16
G38 HP10M 1000V DC Midget (10x38mm) Photovoltaic Fuses Catalog Numbers (amps) Dimensions HP10M1 HP10M8 HP10M2 HP10M10 HP10M3 HP10M12 HP10M3½ HP10M15 HP10M4 HP10M20 HP10M5 HP10M25 HP10M6 HP10M30 HP10M7 HP10M32 Approvals: UL Listed to Standard UL2579 File E333668 CSA Component Certified C22.2 IEC 60269-6 Approved Ratings: Volts : 1000VDC Amps : 1 to 32A IR : 50kA I.R. DC MBC : 1.35 x In Photovoltaic Fuse, gPV Applications: All photovoltaic applications PV string/array level protection Combiner box applications In-line PV module protection Inverters Battery charge controllers Features/Benefits: Low fault current interrupting capability Durable construction for enhanced system longevity Temperature cycle withstand capability Guaranteed operation at temperature extremes Industries first UL Listed Solution Globally accepted Engineered to protect photovoltaic applications Mersen’s HP10M photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10M, designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen’s Helio Protection fuse line. Catalog Numbers - Fuseholder UltraSafe™ Non-Indicating UltraSafe™ Indicating Screw Type USM1HEL USM1IHEL Spring Type USGM1HEL USGM1IHEL For additional information, view catalog page H2, USCC & USM UltraSafe TM Fuseholders.

Upload: others

Post on 18-Jan-2021

6 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

G38

HP10M 1000V DC Midget (10x38mm) Photovoltaic Fuses

Catalog Numbers (amps)

Dimensions

HP10M1 HP10M8

HP10M2 HP10M10

HP10M3 HP10M12

HP10M3½ HP10M15

HP10M4 HP10M20

HP10M5 HP10M25

HP10M6 HP10M30

HP10M7 HP10M32 Approvals: • UL Listed to Standard UL2579

File E333668 • CSA Component Certified C22.2 • IEC 60269-6 Approved

Ratings:Volts : 1000VDCAmps : 1 to 32AIR : 50kA I.R. DCMBC : 1.35 x In Photovoltaic Fuse, gPV

Applications: • All photovoltaic applications • PV string/array level protection • Combiner box applications • In-line PV module protection • Inverters • Battery charge controllers

Features/Benefits: ● Low fault current interrupting capability

● Durable construction for enhanced system longevity

● Temperature cycle withstand capability

● Guaranteed operation at temperature extremes

● Industries first UL Listed Solution ● Globally accepted

Engineered to protect photovoltaic applicationsMersen’s HP10M photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10M, designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen’s Helio Protection fuse line.

Catalog Numbers - FuseholderUltraSafe™ Non-Indicating

UltraSafe™ Indicating

Screw Type USM1HEL USM1IHEL

Spring Type USGM1HEL USGM1IHEL

For additional information, view catalog page H2, USCC & USM UltraSafeTM Fuseholders.

