a1 s100e - buyandsell.gc.ca...- csa s16-14 design of steel structures - csa o86-14 engineering...
TRANSCRIPT
GENERAL1. THIS IS A METRIC PROJECT. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN MILLIMETERS.
2. ALL REFERENCED STANDARDS SHALL BE THE CURRENT EDITION OF THE EDITION REFERENCED BY THE APPLICABLE BUILDING CODEIN FORCE AT THE TIME OF FABRICATION.
3. “WSP-S” REFERS TO WSP CANADA STRUCTURAL CONSULTANT.
4. PROVIDE ALL MATERIAL AND LABOUR REQUIRED FOR COMPLETION OF THE WORK.
5. PRIOR TO CONSTRUCTION, REVIEW STRUCTURAL DRAWINGS IN CONJUNCTION WITH DRAWINGS PROVIDED BY ALL OTHERCONSULTANTS, AND WITH EXISTING CONDITIONS.
6. REPORT DISCREPANCIES TO THE CANADIAN COAST GUARD BEFORE PROCEEDING WITH THE WORK.
7. VERIFY EXISTING DIMENSIONS AND CONDITIONS ON SITE PRIOR TO CONSTRUCTION.
8. THESE DRAWINGS HAVE BEEN PREPARED ONLY FOR THE PURPOSE IDENTIFIED IN THE REVISIONS COLUMN. DO NOT CONSTRUCTFROM THESE DRAWINGS UNLESS THEY ARE ISSUED WITH A STATEMENT OF WORK FROM THE CANADIAN COAST GUARD. WSP WILLNOT BE HELD RESPONSIBLE OR LIABLE FOR ANY DEVIATIONS AND/OR CHANGES FROM THESE DRAWINGS. ANY CONSEQUENCES AS ARESULT OF DEVIATIONS/CHANGES WILL BE THE SOLE RESPONSIBLITY OF THE CONTRACTOR, THE CANADIAN COAST GUARD AND ANYOTHER PARTIES RESPONSIBLE FOR THE DEVIATIONS/CHANGES. WSP WILL NOT BE RESPONSIBLE FOR THE CONSTRUCTION OF THEWORK OR CONTRACT ADMINISTRATION DURING CONSTRUCTION.
9. DO NOT USE INFORMATION ON THESE DRAWINGS FOR ANY OTHER PROJECT OR WORKS.
10. DO NOT SCALE THESE DRAWINGS.
11. ALL SECTIONS, DETAILS, AND STATEMENTS NOTED AS “TYPICAL” APPLY TO LIKE/SIMILAR CONDITIONS IN THE STRUCTURE.
12. DRAWINGS SHOW COMPLETED STRUCTURE ONLY. THEY DO NOT SHOW TEMPORARY WORKS FOR WHICH THE CONTRACTOR ISRESPONSIBLE AND WHICH MAY BE REQUIRED FOR EXECUTION OF THE PROJECT. THE CONTRACTOR TO ESTABLISH CONSTRUCTIONPROCEDURE AND SEQUENCE TO ENSURE SAFETY OF THE WHOLE STRUCTURE AND ALL ITS COMPONENTS DURING ERECTION.
13. MAKE ADEQUATE PROVISIONS FOR ALL LOADS ACTING ON THE STRUCTURE DURING ERECTION. PROVIDE TEMPORARY SHORING ANDBRACING TO KEEP THE STRUCTURE PLUMB AND IN TRUE ALIGNMENT DURING CONSTRUCTION.
14. DESIGN OF ALL TEMPORARY WORKS TO BE CARRIED OUT BY A PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR,LICENSED IN THE PLACE WHERE THE PROJECT IS LOCATED.
15. CONSTRUCTION LOADS ON COMPLETED STRUCTURE NOT TO EXCEED DESIGN LOADS INDICATED ON DRAWINGS.
16. WHERE INDICATED AS “A QUALIFIED CANADIAN COAST GUARD REPRESENTATIVE” IN THESE DOCUMENTS SHALL MEAN A PERSONWITH THE APPROPRIATE PROFESSIONAL TRAINING IN ACCORDANCE WITH ALL PREVAILING CODES, STANDARDS AND REGULATIONS.
DESIGN CRITERIA1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE 2015 NATIONAL BUILDING CODE (NBC), SUPPLEMENTED BY THE 2015 NATIONAL
BUILDING CODE OF CANADA STRUCTURAL COMMENTARY.
2. DESIGN IS ALSO SUPPLEMENTED BY THE FOLLOWING CODES & REGULATIONS:- NATIONAL BUILDING CODE OF CANADA (NBCC) 2015- CANADA LABOUR CODE (R.S.C., 1985, c. L-2)- CANADIAN AVIATION REGULATIONS - 2017 PART III- CSA S16-14 DESIGN OF STEEL STRUCTURES- CSA O86-14 ENGINEERING DESIGN IN WOOD- CSA S157-17 STRENGTH DESIGN IN ALUMINUM- CSA W47.2-11 (R2015), CERTIFICATION OF COMPANIES FOR FUSION WELDING OF ALUMINUM- CSA W59.2-18, WELDED ALUMINUM CONSTRUCTION- CAN/CGSB-48.9217-2006/ISO 9712:2005 NON-DESTRUCTIVE TESTING - QUALIFICATION AND CERTIFICATION OF
PERSONNEL.- ACSE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES- ASTM B209M-14, STANDARD SPECIFICATION FOR ALUMINUM AND ALUMINUM-ALLOY SHEET AND PLATE.- ASTM B308M-10, STANDARD SPECIFICATION FOR ALUMINUM-ALLOY 6061-T6 STANDARD STRUCTURAL PROFILES.- ASTM A193/A193M-17, STANDARD SPECIFICATION FOR ALLOY-STEEL AND STAINLESS-STEEL BOLTING FOR HIGH
TEMPERATURE OR HIGH-PRESSURE SERVICE AND OTHER SPECIAL PURPOSE APPLICATIONS.- AWS A5.10/A5.10M (2017), SPECIFICATION FOR BARE ALUMINUM AND ALUMINUM ALLOY WELDING ELECTRODE AND
RODS.
3. ALL REFERENCED STANDARDS SHALL BE THE CURRENT EDITION OF THE EDITION REFERENCED BY THE APPLICABLE BUILDING CODEIN FORCE AT THE TIME OF FABRICATION.
4. THE VALUES FOR CLIMATIC DATA USED IN THE DETERMINATION OF DESIGN LOADS HAVE BEEN OBTAINED FROM THE 2015 NBC FORTHE SPECIFIC LOCATIONS OF ONTARIO, QUEBEC AND NUNAVUT. THE MUNICIPALITY WITH THE MOST CONSERVATIVE DESIGN LOADDATA FOR SNOW, WIND, & SEISMIC FORCES HAS BEEN CHOSEN AS THE BASIS OF THE DESIGNS. FOR SITE LOCATIONS GREATERTHAN 50km AWAY FROM THE NEAREST LISTED LOCATIONS IN THE NBCC 2015 PUBLISHED DATA, THE LOAD CONDITIONS SHALL BEREVIEWED BY A QUALIFIED PROFESSIONAL ENGINEER, LICENSED IN THE PROVINCE/TERRITORY OF WORK. FOR EARTHQUAKEFORCES FOR LOCATIONS OUTSIDE OF THE PUBLISHED DATA, LOAD CONDITIONS SHALL BE CALCULATED BY A QUALFIEDPROFESSIONAL ENGINEER, LICENSED IN THE PROVINCE/TERRITORY OF WORK.
5. BASED ON THE USE AND OCCUPANCY, THE STRUCTURE IS DESIGNED TO THE REQUIREMENTS OF A LOW IMPORTANCE CATEGORY.
6. SELF WEIGHT (SWT) IS DUE TO THE WEIGHT OF THE STRUCTURE ITSELF. IT VARIES WITH THE STRUCTURAL SYSTEM.
7. SUPERIMPOSED DEAD LOADS (SDL) ARE NON-STRUCTURAL DEAD LOADS DUE TO NON-STRUCTURAL TOPPINGS, FINISHES,PARTITIONS, ROOFING MATERIALS, SUSPENDED EQUIPMENT, PAVERS, SOIL, ETC.
8. DEAD LOAD (DL) IS THE SELF WEIGHT OF THE STRUCTURE PLUS THE SUPERIMPOSED DEAD LOAD.
9. UNLESS OTHERWISE NOTED, DESIGN LOADS SHOWN ON DRAWINGS ARE SPECIFIED (UNFACTORED) LOADS, TO BE USED FOR ULSDESIGN. FOR SLS DESIGN, THESE LOADS CAN BE REDUCED BY MULTIPLYING WITH THE RATIO OF APPROPRIATE IMPORTANCEFACTORS Ix(SLS) / Ix(ULS) GIVEN BELOW.
10. IF ONLY ONE VALUE IS GIVEN FOR A LOAD, CONSIDER IT A LIVE LOAD.
11. FOR CONNECTION LOADS, “+” SIGN INDICATES TENSION AND “-“ SIGN INDICATES COMPRESSION, EXCEPT FOR COLUMN LOADSWHERE “+” SIGN INDICATES COMPRESSION AND “-“ SIGN INDICATES TENSION.
12. SNOW: (MAX SNOW LOAD FOR EACH REGION)
THE THREE SELECTED REGIONS BELOW REPRESENTING THE WORST CASE CLIMATIC DATA FOR EACH PROVINCE/TERRITORY, THEYPRODUCE THE HIGHEST SNOW AND WIND COMBINED LOADING.
1. QUEBEC (HARRINGTON HARBOUR)1. Ss = 4.9 kPa; Sr = 0.6 kPa; Is (ULS) = 0.8; Is (SLS) = 0.9
2. NUNAVUT (NOTTINGHAM ISLAND)1. Ss = 4.7 kPa; Sr = 0.2 kPa; Is (ULS) = 0.8; Is (SLS) = 0.9
3. ONTARIO (CHAPLEAU)1. Ss = 3.6 kPa; Sr = 0.4 kPa; Is (ULS) = 0.8; Is (SLS) = 0.9
SPECIFIC SNOW LOAD IS CALCULATED AS S = Is[SsCbCsCa + Sr]WHERE Cb = 0.8, Cw = 1.0, Cs = 1.0 & Ca = 1.0
THUS FOR THE HIGHEST SNOW LOAD - QUEBEC (HARRINGTON HARBOUR) S = 3.6kPa
13. RAIN: 24 HOUR RAINFALL1. QUEBEC (HARRINGTON HARBOUR) = 96 mm2. NUNAVUT (NOTTINGHAM ISLAND) = 54 mm3. ONTARIO (CHAPLEAU) = 97 mm
14. LATERAL LOADS IN THIS STRUCTURE ARE RESISTED BY BRACED FRAMES, AND ARE DETERMINED BASED ON THE WIND AND SEISMICDATA BELOW.
15. WIND:
1. QUEBEC (HARRINGTON HARBOUR) q50 = 0.72 kPa; Iw (ULS) = 0.8; Iw (SLS) = 0.752. NUNAVUT (NOTTINGHAM ISLAND) q50 = 0.78 kPa; Iw (ULS) = 0.8; Iw (SLS) = 0.753. ONTARIO (CHAPLEAU) q50 = 0.30 kPa; Iw (ULS) = 0.8; Iw (SLS) = 0.75
NOTE: FOR ONTARIO REGION, THE LOCATION FOR THE HIGHEST SNOW LOAD DOES NOT CORRELATE TO THE HIGHEST WIND LOAD(PORT ELGIN q50 =0.55kPa), IN ORDER TO ENSURE THAT THE DESIGN WILL BE APPLICABLE TO ALL THREE PROVINCES/TERRITORIES,THE HIGHEST WIND LOAD q50 = 0.78kPa WAS USED FOR THE WIND LOAD CALCULATIONS.
TERRAIN TYPE: OPEN TERRAIN (h/10)0.2 >= 0.9
WIND LOAD AS PER PART 4 of NBC 2015
p = IwqCeCtCgCp Iw = 0.8 (LOW)= (0.8)(0.78)(0.93)(3.255)(2.0)(0.8) q = 0.78 (NUNAVUT, NOTTINGHAM ISLAND, HIGHEST VALUES OF 3 REGIONS)
= 3.02 KPa (WINDWARD) Ce = 0.93Ct = 3.255 (MAXIMUM VALUE FOR ESCARPENT WIND SPEED UP)
= (0.8)(0.78)(0.93)(3.255)(2.0)(-0.5) Cg = 2.0 = 1.89 KPa (LEEWARD) Cp = 0.8 (WINDWARD), -0.5 (LEEWARD)
16. SEISMIC
THE THREE SELECTED REGIONS BELOW REPRESENTING THE WORST SEISMIC DATA FOR EACH PROVINCE.
QUEBEC (LA-MALBAIE)Sa (0.2) = 1.73 IeFaSa(0.2) = 1.38Sa (0.5) = 0.954 (SITE CLASS C)Sa(1.0) = 0.454Sa(2.0) = 0.203PGA = 1.04
NUNAVUT (CLYDE RIVER)Sa (0.2) = 0.306 IeFaSa(0.2) = 0.30Sa (0.5) = 0.186 (SITE CLASS E)Sa(1.0) = 0.104Sa(2.0) = 0.053PGA = 0.195
ONTARIO (ALEXANDRIA)Sa (0.2) = 0.589 IeFaSa(0.2) = 0.45Sa (0.5) = 0.309 (SITE CLASS E)Sa(1.0) = 0.148Sa(2.0) = 0.068PGA = 0.376
IE = 0.8 (IMPORTANCE: LOW)Rd = 1.5Ro = 1.3SITE CLASSIFICATION = ESEISMIC FORCE RESISTING SYSTEM (SFRS): BRACED FRAMES
DESIGN LOADS TYPE MAXIMUM VALUES OUT OF THE 3 REGIONS/TERRITORIESUSED FOR DESIGN
GOVERNING REGION/TERRITORY
SNOW 3.6kPa QUEBEC (HARRINGTON HARBOUR)
WIND (LIGHTHOUSEWINDWARD/LEEWARD)
3.02kPa/1.89kPa NUNAVUT (NOTTINGHAM ISLAND)
SEISMIC IeFaSa(0.2) = 1.38 (SITE CLASS C) QUEBEC (LA-MALBAIE)
FOR SITE LOCATIONS GREATER THAN 50km AWAY FROM THE NEAREST LISTED LOCATIONS IN THE NBCC 2015 PUBLISHED DATA, THELOAD CONDITIONS SHALL BE REVIEWED BY A QUALIFIED PROFESSIONAL ENGINEER, LICENSED IN THE PROVINCE/TERRITORY OFWORK. FOR EARTHQUAKE FORCES FOR LOCATIONS OUTSIDE OF THE PUBLISHED DATA, LOAD CONDITIONS SHALL BE CALCULATEDBY A QUALFIED PROFESSIONAL ENGINEER, LICENSED IN THE PROVINCE/TERRITORY OF WORK.
17. LIVE LOADING
EXTERNAL BALCONIES 4.8kPaINTERNAL STAIR AND LANDING 2.9kPa
FABRICATION DRAWINGS1. IT IS RECOMMENDED THAT A SITE SURVEY BE COMPLETED PRIOR TO FABRICATION.
2. SUBMIT PDF'S OF SHOP DRAWINGS FOR REVIEW BEFORE START OF WORK. PACKAGES TO BE SUBMITTED WILL BE AS PER THE CCGSTATEMENT OF WORK.
