© THIS PLAN IS THE PROPERTY OF GENERATIONHOMES LTD. AND MUST NOT BE COPIED NOR USEDBY ANY THIRD PARTY WITHOUT CONSENT OF COMPANY
PROPOSED RESIDENCE FOR:
ChambersLot 325 DP 465179Crn of Ridgedale Road/ Percy GreensMILLWATER
Rev. Marino
Generation Homes Rodney
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
01 18Page No. No. of Pages
Drawing Issue:
Location Plan
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:500
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
N
LOT 325
PERCY GREENS
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
02 18Page No. No. of Pages
Drawing Issue:
Site Plan
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:100
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
N
5,474
5,033
2,2
29
5,515
2,3
79 6,047
4,976 18,475 5,559
5,8
565
,84
5
11,3
65
27.305
26.500
26.700
19.2 m2
28.0 m2
29.5 m2
50.5 m2
20.4 m2
gas meter
E1 control
Rinnai gas unit
engineer designed timber retaining wallwith safety barrier where over 1.0m high
SS BDY KIT
Silt fence
2:1 excavation breach(shown hatched)
retaining wall to be outsideof easement area of bank(drainage included)
IMPERVIOUS SURFACES654 x 50% = 327m² maxActual Impervious Surfaces =House, including eaves: 263.13m²Driveway, excluding paths <1m wide: 40.02m²Patios: 13.70m²TOTAL IMPERVIOUS = 316.85m2 48.5%COMPLIES UNDER DISTRICT PLAN
25m2 max. under Unitary Plan316.85m2 - 25m2 = 291.85m2 breachDOES NOT COMPLY UNDER THE UNITRARY PLAN
RC Required for:- Breaching max. earthworks excavation- Breaching 1:2 excavation plane (south)- Breaching 6m front yard setbacks- Breaching impervious area under the Unitary Plan 4.14 stormwater management- vehicle crossing within defined road boundary
tap
Vehicle Crossing
tap
SITE COVERAGE654 x 35% = 228.9m² maxActual Site Coverage, including portico &porch but excluding eaves <1m wide:228.9m2 = 35%COMPLIES
CP
DP80Ø
ST
DP80Ø
DP80Ø
DP80Ø
DP80Ø
DP80Ø
DP80Ø
tap
proposedwater meter
CLADDING NOTE:Weatherboard FFL to ground: 225mmWeatherboard FFL to paving: 150mm
Brick rebate level to ground: 100mmBrick rebate level to paving: 25mm
See cladding details
Keystone Compac IV
34kg/ block
sewergrinderpump
SSCONSSCON
TREE
TREE
26.63
SWMH
28.32
SWMH
SWMH
LL25.64
CP
CP
BOB
27.72
PEG 223
PEG 127
77°34'
23.98
37°0
8' 7
.78
359°4
0'
91°11'
25.01
91°11'
4.00
0°0
8'
6.3
2
180°1
0'
6.9
1
175°3
8'
13.2
5
26
26
27
27
28
29
30
31
SWCONN
14. 4
8
FILLCUT
Platform 27.000FFL 27.355
PROPOSED RESIDENCELot 325 DP 461906
654m2
R1.2
R0.5
R0.5
R0.5
26.5
R0.86m front yard
6m
fr ont y
ar d
1m side yard
3m
si d
e y
ar d
ST
CP
R0.2
ST
batter bank 1:2.5 max. grade
DATUM
DP80Ø
DP80Ø
32/33
12
approx. fall 1:6
Channel drain along toe of batterdischarging to a silt trap duringconstruction. Use channel drain to form aclear water diversion for water enteringsite and Warratars and cloth silt fencebehind the silt trap all to ARC guidelines
easem
ent b
oundary
easem
ent boundary
Exposed PebbleConcrete Driveway
Timber Deck
Exposed PebbleConcrete Patio & Path
Notes
Wind zone is high
ContoursContour Interval is 0.5mLevels are in terms of LINZ Datum (SWMH)Contours as per developer's As Built plans: to be checked on site
House LocationLocation of house to be confirmed by client on site with sitesupervisor prior to building setout
Building platform level may vary to make best use of cut & fill
DrainageAll stormwater and sewer drainage to be laid min. 1m away fromhouse
Exposure Zone: Zone CDurability of all fixings to comply with NZBC B2/AS1 and NZS3604 (2011) section 4. Steel connections to be as follows:EXPOSED ie. Open to the weather or < 600mm above groundlevel, and below a 45° line drawn from the lower edge of aprojecting weathertight structure. Material is washed by direct orwind blown rain. Use 304 Stainless Steel. "Fabricated brackets"shall be made from min. 5mm thick mild hot-dip galv. steel.SHELTERED ie. Open to the air but not rain, and above a 45° linedrawn from the lower edge of a projecting weathertight structure.Material is not washed by direct or wind blown rain, but may besubject to wind blown salts. (<7000mm2 per m2 ventilation and >600mm above ground level) Use Hot - Dip Galvanised Steel.CLOSED ie. Dry or internal spaces. Not exposed to rain, groundmoisture or wind blown corrosive salts. (Including Roof Spaceswith Closed Eaves)Nail plates: Continuously coated galv. steelWire dogs & bolts: Hot-dipped galv. steelAll other structural fixings: Mild steel (uncoated, non-galv).
TOPSOIL EXCAVATION346.7m2 x 0.2m = 69.34m3
CUT275m2 x 1.0m x 0.5 = 137.5m3
FILL188m2 x 1.0m x 0.5 = 94m3
TOTAL215.84m3
EARTHWORKS
Max. CUT depth = 1.2mMax. FILL depth = 0.8m
EARTHWORKS VOLUMES
EARTHWORKS DEPTHS
DOES NOT COMPLY
Maximum Cut & Fill Volume = 200m3
28
27.5
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
03 18Page No. No. of Pages
Drawing Issue:
Site Drainage
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:100
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
2,125
SS BDY KIT
Silt fence
tap ta
p
tap over ORG
CP
100Ø
uP
VC
private
S/S
dra
in u
nder
sla
b
100 dia. Novaflowdrain behindRetaining walldraining to silt trap
pre
ssuris
ed S/S
pipe
ST
DP80Ø
DP80Ø
DP80Ø
DP80Ø
DP80Ø
DP80Ø
tap
proposedwater meter
confirm loaction of point withclient signed manufacturers plan
100Ø65Ø
100Ø
65Ø
65Ø
65Ø 65Ø
65Ø
65Ø
65Ø
IP
sewergrinderpump
SWMH
28.32
SWMH
SWMH
LL25.64
CP
CP
SWCONN
TV 65Ø
ST
100 dia. Novaflowdrain behind
Retaining walldraining to silt trap
CP
ST
DATUM
DP80Ø
DP80Ø
conduit in slab for powerand water to island
Channel drain along toe of batterdischarging to a silt trap duringconstruction. Use channel drain to form aclear water diversion for water enteringsite and Warratars and cloth silt fencebehind the silt trap all to ARC guidelines
100Ø SW drain
100Ø SW drain
All Stormwater and Sewer Drainage To BeLaid Minimum 1m Away From House wherepossible
NOTE: Plumbing System is as per NZS/AS 3500 standards
MINIMUM GRADIENT OF DISCHARGE PIPES.1:20 for 32mm diameter pipes and under.1:40 for 65mm diameter pipes and under.1:60 for 100mm diameter pipes and under.
