IT systems.

Applications: buildings, both residential and commercial

Standard: IEC/EN 60898

Icn=6kA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 6 SH 201-B 6 2CDS 211 001 R0065 63058 0 0.125 10

10 SH 201-B 10 2CDS 211 001 R0105 63061 0 0.125 10

13 SH 201-B 13 2CDS 211 001 R0135 63063 4 0.125 10

16 SH 201-B 16 2CDS 211 001 R0165 63065 8 0.125 10

20 SH 201-B 20 2CDS 211 001 R0205 63067 2 0.125 10

25 SH 201-B 25 2CDS 211 001 R0255 63069 6 0.125 10

32 SH 201-B 32 2CDS 211 001 R0325 63071 9 0.125 10

40 SH 201-B 40 2CDS 211 001 R0405 63073 3 0.125 10

2 6 SH 202-B 6 2CDS 212 001 R0065 63104 4 0.25 5

10 SH 202-B 10 2CDS 212 001 R0105 63107 5 0.25 5

13 SH 202-B 13 2CDS 212 001 R0135 63109 9 0,25 5

16 SH 202-B 16 2CDS 212 001 R0165 63111 2 0.25 5

20 SH 202-B 20 2CDS 212 001 R0205 63113 6 0.25 5

25 SH 202-B 25 2CDS 212 001 R0255 63115 0 0.25 5

32 SH 202-B 32 2CDS 212 001 R0325 63117 4 0.25 5

40 SH 202-B 40 2CDS 212 001 R0405 63119 8 0.25 5

3 6 SH 203-B 6 2CDS 213 001 R0065 63127 3 0.375 1

10 SH 203-B 10 2CDS 213 001 R0105 63130 3 0.375 1

13 SH 203-B 13 2CDS 213 001 R0135 63132 7 0.375 1

16 SH 203-B 16 2CDS 213 001 R0165 63134 1 0.375 1

20 SH 203-B 20 2CDS 213 001 R0205 63136 5 0.375 1

25 SH 203-B 25 2CDS 213 001 R0255 63138 9 0.375 1

32 SH 203-B 32 2CDS 213 001 R0325 63140 2 0.375 1

40 SH 203-B 40 2CDS 213 001 R0405 63142 6 0.375 1

4 6 SH 204-B 6 2CDS 214 001 R0065 63173 0 0.5 1

10 SH 204-B 10 2CDS 214 001 R0105 63176 1 0.5 1

13 SH 204-B 13 2CDS 214 001 R0135 63178 5 0.5 1

16 SH 204-B 16 2CDS 214 001 R0165 63180 8 0.5 1

20 SH 204-B 20 2CDS 214 001 R0205 63182 2 0.5 1

25 SH 204-B 25 2CDS 214 001 R0255 63184 6 0.5 1

32 SH 204-B 32 2CDS 214 001 R0325 63186 0 0.5 1

40 SH 204-B 40 2CDS 214 001 R0405 63188 4 0.5 1

UBmax

440 V ~60 V ...

UBmax

440 V ~125 V ...①

UBmax

440 V ~

UBmax

440 V ~125 V ...①

① UBmax 125 V ... with 2 poles connected in series

Selection tables SH 200 BMCBs SH 200 series6000

3/11ABB

3

Compact Home

With disconnecting neutral NA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 + NA 6 SH 201-B 6 NA 2CDS 211 103 R0065 63081 8 0.25 5

