a3 opal ii & opal eh ts 4.5-3 instruction 8...outlet on the base of cistern. remove inlet valve...

1
PLUMBERS INSTALLATION INSTRUCTIONS For Vitreous China Opal II & Opal II Easy Height Toilet Suite PLEASE READ CAREFULLY BEFORE INSTALLATION ROUGHING IN: The Opal II and Opal II Easy Height pans are universal for both ‘S’ and ‘P’-Trap installations as detailed. The recommended set-out for ‘S’-Trap installations is 140mm from the finished wall with set-out flexibility for existing soil pipe positions ranging from 60mm to 220mm and 25mm sideways adjustment with the Uni-Orbital ® connector supplied, as detailed in Fig. 2. The cistern is only suitable for back inlet connection. It is essential that the cold water connection (1/2” B.S.P. Connection Nipple) be accurately positioned in the wall as detailed in Fig. 1. Allow for recommended bedding height of 10mm from back of pan when applicable. ‘S’- TRAP CONNECTOR FIXING PROCEDURE 1- Mark centre line of the pan on finished wall, as detailed in Fig. 1. This is to be used as a guide when connecting the pan. The centre line can be offset by up to 25mm from the soil pipe, as detailed in Fig. 2. 2- Determine set-out "C" of existing pan connector, as detailed in Fig. 2. Set-out range 60mm - 220mm. Recommended set-out 140mm, as detailed in Fig. 3. For ‘P’ trap installation see Fig. 5. 3- For installation of the Uni-Orbital ® connector, reference must be made to the instructions supplied with the Uni-Orbital ® connector. 4- Prepare for pan fixing method (either bedding or bracket installation) as detailed below. PAN FIXING PROCEDURE Pan bedding: 1- Remove an area of tiles which are within the internal area covered by the foot of the pan to expose the sub floor and provide a bondage key for the bedding mixture. 2- Ensure that the bedding area is clean and free of building material. 3- Locate blanking cap (supplied) into pan fixing holes as detailed in Fig. 6. 4- Prepare bedding sand cement mixture 3:1 to depth of 60mm as detailed in Fig. 3. Note: Do not fill the foot of the pan with bedding mix or include lime or fast drying cement into the mix, these may cause cracking in the foot of the pan. 5- Position and push pan into connector using the marked centre line on the wall as a guide and level pan into bedding mixture, so that the back of the foot of the pan is approximately 10mm above the finished floor as detailed in Fig. 4. It is recommended that wedges are used to support the foot of the pan during the positioning. 6- Locate the cistern on to the pan and check that the cistern is level (side to side) and aligned with the tiling edges. Adjust pan position if necessary. Allow bedding mixture to set for at least 24 hours prior to use. Bracket fixing: 1- Position and push pan into connector using the marked centre line on the wall as a guide and locate the cistern onto the pan, checking that the cistern aligns with the finished wall. Adjust pan position if necessary. Remove the cistern and pan. 2- Locate the D82 Concealed Fixing Brackets into position on centre line of pan 300mm from the finished wall and mark bracket fixing hole centres on finished floor. 3- Drill two holes in the marked positions on the floor. The hole diameter is dependent on the type of fixing system and floor finish. 4- Secure Brackets to finished floor. 5- Ensure that the area around the floor is clean and free from building material. 6- Run a bead of acetic cured silicone sealant at a height of 8mm approximately fully around the foot of the pan which contacts the floor. Use Wedges around the foot base (if required) so that the maximum height of silicone sealant is not greater that 5mm on completion on bedding. 7- Connect pan to connector and locate plastic sleeve into holes in the pan. Fit screw into the bracket and tighten to bed pan to floor while ensuring level, as detailed in Fig. 7. IMPORTANT-DO NOT OVER TIGHTEN, AS THIS MAY CRACK THE PAN FOOT. Snap on plastic cap, as detailed in Fig. 7. 