a1 waitara public school redevelopment 68 … · s9.02 elevations sheet 1 s9.03 elevations sheet 2...
TRANSCRIPT
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
TITLE SHEET & DRAWING LIST
S.W. T.M.
P.R. R.K.
18380-S1.00
JULY 2018
WAITARA PUBLIC SCHOOL REDEVELOPMENT68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
FOR CONSTRUCTION
DRAWING LISTDRAWING No. DRAWING TITLE
S1.00 TITLE SHEET & DRAWING LIST
S1.01 CONSTRUCTION NOTES
S2.00 FOOTING PLAN
S2.01 FOOTING DETAILS - SHEET 1
S2.02 FOOTING DETAILS - SHEET 2
S3.00 COLUMN DETAILS
S3.01 WALL ELEVATION SHEET 1
S3.02 WALL ELEVATION SHEET 2
S3.03 WALL ELEVATION SHEET 3
S3.04 WALL DETAILS
S4.00 LEVEL 1 FLOOR PLAN
S4.01 LEVEL 1 DETAILS
S5.00 LEVEL 2 FLOOR PLAN
S5.01 LEVEL 2 DETAILS
S6.00 LEVEL 3 FLOOR PLAN
S6.01 LEVEL 3 DETAILS
S7.00 LEVEL 4 FLOOR PLAN
S8.00 ROOF FLOOR PLAN
S9.00 ROOF FRAMING PLAN
S9.01 STEEL FRAMING PART PLANS
S9.02 ELEVATIONS SHEET 1
S9.03 ELEVATIONS SHEET 2
S9.04 ELEVATIONS SHEET 3
S9.05 STEEL DETAILS SHEET 1
S9.06 STEEL DETAILS SHEET 2
S9.07 STEEL DETAILS SHEET 3
S10.00 STAIR DETAILS
1 PRELIMINARY ISSUE S.W. P.R. 09.08.2018
2 TENDER ISSUE S.W. P.R. 31.08.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
STEELWORK ERECTION GUIDE:
SE1 THIS GUIDE IS ONLY INTENDED TO PROVIDE THE STEEL ERECTOR WITH A RECOMMENDED
PROCEDURE FOR ERECTING THE STEELWORK SAFELY AND EFFICIENTLY.
THE FABRICATION AND ERECTION OF THE STRUCTURAL STEELWORK SHALL BE
SUPERVISED BY A COMPETENT PERSON IN ORDER TO ENSURE THAT ALL REQUIREMENTS
OF THE DESIGN ARE MET. HENRY & HYMAS WILL NOT BE LIABLE FOR THE QUALITY OF
ERECTION NOR ASSUME ANY RESPONSIBILITY FOR ANY CONSTRUCTION DEFECTS
RESULTING FROM IMPROPER ERECTION TECHNIQUES OR NEGLIGENCE OF OTHER PARTIES.
SE2 THE STEEL ERECTOR MUST BE A COMPETENT PERSON FAMILIAR WITH THE FOLLOWING
STANDARDS/ MANUALS AND OTHER INDUSTRY PRACTISES & GUIDELINES.
i) AS / NZS 5131-2016 : STRUCTURAL STEELWORK - FABRICATION AND ERECTION
ii) AS 4100-1998 : STEEL STRUCTURES
iii) PRACTICAL GUIDE TO PLANNING THE SAFE ERECTION OF STEEL
STRUCTURES (1ST EDITION) - AUSTRALIAN STEEL INSTITUTE, OCT. 2016
iv) SAFE DESIGN OF STRUCTURES CODE OF PRACTICE – SAFEWORK AUSTRALIA, JULY 2014
SE3 THE CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTORS
ON SITE. CONTRACTORS ARE RESPONSIBLE FOR FULL COMPLIANCE WITH ALL THE SAFETY
REQUIREMENTS OF THE GOVERNING REGULATORY AUTHORITY AS WELL AS ANY
ADDITIONAL REQUIREMENTS IMPOSED BY THE DEVELOPER.
SE4 THE STRUCTURE MUST NOT BE SUBJECT TO EXCESSIVE CONSTRUCTION LOADING SUCH
AS MATERIAL STACKING UNLESS EXPLICITLY NOTED ON THE DESIGN DRAWINGS.
SE5 ALL GUY ROPES AND PROPS SHALL BE DESIGNED BY A COMPETENT PERSON FOR AN
OUT-OF-PLANE LOAD EQUAL TO 2.5% OF GRAVITY LOADS PLUS WIND LOADS ARISING FROM
A 100 YEAR RETURN PERIOD. LONG SPAN RAFTERS/ TRUSSES MUST BE BRACED AGAINST
TWISTING AND BUCKLING.
SE6 OUTLINED BELOW IS HENRY & HYMAS' RECOMMENDED PROCEDURE FOR STEEL ERECTION. THE
STEEL ERECTORMUST SUBMIT A DETAILED ERECTION SEQUENCE METHODOLOGY INCLUDING THE
'WITNESS AND HOLD POINTS' AND ANY DEVIATIONS FROM THE RECOMMENDED PROCEDURE FOR
REVIEW BY HENRY & HYMAS PRIOR TO ERECTING ANY STEELWORK.
SE7 STEELWORK ERECTION SEQUENCE - STEEL FRAMED STRUCTURE
STEP 1 ERECT COLUMNS ALONG GRID X FROM GRID A TO B AND BRACE THEM WITH GUY
ROPES OR PROPS TO RESTRAIN AGAINST POTENTIAL SWAY IN ANY DIRECTION. ERECT
RAFTERS ALONG THE SAME GRID LINE STARTING FROM GRID A.
STEP 2 ERECT COLUMNS AND RAFTERS ALONG GRID X+1 AND PROGRESSIVELY ATTACH
LEAD PURLINS/ STRUTS AND DIAGONAL BRACINGS BACK TO THE FRAME
ALREADY ERECTED. SQUARE AND PLUMB BRACED BAYS BEFORE MOVING TO
STEP 3.
STEP 3 PROCEED WITH THE ERECTION OF THE REMAINING FRAMES ALONG GRIDS X+2 TO X+N
INCLUDING ANY VERTICAL BRACING.
STEP 4 TEMPORARY BRACING MAY BE REMOVED AFTER ALL THE PRIMARY MEMBERS SUCH AS
COLUMNS, RAFTERS AND WALL/ ROOF BRACING ELEMENTS HAVE BEEN ERECTED AND
SIGNED OFF BY HENRY & HYMAS, OR WHEN SUFFICIENT LATERAL STABILITY HAS BEEN
ACHIEVED. INSTALLATION OF SECONDARY COMPONENTS SUCH AS PURLINS, GIRTS, FLY
BRACING, FASCIA TRUSSES ETC. SHOULD FOLLOW.
Element SlumpMax
Agg.
Cement
TypeAdmix
Cocrete
Grade
Exposure
Classif'n
Fire
Resistanc
e Rating
Cover
U.N.O.
Mass conc.
Footings/Piers 80 20 GP NIL 25 MPa A2 - -
Reinforced
Footings/Pires 80 20 GP NIL 32 MPa A2 - 50
Columns 80 20 GP NIL 40 MPa A1 2 hr 50
Walls 80 20 GP NIL 40 MPa A1 2 hr 45
Core Filling
Grout230±30 10 GP NIL 20 MPa B1 - -
External Slab
on ground80 20 SL NIL 32 MPa B1 - 40
Internal Slab
on Ground80 20 SL NIL 32 MPa A1 - 30
External
Suspended
Slabs/Beams
80 20 SL NIL 32 MPa B1 2 hr 40
Internal
Suspended
Slabs/Beams
80 20 SL NIL 32 MPa A1 2 hr 25
Tilt-up Wall
Panels80 20 SL NIL 32 MPa B1 2 hr 45
BAR SIZE MINIMUM LAP LENGTH
N10 300 (300)
N12 400 (500)
N16 600 (800)
N20 800 (1000)
N24 1000 (1300)
N28 1200 (1600)
N32 1500 (1900)
N36 1700 (2200)
TYPE OF WELD AND
CATEGORYEXAMINATION METHOD
EXTENT (% TOTAL
LENGTH OF WELD)
FILLET WELDS, GP.SP VISUAL INSPECTION 100%
BUTT WELDS, GP VISUAL INSPECTION 100%
BUTT WELD, SP VISUAL INSPECTION 100%
BUTT WELD SP RADIOGRAPHIC OR
ULTRASONIC INSPECTION
10%
NOTE:
1. ALL CONCRETE WITH SHRINKAGE LIMITED (SL) CEMENT SHALL HAVE A MAXIMUM
SHRINKAGE STRAIN OF 650 MICROSTRAINS AS DETERMINED BY TEST IN
ACCORDANCE WITH AS 1012.13 AFTER 8 WEEKS OF DRYING.
2. WATER CEMENT RATIO OF CONCRETE SHALL NOT EXCEED 0.55 (EXCEPT FOR CORE
FILLING GROUT IN BLOCK WALLS)
(REGION A) V1000 = 46 m/s
3
PSM3331-007R BY PELLS SULLIVAN MEYNINK DATED 5/9/2017
PAD/STRIP FOOTINGS - 150 kPa
PIERS - 1500 kPa -- REFER PIER SCHEDULE
PSM3331-007R BY PELLS SULLIVAN MEYNINK
THESE DRAWINGS AND NOTES SHALL BE READ IN CONJUNCTION WITH ALL
ARCHITECTURAL AND OTHER CONSULTANT'S DRAWINGS, REPORTS,
SPECIFICATIONS AND ANY OTHER WRITTEN INSTRUCTIONS AS MAY BE ISSUED
DURING THE COURSE OF CONSTRUCTION. ALL DISCREPANCIES SHALL BE
REFERRED TO THE ENGINEER FOR CLARIFICATION OR DECISION BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION FROM THESE DRAWINGS SHALL NOT COMMENCE UNTIL THEY
ARE APPROVED BY THE RELEVANT AUTHORITIES.
DIMENSIONS SHALL NOT BE OBTAINED FROM THE STRUCTURAL DRAWINGS BY
WAY OF SCALING (OR DETERMINING UNDIMENSIONED MEASUREMENTS FROM
THE ELECTRONIC DRAWING). WALL, PIER, AND COLUMN THICKNESS', AND
STRUCTURAL MEMBER SIZES SHOWN ON THESE DRAWINGS SHALL TAKE
PRECEDENCE OVER THOSE SHOWN ON THE ARCHITECT'S DRAWINGS. THE
BUILDER SHALL VERIFY ALL DIMENSIONS ON SITE AND BE RESPONSIBLE FOR
THE SETTING OUT OF THE BUILDING.
ELEMENTS INDICATED ON THESE DRAWINGS ARE SHOWN IN THEIR INTENDED
COMPLETE STATE. THE BUILDER SHALL PROVIDE ANY TEMPORARY WORKS
INCLUDING PROPPING, BRACING, SHORING AND ANY OTHER REQUIREMENTS
NECESSARY TO MAINTAIN THE STRUCTURE, OR ANY PART OF IT, IN A STABLE
CONDITION DURING CONSTRUCTION. IF THE BUILDER IS IN ANY DOUBT AS TO
HOW TO ACHIEVE THIS HE SHALL OBTAIN ADVICE FROM APPROPRIATELY
QUALIFIED AND EXPERIENCED PERSONNEL. UNLESS STATED OTHERWISE
TEMPORARY WORKS SHALL BE THE BUILDERS RESPONSIBILITY.
THE BUILDING SHALL NOT BE ERECTED ON OR ADJACENT TO ANY OF THE
FOLLOWING HAZARDS UNLESS THE HAZARD IS INDICATED ON THE STRUCTURAL
DRAWING:- EMBANKMENTS, BATTERS, WATER RETAINING STRUCTURES,
RETAINING WALLS, PITS, SEWERS, SERVICE TRENCHES, DRAINAGE CHANNELS,
STREAMS OR ANY POTENTIAL SOURCE OF DAMAGE TO THE STRUCTURE. IF ANY
SUCH HAZARDS ARE ENCOUNTERED THE ENGINEER SHALL BE NOTIFIED AND HIS
APPROVAL OBTAINED BEFORE PROCEEDING.
THE BUILDER SHALL LOCATE ALL EXISTING AND PROPOSED SERVICES AND
EASEMENTS, ON AND ADJACENT TO THE SITE. THE APPROVAL OF THE
RELEVANT STATUTORY AUTHORITY AND THE ENGINEER SHALL BE OBTAINED
BEFORE BUILDING ON OR OVER ANY SERVICES OR EASEMENTS.
THE BUILDER SHALL NOT EXCAVATE BELOW THE LEVEL OF THE FOOTINGS TO
ANY EXISTING BUILDINGS WITHOUT THE WRITTEN CONSENT OF THE ENGINEER.
THE WRITTEN CONSENT OF ADJOINING PROPERTY OWNERS SHALL BE OBTAINED
BEFORE INSTALLATION OF UNDERPINNING, ANCHORING WORK, DRAINAGE LINES
OR ANY OTHER WORK BEYOND THE PROPERTY BOUNDARY.
NO HOLES OR CHASES SHALL BE MADE IN ANY STRUCTURAL ELEMENT, UNLESS
SHOWN ON THESE DRAWINGS OR WRITTEN APPROVAL OF THE ENGINEER.
A FULL DEPTH 'V' JOINT SHALL BE STRUCK IN RENDER WHERE TWO DIFFERING
STRUCTURAL MATERIALS ABUT. i.e. AT THE JUNCTION OF MASONRY WITH
CONCRETE.
ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE
RELEVANT AUSTRALIAN STANDARDS, THE BUILDING CODE OF AUSTRALIA, AND
THE REQUIREMENTS OF THE RELEVANT STATUTORY AUTHORITIES. ALL
WORKMANSHIP SHALL BE CONSISTENT WITH GOOD TRADE PRACTICE.
WATERPROOFING REQUIREMENTS SHALL BE SPECIFIED BY THE ARCHITECT AND
ARE NOT NECESSARILY INDICATED ON THESE DRAWINGS.
AUSTRALIAN STANDARDS REFERRED TO ON THESE DRAWINGS SHALL BE THE
LATEST REVISIONS OF THE NOMINATED STANDARD.
APPROVAL OF A SUBSTITUTION OR ALTERNATIVE FROM THE ENGINEER IS NOT,
IN ITSELF AUTHORISATION FOR A VARIATION.
THE ENGINEER SHALL BE GIVEN 48 HOURS NOTICE FOR INSPECTIONS.
THE WORD ENGINEER AS USED IN THESE NOTES REFERS TO AN EMPLOYEE OR
NOMINATED REPRESENTATIVE OF H & H CONSULTING ENGINEERS P/L (TRADING
AS HENRY & HYMAS)
GENERAL NOTESG1
G2
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
G13
G14
G15
G16
THIS DRAWING SHALL BE READ IN CONJUNCTION WITH THE GEOTECH REPORT,
THE ARCHITECT'S DRAWINGS AND ANY OTHER RELEVANT CONSULTANTS
DRAWINGS AND/OR SPECIFICATIONS.
ALL PILES ARE INDICATED ON PLAN WITH ASSOCIATED WORKING LOADS.
ALL PILES SHALL BE DESIGNED FOR SAFE WORKING LOADS AS INDICATED ON
PLAN. IT SHALL BE PERMISSIBLE TO DETERMINE ULTIMATE LOADS BY
MULTIPLYING THE SAFE WORKING LOADS BY A LOAD FACTOR OF 1.4
THE DESIGN, TESTING AND INSTALLATION OF ALL PILES SHALL BE IN
ACCORDANCE WITH AS2159 AND ANY OTHER RELEVANT AUSTRALIAN STANDARD
FOR THE TYPE OF PILE USED.
THE PILES SHALL BE DESIGNED BY A SUITABLY QUALIFIED ENGINEER ELIGIBLE
FOR MEMBERSHIP TO THE INSTITUTE OF ENGINEERS.
THE DESIGNER SHALL VERIFY BY SUBMITTING CALCULATIONS INDICATING THE
METHOD BY WHICH THE LOADS INDICATED ON PLAN ARE SAFELY TRANSMITTED
TO THE FOUNDATION MATERIAL. THE STRESSES INDUCED INTO THE FOUNDATION
MATERIAL BY THE PILE LOADS SHALL BE VERIFIED BY THE GEOTECHNICAL
ENGINEER.
A SOILS REPORT PREPARED BY
SHALL BE MADE AVAILABLE TO THE CONTRACTOR BY THE SUPERINTENDENT TO
ASSIST WITH THE DESIGN. IT SHALL BE THE PILING CONTRACTORS
RESPONSIBILITY TO DETERMINE PILE LENGTHS FROM THESE REPORTS AND
GATHER ANY FURTHER INFORMATION WHICH MAY BE REQUIRED THAT IS NOT
INCLUDED IN THE REPORT FOR THE DESIGN OF THE PILES.
IT SHALL BE THE PILING CONTRACTORS RESPONSIBILITY TO CUT OFF ALL PILES
AT SURFACE LEVEL.
PIER FOUNDING LEVELS SHALL BE AS NOTED IN PIER SCHEDULE.
THE PILING CONTRACTOR SHALL FURNISH THE BUILDER WITH A WORK AS
EXECUTED SURVEY OF THE PLAN POSITION OF ALL PILES RELEVANT TO THE
BUILDING GRID. THIS SHALL BE PREPARED BY A QUALIFIED SURVEYOR.
UNLESS THE PILING CONTRACTOR CAN DEMONSTRATE OTHERWISE, ANY PILES
WHICH ARE OUT OF POSITION BY MORE THAN 75mm SHALL BE REFERRED TO THE
STRUCTURAL ENGINEER FOR THE DESIGN OF SUITABLE RECTIFICATION BEAMS.
UPON COMPLETION THE PILING CONTRACTOR SHALL CERTIFY THAT THE PILES
HAVE BEEN DESIGNED BY A SUITABLY QUALIFIED ENGINEER, TESTED IF
NECESSARY AND INSTALLED IN ACCORDANCE WITH AS2159 TO SAFELY CARRY
THE LOADS INDICATED ON PLAN.
PILE NOTESP1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
FORMWORK SHALL BE DESIGNED, CONSTRUCTED AND STRIPPED IN ACCORDANCE
WITH AS 3610.
THE DESIGN, CONSTRUCTION, CERTIFICATION AND PERFORMANCE OF FORMWORK,
FALSEWORK, AND ITS SUPPORT, IS THE RESPONSIBILITY OF THE CONTRACTOR.
DESIGN INFORMATION CONCERNING THE GROUND SUPPORT OF FORMWORK AND
FALSEWORK SHALL BE DETERMINED FROM THE CONDITIONS EXISTING ON SITE AT
THE TIME OF CONSTRUCTION.
THE FORMWORK SHALL BE DESIGNED TO RELY ON NO RESTRAINT OR STABILITY
FROM THE PERMANENT STRUCTURE WITHOUT PRIOR APPROVAL FROM THE
ENGINEER.
WHERE APPLICABLE, THE FORMWORK SHALL BE DESIGNED TO ACCOMMODATE
MOVEMENT AND LOAD REDISTRIBUTION DUE TO POST-TENSIONING.
THE FORMWORK DESIGNER MAY NEED TO CONSULT THE POST-TENSIONING
SUBCONTRACTOR TO ACHIEVE THIS.
SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE APPLIED FINISHES. BEAM DEPTHS
ARE WRITTEN FIRST AND INCLUDE THE SLAB THICKNESS. FOR CHAMFERS, DRIP
GROOVES, REGLETS etc. REFER TO THE ARCHITECT'S DRAWINGS AND/OR
SPECIFICATION.