10 SH 201-B 10 NA 2CDS 211 103 R0105 63084 9 0.25 5

13 SH 201-B 13 NA 2CDS 211 103 R0135 63086 3 0.25 5

16 SH 201-B 16 NA 2CDS 211 103 R0165 63088 7 0.25 5

20 SH 201-B 20 NA 2CDS 211 103 R0205 63090 0 0.25 5

25 SH 201-B 25 NA 2CDS 211 103 R0255 63092 4 0.25 5

32 SH 201-B 32 NA 2CDS 211 103 R0325 63094 8 0.25 5

40 SH 201-B 40 NA 2CDS 211 103 R0405 63096 2 0.25 5

3 + NA 6 SH 203-B 6 NA 2CDS 213 103 R0065 63150 1 0.5 1

10 SH 203-B 10 NA 2CDS 213 103 R0105 63153 2 0.5 1

13 SH 203-B 13 NA 2CDS 213 103 R0135 63155 6 0.5 1

16 SH 203-B 16 NA 2CDS 213 103 R0165 63157 0 0.5 1

20 SH 203-B 20 NA 2CDS 213 103 R0205 63159 4 0.5 1

25 SH 203-B 25 NA 2CDS 213 103 R0255 63161 7 0.5 1

32 SH 203-B 32 NA 2CDS 213 103 R0325 63163 1 0.5 1

40 SH 203-B 40 NA 2CDS 213 103 R0405 63165 5 0.5 1

B

UBmax

440 V ~60 V ...

UBmax

440 V ~

Selection tables SH 200 BMCBs SH 200 series6000

3/12 ABB

3

Compact Home

CSH 200 C characteristicFunction: protection and control of the circuits against overloads and short-circuits; protection forresistive and inductive loads with low inrush current.

Applications: buildings, both residential and commercial

Standard: IEC/EN 60898

Icn=6kA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 6 SH 201-C 6 2CDS 211 001 R0064 63057 3 0.125 10

8 SH 201-C 8 2CDS 211 001 R0084 63059 7 0.125 10

10 SH 201-C 10 2CDS 211 001 R0104 63060 3 0.125 10

13 SH 201-C 13 2CDS 211 001 R0134 63062 7 0.125 10

16 SH 201-C 16 2CDS 211 001 R0164 63064 1 0.125 10

20 SH 201-C 20 2CDS 211 001 R0204 63066 5 0.125 10

25 SH 201-C 25 2CDS 211 001 R0254 63068 9 0.125 10

32 SH 201-C 32 2CDS 211 001 R0324 63070 2 0.125 10

40 SH 201-C 40 2CDS 211 001 R0404 63072 6 0.125 10

2 6 SH 202-C 6 2CDS 212 001 R0064 63103 7 0.25 5

8 SH 202-C 8 2CDS 212 001 R0084 63105 1 0.25 5

10 SH 202-C 10 2CDS 212 001 R0104 63106 8 0.25 5

13 SH 202-C 13 2CDS 212 001 R0134 63108 2 0.25 5

16 SH 202-C 16 2CDS 212 001 R0164 63110 5 0.25 5

20 SH 202-C 20 2CDS 212 001 R0204 63112 9 0.25 5

25 SH 202-C 25 2CDS 212 001 R0254 63114 3 0.25 5

32 SH 202-C 32 2CDS 212 001 R0324 63116 7 0.25 5

40 SH 202-C 40 2CDS 212 001 R0404 63118 1 0.25 5

3 6 SH 203-C 6 2CDS 213 001 R0064 63126 6 0.375 1

8 SH 203-C 8 2CDS 213 001 R0084 63128 0 0.375 1

10 SH 203-C 10 2CDS 213 001 R0104 63129 7 0.375 1

13 SH 203-C 13 2CDS 213 001 R0134 63131 0 0.375 1

16 SH 203-C 16 2CDS 213 001 R0164 63133 4 0.375 1

20 SH 203-C 20 2CDS 213 001 R0204 63135 8 0.375 1

25 SH 203-C 25 2CDS 213 001 R0254 63137 2 0.375 1

32 SH 203-C 32 2CDS 213 001 R0324 63139 6 0.375 1

40 SH 203-C 40 2CDS 213 001 R0404 63141 9 0.375 1

4 6 SH 204-C 6 2CDS 214 001 R0064 63172 3 0.5 1

8 SH 204-C 8 2CDS 214 001 R0084 63174 7 0.5 1

10 SH 204-C 10 2CDS 214 001 R0104 63175 4 0.5 1

13 SH 204-C 13 2CDS 214 001 R0134 63177 8 0.5 1

16 SH 204-C 16 2CDS 214 001 R0164 63179 2 0.5 1

20 SH 204-C 20 2CDS 214 001 R0204 63181 5 0.5 1

25 SH 204-C 25 2CDS 214 001 R0254 63183 9 0.5 1

32 SH 204-C 32 2CDS 214 001 R0324 63185 3 0.5 1

40 SH 204-C 40 2CDS 214 001 R0404 63187 7 0.5 1

UBmax

440 V ~60 V ...

UBmax

440 V ~125 V ...①

UBmax

440 V ~

UBmax

440 V ~125 V ...①

① UBmax

125 V ... with 2 poles connected in series

Selection tables SH 200 CMCBs SH 200 series6000

3/13ABB

3

Compact Home

With disconnecting neutral NA

No. of rated order details bbn price price w'ght pack.poles current 40 16779 1 piece group 1 pc. unit

In A type code order code EAN kg pc.