8- Provide support under the pan foot so that it is maintained in the levelled position while the silicone sealant sets. Remove any excess sealant to provide a neat joint between the pan and the floor. Allow at least 24 hours for the bedding sealant to set before use. CISTERN FIXING PROCEDURE Note: The cistern fixes directly to the pan with a robust base fixing system without the need for wall fixing. Back inlet installation: 1- Securely attach the self-adhesive foam seal around the outlet on the base of cistern. Remove inlet valve to gain access to the right hand cistern fixing hole. 2- Position cistern onto pan, and align the cistern fixing holes with the threaded fixing holes located in the cistern platform. 3- Ensure that the back inlet water connection nipple is aligned with the cut out in the back of the cistern. Fit the seals onto the winged fixing bolts. 4- Insert the winged fixing bolts through the cistern fixing holes into the threaded fixing holes located in the pan. Gradually tighten the left and right hand nuts by hand to firmly secure the cistern to pan, as detailed in Fig. 10. 5- Fit cistern stop valve (supplied) to the 1/2” B.S.P. nipple in the wall using approved thread seal, in the downward angled position 45° to the right hand side, as detailed in Fig. 9. 6- Refit the inlet valve into position. 7- Flush the lines before connecting the flexible hose to the cistern stop valve and ensure the hose is not rubbing against the inside of the cistern. 8- Turn on water mains. Open cistern stop valve and check for leaks and operation of mechanisms and valves. Ensure there is no leakage from the cistern into the pan. 9- Adjust water level to the 4.5 litre water level mark inside the cistern by simply turning the float arm screw in a clockwise or anti-clockwise direction as detailed in Fig. 9. 10- Fit cistern lid to check push button operation to complete installation. Issue No: 8 Date of Issue: 04/09/14 Foam seal Winged fixing bolt Seal Cistern Pan Captured nut toggle 10mm bedded position 5mm silicone Level pan when bedding 185 140 mm Recommended Range 60mm - 220mm 220 Pan outlet Fig. 8 Fig. 4 Fig. 5 Fig. 2 Pan Uni-Orbital ® Connector Set-Out Dimension 'C' ‘S’ Trap Bedding Installation ‘P’ Trap Bedding Installation 10 mm bedded position 5mm silicone 185 Fig. 11 Fig. 10 D82 Concealed Fixing Brackets Cap Plastic Sleeve Concealed Fixing Bracket D82 Concealed Bracket Fixing Centre 260 185 220 300 140 recommended (range 60 – 220mm with Uni-Orbital ® connector supplied) Pan outlet Stop Valve and Inlet Valve Detail Increase water level Decrease water level Note: For back inlet installations the working pressure minimum 30 kPa to maximum 1000 kPa flow pressure Finished Wall Pan foot level 100mm PVC DWV soil pipe Recommended set-out dimension 140mm Set-out range 60mm - 220mm “C” Pan seal 220 60 Waste outlet Level pan when bedding Push pan onto Uni-Orbital ® connector Push pan onto connector Fig. 1 Pan Connection 1/2” B.S.P. Nipple Finished wall Important 22mm projection from wall Important: Pan foot level Mark centre line of pan on wall. This can be offset by up to 50mm from the soile pipe, as detailed in Fig. 2. “A” Centre of back inlet connection “B” 110 Dimensions A B Opal II 750 395 Opal II EH 785 435 All measurements are subject to accepted manufacturing tolerances. To ensure accuracy please check actual product dimensions before drilling for installation. The manufacturer reserves the right to change specifications at any time without giving prior notification. This product should be installed by a qualified plumber. Local authority, Water Board, and Building Regulations may apply to the installation of this product, and you should consult the appropriate bodies on these requirements. IMPORTANT TO ACHIEVE A SATISFACTORY 4.5/3L FLUSH PERFORMANCE AND A 4 STAR WATER EFFICIENCY RATING THE CISTERN MUST BE MATCHED WITH A COMPATIBLE CAROMA SMARTFLUSH 4.5/3L TOILET PAN. Fig. 9 Fig. 6 Fig. 7 Fixing Hole Cover Detail for Bedding Installations Bracket Fixing Detail Blanking cap Pan foot Cap Fixing head Pan foot Silicone bedding Threaded stud D82 Concealed Fixing Bracket Plastic sleeve 395 Pan foot level Relieve bed around pan connector Finished Wall 185 260 Fixed installation dimension for all set-outs From pan foot level Important Pan foot level Determine cutting height Preparation For Bedding Fig. 3 140mm Recommended * * Bed height 60mm Uni-Orbital ® connector can be positioned anywhere in shaded area in a 25mm arc 25