PROVIDE UPWARD CAMBER OF FORMWORK TO SLABS AND BEAMS WHERE NOTED ON
THESE DRAWINGS. ALSO APPLY AN UPWARD PRE-SET OF L/120 TO CANTILEVERS
WHERE L IS THE SHORTEST PROJECTION FROM THE COLUMN OR WALL FACE. THE
FORMWORKER SHALL MAKE THE BUILDER AND CONCRETOR FULLY AWARE OF WHERE
FORMWORK IS CAMBERED OR PRE-SET IN ORDER THAT THE FULL DEPTH OF THE
MEMBERS IS ACHIEVED DURING CONCRETING.
FOR HORIZONTAL REINFORCED CONCRETE ELEMENTS, FORMWORK MAY BE STRIPPED
WHEN THE CONCRETE HAS REACHED 80% OF ITS SPECIFIED 28 DAY STRENGTH
UNLESS STRIPPING TIMES ARE OTHERWISE NOTED ON THE DRAWINGS.
ALTERNATIVELY, FORMWORK MAY BE STRIPPED AND PROGRESSIVELY BACK
PROPPED AFTER 5 DAYS. THE PROPS SHALL REMAIN IN PLACE UNTIL THE CONCRETE
HAS REACHED 80% OF ITS SPECIFIED 28 DAY STRENGTH.
VERTICAL FORMS TO BEAM SIDES, COLUMNS AND WALLS (UNLOADED) MAY BE
STRIPPED AFTER 3 DAYS AND WHEN THE FORMWORKER IS SATISFIED STRIPPING WILL
NOT DAMAGE THE GREEN CONCRETE.
STRIPPING AND BACK PROPPING TO POST-TENSIONED SLABS SHALL BE AS DIRECTED
BY THE STRESSING DESIGNER.
CONSTRUCTION AND SUPPORT PROPPING SHALL BE ADDED, OR LEFT IN PLACE, TO
AVOID OVERSTRESSING THE STRUCTURE DUE TO CONSTRUCTION LOADING.
THE FORMWORKER SHALL PROVIDE CLEANOUTS TO ALL COLUMNS - LEAVE OPEN
FOR ENGINEERS INSPECTION, THEN CLOSE OFF IMMEDIATELY PRIOR TO POURING.
IN MULTI STOREY CONSTRUCTION PROPPING SHALL BE PROVIDED FOR AT LEAST
3 LEVELS BELOW THE FLOOR BEING CAST. PROP REMOVAL SHALL BE PROGRAMMED
TO AVOID DISTRESS TO PREVIOUSLY CAST FLOORS. RE-SHORING OR BACK PROPPING
IS SUBJECT TO THE APPROVAL OF THE ENGINEER.
REFER TO THE ARCHITECTS SPECIFICATION FOR THE CLASS SURFACE FINISH TO
FORMED SURFACES REQUIRED.
FORMWORK:
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 3600 AND
ANY OTHER RELEVANT AUSTRALIAN STANDARDS UNLESS VARIED BY THE ENGINEER.
HOLES, PENETRATIONS, CHASES AND CONSTRUCTION JOINTS, OTHER THAN THOSE
SHOWN ON THE STRUCTURAL DRAWINGS SHALL NOT BE MADE IN CONCRETE MEMBERS
WITHOUT THE PRIOR APPROVAL OF THE ENGINEER.
CONSTRUCTION JOINTS SHALL BE PROPERLY FORMED WHERE VERTICAL. THE FIRST
POUR SHALL BE THOROUGHLY SCABBLED AND CLEANED OF ALL POORLY COMPACTED
MATERIAL AND LAITANCE, THOROUGHLY SOAKED AND PAINTED WITH A 2:1 SAND
CEMENT SLURRY IMMEDIATELY BEFORE PLACING THE SECOND POUR. THOROUGHLY
COMPACT THE SECOND POUR AGAINST THE FIRST POUR.
CONDUITS, PIPES AND THE LIKE SHALL BE PLACED WITHIN THE MIDDLE THIRD OF
THE SLAB DEPTH AND AT A MINIMUM SPACING OF NOT LESS THAN 3 DIAMETERS.
CONDUITS AND PIPES SHALL NOT BE PLACED WITHIN THE CONCRETE COVER
OUTLINED BELOW.
THE FINISHED CONCRETE SHALL BE FULLY MECHANICALLY VIBRATED TO ACHIEVE
FULL COMPACTION, COMPLETELY FILLING FORMWORK, THOROUGHLY EMBEDDING THE
REINFORCEMENT AND FREE OF STONE POCKETS. ALL CONCRETE, INCLUDING SLABS
ON GROUND AND FOOTINGS, SHALL BE FULLY VIBRATED USING A HIGH FREQUENCY
MECHANICAL VIBRATOR.
ALL CONCRETE SHALL BE PROPERLY CURED. CURING SHALL COMMENCE WITHIN
2 HOURS OF POURING AND SHALL CONTINUE FOR A MINIMUM OF 7 DAYS, FOLLOWED BY
A GRADUAL DRYING OUT. CURING SHALL BE BY CONTINUOUS SATURATION WITH
POTABLE WATER OR BY USE OF AN APPROVED PROPRIETARY CURING COMPOUND
COMPLYING WITH AS 3799, APPLIED UNIFORMLY IN ACCORDANCE WITH THE
MANUFACTURERS INSTRUCTIONS. THE COMPATIBILITY OF CURING COMPOUNDS WITH
PROPOSED APPLIED FINISHES SHALL BE VERIFIED PRIOR TO APPLICATION.
FORMED SURFACES EXPOSED WITHIN 14 DAYS OF CASTING SHALL BE SPRAYED WITH
AN APPROPRIATE CURING AGENT IMMEDIATELY UPON EXPOSURE.
SPECIFICATION OF CONCRETE:
WHERE A VAPOUR BARRIER IS SPECIFIED BENEATH SLABS ON GROUND PROVIDE A
0.2mm BRANDED POLYTHENE MEMBRANE THROUGHOUT. LAP SHEETS 300mm AND SEAL
WITH A 50mm WIDE PRESSURE SENSITIVE WATERPROOF TAPE.
WHERE CONCRETE SLABS BEAR ON MASONRY, INCLUDING CORED BRICKS, THE
BEARING SURFACE OF THE MASONRY SHALL BE RENDERED WITH 1:3 CEMENT SAND
MORTAR TO GIVE A LEVEL SURFACE AND A METAL SLIP JOINT LAID PROTECTED
BY 0.2mm POLYTHENE SHEET TAPED TO FORMWORK BEFORE PLACING CONCRETE.
SPECIAL DETAILS SHALL APPLY FOR ROOF SLABS OR SIMILARLY EXPOSED SLABS.
NON LOADBEARING MASONRY SHALL BE SEPARATED FROM THE SOFFIT OF SLABS
AND BEAMS BY 12mm CANITE OR OTHER MEANS APPROVED BY THE ENGINEER.
BEFORE THE COMMENCEMENT OF CONCRETING THE BUILDER SHALL ENSURE THE
CONCRETOR IS FULLY AWARE OF ANY AREAS OF FORMWORK THAT HAVE BEEN
PRE-CAMBERED OR PRE-SET. EXTREME CARE MUST BE TAKEN TO ENSURE THE
SPECIFIED DEPTHS OF BEAMS AND SLABS ARE ACHIEVED IN AREAS OF PRE-SETOR
PRE-CAMBERED FORMWORK. THIS CANNOT BE ACHIEVED BY LEVELLING THE
CONCRETE SURFACE INTO THE NOMINAL FINISHED CONCRETE LEVEL.
CONSTRUCTION AND SUPPORT PROPPING SHALL BE ADDED, OR LEFT IN PLACE, TO
AVOID OVERSTRESSING THE STRUCTURE DUE TO CONSTRUCTION LOADS.
NO MASONRY OR PARTITION WALLS SHALL BE CONSTRUCTED ON SUSPENDED
LEVELS UNTIL 7 DAYS AFTER PROPPING HAS BEEN REMOVED AND THE SLAB
PRE-LOADED WITH THE BRICKS OR MATERIALS TO BE USED IN THE WALL.
CONCRETE:C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
REFER TO THE CONCRETE NOTES FOR THE SPECIFIED COVERS TO REINFORCEMENT.
COVER MUST BE MAINTAINED AT ALL CHAMFERS, DRIP GROOVES AND REGLETS etc.
UNLESS NOTED OTHERWISE ON THE DRAWINGS.
REINFORCEMENT IS SHOWN DIAGRAMATICALLY. IT IS NOT NECESSARILY SHOWN IN
TRUE PROJECTION.
REINFORCEMENT SHALL NOT BE CUT OR WELDED ON SITE WITHOUT APPROVAL BY
THE ENGINEER. AT SMALL HOLES LESS THAN 300mm DIAMETER, eg PLUMBING
PENETRATIONS, BARS SHALL BE DISPLACED TO EITHER SIDE.
SITE BENDING OF REINFORCEMENT SHALL BE AVOIDED IF POSSIBLE. WHERE SITE
BENDING IS SPECIFIED, OR UNAVOIDABLE, IT SHALL BE CARRIED OUT COLD, WITHOUT
THE APPLICATION OF HEAT, AND IN ACCORDANCE WITH THE PRACTICE NOTE RPN1 OF
THE STEEL REINFORCEMENT INSTITUTE OF AUSTRALIA.
SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN THE POSITIONS SHOWN. THE
WRITTEN APPROVAL OF THE ENGINEER SHALL BE OBTAINED FOR ANY OTHER SPLICES.
WHERE LAP LENGTHS ARE NOT SHOWN THEY SHALL BE AS INDICATED BELOW:
* LENGTHS SHOWN IN BRACKETS APPLY TO HORIZONTAL BARS WITH MORE THAN 300mm
OF CONCRETE CAST BELOW THE BAR.
THE ABOVE DEVELOPMENT LENGTHS ARE FOR MAIN REINFORCEMENT IN f'c=32 MPa
CONCRETE WITH 30mm CLEAR COVER FOR WALLS AND SLABS AND 30mm CLEAR COVER
TO MIN. R10 FITMENTS FOR COLUMNS AND BEAMS.
REINFORCEMENT SYMBOLS:
N - DENOTES D500N DEFORMED BAR TO AS 4671
R - DENOTES 250R HOT ROLLED PLAIN BAR TO AS 4671
SL/RL - DENOTES HARD DRAWN WIRE REINFORCEMENT FABRIC TO AS 4671
W - DENOTES R500L HARD DRAWN PLAIN WIRE TO AS 4671
FABRIC REINFORCEMENT SHALL BE LAPPED TWO TRANSVERSE WIRES PLUS 50mm.
JOGGLES TO BARS SHALL COMPRISE A LENGTH OF 12 BAR DIAMETERS BETWEEN
BEGINNING AND END OF AN OFFSET OF ONE BAR DIAMETER.
ALL REINFORCEMENT SHALL BE CHAIRED AT MAXIMUM CENTERS AS FOLLOWS:-
BARS - 800 CENTERS EACH WAY
FABRIC - 600 CENTERS EACH WAY
EXTRA CHAIRS MAY BE REQUIRED ADJACENT TO SLAB EDGES AND JOINTS TO
PREVENT THE UPWARD DEFLECTION OF THE FABRIC WHEN STOOD ON.
ALL STEEL CHAIRS SHALL BE PLASTIC TIPPED. STEEL CHAIRS SHALL ONLY BE USED
FOR EXPOSURE CONDITIONS A1 AND A2. FULLY PLASTIC CHAIRS ONLY SHALL BE
USED ON ELEMENT FACES HAVING EXTERNAL EXPOSURE IN THE COMPLETED
STRUCTURE. WHERE REINFORCEMENT IS GROUND SUPPORTED PROVIDE PLATES
UNDER ALL BAR CHAIRS.
AT THE END SUPPORT OF A SLAB ON A MASONRY WALL, ALL BOTTOM
REINFORCEMENT SHALL EXTEND OVER THE MASONRY WALL BY 75mm FOR N12 BARS OR
95mm FOR N16 BARS. IF COVER REQUIREMENTS PROHIBIT THIS THE BARS SHALL
BE COGGED.
REINFORCEMENT:R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
•
•
•
•
•
a.
b.
c.
d.
THE BUILDER SHALL PROVIDE CONSTANT SUPERVISION OF CONCRETE POURS
EXECUTED BY SUB-CONTRACTORS TO ENSURE:
REINFORCEMENT DISPLACED OFF CHAIRS ARE REPLACED PRIOR TO
CONCRETE
NO SITE WATER IS ADDED TO CONCRETE OR CONCRETE IN WAITING
TRUCKS. (REQUIRED SLUMP FOR PLACEMENT SHALL BE ACHIEVED USING
SUPER PLASTICISER).
ALL CONCRETE IS FULLY COMPACTED USING A POKER VIBRATOR.
NO POURS ARE EXECUTED WHEN THE AMBIENT TEMPERATURE EQUALS OR
EXCEEDS 35°C.
POURS ARE PROTECTED FROM ANY HOT DRYING WINDS.
FINAL SURFACE COMPACTION SHALL BE ACHIEVED USING A TWO HEAD
'RIDE ON' POWER TROWEL.
THE FINISHED CONCRETE SHALL BE CURED FOR A MINIMUM OF SEVEN DAYS
USING AT LEAST ONE OF THE FOLLOWING METHODS:
PONDING OR CONTINUOUS SPRINKLING WITH WATER.
THE USE OF AN ABSORBENT COVER KEPT CONSTANTLY WET. (WHEN THE
AMBIENT TEMPERATURE EXCEEDS 32°C CURING MAY ONLY BE ACHIEVED
USING METHODS a AND b).
THE USE OF AN IMPERMEABLE SHEET MEMBRANE OVER A MOISTENED
SURFACE. (THE MEMBRANE SHALL BE FIXED AND LAPPED SO THAT NO AIR
CIRCULATION CAN OCCUR AT THE CONCRETE SURFACE).
THE USE OF A CURING COMPOUND COMPLYING WITH AS3799, APPLIED
UNIFORMLY IN ACCORDANCE WITH THE MANUFACTURERS
RECOMMENDATIONS, AND WHEN DRY THE COAT SHOULD BE CONTINUOUS,
FLEXIBLE AND WITHOUT VISIBLE BREAKS OR PIN HOLES FOR SEVEN DAYS.
FLOOR SLAB CONSTRUCTION:FS1
FS2
FS3
TWO COPIES OF SHOP DETAIL DRAWINGS SHALL BE SUBMITTED TO ENGINEERS
AND APPROVAL OF SAME OBTAINED BEFORE COMMENCING FABRICATION,
APPROVAL WILL NOT COVER DIMENSIONS OF LAYOUT.
STEEL SHALL BE GRADE 350 FOR HOLLOW SECTIONS AND
GRADE 300 FOR ALL ROLLED SECTIONS U.N.O.
STEEL FABRICATOR SHALL PROVIDE ALL CERTIFICATION FOR QUALITY AND
GRADE OF STEEL AND STRUCTURAL BOLTS, AND H & H ENGINEERS WILL REVIEW
CERTIFICATION AND CONFIRM THAT IT COMPLIES WITH RELEVANT STANDARDS.
BOLTS ARE DESIGNATED ON THE DRAWINGS BY THE NUMBER, DIAMETER,
GRADE AND TIGHTENING PROCEDURE IN ACCORDANCE WITH A.I.S.C. BOLTING
PROCEDURES (STANDARDISED STRUCTURAL CONNECTIONS) AND A.S.4100.
UNLESS OTHERWISE NOTED, WELDS SHALL BE 6mm CATEGORY SP CONTINUOUS
FILLET LAID DOWN WITH APPROVED COVERED ELECTRODE. BOLTS SHALL BE M20 8.8/S,
min. 2 BOLTS PER CONNECTION. CLEATS AND GUSSETS SHALL BE 10mm THICK.
ALL CLEATS AND DRILLINGS FOR FIXING OF TIMBER MEMBERS etc. SHALL BE
PROVIDED BY FABRICATOR.
CAMBER TO STRUCTURAL STEEL ROOF BEAMS, TRUSSES, PORTALS etc. SHALL BE 5mm FOR
EVERY 2000 OF SPAN UNLESS OTHERWISE NOTED.
ALL STRUCTURAL STEELWORK BELOW GROUND SHALL BE ENCASED IN CONCRETE
MINIMUM 75mm ALL AROUND.
TRANSLUCENT SHEETING SHALL BE OF GAUGE COMPATIBLE WITH PURLIN SPACING
IF STANDARD GAUGE IS USED THEN ADDITIONAL C10012 PURLIN TRIMMERS SHALL BE
PROVIDED TO GIVE SUPPORT TO SHEETING AT 1200 CENTRES MAX. SAFETY MESH UNDER
TRANSLUCENT SHEETING SHALL CONFORM WITH WORKCOVER REQUIREMENTS.
ALL STRUCTURAL STEELWORK SHALL BE GRIT BLASTED TO CLASS 2.5 AND
PAINTED WITH BLUE ZINC PHOSPHATE 75um DRY FILM THICKNESS
UNLESS NOTED OTHERWISE IN ARCHITECTS SPECIFICATION.
ALL STRUCTURAL STEEL MEMBERS SPECIFIED ON THE DRAWINGS OR OTHER RELATED
CONTRACTS AS BEING GALVANISED SHALL CONFORM TO THE REQUIREMENTS OF A.S.4680.
THE MINIMUM APPLICATION RATE FOR GALVANISING SHALL BE 550g/sq.m.
ALL STRUCTURAL STEELWORK, MATERIALS, FABRICATION AND ERECTION SHALL COMPLY
WITH A.S. 4100.
WELD TESTING
THE EXTENT OF NON-DESTRUCTIVE WELD EXAMINATION SHALL BE AS NOTED BELOW
RADIOGRAPHIC OR ULTRASONIC EXAMINATION SHALL BE TO AS1554.1, AS2177.1 AND AS2307
FLASH WELDING AND TESTING OF ALL STUDS SHALL COMPLY WITH A.S.1554.2
SUSPENDED CEILINGS AND BULKHEADS, WHERE SUPPORTED BY PURLINS, SHALL BE
SUPPORTED BY WEB CONNECTION ONLY AND NOT HOOKED FROM BOTTOM LIP.
THE CONTRACTOR SHALL PROVIDE THE BUILDER WITH CERTIFICATION OF
STRUCTURAL ADEQUACY STATING COMPLIANCE WITH THE ABOVE.
ALL EXTERNAL STEELWORK SHALL BE HOT DIPPED GALVANISED
STRUCTURAL STEEL:S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH A.S. 3700
EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS
BLOCK COMPRESSIVE STRENGTH f'uc SHALL BE 15 MPa min. U.N.O
BLOCK GRADE SHOULD BE CLEARLY INDICATED ON THE DELIVERY DOCKET.
MORTAR SHALL CONSIST OF 1 PART CEMENT, 1 PART LIME AND 6 PARTS
SAND. MORTAR SHALL COMPLY WITH A.S. 3700.
REINFORCEMENT SHALL BE PLACED AND SECURELY HELD IN THE LOCATIONS
INDICATED. RODS SHALL BE TIED TO STARTER BARS IN CLEANOUT BLOCKS.
COVER TO VERTICAL REINFORCEMENT SHALL BE 50mm FROM THE OUTSIDE OF
THE BLOCK WHERE DRAWN ADJACENT TO BLOCK FACE.
MORTAR PROTRUDING INTO CORE HOLES SHALL BE REMOVED BY THE BLOCK
LAYER AFTER EACH COURSE IS LAID. EVERY CORE FILLED WITH GROUT SHALL
HAVE A CLEANOUT BLOCK IN THE BOTTOM COURSE.