1 + NA 6 SH 201-C 6 NA 2CDS 211 103 R0064 63080 1 0.25 5

8 SH 201-C 8 NA 2CDS 211 103 R0084 63082 5 0.25 5

10 SH 201-C 10 NA 2CDS 211 103 R0104 63083 2 0.25 5

13 SH 201-C 13 NA 2CDS 211 103 R0134 63085 6 0.25 5

16 SH 201-C 16 NA 2CDS 211 103 R0164 63087 0 0.25 5

20 SH 201-C 20 NA 2CDS 211 103 R0204 63089 4 0.25 5

25 SH 201-C 25 NA 2CDS 211 103 R0254 63091 7 0.25 5

32 SH 201-C 32 NA 2CDS 211 103 R0324 63093 1 0.25 5

40 SH 201-C 40 NA 2CDS 211 103 R0404 63095 5 0.25 5

3 + NA 6 SH 203-C 6 NA 2CDS 213 103 R0064 63149 5 0.5 1

8 SH 203-C 8 NA 2CDS 213 103 R0084 63151 8 0.5 1

10 SH 203-C 10 NA 2CDS 213 103 R0104 63152 5 0.5 1

13 SH 203-C 13 NA 2CDS 213 103 R0134 63154 9 0.5 1

16 SH 203-C 16 NA 2CDS 213 103 R0164 63156 3 0.5 1

20 SH 203-C 20 NA 2CDS 213 103 R0204 63158 7 0.5 1

25 SH 203-C 25 NA 2CDS 213 103 R0254 63160 0 0.5 1

32 SH 203-C 32 NA 2CDS 213 103 R0324 63162 4 0.5 1

40 SH 203-C 40 NA 2CDS 213 103 R0404 63164 8 0.5 1

C

UBmax

440 V ~60 V ...

UBmax

440 V ~

Selection tables SH 200 CMCBs SH 200 series6000

3/14 ABB

3

Compact Home

FH 200 AC typeFunction: protection against the effects of sinusoidal alternating earth fault currents; protection againstindirect contacts and additional protection against direct (with I n=30mA) contacts; command andisolation of resistive and inductive circuits.

Application: buildings, both residential and commercial

Standard: IEC/EN 61008

Marking: according to IEC 61008

No. of nominal nominal order details bbn price price w’ght packpoles fault current current 80 12542 1 piece group 1 pc. unit

I n mA In A type code order code EAN kg pc.

2 30 25 FH202 AC-25/0.03 2CSF202006R1250 894209 0.200 1/6

40 FH202 AC-40/0.03 2CSF202006R1400 894308 0.200 1/6

63 FH202 AC-63/0.03 2CSF202006R1630 894407 0.200 1/6

100 25 FH202 AC-25/0.1 2CSF202006R2250 894506 0.200 1/6

40 FH202 AC-40/0.1 2CSF202006R2400 894605 0.200 1/6

63 FH202 AC-63/0.1 2CSF202006R2630 894704 0.200 1/6

300 25 FH202 AC-25/0.3 2CSF202006R3250 894803 0.200 1/6

40 FH202 AC-40/0.3 2CSF202006R3400 894902 0.200 1/6

63 FH202 AC-63/0.3 2CSF202006R3630 895008 0.200 1/6

4 30 25 FH204 AC-25/0.03 2CSF204006R1250 895107 0.350 1/3

40 FH204 AC-40/0.03 2CSF204006R1400 895206 0.350 1/3

63 FH204 AC-63/0.03 2CSF204006R1630 895305 0.350 1/3

100 25 FH204 AC-25/0.1 2CSF204006R2250 895404 0.350 1/3

40 FH204 AC-40/0.1 2CSF204006R2400 895503 0.350 1/3

63 FH204 AC-63/0.1 2CSF204006R2630 895602 0.350 1/3

300 25 FH204 AC-25/0.3 2CSF204006R3250 895701 0.350 1/3

40 FH204 AC-40/0.3 2CSF204006R3400 895800 0.350 1/3

63 FH204 AC-63/0.3 2CSF204006R3630 895909 0.350 1/3

FH 200 A typeFunction: protection against the effects of sinusoidal alternating and direct pulsating earth fault currents;protection against indirect contacts and additional protection against direct (with I n=30mA) contacts;command and isolation of resistive and inductive circuits.