Page 2: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

��������������� ���� ����������������������� !���"!�!#!$��%&����$%&��%!'�()��� *�+( �,��-��� ����.�/�0�1���, 0�/���/0��1�/�0� 0���*��, ��1������,)�0����1��2���3��42������5��*�6� ���7��,��3�5�/�/2��3�1��)� 3���/��1���1�����2���38��)�1)�/������ �9�� ���//�������0� 1� ����, ��1����:4�1;+�,�.���<�/���������)�*)��) �+1� 1�������)����/=�()������ *��, ��1��0��/�0�1���� �������4���. ������-��,,��1�����>��� *�+�1���8� .�,���/�����/+�����:?+* �/<�@A�������������=AB(BCDE�FG6HIJ�K�@IAJL�(LDF��!M�&�����%�� &���$!��'��N�� �� ���'&��'��N�� '!O�! ��!$�� �&�# �&&� %��P�QRS�TU�V %'�QRS�TU�V ���W�%' ���!���%'M%&��!� ���$�&���'��&����%M��XYZ[\Z]̂__̀a]b[Ycdbe XYZYfghijkiilgmZl g f kiilno piqr hiqr fiqr s[ftiql uv XZfghijkiilgmZlXYZYfghijkiilgmZlw g f kiilno piqr hiqr fiqr s[ftiql xby XZfghijkiilgmZlXYZYfghijkiilgxZl z{ifip{z { kiilno piiqr hiqr fiqr s[ftkql uv XZfghijkiilgZlXYZYfghijkiilgxZlw z{ifip{| { kiilno piiqr hiqr fiqr s[ftkql xby XZfghijkiilgZlXYZYfghijpiiilgxZl z{ifiphi { piiilno }iqr hiqr fiqr s[{tiql uv XZfghijpiiilgZlXYZYfghijpiiilgxZlw z{ifiphp { piiilno }iqr hiqr fiqr s[{tiql xby XZfghijpiiilgZlXYZYfghijp}iilgxZl z{ifip}z { p}iilno k}qr hiqr fiqr s[}tiql uv XZfghijp}iilgZlXYZYfghijp}iilgxZlw z{ifip}| { p}iilno k}qr hiqr fiqr s[}tiql xby XZfghijp}iilgZlB��JD-BC�� GC�~����(2,���AB8�I�������� IF�����+~~8��-�(2,����� LIA��~���+~8�A�����LL�� G(I�A��~+���+�~B@@L(LDFBC��IAL�LAB(LDF�����������������������������������+���A�������A����������������1 ���A�*��������������� ����¡������F3¢����£������������B¤E�:������33�<����*���1�/�1� ¢������������¥���A����/¥�� ��/�/�1,,� u¦ §̈ov©©vª§§uo§« X̂a©¬ª¬̀­̂®b[X̄¬­°±pf}[lrog{r[©̀²X¬_ª̀][³¬®b[́̀ª_bµ[¶ph[­v[¶{i[r³·[\iti}[­v[ft}©©fe6LAJD¤L(A¸�:6<�¹�JI6D(I�LF@LAB(LDF�� (� 3�����( 9����=���F3�� A��=�4�������A33���FD�º�� /�1��»���8����, ��1��/�� A��=�4�������A33���FA�º�� /�1�������8�, ��1��/¼�½�¾�����¿����À� ���Á�Â����¾¾������Ã�������¾Ä�J�3�����*�����*�����0����4���������� *�+( �,�, /�1����)����,�1�.2��� �3�����/�1�� =�Åv®[̀ÆƬ­¬vª̀][¬ªÇv®©̀­¬vª[̀av̂­[X̂®_bgY®̀d[X̂®_b[Z®v­b°­¬Èb[nbȬ°by[Ȭy¬­[bdt©b®ybªt°v©

Page 3: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

Surge-Trap® Pluggable Type 2 - 40 kA

IEC SPD

www.ep.mersen.com 1

MER

SEN

res

erve

s th

e ri

gh

t to

ch

ang

e, u

pd

ate

or c

orre

ct, w

ith

out

not

ice,

an

y in

form

atio

n c

onta

ined

in t

his

dat

ash

eet.

DIN Rail IEC Type 2 / Class IISTP T2 40 is the series of Type 2/Class II devices for discharging voltage surges, in accordance with EN/IEC 61643. Suitable for the second stage of protection in supply distribution panels in which Type 1 protection devices are installed upstream, or for the first stage of protection in commercial or other applications not exposed to direct strikes and with no external lightning protection system.

Features Benefits z Maximum discharge current (8/20μs): 40kA per phase z Nominal discharge current (8/20μs): 20kA per phase z TNS, TNC, TT and IT networks z Un(L-N/L-L): 48V, 60V, 120/208V, 230/400V, 277/480V, 400/690V & higher z DIN-rail mountable, plug-in format z Visual and remote end of life indicators z Reversible chassis to allow cable entry from above or below z Mechanically coded cartridges to avoid cartridge replacement errors

Applications z Industry and automation z Commercial and residential installations z Telecom & IT & Data Centers z LED outdoor lighting z Water treatment z Smart grid & LV Metering z Photovoltaic & wind

StandardsIEC 61643-1EN 61643-11

Technical data overviewClass Type 2 / Class II

Un 48V, 60V, 120/208V, 230/400V, 277/480V

Imax 40 kA

In (8/20) 20 kA

Body Material PA66 CT1; V-0

System type TT, TNS, TNC, IT

Number of Poles 1,2,3,4

Format Pluggable

Temperature range -40 ... 80 ° C

Icc 25 kA

IP Code 20

Back-up fuse 125 A gG

Stranded wire Section 6 ... 25 mm²

Rigid wire Section 6 ... 35 mm²

Response Time 25 ns

/ DS-SPDPT240PV-05-0715_EN

Page 4: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

Surge-Trap® Pluggable Type 2 - 40 kA

IEC SPD

www.ep.mersen.com 2

MER

SEN

res

erve

s th

e ri

gh

t to

ch

ang

e, u

pd

ate

or c

orre

ct, w

ith

out

not

ice,

an

y in

form

atio

n c

onta

ined

in t

his

dat

ash

eet.