SITE DRAINAGE PLAN 1:100
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
04 18Page No. No. of Pages
Drawing Issue:
Site Landscaping
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:100
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
28.0 m2
29.5 m2
50.5 m2
20.4 m2
Vehicle Crossing
26
26
27
27
28
29
29
30
31
26.5
Exposed PebbleConcrete Driveway
Timber Deck
Exposed PebbleConcrete Patio & Path
Grass Lawn
Clothesline
Kerbing
Mowing Strip
1.8m Timber Fence,Alternate Pailings
Brick Letter Box
Concrete Terrace / Driveway1:25 MIN. fall away from building.
Bark Gardens
LANDSCAPING KEY
Selected Tree
Selected Shrub
28
27.5
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
05 18Page No. No. of Pages
Drawing Issue:
Floor Plan
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:50, 1:1
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
G9
G5
G8 G8
G1
0O
G3
8O
SG
9 O
SG
9G
9
G93SP3
860
760
860
2 / 6
10
410
760
SP
1
760
2 / 5
60
860
2 / 5
10
860 8602 / 510
2 /
610
2 / 8
10
C/S 710
SP
2
G7
G36 G36
G8
7
G93
G9
G93
21
43
s
s
s
90
6,8
90
90
90
1,5
50
70
1,3
80
90
1,2
00
70
1,8
60
90
1,0
90
70
51
070
1,2
60
90
1,8
80
90
3,3
00
90
120 17,415 940
120 1,520 5,180 6,535 4,180 940
90 1,430 90 5,000 90 6,535 90 4,090 730
90 1,430 90 1,110 90 3,800 90 4,635 70 1,850 70 1,100 70 1,190 90 1,640 730
90 2,630 90 3,100 90 700 4,725 90 1,250 70400 90
1,10070
550 70 3,030 90
550 70
90 5,820 90 610 90 4,725 90 2,910 70 550 90 3,010 90
120 6,000 700 4,725 6,810 120
120 18,235 120
90
3,0
00
90
1,1
80
90
1,8
60
90
3,0
00
90
1,8
80
90
3,3
90
12
011
,580
3,2
70
12
014
,850
12
0
12
012
,76
512
0
6,0
00
1,7
00
5,0
65
90
5,8
20
90
1,7
00
5,0
65
90
3,6
80
90
2,0
50
90
1,7
00
3,7
90
90
1,1
85
90 2,630 90 3,800 90
90 1,110 2,520
2,03
6
2,3
51
90
1,0
95
90
70
1,3
80
90
4,2
00
90
3,3
30
90
90
3,6
80
90
65
0
90
90
65
07048
070
1,870 90 1,690
70 3,640
90 920
90 2,440
2,430 LBW
1,4
00
LB
W
84
090
70 600 70 2,970
610 90
XX
YY
gas meter
Bowmac B176
GIB Fyrelinebehind hob
Ceiling Access0.6 x 0.6
Extr
acto
r F
an
du
cte
d t
o e
ave
BEDROOM 2
BEDROOM 1
GARAGE
ST
BATH
WC
ENTRY
LDY
LIVING5.00 x 4.90m
LIN
WR
WR
E/S
KIT
CH
EN
5.82 x 5.82m
4.00 x 3.38m
3.01 x 2.93m
(Area over framing 196.1m2)Area over brick 205.0m2
Porch area 12.05m2
Total Area 217.05m2
BEDROOM 3
BEDROOM 4
WR
3.00 x 3.00m
3.00 x 2.92m
WR
ST
DINING
FAMILY
6.54 x 6.14m
0.9x1.2tiled
0.9x1.2tiled
study nook
Rin
nai 24ltr
Gas H
W U
nit
SCULLERY
therm
al bre
ak
ELEVATION KEY
Extr
acto
r F
an
du
cte
d t
o e
ave
Extractor Fanducted to eave
Fixing type F2/190 x 45
Fixing type E2/90 x 45
Fixing type E2/90 x 45
Fixing type E2/90 x 45
Fix
ing t
ype F
2/1
40 x
45
Fix
ing t
ype E
2/9
0 x
45
Fixing type F2/140 x 45
Fix
ing t
ype F
2/1
40 x
45
tap
tap
DP80Ø
DP80Ø
DP80Ø
DP80Ø
DP80Ø
DP80Ø
TIMBER FRAMING -In accordance withNZS3604:2011All Structural Timber grades to be SG8 unlessnoted otherwise.
2.4m high ext walls: 90x45 H1.2 Boron studs @600mm crs.2.4 high internal load-bearing walls: 90x45 H1.2 Boronstuds @ 600 crs.
Internal non load-bearing walls to be 90 x 45 @ 600 c/cor 70 x 45 @ 450 c/c as indicated on plans.
(Bathroom Wall Framing) Internal wall frames formingthe perimeter and inside the perimeter of bathrooms tobe 90 x 45 H1.2 Boron studs @ 600mm crs
NOTE: H1.2 Bottom Plates NOTE: H1.2 Window &Door Jambs
NOTE: Where external studs @ 600 c/c use 'DanBand' Polypropylene Tape @ 300mm crs to restrainwall underlay from bulging into the cavity
TILE NOTE: Where tiled floor occurs over a slabsawcut. Construct tile control joint using flexiblecoloured sealant.
Expandable foam air seals with backing rods to allexternal doors & windows
STUD TO TOP PLATE FIXING= Fixing Type 'B' unless noted otherwise
LINTEL FIXING= As noted, see page 18 for detail
Bottom Plate Fixing Details:Lumberlok bottom plate fixing anchors@ 900crs max. Complies with clause 7.5.12.2 NZS3604:2011
EXPOSURE ZONE : ZONE CDurability of all fixings to comply with NZBCB2/AS1 and NZS 3604 (2011) section 4. Steelconnections to be as follows:EXPOSED ie. Open to the weather or < 600mmabove ground level, and below a 45° line drawnfrom the lower edge of a projecting weathertightstructure. Material is washed by direct or windblown rain. Use 304 Stainless Steel. "Fabricatedbrackets" shall be made from min. 5mm thickmild hot-dip galv. steel.SHELTERED ie. Open to the air but not rain, andabove a 45° line drawn from the lower edge of aprojecting weathertight structure. Material is notwashed by direct or wind blown rain, but may besubject to wind blown salts. (<7000mm2 per m2ventilation and >600mm above ground level) UseHot - Dip Galvanised Steel.CLOSED ie. Dry or internal spaces. Not exposedto rain, ground moisture or wind blown corrosivesalts. (Including Roof Spaces with Closed Eaves)Nail plates: Continuously coated galv. steelWire dogs & bolts: Hot-dipped galv. steelAll other structural fixings: Mild steel (uncoated,non-galv).
NOTE: Plumbing System is as per AS/NZS 3500
Brick ties 85mm in length to be placed- within 200 around openings- within the top 2 mortar joints- within the bottom 3 mortar joints- in the bottom course where a bond breaker has beenused- elsewhere approx. 5 per m² of wall
NOG NOTE: Additional Noggings must be installed atFrame stage for Towel rails, Wardrobe shelving,Shelves, Gas Units & bottles etc. An additional row ofnogs are to be installed @ 1750mm above FFL in theKitchen for the wall mounted cabinets only. ReferKitchen plan
FLOOR PLAN NOTES:
Smoke alarm installed in accordance with F7/AS1
WIND ZONE IS HIGH
DS = Double under stud
90mm thick un-insulated wall.
90mm thick R2.2 insulated wall.
70mm thick un-insulated wall.
KEY:
INSULATION
Glazing is <30% of wall area therefore schedule method used.