Application: buildings, both residential and commercial

Standard: IEC/EN 61008

Marking: according to EN 61008

No. of nominal nominal order details bbn price price w’ght packpoles fault current current 80 12542 1 piece group 1 pc. unit

I n mA In A type code order code EAN kg pc.

2 30 25 FH202 A-25/0.03 2CSF202102R1250 892403 0.200 1/6

40 FH202 A-40/0.03 2CSF202102R1400 892502 0.200 1/6

63 FH202 A-63/0.03 2CSF202102R1630 892601 0.200 1/6

4 30 25 FH204 A-25/0.03 2CSF204102R1250 892700 0.350 1/3

40 FH204 A-40/0.03 2CSF204102R1400 892809 0.350 1/3

63 FH204 A-63/0.03 2CSF204102R1630 892908 0.350 1/3

Selection tables FH 200 ACRCCBs FH 200 seriesAC and A type

AC

A

3/15ABB

3

Compact Home Selection tables DS9RCBOs series

DS 941 and DS951, B and C characteristicsFunction: protection against both overload and short circuit currents and earth fault currents; additionalprotection against direct contact (thanks to I n=30mA)

Application: buildings, both residential and commercial

No. of type/class nominal nominal order details bbn price price w’ght pack.poles fault current current 80 12542 1 piece group 1 pc. unit

I n mA In A type code order code EAN kg pc.

RCBOs DS 941, Icn= 4.5kA, B characteristics

1P+N AC 30 10 DS 941 B10 30MA AC 16020015 403104 0.200 1/5

16 DS 941 B16 30MA AC 16020023 403203 0.200 1/5

20 DS 941 B20 30MA AC 16020031 403302 0.200 1/5

25 DS 941 B25 30MA AC 16020049 403401 0.200 1/5

RCBOs DS 941, Icn= 4.5kA, C characteristic

1P+N AC 30 10 DS 941 C10-30MA AC 16020403 406600 0.200 1/5

16 DS 941 C16-30MA AC 16020411 406709 0.200 1/5

20 DS 941 C20-30MA AC 16020429 406808 0.200 1/5

25 DS 941 C25-30MA AC 16020437 406907 0.200 1/5

RCBOs DS 951, Icn=6kA, B characteristic

1P+N AC 30 10 DS 951 B10-30MA AC 16021013 410102 0.200 1/5

16 DS 951 B16-30MA AC 16021021 410201 0.200 1/5

20 DS 951 B20-30MA AC 16021039 410300 0.200 1/5

25 DS 951 B25-30MA AC 16021047 410409 0.200 1/5

RCBOs DS 951, Icn= 6kA, C characteristic

1P+N AC 30 10 DS 951 C10-30MA AC 16021369 413608 0.200 1/5

16 DS 951 C16-30MA AC 16021377 413707 0.200 1/5

20 DS 951 C20-30MA AC 16021385 413806 0.200 1/5

25 DS 951 C25-30MA AC 16021393 413905 0.200 1/5Note: for more information about these products and to know the complete range, see the technical catalogue

3/16 ABB

3

Compact Home busbars and end caps E 200

Type Order Code bbn Pins mm2 Phase sequence End caps Pack unit4016779 pcs.EAN

Busbars

PSH 1/12 2CDL110001R1012 651868 12 10 L1-L1… PSH-END 1.1 50

PSH 1/60 2CDL110001R1060 651875 60 10 L1-L1… PSH-END 1.1 20

PSH 2/12 2CDL120001R1012 651882 12 10 L1-L2-L1… incl. 50

PSH 2/58 2CDL120001R1058 651899 58 10 L1-L2-L1… PSH-END 10

PSH 3/12 2CDL130001R1012 651905 12 10 L1-L2-L3-L1… incl. 50

PSH 3/60 2CDL130001R1060 651912 60 10 L1-L2-L3-L1… PSH-END 10

PSH 4/12 2CDL140001R1012 651929 12 10 L1-L2-L3-N-L1… incl. 30

PSH 4/60 2CDL140001R1060 651936 60 10 L1-L2-L3-N-L1… PSH-END 1 50

End caps

PSH-END 1.1 2CDL100011R0011 653169 50

PSH-END 2CDL100001R0002 653176 50

PSH-END 1 2CDL200110R0001 653183 50

3/17ABB

3

Compact Home Selection tables E 200Command devicesE 200 switches

E 200 switchesIsolator for panel installation onto DIN rail acc. to DIN EN 60715Mounting depth: 70mmMounting width: per pole = 17.5mm = 1 moduleColour: grey, RAL 7035Colour of switch lever: red RAL 3000 (r); grey RAL 7000 (g)