3. ALL FABRICATION DRAWINGS ARE TO BE REVIEWED BY THE CONTRACTOR FOR QUALITY ASSURANCE. REFER TO THE CANADIANCOAST GUARD STATEMENT OF WORK, AND STRUCTURAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
4. REVIEW OF FABRICATION DRAWINGS BY QUALIFIED CANADIAN COAST GUARD REPRESENTATIVE IS ON A SAMPLING BASIS, FORGENERAL CONFORMITY WITH STRUCTURAL CONTRACT DOCUMENTS AS REQUIRED BY STATEMENT OF WORK. IT IS NOT A DETAILEDCHECK AND MUST NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR OF HIS/HER RESPONSIBILITY TO MAKE THE WORKACCURATE AND IN CONFORMITY WITH ALL THE CONTRACT DOCUMENTS, TO REVIEW FABRICATION DRAWINGS AND TO COORDINATEWORK OF INTERFACING TRADES AND MANUFACTURE OF INTERFACING PRODUCTS.
5. REVIEW OF FABRICATION DRAWINGS DOES NOT IMPLY ANY CHANGE IN ANY OTHER CONSULTANTS' OR PROFESSIONALS'RESPONSIBILITIES RELATED TO DESIGN OF SPECIFIC ITEMS AS OUTLINED BY THESE DRAWINGS.
6. AFTER REVIEW, FABRICATION DRAWINGS WILL BE RETURNED. DO NOT COMMENCE FABRICATION UNTIL RETURNED FABRICATIONDRAWINGS HAVE BEEN EXAMINED.
FIELD REVIEW1. A QUALIFIED CANADIAN COAST GUARD REPRESENTATIVE WILL PROVIDE PERIODIC FIELD REVIEW OF A REPRESENTATIVE SAMPLE OF
THE STRUCTURAL WORKS DETAILED ON THESE DRAWINGS FOR GENERAL CONFORMANCE WITH CONTRACT DOCUMENTS. THESEREVIEWS DO NOT REPLACE THE BUILDER'S RESPONSIBILITY TO IMPLEMENT AND MAINTAIN A QUALITY CONTROL PROGRAM, AND DONOT MAKE STRUCTURAL CONSULTANT A GUARANTOR OF THE BUILDER'S WORK.
2. ASSIST THE QUALIFIED CANADIAN COAST GUARD REPRESENTATIVE DOING FIELD REVIEW, AND PROVIDE SAFE ACCESS TO WORKAREAS AS REQUIRED.
3. CHECK THE WORK PRIOR TO FIELD REVIEW TO CONFIRM IT IS COMPLETED AND IN ACCORDANCE WITH CONTRACT DOCUMENTS.
4. WSP-S IS NOT RESPONSIBLE FOR CONDUCTING FIELD REVIEW.
STRUCTURAL ALUMINUM1. CONFORM TO CSA S157-17 “STRENGTH DESIGN IN ALUMINUM”.
2. FABRICATOR TO BE CERTIFIED BY THE CANADIAN WELDING BUREAU UNDER REQUIREMENTS OF CSA W47.2-M1987 (R2008)CERTIFICATION OF COMPANIES FOR FUSION WELDING OF ALUMINUM
3. WELDERS TO BE CWB CERTIFIED, WELDING TO BE IN ACCORDANCE WITH CSA W59.2-M1991 (R2008) WELDED ALUMINUMCONSTRUCTION
4. MATERIALS CONFORM TO THE ALUMINUM ASSOCIATION PUBLICATION ALUMINUM STANDARDS AND DATA
- WIDE FLANGE SECTIONS, CHANNELS AND TUBES: GRADE ALUMINUM SERIES 6061-T6, MIN Fy = 240MPa- BOLTS, NUTS AND WASHERS SHALL BE A193 B8 CLASS 2.- ALUMINUM WELDING WIRE SHALL BE OF AN ALLOY CONFORMING TO THE ALUMINUM ASSOCIATION PUBLICATION ALUMINUM
STANDARDS AND DATA AND SHALL BE SELECTED ACCORDING TO CSA W59.2.- WELD FILLER MATERIAL TO BE 5183 AS PER CSA W59.2-18
5. FABRICATION DRAWINGS AND SUBMITTALS ARE TO BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE CANADIAN COAST GUARDSTATEMENT OF WORK, AND BE IN ACCORDANCE WITH ALL APPLICABLE CODE AND REGULATORY REQUIREMENTS.
6. CONNECT BEAMS FOR THE FORCES SHOWN ON DRAWINGS IF NO FORCE IS INDICATED, USE FULL STRENGTH CONNECTION.
7. WHERE MOMENT CONNECTIONS ARE CALLED FOR BUT VALUES ARE NOT INDICATED, DESIGN FOR MOMENT CAPACITY OF THESMALLER MEMBER IN THE CONNECTION.
8. WHERE SLOTTED CONNECTIONS ARE SHOWN ON STRUCTURAL DRAWINGS, FINGER TIGHTEN BOLTS TO A SNUG FIT AND BURRTHREADS TO PREVENT NUTS FROM WORKING LOOSE.
9. DO NOT SPLICE SECTIONS WITHOUT PRIOR ACCEPTANCE BY THE CONSULTANT AND SUBMISSION OF PERTINENT SHOP DRAWINGS.ACCEPTED SPLICES TO DEVELOP THE FULL MOMENT CAPACITY OF THE SECTION. EACH SPLICE TO BE GIVEN A NON-DESTRUCTIVETEST BY AN INDEPENDENT INSPECTION COMPANY ACCEPTABLE TO THE CANADIAN COAST GUARD. TESTING TO BE AT THECONTRACTOR'S EXPENSE. EVALUATE RESULTS IN ACCORDANCE WITH CSA W59 AND REPORT TO CANADIAN COAST GUARD.
10. DO NOT CUT HOLES OR OTHERWISE MODIFY STRUCTURAL MEMBERS ON SITE.
11. PROTECT COMBUSTIBLE MATERIALS AND FINISHES DURING WELDING OPERATIONS.
12. PROVIDE ALL ERECTION BRACING REQUIRED TO KEEP THE STRUCTURE STABLE AND IN ALIGNMENT DURING CONSTRUCTION.
13. ALL OPEN TUBE ENDS TO RECEIVE CAP PLATES.
INSPECTION AND TESTING1. INSPECTION AND TESTING TO BE IN ACCORDANCE WITH THE CANADIAN COAST GUARD STATEMENT OF WORK.
2. WSP-S IS NOT RESPONSIBLE FOR CONDUCTING THE CONSTRUCTION REVIEW.
REJECTED WORK1. DO NOT DELIVER MATERIALS WHICH ARE KNOWN NOT TO MEET THE REQUIREMENTS OF THE SPECIFICATIONS. IF REJECTED AFTER
DELIVERY, REMOVE IMMEDIATELY FROM SITE.
1
millimètresmillimeters
12111098754321056
CAD PRODUCED DRAWING
PRODUIT PAR DAO
4
A
B
D
Vendor Information / Sous-traitant
Pêches et Océans
Canada
Garde côtière
Canadienne
Fisheries and Oceans
Canada
Canadian
Coast Guard
C
23
scale - échelle
date
CCG ref. no. - no. réf. GCC
approved - approuvé
drawing no. - no. dessin sheet-feuille
designed - conception
date
drawn - dessiné
date
Asset - Actif
rev
by
datedescription
A1
Drawing - Dessin
rev-rév
par
checked - vérifié date
poucesinches
654210
REPORT ANY ERRORS OR OMISSIONS TO ILS MANAGER
SIGNALER LES ERREURS OU LES OMISSIONS AU GESTIONNAIRE SLI
File
/ F
ich
ie
r: 1
81
-1
59
56
-0
0_
AL
UM
IN
UM
L
IG
HT
HO
US
E - S
10
0E
.D
WG - Printed / Imprimé: 2
01
9/0
6/1
3 1
0:2
6
t. 613.829.2800
wsp.com
2611 Queensview Drive
Ottawa, ON Canada
Suite 300
K2B 8K2
f. 613.829.8299
CANADIAN COAST GUARD ALUMINIUM
LIGHTHOUSE MODULAR STRUCTURE
GARDE CÔTIÈRE CANADIENNE PHARE
EN ALUMINIUM, STRUCTURE MODULAIRE
GENERAL REQUIREMENTS
TDH
WDD
SLH
IJF
181-15956-00 N/A
S100E
S100E
S100E
01/09 0
TSH 2019/03/29
ISSUED FOR 100% DESIGN REVIEW
SOUMIS POUR RÉVISION DE
CONCEPTION 100%
TSH 2019/05/23
ISSUED FOR 100% DESIGN
SOUMIS POUR CONCEPTION 100%
TSH 2019/02/19
ISSUED FOR 60% REVIEW
SOUMIS POUR RÉVISION 60%
2
3
1
ISSUED FOR CONSTRUCTIONFOR CANADIAN COAST GUARD USE IN THE
INTENDED REGIONS ONLY
SOUMIS POUR CONSTRUCTIONPOUR L'UTILISATION DE LA GARDE COTIERE CANADIENNE
DANS LES REGIONS PREVUESSEULEMENT
DRAWING LISTDRAWINGNO. SHEET LISTS100E GENERAL REQUIREMENTS
S100F
EXIGENCES GÉNÉRALES
S200E BUILDING ELEVATIONS AND STRUCTURAL FRAMING ELEVATIONS
S200F
ÉLÉVATIONS DU BÂTIMENT ET ÉLÉVATIONS D'ENCADREMENT
STRUCTURAL
S201EPLANS, SECTIONS, & DETAILS
S201F PLANS, SECTIONS ET DÉTAILS
S202EELEVATIONS, SECTIONS AND DETAILS
S202F ÉLÉVATIONS, SECTIONS ET DÉTAILS
S400E BUILDING DETAILS
S400FDÉTAILS DE BÂTIMENT
Samer Jabbour
134865
GÉNÉRAL1. LE PROJET EST MÉTRIQUE SAUF INDICATION CONTRAIRE, TOUTES LES DIMENSIONS SONT EN MILLIMÈTRES.
2. TOUTES LES NORMES CITÉES EN RÉFÉRENCE SERONT BASÉES SUR L'ÉDITION EN VIGUEUR DE CELLE RÉFÉRENCÉE PAR LE CODE DUBÂTIMENT APPLICABLE ET EN VIGUEUR AU MOMENT DE LA DEMANDE DU PERMIS DE CONSTRUIRE.
3. LA MENTION « WSP-S » SIGNIFIE «CONSULTANT EN STRUCTURE DE WSP CANADA INC. ».
4. FOURNIR TOUS LES MATÉRIAUX ET LA MAIN-D'ŒUVRE REQUIS POUR LA RÉALISATION DES TRAVAUX.
5. AVANT LA CONSTRUCTION, RÉVISER LES DESSINS DE STRUCTURE DE CONCERT AVEC LES DESSINS FOURNIS PAR TOUS LES AUTRESCONSULTANTS AINSI QU'AVEC LES CONDITIONS EXISTANTES.
6. SIGNALER TOUTE ANOMALIE À LA GARDE CÔTIÈRE CANADIENNE AVANT DE COMMENCER LES TRAVAUX.
7. VÉRIFIER LES DIMENSIONS ET CONDITIONS EXISTANTES SUR PLACE AVANT LA CONSTRUCTION.
8. UTILISER CES DESSINS UNIQUEMENT AUX FINS SPÉCIFIÉES DANS LA COLONNE DES RÉVISIONS. NE PAS CONSTRUIRE À PARTIR DECES PLANS À MOINS QU'ILS NE SOIENT ÉMIS AVEC L'ÉNONCÉ DES TRAVAUX DE LA PART DE LA GARDE CÔTIÈRE CANADIENNE. WSPNE SERA PAS TENU RESPONSABLE DE QUELCONQUES CHANGEMENTS ET/OU MODIFICATIONS DE CES PLANS. TOUTES LESRESPONSABILITÉS RÉSULTANTES DE CES CHANGEMENTS/MODIFICATIONS SERONT L'ENTIÈRE RESPONSABILITÉ DEL'ENTREPRENEUR, LA GARDE CÔTIÈRE CANADIENNE ET TOUTES AUTRES PARTIES RESPONSABLE DESMODIFICATIONS/CHANGEMENTS. WSP NE SERA PAS RESPONSABLE DE LA CONSTRUCTION DE L'OUVRAGE NI DE L'ADMINISTRATIONDES CONTRATS LORS DE LA CONSTRUCTION.
9. NE PAS UTILISER L'INFORMATION DE CES DESSINS POUR TOUT AUTRE PROJET OU TRAVAUX.
10. NE PAS MESURER À L'ÉCHELLE SUR LES DESSINS.
11. TOUTES LES COUPES, TOUS LES DÉTAILS ET TOUS LES ÉNONCÉS QUALIFIÉS COMME « TYPIQUES » S'APPLIQUENT À DESCONDITIONS IDENTIQUES/ANALOGUES DANS LA STRUCTURE.
12. LES DESSINS PRÉSENTENT UNIQUEMENT UNE STRUCTURE ACHEVÉE. ILS NE MONTRENT PAS LES TRAVAUX TEMPORAIRES POURLESQUELS L'ENTREPRENEUR EST RESPONSABLE ET QUI PEUVENT ÊTRE REQUIS POUR LA RÉALISATION DU PROJET.L'ENTREPRENEUR DOIT ÉTABLIR LA PROCÉDURE ET LA SÉQUENCE DE CONSTRUCTION POUR ASSURER LA SÉCURITÉ DE L'ENSEMBLEDE LA STRUCTURE ET DE TOUS SES COMPOSANTS PENDANT L'ÉRECTION.
13. PRENDRE LES DISPOSITIONS NÉCESSAIRES POUR TOUTES LES CHARGES AGISSANT SUR LA STRUCTURE EN COURS DE MONTAGE.FOURNIR L'ÉTAYAGE ET LE CONTREVENTEMENT TEMPORAIRES POUR MAINTENIR LA STRUCTURE D'APLOMB ET PARFAITEMENTALIGNÉE PENDANT LA CONSTRUCTION.
14. LA CONCEPTION ET L'ATTESTATION DE CONFORMITÉ D'EXÉCUTION DE TOUS LES TRAVAUX TEMPORAIRES DOIVENT ÊTREEFFECTUÉES PAR UN INGÉNIEUR ENGAGÉ PAR L'ENTREPRENEUR ET AUTORISÉ À EXERCER DANS LE LIEU OÙ LE PROJET EST SITUÉ.
15. LES CHARGES DE CONSTRUCTION SUR LA STRUCTURE ACHEVÉE NE DOIVENT PAS EXCÉDER LES CHARGES DE CONCEPTIONINDIQUÉES AUX DESSINS.
16. PAR «UN REPRÉSENTANT QUALIFIÉ DE LA GARDE CÔTIÈRE CANADIENNE» DANS CES DOCUMENTS, IL EST ENTENDU UNE PERSONNEPOSSÉDANT LA FORMATION PROFESSIONNELLE NÉCESSAIRE CONFORMÉMENT À TOUS LES CODES, NORMES ET RÈGLEMENTSACTUELS.
DONNÉES DE CONCEPTION1. LA CONCEPTION STRUCTURALE EST CONFORME AU CODE NATIONAL DU BÂTIMENT (CNB) 2015, COMPLÉTÉE PAR LES
COMMENTAIRES SUR LE CALCUL DES STRUCTURES ANNEXÉS AU CODE NATIONAL DU BÂTIMENT DU CANADA2015.