1 Pole

Catalognumber

Referencenumber Un Uc Imax (8/20) In (8/20) Up at In Remote

Cartridge No

L-N N-PE

L-N (1Ph)STPT2-40K150V-1P 83020104 120 VAC 150 V 40 kA 20 kA ≤ 0.9 kV No SP2-40K150V -

STPT2-40K150V-1PM 83020105 120 VAC 150 V 40 kA 20 kA ≤ 0.9 kV Yes SP2-40K150V -

STPT2-40K275V-1P 83020106 230 VAC 275 V 40 kA 20 kA ≤ 1.3 kV No SP2-40K275V -

STPT2-40K275V-1PM 83020107 230 VAC 275 V 40 kA 20 kA ≤ 1.3 kV Yes SP2-40K275V -

STPT2-40K320V-1P 83020108 277 VAC 320 V 40 kA 20 kA ≤ 1.4 kV No SP2-40K320V -

STPT2-40K320V-1PM 83020109 277 VAC 320 V 40 kA 20 kA ≤ 1.4 kV Yes SP2-40K320V -

STPT2-40K440V-1P 83020110 400 VAC 440 V 40 kA 20 kA ≤ 2 kV No SP2-40K440V -

STPT2-40K440V-1PM 83020111 400 VAC 440 V 40 kA 20 kA ≤ 2 kV Yes SP2-40K440V -

STPT2-30K750V-1P 83020100 690 VAC 750 V 30 kA 15 kA ≤ 3 kV No SP2-30K750V -

STPT2-30K750V-1PM 83020101 690 VAC 750 V 30 kA 15 kA ≤ 3 kV Yes SP2-30K750V -

N-PE (N)STPT2-40K-N 83020112 Neutral 265 V 40 kA 20 kA ≤ 1.5 kV No - SP2-40K-N

STPT2-40K275V-1PM

Product range

/ DS-SPDPT240PV-05-0715_EN

Page 5: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

Surge-Trap® Pluggable Type 2 - 40 kA

IEC SPD

www.ep.mersen.com 3

MER

SEN

res

erve

s th

e ri

gh

t to

ch

ang

e, u

pd

ate

or c

orre

ct, w

ith

out

not

ice,

an

y in

form

atio

n c

onta

ined

in t

his

dat

ash

eet.

2 Poles

Catalognumber

Referencenumber Un Uc

Imax (8/20) In (8/20) Up at In Remote

Cartridge No

L-N N-PE

TT (1Ph+N)