CORE FILLING GROUT SHALL BE AS SET OUT IN NOTE C7.
PROVIDE MOVEMENT JOINTS EVERY 8m AND/OR OVER EVERY FLOOR JOINT U.N.O.
PROVIDE MOVEMENT JOINTS EVERY 4m IN PARAPET WALLS.
PROVIDE SMOOTH TROWELED MORTAR BED AND TWO LAYERS OF 'ALCOR' ON TOP
OF ALL LOAD BEARING WALLS WHERE SLIP JOINTS ARE NOMINATED.
BLOCKWORK:
BL1
BL2
BL3
BL4
BL5
BL6
BL7
BL8
FOOTINGS HAVE BEEN DESIGNED IN ACCORDANCE WITH GEOTECHNICAL
REPORT
FOOTINGS HAVE BEEN DESIGNED FOR THE FOLLOWING BEARING PRESSURES:
FOUNDATION MATERIAL SHALL BE APPROVED BY THE CONSULTING
GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT OF CONCRETE.
FOUNDATIONS:F1
F2
F3
SUPERIMPOSED LOADS ARE GENERALLY IN ACCORDANCE WITH AS 1170. AND AS NOTED.
WIND LOADS ARE IN ACCORDANCE WITH AS 1170 AS FOLLOWS:-
BASIC WIND VELOCITY
TERRAIN CATEGORY
EARTHQUAKE LOADS DESIGN CATEGORY = EDCII
SITE SUB-SOIL CLASS = B
HEARD FACTOR Z = 0.08
PROBABILITY FACTOR Kp = 1.3
LOADINGL1
L2
L3
WAITARA PUBLIC SCHOOL REDEVELOPMENT68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 1
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
CONSTRUCTION NOTES
S.W. T.M.
P.R. R.K.
18380-S1.01
JULY 2018
FOR CONSTRUCTION
1 PRELIMINARY ISSUE S.W. P.R. 09.08.2018
2 TENDER ISSUE S.W. P.R. 31.08.2018
3 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
HO
LD
FFL 186.500
183.5
184.
0
184.
5
185.
0
185.
5
186.0
186.
0
186.5
183.8
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
P7 P7P7 P7 P7P7 P7 P7 P7P7
P7
P7
P7P7 P7
P7
P7
P7
P7
P7
P7
P7
P7
P3 P5 P6 P4
P1 P6 P4
P1 P1 P1 P1
P3
P1
P3
P1
P3
P1
P1
P1
P5
P5 P5
P1
P1
P1 P1 P1
P1 P1
P3
P1
P1
P1
P3
P1 P1
P5
P5
P1 (U) P1 (U)
P3
P6
P1 (U)
P1 (U) P1 (U)
P1 (U)
P1 (U) P1 (U)
P1 (U)
P1 (U)
P3 (U)P1 (U)
P4 (U) P4 (U)
P2 (U) P2 (U)
P2 (U) P2 (U)
P2 (U) P2 (U)
P4 (U)
P6 (U)
P4 (U)
P4 (U)
P1
C4 C4 C8 C4
C4 C4
C2
C2
C5 C5 C5C5
C5 C5 C5
C2
C2
C2
C2 C2
C2
C2
C2C2C2
C1
C1
C1
C2 C2
C5C5C5C5
C5C5C5C5 C5
C2
C2
P7 (U)
C1
FB1
600
FB1FB3
FB3FB1
FB1
FB
1
FB
3
FB
1
FB
3
FB
1
FB
1
C1
C1
P4
P4
P1
C2
P1 (U)
P1 (U)
FB
1
1S4.01
2S4.01
BW
1
BW1
RW
1R
W1
P1 (U) P1 (U)
C2 P1
W11
W10
P1
C2
W2
W1
W3
W4
W5 W
6
W8
W12
FB1
C1
P7
P7
FB2
FB
2
RD
W1
RDW1
RD
W1
DW1
RDW1
FB2
P7 P7 P7
BH5
BH6
BH7
BH8
BH1
OUTLINE OF SLAB
OUTLINE OF SLAB
ABOVE
W7
1:1
BA
TT
ER
1:1 BATTER
W14
W13
W16
W15
C7C7
RW
1
RW1
REFER BLOCK RETAINING
WALL DETAILS ON SHEET
S2.02 FOR FOOTING DETAILS
RDW1 RDW1 RDW1
PF1 PF1
PF1
STEP IN WALL
W4a
REFER BLOCK RETAINING
WALL DETAILS ON SHEET
S2.02 FOR FOOTING DETAILS
PIER NOTES:
1. ALL PIER FOUNDATION MATERIAL SHALL BE INSPECTED BY
A QUALIFIED GEOTECHNICAL ENGINEER TO VERIFY THAT THE
DESIGN AND SOIL PARAMETERS SCHEDULED HAVE BEEN
ACHIEVED ON SITE.
2. DESIGN END BEARING - 1500 kPa
3. DESIGN SHAFT ADHESION - 150 kPa
4. ALL PIERS TO COLUMNS SHALL BE SET OUT ON COLUMN
CENTRELINE (REFER ARCHITECT'S DRAWINGS FOR SET OUT)
5. THE PROJECT DATUM AS NOMINATED BELOW SHALL BE
(REFER ARCHITECT'S DRAWINGS FOR FSL)
6. PC ++++ (WHERE APPLICABLE)
DENOTES TOP OF PIER CAP LEVEL RELATIVE
TO THE PROJECT DATUM LEVEL
(REFER NOTE 5 ABOVE)
7. P ++++ DENOTES TOP OF PIER LEVEL RELATIVE
TO THE PROJECT DATUM LEVEL
(REFER NOTE 5 ABOVE)
8. ALL TOP OF PIER SHALL BE P -400 UNO.
9. PIER TAG
P+ - (PIER NUMBER/TYPE)
PC+ - (PIER CAP NUMBER/TYPE)
C+ - (COLUMN NUMBER/TYPE)
SP+ - (SCREW PILE NUMBER/TYPE)
SITE PREPARATION NOTES:
1. SITE PREPARATION SHALL BE CARRIED OUT IN ACCORDANCE WITH
THE GEOTECHNICAL ENGINEERS REPORT NO. PSM3331-007R
PREPARED BY PELLS SULLIVAN MEYNINK AND THE FOLLOWING NOTES.
2. FOLLOWING DEMOLITION REMOVE FROM THE SITE ALL RUBBLE,
TOPSOIL, VEGETATION AND ROOT AFFECTED TOPSOIL. MANSORY
BUILDING RUBBLE MAY BE CRUSHED TO A MAX. PARTICLE SIZE OF
20mm AND STOCKPILED FOR A SITE FILLING. TOPSOIL MAY BE STOCK
PILED FOR RE-USE IN LANDSCAPED ZONES.
3. IN ACCORDANCE WITH THE J&K REPORT ABOVE, THE ENTIRE SITE IS
OVERLAYED WITH UNCONTROLLED FILL OF VARIABLE DEPT:
- ALL EXISTING FILL SHALL BE EXCAVATED AND STOCKPILED FOR
REUSE SUBJECT TO GEOTECH APPROVAL OR APPROPRIATELY
REMOVED FROM SITE.
- PROOF ROLL THE EXPOSED SUBGRADE WITH VIBRATING STEEL
DRUM ROLLER OF MIN. 8-10 TONNE DEADWEIGHT UNDER THE
SUPERVISION OF AN EXPERIENCED GEOTECHNICAL ENGINEER.
- REMOVE AND REPLACE ANY SOFT OR HEAVING AREAS AS DIRECTED
AND +2% OF STANDARD OPTIMUM MOISTURE CONTEN.
4. UPON COMPLETION OF SUBGRADE PREPARATION THE SITTE MAY BE
FILLED TO FINISHED BULK EARTHWORKS LEVEL:
- FILL MATERIAL SHOULD BE A WELL GRADED, GRANULAR MATERIAL
SUCH AS CRUSHED OR RIPPED SANDSTONE. ALTERNATIVE
MATERIALS MAY BE USED SUBJECT TO GEOTECHNICAL ENGINEERS
APPROVAL.
- FILL SHALL BE COMPACTED IN LAYERS OF NOT GREATER THAN 200mm
LOOSE THICKNESS, TO A DENSITY OF BETWEEN 98% - 102% OF SDD
AND +2% OF STANDARD OPTIMUM MOISTURE CONTENT.
5. THE BUILDER SHALL ENGAGE GEOTECHNICAL ENGINEERS TO
CARRY OUT LEVEL 1 EARTHWORKS SUPERVISION IN ACCORDANCE
WITH AS 3798 AND PROVIDE FINAL CERTIFICATION THAT THE FILL
PLATFORM HAS BEEN CONSTRUCTED IN ACCORDANCE WITH
REPORT No. PSM3331-007R PREPARED BY PELLS SULLIVAN MEYNINK
AND THE NOTES ABOVE.
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
FOOTING PLAN
S.W. T.M.
P.R. R.K.
18380-S2.00
JULY 2018
1 PRELIMINARY ISSUE S.W. P.R. 09.08.2018
2 TENDER ISSUE S.W. P.R. 31.08.2018
3 REVISED FOR TENDER I.S. P.R. 10.10.2018
4 REVISED FOR TENDER T.L P.R. 17.10.2018
5 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SCALE 1 : 100
FOOTING PLAN
FOR CONSTRUCTION
PIER SCHEDULE
MARK No. DIAMETERWORKINGLOAD (kN) REINFORCEMENT SOCKET LENGTH
P1 600 900 6N20 1000 INTO 1500 kPa SHALE
P2 600 1300 6N20 2000 INTO 1500 kPa SHALE
P3 750 1600 6N24 1000 INTO 1500 kPa SHALE
P4 900 1800 6N28 1000 INTO 1500 kPa SHALE
P5 900 2100 6N28 1000 INTO 1500 kPa SHALE
P6 900 2600 6N28 2000 INTO 1500 kPa SHALE
P7 300 250 6N12 3000 INTO 700 kPa SHALE
NOTE: 1500 kPa SHALE IS ASSUMED TO BE 4.0m BELOW 700 kPa (CLASS V) SHALE.
FB1 - DENOTES 600 WIDE x 600 DEEP FOOTING BEAM
FB2 - DENOTES 600 WIDE x 300 DEEP FOOTING BEAM
FB3 - DENOTES 800 WIDE x 600 DEEP FOOTING BEAM
RDW1 - 200 THICK AFS REDIWALL.
CONCRETE STRENGTH f 'c = 40 MPa
BW1 - DENOTES 190 CORE FILLED BLOCK WALLS
N16-400 EW CENTRAL.
PF1 - DENOTES PAD FOODING -- REFER DETAILS
DATUM LEVEL
TOP OF PIER LEVEL TOP OF PIER CAP LEVEL
TOP OF PIER LEVEL
ROCK LEVEL ROCK LEVEL
SFL
TOP OF STRIP FOOTING LEVEL
FSL
TOP OF STRIP FOOTING LEVEL
FSL
TOP OF STRIP FOOTING LEVEL
FSL
REINFORCED PIER ONLY REINFORCED PIER AND FOOTING BEAM
(REFER PIER SCHEDULE)
PIER
REINFORCEMENT AS NOTEDREFER PIER SCHEDULE
TYPICAL PIER SECTION
STARTER BAR AS NOTED(WHERE REQUIRED - REFER PLAN
AND DETAILS FOR LOCATION)
P ++++
REINFORCEMENT AS NOTEDREFER PIER SCHEDULE
TIES OR HELIX AS NOTEDREFER PIER SCHEDULE
(RE
FER
PIE
R S
CH
ED
ULE
)
SO
CK
ET
LEN
GTH
(RE
FER
PIE
R S
CH
ED
ULE
)
MIN
IMU
M P
IER
LE
GTH
PC ++++
50 S
OC
KE
T
DE
TAIL
S
RE
FE
R
STARTER BAR AS NOTED(WHERE REQUIRED - REFER PLAN
AND DETAILS FOR LOCATION)
REINFORCEMENT AS NOTEDREFER PIER SCHEDULE
TIES OR HELIX AS NOTEDREFER PIER SCHEDULE
(RE
FER
PIE
R S
CH
ED
ULE
)
MIN
IMU
M P
IER
LE
NG
TH
(RE
FER
PIE
R S
CH
ED
ULE
)
SO
CK
ET
LE
GTH
300 COG
100(REFER PLAN)
P ++++(REFER PLAN)
(REFER PLAN)
'Z' BARS TO MATCH FOOTING LONGITUDINAL
REINFORCEMENT REFER SCHEDULE
TIES TO MATCH FOOTING TIE SIZE AND
CTS. REFER SCHEDULE
DEPTH
EQUAL TO
SC
HE
DU
LE
DE
PT
HR
EFE
R
BR
ICK
/ B
LOC
K C
OU
RS
ING
ST
EP
DE
PTH
TO
MA
TCH
COMPACTED FILL
COMPACTED FILL
N20 AT 200 EW
N20 AT 200 EWWATERPROOF MEMBRANE
SLAB ON GROUNDAS DETAILED
LINE OF WALL BEYONDDOOR OPENNING
300 LAP(typical)
TYPICAL LIFT PIT SECTION
LIFT PIT SUMP(REFERLIFT MANUFACTURER'S
DRAWINGS FOR SIZEAND LOCATION)
600
450
450
N20 'L' BARS AT 200
N20 'Z' BARS AT 200 EF450 LEGS
N20 'L' BARS AT 200
TYPICAL LIFT PIT SUMP DETAIL
200
600
MIN
.
COMPACTED FILL
Ø100 AG DRAIN IN FILTERSOCK SURROUNDED WITH GRAVEL
(typical)
75 75
BORED PIER (REFER FOOTING PLAN)
NOTE:
1. THE CONCRETE MIX SHALL HAVE A
WATERPROOFING COMPOUND ADDED "PENETRON" OR "XYPEX" OR EQUIVALENT
IJ
CJ
REFER WALL ELEVATION DRG.FOR LIFT WALL REINFORCEMENT.
TYP
300 MIN
SL82 FABRIC BTM.40 COVER AROUND
LIFT PIT WALLS(typical)
120
TY
P.
150
TY
P.
ALTERNATIVELY TO REARGUARD PROVIDE 'PARBURY' 250W SUPERCAST
PVC HYDROFOIL OR APPROVED EQUIVALENT.
CJDIST. TO 1st HORIZ. BAR
100 17
5 CJ
.
.
200
CJ
PROVIDE 'PENEBAR' OR 'HYDROTITE' EXPANDINGWATERSTOP CENTRALLY PLACED DSS-0220.
(OR APPROVED EQUIVALENT) TYP.
THOROUGHLY SCABBLE ANDCLEAN JOINT. MOISTEN FACE & APPLY 10mm OF APPROVED BONDING AGENT OR
CEMENT SLURRY IMMEDIATELY PRIOR TO POURING WALL CONCRETE.(typical)
REARGUARD 200 WIDE TYP.
REFER WALL ELEVATION DRG.FOR LIFT WALL REINFORCEMENT.
FOOTING BEAM - FB1
600
600
( AFS LOGICWALL INDICATIVE OVER)
(REFER ARCHITECT'S DRAWING FOR LEVELS)
FOOTING BEAM - FB2
600
300
( RDW1 -- REDIWALLINDICATIVE OVER)
(REFER ARCHITECT'S DRAWING FOR LEVELS)
FOOTING BEAM - FB3
800
600
(REFER ARCHITECT'S DRAWING FOR LEVELS)
( AFS LOGICWALL INDICATIVE OVER)
4N32 T/B2N16-300 TIES
L12TM- 5WIRES TOP & BTMR10-900 TIES
6N32 T/B2N16-300 TIES
KJ
KJ
INFILL SLAB AFTER ERECTIONOF TRUCTURAL STEEL
KJ
KJ
INFILL SLAB AFTER ERECTIONOF TRUCTURAL STEEL
KJ
KJ
INFILL SLAB AFTER ERECTIONOF TRUCTURAL STEEL
SL82 MESH TOP
400
MIN
.
200
SECTION
FOR COLUMN DETAILSREFER PLAN
TYPICAL PAD FOOTING PF1 DETAIL
600x6004N16 'U' BARS E.W.
1N12 ALLROUND
This drawing and design remains the propery of Henry & Hymas and may not becopied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 20
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
FOOTING DETAILS - SHEET 1
S.W. T.M.
P.R. R.K.
18380-S2.01
JULY 2018
1 PRELIMINARY ISSUE S.W. P.R. 09.08.2018
2 TENDER ISSUE S.W. P.R. 31.08.2018
3 REVISED FOR TENDER I.S. P.R. 10.10.2018
4 REVISED FOR TENDER T.L P.R. 17.10.2018
5 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
FOR CONSTRUCTION
SCALE 1 : 20
TYPICAL PIER ELEVATIONS
SCALE 1 : 20
TYPICAL FOOTING STEP DETAIL
CAPPING OPTIONAL NATURAL BACKFILL MATERIALFOR TOP 300mm ONLY
GEOFABRICREFER NOTE 3
PROVIDE BITUMEN WATERPROOFING
TO BACK OF WALL AND JOINTSREFER NOTE 1
FREE DRAINING GRANULAR BACKFILL(GRAVEL) FOR FULL HEIGHT AND
LENGTH OF RETAINING WALL
PROVIDE CORDRAIN DRAINAGE CELLFULL HEIGHT
REFER NOTE 2
CORE FILLED BLOCKWORK.REFER BLOCKWORK NOTES ON DRG. S1.00
Ø100 AG DRAIN IN FILTERSOCK SURROUNDED
WITH GRAVEL
N16 AT 400 HORIZ(OMIT ON TOP OF
CLEAN-OUT BLOCK)
N16 AT 400 VERT.
REMOVE FACE OFBLOCK TO PROVIDEDCLEAN-OUT OPENING
AT EACH VERT. BAR
'V' BARS
55 COVER
300
250
'B'
LAP
650
MIN
.25
0
'H' (
1600
max
.)50
0
SL72 FABRIC
N16 AT 400
150 OR 200 SERIES BLOCK WALL 200 OR 300 SERIES BLOCK WALL15.0 kPa SURCHARGE
RETAINING WALL SCHEDULE RW1TOTAL HEIGHT
'H' (mm)HEIGHT OF BLOCK TYPE
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
800 -
-
-
-
-
-
1400
1600
1800
1400
1400
600
1200
1400
1600
GEOFABRICREFER NOTE 3
PROVIDE BITUMEN WATERPROOFINGTO BACK OF WALL AND JOINTS
REFER NOTE 1
FREE DRAINING GRANULAR BACKFILL(GRAVEL) FOR FULL HEIGHT AND
LENGTH OD RETAINING WALL
PROVIDE CORDRAIN DRAINAGE CELLFULL HEIGHT
REFER NOTE 2
Ø100 AG DRAIN IN FILTERSOCK SURROUNDED
WITH GRAVEL
NATURAL BACKFILL MATERIAL
FOR TOP 300mm ONLY
55 COVERCAPPING OPTIONAL
CORE FILLED BLOCKWORK.REFER BLOCKWORK
NOTES ON DRG. 1.00
N16 AT 400 VERT.