2. LA CONCEPTION EST AUSSI COMPLÉTÉE PAR LES CODES ET RÈGLEMENTS SUIVANTS:- CODE NATIONAL DU BÂTIMENT (CNB) 2015- CODE CANADIEN DU TRAVAIL (R.S.C., 1985, c. L-2)- RÈGLEMENTS CANADIEN SUR LA SURETÉ AÉRIENNE - 2017 PART III- CSA S16-14 RÈGLES DE CALCUL DES CHARPENTES EN ACIER- CSA O86-14 RÈGLES DE CALCUL DES CHARPENTES EN BOIS- CSA S157-17 CALCUL DE LA RÉSISTANCE MÉCANIQUE DES ÉLÉMENTS EN ALUMINIUM- CSA W47.2-11 (R2015), CERTIFICATION DES COMPAGNIES DE SOUDAGE PAR FUSION DE L'ALUMINIUM- CSA W59.2-18, CONSTRUCTION SOUDÉE EN ALUMINIUM- CAN/CGSB-48.9217-2006/ISO 9712:2005 ESSAIS NON DESTRUCTIFS -- QUALIFICATION ET CERTIFICATION DU
PERSONNEL END.- ACSE 7-16 CHARGES MINIMUM DE CONCEPTION POUR LES BÂTIMENTS ET AUTRES STRUCTURES- ASTM B209M-14, SPÉCIFICATION STANDARD POUR TÔLES ET PLAQUES EN ALUMINIUM ET EN ALLIAGE D'ALUMINIUM.- ASTM B308M-10, SPÉCIFICATION STANDARD POUR ALLIAGE D'ALUMINIUM 6061-T6 PROFILS STANDARDS
STRUCTURELS.- ASTM A193/A193M-17, SPÉCIFICATION STANDARD POUR ALLIAGE D'ACIER ET BOULONNERIE EN ACIER INOXYDABLE
POUR HAUTE TEMPÉRATURE OU SERVICE À HAUTE PRESSION ET D'AUTRES APPLICATIONS À USAGE SPÉCIAL.- AWS A5.10/A5.10M (2017), SPÉCIFICATION POUR LES TIGES ET ÉLECTRODES DE SOUDAGE D'ALUMINIUM ET
D'ALLIAGE D'ALUMINIUM.
3. TOUTES LES NORMES CITÉES EN RÉFÉRENCE SERONT BASÉES SUR L'ÉDITION EN VIGUEUR DE CELLE RÉFÉRENCÉE PAR LE CODE DUBÂTIMENT APPLICABLE ET EN VIGUEUR AU MOMENT DE LA DEMANDE DU PERMIS DE CONSTRUIRE.
4. LES VALEURS DES DONNÉES CLIMATIQUES UTILISÉES DANS LA DÉTERMINATION DES CHARGES DE CALCUL ONT ÉTÉ OBTENUES ÀPARTIR DU CNB 2015 POUR LA LOCALITÉ DE L'ONTARIO, DU QUÉBEC ET DU NUNAVUT. LA MUNICIPALITÉ QUI PRÉSENTE LES CHARGESDE CONCEPTIONS DE NEIGE, VENT & SISMIQUE LES PLUS CONSERVATIVES A ÉTÉ CHOISIE COMME FONDEMENT POUR LACONCEPTION. POUR LES EMPLACEMENTS DE SITE ÉLOIGNÉS DE PLUS DE 50km DE L'EMPLACEMENT LE PLUS PROCHE ÉNUMÉRÉDANS LES DONNÉES PUBLIÉES DANS LE CNB 2015, LES CONDITIONS DE CHARGEMENT DOIVENT ÊTRES RÉVISÉES PAR UN INGÉNIEURPROFESSIONNEL QUALIFIÉ, AUTORISÉ À TRAVAILLER DANS LE TERRITOIRE/PROVINCE DE L'OUVRAGE. POUR LES FORCES SISMIQUESDES EMPLACEMENTS EN DEHORS DES DONNÉES PUBLIÉES, LES CONDITIONS DE CHARGEMENTS DOIVENT ÊTRE CALCULÉES PAR UNINGÉNIEUR PROFESSIONNEL QUALIFIÉ, AUTORISÉ À TRAVAILLER DANS LE TERRITOIRE/PROVINCE DE L'OUVRAGE.
5. BASÉ SUR L'USAGE ET L'OCCUPATION, LE BÂTIMENT EST CONÇU SELON LES EXIGENCES DE LA CATÉGORIE DE RISQUE FAIBLE.
6. LE POIDS PROPRE (SWT) REPRÉSENTE LE POIDS DE LA STRUCTURE ELLE-MÊME. IL VARIE SELON LE SYSTÈME STRUCTURAL.
7. LES CHARGES MORTES ADDITIONNELLES (DADD) (SDL) SONT DES CHARGES PERMANENTES NON STRUCTURALES EN RAISON DESCHAPES, REVÊTEMENTS, CLOISONS, MATÉRIAUX DE TOITURE, ÉQUIPEMENTS SUSPENDUS, PAVÉS, TERRE ET AUTRES MATÉRIAUXNON PORTANTS.
8. LA CHARGE PERMANENTE (DL) EST LE POIDS PROPRE DE LA STRUCTURE PLUS LA CHARGE MORTE ADDITIONNELLE.
9. SAUF INDICATION CONTRAIRE, LES CHARGES DE CALCUL INDIQUÉES SUR LES DESSINS SONT NON PONDÉRÉES, ET INDIQUÉES AUXFINS DE CALCUL AUX ÉTATS LIMITES. POUR LE CALCUL DES ÉTATS LIMITES DE SERVICE (ÉLTS), CES CHARGES PEUVENT ÊTRERÉDUITES EN MULTIPLIANT PAR LE RATIO DES FACTEURS D'IMPORTANCE APPROPRIÉS Ix(SLS)/Ix(ULS) INDIQUÉS CI-DESSOUS.
10. SI UNE SEULE VALEUR EST DONNÉE POUR UNE CHARGE, ELLE DOIT ÊTRE CONSIDÉRÉE COMME UNE CHARGE VIVE.
11. POUR LES CHARGES DE CONNEXION, LE SIGNE « + » INDIQUE LA TENSION ET LE SIGNE « -» INDIQUE LA COMPRESSION, SAUF POURLES CHARGES DES POTEAUX OÙ LE SIGNE « + » INDIQUE LA COMPRESSION ET LE SIGNE « - » LA TENSION.
12. NEIGE: (CHARGE DE NEIGE MAX POUR CHAQUE RÉGION)
LES TROIS RÉGIONS SÉLECTIONNÉES CI-DESSOUS REPRÉSENTENT LE PIRE CAS DE DONNÉES CLIMATIQUES POUR CHAQUEPROVINCE/TERRITOIRE, ELLES GÉNÈRENT LE PLUS GRAND CHARGEMENT DE VENT ET NEIGE COMBINÉ.
1. QUÉBEC (HARRINGTON HARBOUR)1. Ss = 4.9 kPa; Sr = 0.6 kPa; Is (ULS) = 0.8; Is (SLS) = 0.9
2. NUNAVUT (NOTTINGHAM ISLAND)1. Ss = 4.7 kPa; Sr = 0.2 kPa; Is (ULS) = 0.8; Is (SLS) = 0.9
3. ONTARIO (CHAPLEAU)1. Ss = 3.6 kPa; Sr = 0.4 kPa; Is (ULS) = 0.8; Is (SLS) = 0.9
LA CHARGE DE NEIGE SPÉCIFIQUE EST CALCULÉE COMME S = Is[SsCbCsCa + Sr]OÙ Cb = 0.8, Cw = 1.0, Cs = 1.0 & Ca = 1.0
AINSI POUR LA PLUS GRANDE CHARGE DE NEIGE - QUÉBEC (HARRINGTON HARBOUR) S = 3.6kPa
13. PLUIE: 24 HEURES DE PLUIE1. QUÉBEC (HARRINGTON HARBOUR) = 96 mm2. NUNAVUT (NOTTINGHAM ISLAND) = 54 mm3. ONTARIO (CHAPLEAU) = 97 mm
14. LES CHARGES LATÉRALES DANS CETTE STRUCTURE SONT REPRISES PAR LES CADRES CONTREVENTÉS, ET SONT DÉTERMINÉES ENFONCTION DES DONNÉES SISMIQUES ET DE VENT CI-DESSOUS.
15. VENT:
1. QUÉBEC (HARRINGTON HARBOUR) q50 = 0.72 kPa; Iw (ULS) = 0.8; Iw (SLS) = 0.752. NUNAVUT (NOTTINGHAM ISLAND) q50 = 0.78 kPa; Iw (ULS) = 0.8; Iw (SLS) = 0.753. ONTARIO (CHAPLEAU) q50 = 0.30 kPa; Iw (ULS) = 0.8; Iw (SLS) = 0.75
NOTE : POUR LA RÉGION DE L'ONTARIO, L'EMPLACEMENT DE LA CHARGE DE NEIGE MAXIMALE NE CORRESPOND PAS À CELLE DE LACHARGE DE VENT MAXIMALE (PORT ELGIN q50 =0.55kPa), AFIN DE S'ASSURER QUE LA CONCEPTION SERA APPLICABLE AUX TROISPROVINCES/TERRITOIRES, LA PLUS GRANDE CHARGE DE VENT q50 = 0.78kPa A ÉTÉ UTILISÉE POUR LES CALCULS DE CHARGES DEVENT.
TYPE DE TERRAIN: TERRAIN ORDINAIRE (h/10)0.2 >= 0.9
CHARGE DE VENT - SELON LA PARTIE 4 DU CNB 2015
p = IwqCeCtCgCp Iw = 0.8 (FAIBLE)= (0.8)(0.78)(0.93)(3.255)(2.0)(0.8) q = 0.78 (NUNAVUT, NOTTINGHAM ISLAND, PLUS GRANDE VALEUR DES 3 RÉGIONS)
= 3.02 kPa (AU VENT) Ce = 0.93Ct = 3.255 (VALEUR MAXIMALE D'ACCÉLÉRATION DU VENT À L'ESCARPEMENT)
= (0.8)(0.78)(0.93)(3.255)(2.0)(-0.5) Cg = 2.0 = 1.89 kPa (SOUS LE VENT) Cp = 0.8 (AU VENT), -0.5 (SOUS LE VENT)
16. SISMIQUE
LES TROIS RÉGIONS SÉLECTIONNÉES CI-DESSOUS REPRÉSENTENT LES DONNÉES SISMIQUES LES PLUS CRITIQUES DE CHAQUEPROVINCE.
QUÉBEC (LA-MALBAIE)Sa (0.2) = 1.73 IeFaSa(0.2) = 1.38Sa (0.5) = 0.954 (SITE DE CLASSE C)Sa(1.0) = 0.454Sa(2.0) = 0.203PGA = 1.04
NUNAVUT (CLYDE RIVER)Sa (0.2) = 0.306 IeFaSa(0.2) = 0.30Sa (0.5) = 0.186 (SITE DE CLASSE E)Sa(1.0) = 0.104Sa(2.0) = 0.053PGA = 0.195
ONTARIO (ALEXANDRIA)Sa (0.2) = 0.589 IeFaSa(0.2) = 0.45Sa (0.5) = 0.309 (SITE DE CLASSE E)Sa(1.0) = 0.148Sa(2.0) = 0.068PGA = 0.376
IE = 0.8 (IMPORTANCE: FAIBLE)Rd = 1.5Ro = 1.3CLASSE DU SITE = ESYSTÈME DE RÉSISTANCE AUX FORCES SISMIQUES (SRFS): CADRES CONTREVENTÉS
TYPE DE CHARGES DECONCEPTION
VALEURS MAXIMALES DE CONCEPTION RÉGION/TERRITOIRE GOUVERNANT
NEIGE 3.6kPa QUÉBEC (HARRINGTON HARBOUR)
VENT (PHARE AU VENT/ SOUSLE VENT)
3.02kPa/1.89kPa NUNAVUT (NOTTINGHAM ISLAND)
SISMIQUE IeFaSa(0.2) = 1.38 (SITE DE CLASSE C)S QUÉBEC (LA-MALBAIE)
POUR LES EMPLACEMENTS DE SITE ÉLOIGNÉS DE PLUS DE 50km DE L'EMPLACEMENT LE PLUS PROCHE ÉNUMÉRÉ DANS LESDONNÉES PUBLIÉES DANS LE CNB 2015, LES CONDITIONS DE CHARGEMENT DOIVENT ÊTRES RÉVISÉES PAR UN INGÉNIEURPROFESSIONNEL QUALIFIÉ, AUTORISÉ À TRAVAILLER DANS LE TERRITOIRE/PROVINCE DE L'OUVRAGE. POUR LES FORCES SISMIQUESDES EMPLACEMENTS EN DEHORS DES DONNÉES PUBLIÉES, LES CONDITIONS DE CHARGEMENTS DOIVENT ÊTRE CALCULÉES PAR UNINGÉNIEUR PROFESSIONNEL QUALIFIÉ, AUTORISÉ À TRAVAILLER DANS LE TERRITOIRE/PROVINCE DE L'OUVRAGE.
17. CHARGE VIVE
BALCONS EXTÉRIEURS 4.8kPaESCALIERS INTÉRIEURS ET ZONE D'ATTÉRISSAGE 2.9kPa
DESSINS DE FABRICATION1. IL EST RECOMMANDÉ DE COMPLÉTER UNE ÉVALUATION DES LIEUX AVANT LA FABRICATION.
2. SOUMETTRE POUR EXAMEN UN FICHIER EN FORMAT PDF DES DESSINS DE FABRICATION AVANT LE DÉBUT DES TRAVAUX. LESDESSINS DE FABRICATION/FICHES TECHNIQUES DEVANT ÊTRE SOUMIS SERONT CONFORMES AUX EXIGENCES DE L'ÉNONCÉ DESTRAVAUX DE LA GARDE CÔTIÈRE CANADIENNE.
3. TOUS LES DESSINS DE FABRICATION DOIVENT ÊTRE VÉRIFIÉS PAR L'ENTREPRENEUR À DES FINS D'ASSURANCE QUALITÉ. VOIRL'ÉNONCÉ DES TRAVAUX DE LA GARDE CÔTIÈRE CANADIENNE, ET PLANS DE STRUCTURE ET NOTES POUR LES EXIGENCESADDITIONNELLES.
4. L'EXAMEN DES DESSINS DE FABRICATION PAR UN REPRÉSENTANT QUALIFIÉ DE LA GARDE CÔTIÈRE CANADIENNE EST FAIT AFIN D'ENASSURER LA CONFORMITÉ GÉNÉRALE AVEC LES DOCUMENTS CONTRACTUELS DE STRUCTURE TEL QUE REQUIS PAR L'ÉNONCÉ DESTRAVAUX. CETTE VÉRIFICATION N'EST PAS UN CONTRÔLE EXHAUSTIF ET NE DOIT PAS ÊTRE INTERPRÉTÉE COMME LIBÉRANTL'ENTREPRENEUR DE SA RESPONSABILITÉ À RENDRE UN OUVRAGE COMPLET ET CONFORME À TOUS LES DOCUMENTSCONTRACTUELS, À RÉVISER LES DESSINS DE FABRICATION AINSI QU'À ASSURER LA COORDINATION DES TRAVAUX ET LAFABRICATION DES PRODUITS AVEC LES DIFFÉRENTS CORPS DE MÉTIER IMPLIQUÉS.
5. L'EXAMEN DES DESSINS DE FABRICATION N'IMPLIQUE AUCUNE MODIFICATION AUX RESPONSABILITÉS DE TOUT AUTRE CONSULTANTOU PROFESSIONNEL RELATIVES À LA CONCEPTION D'ÉLÉMENTS SPÉCIFIQUES TELS QUE CEUX DÉFINIS PAR CES DESSINS.
6. APRÈS EXAMEN, LES DESSINS SERONT RETOURNÉS. LA FABRICATION NE DOIT PAS COMMENCER AVANT QUE LES DESSINS DEFABRICATION RETOURNÉS N'AIENT ÉTÉ RÉVISÉS.