Req. Achieved ROOF: Use R3.2 Batts R2.9 R3.1WALLS: Use R2.2 Batts R1.9 R1.9FLOOR: Use Ribraft slab R1.3 2.74 GLAZING:All Dbl R0.26SKYLIGHTS: NA
B2- GS1-N/1.05
A1- GS1-N1/0.6
B4- GS1-N/0.7
D1- GS1-1/1.2
D3- GS1-N/1.3
E1- GS1-N/2.15
E2- GS1-N/2.1
M1-
BL1-H
/0.6
M4-
GS
1-N
/1.2
N1-
GS
1-N
/0.8
N4-
GS
1-N
/1.8
O1-
GS
1-N
/2.2
5
O3-
GS
1-N
/0.9
P1-
GS
1-N
/0.8
P2-G
S1-N
/0.8
P3-
EP
1/0
.65
Fix
ing type F
2/1
90 x
45
Fix
ing type G
2/1
90 x
45
Fix
ing t
ype F
2/1
40 x
45
Fixing type F2/90 x 45
Fixing type H2/290 x 45
2815
2014
2114
3015
1013
3616
3716
3816
3715
3916
tap
A
B
C
E
M N O P
HTR
HT
R
900 vanity
900 vanity
16
75x7
60
Fixing type E2/90 x 45
Fix
ing t
ype E
2/9
0 x
45
1714
B3- GS1-N/0.5
C1- GS1-N/3.6
D
M2-
BL1-H
/0.6
Fixing type E2/90 x 45
M3-
GS
1-N
/1.2
N3-
GS
1-N
/2.1
O2-
GS
1-N
/2.2
cantile
vere
d t
russes
gable truss lintel
ORG
2100x4800 g
ara
ge d
oor
13a13
Fix
ing t
ype F
2/1
40 x
45
Fix
ing type F
2/1
40 x
45
2.7m recessed ceiling(coved trusses)
gashob
FFL 27.355
A2- GS1-N1/1.55
B1- GS1-N/1.05
D2- GS1-N/0.6
D4- GS1-N/1.65
N2-
GS
1-N
/1.2
5
P3-G
S1-N
/0.7
5P
4-G
S1-N
/0.7
P5-G
S1-N
/0.6
P6-G
S1-N
/0.6
DP80Ø
DP80Ø
L1: 230 PFC precamber 5mm
L2:
Fix
ing type G
2/2
40x45 H
yspan
L4:
230 P
FC
pre
cam
ber
10m
m
Fixing type F2/190 x 45
Fixing type F2/190 x 45
Fix
ing type E
2/9
0 x
45
Fix
ing type E
2/9
0 x
45
gable
tr u
ss lin
tel
DS
DS
DS
DS
DS
DS
DS1113
13b13
1914 16
14
3916
40a16
4016
40a16
4016
2/90x45 at 400c/c studs below gable
dataswitchboardmeterbox
HT
R
L3:
Fix
ing type G
2/1
90x45
2815
4217
4417
860
860
PB4- GS1-N/0.7
refer to client signedmanufacturer's plan
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
06 18Page No. No. of Pages
Drawing Issue:
Foundation Plan
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:50, 1:1
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
6,240 700 4,485 7,050
120 5,180 6,415 120 4,180 120
15
,09
0
21,277
120 6,000 120 580 120 4,485 120 6,810 120
23,3
23
120
11,4
60
120
3,2
70
120
5,420 6,295 5,180
120
6,0
00
120
1,4
60
120
5,0
65
120
6,2
40
1,4
60
5,3
05
3,4
20
12
0
1,1
85
12
0
6,2
40
1,4
60
30
05,0
05
2,505
1,2
95
6,240 400 300 11,535
380 310
31
0
55
055
0
12
03,6
50
12
062
012
0
3,7
70
74
0
12
034
04,0
20
46
0
450 2,140 120 1,080 120
1,200
450 621 120 2,602 118
2,721
18,475
16,895
13,0
05
72
04,8
00
gara
ge
do
or
r eb
ate
72
0
5,420
5,8
50
2,2
39
4,9
15
2,365
846
535
2,3
00
5,5
30
90
0
90
01,1
90
1,200 1,970
1,200 1,380
100
1,0
00
2,125
1,093 1,157 1,157 1,093 1,246 1,308 1,308 1,308 1,245
30
04,8
85
3,800 300
120 580 120 4,905
Additional steel:HD12 each rib top 1.5m
long around perimeter
240x45 H3.2 boundary joist toentire deck. Refer to detail 08, sheet 13
SLAB THICKENING
SL
AB
TH
ICK
EN
ING
EXPOSURE ZONE : ZONE CDurability of all fixings to comply with NZBC B2/AS1 and NZS3604 (2011) section 4. Steel connections to be as follows:EXPOSED ie. Open to the weather or < 600mm above groundlevel, and below a 45° line drawn from the lower edge of aprojecting weathertight structure. Material is washed by direct orwind blown rain. Use 304 Stainless Steel. "Fabricated brackets"shall be made from min. 5mm thick mild hot-dip galv. steel.SHELTERED ie. Open to the air but not rain, and above a 45°line drawn from the lower edge of a projecting weathertightstructure. Material is not washed by direct or wind blown rain,but may be subject to wind blown salts. (<7000mm2 per m2ventilation and >600mm above ground level) Use Hot - DipGalvanised Steel.CLOSED ie. Dry or internal spaces. Not exposed to rain, groundmoisture or wind blown corrosive salts. (Including Roof Spaceswith Closed Eaves)Nail plates: Continuously coated galv. steelWire dogs & bolts: Hot-dipped galv. steelAll other structural fixings: Mild steel (uncoated, non-galv).
DRAINAGEPlumbing system as per NZS/AS3500. See SiteDrainage plan for plumbing layout: pipes omitted fromthis plan for clarity
TILE NOTEWhere tiled floor occurs over a slab saw cut, constructthe control joint useing flexible coloured sealant.
EXPANSIVE SOILS:Class M: Moderately Expansive
CONCRETE:25MPa
ENGINEER:Garry Peters: 021 229 662
DAMP PROOF MEMBRANE:Polythene 0.25m
Engineer to Inspectprepared buildingplatform & raft floor slabprior to concrete pour &issue a producerstatement PS-4construction review.
SC
SC
SC
SC
SC
SCS
C
SC
SC
CHECK ALL DIMENSIONSAGAINST FLOOR PLAN,ANY DISCREPANSIES TOBE VERIFIED BYDESIGNER.