Upload: others

Post on 19-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A3 Opal II & Opal EH TS 4.5-3 Instruction 8...outlet on the base of cistern. Remove inlet valve to gain access to the right hand cistern fixing hole. 2-Position cistern onto pan, and

PLUMBERS INSTALLATION INSTRUCTIONSFor Vitreous China Opal II & Opal II Easy Height Toilet Suite

PLEASE READ CAREFULLY BEFORE INSTALLATION

ROUGHING IN:

The Opal II and Opal II Easy Height pans are universal for both ‘S’ and ‘P’-Trap installations as detailed. The recommended set-out for ‘S’-Trap installations is 140mm from the finished wall with set-out flexibility for existing soil pipe positions ranging from 60mm to 220mm and 25mm sideways adjustment with the Uni-Orbital® connector supplied, as detailed in Fig. 2.

The cistern is only suitable for back inlet connection. It is essential that the cold water connection (1/2” B.S.P. Connection Nipple) be accurately positioned in the wall as detailed in Fig. 1. Allow for recommended bedding height of 10mm from back of pan when applicable.

‘S’- TRAP CONNECTOR FIXING PROCEDURE

1- Mark centre line of the pan on finished wall, as detailed in Fig. 1. This is to be used as a guide when connecting the pan. The centre line can be offset by up to 25mm from the soil pipe, as detailed in Fig. 2.

2- Determine set-out "C" of existing pan connector, as detailed in Fig. 2. Set-out range 60mm - 220mm. Recommended set-out 140mm, as detailed in Fig. 3. For ‘P’ trap installation see Fig. 5. 3- For installation of the Uni-Orbital® connector, reference must be made to the instructions supplied with the Uni-Orbital® connector.

4- Prepare for pan fixing method (either bedding or bracket installation) as detailed below.

PAN FIXING PROCEDURE

Pan bedding:

1- Remove an area of tiles which are within the internal area covered by the foot of the pan to expose the sub floor and provide a bondage key for the bedding mixture.

2- Ensure that the bedding area is clean and free of building material.

3- Locate blanking cap (supplied) into pan fixing holes as detailed in Fig. 6.

4- Prepare bedding sand cement mixture 3:1 to depth of 60mm as detailed in Fig. 3. Note: Do not fill the foot of the pan with bedding mix or include lime or fast drying cement into the mix, these may cause cracking in the foot of the pan.

5- Position and push pan into connector using the marked centre line on the wall as a guide and level pan into bedding mixture, so that the back of the foot of the pan is approximately 10mm above the finished floor as detailed in Fig. 4. It is recommended that wedges are used to support the foot of the pan during the positioning.

6- Locate the cistern on to the pan and check that the cistern is level (side to side) and aligned with the tiling edges. Adjust pan position if necessary. Allow bedding mixture to set for at least 24 hours prior to use.

Bracket fixing:

1- Position and push pan into connector using the marked centre line on the wall as a guide and locate the cistern onto the pan, checking that the cistern aligns with the finished wall. Adjust pan position if necessary. Remove the cistern and pan.

2- Locate the D82 Concealed Fixing Brackets into position on centre line of pan 300mm from the finished wall and mark bracket fixing hole centres on finished floor.

3- Drill two holes in the marked positions on the floor. The hole diameter is dependent on the type of fixing system and floor finish.

4- Secure Brackets to finished floor.

5- Ensure that the area around the floor is clean and free from building material.

6- Run a bead of acetic cured silicone sealant at a height of 8mm approximately fully around the foot of the pan which contacts the floor. Use Wedges around the foot base (if required) so that the maximum height of silicone sealant is not greater that 5mm on completion on bedding.

7- Connect pan to connector and locate plastic sleeve into holes in the pan. Fit screw into the bracket and tighten to bed pan to floor while ensuring level, as detailed in Fig. 7. IMPORTANT-DO NOT OVER TIGHTEN, AS THIS MAY CRACK THE PAN FOOT. Snap on plastic cap, as detailed in Fig. 7.

8- Provide support under the pan foot so that it is maintained in the levelled position while the silicone sealant sets. Remove any excess sealant to provide a neat joint between the pan and the floor. Allow at least 24 hours for the bedding sealant to set before use.

CISTERN FIXING PROCEDURE

Note: The cistern fixes directly to the pan with a robust base fixing system without the need for wall fixing.

Back inlet installation:

1- Securely attach the self-adhesive foam seal around the outlet on the base of cistern. Remove inlet valve to gain access to the right hand cistern fixing hole.

2- Position cistern onto pan, and align the cistern fixing holes with the threaded fixing holes located in the cistern platform.