INSPECTION DES TRAVAUX1. UN REPRÉSENTANT QUALIFIÉ DE LA GARDE CÔTIÈRE CANADIENNE EFFECTUERA PÉRIODIQUEMENT DES VISITES DE CHANTIER AFIN
DE VALIDER LA CONFORMITÉ GÉNÉRALE DES TRAVAUX AVEC LES PRÉSENTS DESSINS ET AUTRES DOCUMENTS CONTRACTUELS.CES VISITES NE REMPLACENT PAS LA RESPONSABILITÉ DE L'ENTREPRENEUR À METTRE EN ŒUVRE ET À MAINTENIR UN PROGRAMMEDE CONTRÔLE DE LA QUALITÉ ET NE RENDENT PAS WSP-S GARANT DES TRAVAUX EFFECTUÉS PAR L'ENTREPRENEUR.
2. ACCOMPAGNER LE REPRÉSENTANT QUALIFIÉ DE LA GARDE CÔTIÈRE CANADIENNE LORS DES VISITES DE CHANTIER ET FOURNIR UNACCÈS SÉCURITAIRE AUX ZONES DE TRAVAIL, SELON LES BESOINS.
3. VÉRIFIER QUE L'OUVRAGE A ÉTÉ EFFECTUÉ ET QU'IL EST CONFORME AUX DOCUMENTS CONTRACTUELS AVANT LA VISITED'INSPECTION AU CHANTIER.
4. WSP-S N'EST PAS RESPONSABLE D'EFFECTUER DES VISITES DE CHANTIER.
ALUMINIUM STRUCTURAL1. CONFORME À LA NORME CSA S157-17 “CALCUL DE LA RÉSISTANCE MÉCANIQUE DES ÉLÉMENTS EN ALUMINIUM”.
2. LE FABRICANT DOIT ÊTRE CERTIFIÉ PAR LE BUREAU CANADIEN DE SOUDAGE, SELON LES EXIGENCES DE LA NORME CSA W47.2-M1987(R2008) CERTIFICATION DES COMPAGNIES DE SOUDAGE PAR FUSION DE L'ALUMINIUM.
3. LES SOUDEURS DOIVENT AVOIR LA CERTIFICATION CWB. LE SOUDAGE DOIT ÊTRE CONFORME À LA NORME CSA W59.2-M1991 (R2008)CONSTRUCTION SOUDÉE EN ALUMINIUM.
4. MATÉRIAUX CONFORMES À LA PUBLICATION DE L'ASSOCIATION D'ALUMINIUM NORMES ET DONNÉES SUR L'ALUMINIUM :
- PROFILÉS À AILES LARGES, PROFILÉS ET SECTIONS TUBULAIRES: NUANCE D'ALUMINIUM SÉRIES 6061-T6, MIN Fy = 240MPa.- BOULONS, ÉCROUS ET RONDELLES DOIVENT ÊTRE DE CLASSE 2 A193 B8.- FIL DE SOUDAGE D'ALUMINIUM DOIT ÊTRE D'UN ALLIAGE CONFORME À LA PUBLICATION DE L'ASSOCIATION D'ALUMINIUM
NORMES ET DONNÉES SUR L'ALUMINIUM ET DOIT ÊTRE SÉLECTIONNÉ SELON LA NORME CSA W59.2.- MATÉRIAU DE SOUDAGE DE TYPE 5183 CONFORME À LA NORME CSA W59.2-18
5. LES DESSINS D'ATELIER ET LES SOUMISSIONS DOIVENT ÊTRE CONFORMES AUX EXIGENCES DE L'ÉNONCÉ DES TRAVAUX DE LAGARDE CÔTIÈRE CANADIENNE, ET ÊTRE CONFORMES À TOUS LES CODES, NORMES ET EXIGENCES EN VIGUEUR.
6. DIMENSIONNER LES ASSEMBLAGES DES POUTRES SELON LES EFFORTS INDIQUÉS SUR LES DESSINS SI AUCUN EFFORT N'ESTINDIQUÉ, UTILISER DES CONNEXIONS POUR PLEINE CAPACITÉ.
7. LORSQUE DES ASSEMBLAGES RÉSISTANTS AUX MOMENTS DE FLEXION SONT DEMANDÉS, MAIS QUE LES EFFORTS NE SONT PASINDIQUÉS, CALCULER ET EXÉCUTER SELON LA RÉSISTANCE EN FLEXION DU PLUS PETIT ÉLÉMENT DE L'ASSEMBLAGE.
8. LORSQUE DES CONNEXIONS OVALISÉES SONT INDIQUÉES SUR LES DESSINS DE STRUCTURE, SERRER LES BOULONS À LA MAINJUSQU'À L'OBTENTION D'UN BON AJUSTEMENT ET ÉBARBER LES FILETS POUR ÉVITER QUE L'ÉCROU SE DESSERRE.
9. NE PAS RÉALISER D'ÉPISSURES DANS LES SECTIONS SANS AVOIR OBTENU AU PRÉALABLE L'ACCEPTATION DU CONSULTANT ET SANSAVOIR SOUMIS LES DESSINS D'ATELIER PERTINENTS. LES ÉPISSURES ACCEPTÉES DOIVENT DÉVELOPPER LA CAPACITÉ EN FLEXIONDE LA SECTION. CHAQUE ÉPISSURE DOIT ÊTRE INSPECTÉE PAR UN LABORATOIRE INDÉPENDANT ACCEPTABLE POUR LA GARDECÔTIÈRE CANADIENNE. L'INSPECTION SERA EFFECTUÉE AUX FRAIS DE L'ENTREPRENEUR. ÉVALUER LES RÉSULTATS SELON LANORME CSAW59 ET SOUMETTRE LE RAPPORT À LA GARDE CÔTIÈRE CANADIENNE.
10. NE PAS PERCER DE TROUS OU MODIFIER DE QUELQUE FAÇON LES ÉLÉMENTS DE STRUCTURE SUR LE CHANTIER.
11. PROTÉGER LES MATÉRIAUX ET LES REVÊTEMENTS COMBUSTIBLES LORS DES OPÉRATIONS DE SOUDAGE.
12. FOURNIR TOUS LES CONTREVENTEMENTS TEMPORAIRES REQUIS POUR MAINTENIR LA STRUCTURE STABLE ET ALIGNÉE TOUT AULONG DE LA CONSTRUCTION.
13. FOURNIR DES PLAQUES DE FERMETURE À TOUTES LES EXTRÉMITÉS DES SECTIONS TUBULAIRES OUVERTES.
INSPECTION ET ESSAIS1. L'INSPECTION ET LES ESSAIS DOIVENT RÉPONDRE AUX EXIGENCES DE L'ÉNONCÉ DES TRAVAUX DE LA GARDE CÔTIÈRE
CANADIENNE.
2. WSP-S N'EST PAS RESPONSABLE D'EFFECTUER L'EXAMEN DE LA CONSTRUCTION.
MATÉRIEL REFUSÉ1. NE PAS LIVRER DES MATÉRIAUX QUI NE RÉPONDENT PAS AUX EXIGENCES DES PRÉSENTES NOTES GÉNÉRALES. SI REFUSÉ APRÈS
LA LIVRAISON, RETIRER IMMÉDIATEMENT DU CHANTIER.
1
millimètresmillimeters
12111098754321056
CAD PRODUCED DRAWING
PRODUIT PAR DAO
4
A
B
D
Vendor Information / Sous-traitant
Pêches et Océans
Canada
Garde côtière
Canadienne
Fisheries and Oceans
Canada
Canadian
Coast Guard
C
23
scale - échelle
date
CCG ref. no. - no. réf. GCC
approved - approuvé
drawing no. - no. dessin sheet-feuille
designed - conception
date
drawn - dessiné
date
Asset - Actif
rev
by
datedescription
A1
Drawing - Dessin
rev-rév
par
checked - vérifié date
poucesinches
654210
REPORT ANY ERRORS OR OMISSIONS TO ILS MANAGER
SIGNALER LES ERREURS OU LES OMISSIONS AU GESTIONNAIRE SLI
File
/ F
ich
ie
r: 1
81
-1
59
56
-0
0_
AL
UM
IN
UM
L
IG
HT
HO
US
E - S
10
0F
.D
WG - Printed / Imprimé: 2
01
9/0
6/1
3 1
0:2
6
t. 613.829.2800
wsp.com
2611 Queensview Drive
Ottawa, ON Canada
Suite 300
K2B 8K2
f. 613.829.8299
CANADIAN COAST GUARD ALUMINIUM
LIGHTHOUSE MODULAR STRUCTURE
GARDE CÔTIÈRE CANADIENNE PHARE
EN ALUMINIUM, STRUCTURE MODULAIRE
EXIGENCES GÉNÉRALES
TDH
WDD
SLH
IJF
181-15956-00 N/A
S100F
S100F
S100F
01/09 0
TSH 2019/03/29
ISSUED FOR 100% DESIGN REVIEW
SOUMIS POUR RÉVISION DE
CONCEPTION 100%
TSH 2019/05/23
ISSUED FOR 100% DESIGN
SOUMIS POUR CONCEPTION 100%
TSH 2019/02/19
ISSUED FOR 60% REVIEW
SOUMIS POUR RÉVISION 60%
2
3
1
ISSUED FOR CONSTRUCTIONFOR CANADIAN COAST GUARD USE IN THE
INTENDED REGIONS ONLY
SOUMIS POUR CONSTRUCTIONPOUR L'UTILISATION DE LA GARDE COTIERE CANADIENNE
DANS LES REGIONS PREVUESSEULEMENT
DRAWING LISTDRAWINGNO. SHEET LISTS100E GENERAL REQUIREMENTS
S100F
EXIGENCES GÉNÉRALES
S200E BUILDING ELEVATIONS AND STRUCTURAL FRAMING ELEVATIONS
S200F
ÉLÉVATIONS DU BÂTIMENT ET ÉLÉVATIONS D'ENCADREMENT
STRUCTURAL
S201EPLANS, SECTIONS, & DETAILS
S201F PLANS, SECTIONS ET DÉTAILS
S202EELEVATIONS, SECTIONS AND DETAILS
S202F ÉLÉVATIONS, SECTIONS ET DÉTAILS
S400E BUILDING DETAILS
S400FDÉTAILS DE BÂTIMENT
Samer Jabbour
134865
8153
610 610 610 610610EQ. EQ.
610 610EQ.
610610EQ.
533 533 1041EQ.
610 610EQ.
610610EQ.
533533EQ.
762x2000 CLEAR OPENING FOR
ACCESS DOOR. FRAME WITH
HSS102x102x4.8 MEMBERS
WALKWAY FRAMING,
REFER TO S201
WALKWAY FRAMING,
REFER TO S201
HSS102x102x4.8
762 x 2000 CLEAR
OPENING
610 610 610 610610EQ. EQ.
610EQ.
610EQ.
1068
610 610 610 610610EQ. EQ.
610EQ.
610EQ.
1068
MO
DU
LA
R S
EC
TIO
N 1
2540
MO
DU
LA
R S
EC
TIO
N 2
2184
MO
DU
LA
R S
EC
TIO
N 3
4369
MO
DU
LA
R S
EC
TIO
N 1
2540
MO
DU
LA
R S
EC
TIO
N 2
2184
1
S202E
1
S202E
H
S202E
G
S202E
G
S202E
H
S202E
ULS
UPLIFT -30kN
DOWN +68kN
AXIAL
SLS
UPLIFT -15kN
DOWN +51kN
HORIZONTAL
ULS +30kN
SLS +21kN
ULS
UPLIFT -10kN
DOWN +23kN
AXIAL
SLS
UPLIFT -5kN
DOWN +17kN
HORIZONTAL
ULS ±10kN
SLS ±7kN
TYPICAL INTERNAL
POST REACTION
ULS
AXIAL
SLS
HORIZONTAL
ULS
AXIAL
SLS
HORIZONTAL
TYPICAL INTERNAL
POST REACTION
ULS
AXIAL
SLS
HORIZONTAL
ULS
AXIAL
SLS
HORIZONTAL
ULS
AXIAL
SLS
HORIZONTAL
TYPICAL INTERNAL
POST REACTION
ULS
AXIAL
SLS
HORIZONTAL
TYPICAL INTERNAL
POST REACTION
UPLIFT -30kN
DOWN +68kN
UPLIFT -15kN
DOWN +51kN
UPLIFT -30kN
DOWN +68kN
UPLIFT -15kN
DOWN +51kN
UPLIFT -30kN
DOWN +68kN
UPLIFT -15kN
DOWN +51kN
UPLIFT -10kN
DOWN +23kN
UPLIFT -5kN
DOWN +17kN
UPLIFT -10kN
DOWN +23kN
UPLIFT -5kN
DOWN +17kN
UPLIFT -10kN
DOWN +23kN
UPLIFT -5kN
DOWN +17kN
ULS +30kN
SLS +21kN
ULS ±10kN
SLS ±7kN
ULS ±30kN
SLS ±21kN
ULS ±10kN
SLS ±7kN
ULS ±10kN
SLS ±7kN
ULS +30kN
SLS +21kN
HSS102x102x6.4
HSS102x102x6.4
HSS102x102x4.8 HSS102x102x4.8
MO
DU
LA
R S
EC
TIO
N 3
4369
WALKWAY FRAMING,
REFER TO S201
HSS102x102x4.8
HSS102x102x4.8
500 500 500EQ.EQ.
1249
2180
J
S202E
EQ.EQ. EQ.EQ.
1
S202E
1
S202E
ROOF BY CCG, TYP.
MAXIMUM WEIGHT
OF 500kg
CLADDING TO DETAIL
ON S400
1249
2180
1871
500 500 500EQ.EQ.
8153
±4532 SQUARE
3594 SQUARE
2753 SQUARE
1871
SQUARE
500 500 500EQ.EQ.
500 500 500EQ.EQ.