0312
0413
0512
FFL 27.355
SC
SC
1013
460x460 brick columns on 600x600x600deep concrete footing with, 195mm high nib,4/HD12 vertical bars & R10 stirrups at 300crs
no rebate
piles: 125x125 H5 sq senton in 400 dia. x 600 deep cone footing
2/90x45 H5 SG8 bearers
140x45 H3.2 SG8 joists @ 450 crs
140x45 H3.2 SG8 joists @ 600 crs
Showerrebate50mm
Showerrebate50mm
no rebate
no
re
ba
te
no
reb
ate
no rebate
no
reb
ate
no rebate
conduit in slab for powerand water to island
0813
0713
0613
stainless steel deck fixing
40a16
4016
4217
4417
NOTE: pods cut downunder shower shower rebate
to maintain concrete thickness
NOTE: pods cut downunder shower shower rebate
to maintain concrete thickness
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
07 18Page No. No. of Pages
Drawing Issue:
Pod Map
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:50
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
1,100
1,1
00
98
5
1,0
15
1,100
1,1
00
1,100
935
1,015
93
5
635
1,1
00
635
1,1
00
305 795
1,1
00
64
545
5
1,100200 900
45
574
036
0
28
51,1
00
4001,10034028
51,1
00
45
5
340 1,100
Pod Layout
1100 x 1100 x 220 thick polystyrene panels100mm wide ribs between200mm wide ribs where saw cuts300mm wide concrete to perimeterSlab thickenings as dimensioned on Foundation Plan
1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1
1 1
1 1
1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1
1 1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
2 2 3
4
4
5
5
5
5
5
5
5
5
5
6 6 6
7 7
8 9 9 10
11
11
11
11
12 13 13 13
14
15
15
15
16
16
16
17 18 18 18 18 19
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
08 18Page No. No. of Pages
Drawing Issue:
Elevations
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:100, 1:124.98
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
G10O G38OS G5 G8x2
SP1 SP2
G36x2 G7 G87 G9x4, G9 OS
G93x2 SP1G93
535
615
1,1
20
1,0
15
2,1
35
715
2,1
35
827827
1,815
655
40
1,4
40
2,1
35
635
715
820
1,3
15
2,1
35
180 860180
1,460
2,1
35
1,800
985
1,1
50
2,1
35
635
715
955
40
1,1
40
2,1
35
1,0581,058
2,115
750
1,3
85
2,1
35
705 705 705
2,115
720
1,4
15
2,1
35
678678
1,515
820
1,3
15
2,1
35
9301,725
2,815
790
40
1,3
05
2,1
35
600 1,200 600
2,400
350
900
885
1,2
50
2,1
35
930 1,725
2,815
790
40
1,3
05
2,1
35
WB WB
WB WB WB/BRICK WB WB
NOTES:- Window Dimensions are for Window Openings (trim size)- All Glazing excluding Garage to be Double Glazed- All joinery polyester powder coated- All glazing to NZS 4223:1985 Parts 1 and 2 and Part 3:1993- All glazing to bathrooms / WC to be obscure- Expandable foam air seals with backing rods to all external doors and windows- H1.2 boron window & door jambs- Safety glass to NZS 4223: 1999 Part 3 as required 0 - denotes windows with obscure glazing S - Denotes windows with safety glazing- all windows fixed into brick unless stated otherwise
WINDOW SCHEDULE 1:100
Metro Metal Tiles
180mm Colorsteel fascia with125 OG gutter with internalbrackets
Sectional ribline automaticgarage door.
Bagged AustralBricks Riverviewrange 70mm brick on 50mm cavity.
Cedar bevelbackweatherboards
Double glazed aluminium joinery
keystone retaining wall deck footing
natural groundline
25°
ELEVATION 1
0913
1213
3m &
45°
(com
plies)
1:2 control (b
reaches)
3115
0212
1714
3m & 45°
(complies)
1:2 control (c
omplies)
4117
+27,355
1 FFL
+27,355
1 FFL
timber retaining wall with safetybarrier were over 1m high
keystone retaining walldeck footing
natural groundline
25°32/33
15
1:2 control (breaches)
3m & 45°
(complies)
ELEVATION 2
3115
2915
3015
2715
2615
2515
2815
+27,355
1 FFL
+27,355
1 FFL
Rinnai Gas Unit
batter bank max. 1:2.5 grade
timber retaining wallwith safety barrierwhere over 1m high
natural groundline
ELEVATION 3
25°
3m & 45°
(complies)
3m &
45°
(com
plies)
1:2 control (breaches)
32/33
15
0112
1414
1514
1614
1814
2314
1:2 control (c
omplies)
+27,355
1 FFL
+27,355
1 FFL
natural groundlinetimber retaining wall
with safety barrierwhere over 1m high
25°
ELEVATION 4
3m &
45°
(com
plies) 32/33
15
4317
+27,355
1 FFL
+27,355
1 FFL
BUILDING ENVELOPE RISK MATRIX
Elevation 1
Risk Factor Risk Severity Risk Score
Wind zone (per NZS 3604) High risk 1
Number of storeys Low risk 0
Roof/wall intersection design Low risk 0
Eaves width Medium risk 1
Envelope complexity Medium risk 1
Deck design Low risk 0
Total Risk Score: 3
BUILDING ENVELOPE RISK MATRIX
Elevation 2
Risk Factor Risk Severity Risk Score
Wind zone (per NZS 3604) High risk 1
Number of storeys Low risk 0
Roof/wall intersection design Low risk 0
Eaves width Medium risk 1
Envelope complexity Medium risk 1
Deck design Low risk 0
Total Risk Score: 3
BUILDING ENVELOPE RISK MATRIX
Elevation 3
Risk Factor Risk Severity Risk Score
Wind zone (per NZS 3604) High risk 1
Number of storeys Low risk 0
Roof/wall intersection design Low risk 0
Eaves width Medium risk 1
Envelope complexity Low risk 0
Deck design Low risk 0
Total Risk Score: 2
BUILDING ENVELOPE RISK MATRIX
Elevation 4
Risk Factor Risk Severity Risk Score
Wind zone (per NZS 3604) High risk 1
Number of storeys Low risk 0
Roof/wall intersection design Low risk 0
Eaves width Medium risk 1
Envelope complexity Low risk 0
Deck design Low risk 0
Total Risk Score: 2
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
09 18Page No. No. of Pages
Drawing Issue:
Roof Plan
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:50
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
600 6,000 1,335 3,490 600 6,810 600
60
011
,46
060
02,7
90
60
0
600 1,930 600 2,590 2,590 600 5,335 600 2,090 2,690 220 60060
05,0
10
67
51,1
65
1,1
65
67
54,0
75
1,2
65
600
4,3
60
1,2
00
91
533
5
3,4
20
60
0
700
12
,66
03,3
90
2,530 3,190 3,190 5,335 2,690 2,690 820
1,010 7,900 3,525 8,010
5,6
10
3,6
80
5,3
40
20,445
14
,63
020,445
16
,05
0
60
01,2
50
5,9
40
6,2
85
Soffit packed down from undersideof truss bottom chord (305mm)
End truss dropped 90mmto support 90 x 45outriggers @ 900 c/c with90 x 45 flying rafters
Additional layer ofbitumus basedbuilding wrap to roofspace side of truss
Soffit packed downfrom undersideof truss bottom chordto soffit level (305mm)
End tru
ss d
ropped 9
0m
mto
support
90 x
45
outr
iggers
@ 9
00 c
/c w
ith
90 x
45 f
lyin
g r
afters
Additio
nal la
yer
of
bitum
us b
ased
build
ing w
rap to r
oof
space s
ide o
f tr
uss
End truss dropped 90mmto support 90 x 45outriggers @ 900 c/c with90 x 45 flying rafters
Additional layer ofbitumus basedbuilding wrap to roofspace side of truss
coved truss to 2.7m ceilingbuilder to box out ceiling as required
Ceiling Access0.6 x 0.6
Ca
nti
leve
r tr
uss
es
25°
Fa
ll
Extr
acto
r F
an
du
cte
d t
o e
ave
25
° F
all
Extr
acto
r F
an
du
cte
d t
o e
ave
Extractor Fanducted to eave
tap
tap
3416
3516
3115
tap
DP80Ø
DP80Ø
DP80Ø
DP80Ø
Note:frame down under gable trusswith 90x45 (290mm) to soffit level90x45 outriggers @ 900crs
2.7m high boxed out ceiling
300mm raised porchwith flat soffit
beam
J1
DH1 H
1
TG1
J1
J1A
J1
B
J2C
R1
J2
R2
R2
A
J1C
J2A
R1
A
J2B
R2A
R2
T1B
J3
D
H2H
2
TG2
J3
J3
A
J3
B
J4C
R3
J4
R2A
R2
J3
C
J4A
R3
A
J4B
R2R
2A
T2
ET1
T3
T3
T3A
GT1
GT2
T4
R4
H3
H4
R5
J5E
H5
H6
TG
3
J5
J5A
J5B
J6
A
R6
J6
R2A
R2
J5C
T5
V1
V2
CT
1
CT
1
CT
1
CT
1
CT
2
CT
2
CT
1
T6
GT3
J7
H7
H8
TG
4
J7A
T7
T8
A
T7
V3
V4
GT4
J8AH
9
H10
J8
V5
T9
T9
A
T9
B
T1
0
ET
2
T1
T1A
T8
CT
1
V6
V7
J5C
J5D
R7R8
V8
W W W W
O
O
O
O
O
X X X X X O
O
O
W
K
O O O O O O
O
O O
O
O
X X X X X
X X X X Z
X
X
X
X
X
X
X
ZX XO
OOOOOOOO
OO
O
X
X
X
Z
Z
X
Steel Strap Roof Brace
Steel Strap Roof BraceSteel Strap Roof Brace
Steel Strap Roof Brace
Steel Strap Roof Brace
Steel Strap Roof Brace
DP80Ø
DP80Ø
DP80Ø
DP80Ø
DP80Ø
LBW
LB
W
ET3
3115
13a13
13b13
1113
NOTES- US of truss 2455mm AFFL- 305mm Soffit drop- All gable end walls to have additional layer of bitumus based building wrap to roof space side of truss- Under no circumstances shall the back of the gutter be cut down- Wind zone is high- Refer to Buildable layouts truss design.