STPT2-40K150V-2PG 83020114 120 VAC 150 V 40 kA 20 kA ≤ 0.9 kV (L-N)≤ 1.5 kV (N-PE) No SP2-40K150V SP2-40K-N

STPT2-40K150V-2PGM 83020115 120 VAC 150 V 40 kA 20 kA ≤ 0.9 kV (L-N)≤ 1.5 kV (N-PE) Yes SP2-40K150V SP2-40K-N

STPT2-40K275V-2PG 83020116 230 VAC 275 V 40 kA 20 kA ≤ 1.3 kV (L-N)≤ 1.5 kV (N-PE) No SP2-40K275V SP2-40K-N

STPT2-40K275V-2PGM 83020117 230 VAC 275 V 40 kA 20 kA ≤ 1.3 kV (L-N)≤ 1.5 kV (N-PE) Yes SP2-40K275V SP2-40K-N

STPT2-40K320V-2PG 83020118 277 VAC 320 V 40 kA 20 kA ≤ 1.4 kV (L-N)≤ 1.5 kV (N-PE) No SP2-40K320V SP2-40K-N

STPT2-40K320V-2PGM 83020119 277 VAC 320 V 40 kA 20 kA ≤ 1.4 kV (L-N)≤ 1.5 kV (N-PE) Yes SP2-40K320V SP2-40K-N

TNS (1Ph+N)STPT2-40K60V-2P 83020128 48 VAC 60 V 40 kA 20 kA ≤ 0.7 kV No SP2-40K60V -

STPT2-40K60V-2PM 83020129 48 VAC 60 V 40 kA 20 kA ≤ 0.7 kV Yes SP2-40K60V -

STPT2-40K75V-2P 83020130 60 VAC 75 V 40 kA 20 kA ≤ 0.8 kV No SP2-40K75V -

STPT2-40K75V-2PM 83020131 60 VAC 75 V 40 kA 20 kA ≤ 0.8 kV Yes SP2-40K75V -

STPT2-40K150V-2P 83020120 120 VAC 150 V 40 kA 20 kA ≤ 0.9 kV No SP2-40K150V -

STPT2-40K150V-2PM 83020121 120 VAC 150 V 40 kA 20 kA ≤ 0.9 kV Yes SP2-40K150V -

STPT2-40K275V-2P 83020122 230 VAC 275 V 40 kA 20 kA ≤ 1.3 kV No SP2-40K275V -

STPT2-40K275V-2PM 83020123 230 VAC 275 V 40 kA 20 kA ≤ 1.3 kV Yes SP2-40K275V -

STPT2-40K320V-2P 83020124 277 VAC 320 V 40 kA 20 kA ≤ 1.4 kV No SP2-40K320V -

STPT2-40K320V-2PM 83020125 277 VAC 320 V 40 kA 20 kA ≤ 1.4 kV Yes SP2-40K320V -

IT (Ph+N)TNS (1Ph+N)

STPT2-40K440V-2P 83020126 230 VAC (IT)400 VAC (TNS) 440 V 40 kA 20 kA ≤ 2 kV No SP2-40K440V -

STPT2-40K440V-2PM 83020127 230 VAC (IT)400 VAC (TNS) 440 V 40 kA 20 kA ≤ 2 kV Yes SP2-40K440V -

STPT2-40K275V-2PM

Product range

/ DS-SPDPT240PV-05-0715_EN

Page 6: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

Surge-Trap® Pluggable Type 2 - 40 kA

IEC SPD

www.ep.mersen.com 4

MER

SEN

res

erve

s th

e ri

gh

t to

ch

ang

e, u

pd

ate

or c

orre

ct, w

ith

out

not

ice,

an

y in

form

atio

n c

onta

ined

in t

his

dat

ash

eet.

3 Poles

Catalognumber

Referencenumber Un Uc Imax (8/20) In (8/20) Up at In Remote

Cartridge No

L-N

TNC (3Ph)STPT2-40K150V-3P 83020132 208 VAC 150 V 40 kA 20 kA ≤ 0.9 kV No SP2-40K150V

STPT2-40K150V-3PM 83020133 208 VAC 150 V 40 kA 20 kA ≤ 0.9 kV Yes SP2-40K150V

STPT2-40K275V-3P 83020134 400 VAC 275 V 40 kA 20 kA ≤ 1.3 kV No SP2-40K275V

STPT2-40K275V-3PM 83020135 400 VAC 275 V 40 kA 20 kA ≤ 1.3 kV Yes SP2-40K275V

STPT2-40K320V-3P 83020136 480 VAC 320 V 40 kA 20 kA ≤ 1.4 kV No SP2-40K320V

STPT2-40K320V-3PM 83020137 480 VAC 320 V 40 kA 20 kA ≤ 1.4 kV Yes SP2-40K320V

STPT2-30K750V-3P 83020102 690 VAC1000 VAC 750 V 30 kA 15 kA ≤ 3 kV No SP2-30K750V

STPT2-30K750V-3PM 83020103 690 VAC1000 VAC 750 V 30 kA 15 kA ≤ 3 kV Yes SP2-30K750V

IT (3Ph)TNC (3Ph)

STPT2-40K440V-3P 83020142 400 VAC (IT)690 VAC (TNC) 440 V 40 kA 20 kA ≤ 2 kV No SP2-40K440V

STPT2-40K440V-3PM 83020143 400 VAC (IT)690 VAC (TNC) 440 V 40 kA 20 kA ≤ 2 kV Yes SP2-40K440V

STPT2-40K275V-3PM

Product range

/ DS-SPDPT240PV-05-0715_EN

Page 7: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

Surge-Trap® Pluggable Type 2 - 40 kA

IEC SPD

www.ep.mersen.com 5

MER

SEN

res

erve

s th

e ri

gh

t to

ch

ang

e, u

pd

ate

or c

orre

ct, w

ith

out

not

ice,

an

y in

form

atio

n c

onta

ined

in t

his

dat

ash

eet.