1100 TYP
1871
18711871
585
585
MAXIMUM CLADDING
SDL = 0.2kPa
IF HSS152x102x6.4 IS TRIMMED
AFTER INSTALLATION TO
PREVENT TRIPPING HAZARD,
INSTALL ADDITIONAL ANCHORS
AT ENDS OF CUT
430
SCALE 1:50
0.5 1 2
1
millimètresmillimeters
12111098754321056
CAD PRODUCED DRAWING
PRODUIT PAR DAO
4
A
B
D
Vendor Information / Sous-traitant
Pêches et Océans
Canada
Garde côtière
Canadienne
Fisheries and Oceans
Canada
Canadian
Coast Guard
C
23
scale - échelle
date
CCG ref. no. - no. réf. GCC
approved - approuvé
drawing no. - no. dessin sheet-feuille
designed - conception
date
drawn - dessiné
date
Asset - Actif
rev
by
datedescription
A1
Drawing - Dessin
rev-rév
par
checked - vérifié date
poucesinches
654210
REPORT ANY ERRORS OR OMISSIONS TO ILS MANAGER
SIGNALER LES ERREURS OU LES OMISSIONS AU GESTIONNAIRE SLI
File
/ F
ich
ie
r: 1
81
-1
59
56
-0
0_
AL
UM
IN
UM
L
IG
HT
HO
US
E - S
20
0.D
WG - Printed / Imprimé: 2
01
9/0
6/1
3 1
0:2
6
t. 613.829.2800
wsp.com
2611 Queensview Drive
Ottawa, ON Canada
Suite 300
K2B 8K2
f. 613.829.8299
CANADIAN COAST GUARD ALUMINIUM
LIGHTHOUSE MODULAR STRUCTURE
GARDE CÔTIÈRE CANADIENNE PHARE
EN ALUMINIUM, STRUCTURE MODULAIRE
BUILDING ELEVATIONS AND
STRUCTURAL FRAMING
ELEVATIONS
TDH
WDD
SLH
IJF
181-15956-00 N/A
S200E
S200E
S200E
01/09 0
TSH 2019/03/29
ISSUED FOR 100% DESIGN REVIEW
SOUMIS POUR RÉVISION DE
CONCEPTION 100%
TSH 2019/05/23
ISSUED FOR 100% DESIGN
SOUMIS POUR CONCEPTION 100%
TSH 2019/02/19
ISSUED FOR 60% REVIEW
SOUMIS POUR RÉVISION 60%
2
3
1
ISSUED FOR CONSTRUCTIONFOR CANADIAN COAST GUARD USE IN THE
INTENDED REGIONS ONLY
SOUMIS POUR CONSTRUCTIONPOUR L'UTILISATION DE LA GARDE COTIERE CANADIENNE
DANS LES REGIONS PREVUESSEULEMENT
Samer Jabbour
134865
8153
610 610 610 610610
ÉG ÉG
610 610
ÉG
610610
ÉG
533 533 1041
ÉG
610 610
ÉG
610610
ÉG
533533
ÉG
OUVERTURE 762x2000 POUR PORTE
D'ACCÈS. ENCADRER AVEC
MEMBRES HSS 102x102x4.8
ENCADREMENT DE
PASSERELLE, VOIR S201
ENCADREMENT DE
PASSERELLE, VOIR S201
HSS102x102x4.8
OUVERTURE 762 x 2000
610 610 610 610610
ÉG ÉG
610
ÉG
610
ÉG
1068
610 610 610 610610
ÉG ÉG
610
ÉG
610
ÉG
1068
SE
CT
IO
N M
OD
ULA
IR
E 1
2540
SE
CT
IO
N M
OD
ULA
IR
E 2
2184
SE
CT
IO
N M
OD
ULA
IR
E 3
4369
SE
CT
IO
N M
OD
ULA
IR
E 1
2540
SE
CT
IO
N M
OD
ULA
IR
E 2
2184
1
S202F
1
S202F
H
S202F
G
S202F
G
S202F
H
S202F
ÉLU
SOULÈVEMENT -30kN
BAS +68kN
AXIAL
ÉLTS
SOULÈVEMENT -15kN
BAS +51kN
HORIZONTAL
ÉLU +30kN
ÉLTS +21kN
ÉLU
SOULÈVEMENT -10kN
BAS +23kN
AXIAL
ÉLTS
SOULÈVEMENT -5kN
BAS +17kN
HORIZONTAL
ÉLU ±10kN
ÉLTS ±7kN
RÉACTION TYPIQUE AU
POTEAU INTERNE
ÉLU
AXIAL
ÉLTS
HORIZONTAL
ÉLU
AXIAL
ÉLTS
HORIZONTAL
RÉACTION TYPIQUE
AU POTEAU INTERNE
RÉACTION TYPIQUE
AU POTEAU INTERNE
RÉACTION TYPIQUE
AU POTEAU INTERNE
SOULÈVEMENT -30kN
BAS +68kN
SOULÈVEMENT -15kN
BAS +51kN
SOULÈVEMENT -10kN
BAS +23kN
SOULÈVEMENT-5kN
BAS +17kN
ÉLU +30kN
ÉLTS +21kN
ÉLU ±10kN
ÉLTS ±7kN
ÉLU ±30kN
ÉLTS ±21kN
HSS102x102x6.4
HSS102x102x6.4
HSS102x102x4.8 HSS102x102x4.8
SE
CT
IO
N M
OD
ULA
IR
E 3
4369
ENCADREMENT DE
PASSERELLE, VOIR S201
HSS102x102x4.8
HSS102x102x4.8
500 500 500
ÉGÉG
1249
2180
J
S202F
ÉGÉG ÉGÉG
1
S202F
1
S202F
REVÊTEMENT, VOIR
DÉTAIL AU DESSIN S400
1249
2180
1871
500 500 500
ÉGÉG
8153
±4532 CARRÉ
3594 CARRÉ
2753 CARRÉ
1871
CARRÉ
500 500 500
ÉGÉG
500 500 500
ÉGÉG
1100 TYP
1871
18711871
585
585
ÉLU
SOULÈVEMENT -30kN
BAS +68kN
AXIAL
ÉLTS
SOULÈVEMENT -15kN
BAS +51kN
HORIZONTAL
ÉLU
SOULÈVEMENT -10kN
BAS +23kN
AXIAL
ÉLTS
SOULÈVEMENT -5kN
BAS +17kN
HORIZONTAL
ÉLU ±10kN
ÉLTS ±7kN
ÉLU ±30kN
ÉLTS ±21kN
ÉLU
SOULÈVEMENT -30kN
BAS +68kN
AXIAL
ÉLTS
SOULÈVEMENT -15kN
BAS +51kN
HORIZONTAL
ÉLU
SOULÈVEMENT -10kN
BAS +23kN
AXIAL
ÉLTS
SOULÈVEMENT -5kN
BAS +17kN
HORIZONTAL
ÉLU ±10kN
ÉLTS ±7kN
TOIT PAR GCC, TYP.
MASSE MAXIMALE DE
500kg
REVÊTEMENT
CHARGE MORTE
ADDITIONELLE =
0.2kPa
SI HSS152x102x6.4 EST TAILLÉ
APRÈS L'INSTALLATION POUR
PRÉVENIR LES RISQUES DE
TRÉBUCHEMENT, INSTALLER
DES ANCRAGES
SUPPLÉMENTAIRES AUX
EXTRÉMITÉS DE LA COUPURE
430
SCALE 1:50
0.5 1 2
1
millimètresmillimeters
12111098754321056
CAD PRODUCED DRAWING
PRODUIT PAR DAO
4
A
B
D
Vendor Information / Sous-traitant
Pêches et Océans
Canada
Garde côtière
Canadienne
Fisheries and Oceans
Canada
Canadian
Coast Guard
C
23
scale - échelle
date
CCG ref. no. - no. réf. GCC
approved - approuvé
drawing no. - no. dessin sheet-feuille
designed - conception
date
drawn - dessiné
date
Asset - Actif
rev
by
datedescription
A1
Drawing - Dessin
rev-rév
par
checked - vérifié date
poucesinches
654210
REPORT ANY ERRORS OR OMISSIONS TO ILS MANAGER
SIGNALER LES ERREURS OU LES OMISSIONS AU GESTIONNAIRE SLI
File
/ F
ich
ie
r: 1
81
-1
59
56
-0
0_
AL
UM
IN
UM
L
IG
HT
HO
US
E - S
20
0.D
WG - Printed / Imprimé: 2
01
9/0
6/1
3 1
0:2
6
t. 613.829.2800
wsp.com
2611 Queensview Drive
Ottawa, ON Canada
Suite 300
K2B 8K2
f. 613.829.8299
CANADIAN COAST GUARD ALUMINIUM
LIGHTHOUSE MODULAR STRUCTURE
GARDE CÔTIÈRE CANADIENNE PHARE
EN ALUMINIUM, STRUCTURE MODULAIRE
ÉLÉVATIONS DU BÂTIMENT ET
ÉLÉVATIONS D'ENCADREMENT
STRUCTURAL
TDH
WDD
SLH
IJF
181-15956-00 N/A
S200F
S200F
S200F
01/09 0
TSH 2019/03/29
ISSUED FOR 100% DESIGN REVIEW
SOUMIS POUR RÉVISION DE
CONCEPTION 100%
TSH 2019/05/23
ISSUED FOR 100% DESIGN
SOUMIS POUR CONCEPTION 100%
TSH 2019/02/19
ISSUED FOR 60% REVIEW
SOUMIS POUR RÉVISION 60%
2
3
1
ISSUED FOR CONSTRUCTIONFOR CANADIAN COAST GUARD USE IN THE
INTENDED REGIONS ONLY
SOUMIS POUR CONSTRUCTIONPOUR L'UTILISATION DE LA GARDE COTIERE CANADIENNE
DANS LES REGIONS PREVUESSEULEMENT
Samer Jabbour
134865
32x4.8 STANDARD
MESH (19-4) ALUMINUM,
SERRATED GRATING
BOLTED TO PLATFORM
USING TYPE A FIXING
CLIPS
1235
4072
1602
1235
1
S202E
1235
4072
1602 1235
5
5
TYP
INSTALL APPROPRIATE KICKPLATE OR
FILL IN SPACE BETWEEN POSTS TO
PREVENT DANGER TO FOOT TRAFFIC
LIGHT PEDESTAL
TO CCG DETAIL.
SUPPORT BEAM
POSITION TO BE
CONFIRMED PRIOR
FABRICATION
TYPICAL 64x64x6 THICK
PLATE WELDED TO TOP OF
CHANNEL AT INCLINE
BEHIND SHEATHING TO
PREVENT WATER INGRESS.
REFER TO DETAIL B.
HANDRAIL
702
EDGE OF PLATFORM
AT UPPER LEVEL
32x4.8 STANDARD MESH (19-4) ALUMINUM,
SERRATED GRATING BOLTED TO PLATFORM
USING TYPE D FIXING CLIPS
PROVIDE 200 HIGH x 4.8 THICK KICK
PLATE ON 3 SIDES OF LANDING
PLATFORM
ENTRANCE
BELOW
1
S201E
HSS102x102x4.8 CORNER
POST (2-TOTAL) WITH
230x230x12 THICK CAP
PLATES + 3-M16 BOLTS
TO CHANNEL
HSS 102x102x4.8 CORNER
POST TO GROUND
HANDRAIL ON 2
SIDES OF LANDING
PLATFORM. SEE
HANDRAIL DETAIL
450
450
PROVIDE 6 THICK CONNECTION PLATES
(6-TOTAL) OFF THE BACK OF LANDING
CHANNEL. PLATES TO BE BOLTED TO
PERIMETER POSTS. REFER TO DETAILS.
2-60W x 125H x 6 THICK
PLATE. ONE PLATE
CONNECTED TO LADDER
RAIL, ONE PLATE
CONNECTED TO LANDING.
1212
1497
752
298
CLADDING
DETAILS AS
PER S400
100
94
ALUM CHANNEL,
REFER TO PLAN
1067
1
S201E
SCALE 1:20
SECTION
HSS102x102x4.8 MID
LANDING PLATFORM
POSTS
150x150x12 THICK BASE PLATE WITH
4-12.7Ø HILTI HAS ROD + HILTI HY200
EPOXY (OR SIMILAR APPROVED)
WITH 114 EMBEDMENT
35
TYP
35
TYP
POST WITH 5mm
WELD TO PLATE
E
S202E
ALUMINUM PERIMETER
CHANNEL, REFER TO PLAN
200x4.8 ALUM KICK-PLATE
BETWEEN POSTS WELDED
TO PLATFORM PERIMETER
CHANNELS
ALUM HANDRAIL POST:
HSS76x76x6.4 @ 1018 (MAX),
TO BE BOLTED TO SIDE OF
CHANNEL 2x12.7Ø SS BOLTS.
65 VERTICAL CENTRES.
ALUM RAIL: HSS38x38x4.8.
HANDRAIL CONSTRUCTED WITH
ALL WELDED CONSTRUCTION
WITH WELDS GROUND SMOOTH
32 x 4.8 STANDARD MESH
(19-4) ALUMINUM, SERRATED
GRATING BOLTED TO
STRUCTURE USING TYPE A
FIXING CLIPS
5
TYP
CHANNEL,
REFER TO
PLAN
2
S202E
CONNECTION PLATES,
REFER TO PLAN
535
535
CORNER POST
CAP PLATE,
REFER TO PLAN12.7Ø BOLT/SIDE RAIL
HSS51x51x4.8 LADDER
RAIL, TYP
6 THICK BASE PLATE WITH 2-12.7Ø
BOLTS TO TOP OF CHANNEL. TYP
@ LADDER RAILS BEARING ON
PLATFORM (TYP)
25 25100
64
LADDER RAIL
186
1070
SEE S201 FOR FLOOR
FRAMING AT WALKWAY
ELEVATION
186
CHANNEL WELDED
TO BACK OF POSTS
C
S202EF
S202E
6 THICK POST CAP PLATE
65
6 THICK BASE PLATE WITH
2-12.7Ø HILTI HAS ROD
WITH HILTI HY200 EPOXY
(OR SIMILAR APPROVED)
WITH 114 EMBED
25 25100
64
LADDER RUNG PLANK - ALUMINUM
5052H32 3.2 (0.125") THICK (8
GAUGE), 3 ROW 41 (1-5/8") WIDTH,
29 (1-1/8") CHANNEL DEPTH, SLIP
RESISTANT SURFACE, 3% OPEN
AREA.
927 927
1
millimètresmillimeters
12111098754321056
CAD PRODUCED DRAWING
PRODUIT PAR DAO
4
A
B
D
Vendor Information / Sous-traitant
Pêches et Océans
Canada
Garde côtière
Canadienne
Fisheries and Oceans
Canada
Canadian
Coast Guard
C
23
scale - échelle
date
CCG ref. no. - no. réf. GCC
approved - approuvé
drawing no. - no. dessin sheet-feuille
designed - conception
date
drawn - dessiné
date
Asset - Actif
rev
by
datedescription
A1
Drawing - Dessin
rev-rév
par
checked - vérifié date
poucesinches
654210
REPORT ANY ERRORS OR OMISSIONS TO ILS MANAGER
SIGNALER LES ERREURS OU LES OMISSIONS AU GESTIONNAIRE SLI
File
/ F
ich
ie
r: 1
81
-1
59
56
-0
0_
AL
UM
IN
UM
L
IG
HT
HO
US
E - S
20
1 S
20
2.D
WG - Printed / Imprimé: 2
01
9/0
6/1
3 1
0:2
6
t. 613.829.2800
wsp.com
2611 Queensview Drive
Ottawa, ON Canada
Suite 300
K2B 8K2
f. 613.829.8299
CANADIAN COAST GUARD ALUMINIUM
LIGHTHOUSE MODULAR STRUCTURE
GARDE CÔTIÈRE CANADIENNE PHARE
EN ALUMINIUM, STRUCTURE MODULAIRE
PLANS, SECTIONS, & DETAILS
TDH
WDD
SLH
IJF
181-15956-00 N/A
S201E
S201E
S201E
01/09 0
TSH 2019/03/29
ISSUED FOR 100% DESIGN REVIEW
SOUMIS POUR RÉVISION DE
CONCEPTION 100%
TSH 2019/05/23
ISSUED FOR 100% DESIGN
SOUMIS POUR CONCEPTION 100%
TSH 2019/02/19
ISSUED FOR 60% REVIEW
SOUMIS POUR RÉVISION 60%
2
3
1
ISSUED FOR CONSTRUCTIONFOR CANADIAN COAST GUARD USE IN THE
INTENDED REGIONS ONLY
SOUMIS POUR CONSTRUCTIONPOUR L'UTILISATION DE LA GARDE COTIERE CANADIENNE
DANS LES REGIONS PREVUESSEULEMENT
1.51.00
SCALE 1:25
0.5 2.0
Samer Jabbour
134865
GRILLAGE STANDARD (19-4)
32x4.8 EN ALUMINIUM,
CAILLEBOTIS AVEC SURFACE
DENTELÉE BOULONNÉ À LA
PLATE-FORME AVEC
ATTACHES TYPE A
1235
4072
1602
1235
1
S201F
1235
4072
1602 1235
5
5
TYP
INSTALLER PLINTHE APPROPRIÉE OU REMPLIR
ESPACE ENTRE POTEAUX POUR PRÉVENIR
DANGER DE CIRCULATION PIÉTIONNE
PIÉDESTAL POUR
LUMIÈRE, DÉTAIL
PAR GCC. POSITION
DE LA POUTRE DE
SUPPORT DOIT ÊTRE
CONFIRMÉE AVANT
LA FABRICATION
PLAQUE TYPIQUE 64x64x6
SOUDÉE AU HAUT DU
PROFILÉ EN « U » À
L'INCLINAISON DERRIÈRE LE
REVÊTEMENT POUR
PRÉVENIR L'ENTRÉE D'EAU.