WIND ZONE IS HIGHroof area = 263.12m2
Downpipes:To NZBC E1/AS1 table 580Ø mm PVC DownpipesCalc:263.12m2 / 70 = 3.75 (8 provided, thereforecomplies)
ROOF FRAMING FIXINGSROOF FRAMING FIXINGSROOF FRAMING FIXINGSROOF FRAMING FIXINGSMetro "Shake" Metal Tiles on 50 x 40 battens @ 370crswith 1/90x3.15 gun nail (0.8 kN) connection on roofunderlay supported on wire netting on pre-fabricated timbertrusses @ 900 crs. R3.2 Batts to ceiling.
Note:frame down under gabletrusswith 90x45 (290mm) tosoffit level90x45 ceiling rafters @900crs
25° Fall 25° Fall
25° Fall
25° Fall
25° Fall 25° Fall
Dropper
Dropper
flat soffit @ 2.4m
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
10 18Page No. No. of Pages
Drawing Issue:
Sections
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:50
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
2,4
55
600
600
3,0
00
ENTRY FAMILY/ DININGHALL-WAY
BEDROOM 2
SECTION X0412
3516
3416
25°
25°
0512
SCULLERY
truss design as per manufacturer's plan
+27,3551 FFL
+27,3551 FFL
2,4
55
2,4
55
600
600
Glazing is <30% of wall area therefore schedule method used.
Req. Achieved ROOF: Use R3.2 Batts R2.9 R3.1WALLS: Use R2.2 Batts R1.9 R1.9FLOOR: Use Ribraft slab R1.3 2.74 GLAZING:All Dbl R0.26SKYLIGHTS: NA
INSULATION
WINDOW NOTES:Expandable Foam Air Seals with Backing Rods to all External Doors andWindows.
Lintel Trim Height = 2,135.
FRAMING NOGS:Additional Noggings must be installed at Frame stage for Towel rails,Wardrobe shelving, Shelves, Gas Units & bottles etc. An additional row ofnogs are to be installed @ 1750mm above FFL in the Kitchen for the wallmounted cabinets only. Refer Kitchen plan.
Plumbing System is as per NZS/AS 3500 standard.
Bottom Plate Fixing Details:Complies with clause 7.5.12.2 NZS 3604:2011.Concrete raft Slab: Lumberlok bottom plate fixing anchors @ 900crsmax, or Fortress Hex Head Screw Bolt 12mm x 150mm long @ 900crsmax with 60mm min edge set back.
VENT RANGEHOOD/EXTRACT TO EXTERIOR EAVE OF BUILDINGWITH PROPRIETARY VERMIN-PROOF & WEATHERPROOF GRILLE.
RAFT SLAB85mm 25MPa concrete on 220 deep pods on 50mm sand blinding.
CEILING13 mm Plasterboard on 75 x 35 proprietary metal ceiling battens @ 600 ctrs.Stopped to level 4 paint finish.Fibreglass Batts Insulation R2.2 to house only. (Excludes garage).
FASCIAColoursteel 180mm Fascia with 1/4 round external gutter system and 600mmwide 4.5mm James Hardie Silkline to soffits. Paint finish to uPVC down pipes.
ROOFMetal Tiles on 50 x 50 battens @ 370crs with 1/90x3.15 gun nail (0.55 kN)connection supported on wire mesh on pre-fabricated timber trusses @ 900crs. R3.2 Batts to ceiling.
BEDROOM 1ENSUITEBEDROOM 2BATHWCBEDROOM 3
SECTION Y
1914
25°
truss design as per manufacturer's plan
+27,3551 FFL
+27,3551 FFL
Walls:
70 Series Brick Veneer on 50mm cavity fixed in strict accordance with themanufacturer's specifications, over breather type wall underlay
180 timber bevelback weatherboards on cavity over breather type wallunderlay
WIND ZONE IS HIGH
EXPOSURE ZONE : ZONE CDurability of all fixings to comply with NZBC B2/AS1 and NZS 3604(2011) section 4. Steel connections to be as followed:EXPOSED ie. Open to the weather or < 600mm above ground level.Material is washed by direct or wind blown rain. Use 304 or 316 StainlessSteel.SHELTERED ie. Open to the air but not rain. Material is not washed bydirect or wind blown rain, but may be subject to wind blown salts.(<7000mm2 per m2 ventilation and >600mm above ground level) UseHot - Dip Galvanised Steel.CLOSED ie. Dry or internal spaces. Not exposed to rain, ground moistureor wind blown corrosive salts. (Including Roof Spaces with Closed Eaves)Use standard Mild Steel products.Veneer Ties to be Galv 470 g/m2Brick Lintels to be Galv 600 g/m2
Brick ties 85mm in length to be placed- Refer Brick Spec for size of brick tie to be used.- within 200 around openings- within the top 2 mortar joints- within the bottom 3 mortar joints- in the bottom course where a bond breaker has been used- elsewhere approx. 5 per m² of wall
All Timber grades to be SG8 unless noted otherwise.
NOTE: All gable end walls to have additional layer of bitumus basedbuilding wrap to roof space side of truss
WALL STUDS:In accordance with NZS3604:2011.Single or Upper: 2.4m Exterior Walls to be 90 x 45 H1.2 Boron studs @600mm crsInterior Walls to be 70/90 x 45 H1.2 Boron studs @ 600mm crs(Unless labelled otherwise for load bearing walls on plan)
NOTE: 'Dan Band' Polypropylene Tape @ 300mmcrs to restrain BuildingPaper from bulging into the Brick Veneer Cavity.
TILE NOTE: Where tiled floor occurs over a slab sawcut. Construct tilecontrol joint using flexible coloured sealant.