N16 AT 400 HORIZ(OMIT ON TOP OF
CLEAN-OUT BLOCK)
'K' BARS
'V' BARS
REMOVE FACE OFBLOCK TO PROVIDE
CLEAN-OUT OPENINGAT EACH VERT. BAR
300
'B'
300
600
HE
IGH
T (3
00 S
ER
IES
)H
EIG
HT
(200
SE
RIE
S)
LAP
650
min
'H' (
1800
TO
300
0)
'X' BARSN16 AT 400
SL72 FABRIC
800
1200
1500
1800
2100
2300
2500
2700
3000
3300
3500
3800
200 SERIES 300 SERIES'B' (mm) 'V' & 'X' BARS 'K' BARS
-
-
-
-
-
N16 AT 400
N16 AT 400
N16 AT 400
N16 AT 400
N16 AT 200
N16 AT 200
N20 AT 200
NOTES:
300
1000
1200
1400
1400
1400
1400
800
1000
N16 AT 400
N16 AT 400
N16 AT 200
N20 AT 200
N20 AT 200
N20 AT 200
N16 AT 200
15.0 kPa SURCHARGE
N16 AT 400
N16 AT 200
N16 AT 200
N16 AT 200
N16 AT 200
1. ENSURE REAR FACE OF RETAINING WALL IS FULLY WATERPROOFED. USE EMER-PROOF ECOFLEX OR APPROVED EQUIVALENT IN ACCORDANCE WITH MANUFACTURERS SPECIFICATION. EG: 2 COATS min. APPLIED IN OPPOSITE DIRECTIONS AND ALLOWED TO CURE FOR 7 DAYS.
( TO BE CONIRMED BY THE ARCHITECT)2. INSTALL FULL HEIGHT DRAINAGE CELL TO REAR OF WALL, USE NYLEX CORDRAIN/18 OR APPROVED EQUIVALENT.3. PROVIDE GEOFABRIC MATERIAL AS SEPARATION BETWEEN GRANULAR BACKFILL (GRAVEL) AND NATURAL BACKFILL MATERIAL. USE BIDIM A24 OR APPROVED EQUIVALENT.
4. MINIMUM ALLOWABLE BEARING PRESSURE AT BASE = 150 kPa
2-N12
40 COVER
N12-400 'L' BARS.
2-N16
This drawing and design remains the propery of Henry & Hymas and may not becopied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 20
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
FOOTING DETAILS - SHEET 2
S.W. T.M.
P.R. R.K.
18380-S2.02
JULY 2018
1 TENDER ISSUE S.W. P.R. 31.08.2018
2 REVISED FOR TENDER I.S. P.R. 10.10.2018
3 REVISED FOR TENDER T.L P.R. 17.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
FOR CONSTRUCTION
COLUMN TYPE 'C1' COLUMN TYPE 'C2' COLUMN TYPE 'C4 & C8' COLUMN TYPE 'C5'
Ø 450
500
800
400
400
Ø 600
20 CHAMFER TYPICAL.
COLUMN TYPE 'C7'
250
600
PLAN
SECTION
CJ
CJ
BA
R D
IA
LAP
30
SLABS AND BEAMS AS DETAILED
SP
LIC
E L
EN
GT
H
50 75
CRANK REINFORCEMENT1:6 MAXIMUM.
PROVIDE EXTRA TIESET AT CRANK
LOCATION (typical)
COLUMN REINFORCEMENT AS SCHEDULED
SCABBLE SURFACE (typical)
CJ
CJ
STANDARD COG(typical)
50
CJ
CJ
CJ
SLABS AND BEAMSAS DETAILED
50 75
CRANK REINFORCEMENT1:6 MAXIMUM.
PROVIDE EXTRA TIESET AT CRANK
LOCATION (typical)
CJ
CJ
50
COLUMN REINFORCEMENTAS SCHEDULED
SCABBLE SURFACE (typical)
SLABS AND BEAMSAS DETAILED
SP
LIC
E L
EN
GT
H
SP
LIC
E L
EN
GT
H
50 50
PIERS AS DETAILED
PROVIDE EXTRA TIES AT LAP LOCATIONS
(typical)IJ IJ
COLUMN STARTER BARSAS SCHEDULED
Ø40
BA
R
SP
LIC
E L
EN
GT
H
Ø40
BA
R
SP
LIC
E L
EN
GT
H
COLUMN REINFORCEMENTAS SCHEDULED
SCABBLE SURFACE (typical)
STANDARD COG(typical)
STANDARD COG(typical)
50
CJ
50
This drawing and design remains the propery of Henry & Hymas and may not becopied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 20
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
COLUMN DETAILS
S.W. T.M.
P.R. R.K.
18380-S3.00
JULY 2018
1 PRELIMINARY ISSUE S.W. P.R. 09.08.2018
2 TENDER ISSUE S.W. P.R. 31.08.2018
3 REVISED FOR TENDER I.S. P.R. 10.10.2018
4 REVISED FOR TENDER T.L P.R. 17.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SCALE 1 : 20
COLUMN SECTIONS
SCALE 1 : 20
COLUMN TRANSITION DETAILS
SCALE 1 : 20
TYPICAL COLUMN ELEVATIONS
FOR CONSTRUCTION
COLUMN SCHEDULE
COLUMN TYPE CONCRETE STRENGTHCOLUMN
REINFORCEMENT STARTER BARS TIESC1 40 MPa 10N24 10N24 2R10-300
C2 40 MPa 8N20 8N20 2R10-300
C4 40 MPa 6N20 6N20 R10-300
C5 40 MPa 8N24 8N24 R10-300
C7 40 MPa 6N24 6N24 2R10-300
C8 40 MPa 8N28 8N28 R10-300
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G'' L.V.
''C''
L.V
.
''G'' L.V.
''C'''
G
''C'''
''G''
''C'''
''G''
''C'''
''G'' L.V.
''G''
''C'''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''''C
''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G'' ''G''
''C''
''C''
''G'' ''G''
''C''
''C''
''G'' ''G''
''C''
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
W4aS3.01
NOTE:
SLAB TO REMAIN
PROPPED UNTIL WALL
UNDER HAS GAINED
FULL STRENGTH
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
W4aS3.01
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
W3S3.01
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
W3S3.01
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
W5S3.01
W4S3.01
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
W2S3.01
W1S3.01
REINFORCEMENT SCHEDULE
TAGDESIGNATION
(DIAMETER - CENTRES) CROSS-SECTIONAL AREA
(mm²/m)
'A'
'B'
'C'
'D'
'F'
'G'
N12 AT 300
N12 AT 200
N16 AT 200
N16 AT 150
N20 AT 200
N20 AT 150
367
440
1000
1333
1550
2067
'E' N16 AT 150 1333
1. ALL WALLS TO BE AFS LOGICWALL 200 THICK UNO,
CORE FILLED WITH 40 MPa CONCRETE UNO.
2. ALL BARS TO BE CENTRALLY PLACED UNO.
NOTE:
1
A
B
W2S3.01
W1S3.01
W3S3.01
W2
W1
W3
4 5
A
B
W5S3.01
W4S3.01
W4aS3.01
W4
W4a
W5
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
WALL ELEVATION SHEET 1
Author T.M.
P.R. R.K.
18380-S3.01
10/19/18
1 TENDER ISSUE I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SCALE 1 : 100
WALL W5 ELEVATIONSCALE 1 : 100
WALL W4 ELEVATION
SCALE 1 : 100
WALL W2 ELEVATIONSCALE 1 : 100
WALL W1 ELEVATION
SCALE 1 : 100
WALL W4a- ELEVATION
SCALE 1 : 100
WALL W3 ELEVATION
FOR CONSTRUCTION
SCALE 1 : 100
STAIR ST1 WALL PLAN
SCALE 1 : 100
STAIR ST2 WALL PLAN
''C''
''G''
''C''
''G'' L.V.
''C''
''G''
''C''
''G''''G''
''C''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G'' L.V.
''C''
''C''
''G'' ''G''
''G''
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
7S3.02
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
8S3.02
6S3.02
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
7S3.02
C
REFER COLUMN DETAIL
FOR REINFORCEMTN
REINFORCEMENT SCHEDULE
TAGDESIGNATION
(DIAMETER - CENTRES) CROSS-SECTIONAL AREA
(mm²/m)
'A'
'B'
'C'
'D'
'F'
'G'
N12 AT 300
N12 AT 200
N16 AT 200
N16 AT 150
N20 AT 200
N20 AT 150
367
440
1000
1333
1550
2067
'E' N16 AT 150 1333
1. ALL WALLS TO BE AFS LOGICWALL 200 THICK UNO,
CORE FILLED WITH 40 MPa CONCRETE UNO.
2. ALL BARS TO BE CENTRALLY PLACED UNO.
NOTE:
8 9
A
B
8S3.02
6S3.02
7S3.02
W6 W
8
W7
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
WALL ELEVATION SHEET 2
Author Designer
Checker Approver
18380-S3.02
01/25/19
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SECTIONSCALE 1 : 100 S3.02
8SECTIONSCALE 1 : 100 S3.02
7SECTIONSCALE 1 : 100 S3.02
6
SCALE 1 : 100
STAIR ST3 WALL PLAN
''G'' E.F.
''C''
E.F
.
''G'' E.F.
''C''
E.F
.
''G'' E.F.
G E.F.
''C''
''G''
''C''
''G''''C
''
''G''
''C''
''G''''B
'' E
.F.
''C'' E.F.
''C''
''G''''C
''
''G''
''C''
''G''
''C''
''G''
''B''
E.F
.
''C'' E.F.
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''B''
E.F
.
''C'' E.F.
''C''
''G''
''C''
''G''
''C''
''G''
''C''
''G''
''C''
G
'B' E
.F.
''C''
G
''G''
G
''C''
G
''G''
G
''C''
G
''G''
LEVEL 2
11S3.03
''C'' E.F.
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
10S3.03
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
14S3.03
16S3.03
200
TH
K R
C W
ALL
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
15S3.03
200
TH
K R
C W
ALL
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
14S3.03
16S3.03
200
TH
K R
C W
ALL
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
ROOF
13S3.03
15S3.03
''C''''C''
''G''
''C''''C''
''C'' ''C''
''C''''C''
'C' E.F. 'C' E.F.
'C' E.F.
REFER COLUMN DETAIL
FOR REINFORCEMTN
200
TH
K R
C W
ALL
5
D
13S3.03
15S3.03
14S3.03
16S3.03
W14
W13
W15
11
D
11S3.03
10S3.03
W10
W11
REINFORCEMENT SCHEDULE
TAGDESIGNATION
(DIAMETER - CENTRES)
CROSS-SECTIONAL AREA
(mm²/m)
'A'
'B'
'C'
'D'
'F'
'G'
N12 AT 300
N12 AT 200
N16 AT 200
N16 AT 150
N20 AT 200
N20 AT 150
367
440
1000
1333
1550
2067
'E' N16 AT 150 1333
1. ALL WALLS TO BE AFS LOGICWALL 200 THICK UNO,
CORE FILLED WITH 40 MPa CONCRETE UNO.
2. ALL BARS TO BE CENTRALLY PLACED UNO.
NOTE:
1
E
12S3.03
W12
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
WALL ELEVATION SHEET 3
Author Designer
Checker Approver
18380-S3.03
01/25/19
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SCALE 1 : 100
WALL W10 ELEVATIONSCALE 1 : 100
WALL W11 ELEVATION
SCALE 1 : 100
WALL W12 ELEVATION
SCALE 1 : 100
WALL W13 ELEVATIONSCALE 1 : 100
WALL W14 ELEVATIONSCALE 1 : 100
WALL W15 ELEVATIONSCALE 1 : 100
WALL W16 ELEVATION
SCALE 1 : 100
LIFT SHAFT WALL PLANSCALE 1 : 100
STAIR ST4 WALL PLANSCALE 1 : 100
WALL W12 PLAN VIEW
200 THK OFF-FORM CONCRETE. 200 THK OFF-FORM CONCRETE.
FLOOR LEVEL
TYPICAL WALL INTERSECTION ELEVATION DETAILS
600
LAP
SLAB INTERSECTION DETAIL
TRIMMER
`L' BAR SAME SIZE AND
SPACING AS HORIZONTAL
REINFORCEMENT
LAP 40 BAR DIA.
SCABBLE SURFACE
END OF WALL
'L' BARS TO MATCH
VERTICAL WALL
REINFORCEMENT
WALL DOOR OPENING
300 COG
300
CO
G
600
LAP
200 WALL - CORNER DETAIL
300 COG 300 COG
200 WALL "T" INTERSECTION DETAIL
600
LAP
'L' BARS EACH FACE
TO MATCH HORIZONTAL
WALL REINFORCEMENT
COG 300 ONE END
'L' BARS EACH FACE
TO MATCH HORIZONTAL
WALL REINFORCEMENT
200 WALL - ALTERNATIVECORNER DETAIL
300 COG 300 COG
600
LAP
'L' BARS EACH FACE
TO MATCH HORIZONTAL
WALL REINFORCEMENT
200 WALL - ALTERNATIVE"T" INTERSECTION DETAIL
TYPICAL WALL INTERSECTION PLAN DETAILS
600 LAP
600 LAP
200 AFS LOGICWALL - CORNER DETAIL 200 AFS LOGICWALL "T" INTERSECTION DETAIL
N16-300 CENTRAL 1000 LEG
HORIZONTAL REINF'T. AT
CORNERS. HOOK ONE END. TYP.
N16-300 CENTRAL 1000 LEG
HORIZONTAL REINF'T. AT
CORNERS. HOOK ONE END. TYP.
TYPICAL WALL TO COLUMN CONNECTIONFOR 200 THICK OFF-FORM CONCRETE WALLS ONLY
FOR 200 AFS WALLS ONLY
TYPICAL TEMP. MOVEMENT JOINT 'TSJ' DETAIL AT SLAB / WALL CONNECTION
'U' BARS AS SCHEDULED ON
P/T CONTRACTORS DRAWINGS
N20-200 (500 LEGS) CAST-IN 'L' BARS
CENTRAL TO P/T CONCTRACTOR'S DETAIL
(PLACED INSIDE STRESSING SLEEVES &
GROUTED 56 DAYS AFTER CONCRETE
POUR)
PROVIDE TEMPORARY BACK PROPPING
20 THICK POLYSTYRENE
AT SLAB / WALL INTERFACE
REMOVE POLYSTYRENE
AND FILL GAP WITH GROUT
56 DAYS AFTER POURING
CONCRETE SLAB
'U' BARS AS SCHEDULED ON
P/T CONTRACTORS DRAWINGS
CAST-IN 'L' BARS TOP & BTM. TO P/T
CONCTRACTORS DETAIL (PLACED INSIDE
STRESSING SLEEVES & GROUTED 56
DAYS AFTER CONCRETE POUR) PROVIDE TEMPORARY
BACK PROPPING
20 THICK POLYSTYRENE
AT BAND BEAM / WALL INTERFACE
REMOVE POLYSTYRENE AND FILL
GAP WITH GROUT 56 DAYS AFTER
POURING CONCRETE SLAB
TYPICAL TEMP. MOVEMENT JOINT 'TSJ' DETAIL
AT BEAM / WALL CONNECTION
==
CJCJ
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 20
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
WALL DETAILS
Author T.M.
P.R. R.K.
18380-S3.04
10/19/18
1 TENDER ISSUE I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
FOR CONSTRUCTION
FFL 186.500
183.5
184.
0
184.
5
185.
0
185.
5
183.8
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
50
50
C4C4
C8 C4
C4 C4
C2 C2
C5 C5 C5C5
C5 C5 C5
C1
C1
C1
C2 C2
C5C5C5C5
C5C5C5C5 C5
C2
C2
C1
C2
C1
50 50C1
C1
50
EB1
IB1
EB1
IB1
EB
1
IB1
EB
1
IB1
EB1
IB1 IB1 IB1 IB1
IB1
EB1
IB1
EB1
IB1
EB
1
EB
1
EB
2
EB1
RW
1
RW1
RW
1R
W1
DW1
DW
1
DW1
C7C7
W4
W5
W1
W2
W3
W6
W8
W12
W14
W15
W13
W16
SC
SC
SC
SC SC
SC
SC
SC SC SC
SC SC SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC SC
SC
SC SC SC
SCSCSCKJ
KJ
DJ
SC
SC
SC
DJ
SC
SC
SCSC
SCSC
SC
SCSC
SC
SC
DJ
IJ
IJ
IJ
IJ
100
50
100
50
50
100
RW1
SC
SC
RW
1
RW1
IJIJ
IJ
EB1
W7
100
SC
SC
DW
1
W4
IJ
IJ
EB1 EB1
UP
STAIR ST1 STAIR ST2
STAIR ST2
LANDING OVER
3S4.01
SLAB ON GROUND LEGEND :
DENOTES SLAB THICKNESS
DENOTES LOCAL SLAB SETDOWN
DENOTES SLAB STEPDOWN
DENOTES 2-N12 TRIMMERS TOP x 1200 LONG
DENOTES 150 SLAB ON GROUND
REINFORCE WITH SL82 MESH TOP & BTM.
ALLOW FOR VOID FORMER TYPE 'FILAVOID 75mm' UNDER SLAB
SLAB JOINTS DENOTED THUS:
DENOTED DOWELED JOINT
DENOTES SAW CUT JOINT
DENOTES ISOLATION JOINT
DJ
SC
IJ
+++
+++
+++
ALL SLABS ON GROUND SHALL BE 120 THICK PLACED ON A WATERPROOF MEMBRANE
OVER 100 COMPACTED ROAD BASE UNO.
ALL SLABS ON GROUND SHALL BE REINFORCED WITH SL82 MESH TOP UNO.
'W1 TO W17' WALLS SHALL BE 200 THICK AFS LOGICWALL. f'c = 40 MPa
ALL LANDINGS AND STAIRS THROATS 210 THK. f'c = 32 MPa
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
LEVEL 1 FLOOR PLAN
S.W. T.M.
P.R. R.K.
18380-S4.00
JULY 2018
1 PRELIMINARY ISSUE S.W. P.R. 09.08.2018
2 TENDER ISSUE S.W. P.R. 31.08.2018
3 REVISED FOR TENDER I.S. P.R. 10.10.2018
4 REVISED FOR TENDER T.L P.R. 17.10.2018
5 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SCALE 1 : 100
LEVEL 1 FLOOR PLAN
FOR CONSTRUCTION
SPECIAL PROGRAMS
LEVEL 1
SLAB EDGE
SLA
B E
DG
E
SLAB EDGE
FLOOR LEVEL
FA
CE
OF
WA
LL
8 9
200 THICK AFS REDIWALL WALLSN16-300 VERTICALN16-466 HORIZONTAL
CONCRETE STRENGTH f 'c = 32 MPa(typical)
DJ
IJ
GEOFABRICREFER NOTE 3
PROVIDE BITUMEN WATERPROOFING
TO BACK OF WALL AND JOINTSREFER NOTE 1 ON SHEET S2.02
FREE DRAINING GRANULAR BACKFILL(GRAVEL) FOR FULL HEIGHT AND
LENGTH OF RETAINING WALL
PROVIDE CORDRAIN DRAINAGE CELLFULL HEIGHT
REFER NOTE 2 ON SHEET S2.02
Ø100 AG DRAIN IN FILTERSOCK SURROUNDED
WITH GRAVEL
300
PROVIDE ONE ROW OF PROPPING TO BONDEK SLAB
600
SL92 TOP & BTM
50
N16-150 VERT.COVER 40
N16-150 VERT.COVER 40
PROVIDE BACK PROPPING TO AFS REDIWALL WALL IF BACK
FILLED PRIOR TO ABOVE SLAB HAS GAINED STRENGTH
4N20 T/BN12-300 TIES
TYPICAL FOR 400x600 RC BEAMS
1mm BONDEK
FB2
50 COVER
A
NATURAL BACKFILL MATERIALFOR TOP 300mm ONLY
GEOFABRICREFER NOTE 3
PROVIDE BITUMEN WATERPROOFINGTO BACK OF WALL AND JOINTS
REFER NOTE 1 ON SHEET S2.02
FREE DRAINING GRANULAR BACKFILL(GRAVEL) FOR FULL HEIGHT AND
LENGTH OF RETAINING WALL
PROVIDE CORDRAIN DRAINAGE CELLFULL HEIGHT
REFER NOTE 2 ON SHEET S2.02
Ø100 AG DRAIN IN FILTERSOCK SURROUNDED
WITH GRAVEL
300
200 THICK AFS REDIWALL WALLSN16-300 VERTICALN12-466 HORIZONTAL
CONCRETE STRENGTH f 'c = 32 MPa(typical)
GL
IJ
REFER S2.02 FOR DETAIL
50 COVER
2-N12 TRIMMER BARS1200 LONG
600
600
50
RE-ENTRANT CORNER - INTERNAL EDGE PENETRATION COLUMN RECESSFOR COLUMN RECESS DETAILS REFER PLAN
50
2 - N12 TRIMMER BARS(typical)
1200
50
600
600
600
600
50
50
2-N12 TRIMMER BARS(typical)
KJ
KJKJ
KJ
700 (
typica
l)
SLAB JOINTS AS NOTED ON PLAN
PLAN
INFILL SLAB AFTER ERECTIONOF TRUCTURAL STEEL
COLUMN AS NOTED
25
450
PIER AS NOTED (REFER SCHEDULE)
200
TH
ICK
NE
SS
SLA
B
(REFER PLAN)
SECTION
25
450
KJ
KJ
'T'
Y X
min
.