VOIR DÉTAIL B.
MAIN
COURANTE
702
BORD DE PLATE-FORME
AU NIVEAU SUPÉRIEUR
GRILLAGE STANDARD (19-4) 32x4.8 EN
ALUMINIUM, CAILLEBOTIS AVEC SURFACE
DENTELÉE BOULONNÉ À LA PLATE-FORME
AVEC ATTACHES TYPE A
FOURNIR PLINTHE 200 HAUT x 4.8
ÉPAIS AUX 3 BORDS DE LA
PLATE-FORME DE PALIER
ENTRÉE DESSOUS
1
S201F
POTEAUX DE COIN
(2-TOTAL) HSS 102x102x4.8
AVEC PLAQUE DE
COURONNEMENT
230x230x12 FIXÉ AU
PROFILÉ EN « U » AVEC
BOULONS 3-M16
POTEAU HSS 102x102x4.8
JUSQU'AU SOL
MAIN COURANTE
AUX 2 CÔTÉS DE LA
PLATE-FORME DE
PALIER. VOIR DÉTAIL
DE MAIN COURANTE
450
450
FOURNIR PLAQUES DE CONNEXION (6-TOTAL)
ÉPAISSEUR 6 AU DOS DU PROFILÉ EN « U ».
PLAQUES DOIT ÊTRE BOULONNÉES AUX
POTEAUX DE PÉRIMÈTRE. VOIR DÉTAILS.
2 PLAQUES 60L x 125H x 6
ÉPAIS. UNE PLAQUE
RELIÉE AU RAIL DE
L'ÉCHELLE, UNE PLAQUE
RELIÉE AU PALIER.
1212
1497
752
298
REVÊTEMENT VOIR
DÉTAILS AU S400
100
94
PROFILÉ EN « U » EN
ALUMINIUM, VOIR PLAN
1067
POTEAUX HSS102x102x4.8
POUR PLATE-FORME DE
PALIER MI-HAUTEUR
PLAQUE DE BASE 150x150x12 AVEC
TIGES FILETÉES HILTI HAS 4-12.7Φ,
FOURNIR ÉPOXY HILTI HY200 (OU
SEMBLABLE APPROUVÉ) AVEC
ENCASTREMENT 114
35
TYP
35
TYP
POTEAU FIXÉ À LA
PLAQUE AVEC
SOUDURE 5mm
E
S202F
PROFILÉS EN « U » DE PÉRIMÈTRE
DE LA PLATE-FORME, VOIR PLAN
PLINTHE 200x4.8 EN ALUMINIUM
ENTRE POTEAUX, SOUDÉ AUX
PROFILÉS EN « U » AU PÉRIMÈTRE
DE LA PLATE-FORME
POTEAU DE MAIN COURANTE EN
ALUM: HSS 76x76x6.4 @ 1018 (MAX),
BOULONNÉ AU CÔTÉ DU PROFILÉ EN
« U » 2x12.7Φ BOULONS EN ACIER
INOX. DISTANCE VERTICALE 65 c/c
RAIL ALUM: HSS 38x38x4.8.
MAIN COURANTE PRODUITE AVEC
TOUTE CONSTRUCTION SOUDÉE.
MEULER POUR RENDRE LA
SURFACE DE SOUDURE LISSE.
GRILLAGE STANDARD (19-4) 32x4.8
EN ALUMINIUM, CAILLEBOTIS AVEC
SURFACE DENTELÉE BOULONNÉ À
LA PLATE-FORME AVEC ATTACHES
TYPE A
5
TYP
PROFILÉS EN
« U » EN
ALUMINIUM,
VOIR PLAN
2
S202F
PLAQUES DE
CONNEXION, VOIR
PLAN
535
535
PLAQUE DE
COURONNEMENT POUR
POTEAU DE COIN, VOIR
PLAN
BOULONS 2-12.7Ø PAR
CÔTÉ DE RAIL
RAIL D'ÉCHELLE
HSS51x51x4.8, TYP
PLAQUE DE BASE ÉPAISSEUR 6
AVEC BOULONS 2-12.7Φ FIXÉS AU
HAUT DU PROFILÉ EN « U ». TYP
AUX RAILS D'ÉCHELLE APPUYÉS
SUR LA PLATE-FORME (TYP)
25 25100
64
RAIL D'ÉCHELLE
186
1070
VOIR S201 POUR
ENCADREMENT AU
NIVEAU DE LA
PASSERELLE
186
PROFILÉ EN « U » SOUDÉ
AU DOS DES POTEAUX
C
S202FF
S202F
PLAQUE DE COURONNEMENT
ÉPAISSEUR 6
65
PLAQUE DE BASE ÉPAISSEUR 6
AVEC TIGES FILETÉES HILTI HAS
2-12.7Φ, FOURNIR ÉPOXY HILTI
HY200 (OU SEMBLABLE APPROUVÉ)
AVEC ENCASTREMENT 114
25 25100
64
BARREAUX D'ÉCHELLE - ALUMINIUM
5052H32 3.2 (0.125") ÉPAIS (CALIBRE
8), 3 RANGÉES LARGEUR 41 (1-5/8"),
PROFILÉ EN « U » PROFONDEUR 29
(1-1/8"), SURFACE ANTIDÉRAPANTE,
SURFACE 3% OUVERTE
927 927
1
S201F
ÉCHELLE 1:20
COUPE
1
millimètresmillimeters
12111098754321056
CAD PRODUCED DRAWING
PRODUIT PAR DAO
4
A
B
D
Vendor Information / Sous-traitant
Pêches et Océans
Canada
Garde côtière
Canadienne
Fisheries and Oceans
Canada
Canadian
Coast Guard
C
23
scale - échelle
date
CCG ref. no. - no. réf. GCC
approved - approuvé
drawing no. - no. dessin sheet-feuille
designed - conception
date
drawn - dessiné
date
Asset - Actif
rev
by
datedescription
A1
Drawing - Dessin
rev-rév
par
checked - vérifié date
poucesinches
654210
REPORT ANY ERRORS OR OMISSIONS TO ILS MANAGER
SIGNALER LES ERREURS OU LES OMISSIONS AU GESTIONNAIRE SLI
File
/ F
ich
ie
r: 1
81
-1
59
56
-0
0_
AL
UM
IN
UM
L
IG
HT
HO
US
E - S
20
1 S
20
2.D
WG - Printed / Imprimé: 2
01
9/0
6/1
3 1
0:2
6
t. 613.829.2800
wsp.com
2611 Queensview Drive
Ottawa, ON Canada
Suite 300
K2B 8K2
f. 613.829.8299
CANADIAN COAST GUARD ALUMINIUM
LIGHTHOUSE MODULAR STRUCTURE
GARDE CÔTIÈRE CANADIENNE PHARE
EN ALUMINIUM, STRUCTURE MODULAIRE
PLANS, SECTIONS ET DÉTAILS
TDH
WDD
SLH
IJF
181-15956-00 N/A
S201F
S201F
S201F
01/09 0
TSH 2019/03/29
ISSUED FOR 100% DESIGN REVIEW
SOUMIS POUR RÉVISION DE
CONCEPTION 100%
TSH 2019/05/23
ISSUED FOR 100% DESIGN
SOUMIS POUR CONCEPTION 100%
TSH 2019/02/19
ISSUED FOR 60% REVIEW
SOUMIS POUR RÉVISION 60%
2
3
1
ISSUED FOR CONSTRUCTIONFOR CANADIAN COAST GUARD USE IN THE
INTENDED REGIONS ONLY
SOUMIS POUR CONSTRUCTIONPOUR L'UTILISATION DE LA GARDE COTIERE CANADIENNE
DANS LES REGIONS PREVUESSEULEMENT
1.51.00
SCALE 1:20
0.5
Samer Jabbour
134865
±4532
SQUARE
MO
DU
LA
R S
EC
TIO
N 1
2540
MO
DU
LA
R S
EC
TIO
N 2
2184
MO
DU
LA
R S
EC
TIO
N 3
4369
C
S202E
A
S202E
TYPICAL LIFT LUG
AT CORNER POSTS
D
S202E
WALKWAY
FRAMING
F
S202E
1
S202E
SCALE 1:50
GENERAL ASSEMBLY CROSS SECTION
B
S202E
C
S202E
E
S202E
1249
2180
ROOF BY CCG
3594
SQUARE
2753
SQUARE
1871
SQUARE
74.42°
R38
25.4Ø HOLE
9.5 THICK PLATE±90
105
76
ALUM CORNER POST:
HSS102x102x6.4 (TYP)
5
F
S202E
SCALE 1:10
TYPICAL LIFTING LUG
HSS152x102x4.8
12.7Ø THROUGH BOLTS
@ 610 SPACING (MAX)
HSS102x102
POST, REFER TO
ELEVATIONS
ALUM BEAM, REFER
TO ELEVATIONS
5
WINDOW SUPPLIED BY
COAST GUARD
±1870 SQUARE
B
S202E
SCALE 1:10
WALKWAY PLATFORM TO
PERIMETER COLUMN
ALUM POSTS
CHANNEL BOTTOM TO BE 50
FROM ALUM POSTS. REFER
TO PLAN
TYPICAL PLATE TO STOP
WATER INGRESS. REFER
TO PLAN
C
S202E
SCALE 1:10
ASSEMBLY 1 TO 2
CONNECTION
A
S202E
SCALE 1:10
ASSEMBLY 3 WINDOW
SUPPORT
5
TYP
CJP
1220 x 762 C
LE
AR
O
PE
NIN
G
CO
NF
IR
M W
IT
H W
IN
DO
W S
UP
PLIE
R
ALUM HSS102x102x4.8
WINDOW FRAMING, REFER
TO ELEVATIONS
ALUM HSS102x102x4.8 AT
EACH SIDE OF WINDOW
OPENING
5
TYP
G
S202E
SCALE 1:10
TYPICAL WINDOW FRAMING
D
S202E
SCALE 1:5
BASE FOUNDATION DETAIL
HSS152x102x6.4 (LSH) ALL AROUND
PERIMETER AND WELD ALL CORNERS
(USE 140 WIDE STRIP OF "FoamSealR"
SILL GASKET BY OWENS CORNING
BENEATH HSS
12.7Ø HILTI HAS ROD + HILTI HIT-HY200
EPOXY ADHESIVE WITH 114.3
EMBEDMENT. LOCATE ANCHORS @
610 (MAX) AROUND PERIMETER
CONCRETE
SLAB-ON-GRADE
BY FOUNDATION
ENGINEER
CONCRETE
FOUNDATION WALL
BY FOUNDATION
ENGINEER
CLADDING DETAIL,
REFER TO
DRAWINGS S400
5
ALUMINUM TUBE STUDS
(SEE STRUCTURAL
FRAMING ELEVATIONS
FOR LOCATIONS &
SIZES)
100 MIN.
89x89x6.4 ANGLE WELDED TO
HSS. (5mm FILLET WELD)
LADDER LANDING
FRAMING MEMBER,
REFER TO PLAN
152x64x6.4 ALUM
CONNECTION
PLATE. SEE PLAN.
5
5
5
E
S202E
SCALE 1:5
LANDING PLATFORM TO
POST DETAIL
2-16M STAINLESS
STEEL BOLT
THROUGH POST
25
25
5
TYP
CJP
2000 x 762 C
LE
AR
O
PE
NIN
G
CO
NF
IR
M W
IT
H D
OO
R S
UP
PLIE
R
5
ALUM TUBE, REFER TO
ELEVATIONS
ALUM HSS102x102x4.8
DOOR FRAMING, REFER TO
ELEVATIONS
ALUM HSS102x102x4.8 AT
EACH SIDE OF DOOR
HSS152x102x6.4 (LSH) ALL
AROUND PERIMETER OF
FOUNDATION
7
8
.
8
5
°
5
5
TYP
H
S202E
SCALE 1:10
TYPICAL DOOR FRAMING
200 M
IN
BY FOUNDATION
ENGINEER
SLAB ON GRADE BY
FOUNDATION ENGINEER
SUB-GRADE TO BE
APPROVED BY
GEOTECH ENGINEER
126
2
S202E
SCALE 1:20
SECTION
PROVIDE 200x12x75 BASE
PLATE WITH 2-16Ø HILTI
KB TZ, 79 EMBED TYP
35
TYP
HSS51x51x4.8 SIDE
RAILS TYP.
CONNECTION PLATES,
REFER TO PLAN
PLATFORM POST
BEYOND
PLATFORM POST
BEYOND
LADDER PLATFORM
LADDER RUNGS,
REFER TO 1/S201
450
TYP
300 M
AX
TY
P
SLAB BY FOUNDATION
ENGINEER
200
MIN
1070
610
1070
610
2000 x 762 C
LE
AR
O
PE
NIN
G
CO
NF
IR
M W
IT
H D
OO
R S
UP
PLIE
R
J
S202E
SCALE 1:10
DOOR FRAMING @
ASSEMBLY 3 SECTION
HSS FRAMING,
REFER TO PLAN
ALUM HSS102x102x4.8 AT
EACH SIDE OF DOOR
CJP
ALUM HSS102x102x4.8
DOOR FRAMING, REFER TO
ELEVATIONS
5
TYP
5
TYP
1
millimètresmillimeters
12111098754321056
CAD PRODUCED DRAWING
PRODUIT PAR DAO
4
A
B
D
Vendor Information / Sous-traitant
Pêches et Océans
Canada
Garde côtière
Canadienne
Fisheries and Oceans
Canada
Canadian
Coast Guard
C
23
scale - échelle
date
CCG ref. no. - no. réf. GCC
approved - approuvé
drawing no. - no. dessin sheet-feuille
designed - conception
date
drawn - dessiné
date
Asset - Actif
rev
by
datedescription
A1
Drawing - Dessin
rev-rév
par
checked - vérifié date
poucesinches
654210
REPORT ANY ERRORS OR OMISSIONS TO ILS MANAGER
SIGNALER LES ERREURS OU LES OMISSIONS AU GESTIONNAIRE SLI
File
/ F
ich
ie
r: 1
81
-1
59
56
-0
0_
AL
UM
IN
UM
L
IG
HT
HO
US
E - S
20
1 S
20
2.D
WG - Printed / Imprimé: 2
01
9/0
6/1
3 1
0:2
7
t. 613.829.2800
wsp.com
2611 Queensview Drive
Ottawa, ON Canada
Suite 300
K2B 8K2
f. 613.829.8299
CANADIAN COAST GUARD ALUMINIUM
LIGHTHOUSE MODULAR STRUCTURE
GARDE CÔTIÈRE CANADIENNE PHARE
EN ALUMINIUM, STRUCTURE MODULAIRE
ELEVATIONS, SECTIONS AND
DETAILS
TDH
WDD
SLH
IJF
181-15956-00 AS NOTED
S202E
S202E
S202E
01/09 0
TSH 2019/03/29
ISSUED FOR 100% DESIGN REVIEW
SOUMIS POUR RÉVISION DE
CONCEPTION 100%
TSH 2019/05/23
ISSUED FOR 100% DESIGN
SOUMIS POUR CONCEPTION 100%
TSH 2019/02/19
ISSUED FOR 60% REVIEW
SOUMIS POUR RÉVISION 60%
2
3
1
ISSUED FOR CONSTRUCTIONFOR CANADIAN COAST GUARD USE IN THE
INTENDED REGIONS ONLY
SOUMIS POUR CONSTRUCTIONPOUR L'UTILISATION DE LA GARDE COTIERE CANADIENNE
DANS LES REGIONS PREVUESSEULEMENT
Samer Jabbour
134865
±4532
CARRÉ
SE
CT
IO
N M
OD
ULA
IR
E 1
2540
SE
CT
IO
N M
OD
ULA
IR
E 2
2184
SE
CT
IO
N M
OD
ULA
IR
E 3
4369
C
S202F
A
S202F
BAGUE DE LEVAGE
TYPIQUE AUX POTEAUX
DE COIN
D
S202F
ENCADREMENT DE
PASSERELLE
F
S202F
1
S202F
ÉCHELLE 1:50
COUPE TRANSVERSALE GÉNÉRALE DE L'ASSEMBLAGE
B
S202F
C
S202F
E
S202F
1249
2180
TOIT PAR GCC
3594
CARRÉ
2753
CARRÉ
1871
CARRÉ
74.42°
R38
TROU 25.4Ø
PLAQUE ÉPAISSEUR 9.5
±90
105
76
POTEAU DE COIN EN
ALUMINIUM:
HSS102x102x6.4 (TYP)
5
F
S202F
ÉCHELLE 1:10
BAGUE DE LEVAGE TYPIQUE
D
S202F
ÉCHELLE 1:5
DÉTAIL BASE DES MURS À LA FONDATION
HSS152x102x6.4 (CLH) AUTOUR DU
PÉRIMÈTRE ET SOUDÉ À TOUT LES
COINS (UTILISER BANDE DE JOINT «
FoamSealR » DE LARGEUR 140mm PAR
OWENS CORNING SOUS MEMBRE HSS
12.7Ø
TIGE FILETÉ HILTI HAS AVEC
ADHÉSIF ÉPOXY HILTI HIT-HY200,
ENCASTREMENT 114.3. FOURNIR
ANCRAGE @ 610 (MAX) AUTOUR DU
PÉRIMÈTRE
DALLE SUR SOL EN
BÉTON PAR
INGÉNIEUR DE
FONDATION
MUR FONDATION EN
BÉTON PAR INGÉNIEUR
DE FONDATION
DÉTAIL DE REVÊTEMENT,
VOIR S400
5
PROFILÉ CREUX EN
ALUMINIUM (VOIR
ÉLÉVATIONS
D'ENCADREMENT POUR
ENDROITS ET DIMENSIONS)