Special features– Captive screws with recessed/slotted head, Pozidriv size 2– Integrated lay-on edge for labeling system ILS– Locking device as accessories for unauthorized ON/OFF– Approval: VDE, CCC

No. of rated power order details bbn price price w’ght pack.poles voltage loss 4016779 1 piece group 1 pc. unit

VAC W type code order code EAN kg pc.

Rated current = 16A

1NO 230V 0.15 E201/16g 2CDE281001R1016 645614 0.095 10

1NO 230V 0.15 E201/16r 2CDE281001R0016 645621 0.095 10

2NO 400V 0.30 E202/16g 2CDE282001R1016 645799 0.190 5

2NO 400V 0.30 E202/16r 2CDE282001R0016 645805 0.190 5

3NO 400V 0.45 E203/16g 2CDE283001R1016 645973 0.290 3

3NO 400V 0.45 E 203/16r 2CDE283001R0016 645980 0.290 3

4NO 400V 0.60 E204/16g 2CDE284001R1016 646154 0.390 2

4NO 400V 0.60 E204/16r 2CDE284001R0016 646161 0.390 2

2CD

C 0

51 4

96 F

0003

Technical dataSwitching capacity 1.25 x In; 1.1 x Un; cos = 0..3 acc. to DIN VDE 0632

AC22-A/AC23-A acc. to VDE 0660 part 107,DIN EN 60947-3 resp. IEC 947-3DC21-B for applications up to 60 V DC

Positiv opening acc. to DIN VDE 0113

Short-circuit withstand capacity 24 kAeff in series with NH 00 100 A gL-gG;10 kAeff in series with NH 00 125 A gL-gG

Rated voltage 230/400 V AC; 50/60 Hz

Surge withstand capability Uimp 4 kV acc. to EN 60947-1

Ambient temperature -25 °C to +55 °C

Storage temperature -40 °C to +70 °C

Climatic resistance constant climate 23/83, 40/93, 55/20 [°C/RH]alternating climate 25/95 - 40/93 [°C/RH]

Mounting position optional

Degree of protection IP10 B (with add. task), IP40 in panelboard

Mechanical endurance 20000 switching cycles

Electrical endurance 1000 switching cycles

Min. voltage 12 V AC/DC at 0.1 VA

Min. contact loading 24 V/4 mA

Wire range 2.5 to 50 mm2

Torque 5 Nm

2CD

C 0

52 0

86 F

0005

3/18 ABB

3

Compact Home Selection tables E 200Command devicesE 200 switches

No. of rated power order details bbn price price w’ght pack.poles voltage loss 4016779 1 piece group 1 pc. unit

VAC W type code order code EAN kg pc.