1/3
'T'
REFER DETAIL 'JS1'
NOTE: SAW CUT SHAL BEMADE AS SOON AS CONCRETEHAS CURED SUFFICIENTLY SO
AS NOT TO DAMAGE THE SLABSURFACE WITHIN 24 HOURSOF SLAB POUR
DEPRESS FABRIC LOCALLYBELOW SAW CUT DEPTHFOR SL82 - CUT EVERY SECOND WIRE
FOR SL72 - NOT CUTTING OF ANY WIRES(NOTE: ENSURE FABRIC LAPS DO NOT OCCUR AT JOINT)
SAW CUT JOINTNOTED 'SC' ON PLAN
NOTE:X = INDICATES CHAIR SPACING AT SAW CUT SL72 = 1000
SL82 = 1200Y = INDICATES CHAIR SPACING TYPICALLY THROUGHOUT SL72 = 600 c/c SL82 = 800 c/c
* SAW CUT LOCATIONS SHALL BE ACCURATELY MARKED OUT USING CHALK LINE* SAW CUTS SHALL BE MADE IN ONE PASS TO CORRECT DEPTH* TIME OF SAW CUT TO BE RECORDED AND LOGGED WITH BUILDER* SAW CUT ORDER SHALL COMMENCE AT 1ST CUT FROM OUTSIDE EDGE AND CONTINUE IN A ROTATIONAL ORDER TOWARDS MIDDLE OF SLAB PANEL.
REFER EXAMPLE BAYS BELOW:
4th
6th
2nd
3rd
DDJ
SC
SC
SC
DD
J
SC
SC
SC DD
J
DDJ
EXAMPLE SAW CUT SEQUENCE
1st
5th
DOWELED JOINT ISOLATION JOINT
PAINT FIRST CONCRETE FACEPOURED WITH BITUMENOUS PAINT
R20 DOWELS AT 300400 LONG LOCATED
CENTRALLY GREASEONE END
NOTED DJ ON PLAN TYPICAL AT ALL WALLS AND COLUMNS
10mm JOINTEX
TERMINATE REINFORCEMENTPOURED WITH BITUMENOUS PAINT
TOOL SLAB EDGESREFER DETAIL 'JS2'
ENSURE DOWELS AREPARALLEL - PROVIDE
N12 LACER
OR
CO
LUM
N
'T'
R10-900 TIES3L11TM BTM.
400
400
250
300
SECTION 34.00
250
300
1200N12-200 E.W -- E.F
180
RC WALL
3 INITIAL SAW CUT
6
20
AS
NO
TE
D
SA
W C
UT
DOW CORNING 888 SILICONEJOINT SEALANT OR
APPROVED EQUIVALENT
Ø8 CLOSED CELL EXPANDEDPOLYETHYLENE FOAM BACKING ROD
NOTE:SEALANT SHALL BE PLACED
MINIMUM 4 WEEKS AFTER PUORING OF SLAB
TYPICAL SAW CUT JOINTSEALANT DETAIL 'JS1'
25
10
EDGE OF POUR TO BEBITUMEN PAINTED
DOW CORNIING 888 SILICONEJOITNT SEALANT OR
APPROVED EQUIVALENT
Ø12 CLOSED CELL EXPANDEDPOLYETHYLENE FOAM BACKING ROD
NOTE:SEALANT SHALL BE PLACED
MINIMUM 4 WEEKS AFFTERPUORING F SLAB
TYPICAL CONTINUOUS POUR DOWELEDJOINT DETAIL 'JS2'
MAXIMUM DOWEL JOINT SPACING 25m. NOTIFY ENGINEER IF JOINT SPACING EXCEEDS 25m
This drawing and design remains the propery of Henry & Hymas and may not becopied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
LEVEL 1 DETAILS
S.W. T.M.
P.R. R.K.
18380-S4.01
JULY 2018
1 TENDER ISSUE S.W. P.R. 31.08.2018
2 REVISED FOR TENDER I.S. P.R. 10.10.2018
3 REVISED FOR TENDER T.L P.R. 17.10.2018
4 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SECTIONSCALE 1 : 20 S2.00
1
SECTIONSCALE 1 : 20
2
FOR CONSTRUCTION
SCALE 1 : 50
TYPICAL TRIMMING DETAILS
SCALE 1 : 20
TYPICAL SLAB ON GROUND BLOCK-OUT AT COLUMN
SCALE 1 : 20
EDGE BEAM 'EB1' DETAIL
SCALE 1 : 20
INTERNAL BEAM 'IB1' DETAIL
S2.00
DENOTES STEP IN SLAB
DENOTES LOCAL SLAB SETDOWN
DENOTES SLAB THICKNESS
SUSPENDED CONCRETE LEGEND:
DENOTES LOAD BEARING WALL/COLUMN UNDER
DENOTES NON-LOAD BEARING WALL OVER
DENOTES REINFORCED CONCRETE WALL/COLUMN
OVER
DENOTES REINFORCED CONCRETE WALL/COLUMN
UNDER & OVER
DENOTES COLUMN OVER TYPE
REFER DRAWING SERIES S4.00 FOR DETAILS
DENOTES COLUMN UNDER TYPE
REFER DRAWING SERIES S4.00 FOR DETAILS
HOB DENOTES HOB. REFER ARCHITECT'S DRAWINGS
FOR LOCATIONS & SIZES
DENOTES WIDTH OF CONCRETE UPSTAND
REFER ARCHITECTURAL CONCRETE SETOUT DRAWINGS FOR
DETAILS+++ UPSTAND
C+
C+
+++
+++
+++
POST-TENSIONED SLAB AND BEAM CONSTRUCTION FLOOR DESIGN PARAMETERS
DESIGN LOADING: LIVE LOAD REDUCTIONS SHALL NOT BE USED
LIVE LOADS GENERALLY:-
BALCONY/ STAIRS-
LIBRARY-
GENERALLY-SUPERIMPOSED DEAD LOAD
DENOTES DEAD LOAD OF ++kN-POINT LOADS - DL++
-- LL++
CONCRETE STRENGTH:
DENOTES LIVE LOAD OF ++kN
3.0 kPa
1.0 kPa
UNLESS NOTED OTHERWISE MINIMUM CONCRETE STRENGTH SHALL BE:
f'c = 40 MPa
FIRE RATING:
DEFLECTION LIMITATION:
UNLESS NOTED OTHERWISE FIRE RATING SHALL BE: 2 HOURS
TOTAL DEFLECTION: L/250 OR 25mm (typical UNO)
L/125 (CANTILEVER)
INCREMENTAL DEFLECTION: L/500
L/1000 (AT MASONRY WALLS
GENERALLY-
COVER:
INTERNAL: 25mm
EXPOSED SURFACES: 40mm
PROVIDE PLASTIC OR CONCRETE BAR
CHAIRS TO ALL EXPOSED SURFACES.
NOTE:
1. THE MINIMUM CONCRETE STRENGTH AS NOTED MAY BE INCREASED BY THE POST TENSIONING
DESIGNER TO FACILITATE THE STRESSING PROGRAM.
2. THE POST TENSIONING CONTRCTOR SHALL DESIGN AND DOCUMENTS ALL ELEMENTS CAST
INTEGRALLY WITH THE POST TENSIONED FLOOR INCLUDING ALL EDGE BEAMS.
3. STRUCTURAL SIZES AND FRAMING AS INDICATED ON PLAN ARE INDICATIVE ONLY, THE POST
TENSIONING CONTRACTOR MAY VARY THE INDICATED SIZES AS REQUIRED TO COMPLY WITH
AUSTRALIAN STANDARDS OR TO PRODUCE A MORE ECONOMICAL DESIGN.
4. FOR CO-ORDINATION PURPOSES, ANY VARIATIONS TO THIS PLAN/DESIGN MADE BY THE POST
TENSIONING CONTRACTOR SHALL BE APPROVED BY HENRY AND HYMAS.
BALCONY- 1.5 kPa
4.0 kPa
7.0 kPa
DENOTES DEAD LOAD OF ++kN/m-LINE LOADS - DL/m++
-- LL/m++ DENOTES LIVE LOAD OF ++kN/m
ROOF PLANT- 2.0 kPa
ROOF PLANT- 5.0 kPa
THIS DRAWING SHALL BE USED FOR FORMWORK PURPOSES
ONLY AND SHALL BE READ IN CONJUNCTION WITH THE
POST TENSIONING CONTRACTORS DRAWINGS.
ANY DISCREPANCIES FOUND IN THE SIZING OF CONCRETE
ELEMENTS ON THE DRAWING SHALL BE FORWARDED TO
THE ENGINEER PRIOR TO ERECTING THE FORMWORK.
NOTES :
SLAB ON GROUND LEGEND :
DENOTES SLAB THICKNESS
DENOTES LOCAL SLAB SETDOWN
DENOTES SLAB STEPDOWN
DENOTES 2-N12 TRIMMERS TOP x 1200 LONG
DENOTES 150 SLAB ON GROUND
REINFORCE WITH SL82 MESH TOP & BTM.
POURED OVER VOID FORMER TYPE 'FILAVOID 75mm' UNDER SLAB
DENOTES 170 THICK SLAB POURED ON 1.0 BMT BONDEK
DJ
SC
IJ+++
+++
+++
SLAB JOINTS DENOTED THUS:
DENOTED DOWELED JOINT
DENOTES SAW CUT JOINT
DENOTES ISOLATION JOINT
ALL SLABS ON GROUND SHALL BE 120 THICK PLACED ON A WATERPROOF MEMBRANE
OVER 100 COMPACTED ROAD BASE UNO.
ALL SLABS ON GROUND SHALL BE REINFORCED WITH SL82 MESH TOP UNO.
'W1 TO W17' WALLS SHALL BE 200 THICK AFS LOGICWALL. f'c = 40 MPa
ALL LANDINGS AND STAIRS THROATS 210 THK. f'c = 32 MPa
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
1S4.01
2S4.01
280
x 60
0 P
/T
BA
ND
BE
AM
280 x 600 P/T
BAND BEAM
280 x 600 P/T BAND BEAM280 x 600 P/T BAND BEAM
280
x 60
0 P
/T
BA
ND
BE
AM
280
x 60
0 P
/T
BA
ND
BE
AM
230 x 600 P/T
BAND BEAM
280
x 60
0 P
/T B
AN
D B
EA
M
280 x 600 P/T BAND BEAM
280
x 60
0 P
/T B
AN
D B
EA
M
280
x 80
0 P
/T
BA
ND
BE
AM
280 x 600 P/T
BAND BEAM
50
50
260
C2C2C2
C4 C4
C4 C4
C4
C2
C4 C4
C2 C2 C2 C2
C2 C2
C4
C5 C5 C5 C5
C5C5 C5
C2
C2
C2
C2 C2
C2
C2
C2C2C2
C5 C5 C5 C5
50
C1
C1
C1
SYMBOL DENOTES
SPAN DIRECTION
OF 1.0 BMT BONDEK
C2
C1
C1
C1
C1
IB1
EB1
EB1
IB1
EB
1
IB1
EB
1
IB1
EB1
C7 C7
W1
W3
W2
W12
W4
W5
W14
W15
W13
W16
W6
W8
W10(U)
W11
C2
C2CB1
C2
PT
210
150
150
150150
150
150
SOG
SOG
SOG SOG
SOG
SOG
RW
1
SC
SC
SCSC
SC
SC
SC
SC
400
x 60
0 R
C B
EA
M
210
210
C2
PROVIDE TEMP. PROPPING
TO SLAB UNTIL
DOWELS ARE GROUTED.
EB
1
DW1(u)
DW
1(u)
DJ
SCSC
SC
UP
230
x 60
0 P
/T
BA
ND
BE
AM
280
x 60
0 P
/T
BA
ND
BE
AM
CONCRETE DOWNTURN
CB3 CB3
C2
3S5.01
210
LANDING ABOVE
DW
1(u)
C5
UP
UP
UP
UP
UP
280
x 80
0 P
/T
BA
ND
BE
AM
400 x 1200 P/T
BAND BEAM
PROVIDE TEMP. PROPPING
TO SLAB UNTIL
DOWELS ARE GROUTED.
EB1
STAIR ST1 STAIR ST2 STAIR ST3
STAIR ST4
STAIR ST5
1S5.01
4S5.01
2S5.01
TMJ
TM
J
W4a
TMJ
TMJ
TM
J
5S5.01
W7
VOID
7S5.01
CB2HATCHING DENOTES THE
EXTENT OF THE LIBRARY
B
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
BNBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
LEVEL 2 FLOOR PLAN
S.W. T.M.
P.R. R.K.
18380-S5.00
JULY 2018
1 PRELIMINARY ISSUE S.W. P.R. 09.08.2018
2 TENDER ISSUE S.W. P.R. 31.08.2018
3 REVISED FOR TENDER I.S. P.R. 10.10.2018
4 REVISED FOR TENDER T.L P.R. 17.10.2018
5 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
B REVISED FOR CONSTRUCTION I.S. P.R. 30.01.2019
FOR CONSTRUCTION
ALL SUSPENDED SLABS SHALL BE 210 THICK UNO.
SCALE 1 : 100
LEVEL 2 FLOOR PLAN
HEADER BEAM MEMBER SCHEDULE
MEMBER TAG MEMBER SIZE
DL 150 PFC
H
HB
65 x 65 x 3 SHS
50 x 50 x 3 SHS
MEMBER SIZE
REFER TO OPERABLE WALL FIXING DETAILS ON SHEET S9.03
REFER TO OPERABLE WALL FIXING DETAILS ON SHEET S9.03
REFER TO OPERABLE WALL FIXING DETAILS ON SHEET S9.03
B
LEVEL 2
280
600
3N24 TOP
3N28 BTM
N12-300 TIES
450
400
340
600
4N28 TOP
4N24 BTM
R10-300 TIES
STAIRS AS DETAILED
RC SLAB AS DETAILED
WALL BEHIND
CB1 DETAIL CB2 DETAIL
LEVEL 2
230
600600
260
50
340
4N28 TOP
4N24 BTM
R10-300 TIES
STAIRS AS DETAILED
RC SLAB AS DETAILED
CB1 DETAIL
LEVEL 2
1200
400
600
490
C2 COLUMN AS DETAILED
RC BEAM AS DETAILED
600
300
4N28
4N24
450
400
3N24 TOP
3N28 BTM
N12-300 TIES
STAIRS AS DETAILED
RC SLAB AS DETAILED
CB3 DETAIL
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 20
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
LEVEL 2 DETAILS
Author T.M.
P.R. R.K.
18380-S5.01
01/21/19
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SECTIONSCALE 1 : 20 S5.00
3SECTIONSCALE 1 : 20 S5.00
1
SECTIONSCALE 1 : 20 S5.00
4
SECTIONSCALE 1 : 20 S5.00
2
FOR CONSTRUCTION
SECTIONSCALE 1 : 20 S5.00
5 SECTIONSCALE 1 : 20 S6.00
6
SECTIONSCALE 1 : 20 S5.00
7
DENOTES STEP IN SLAB
DENOTES LOCAL SLAB SETDOWN
DENOTES SLAB THICKNESS
SUSPENDED CONCRETE LEGEND:
DENOTES LOAD BEARING WALL/COLUMN UNDER
DENOTES NON-LOAD BEARING WALL OVER
DENOTES REINFORCED CONCRETE WALL/COLUMN
OVER
DENOTES REINFORCED CONCRETE WALL/COLUMN
UNDER & OVER
DENOTES COLUMN OVER TYPE
REFER DRAWING SERIES S4.00 FOR DETAILS
DENOTES COLUMN UNDER TYPE
REFER DRAWING SERIES S4.00 FOR DETAILS
HOB DENOTES HOB. REFER ARCHITECT'S DRAWINGS
FOR LOCATIONS & SIZES
DENOTES WIDTH OF CONCRETE UPSTAND
REFER ARCHITECTURAL CONCRETE SETOUT DRAWINGS FOR
DETAILS+++ UPSTAND
C+
C+
+++
+++
+++
POST-TENSIONED SLAB AND BEAM CONSTRUCTION FLOOR DESIGN PARAMETERS
DESIGN LOADING: LIVE LOAD REDUCTIONS SHALL NOT BE USED
LIVE LOADS GENERALLY:-
BALCONY/ STAIRS-
LIBRARY-
GENERALLY-SUPERIMPOSED DEAD LOAD
DENOTES DEAD LOAD OF ++kN-POINT LOADS - DL++
-- LL++
CONCRETE STRENGTH:
DENOTES LIVE LOAD OF ++kN
3.0 kPa
1.0 kPa
UNLESS NOTED OTHERWISE MINIMUM CONCRETE STRENGTH SHALL BE:
f'c = 40 MPa
FIRE RATING:
DEFLECTION LIMITATION:
UNLESS NOTED OTHERWISE FIRE RATING SHALL BE: 2 HOURS
TOTAL DEFLECTION: L/250 OR 25mm (typical UNO)
L/125 (CANTILEVER)
INCREMENTAL DEFLECTION: L/500
L/1000 (AT MASONRY WALLS
GENERALLY-
COVER:
INTERNAL: 25mm
EXPOSED SURFACES: 40mm
PROVIDE PLASTIC OR CONCRETE BAR
CHAIRS TO ALL EXPOSED SURFACES.
NOTE:
1. THE MINIMUM CONCRETE STRENGTH AS NOTED MAY BE INCREASED BY THE POST TENSIONING
DESIGNER TO FACILITATE THE STRESSING PROGRAM.
2. THE POST TENSIONING CONTRCTOR SHALL DESIGN AND DOCUMENTS ALL ELEMENTS CAST
INTEGRALLY WITH THE POST TENSIONED FLOOR INCLUDING ALL EDGE BEAMS.
3. STRUCTURAL SIZES AND FRAMING AS INDICATED ON PLAN ARE INDICATIVE ONLY, THE POST
TENSIONING CONTRACTOR MAY VARY THE INDICATED SIZES AS REQUIRED TO COMPLY WITH
AUSTRALIAN STANDARDS OR TO PRODUCE A MORE ECONOMICAL DESIGN.
4. FOR CO-ORDINATION PURPOSES, ANY VARIATIONS TO THIS PLAN/DESIGN MADE BY THE POST
TENSIONING CONTRACTOR SHALL BE APPROVED BY HENRY AND HYMAS.