100 MIN.
CORNIÈRE 89x89x6.4 SOUDÉE
AU MEMBRE HSS. (SOUDURE
À BOURRELET 5mm)
BOULONNÉ AU CÔTÉ DU PROFILÉ EN
FOURNIR PLAQUE DE
BASE 200x75x12 AVEC
ANCRAGE 2-16Ø HILTI KB
TZ, ENCASTREMENT 79
TYP
35
TYP
RAILS D'ÉCHELLE HSS
51x51x4.8 TYP.
PLAQUES DE
CONNEXION, VOIR PLAN
POTEAU DE
PLATE-FORME AU-DELÀ
POTEAU DE
PLATE-FORME
AU-DELÀ
PALIER D'ÉCHELLE
BARREAUX D'ÉCHELLE,
VOIR 1/S201F
450
TYP
300 M
AX
TY
P
1070
DALLE PAR INGÉNIEUR DE
FONDATION
200
MIN
2
S202F
ÉCHELLE 1:20
COUPE
610
1070
610
HSS152x102x4.8
12.7Ø BOULONS
TRAVERSANTS @
610 c/c (MAX)
HSS102x102
POTEAU, VOIR
ÉLÉVATIONS
POUTRE EN
ALUMINIUM, VOIR
ÉLÉVATIONS
5
FENÊTRE FOURNIE
PAR GARDE CÔTIÈRE
CANADIENNE
±1870 CARRÉ
B
S202F
ÉCHELLE 1:10
PLATE-FORME DE PASSERELLE À
LA COLONNE DE PÉRIMÈTRE
POTEAUX EN ALUMINIUM
BAS DU PROFILÉ EN « U »
DOIT ÊTRE 50 DES POTEAUX
EN ALUMINIUM. VOIR PLAN
PLAQUE TYPIQUE POUR
PRÉVENIR PÉNÉTRATION
DE L'EAU, VOIR PLAN
C
S202F
ÉCHELLE 1:10
CONNEXION DU MODULE 1
AU MODULE 2
A
S202F
ÉCHELLE 1:10
SUPPORT DE FÊNETRE AU
MODULE 3
MEMBRE D'ENCADREMENT
DU PALIER D'ÉCHELLE,
VOIR PLAN
PLAQUE DE CONNEXION
EN ALUMINIUM
152x64x6.4, VOIR PLAN
5
5
5
2-16M BOULONS
TRAVERSANTS EN
ACIER INOX AU
TRAVERS DU
POTEAU
25
25
E
S202F
ÉCHELLE 1:5
DÉTAIL DE LA PLATE-FORME DE PALIER AU POTEAU
5
TYP
CJP
OU
VE
RT
UR
E 2000 x 762
CO
NF
IR
ME
R A
VE
C F
OU
RN
IS
SE
UR
D
E P
OR
TE
5
PROFILÉ CREUX EN
ALUMINIUM, VOIR
ÉLÉVATIONS
ENCADREMENT DE PORTE
HSS102x102x4.8 EN
ALUMINIUM, VOIR
ÉLÉVATIONS
HSS102x102x4.8 À CHAQUE
CÔTÉ DE L'OUVERTURE
DE PORTE
HSS152x102x6.4 (CLH)
AUTOUR DU PÉRIMÈTRE
DE LA FONDATION
7
8
.
8
5
°
5
5
TYP
H
S202F
ÉCHELLE 1:10
ENCADREMENT TYPIQUE POUR PORTE
200 M
IN
PAR INGÉNIEUR DE
FONDATION
DALLE SUR SOL PAR
INGÉNIEUR DE FONDATION
SOL DE FONDATION DOIT
ÊTRE APPROUVÉ PAR
INGÉNIEUR GÉOTECHNIQUE
126
OU
VE
RT
UR
E 2000 x 762
CO
NF
IR
ME
R A
VE
C F
OU
RN
IS
SE
UR
D
E P
OR
TE
J
S202F
ÉCHELLE 1:10
COUPE ENCADREMENT
DE PORTE AU MODULE 3
ENCADREMENT HSS,
VOIR PLAN
HSS102x102x4.8 EN
ALUMINIUM À CHAQUE
CÔTÉ DE LA PORTE
CJP
ENCADREMENT DE PORTE
HSS102x102x4.8 EN
ALUMINIUM, VOIR ÉLÉVATIONS
5
TYP
5
JOINT À
PÉNÉTRATION
COMPLÈTE
5
TYP
CJP
OU
VE
RT
UR
E 1220 x 762
CONFIRMER AVEC FOURNISSEUR DE FENÊTRE
ENCADREMENT DE
FENÊTRE HSS102x102x4.8
EN ALUMINIUM, VOIR
ÉLÉVATIONS
HSS102x102x4.8 À CHAQUE
CÔTÉ DE L'OUVERTURE
DE FENÊTRE
5
TYP
G
S202F
ÉCHELLE 1:10
ENCADREMENT TYPIQUE DE FENÊTRE
1
millimètresmillimeters
12111098754321056
CAD PRODUCED DRAWING
PRODUIT PAR DAO
4
A
B
D
Vendor Information / Sous-traitant
Pêches et Océans
Canada
Garde côtière
Canadienne
Fisheries and Oceans
Canada
Canadian
Coast Guard
C
23
scale - échelle
date
CCG ref. no. - no. réf. GCC
approved - approuvé
drawing no. - no. dessin sheet-feuille
designed - conception
date
drawn - dessiné
date
Asset - Actif
rev
by
datedescription
A1
Drawing - Dessin
rev-rév
par
checked - vérifié date
poucesinches
654210
REPORT ANY ERRORS OR OMISSIONS TO ILS MANAGER
SIGNALER LES ERREURS OU LES OMISSIONS AU GESTIONNAIRE SLI
File
/ F
ich
ie
r: 1
81
-1
59
56
-0
0_
AL
UM
IN
UM
L
IG
HT
HO
US
E - S
20
1 S
20
2.D
WG - Printed / Imprimé: 2
01
9/0
6/1
3 1
0:2
7
t. 613.829.2800
wsp.com
2611 Queensview Drive
Ottawa, ON Canada
Suite 300
K2B 8K2
f. 613.829.8299
CANADIAN COAST GUARD ALUMINIUM
LIGHTHOUSE MODULAR STRUCTURE
GARDE CÔTIÈRE CANADIENNE PHARE
EN ALUMINIUM, STRUCTURE MODULAIRE
ÉLÉVATIONS, SECTIONS ET
DÉTAILS
TDH
WDD
SLH
IJF
181-15956-00 N/A
S202F
S202F
S202F
01/09 0
TSH 2019/03/29
ISSUED FOR 100% DESIGN REVIEW
SOUMIS POUR RÉVISION DE
CONCEPTION 100%
TSH 2019/05/23
ISSUED FOR 100% DESIGN
SOUMIS POUR CONCEPTION 100%
TSH 2019/02/19
ISSUED FOR 60% REVIEW
SOUMIS POUR RÉVISION 60%
ISSUED FOR CONSTRUCTIONFOR CANADIAN COAST GUARD USE IN THE
INTENDED REGIONS ONLY
SOUMIS POUR CONSTRUCTIONPOUR L'UTILISATION DE LA GARDE COTIERE CANADIENNE
DANS LES REGIONS PREVUESSEULEMENT
2
3
1
Samer Jabbour
134865
TUCK ALL LAP JOINTS
CONCRETE FOUNDATION WALL
203, (M
IN
)
FIN GRADE
FULLY ADHERED MEMBRANE FLASHING
CONT AIR BARRIER MEMBRANE (SEAL/TAPE
ALL JOINTS)
STARTER STRIP
CAPE COD NAILITE EASY-UP LOCKING
SYSTEM EXTERIOR CLADDING
COMPRESSIBLE SILL GASKET
SEALANT WITH BACKER ROD
TUCK TAPE NAILING FLANGE OF J-TRIM TO
PREVENT WATER INFILTRATION
FULLY ADHERED MEMBRANE FLASHING
WRAPPED OVER ALUM. STRUCTURE AND
EXTENDING 304.8mm (MIN) DOWN WALL
CONT AIR BARRIER MEMBRANE (SEAL/TAPE
ALL JOINTS)
CAPE COD NAILITE EASY-UP LOCKING
SYSTEM EXTERIOR CLADDING
19 THICK EXTERIOR GRADE PLYWOOD
FULLY ADHERED MEMBRANE FLASHING
WRAPPED OVER ALUM. STRUCTURE AND
EXTENDING 304.8mm (MIN) DOWN WALL
CONT AIR BARRIER MEMBRANE (SEAL/TAPE
ALL JOINTS)
CAPE COD NAILITE SIDINGCORNER POST, REFER TO
FRAME ELEVATIONS
PREMANUFACTURED EXTERIOR CORNER
POST. TUCK TAPE NAILING FLANGES TO
ENSURE NO WATER INFILTRATION
ALUMINUM EXTERIOR DOOR
SOLID VINYL TRIM
2032 C
LE
AR
O
PE
NIN
G
762 C
LE
AR
O
PE
NIN
G
ALUMINUM EXTERIOR
DOOR
SEALANT
SOLID VINYL TRIM
VARIES
INSIDE CORNER POST
TUCK TAPE NAILING FLANGES
OF CORNER POST TO ENSURE
NO WATER INFILTRATION
CAPE COD NAILITE EASY-UP
LOCKING SYSTEM EXTERIOR
CLADDING
762 C
LE
AR
O
PE
NIN
G
VARIES
6.4 THICK ALUMINUM ATTACHMENT
PLATE WELDED TO FRAMING
SEALANT
@ J-TRIM
51
87
2000
CLE
AR
OP
EN
IN
G
PROVIDE CONTINUOUS DRIP
EDGE
SOLID VINYL TRIM
STARTER STRIP
RUN 6.4 THICK ALUM ROOF
SHEET 152.4mm (MIN) UP WALL
CAPE COD NAILITE EASY-UP
LOCKING SYSTEM EXTERIOR
CLADDING
FULLY ADHERED MEMBRANE
FLASHING OVERLAPPING
PRE-FIN 22ga ALUMINUM
ROOF SHEET
CONT AIR BARRIER MEMBRANE
(SEAL/TAPE ALL JOINTS)
CONT AIR BARRIER MEMBRANE
(SEAL/TAPE ALL JOINTS).
ENSURE CONTINUITY ALL
AROUND
19 THICK EXTERIOR GRADE
PLYWOOD SHEATHING
ALUMINUM DOOR FRAME WELDED TO
STRUCT MEMBERS (HEAD & JAMB)
ALUMINUM EXTERIOR DOOR
ALUMINUM WELDED TO DOOR FRAME
ALUMINUM HSS102x102x4.8
DOOR FRAMING
STARTER STRIP
RUN 6.4 THICK ALUM ROOF
SHEET 152.4mm (MIN) UP WALL
CAPE COD NAILITE EASY-UP
LOCKING SYSTEM EXTERIOR
CLADDING
FULLY ADHERED MEMBRANE
FLASHING OVERLAPPING
PRE-FIN 6.4 THICK
ALUMINUM ROOF SHEET
CONT AIR BARRIER MEMBRANE
(SEAL/TAPE ALL JOINTS)
CONT AIR BARRIER MEMBRANE
(SEAL/TAPE ALL JOINTS).
ENSURE CONTINUITY ALL
AROUND
19 THICK EXTERIOR GRADE
PLYWOOD SHEATHING
1220 x 762 CLEAR OPENING
VINYL WINDOW
UNIT
PRE-FIN ALUM FLASHING (24ga) SET IN
CONT BEAD OF SEALANT/ADHESIVE
SEALANT & BACKER ROD ALL AROUND.