Product range

4 Poles

Catalognumber

Referencenumber Un Uc

Imax (8/20) In (8/20) Up at In Remote

Cartridge No

L-N N-PE

TT (3Ph+N)

STPT2-40K150V-4PG 83020144 120/208 VAC 150 V 40 kA 20 kA ≤ 0.9 kV (L-N)≤ 1.5 kV (N-PE) No SP2-40K150V SP2-40K-N

STPT2-40K150V-4PGM 83020145 120/208 VAC 150 V 40 kA 20 kA ≤ 0.9 kV (L-N)≤ 1.5 kV (N-PE) Yes SP2-40K150V SP2-40K-N

STPT2-40K275V-4PG 83020146 230/400 VAC 275 V 40 kA 20 kA ≤ 1.3 kV (L-N)≤ 1.5 kV (N-PE) No SP2-40K275V SP2-40K-N

STPT2-40K275V-4PGM 83020147 230/400 VAC 275 V 40 kA 20 kA ≤ 1.3 kV (L-N)≤ 1.5 kV (N-PE) Yes SP2-40K275V SP2-40K-N

STPT2-40K320V-4PG 83020148 277/480 VAC 320 V 40 kA 20 kA ≤ 1.4 kV (L-N)≤ 1.5 kV (N-PE) No SP2-40K320V SP2-40K-N

STPT2-40K320V-4PGM 83020149 277/480 VAC 320 V 40 kA 20 kA ≤ 1.4 kV (L-N)≤ 1.5 kV (N-PE) Yes SP2-40K320V SP2-40K-N

TNS (3Ph+N)STPT2-40K150V-4P 83020150 120/208 VAC 150 V 40 kA 20 kA ≤ 0.9 kV No SP2-40K150V -

STPT2-40K150V-4PM 83020151 120/208 VAC 150 V 40 kA 20 kA ≤ 0.9 kV Yes SP2-40K150V -

STPT2-40K275V-4P 83020152 230/400 VAC 275 V 40 kA 20 kA ≤ 1.3 kV No SP2-40K275V -

STPT2-40K275V-4PM 83020153 230/400 VAC 275 V 40 kA 20 kA ≤ 1.3 kV Yes SP2-40K275V -

STPT2-40K320V-4P 83020154 277/480 VAC 320 V 40 kA 20 kA ≤ 1.4 kV No SP2-40K320V -

STPT2-40K320V-4PM 83020155 277/480 VAC 320 V 40 kA 20 kA ≤ 1.4 kV Yes SP2-40K320V -

IT (3Ph+N)TNS (3Ph+N)

STPT2-40K440V-4P 83020156 230/400 VAC (IT)400/690 VAC (TNS) 440 V 40 kA 20 kA ≤ 2 kV No SP2-40K440V -

STPT2-40K440V-4PM 83020157 230/400 VAC (IT)400/690 VAC (TNS) 440 V 40 kA 20 kA ≤ 2 kV Yes SP2-40K440V -

STPT2-40K275V-4PM

Replacement cartridgesCatalognumber

Referencenumber Un Uc Imax (8/20) In (8/20) Up at In

L-NSP2-40K60V 83020008 480 VAC 60 V 40 kA 20 kA ≤ 0.7 kV

SP2-40K75V 83020009 60 VAC 75 V 40 kA 20 kA ≤ 0.8 kV

SP2-40K150V 83020001 120 VAC 150 V 40 kA 20 kA ≤ 0.9 kV

SP2-40K275V 83020002 230 VAC 275 V 40 kA 20 kA ≤ 1.3 kV

SP2-40K320V 83020003 277 VAC 320 V 40 kA 20 kA ≤ 1.4 kV

SP2-40K440V 83020004 400 VAC 440 V 40 kA 20 kA ≤ 2 kV

SP2-30K750V 83020007 690 VAC 750 V 40 kA 20 kA ≤ 3 kV

N-PESP2-40K-N 83020000 Neutral 255 V 40 kA 20 kA ≤ 1.5 kV

SP2-40K275V

/ DS-SPDPT240PV-05-0715_EN

Page 8: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

Surge-Trap® Pluggable Type 2 - 40 kA

IEC SPD

www.ep.mersen.com 6

MER

SEN

res

erve

s th

e ri

gh

t to

ch

ang

e, u

pd

ate

or c

orre

ct, w

ith

out

not

ice,

an

y in

form

atio

n c

onta

ined

in t

his

dat

ash

eet.