3- Ensure that the back inlet water connection nipple is aligned with the cut out in the back of the cistern. Fit the seals onto the winged fixing bolts.

4- Insert the winged fixing bolts through the cistern fixing holes into the threaded fixing holes located in the pan. Gradually tighten the left and right hand nuts by hand to firmly secure the cistern to pan, as detailed in Fig. 10.

5- Fit cistern stop valve (supplied) to the 1/2” B.S.P. nipple in the wall using approved thread seal, in the downward angled position 45° to the right hand side, as detailed in Fig. 9.

6- Refit the inlet valve into position.

7- Flush the lines before connecting the flexible hose to the cistern stop valve and ensure the hose is not rubbing against the inside of the cistern.

8- Turn on water mains. Open cistern stop valve and check for leaks and operation of mechanisms and valves. Ensure there is no leakage from the cistern into the pan. 9- Adjust water level to the 4.5 litre water level mark inside the cistern by simply turning the float arm screw in a clockwise or anti-clockwise direction as detailed in Fig. 9.

10- Fit cistern lid to check push button operation to complete installation.

Issue No: 8Date of Issue: 04/09/14

Foamseal

Wingedfixing bolt

Seal

Cistern

Pan Capturednut toggle

10m

m b

edde

d po

sitio

n5m

m s

ilicon

e

Level pan when bedding

185

140

mm

Rec

omm

ende

dR

ange

60m

m -

220

mm

220Pan outlet

Fig. 8

Fig. 4 Fig. 5

Fig. 2

Pan Uni-Orbital® Connector Set-Out Dimension 'C'

‘S’ Trap Bedding Installation ‘P’ Trap Bedding Installation

10 m

m b

edde

d po

sitio

n5m

m s

ilicon

e

185

Fig. 11

Fig. 10

D82 Concealed Fixing Brackets

Cap

Plastic Sleeve

ConcealedFixing Bracket

D82 Concealed BracketFixing Centre

260

185

220

300

140 recommended (range 60 – 220mmwith Uni-Orbital® connector supplied)

Pan outlet

Stop Valve and Inlet Valve Detail

Increase water

levelDecrease waterlevel

Note: For back inlet installations the workingpressure minimum 30 kPa to maximum1000 kPa flow pressure

Finished Wall

Pan footlevel

100mm PVC DWVsoil pipe

Recommended set-outdimension 140mm

Set-out range60mm - 220mm

“C”

Pan seal

220

60

Wasteoutlet

Level pan when beddingPush pan onto

Uni-Orbital® connector

Push pan onto connector

Fig. 1

Pan Connection

1/2” B.S.P.Nipple

Finishedwall

Important22mm

projection from wall

Important:Pan foot level

Mark centre line of pan on wall. This can be offset by up to 50mm from the soile pipe, as detailed in Fig. 2.

“A”

Cen

tre

of b

ack

inle

t con

nect

ion

“B”

110

Dimensions A BOpal II 750 395Opal II EH 785 435

All measurements are subject to accepted manufacturing tolerances.To ensure accuracy please check actual product dimensions before drilling for installation.The manufacturer reserves the right to change specifications at any time without giving prior notification.This product should be installed by a qualified plumber. Local authority, Water Board, and Building Regulations may apply to the installation of this product, and you should consult the appropriate bodies on these requirements.

IMPORTANTTO ACHIEVE A SATISFACTORY 4.5/3LFLUSH PERFORMANCE AND A 4 STARWATER EFFICIENCY RATING THE CISTERNMUST BE MATCHED WITH A COMPATIBLECAROMA SMARTFLUSH 4.5/3L TOILET PAN.

Fig. 9

Fig. 6

Fig. 7

Fixing Hole Cover Detail for Bedding Installations

Bracket Fixing Detail

Blankingcap

Pan foot

Cap

Fixinghead

Pan foot

Siliconebedding

Threaded stud

D82 ConcealedFixing Bracket

Plastic sleeve

395

Pan footlevel

Relieve bed around pan connector

Finished Wall

185

260Fixed installation

dimension for all set-outs

From

pan

foot

leve

l

ImportantPan footlevel

Det

erm

ine

cutti

nghe

ight

Preparation For Bedding

Fig. 3 140mm Recommended*

*

Bed height60mm

Uni-Orbital® connectorcan be positionedanywhere in shaded area in a 25mm arc

25