What is a Monitor?

The International Fire Safety Training Association (IFSTA) defines a monitor as follows:

A large caliber water stream usually supplied by siamesing two or more hoselines into a manifold device or by fixed piping that delivers 350 gpm (1400 Lpm) or more.

Page 3: AB Monitors 101

Other Common Terms For Monitors

• Master Stream

• Multiversals

• Deck Gun

• Deck Pipe

• Deluge Gun

• Water Cannon

• Ladder Pipe

• Water Tower

Page 4: AB Monitors 101

What types of monitors are available?

• There are several types of monitors:– Traditional apparatus mounted deck pipes.

• These are permanently installed on the fire apparatus and pre-piped to the fire pump. They can be manually, or electrically operated.

3426 Apollo Deck Pipe

3440 DeckMaster

Stowed Deployed

Page 5: AB Monitors 101

What types of monitors are available? (cont.)

– Multiversal monitors:• Multiversal monitors have a quick mounting system that allow it to

be used directly on the apparatus or quickly removed and mated with a ground base for portable operation using 2 ½” and larger hoselines.

3423 Apollo shown on 2 ½” dual inlet ground

base

Apollo truck mounting flange

3416 Apollo shown on 5” LDH single inlet ground base

Page 6: AB Monitors 101

What types of monitors are available? (cont.)

– Quick Attack monitors:• Monitors that are only used in portable ground based mode.

Usually, these are pre-connected to a hoseline and positioned for quick deployment by one firefighter.

911 Ozzie oscillating monitor3443 Mercury Quick Attack 500 gpm 3446 Mercury Master 1000 gpm

Page 7: AB Monitors 101

What types of monitors are available? (cont.)

– Elevated monitors:• These monitors are mounted on aerial devices (articulating

booms, straight stick ladders, or towers). These can be manual, hard wired electric, or wireless electric devices.

1495 Ladder Pipe3578 Electric StreamMaster

3570 Manual StreamMaster

Page 8: AB Monitors 101

When Would You Use a Monitor?• The size and intensity of a fire are beyond the reach, flow, or

penetration of handlines.• The available water supply is adequate, but personnel are limited.• Sufficient pumping capability is available.• Safety of personnel dictates.• Interior attack can no longer be maintained.

Page 9: AB Monitors 101

What Tactics Are Used With Monitors?

• Monitors can be used with multiple tactics.– Offensive, direct fire attack, i.e. large fully involved structures that are too much for a

handline attack.– Defensive, exterior attack when the situation is too dangerous for an offensive attack.– To backup handlines that are already involved in an exterior attack.– Exposure protection.– Haz-Mat Vapor Mitigation.

Page 10: AB Monitors 101

What to consider when deploying a Monitor

• Proper Positioning:– Even though a monitor can be adjusted up/down/right/left, the

range is usually limited to provide better stability. Once it is in place and operating it must be shut down to be re-positioned. This usually takes more than one person and considerable time (with the exception of quick attack type monitors). The monitor should be placed so it can cover the most surface area of the involved structure.

Page 11: AB Monitors 101

What to consider when deploying a Monitor (cont.)

• Stream Angle:– The angle of the stream should be sufficient so when it enters a

structure the stream will bounce off of the ceiling or other surfaces to make the stream break up into smaller drops providing better extinguishing effectiveness.

Page 12: AB Monitors 101

What to consider when deploying a Monitor (cont).

• Proper Water Supply:– Since a monitor will flow between 350 gpm and 5000 gpm,

having a proper water supply is crucial. Depending on the flow it could be supplied by 2 ½” hoselines up to multiple large diameter hose (LDH).

Page 13: AB Monitors 101

What to consider when deploying a Monitor (cont).

• Personnel Needed:– A ground based portable monitor can take two or more

firefighters to deploy. Once deployed it can usually be operated by one.

– Apparatus mounted monitors can usually be operated by one firefighter

– Some newer small “quick attack” monitors can be deployed and

operated by one firefighter.

Page 14: AB Monitors 101

Summary

You can see that there are many different types of fire monitors. Which one is right for you will depend on your department’s capabilities, tactics, training, and personnel. Akron Brass has a large selection of monitors available to fit wide range of applications.

Page 15: AB Monitors 101

You’ve just completed training on

Akron Brass Monitors 101.

An ISO 9001:2000 Registered Company

For more information or hands on training contact you local Akron Brass district sales manager or customer service at 330-264-5678.

www.akronbrass.com