0212
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
11 18Page No. No. of Pages
Drawing Issue:
Blank Electrical
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:50
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
G9
G5
G8 G8
G1
0O
G3
8O
SG
9 O
SG
9G
9
G93SP3
860
760
860
2 /
610
410
760
SP
1
760
2 / 5
60
860
2 /
510
860 8602 / 510
2 / 6
10
2 / 8
10
C/S 710
SP
2
G7
G36 G36
G8
7
G93
G9
G93
as
bh
ak
PLgb
d
2d
Gas bayonet
Ceiling extractor fan
Exterior power point
Wall switch
PIR sensor
Owners Own Light
Ceiling light - recessed
Gas continious hot water
Ceiling light
2 way wall switch
Pantry light
Door bell
Single socket outlet
Exterior hose tap
Heated towel railhtr
12.5kw heater
Security Alarm sensor
Security Alarm Keypad
Double socket outlet
tv TV ariel outlet
ph Phone jack point
Halogen pendant light
s Smoke alarm
Meter board
ht
Dimmer switch
Wall light
ELECTRICALDimmer switch - 2 way
2
Ceiling light - halogen
860
860
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
12 18Page No. No. of Pages
Drawing Issue:
Details
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:10
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
185mm Ali-Jamb jamb & headliner.(Modify head liner to suit.)
100
100
120
220
85
50
355
300
55
220
85
50
220
85
85
600
2,1
35 L
inte
l T
rim
Heig
ht
125
120
100
2,4
55
50
220
85 20 5
0
305
2,1
35
20
305
305
125
Metrotile
Tile batten
Underlay lapped over battens andfascia at eaves
Metrotile
Tile batten
Underlay lapped overbattens and fascia at eaves
05. PERIMETER FOOTING WITH REBATE 1:10
SE72 mesh
R6 @ 600 c/c
2/HD 12DPM on 50mmthick sand blinding
SE72 mesh
HD 12 each rib DPM on 50mmthick sand blinding
3/HD 12
SE72 mesh
DPM on 50mmthick sand blinding
G.L.
Typical 300 wide x 305 high rib-raft edge beam
Paved 25mm minUnpaved 100mm min.
R6 @ 600 c/c
03. SLAB THICKENING 1:10 04. TYPICAL INTERMEDIATE RIB 1:10
01. BRICK SILL/ REBATE & WINDOW/ EAVE DETAIL 1:10
125 OG gutter with internal brackets on180mm continuous colorsteel fascia.
100mm deep x 120mm widebrick rebate with Flintcote orsimilar.
70 Series brick veneer
James Hardie 4.5mm Silkline soffit liningwith PVC jointers.
Trusstoe cut
G.L.
DPM
soffit d
rop
25°
75mm GIB cove toall living areas &55mm GIB cove toall other areas.
35mm Nail up metalceiling battens with13mm GIB standardceilings.
60mm Single bevelMUF, 60mm singlebevelFJ Pine to allwet areas.
40mm Single bevelMUF to all doors &windows, 40mmsingle bevelFJ Pineto all wet areas.
Min. overhang at closest
point of the tile 50mm
320 high rib-raft edge beamrefer engineers details
Automatic garage dooropening.
20mm step sloping down to50mm below Garage FFL.
70 Series brick veneerbeyond.
02. GARAGE DETAIL 1:10
All cut edges of LOSP timberto be sealed and paintedbefore installation
Paved 25mm minUnpaved 100mm min. FFL
1414
1514
1614
1714
HD 12 each rib top 1.5mlong around perimeter
25°
140x35 ribbon plate.
James Hardie 4.5mmSilkline soffit lining with PVCjointers.
Garg
ae d
oor
trim
Min. overhang at closest
point of the tile 50mm
soffit d
rop
L4: 230PFC with two understudsand one trimmer stud each end
25mm thick timber headcapping to garage door onpacker to suit.
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
13 18Page No. No. of Pages
Drawing Issue:
Details
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:10
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
50
50
50
550
450
75
550
1200
550
410
90
140
190
410
550
450
timber weatherboard
2/90 x 45 H5SG8 bearer
125 H5 dia. sentonpile in 400 sq x 600deep conc footing140 x 45 SG8 H4 tapered stringer
bolted to edge beam with M12 @1.2m c/c. pack off edge beam with
12mm H3.2 packers @ 1.2m c/c
140 x 45 SG8 H3.2 joists hung offstringer and bearers @ 450 c/c withSS joist hangers
Run decking down front of end joist
refer to fixing detail on page 14
damp proof course damp proof course
L1: 230 PFC
Bowmac B176with 2/M12
L2: 2/240x45 Hyspan
top plate
double understud2/90x45
trimmer
ET2 gable truss lintel
2/190 x 45 seated on 90 x 90 post
13a. BEAM TO POST CONNECTIONS 1:10
Galv. steel sheet brace strap with6 x 30mm x 3.15Ø Lumberloknails per end (6.0kN achieved)
Galv. steel sheet brace strap with6 x 30mm x 3.15Ø Lumberloknails per end (6.0kN achieved)
12. GARAGE LINTEL FIXING 1:10
L4:230PFC
350x80x6 Endplate
5mm fillet welding
3x90x45
M12 @ 1000 c/c
Brick ties every thirdcourse alternatearound post
90x90 G8 H5 post onBowmac BS28bracket.
Provide weepholes at the base
550x450 pad1200mm below CGL
4/HD12 vert. barswith 230mm hook
R10 stirrups @ 300 c/c
10. STRUCTURAL COLUMNBRICK VENEER PLANS 1:10
09. STRUCTURAL COLUMNBRICK VENEER SECTION 1:10
90x90 SG8 H4 post.
Bowmac BS28 bracketfixed with M12 bolt
FFL
CGL
Paving level
600x600 footing1200mm below CGLwith 4/H12 vert bars& R10 stirrups @ 300c/c. 75mm cover allround. Typ. 3 places
packers
06. DECK TO SLAB DETAIL 1:10
FFL 27.355
08. DECK EDGE DETAIL 1:1007. DECK TO PILE DETAIL 1:10
FFL 27.355
G.L. G.L.
11. LINTEL 1 & 2 CONNECTION 1:10
ET3 gable truss lintel
Galv. steel sheet brace strap with6 x 30mm x 3.15Ø Lumberloknails per end (6.0kN achieved)
2/90 x 45 seated on 90 x 90 post
13b. BEAM TO POST CONNECTIONS 1:10
Galv. steel sheet brace strap with6 x 30mm x 3.15Ø Lumberloknails per end (6.0kN achieved)
410x310 concrete nibpoured 295mm abovepaving level
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
14 18Page No. No. of Pages
Drawing Issue:
Details
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:5
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
5m
m m
in.
Flexible flashing tape
Malthoid flashing with dripextended 200mm each side ofwindow.
200mm strip of malthoid flashing,the jamb flashings are to overlap
the sill flashing
Flat packers to support unit
15mm min cover to brick.
Flat packers to support Ali-Jambjamb liner at 600mm crs.
15mm min cover to brick.
185mm Ali-Jamb jamb & head liner.
200mm strip of malthoid flashing,the jamb flashings are to overlap
the sill flashing
5m
m M
in.
25
100
100
120
50 70
120
70 50 90
210
Wall underlay
4.5mm Silkline Soffit Lining
Internal lining
Soffit bearer
Brick veneer cladding
3mm ventilation gap
Provide vent holes every thirdperpend of second course fromthe top
14. WINDOW HEAD DETAIL 1:5
Water resistant 'Air Seal'with backing rod toperimeter of trim cavity.