Rated current = 25A

1NO 230V 0.30 E201/25g 2CDE281001R1025 645638 0.095 10

1NO 230V 0.30 E201/25r 2CDE281001R0025 645645 0.095 10

2NO 400V 0.60 E202/25g 2CDE282001R1025 645812 0.190 5

2NO 400V 0.60 E202/25r 2CDE282001R0025 645829 0.190 5

3NO 400V 0.90 E203/25g 2CDE283001R1025 645997 0.290 3

3NO 400V 0.90 E203/25r 2CDE283001R0025 646000 0.290 3

4NO 400V 1.20 E204/25g 2CDE284001R1025 646178 0.390 2

4NO 400V 1.20 E204/25r 2CDE284001R0025 646185 0.390 2

Rated current = 32A

1NO 230V 0.50 E201/32g 2CDE281001R1032 645652 0.095 10

1NO 230 V 0.50 E201/32r 2CDE281001R0032 645669 0.095 10

2NO 400V 0.95 E202/32g 2CDE282001R1032 645836 0.190 5

2NO 400V 0.95 E202/32r 2CDE282001R0032 645843 0.190 5

3NO 400V 1.40 E203/32g 2CDE283001R1032 646017 0.290 3

3NO 400V 1.40 E203/32r 2CDE283001R0032 646024 0.290 3

4NO 400V 1.90 E204/32g 2CDE284001R1032 646192 0.390 2

4NO 400V 1.90 E204/32r 2CDE284001R0032 646208 0.390 2

Rated current = 40A

1NO 230V 0.70 E201/40g 2CDE281001R1040 645676 0.095 10

1NO 230V 0.70 E201/40r 2CDE281001R0040 645683 0.095 10

2NO 400 V 1.40 E202/40g 2CDE282001R1040 645850 0.190 5

2NO 400V 1.40 E202/40r 2CDE282001R0040 645867 0.190 5

3NO 400V 2.10 E203/40g 2CDE283001R1040 646031 0.290 3

3NO 400V 2.10 E203/40r 2CDE283001R0040 646048 0.290 3

4NO 400V 2.80 E204/40g 2CDE284001R1040 646215 0.390 2

4NO 400V 2.80 E204/40r 2CDE284001R0040 646222 0.390 2

Rated current = 45A

1NO 230V 0.90 E201/45g 2CDE281001R1045 645690 0.095 10

1NO 230V 0.90 E201/45r 2CDE281001R0045 645706 0.095 10

2NO 400 V 1.80 E202/45g 2CDE282001R1045 645874 0.190 5

2NO 400V 1.80 E202/45r 2CDE282001R0045 645881 0.190 5

3NO 400V 2.65 E203/45g 2CDE283001R1045 646055 0.290 3

3NO 400V 2.65 E203/45r 2CDE283001R0045 646062 0.290 3

4NO 400V 3.50 E204/45g 2CDE284001R1045 646239 0.390 2

4NO 400V 3.50 E204/45r 2CDE284001R0045 646246 0.390 2

Rated current = 63A

1NO 230V 1.65 E201/63g 2CDE281001R1063 645713 0.095 10

1NO 230V 1.65 E201/63r 2CDE281001R0063 645720 0.095 10

2NO 400 V 3.30 E202/63g 2CDE282001R1063 645898 0.190 5

2NO 400V 3.30 E202/63r 2CDE282001R0063 645904 0.190 5

3NO 400V 4.90 E203/63g 2CDE283001R1063 646079 0.290 3

3NO 400V 4.90 E203/63r 2CDE283001R0063 646086 0.290 3

4NO 400V 6.55 E204/63g 2CDE284001R1063 646253 0.390 2

4NO 400V 6.55 E204/63r 2CDE284001R0063 646260 0.390 2

2CD

C 0

51 0

02 F

0004

3/19ABB

3

Compact Home

No. of rated power order details bbn price price w’ght pack.poles voltage loss 4016779 1 piece group 1 pc. unit

VAC W type code order code EAN kg pc.