BALCONY- 1.5 kPa
4.0 kPa
7.0 kPa
DENOTES DEAD LOAD OF ++kN/m-LINE LOADS - DL/m++
-- LL/m++ DENOTES LIVE LOAD OF ++kN/m
ROOF PLANT- 2.0 kPa
ROOF PLANT- 5.0 kPa
THIS DRAWING SHALL BE USED FOR FORMWORK PURPOSES
ONLY AND SHALL BE READ IN CONJUNCTION WITH THE
POST TENSIONING CONTRACTORS DRAWINGS.
ANY DISCREPANCIES FOUND IN THE SIZING OF CONCRETE
ELEMENTS ON THE DRAWING SHALL BE FORWARDED TO
THE ENGINEER PRIOR TO ERECTING THE FORMWORK.
NOTES :
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
1200 x 2100 P/T BAND BEAM
1200 x 1800 P/T BAND BEAM
1200 x 2100 P/T BAND BEAM
280 x 600 P/T BAND BEAM 280 x 600 P/T BAND BEAM
280 x 600 P/T BAND BEAM 280 x 600 P/T BAND BEAM
280
x 60
0 P
/T B
AN
D B
EA
M
280
x 60
0 P
/T B
AN
D B
EA
M
280
x 60
0 P
/T B
AN
D B
EA
M
280
x 60
0 P
/T B
AN
D B
EA
M
280 x 600 P/T BAND BEAM
280
x 60
0 P
/T
BA
ND
BE
AM
280
x 80
0 P
/T
BA
ND
BE
AM
280 x 600 P/T BAND BEAM
260
280 x 600 P/T
BAND BEAM
50
50
C4
C4
C4 C4
C4
C4 C4
C2 C2
C2
C2 C2 C2 C2 C2 C2 C2 C2
C2
C4 C4
C4C4
C4 C4
C2 C2
C4
C5 C5 C5 C5
C2 C5
C1
C2
C2
C2 C2
C2
C4
C4
C2
C2
C2C2
C4
C2
C1
C1
50
C4C4
C1
230 x 600 P/T
BAND BEAM
450
x 15
00 P
/T B
AN
D B
EA
M
C1
C1
C1
1200
x 8
00
P/T
BA
ND
BE
AM
C7 C7
W1
W2
W3
W12
W4
W5
W8
W14
W15
W13
W16
W11
C2
450 x 400 RC BEAM
210
210
C2
1S6.01
CB3 CB3 CB3
210C4
C2
C2
UP
UP
UP
400 x 1200 P/T
BAND BEAM
280
x 80
0 P
/T
BA
ND
BE
AM
PROVIDE TEMP. PROPPING
TO SLAB UNTIL
DOWELS ARE GROUTED.
PROVIDE TEMP. PROPPING
TO SLAB UNTIL
DOWELS ARE GROUTED.
CJ
CJ
CJ
CJ
CJ
POUR 1
POUR 2
20
STAIR ST1 STAIR ST2 STAIR ST3
STAIR ST4
3N24 TOP
3N28 BTM
N12-300 TIES
TYPICAL FOR
450x400 RC BEAMS
ST
AIR
ST
7
DL
HB
HB
HB
HH
H
DLH H
HB
HB
HB
HH
DL
HB
HB
HB
HDL
HB
H
DL
HB
HB
DLH H
HB
HB HH
DL
HB
DL HH
HB
HB
HH
DL
HB
HBHH
H
HB
H
DL
HB
HB
HH
DL
HB
HHB
HH
DL
HB
DL
HB
HB
DLH H
HB
HB
HH
DL
HB
DL HH
HB
HBHH
DL
HB
HBHH
H
DL
HB
HB
HB
HH
H
HB HB
HB HB
HB
HB
HB
H H HDL
HB
H
W4a
200
MIN.
FA LL
FALL
2S6.01
3S6.01
4S6.01
5S6.01
7S6.01
6S5.01
TMJ
TM
J
TMJ
TM
J
TMJ
TM
J
TMJ
2S5.01
1S5.01
8S6.01
W7
CJ
EXTENT OF RC SLAB
TM
J
TM
JT
MJ
210
210
DL = 420
LL = 190DL = 420
LL = 190
DL = 390
LL = 190DL = 330
LL = 150
DL = 420
LL = 260DL = 340
LL = 210
DL = 540
LL = 240
CB1
CB2
B
HATCHING DENOTES THE
EXTENT OF THE LIBRARY
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
BNBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
LEVEL 3 FLOOR PLAN
S.W. T.M.
P.R. R.K.
18380-S6.00
JULY 2018
1 PRELIMINARY ISSUE S.W. P.R. 09.08.2018
2 TENDER ISSUE S.W. P.R. 31.08.2018
3 REVISED FOR TENDER I.S. P.R. 10.10.2018
4 REVISED FOR TENDER T.L P.R. 17.10.2018
5 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
B REVISED FOR CONSTRUCTION I.S. P.R. 30.01.2019
FOR CONSTRUCTION
ALL POST-TENSIONED SLABS SHALL BE 210 THICK UNO.
'W1 TO W17' WALLS SHALL BE 200 THICK AFS LOGICWALL, f'c = 40 MPa
ALL LANDINGS AND STAIRS THROATS 210 THK, f'c = 32 MPa
SCALE 1 : 100
LEVEL 3 FLOOR PLAN
HEADER BEAM MEMBER SCHEDULE
MEMBER TAG MEMBER SIZE
DL 150 PFC
H
HB
65 x 65 x 3 SHS
50 x 50 x 3 SHS
DL = XX
DX = XXDENOTES TRANSFER LOADS FOR PT DESIGN
CJDENOTES TIED CONSTRUCTION JOINTS
REFER DETAIN ON SHEET S6.01
B
LEVEL 3
280
200
20
600
CJ
DRIP GROOVE
PROVIDE COVER TO BARS
TYPICAL
2N12
R10-300 TIES
20020 CHAMFER
TYPICAL
FALLLEVEL 3
600
280
COLUMN BEYOND
LEVEL 3
230
600
OPENING
LEVEL 3
260
600
50
LEVEL 3
400
1200
LEVEL 3
1800
1200
C1COLUMN AS DETAILED
TYPICAL PT SLAB CONTROL JOINT 'CJ' DETAIL
RE
FE
R P
LAN
CJ
N12 -200 TOP AND BOTTOM - POSITION
BOTTOM BARS IN 2ND LAYER TO ALLOW
STAIR BOTTOM REO TO BE LAID FIRST
LAP
600
LAP
600
POUR 1 POUR 2
SCABLE FACE OF FIRST
POUR AND APPLY
BONDING AGENT.
LEVEL 3
450
1500
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 20
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
LEVEL 3 DETAILS
Author T.M.
P.R. R.K.
18380-S6.01
01/21/19
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SECTIONSCALE 1 : 20 S6.00
1 SECTIONSCALE 1 : 20 S6.00
2 SECTIONSCALE 1 : 20 S6.00
3 SECTIONSCALE 1 : 20 S6.00
4
SECTIONSCALE 1 : 20 S6.00
5
FOR CONSTRUCTION
SECTIONSCALE 1 : 20 S6.00
7
SECTIONSCALE 1 : 20 S6.00
8
DENOTES STEP IN SLAB
DENOTES LOCAL SLAB SETDOWN
DENOTES SLAB THICKNESS
SUSPENDED CONCRETE LEGEND:
DENOTES LOAD BEARING WALL/COLUMN UNDER
DENOTES NON-LOAD BEARING WALL OVER
DENOTES REINFORCED CONCRETE WALL/COLUMN
OVER
DENOTES REINFORCED CONCRETE WALL/COLUMN
UNDER & OVER
DENOTES COLUMN OVER TYPE
REFER DRAWING SERIES S4.00 FOR DETAILS
DENOTES COLUMN UNDER TYPE
REFER DRAWING SERIES S4.00 FOR DETAILS
HOB DENOTES HOB. REFER ARCHITECT'S DRAWINGS
FOR LOCATIONS & SIZES
DENOTES WIDTH OF CONCRETE UPSTAND
REFER ARCHITECTURAL CONCRETE SETOUT DRAWINGS FOR
DETAILS+++ UPSTAND
C+
C+
+++
+++
+++
THIS DRAWING SHALL BE USED FOR FORMWORK PURPOSES
ONLY AND SHALL BE READ IN CONJUNCTION WITH THE
POST TENSIONING CONTRACTORS DRAWINGS.
ANY DISCREPANCIES FOUND IN THE SIZING OF CONCRETE
ELEMENTS ON THE DRAWING SHALL BE FORWARDED TO
THE ENGINEER PRIOR TO ERECTING THE FORMWORK.
NOTES :
POST-TENSIONED SLAB AND BEAM CONSTRUCTION FLOOR DESIGN PARAMETERS
DESIGN LOADING: LIVE LOAD REDUCTIONS SHALL NOT BE USED
LIVE LOADS GENERALLY:-
BALCONY/ STAIRS-
LIBRARY-
GENERALLY-SUPERIMPOSED DEAD LOAD
DENOTES DEAD LOAD OF ++kN-POINT LOADS - DL++
-- LL++
CONCRETE STRENGTH:
DENOTES LIVE LOAD OF ++kN
3.0 kPa
1.0 kPa
UNLESS NOTED OTHERWISE MINIMUM CONCRETE STRENGTH SHALL BE:
f'c = 40 MPa
FIRE RATING:
DEFLECTION LIMITATION:
UNLESS NOTED OTHERWISE FIRE RATING SHALL BE: 2 HOURS
TOTAL DEFLECTION: L/250 OR 25mm (typical UNO)
L/125 (CANTILEVER)
INCREMENTAL DEFLECTION: L/500
L/1000 (AT MASONRY WALLS
GENERALLY-
COVER:
INTERNAL: 25mm
EXPOSED SURFACES: 40mm
PROVIDE PLASTIC OR CONCRETE BAR
CHAIRS TO ALL EXPOSED SURFACES.
NOTE:
1. THE MINIMUM CONCRETE STRENGTH AS NOTED MAY BE INCREASED BY THE POST TENSIONING
DESIGNER TO FACILITATE THE STRESSING PROGRAM.
2. THE POST TENSIONING CONTRCTOR SHALL DESIGN AND DOCUMENTS ALL ELEMENTS CAST
INTEGRALLY WITH THE POST TENSIONED FLOOR INCLUDING ALL EDGE BEAMS.
3. STRUCTURAL SIZES AND FRAMING AS INDICATED ON PLAN ARE INDICATIVE ONLY, THE POST
TENSIONING CONTRACTOR MAY VARY THE INDICATED SIZES AS REQUIRED TO COMPLY WITH
AUSTRALIAN STANDARDS OR TO PRODUCE A MORE ECONOMICAL DESIGN.
4. FOR CO-ORDINATION PURPOSES, ANY VARIATIONS TO THIS PLAN/DESIGN MADE BY THE POST
TENSIONING CONTRACTOR SHALL BE APPROVED BY HENRY AND HYMAS.
BALCONY- 1.5 kPa
4.0 kPa
7.0 kPa
DENOTES DEAD LOAD OF ++kN/m-LINE LOADS - DL/m++
-- LL/m++ DENOTES LIVE LOAD OF ++kN/m
ROOF PLANT- 2.0 kPa
ROOF PLANT- 5.0 kPa
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
280 x 600 P/T BAND BEAM
280
x 60
0 P
/T B
AN
D B
EA
M
280
x 60
0 P
/T B
AN
D B
EA
M
280
x 60
0 P
/T B
AN
D B
EA
M
280 x 600 P/T BAND BEAM
280
x 60
0 P
/T B
AN
D B
EA
M
280 x 600 P/T BAND BEAM 280 x 600 P/T BAND BEAM 280 x 600 P/T BAND BEAM
280 x 600 P/T BAND BEAM
280 x 700 P/T BAND BEAM280
x 80
0 P
/T
BA
ND
BE
AM
280
x 60
0 P
/T
BA
ND
BE
AM
50
50C4 C4
C4 C4
C4
C2
C2
C2 C2
C2
C2
C2 C2
C2 C2 C2 C2
C2 C2
C4 C4
C2
C4
C4
C2 C2
C2
C2
C2 C2C2 C2
C4
C4
REFER SHEET S9.01
FOR STAIR FRAMING
DETAILS
260
50
C4C4
C4
C4
C4 C4
C7
W1
W4
W5
W14
W15
W13
W16
W11
C2
210
210
C7
C4
C4
CJ
CJ
CJ
CJ
CJ
POUR 1
POUR 2
20
W12
W2
W3
W6
W8
PROVIDE TEMP. PROPPING
TO SLAB UNTIL
DOWELS ARE GROUTED.
CB3CB3CB3
230 x 600 P/T
BAND BEAM
C4
200MIN.
FA LL
FALL
200 MIN.
FA LL
FALL
C2
UP
UP
450 x 400 RC BEAM
400 x 1200 P/T
BAND BEAM
DL
HB
HB
HB
HH
H
DLH H
HB
HB
HB
HH
DL
HB
HB
HB
HDL
HB
H
DL
HB
HB
DLH H
HB
HB HH
DL
HB
DL HH
HB
HB
HH
DL
HB
HBHH
H
HB
H
DL
HB
HB
HH
DL
HB
H
DL
HB
HB
HBHH
H
H
HB HH
DL
HB
DL
HB
HB
HBHH
H
HB
HB
HH
DL
HB
DL
HB
HB
DLH H
HB
HB
HH
DL
HB
DL HH
HB
HBHH
DL
HB
HBHH
H
DL
HB
HB
HB
HH
H
DL
HB
HB
HB
HH
H
DLH H
HB
HB
HB
HH
DL
HB
HB
HB
HDL
HB
H
DL
HB
HB
DLH H
HB
HB HH
DL
HB
DL HH
HB
HB
HH
DL
HB
HBHH
H
HB
H
DL
HB
HB
HH
DL
HB
HHB
HH
DL
HB
DL
HB
HB
DLH H
HB
HB
HH
DL
HB
DL HH
HB
HBHH
DL
HB
HBHH
H
DL
HB
HB
HB
HH
H
HHB
HH
DL
HB
HB
H
HB HH
DL
HB
HB H
HB
HH
DL
HB
HB
PROVIDE TEMP. PROPPING
TO SLAB UNTIL
DOWELS ARE GROUTED.
PROVIDE TEMP. PROPPING
TO SLAB UNTIL
DOWELS ARE GROUTED.
STAIR ST1 STAIR ST2 STAIR ST3
STAIR ST4
HB HB
HB HB
HB HB
HB HB
280
x 70
0 P
/T
BA
ND
BE
AM
6S5.01
1S5.01
2S5.01
TM
J
TMJ
TM
JT
MJ
TMJ
TM
J
TMJ
TM
J
3S6.01
SIM
5S6.01
SIM
2S6.01
SIM
4S6.01
SIM
W4aTMJ
TM
J
210
210
CB2
CB1
HATCHING DENOTES THE
EXTENT OF THE LIBRARY
B
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
BNBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
LEVEL 4 FLOOR PLAN
S.W. T.M.
P.R. R.K.
18380-S7.00
JULY 2018
1 PRELIMINARY ISSUE S.W. P.R. 09.08.2018
2 TENDER ISSUE S.W. P.R. 31.08.2018
3 REVISED FOR TENDER I.S. P.R. 10.10.2018
4 REVISED FOR TENDER T.L P.R. 17.10.2018
5 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
B REVISED FOR CONSTRUCTION I.S. P.R. 30.01.2019
FOR CONSTRUCTION
ALL POST-TENSIONED SLABS SHALL BE 210 THICK UNO.
'W1 TO W17' WALLS SHALL BE 200 THICK AFS LOGICWALL. f'c = 40 MPa
ALL LANDINGS AND STAIRS THROATS 210 THK, f'c = 32 MPa
SCALE 1 : 100
LEVEL 4 FLOOR PLAN
B
THIS DRAWING SHALL BE USED FOR FORMWORK PURPOSES
ONLY AND SHALL BE READ IN CONJUNCTION WITH THE
POST TENSIONING CONTRACTORS DRAWINGS.
ANY DISCREPANCIES FOUND IN THE SIZING OF CONCRETE
ELEMENTS ON THE DRAWING SHALL BE FORWARDED TO
THE ENGINEER PRIOR TO ERECTING THE FORMWORK.
NOTES :
POST-TENSIONED SLAB AND BEAM CONSTRUCTION FLOOR DESIGN PARAMETERS
DESIGN LOADING: LIVE LOAD REDUCTIONS SHALL NOT BE USED
LIVE LOADS GENERALLY:-
BALCONY/ STAIRS-
ROOF PLANT-
GENERALLY-SUPERIMPOSED DEAD LOAD
DENOTES DEAD LOAD OF ++kN-POINT LOADS - DL++
-- LL++
CONCRETE STRENGTH:
DENOTES LIVE LOAD OF ++kN
3.0 kPa
1.0 kPa
UNLESS NOTED OTHERWISE MINIMUM CONCRETE STRENGTH SHALL BE:
f'c = 40 MPa
FIRE RATING:
DEFLECTION LIMITATION:
UNLESS NOTED OTHERWISE FIRE RATING SHALL BE: 2 HOURS
TOTAL DEFLECTION: L/250 OR 25mm (typical UNO)
L/125 (CANTILEVER)
INCREMENTAL DEFLECTION: L/500
L/1000 (AT MASONRY WALLS
GENERALLY-
COVER:
INTERNAL: 25mm
EXPOSED SURFACES: 40mm
PROVIDE PLASTIC OR CONCRETE BAR
CHAIRS TO ALL EXPOSED SURFACES.
NOTE:
1. THE MINIMUM CONCRETE STRENGTH AS NOTED MAY BE INCREASED BY THE POST TENSIONING
DESIGNER TO FACILITATE THE STRESSING PROGRAM.
2. THE POST TENSIONING CONTRCTOR SHALL DESIGN AND DOCUMENTS ALL ELEMENTS CAST
INTEGRALLY WITH THE POST TENSIONED FLOOR INCLUDING ALL EDGE BEAMS.
3. STRUCTURAL SIZES AND FRAMING AS INDICATED ON PLAN ARE INDICATIVE ONLY, THE POST
TENSIONING CONTRACTOR MAY VARY THE INDICATED SIZES AS REQUIRED TO COMPLY WITH
AUSTRALIAN STANDARDS OR TO PRODUCE A MORE ECONOMICAL DESIGN.
4. FOR CO-ORDINATION PURPOSES, ANY VARIATIONS TO THIS PLAN/DESIGN MADE BY THE POST
TENSIONING CONTRACTOR SHALL BE APPROVED BY HENRY AND HYMAS.
BALCONY- 1.5 kPa
4.0 kPa
5.0 kPa
DENOTES DEAD LOAD OF ++kN/m-LINE LOADS - DL/m++
-- LL/m++ DENOTES LIVE LOAD OF ++kN/m
ROOF PLANT- 2.0 kPaDENOTES STEP IN SLAB
DENOTES LOCAL SLAB SETDOWN
DENOTES SLAB THICKNESS
SUSPENDED CONCRETE LEGEND:
DENOTES LOAD BEARING WALL/COLUMN UNDER
DENOTES NON-LOAD BEARING WALL OVER
DENOTES REINFORCED CONCRETE WALL/COLUMN
OVER
DENOTES REINFORCED CONCRETE WALL/COLUMN
UNDER & OVER
DENOTES COLUMN OVER TYPE
REFER DRAWING SERIES S4.00 FOR DETAILS
DENOTES COLUMN UNDER TYPE
REFER DRAWING SERIES S4.00 FOR DETAILS
HOB DENOTES HOB. REFER ARCHITECT'S DRAWINGS
FOR LOCATIONS & SIZES
DENOTES WIDTH OF CONCRETE UPSTAND
REFER ARCHITECTURAL CONCRETE SETOUT DRAWINGS FOR
DETAILS+++ UPSTAND
C+
C+
+++
+++
+++
ROOF
200 THK REDIWALL
N16 - 300 VERTICAL
N12 - 466 HORIZONTAL
CENTRAL TYPICAL
2000
280
ROOF
200
1N12
R10-300 'L' BARS
TYPICAL HOB DETAIL
150
CJ
1 2 3 4 5 6 7 8 9
A
B
C
D
E
C4 C4
C4
C2
C2C4
C4
C4
400
x 12
00 P
/T
BA
ND
BE
AM
200 REDIWALL 200 REDIWALL
200 REDIWALL
200 REDIWALL
200
RE
DIW
ALL
200
RE
DIW
ALL
200
RE
DIW
ALL
C7
W4
W5
MIN.