90 x 45 H3.1 Framing withBreather Type Building Paper over
BT Building Paper folded intoopening & fixed to framingusing approved fixings.
Flexible flashing tape
4.5mm Silkline Soffit Lining
Tekton universal building wrapfolded into opening & fixed toframing using approved fixings.
Brick Veneer Sill Flat packers to support unit.
Keep drainagepassage clear
Sill 15 degree min. slopeoverhang 30 - 50 mm
Vent every third perpend
Tekton universal building wrap overframing - support with polyproplyenetape straps @ 300mm crs.
18. DOOR SILL DETAIL 1:5
DPC under liner
Brick Veneer Sill. 5.0° fallaway from building. Weepholes every third perpend
Flat packers to support unit.
NOTE:Sill sealing method for flangeend type drainage systems
5m
m m
in
Keep drainagepassage clear
3x Coats of Flintcote to 80w x 100hBrick veneer recess
Aluminium Support Bar with8 guage screws min. 50mm crslong @ 400crs into Slab
Head seal
10mm Interior GIB wall lining.
R2.2 Wall insulation.
Protecto Wrap Flashing System selfadhesive overlays installed tomanufacture's spect. over timberframing & trimming members full widthof opening wrap - lap 200mm up jamb.
10mm Interior GIB wall lining.
R2.2 Wall insulation.
H3 Treated timber jambs.
H3 Treated timber jambs.
Tile to sill at FFL withaluminium edge.
Line of architrave.
Slab edge.
Water resistant 'Air Seal' with backingrod to perimeter of trim cavity.
Concrete / Paving.
Unprotected Ground.
Line of brick rebate beyond.
20x20 kickout batten
Air seal
Cavity 40mm - 60mm40mm recommended
Flexible sealant toperimeter of hole
Pipe penetration tobe sealed with tapeto building wrap
70mm Monier Brick
Pipe to slope down to theoutside
22. PIPE PENETRATION THROUGHBRICK CLADDING 1:5
16. WINDOW JAMB DETAIL 1:5
Tekton universal building wrapfolded into opening & fixed toframing using approved fixings.
Protecto Wrap Flashing System selfadhesive overlays installed tomanufactures spect. over timberframing & trimming members full widthof opening wrap - lap 200mm up jambs.
200mm minturn-up to
flexible flashing
H3.1 jamb packers
24. TYPICAL WINDOW OPENING FLASHING DETAIL NTS
Flexible sill flashing full widthof opening over wrap
50 mmmin lap
Building wrap turned into openingover framing
23. BRICK SOFFIT DETAIL. 1:5
70 Brick veneer
BT building paper
Insulation
Interior lining
Brick veneer tiesevery 350mm ctrs vert.as per monier spec.
70 Brick veneer
BT building paper
Insulation
Interior lining
Brick veneer tiesevery 350mm ctrs vert.as per monier spec.
Note: Additional stud atinternal corners whenless than 600mm.
17. GARAGE DOOR JAMB DETAIL 1:5
Protecto Wrap Flashing Systemself adhesive overlays installedto manufactures spect. overtimber framing & folded up DPC- lap 200mm up jambs.
Tekton universal building wrapfolded into opening & fixed toframing using approved fixings.
Air seal over continuous backing rod.
70mm Brick Veneer
Flat packers to support unit.
15mm min cover to brick
19. DOOR JAMB DETAIL 1:5
Aluminium Door
Water resistant 'Air Seal'with backing rod toperimeter of trim cavity.
15. WINDOW SILL DETAIL 1:5
150mm Strip 'Super Course',clout fixed over BT building paper
50mm Ventilated Cavity
200mm strip of malthoid flashing,the jamb flashings are to overlap
the sill flashing
20. BRICK EXTERNAL CORNER 1:5
21. BRICK INTERNAL CORNER 1:5
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
15 18Page No. No. of Pages
Drawing Issue:
Details
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:5, 1:20
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
Metrotile
Batten
Underlay
Batten
Standard Barge85mm
.
50 m
in
15
70
30
5
30
0
Cedar bevel back weatherboard,50mm cladding cover to head flashingupstand, 15mm drip edge to cavityclosure
Cavity closure
Wall underlay turned into framingreveal, flexible flashing tape at corners
Wall underlay flap lapped over flashing
Head flashing by joinery manufacturer
with 15° slope and 20mm stop-end to
extend 20mm min beyond outer edge
of jamb, facing or scriber
Aluminium joinery profile
50mm min cladding cover toflashing upstand
Air seal over backing rod
Architrave or grooved liner
cavity batten
Line of timber scriber
Internal lining
7.5mm
Tilting fillet where required for support
Packing and window supportbrackets as required
10mm min cover
Internal lining
Timber scriberextending to undersideof head facing (windowhead)
5mm gap toweatherboard optional
10mm min flangecover to weatherboard
Aluminium joineryprofile
Line of head flashingextending to outeredge of jamb facings
Continuous vertical20mm H1.2 boron jambpacker to end of sill tray
Air seal over backing rod
Architrave or slimlinedetail
cavity batten
7.5mm
Cedar bevelbackweatherboard
Wall underlay turnedinto framing reveals andtaped at corners
Packing and windowsupport brackets as
required
Base board to finish 50mm min below
floor level (and 175mm above finished
ground level or 100mm above paving)
Weatherboard fixed to timber packing
block. Packing to be fixed through
WANZ bar to foundation and to have
castleations to frontConcrete floor slab
Cedar bevel back weatherboard
DPC
Wall underlay
Base board to finish 50mm min below
floor level (and 175mm above finished
ground level or 100mm above paving)
Concrete floor slab
Cavity closer
Cedar base board
225mm from slab surface to natural
ground (150mm to paving)
Cavity batten
Internal lining
Cedar bevel back weatherboard
Wall underlay
Timber 42 x 18mm eaves mould with
weathergroove - fit tight to soffit lining
Soffit lining
Internal lining
Soffit bearer
Timber cavity batten - close off top ofcavity from soffit space
Roof cladding and underlay todesigners specification
Timber transition scriber
100 x 25 uPVC flashing,70mm min. cover
Cedar bevel back weatherboard
Wall underlay
Timber cavity batten
50mm masonryveneer cavity 3mm min gap between
flashing & veneer
Cedar bevel backweatherboard
Timber bead
180mm colorsteel
fascia
Eaves lining
90x45 ceiling joists at 900crs
2/190x45
2/90x45
Malthoid flashing
25. WEATHERBOARD WINDOW HEAD 1:5
5m
m m
in
30. WEATHERBOARD WINDOW JAMB 1:5
26. WEATHERBOARD BASE OF WALL 1:5
27. BASE OF WALL UNDER FULLHEIGHT WINDOW 1:5
29. FLAT SOFFIT DETAIL. Scale 1:5
28. WEATHERBOARD TO BRICKVENEER Scale 1:5
End structural truss
dropped 90mm to support
90 x 45 outriggers @ 900
c/c with 90 x 45 fly rafters
Batten
Outrigger
roofing underlay
supported on wire netting
Flying rafter
Flashing
2455
frame down from gable truss
with 90x45 to soffit height
weatherboard 20mm overhang
2755
frame down from gable truss
with 90x45 to soffit height
ENTRANCE ROOF
LOUNGE PORCH
31. BARGE WITH TIMBER WEATHERBOARD 1:5
400
Scoria backfill H5 pole at 1.2 crs
20MPA concrete100mm slump
50mm RS
33. ENGINEER DESIGNEDRETAINING WALL 1:20
1
20
Retaining Height
Embedment
1
000
100 x 50 Balusters@ 1m ctrs fixed with2 M12 to Retaining wall poles
Ex 50 x 50 Balusterswith max 100 mm gaps
150 x 50 Rail
Required w
here
fall
is 1
m o
r gre
ate
rH
eig
ht =
1.0
m o
r gre
ate
r
32. TYPICAL RETAINING WALL WITHPERMANENT SAFETY BARRIER 1:20
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
16 18Page No. No. of Pages
Drawing Issue:
Details
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:5, 1:2, 1:20
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
150
145
50m
m m
in
50
50mm min
250mm min. gutter width*
50
180
20
Fixing through upstand
Tile battens
Barrel or Vee ridge
Min. cover of ridgetile 35mm at anypoint
Valley boards 25x150mm
Valley tray
Metrotile
Underlay separating valleyboard and valley tray
Tile batten
Valley tile turned down
into valley tray
25mm min. thick valley boards
cut and supported between
rafters/truss. Top of valley
boards flush with top of
rafters/truss
roofing underlay supported on wire netting
roofing underlaysupported on wire netting
Note:*Minimum width of valley tray may reduce to 160mm
providing roof catchment area is 16m² or less
34. METROTILE VALLEY GUTTER DETAIL 1:5
35. METROTILE ROOF RIDGE DETAIL 1:5
50
100
50
TILE NOTES:Where tiled floor occurs over a slab saw cut. Construct tilecontrol joint using flexible coloured sealant.Ardex Superflex waterproofing membrane under floor tilesin wet areas and in tiled shower cubical floor & walls.Ardex Superflex WPS to bath & basin surround that aretiled in wet areas.