EXCEPT ON TOP OF METAL FLASHING
IN ORDER TO PERMIT DRAINAGE
FULLY ADHERED MEMBRANE FLASHING
(2 STRIPS) AROUND WINDOW (INNER
LAYER OVERLAPPING WINDOW
FLANGES & OUTER LAYER
OVERLAPPING PRE-FIN ALUM
FLASHING)
VINYL WINDOW UNIT
SEALANT & BACKER ROD ALL
AROUND
TUCK TAPE NAILING FLANGE
OF J-TRIM TO PREVENT
WATER INFILTRATION
SOLID VINYL TRIM
SEALANT AT J-TRIM
1220 C
LE
AR
O
PE
NIN
GW
IN
DO
W O
PE
NIN
G LO
CA
TE
D A
T
MID
HE
IG
HT
O
F M
OD
ULA
R S
EC
TIO
N 2
ALUMINUM
HSS102x102x4.8
DOOR FRAMING
ALUMINUM HSS102x102x4.8
DOOR FRAMING
ALUMINUM HSS102x102x4.8
WINDOW FRAMING
LANTERN UNIT SUPPLIED BY CANADIAN
COAST GUARD
ALUMINUM HSS102x102x4.8
WINDOW FRAMING
CONT AIR BARRIER MEMBRANE
(SEAL/TAPE ALL JOINTS) ENSURE
CONTINUITY ALL AROUND
INSIDE CORNER POST
TUCK TAPE NAILING FLANGES
OF CORNER POST TO ENSURE
NO WATER INFILTRATION
CAPE COD NAILITE EASY-UP
LOCKING SYSTEM EXTERIOR
CLADDING
SOLID VINYL TRIM
SEALANT
@ J-TRIM
VINYL WINDOW UNIT
SEALANT & BACKER ROD
ALL AROUND
6.4 THICK ALUMINUM ATTACHMENT
PLATE WELDED TO FRAMING
ALUMINUM HSS102x102x4.8 DOOR
FRAMING
CONT AIR BARRIER MEMBRANE
(SEAL/TAPE ALL JOINTS) ENSURE
CONTINUITY ALL AROUND
BASE
19 THICK EXTERIOR GRADE
PLYWOOD SHEATHING
PROVIDE BACKER ROD & SEAL BETWEEN
CLADDING & DOOR
WRAP MEMBRANE ONTO STRUCTURE, (TYP)
CONTINUOUS 24ga PREFINISHED METAL
FLASHING. COVER OVER MEMBRANE
1
millimètresmillimeters
12111098754321056
CAD PRODUCED DRAWING
PRODUIT PAR DAO
4
A
B
D
Vendor Information / Sous-traitant
Pêches et Océans
Canada
Garde côtière
Canadienne
Fisheries and Oceans
Canada
Canadian
Coast Guard
C
23
scale - échelle
date
CCG ref. no. - no. réf. GCC
approved - approuvé
drawing no. - no. dessin sheet-feuille
designed - conception
date
drawn - dessiné
date
Asset - Actif
rev
by
datedescription
A1
Drawing - Dessin
rev-rév
par
checked - vérifié date
poucesinches
654210
REPORT ANY ERRORS OR OMISSIONS TO ILS MANAGER
SIGNALER LES ERREURS OU LES OMISSIONS AU GESTIONNAIRE SLI
File
/ F
ich
ie
r: 1
81
-1
59
56
-0
0_
AL
UM
IN
UM
L
IG
HT
HO
US
E - S
40
0.D
WG - Printed / Imprimé: 2
01
9/0
6/1
3 1
0:2
7
t. 613.829.2800
wsp.com
2611 Queensview Drive
Ottawa, ON Canada
Suite 300
K2B 8K2
f. 613.829.8299
CANADIAN COAST GUARD ALUMINIUM
LIGHTHOUSE MODULAR STRUCTURE
GARDE CÔTIÈRE CANADIENNE PHARE
EN ALUMINIUM, STRUCTURE MODULAIRE
BUILDING DETAILS
TDH
WDD
SLH
IJF
181-15956-00 AS NOTED
S400E
S400E
S400E
01/09 0
TSH 2019/03/29
ISSUED FOR 100% DESIGN REVIEW
SOUMIS POUR RÉVISION DE
CONCEPTION 100%
TSH 2019/05/23
ISSUED FOR 100% DESIGN
SOUMIS POUR CONCEPTION 100%
TSH 2019/02/19
ISSUED FOR 60% REVIEW
SOUMIS POUR RÉVISION 60%
2
3
1
ISSUED FOR CONSTRUCTIONFOR CANADIAN COAST GUARD USE IN THE
INTENDED REGIONS ONLY
SOUMIS POUR CONSTRUCTIONPOUR L'UTILISATION DE LA GARDE COTIERE CANADIENNE
DANS LES REGIONS PREVUESSEULEMENT
Samer Jabbour
134865
DÉTAIL TYPIQUE D'ENCADREMENT DE PORTE AU SEUIL
ÉCHELLE 1:5
DÉTAIL TYPIQUE D'ENCADREMENT DE FENÊTRE AU SEUIL
ÉCHELLE 1:5
DÉTAIL TYPIQUE AU COIN DU BÂTIMENT
ÉCHELLE 1:5
REPLIER TOUS JOINTS DE
REVAUCHEMENT
MUR DE FONDATION EN BÉTON
203, (M
IN
)
SOL FINI
MEMBRANE DE SOLIN COMPLÈTEMENT
ADHÉRÉE
MEMBRANE PARE-AIR CONT
(SCELLER TOUS LES JOINTS AVEC
RUBAN ADHÉSIF)
BANDE DE DÉMARRAGE
REVÊTEMENT EXTÉRIEUR DE
SYSTÈME D'ENCLENCHEMENT CAPE
COD NAILITE EASY-UP
OINT DE SEUIL COMPRESSIBLE
CORDON DE REMPLISSAGE ET SCELLANT
CHEVAUCHER BRIDES DU RUBAN DE
RACCORDEMENT DE LA BORDURE EN J
POUR PRÉVENIR L'INFILTRATION D'EAU
MEMBRANE SOLIN COMPLÈTEMENT
ADHÉRÉE, RECOUVRANT LA STRUCTURE
EN ALUMINIUM AVEC PROJECTION DE
304.8mm (MIN) EN DESCENDANT LE MUR.
MEMBRANE PARE-AIR CONT (SCELLER
TOUS LES JOINTS AVEC RUBAN ADHÉSIF)
REVÊTEMENT EXTÉRIEUR DE SYSTÈME
D'ENCLENCHEMENT CAPE COD NAILITE
EASY-UP
REVÊTEMENT CONTRE-PLAQUÉ ÉPAISSEUR
19, CLASSÉ POUR APPLICATION EXTÉRIEUR
MEMBRANE SOLIN COMPLÈTEMENT
ADHÉRÉE, RECOUVRANT LA STRUCTURE
EN ALUMINIUM AVEC PROJECTION DE
304.8mm (MIN) EN DESCENDANT LE MUR.
MEMBRANE PARE-AIR CONT (SCELLER
TOUS LES JOINTS AVEC RUBAN ADHÉSIF)
REVÊTEMENT EXTÉRIEUR DE SYSTÈME
D'ENCLENCHEMENT CAPE COD NAILITE
EASY-UP
POTEAU DE COIN, VOIR
ÉLÉVATIONS
POTEAU EXTÉRIEUR PRÉMANUFACTURÉ.
CHEVAUCHER LES BRIDES DU RUBAN DE
RACCORDEMENT POUR PRÉVENIR
L'INFILTRATION D'EAU
PORTE EXTÉRIEURE EN
ALUMINIUM
BORDURE EN VINYLE
SOLIDE
OU
VE
RT
UR
E 2032
OU
VE
RT
UR
E 762
PORTE EXTÉRIEURE EN
ALUMINIUM
SCELLANT
BORDURE EN VINYLE
SOLIDE
VARIES
POTEAU DE COIN INTÉRIEUR
CHEVAUCHER LES BRIDES DU
RUBAN DE RACCORDEMENT
AU POTEAU DE COIN POUR
ASSURER PRÉVENIR
L'INFILTRATION D'EAU
REVÊTEMENT EXTÉRIEUR DE
SYSTÈME D'ENCLENCHEMENT
CAPE COD NAILITE EASY-UP
OU
VE
RT
UR
E 762
VARIES
PLAQUE D'ATTACHE EN ALUMINIUM
ÉPAISSEUR 6.4 SOUDÉE À
L'ENCADREMENT
SCELLANT À LA
BORDURE EN J
51
87
2000
OU
VE
RT
UR
E
FOURNIR LARMIER CONTINUE
BORDURE EN VINYLE
SOLIDE
BANDE DE DÉMARRAGE
POSER FEUILLE D'ALUMINIUM D'ÉPAISSEUR
6.4 UNE DISTANCE VERTICALE DE 152.4mm
(MIN) SUR LE MUR
REVÊTEMENT EXTÉRIEUR DE SYSTÈME
D'ENCLENCHEMENT CAPE COD NAILITE
EASY-UP
MEMBRANE COMPLÈTEMENT ADHÉRÉE,
SOLIN CHEVAUCHANT AVANT FINITION DE
TÔLE DE TOITURE EN ALUMINIUM DE
CALIBRE 22
MEMBRANE PARE-AIR CONT (SCELLER TOUS
LES JOINTS AVEC RUBAN ADHÉSIF)
MEMBRANE PARE-AIR CONT (SCELLER TOUS
LES JOINTS AVEC RUBAN ADHÉSIF).
ASSURER CONTINUITÉ AUTOUR DU PHARE
REVÊTEMENT CONTRE-PLAQUÉ ÉPAISSEUR
19, CLASSÉ POUR APPLICATION EXTÉRIEUR
ENCADREMENT DE PORTE EN ALUMINIUM SOUDÉ AUX
MEMBRES STRUCTURAUX (ATTIQUE ET MONTANT)
PORTE EXTÉRIEURE EN ALUMINIUM
ALUMINIUM SOUDÉ AU CADRE DE PORTE
ENCADREMENT DE PORTE EN
ALUMINIUM HSS102x102x4.8
BANDE DE DÉMARRAGE
POSER FEUILLE D'ALUMINIUM
D'ÉPAISSEUR 6.4 UNE DISTANCE
VERTICALE DE 152.4mm (MIN) SUR LE MUR
REVÊTEMENT EXTÉRIEUR DE
SYSTÈME D'ENCLENCHEMENT
CAPE COD NAILITE EASY-UP
MEMBRANE COMPLÈTEMENT ADHÉRÉE,
SOLIN CHEVAUCHANT AVANT FINITION
DE TÔLE DE TOITURE EN ALUMINIUM DE
CALIBRE 22
MEMBRANE PARE-AIR CONT (SCELLER
TOUS LES JOINTS AVEC RUBAN ADHÉSIF)
MEMBRANE PARE-AIR CONT
(SCELLER TOUS LES JOINTS AVEC
RUBAN ADHÉSIF). ASSURER
CONTINUITÉ AUTOUR DU PHARE
REVÊTEMENT CONTRE-PLAQUÉ
ÉPAISSEUR 19, CLASSÉ POUR
APPLICATION EXTÉRIEUR
OUVERTURE 1220 x 762
FENÊTRE EN
VINYLE
SOLIN PRÉ-FINITION (CALIBRE 24),
FOURNIR BILLE CONT DE
SCELLANT/ADHÉSIF
CORDON DE REMPLISSAGE ET
SCELLANT TOUT AUTOUR SAUF SUR LE
SOLIN EN MÉTAL POUR PERMETTRE
DRAINAGE
MEMBRANE DE SOLIN COMPLÈTEMENT
ADHÉRÉ (2 BANDES) AUTOUR DE LA
FENÊTRE (COUCHE INTERNE
RECOUVRANT LES BRIDES DE FENÊTRE
ET COUCHE EXTERNE RECOUVRANT
SOLIN PRÉ-FINITION EN ALUMINIUM)
FENÊTRE EN VINYLE
CORDON DE REMPLISSAGE ET
SCELLANT TOUT AUTOUR
CHEVAUCHER LES BRIDES DU
RUBAN DE RACCORDEMENT
AU JOINT EN J POUR
PRÉVENIR L'INFILTRATION DE
L'EAU
BORDURE EN VINYLE SOLIDE
SCELLANT À LA BORDURE EN J
OU
VE
RT
UR
E 1220
OUVERTURE DE FENÊTRE SITUÉE
À LA MI HAUTEUR DE LA SECTION MODULAIRE 2
ENCADREMENT
DE PORTE EN
ALUMINIUM
HSS102x102x4.8
ENCADREMENT DE PORTE EN
ALUMINIUM HSS102x102x4.8
ENCADREMENT DE FENÊTRE EN
ALUMINIUM HSS102x102x4.8
LANTERNE FOURNIE PAR GARDE CÔTIÈRE
DU CANADA
ENCADREMENT DE FENÊTRE EN
ALUMINIUM HSS102x102x4.8
MEMBRANE PARE-AIR CONT
(SCELLER TOUS LES JOINTS).
ASSURER CONTINUITÉ AUTOUR
DU PHARE
POTEAU DE COIN INTÉRIEUR
CHEVAUCHER LES BRIDES DU
RUBAN DE RACCORDEMENT
AU POTEAU DE COIN POUR
ASSURER PRÉVENIR
L'INFILTRATION D'EAU
REVÊTEMENT EXTÉRIEUR DE
SYSTÈME D'ENCLENCHEMENT
CAPE COD NAILITE EASY-UP
BORDURE EN VINYLE
SOLIDE
SCELLANT À LA
BORDURE EN J
FENÊTRE EN VINYLE
CORDON DE REMPLISSAGE
ET SCELLANT TOUT
AUTOUR
PLAQUE D'ATTACHE EN ALUMINIUM
ÉPAISSEUR 6.4 SOUDÉE À
L'ENCADREMENT
ENCADREMENT DE PORTE EN
ALUMINIUM HSS102x102x4.8
MEMBRANE PARE-AIR CONT
(SCELLER TOUS LES JOINTS).
ASSURER CONTINUITÉ AUTOUR
DU PHARE
BASE
REVÊTEMENT CONTRE-PLAQUÉ
ÉPAISSEUR 19, CLASSÉ POUR
APPLICATION EXTÉRIEUR
FOURNIR CORDON DE REMPLISSAGE ET
SCELLANT ENTRE REVÊTEMENT ET PORTE
ENVELOPPER LA MEMBRANE SUR LA STRUCTURE (TYP)
SOLIN EN MÉTAL PRÉFINI DE CALIBRE 24
CONTINUE POSER PAR-DESSUS MEMBRANE
430
SCALE 1:50
0.5 1 20.750.50
SCALE 1:10
0.25
1
millimètresmillimeters
12111098754321056
CAD PRODUCED DRAWING
PRODUIT PAR DAO
4
A
B
D
Vendor Information / Sous-traitant
Pêches et Océans
Canada
Garde côtière
Canadienne
Fisheries and Oceans
Canada
Canadian
Coast Guard
C
23
scale - échelle
date
CCG ref. no. - no. réf. GCC
approved - approuvé
drawing no. - no. dessin sheet-feuille
designed - conception
date
drawn - dessiné
date
Asset - Actif
rev
by
datedescription
A1
Drawing - Dessin
rev-rév
par
checked - vérifié date
poucesinches
654210
REPORT ANY ERRORS OR OMISSIONS TO ILS MANAGER
SIGNALER LES ERREURS OU LES OMISSIONS AU GESTIONNAIRE SLI
File
/ F
ich
ie
r: 1
81
-1
59
56
-0
0_
AL
UM
IN
UM
L
IG
HT
HO
US
E - S
40
0.D
WG - Printed / Imprimé: 2
01
9/0
6/1
3 1
0:2
7
t. 613.829.2800
wsp.com
2611 Queensview Drive
Ottawa, ON Canada
Suite 300
K2B 8K2
f. 613.829.8299
CANADIAN COAST GUARD ALUMINIUM
LIGHTHOUSE MODULAR STRUCTURE
GARDE CÔTIÈRE CANADIENNE PHARE
EN ALUMINIUM, STRUCTURE MODULAIRE
DÉTAILS DE BÂTIMENT
TDH
WDD
SLH
IJF
181-15956-00 N/A
S400F
S400F
S400F
01/09 0
TSH 2019/03/29
ISSUED FOR 100% DESIGN REVIEW
SOUMIS POUR RÉVISION DE
CONCEPTION 100%
TSH 2019/05/23
ISSUED FOR 100% DESIGN
SOUMIS POUR CONCEPTION 100%
TSH 2019/02/19
ISSUED FOR 60% REVIEW
SOUMIS POUR RÉVISION 60%
2
3
1
ISSUED FOR CONSTRUCTIONFOR CANADIAN COAST GUARD USE IN THE
INTENDED REGIONS ONLY
SOUMIS POUR CONSTRUCTIONPOUR L'UTILISATION DE LA GARDE COTIERE CANADIENNE
DANS LES REGIONS PREVUESSEULEMENT
Samer Jabbour
134865