210
SLAB FALLS TO HYDRAULIC
ENGINEER'S DETAILS
W1
W2
W3
W6
W8
280 x 600 P/T
BAND BEAM
280 x 600 P/T
BAND BEAM
280
x200
0 P
/T B
AN
D B
EA
M
200
RE
DIW
ALL
2S8.00
W14
W13
W16
W15
C7
UP
400
x 12
00 P
/T
BA
ND
BE
AM
HOB
HO
B
HO
B
C7C7
1
W12
W4a
MIN
.
1000
5S8.00
HOB
HOB
HO
B
HO
B
RWO RWO
E
ROOF
600
280
1000 MIN.
ROOF
1200
400
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
ROOF FLOOR PLAN
S.W. T.M.
P.R. R.K.
18380-S8.00
JULY 2018
1 TENDER ISSUE S.W. P.R. 31.08.2018
2 REVISED FOR TENDER I.S. P.R. 10.10.2018
3 REVISED FOR TENDER T.L P.R. 17.10.2018
4 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
ALL POST-TENSIONED SLABS SHALL BE 210 MIN. THICK UNO.
FOR CONSTRUCTION
SECTION-SCALE 1 : 20
1
SCALE 1 : 100
ROOF PLAN
SECTION-SCALE 1 : 20
2
ELEVATION-SCALE 1 : 20
5
1 2 3 4 5 6 7 8 910 11
A
B
C
D
E
F
R3
P2
R2
R2
R3
R3
R3 R2
SC2
SC2
R2
R2
SC2
SC2
SC2
SC2
SC2
SC2
ST1
R1
SC2 SC2
R2 R1
R1
R1
SC2
SC2
SC2 SC2
SC2 SC2
ST1
SC2
SC2
SC2
SC2
B1
ST1
B1 ST1
ST1
B1
SC2
SC2
SC2
SC2
B1
SC2
SC2
R1
SC2
B2(
U)
SC2
SC2
P2
P2
P2
P2
P2
P2
P2
P2 P2 P2
P2
P2 P2 P2
P2 P2
ST1
P2
SC2
SC2
P2
P2
P2 P2
P2
P2 P2
R2
R1
R1
RA
1
R1
RA
1
R1
R1
R1
BR
BR
BR
B1
P1
P1
P1
P1
P1
P1
P1
P1
SC2
P2
P2
P2 P2 P2
R1
R1
SC2
B1(
U)
R3
BR
B1
BR
BR
BR
BR BR
BR
BR
BR
BR
BR
BR
BR
B7
SC2BR
BR
BRB
R
BR
BR
BRBR BR
BR
BR
BR
R1
B1
B7
R1
R1
R1
P1
SC2
SC2
SC1(o)
SC1(O)
P1
B1(
u)
B2(
belo
w)
B2(below)
B2(below)
SC1SC1
BR
BR
BR
R2R2
R1
SC1(u)
SC2
R1
SC1
B2(
U) B1(
U)
B2(U)
B2(U)
P1
BR BR BR
BR
BR
BR BR
P1
SC1
SC1
11S9.04
RA
1
RAISED ROOF 1 OVERREFER DWG. S9.01
FOR DETAILS
RAISED ROOF 2 OVERREFER DWG. S9.01
FOR DETAILS
STAIR 2 ROOF OVERREFER DWG. S9.01
FOR DETAILS
STAIR 4 ROOF BELOWREFER DWG. S9.01
FOR DETAILS
SC1
SC1
RA
1
RA
1
RA
1
RA
1R
A1
P1
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
SC1
SC1
2S9.02
5S9.03
4S9.03
1S9.02
B1
B1
SC4
SC4
SC4
SC4
SC4
SC4
SC4
SC4
SC4
SC4
SC4
SC4
SC4
SC4 SC4
SC4
SC4
SC4
SC4
3S9.03
BR
BR
BR
BR
BR
ST1
B1
P2
RA1
RA1
ST
2
ST
2
ST
2
ST
2
ST
2
ST
2
ST
2ST2
ST
2
ST
2
ST
2
ST
2
ST
2
ST2
ST2
ST
2
ST
2
ST
2
RA
2
RA
1
B7
B2
B7 B7
B7
SC1(o)
B6
B6
B1
B6
B1
DL(
u)
HB
HB
HB
HH
H
DL(u)
H H
HB
HB
HB
HH
DL(
u)
HB
HDL(u)
H
DL(
u)
HB
HB
DL(u)
H H
HB
HB
HB HH
DL(
u)
HB
DL(u)
HH
HB
HB
H
H
DL(
u)
HB
HBHH
H
HB
H
DL(
u)HB
HB
HH
DL(
u)
HB
H
HB
HB
HBHH
H
H
HB HH
DL(
u)
HB
DL(
u)
HB
HB
HBHH
H
HB
HB
HH
DL(
u)
HB
DL(
u)
HB
HB
DL(u)H
H
HB
HB
HH
DL(
u)
HB
DL(u)
H
H
HB
HBHH
DL(
u)
HB
HBHH
H
DL(
u)
HB
HB
HB
HH
H
DL(
u)
HB
HB
HB
HH
H
DL(u)
H H
HB
HB
HB
HH
DL(
u)
HB
HBH
B
H
DL(u)HB
H
DL(
u)
HB
HB
DL(u)
H H
HB
HB HH
DL(
u)
HB
DL(u)
HH
HB
HB
HH
DL(
u)
HB
HB
HH
H
HB
H
DL(
u)
HB
HB
HH
DL(
u)
HB
H
HB
HH
DL(
u)
HB
DL(
u)
HB
HB
DL(u)H
H
HB
HB
HH
DL(
u)
HB
DL(u)
H
H
HB
HB
HH
DL(
u)
HB
HBHH
H
DL(
u)
HB
HB
HB
HH
H
HHB
HH
HB
HB
H
HB
HH
HB
HB H
HB
HH
HB
HB
B7 B
7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
DL(
u)
DL(
u)
DL(
u)
DL(
u)
7S9.04
ST1 ST1
SC4SC4
HB
HB
HBH
B
SC1(u)
FB
1
FB
1
FB1
FB1
FB1
FB1
HB HB
SC1(u)
SC1(o)
SC
1(o)
SC
1(u)
HBHB
8S9.04
9S9.04
BR
BR
BR
CRANK
SC1(u)
SC1(u)
HB
HB
HB
B1
10S9.04
P2
B6 B6 B6 B6 B6 B6
B6 B6
B6B6B6B6B6B6B6B6
RA
2R
A2
RA
2R
A2
B7
3xP
2
3xP
2
B3
B3
B5(O)
B5(
O)
B5(O)
B5(O)
B5(
O)
B5(O)
VOIDVOID
RA
1
RA
1R
A2
RA
2
RA
2R
A2
RA
2
MEMBER SCHEDULEMEMBER TAG MEMBER SIZE
RAFTERS
R1
R2
R3
R4
250 UB 26
310 UB 40
200 UB 22
150 UB 14
250 UB 31
360 UB 50
89 x 5.0 SHS
125 x 5.0 SHS
BEAMS
B1
B2
COLUMNS
SC1
SC2
180 UB 18B3
R5 180 UB 18
114.3 x 4.8 CHSSC3
150 UB 18B4
89 x 5.0 SHSB5
150 x 5.0 SHSB6
89 x 5.0 SHSSC4
125x75x6 RHSSC5
89 x 5.0 SHSDR1
MEMBER SCHEDULEMEMBER TAG MEMBER SIZE
PURLINS
P1
P2
SZ20012 PURLINS AT 1200 max. CENTRES
1000 max. END SPAN (SHEETING) LAP AND BRIDGE AS NOTED
SC20024 PURLINS AT 1200 max. CENTRES
1000 max. END SPAN (SHEETING) BRIDGE AS NOTED
P4SC10012 PURLINS AT 1200 max. CENTRES
1000 max. END SPAN (SHEETING) BRIDGE AS NOTED
250 PFCSB1
SC15012SB2
250x150x5 RHSSC6
75x4 RHSSC7
BRACES
BR 75 x 6 EA
STRUTS
ST1 Ø114.3 x 3.2 CHS (EQUIVALENT SHS = 100 x 3.0)
ST2 Ø76.1 x 2.3 CHS (EQUIVALENT SHS = 75 x 2.5)
RA2
90 x 6 EARA1
150 PFC
ST3 89 x 5.0 SHS
65 x 3.0 SHSH
150 PFCDL
250 UB 26B7
HB 50 x 3 EA
FB1 50 x 5.0 EA - PROVIDE FB TO EVERY THIRD PURLIN
G1 SC15015 GIRTS AT 900 max. CENTRES
P3SC20015 PURLINS AT 1200 max. CENTRES
1000 max. END SPAN (SHEETING) BRIDGE AS NOTED
PURLIN NOTES:1. UNLESS NOTED OTHERWISE ALL PURLINS SHALL BE LAPPED AS FOLLOWS:-
SPAN MINIMUM LAP
< 6000 900
> 6000 < 8000 1200
> 8000 < 12000 1500
> 12000 1800
2. PURLINS, GIRTS AND BRIDGING TO BE INSTALLED IN ACCORDANCE WITH
MANUFACTURERS SPECIFICATION.
3. UNLESS NOTED OTHERWISE PROVIDE PURLIN / GIRT BRIDGING AS FOLLOWS:-
NOTED: FIGURES IN BRACKETS APPLY TO SIMPLY SUPPORTED PURLINS
PURLIN SIZEMAXIMUM PURLIN SPAN
100
150
200
250
0 BRIDGES
2000
3000
4000
5000
1 BRIDGES 2 BRIDGES
4000 (3000)
6000 (5000)
8000 (7000)
10000 (8000)
6000 (5000)
9000 (7000)
12000 (9000)
15000 (12000)
NOTES:FOR ALL GENERAL STEELWORK NOTES REFER CONSTRUCTION NOTES ON DRAWING S1.00
ALL BOLTS FOR STEEL TO STEEL CONNECTIONS SHALL BE M20 GRADE 8.8/S U.N.O
ALL BRACE MEMBERS SHALL BE TIED TO EVERY SECOND PURLIN CROSSED WITH
UNISTRUT STRAP TO PREVENT SAG.
PRECAMBER TO ALL STRUCTURE STEEL RAFTERS, TRUSSES AND PORTALS
SHALL BE 5mm FOR EVERY 2000mm OF SPAN UNLESS NOTED OTHERWISE ON PLAN.
UNLESS NOTED OTHERWISE ALL EXTERNAL STRUCTURAL STEEL SHALL BE
HOT DIPPED GALVANISED.
UNLESS NOTED OTHERWISE FLY BRACE RAFTERS EVERY 3rd PURLIN.
PROVIDE FIRE PROTECTION TO ALL STRUCTURAL STEEL ELEMENTS AS REQUIRED
(REFER ARCHITECT'S DRAWING FOR FIRE RATING REQUIREMENTS)
1.
2.
3
4.
5.
6.
7.
This drawing and design remains the propery of Henry & Hymas and may not becopied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
ROOF FRAMING PLAN
S.W. T.M.
P.R. R.K.
18380-S9.00
JULY 2018
1 ISSUED FOR APPROVAL I.S. P.R. 27.09.2018
2 REVISED FOR TENDER T.L P.R. 17.10.2018
3 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SCALE 1 : 100
ROOF FRAMING
FOR CONSTRUCTION
MEMBER SCHEDULEMEMBER TAG MEMBER SIZE
RAFTERS
R1
R2
R3
R4
250 UB 26
310 UB 40
200 UB 22
150 UB 14
250 UB 31
360 UB 50
89 x 5.0 SHS
125 x 5.0 SHS
BEAMS
B1
B2
COLUMNS
SC1
SC2
180 UB 18B3
R5 180 UB 18
114.3 x 4.8 CHSSC3
150 UB 18B4
89 x 5.0 SHSB5
150 x 5.0 SHSB6
89 x 5.0 SHSSC4
125x75x6 RHSSC5
89 x 5.0 SHSDR1
MEMBER SCHEDULEMEMBER TAG MEMBER SIZE
PURLINS
P1
P2
SZ20012 PURLINS AT 1200 max. CENTRES
1000 max. END SPAN (SHEETING) LAP AND BRIDGE AS NOTED
SC20024 PURLINS AT 1200 max. CENTRES
1000 max. END SPAN (SHEETING) BRIDGE AS NOTED
P4SC10012 PURLINS AT 1200 max. CENTRES
1000 max. END SPAN (SHEETING) BRIDGE AS NOTED
250 PFCSB1
SC15012SB2
250x150x5 RHSSC6
75x4 RHSSC7
BRACES
BR 75 x 6 EA
STRUTS
ST1 Ø114.3 x 3.2 CHS (EQUIVALENT SHS = 100 x 3.0)
ST2 Ø76.1 x 2.3 CHS (EQUIVALENT SHS = 75 x 2.5)
RA2
90 x 6 EARA1
150 PFC
ST3 89 x 5.0 SHS
65 x 3.0 SHSH
150 PFCDL
250 UB 26B7
HB 50 x 3 EA
FB1 50 x 5.0 EA - PROVIDE FB TO EVERY THIRD PURLIN
G1 SC15015 GIRTS AT 900 max. CENTRES
P3SC20015 PURLINS AT 1200 max. CENTRES
1000 max. END SPAN (SHEETING) BRIDGE AS NOTED
2 3
C
D
SC1
SC1
SC1
SC1
SC1
R4
B4
R4
B4
P2
FALL
6 7
C
D
SC1SC1
SC1SC1
R4
R4
B4
B4
P2
FALL
SC1
8S9.04
8 9 10
D
E
F
P3
P3
R5
R5 B3
B3
R5
R5
R5
SC1SC1
SC1
P3
P3
R5
B3
FALL
FALL 4
S9.03
7S9.04
129.04
11
B
C
D
11S9.04
P4
RA
2
BR
BR
BR
BRBR
BR
SC3
SC3SC3
R1
B4
ST1
R1
FALL
SC2SC2
SC4
SC4
R1
SC3
BR
BR
B4
P4
R1
BR
ST1
RA
1
RA
1
LEVEL 3
LEVEL 4
6 7
SC
7
SB1
SB1
6 7
C
D
3
SB
2
SB
2
SB
2
SB
2
SB
2
SB
2
SB
2
SB
2
SB
2
SB1
SB1
SB1
SB
2
SB
2
SB
2SC
7
SC7
SB1
SC7
SC7
SC7
710 690 700 700 1100 640 760 700 700 700
SB2
PURLIN NOTES:1. UNLESS NOTED OTHERWISE ALL PURLINS SHALL BE LAPPED AS FOLLOWS:-
SPAN MINIMUM LAP
< 6000 900
> 6000 < 8000 1200
> 8000 < 12000 1500
> 12000 1800
2. PURLINS, GIRTS AND BRIDGING TO BE INSTALLED IN ACCORDANCE WITH
MANUFACTURERS SPECIFICATION.
3. UNLESS NOTED OTHERWISE PROVIDE PURLIN / GIRT BRIDGING AS FOLLOWS:-
NOTED: FIGURES IN BRACKETS APPLY TO SIMPLY SUPPORTED PURLINS
PURLIN SIZEMAXIMUM PURLIN SPAN
100
150
200
250
0 BRIDGES
2000
3000
4000
5000
1 BRIDGES 2 BRIDGES
4000 (3000)
6000 (5000)
8000 (7000)
10000 (8000)
6000 (5000)
9000 (7000)
12000 (9000)
15000 (12000)
NOTES:FOR ALL GENERAL STEELWORK NOTES REFER CONSTRUCTION NOTES ON DRAWING S1.00
ALL BOLTS FOR STEEL TO STEEL CONNECTIONS SHALL BE M20 GRADE 8.8/S U.N.O
ALL BRACE MEMBERS SHALL BE TIED TO EVERY SECOND PURLIN CROSSED WITH
UNISTRUT STRAP TO PREVENT SAG.
PRECAMBER TO ALL STRUCTURE STEEL RAFTERS, TRUSSES AND PORTALS
SHALL BE 5mm FOR EVERY 2000mm OF SPAN UNLESS NOTED OTHERWISE ON PLAN.
UNLESS NOTED OTHERWISE ALL EXTERNAL STRUCTURAL STEEL SHALL BE
HOT DIPPED GALVANISED.
UNLESS NOTED OTHERWISE FLY BRACE RAFTERS EVERY 3rd PURLIN.
PROVIDE FIRE PROTECTION TO ALL STRUCTURAL STEEL ELEMENTS AS REQUIRED
(REFER ARCHITECT'S DRAWING FOR FIRE RATING REQUIREMENTS)
1.
2.
3
4.
5.
6.
7.
4 5
A
B
C
FALL
1S9.02
P1
P1
B1
R3
RA
1
RA
1
9S9.04
10S9.04
CS9.07
This drawing and design remains the propery of Henry & Hymas and may not becopied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
STEEL FRAMING PART PLANS
S.W. T.M.
P.R. R.K.
18380-S9.01
JULY 2018
1 ISSUED FOR APPROVAL I.S. P.R. 27.09.2018
2 REVISED FOR TENDER T.L P.R. 17.10.2018
3 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SCALE 1 : 100
RAISED ROOF 1 FRAMING PLANSCALE 1 : 100
RAISED ROOF 2 FRAMING PLAN
SCALE 1 : 100
AWNING ROOF FRAMING PLANSCALE 1 : 100
STAIR 4 ROOF FRAMING PLAN
FOR CONSTRUCTION
SECTION-SCALE 1 : 100
3
SCALE 1 : 100
STAIR PLAN VIEW
SCALE 1 : 100
STAIR 2 ROOF FRAMING PLAN
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
1234567891011
ROOF
7S9.04
1S9.06
2S9.06
3S9.06
9S9.04
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
5
SC
5
SC
4
SC
4
SC
4
SC
4
SC
5
SC
5
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
2
SC
2
SC
2
SC
2
SC
2
SC
2
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B6 B6 B6 B6 B6 B6B6B6
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
1 2 3 4 5 6 7 8
ROOF
9S9.04
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
4
SC
2
SC
2
SC
2
SC
2
SC
2
SC
2
SC
2
SC
2
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B6 B6 B6
B5
B5
B5
B5
B5
B5
B5
B5
B1
B5
B5
B5
B5
B5
B5
B5
B6
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B6
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
C5
C5
C5
C5
C5
C5
C5
C5
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 100
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
ELEVATIONS SHEET 1
S.W. T.M.
P.R. R.K.