Tile adhesive
2mm. Flexible Grout
10mm. GIB Aqualine
shower tiles fall to wasteFloor tile
Line of Shower Manglass shower screen
CONCRETE FLOORCONCRETE FLOOR
Timber framed wall.
40. TILED SHOWER BASE DETAIL 1:2
50mm Rebate inconcrete floor
50mm Rebate inconcrete slab.
Selected screed toform fall to waste.
NOTE: Ensure slab depth to showeris maintained under shower recess.(i.e. recess pods or solid fill.)
NOTE: Ensure slab depth to showeris maintained under shower recess.(i.e. recess pods or solid fill.)
25
25
Tile adhesive
2mm. Flexible Grout
10mm. GIB Aqualine
Floor tile
CONCRETE FLOORCONCRETE FLOOR
Ardex Superflex internal membrane
Timber framed wall.
25x5mm Saw Cutin concrete slab.
39a. TILED FLOOR / SAW CUT DETAILTO BATH & ENSUITE 1:2
Ardex Superflex waterproofing in shower
Taped corner joint (or silicone)
Chrome tile capping withgood silicone bead to wall
Fall floor to FWG.
40a. TILED SHOWER BASE DETAIL 1:2
Ardex Superflexinternal membrane
Ardex Superflexinternal membrane.
Ardex Superflex waterproofingin shower
CONCRETE FLOOR
38. TILED FLOOR / WALLJUNCTION TO WC1:2
25x5mm Saw Cut in concrete slab.
Timber framed wall.
Tile adhesive
2mm. Flexible Grout
10mm. GIB Aqualine
Floor tile
CONCRETE FLOOR
Taped corner joint (or silicone)
Chrome tile capping withgood silicone bead to wall
39. TILED FLOOR / WALL JUNCTION TO BATH& ENSUITE 1:2
38a. TILED FLOOR / SAW CUTDETAIL TO WC 1:2
10
465
10
200
70x35framedup shelf
45 x 45 timber blocktrimmed to suit 2º fall
6.5mm Villaboard on70x35 timber framing
area to be fully sealed
jack studs
BATH
2º fall
ceramic tiles with specifiedadhesive and grouting
10mm Aqualine fixedonto wall frameNOT TO SCALE
36. TILED SHELF TOBATH DETAIL 1:20
Blocking to bath to suit
Area to be fully sealed
Ardex Superflex WPS to2.0m high above FFL
from top of bath rim onwater resistant surface
10mm GIBAqualine fixed
onto wall frame.
BATH
37. TILE OVER BATHSECTION 1:20
Ardex Superflex WPS to 2.0mhigh above FFL from top of bathrim on water resistant surface
TILE NOTES:Where tiled floor occurs over a slab saw cut. Construct tilecontrol joint using flexible coloured sealant.Ardex Superflex waterproofing membrane under floor tilesin wet areas and in tiled shower cubical floor & walls.Ardex Superflex WPS to bath surround and walls 2.0mAFFL in wet areas.
ceramic tiles withspecified adhesive and
grouting
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
17 18Page No. No. of Pages
Drawing Issue:
Details
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:10
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY
460
450
1200
460
460
75
320
320
460
450
1200
450
310
75
170
450
450
310
310
Provide weepholes at the base
550x450 pad1200mm below CGL
R10 stirrups @ 300 c/c
Brick ties every thirdcourse alternatearound post
90x90 G8 H5 post onBowmac BS28bracket.
4/HD12 vert. barswith 230mm hook
42. STRUCTURAL COLUMNBRICK VENEER PLANS 1:10
41. STRUCTURAL COLUMNBRICK VENEER SECTION 1:10
FFL
CGL
Bowmac BS28 bracketfixed with M12 bolt
90x90 SG8 H4 post.
460x460 footing1200mm below CGLwith 4/H12 vert bars& R10 stirrups @ 300c/c. 75mm cover allround. Typ. 3 places
Paving level
packers
410x310 concrete nibpoured 295mm abovepaving level
Provide weepholes at the base
550x450 pad1200mm below CGL
R10 stirrups @ 300 c/c
Brick ties every thirdcourse alternatearound post
90x90 G8 H5 post onBowmac BS28bracket.
4/HD12 vert. barswith 230mm hook
44. STRUCTURAL COLUMNBRICK VENEER PLANS 1:10
43. STRUCTURAL COLUMNBRICK VENEER SECTION 1:10
FFL
CGL
Bowmac BS28 bracketfixed with M12 bolt
90x90 SG8 H4 post.
450x450 footing1200mm below CGLwith 4/H12 vert bars& R10 stirrups @ 300c/c. 75mm cover allround. Typ. 3 places
Paving level
packers
410x310 concrete nibpoured 295mm abovepaving level
CHAMBERS
Lot 325 DP 46517957 Ridgedale RdMILLWATER
Building consent
18 18Page No. No. of Pages
Drawing Issue:
Connections
Johanna Hinton
@ A2
Date:
Scale:
Design:
Drawn by:
12/12/2013
1:1.12, 1:1.15, 1:100, 1:1.32, 1:1.25
NOTES:1) All dimensions and underground service locations to be checked prior to construction.2) Do not scale from drawings. If in doubtplease ask the designer.3) Construction and method of construction tobe in accordance with the specification, the NZBCand with local bylaws.4) These drawings are subject to copyright andremain the property of Generation Homes Ltd.
Project:
Revisions:
T 09 424 0088
A 1B Polarity Rise, Silverdale 0944
AUCKLAND
Long Term Design LTD
GENERATION HOMES
Rev. Marino
© THIS PLAN IS THE PROPERTYOF GENERATION HOMES LTD.AND MUST NOT BE COPIED NORUSED BY ANY THIRD PARTYWITHOUT CONSENT OFCOMPANY