Rated current = 80A

1NO 230V 2.60 E201/80g 2CDE281001R1080 645737 0.095 10

1NO 230V 2.60 E201/80r 2CDE281001R0080 645744 0.095 10

2NO 400V 5.15 E202/80g 2CDE282001R1080 645911 0.190 5

2NO 400V 5.15 E202/80r 2CDE282001R0080 645928 0.190 5

3NO 400V 7.75 E203/80g 2CDE283001R1080 646093 0.290 3

3NO 400V 7.75 E 203/80r 2CDE283001R0080 646109 0.290 3

4NO 400V 10.30 E204/80g 2CDE284001R1080 646277 0.390 2

4NO 400V 10.30 E204/80r 2CDE284001R0080 646284 0.390 2

Rated current = 100A

1NO 230V 3.95 E201/100g 2CDE281001R1100 645751 0.095 10

1NO 230 V 3.95 E201/100r 2CDE281001R0100 645738 0.095 10

2NO 400V 7.90 E202/100g 2CDE282001R1100 645935 0.190 5

2NO 400V 7.90 E202/100r 2CDE282001R0100 645942 0.190 5

3NO 400V 11.85 E203/100g 2CDE283001R1100 646116 0.290 3

3NO 400V 11.85 E203/100r 2CDE283001R0100 646123 0.290 3

4NO 400V 15.80 E204/100g 2CDE284001R1100 646291 0.390 2

4NO 400V 15.80 E204/100r 2CDE284001R0100 646307 0.390 2

Rated current = 125A

1NO 230V 6.10 E201/125g 2CDE281001R1125 645775 0.095 10

1NO 230V 6.10 E201/125r 2CDE281001R0125 645782 0.095 10

2NO 400 V 12.20 E202/125g 2CDE282001R1125 645959 0.190 5

2NO 400V 12.20 E202/125r 2CDE282001R0125 645966 0.190 5

3NO 400V 18.30 E203/125g 2CDE283001R1125 646130 0.33 3

3NO 400V 18.30 E203/125r 2CDE283001R0125 645147 0.33 3

4NO 400V 24.35 E204/125g 2CDE284001R1125 645314 0.44 2

4NO 400V 24.35 E204/125r 2CDE284001R0125 645321 0.44 2

Selection tables E 200Command devicesE 200 switches

3/20 ABB

3

Compact Home Selection tables MDRCsMDRCs

MDRCsApplication: buildings, both residential and commercial

Description order details bbn price price w’ght pack.40 16779 1 piece group 1 pc. unit

type code order code EAN kg pc.Staircase lighting time delay switches E232-230 2CDE 110 000 R0501 548243 0.081 1

Description order details bbn price price w’ght pack.80 12542 1 piece group 1 pc. unit

type code order code EAN kg pc.

Load shedding switch LSS1/2 2CSM 112 500 R1311 274407 0.400 1

Failsafe transformer 10-20-30VA TM30/12 2CSM 301 021 R0801 367505 0.450 1rated power, 4-8-12V secondaryrated voltage

Bell transformer input 230V, TS 16/12 2CSM 161 401 R0811 368908 0.300 1output 12V/1.33A

Electro-mechanical modular bell SM1/230 2CSM 131 000 R0821 326304 0.100 12230VAC

Modular buzzer 230VAC RM1/230 2CSM 231 000 R0821 334507 0.100 12

Modular electronic bell 12VAC+10 VA TSM 2CSM 100 000 R0841 007005 0.300 6transformer (two-tones), 2 modules

Bell+buzzer+transformer, TSR 2CSM 100 000 R0831 369608 0.300 12 modules, 24VAC

Daily program timer switch with DTS 1/1 2CSM 111 000 R0601 506607 0.150 1standby battery (3 years), 1 channel

Digital time switches 2CO contact DTS 7/2 2CSM 122 000 R0601 506805 0.150 1complement, 30 memory location

Twilight switches with sensor LS-1 DTS7/2-TWS 2CSM 122 300 R1351 507307 0,350 1with built-in weekly program timerswitch

Installation relays, Uc=230VAC E 259 R10-230 2CSM111000R0401 532804 0.100 10or 115VDC, 1 NO

Installation relays, Uc=230VAC or E 259 R20-230 2CSM112000R0401 533603 0.100 10115VDC, 2 NO

Latching relays, Uc=230VAC or E 251-230 2CSM 111 000 R0201 530305 0.114 12115VDC, 1 NO

Latching relays, Uc=230VAC or E 252-230 2CSM 112 000 R0201 530800 0.116 12115VDC,2NO

Latching relays, Uc=230VAC or E 255-230 2CSM 119 000 R0201 531302 0.121 12115VDC, series

Latching relays, Uc=230VAC or E 256-230 2CSM 114 000 R0201 531708 0.116 12115VDC, 1 NO + 1NC

Description order details bbn price price w’ght pack.80 12542 1 piece group 1 pc. unit

type code order code EAN kg pc.

Surge protection devices, class II, OVR 1N 40 275 P 2CTB 8139 52 R 11 00 506030 0.220 1Imax=40kA, In=15kA, Up=1.2kV,Un=230V, Uc=275V

Surge protection devices, class II, OVR 3N 40 275 P 2CTB 8139 53 R 11 00 506283 0.220 1Imax=40kA, In=15kA, Up=1.2kV,Un=230V, Uc=275VN.B.: for more information about these products and to know the complete range, see the technical catalogue

2CS

C40

0003

B02

02

In consideration of modifications to Standards and materials, the characteristicsand overall dimensions indicated in this catalogue may be considered binding onlyfollowing confirmation by ABB SACE

ABB SACE S.p.A.ABB STOTZ-KONTAKT GmbH