18380-S9.02
JULY 2018
1 ISSUED FOR APPROVAL I.S. P.R. 27.09.2018
2 REVISED FOR TENDER T.L P.R. 17.10.2018
3 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SECTIONSCALE 1 : 100 S6.00
1
SECTIONSCALE 1 : 100 S6.00
2 FOR CONSTRUCTION
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
B C D
ROOF
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B1 B6 B6 B6
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
9 10 11
ROOF
7S9.04
1S9.06
2S9.06
3S9.06
YS9.06
SC
4
SC
4S
C4
SC
2
SC
2
SC
2
SC
4
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B6 B6
C2
C2
C2
C2
C2
C2
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
5 6 7
ROOF
6S9.03
SC
6
DR
1
SC
6
DR
1
DR
1
ST
3
SC
4
ST
3
ST
3
B5
B5
B5 B5 B5
B5 B5 B5
B5
B5
C2
LEVEL 2
LEVEL 3
D
CEILING LEVEL
ST3
3S9.03
DR
1
B5
B5
CEILING LEVEL
TYPICAL
45.00°
HB
H
2M16 CHEMSETS
125 MIN. INTO CONCRETE
2M16 CHEMSETS
125 MIN. INTO CONCRETE
TYPICAL
8 PLATE
8 PLATE
8 PLATE
2-M16 BOLTS
TYPICAL
DL
HB
PURLIN
H
8 PLATE
2-M16 BOLTS
TYPICAL
DL
HB
H
8 PLATE
2-M16 BOLTS
TYPICAL
DL
RAFTER BEAM B7
C15015
STANDARD GP BRACKET
2-M12 BOLTS EACH
CONNECTION
PURLIN
SLAB
12 CAP PALTE
4 M20 BOLTS
12 CAP PALTE
4 M20 BOLTS
2 M12 BOLTS2 M12 BOLTS
TYPICAL OPERABLE WALL - SLAB FIXING DETAIL TYPICAL OPERABLE WALL - PERPENDICULAR PURLIN FIXING DETAIL TYPICAL OPERABLE WALL - PARALLEL PURLIN FIXING DETAIL
800
MA
X.
TO ACCOMMODATE
DIFFERENCE IN
CEILING LEVEL
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
ELEVATIONS SHEET 2
S.W. T.M.
P.R. R.K.
18380-S9.03
JULY 2018
1 ISSUED FOR APPROVAL I.S. P.R. 27.09.2018
2 REVISED FOR TENDER T.L P.R. 17.10.2018
3 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SECTION-SCALE 1 : 100
6
FOR CONSTRUCTION
SECTIONSCALE 1:100
3S9.00
SECTIONSCALE 1:100
4S9.00
SECTIONSCALE 1:100
5S9.00
LEVEL 4
ABCD
ROOF
4S9.03
1S9.02
R1R1
SC
2
SC
2
SC
2
SC
2
B6B6
B5
B5
B5
B5
DLDL
H H H H H H
B1
B7
B1
LEVEL 4
ABCDEF
ROOF
2S9.02
1S9.02
RA2
RA1
RA2 BEHIND
R1
SC
2
C2
C4
B4
900RA2
RA1
300
LEVEL 4
6 7
ROOF
SC
1
SC
1
SC
2
C4
B2
R2
SC1
B4
B1
AS9.07
B5
LEVEL 2
LEVEL 3
8 9 10
R5B3B3
R5
R5 BEHIN
D
SC
1
SC
1
PF1 PF1
C5
BS9.07
LEVEL 4
B C D
RA2
ST1
B4
SC
3
R1
LEVEL 4
BC
ROOF
R3
B4
G
L.V.
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 100
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
ELEVATIONS SHEET 3
Author T.M.
P.R. R.K.
18380-S9.04
01/17/19
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SECTIONSCALE 1 : 100 S9.00
7
SECTIONSCALE 1 : 100 S9.00
9
SECTIONSCALE 1 : 100 S9.00
8
FOR CONSTRUCTIONSECTIONSCALE 1:100
12S9.01
SECTIONSCALE 1 : 100 S9.01
11
SECTIONSCALE 1 : 100 S9.00
10
10 CLEAT PLATE
2-M20 BOLTS EACH
CONNECTION
1-M20 BOLT
TYPICAL BRACING INTERSECTION DETAIL
PURLIN
50 x 5 EA (FB)
1-M12 BOLT EACH END
8 CLEAT PLATE
BOTH SIDES
TYPICAL FLYBRACE DETAILNOTED FB ON PLAN
PURLIN CLEAT
2-M12 BOLTS
HEIGHT 'A'mm CLEAT SIZE
PURLIN
RAFTER
TYPICAL PURLIN CLEAT DETAIL
CLEAT SCHEDULE
0 - 250
250 - 350
350 - 450
450 +
12 PLATE
75 x 6 EA
10 PLATE
8 PLATE
' A'
6
'ST' TYPE MEMBER
CLEAT
PROVIDE ø22 HOLES AS
REQUIRED TO SUIT M20
BOLTS
10 PLATE STIFFENER
6
'ST' TYPE MEMBER
CLEAT
PROVIDE ø22 HOLES AS
REQUIRED TO SUIT M20
BOLTS
ANGLE CLEAT SCHEDULEMEMBER SIZE CLEAT SIZE CLEAT LENGTH
ø88.9 CHS
ø101.6 CHS
ø114.3 CHS
ø139.7 CHS
ø165.1 CHS
ø168.3 CHS
ø219.1 CHS
100 x 75 x 6 UA
125 x 75 x 6 UA
125 x 75 x 6 UA
150 x 90 x 10 UA
200 x 90 x 13 UA
(EX 200 x 13 EA)
200 x 90 x 13 UA
(EX 200 x 13 EA)
230 x 100 x 12 P CLEAT
c/w STIFFENER PLATE
(refer detail above)
140
140
140
160
180
180
230
* WHERE 3 BOLTS ARE SPECIFIED CLEATS SHALL BE PROVIDE
minimum 210 LONG
FLANGES (typical)
WEB (typical)8
a-
25 END PLATE (typ)
8-M20 8.8/TB BOLTS
RAFTER SAME SIZES
= =
140
5070
5070
b-
500
10 PLATE GUSSET ON
CENTERLINE OF BEAM
25 END PLATE (typ)
10-M20 8.8/TB BOLTS
RAFTER VARYING SIZESECTION a-
TYPICAL RAFTER SPLICE DETAILSREFER MARKING PLAN FOR LOCATIONS AND MEMBER SIZES
8
8WEB (typical)
FLANGES (typical)
SECTION b-
= =
140
7050
5050
70
8
10 PLATE GUSSET ON
CENTERLINE OF BEAM
10 PLATE GUSSET ON
CENTERLINE OF BEAM
WEB SIDE PLATE CONNECTION SCHEDULE
TYPICAL WEB SIDE PLATE CONNECTION DETAILS 180 PFC / 180 UB AND ABOVETYPICAL WEB SIDE PLATE CONNECTION DETAILS
150 PFC / 150 UB AND BELOW
MEMBER SIZE BOLTS (No. - SIZE, GRADE) CLEAT PLATE THICKNESS (mm)
6 CFW BOTH SIDES
UNCOPED DOUBLE WEB COPEDSINGLE WEB COPED
REFER SCHEDULE FOR CLEAT PLATE THICKNESSAND BOLT SIZE AND NUMBER.
MEMBER SIZE REFERSCHEDULEOF CLEAT
6 CFW BOTH SIDES
REFER SCHEDULE FOR CLEAT PLATE THICKNESSAND BOLT SIZE AND NUMBER.
MEMBER SIZE REFERSCHEDULEOF CLEAT
6 CFW BOTH SIDES
REFER SCHEDULE FOR CLEAT PLATE THICKNESSAND BOLT SIZE AND NUMBER.
MEMBER SIZE REFERSCHEDULEOF CLEAT
DOUBLE WEB COPED
SINGLE WEB COPED
UNCOPED
6 CFW BOTH SIDESOF CLEAT
2-M20 8.8/S BOLTS10mm THICK CLEAT PLATE
MEMBER SIZE150 PFC / 150 UB AND UNDER
6 CFW BOTH SIDESOF CLEAT
6 CFW BOTH SIDESOF CLEAT
2-M20 8.8/S BOLTS10mm THICK CLEAT PLATE
MEMBER SIZE150 PFC / 150 UB AND UNDER
2-M20 8.8/S BOLTS10mm THICK CLEAT PLATE
MEMBER SIZE150 PFC / 150 UB AND UNDER
360 UB
310 UB & 310 UC
250 UB & 250 UC
200 UB & 200UC
3-M20 8.8/S
3-M20 8.8/S
2-M20 8.8/S
2-M20 8.8/S
CHANNELS
380 PFC
UNIVERSAL BEAMS / COLUMNS
300 PFC
180 PFC, 200 PFC, 230 PFC
250 PFC
4-M20 8.8/S
3-M20 8.8/S
2-M20 8.8/S
2-M20 8.8/S 10
10
10
10
10
10
10
10
410 UB 4-M20 8.8/S 10
460 UB 5-M20 8.8/S 10
530 UB 6-M20 8.8/S 10
610 UB 7-M20 8.8/S 10
WELDED BEAMS
700 WB 8-M20 8.8/S 10
800 WB 9-M20 8.8/S 10
180 UB 2-M20 8.8/S 10
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
STEEL DETAILS SHEET 1
IS T.M.
P.R. R.K.
18380-S9.05
08/04/17
1 TENDER ISSUE I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
FOR CONSTRUCTION
20 GROUT LEVALLINGBED (typical)
2-off M20 HILTI HIT HY200170 minimum EMBEDMENT
(typical)
SECTION - FOOTING / SLAB SECTION - FOOTING / SLAB
20 GROUT LEVELLING BED
(typical)2-off M20 HILTI HIT HY200170 minimum EMBEDMENT
(typical)
20 GROUT LEVELLING BED
(typical)
RC SLAB AND RECESSAS DETAILED
2-off M20 HILTI HIT HY200170 minimum EMBEDMENT
(typical)
SECTION - SLAB (RECESSED)
RC SLAB AND RECESSAS DETAILED 20 GROUT
LEVELLING BED
(typical)2-off M20 HILTI HIT HY200170 minimum EMBEDMENT
(typical)
SECTION - SLAB (RECESSED)
16 BASEPLATE 2-off Ø26 HOLES
TO SUIT M20 BOLTS90 ==
90
= =
PLAN
TYPICAL COLUMN BASEPLATE (89 SHS)
TYPICAL COLUMN BASEPLATE (89 SHS)
16 BASEPLATE2-off Ø26 HOLES
TO SUIT M20 BOLTS
PLAN
250
= 180 =
90 ==
75 75
20 GROUTLEVELLING BED
(typical)2-off M20 HILTI HIT HY200170 minimum EMBEDMENT
(typical)
SECTION - FOOTING / SLAB SECTION - FOOTING / SLAB
20 GROUTLEVELLING BED
(typical)2-off M20 HILTI HIT HY200170 minimum EMBEDMENT
(typical)
75RC SLAB AND RECESSAS DETAILED
2-off M20 HILTI HIT HY200170 minimum EMBEDMENT
(typical)
20 GROUT LEVELLINGBED (typical)
SECTION - SLAB (RECESSED)
20 GROUT LEVELLINGBED (typical)
75RC SLAB RECESSAS DETAILED
2-off M20 HILTI HIT HY200170 minimum EMBEDMENT
(typical)
SECTION - SLAB (RECESSED)
16 BASEPLATE2-off Ø26 HOLES
TO SUIT M20 BOLTS
PLAN
115 =
=115
= =
TYPICAL COLUMN BASEPLATE(125 SHS)
TYPICAL COLUMN BASEPLATE(125 SHS)
PLAN
270
= 200 =
115
==
16 BASEPLATE2-off Ø26 HOLES
TO SUIT M20 BOLTS
STEEL COLUMN ASSCHEDULED (typical)
TYPICAL COLUMN TO RAFTER CONNECTION
20 CAP PLATE4-M20 BOLTS
STEEL COLUMN ASSCHEDULED (typical)
10 T-PLATE2-M20 BOLTS FOR 250 UB
3-M20 BOLTS FOR 310 UB
RAFTER OR BEAM ASSCHEDULED (typical)
RAFTER OR BEAM ASSCHEDULED (typical)
10 END PLATE4-M20 CHEMICAL ANCHORS
20 GROUT
RAFTER OR BEAM ASSCHEDULED (typical)
TYPICAL RAFTER TO REDIWALL CONNECTION
10 STIFFENERTYPICAL
B5
10 PLATE2M16 CHEMICAL ANCHOR
20 GROUT1M20
B5
SC
4
X-
SECTION X-
6 PLATE
6 PLATE
SC42-M12 MASONRY ANCHORSTO CONCRETE SLAB
2-off 150 x 90 x 10 UA2-M20 BOLTS
40 SLOTTED HOLES
a-
B5 B5
SC2
This drawing and design remains the propery of Henry & Hymas and may not becopied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 10
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
STEEL DETAILS SHEET 2
Author T.M.
P.R. R.K.
18380-S9.06
10/23/18
1 TENDER ISSUE I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
DETAILSCALE 1 : 10 S9.02
1
DETAILSCALE 1 : 10 S9.02
2
DETAILSCALE 1 : 10 S9.02
3
FOR CONSTRUCTION
SECTIONSCALE 1 : 10 S9.03
Y
SECTION a
120
= =
140
120
FLANGES (typical)
WEB (typical)6
10 PLATE GUSSET ON
CENTERLINE OF BEAM
25 END PLATE (typ)
8-M20 8.8/TB BOLTS
TYPICAL APEX DETAIL
6
50
a
STRUT
RA
FT
ER
BRACE
BRACE
PLATES AND BOLTS
AS DETAILED
RAFTER OR BEAM
TYPICAL BRACING STRUT CONNECTION DETAILS
16 BASE PLATE
4N20 BOLTS
TYPICAL
SC
1
SC
1
R2
B2
10 SITFFERNER
100
6 CAP PLATE
10 'T' PLATE
2M20 BOLTS
SC
1
R5 B3
B3
50
WALL AS DETAILED
PURLIN AS DETAILED
RA1
PURLIN CONNECTION
AS DETAILED
M16-900 CHEMICAL
ANCHORS
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
1 : 10
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
STEEL DETAILS SHEET 3
Author Designer
Checker Approver
18380-S9.07
01/24/19
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
FOR CONSTRUCTION
DETAILSCALE 1 : 10 S9.04
A DETAILSCALE 1 : 10 S9.04
B SECTIONSCALE 1 : 10 S9.01
C
CJ
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
AB
F1
F2
F3
F4
F5
F6
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
AB
F2
F3
F4
F5
F6
F7
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
AB
ROOF
F1
F2
F3
F4
F5
F6
F7
F8
LEVEL 2
LEVEL 3
LEVEL 4
CD
WALL W11
REFER WALL ELEVATIONS
ON SHEET S3.01
F1
F2
F3
F4
F5
F6
30'X' BARS
'V' BARS
'V' BARS
't'
REID BOX OR APPROVED
EQUIVALENT.
N16 'U' BARS AT 200
600 LEGS
RC WALL LANDING
30
'X' BARS
REFER TYPICAL
SUPPORT DETAILS
't'
SUPPORT
'V' BARS
'X' BARS
450
450
'V' BARS
'X' BARS
0.3 'L'
't'
'X' BARS
'V' BARS
150
450SUPPORT'X' BARS
'V' BARS
'X' BARS
REFER TYPICAL
SUPPORT DETAILS
't''V' BARS
'X' BARS
450
750
TYPICAL SECTION THROUGH STAIR FLIGHTFOR REINFORCEMENT DESIGNATIONS i.e. 'X' or 'V' BARS
REFER STAIR SCHEDULES (TYPICAL)
'L'
0.3 'L'
'X' BARS
'V' BARS
450 'X' BARS
't'
'X' BARS
450
'V' BARS
'V' BARS
'X' BARS
'V' BARS
'X' BARS
700
450
'V' BARS
'X' BARS
TYPICAL SECTION THROUGH MID-LANDINGFOR REINFORCEMENT DESIGNATIONS i.e. 'X' or 'V' BARS
REFER STAIR SCHEDULES (TYPICAL)
SUPPORT
'V' BARS
'X' BARS
450
't'
'X' BARS
SLIP JOINT
PROVIDE 2 LAYERS
OF ALCOR (TYPICAL)
450
'V' BARS
'V' BARS
'X' BARS
'X' BARS
TYPICAL STAIR SUPPORT DETAILS
BLOCKWORK WALL
SUPPORT
450
450
SLAB REINFORCEMENT SHOWN THUS
(REFER SLAB REINF'T PLAN FOR DETAIL)
FOR BEAM REINFORCEMENT
REFER SLAB REINFORCEMENT
PLAN OR BEAM ELEVATION
'X' BARS
'V' BARS
'X' BARS
R.C. BEAM
450
30'V' BARS
'X' BARS
450
'V' BARS
'V' BARS
'X' BARS
'X' BARS
'X' BARS
't'
REID BOX OR APPROVED
EQUIVALENT.
N16 'U' BARS AT 200
600 LEGS
SUPPORT
RC WALL
STAIR ST1 SCHEDULE
FLIGHT No. X BARSTHROAT
THICKNESSV BARS
F1
F2
210
210
N16-200
N16-200
N12-300
N12-300
F3 210 N16-200 N12-300
F4
F5
210
210
N16-200
N16-200
N12-300
N12-300
F6 210 N16-200 N12-300
STAIR ST1 SCHEDULE
FLIGHT No. X BARSTHROAT
THICKNESSV BARS
F1
F2
210
210
N16-200
N16-200
N12-300
N12-300
F3 210 N16-200 N12-300
F4
F5
210
210
N16-200
N16-200
N12-300
N12-300
F6 210 N16-200 N12-300
STAIR ST1 SCHEDULE
FLIGHT No. X BARSTHROAT
THICKNESSV BARS
F1
F2
210
210
N16-200
N16-200
N12-300
N12-300
F3 210 N16-200 N12-300
F4
F5
210
210
N16-200
N16-200
N12-300
N12-300
F6 210 N16-200 N12-300
STAIR ST1 SCHEDULE
FLIGHT No. X BARSTHROAT
THICKNESSV BARS
F1
F2
210
210
N16-200
N16-200
N12-300
N12-300
F3 210 N16-200 N12-300
F4
F5
210
210
N16-200
N16-200
N12-300
N12-300
F6 210 N16-200 N12-300
STAIR SCHEDULE
STAIR No. X BARSTHROAT
THICKNESSV BARS
ST1-ST4
ST5 210 N16-200 N12-300
ST6 210 N16-200 N12-300
ST7 210 N16-200 N12-300
AS SHOWN
This drawing and design remains the propery of Henry & Hymas and may not be
copied in whole or in part without prior written approval of Henry & Hymas
Client
Architect
Project
Title
Drawn
Checked
Designed
Approved
Date
Scale
Drawing number Revision
Level 5,79 Victoria Avenue
Chatswood NSW 2067
Telephone
+61 2 9417 8400
Facsimile
+61 2 9417 8337
www.henryandhymas.com.au
DATEDESIGNEDDRAWNREVISION AMENDMENT
A1
As indicated
ANBRS ARCHITECTURE
WAITARA PUBLIC SCHOOL REDEVELOPMENTNSW DEPARTMENT OF EDUCATION68 EDGEWORTH DAVID AVENUE, WAHROONGA 2076
STAIR DETAILS
Author T.M.
P.R. R.K.
18380-S10.00
10/24/18
1 REVISED FOR TENDER I.S. P.R. 26.10.2018
A ISSUED FOR CONSTRUCTION I.S. P.R. 25.01.2019
SCALE 1 : 100
STARI SECTION ST1
SCALE 1 : 100
STARI SECTION ST3
SCALE 1 : 100
STARI SECTION ST2
SCALE 1 : 100
STARI SECTION ST4
NOTE:UNO ALL LANDINGS TO BE:
210 THICK
V BARS = N16-200
X BARS = N12-300
FOR CONSTRUCTION