a spectacular leap in energy saving innovation. working to reduce the running costs of both...
TRANSCRIPT
A SPECTACULAR LEAPIN ENERGY SAVING
INNOVATION
Working to reduce the running costs of both air-conditioning and commercial
refrigeration
World leading technology available now
30% or more energy savings on all gas refrigerant compressor systems
Designed for manufacturers to be built in to new air conditioning and chiller systems
Works with and integrates into new or existingair-conditioners, refrigerated vending machines, refrigerated food and beverage display coolers for
commercial establishments,Refrigerated shipping containers (not freezers)
Optimized Refrigerant Supply - ORS
Uses our Patent Pending “Dual Sensor” technology in accurately controlling the desired temperature as well as the compressor work load. This maximizes
efficiency and minimizes compressor run time
Warm AirCold Air
Standard thermostats only measure the area temperature and keep the compressor running until the temperature has reached the desired level
This wastes considerable energy and it can lead toicing up of the evaporator coil
Warm AirCold Air
By measuring both the warm air
temperature
And the evaporator
coil temperature
COOLNOMIX can automatically calculate the most efficient compressor run time to maintain temperatures and reduce running
costs.
COOLNOMIX - THE ART OF COOL!
Steady temperature controlEfficient compressor operationNo evaporator icingFast return on investment
Case Study 1 – Air-conditioningMajor Thailand banking groupResponse to country wide energy crisisTesting at two branches-one large, one medium-sizedMix of large package based and split type units30%+ energy savings at 23 deg C set pointCOOLNOMIX rollout now planned to 800+ branchesNow in discussion with other organisation's e.g. 7-Eleven
Case Study 2 - RefrigerationHong Kong based fresh fruit juice manufacturer750 square foot walk in refrigerator44% energy saving with removal of four hourly heating to de-
ice evaporator coilCOOLNOMIX now fitted to all walk in refrigeratorsSignificant temperature problems at retail outlets in Shanghai
and elsewhere that limit the shelf life of their product. This company is now our agent in Shanghai
Case Study 2 - Result
Case Study 3 – Air ConditioningMalaysia based installation of COOLNOMIX AC-01Outside air temperature 33-34 deg CResults obtained in testing
Room temperature 22 deg C - 27.5% energy savingRoom temperature 23 deg C - 44% energy savingRoom temperature 24 deg C - 71% energy savingRoom temperature 25 deg C - Not tested (too hot!)
Supplied By NuVision EnergyQueensgate House