Dimensions

Electrical diagrams

L-N (1Ph) N-PE (N) TT (1Ph+N) - 2PG TNS (1Ph+N) - 2P

IT (1Ph+N) - 2P TNC (3Ph) - 3P IT (3Ph) - 3P TT (3Ph+N) - 4PG

TNS (3Ph+N) - 4P

1 Pole 2 Poles 3 Poles 4 Poles

/ DS-SPDPT240PV-05-0715_EN

Page 9: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

20 Mersen • Surge-Trap® Solutions

SURGE-TRAP® !"#$ % &#'S ( &!# !% )*

3 poles Network Cartridge Id.

REFERENCE

NUMBER

CATALOG

NUMBER

SYSTEM

TYPE

ELECTRICAL

DIAGRAM

Un

[VAC]

Uc

[V]

Imax

+,-%*.

[KA]

In

+,-%*.

[KA]

Up@In

+,-%*.

[KV]

REMOTE

(M)L N

83020132 STPT2-40K150V-3P TNC (3Ph) H -/208 150 40 20 ≤0.9 C22 -

83020133 STPT2-40K150V-3PM TNC (3Ph) H -/208 150 40 20 ≤0.9 √ C22 -

83020134 STPT2-40K275V-3P TNC (3Ph) H -/400 275 40 20 ≤1.3 C23 -

83020135 STPT2-40K275V-3PM TNC (3Ph) H -/400 275 40 20 ≤1.3 √ C23 -

83020136 STPT2-40K320V-3P TNC (3Ph) H -/480 320 40 20 ≤1.4 C24 -

83020137 STPT2-40K320V-3PM TNC (3Ph) H -/480 320 40 20 ≤1.4 √ C24 -

83020142 STPT2-40K440V-3P IT (3Ph); TNC (3Ph) I -/400; -/690 440 40 20 ≤2 C25 -

83020143 STPT2-40K440V-3PM IT (3Ph); TNC (3Ph) I -/400; -/690 440 40 20 ≤2 √ C25 -

83020102 STPT2-30K750V-3P TNC (3Ph) H -/690; -/1000 750 30 15 ≤3 C26 -

83020103 STPT2-30K750V-3PM TNC (3Ph) H -/690; -/1000 750 30 15 ≤3 √ C26 -

H I J

Electrical diagrams

!"#$%!&' !"#$%!&' !"($%)&*' )"#$%)&'

4 poles Network Cartridge Id.

REFERENCE

NUMBER

CATALOG

NUMBER

SYSTEM

TYPE

ELECTRICAL

DIAGRAM

Un

[VAC]

Uc

[V]

Imax

+,-%*.

[KA]

In

+,-%*.

[KA]

Up@In

+,-%*.

[KV]

REMOTE

(M)L N

83020144 STPT2-40K150V-4PG TT (3Ph+N) J 120/208 150 40 20 ≤0.9 (L-N) ≤1.5 (N-PE) C22 C27

83020145 STPT2-40K150V-4PGM TT (3Ph+N) J 120/208 150 40 20 ≤0.9 (L-N) ≤1.5 (N-PE) √ C22 C27

83020146 STPT2-40K275V-4PG TT (3Ph+N) J 230/400 275 40 20 ≤1.3 (L-N) ≤1.5 (N-PE) C23 C27

83020147 STPT2-40K275V-4PGM TT (3Ph+N) J 230/400 275 40 20 ≤1.3 (L-N) ≤1.5 (N-PE) √ C23 C27

83020148 STPT2-40K320V-4PG TT (3Ph+N) J 277/480 320 40 20 ≤1.4 (L-N) ≤1.5 (N-PE) C24 C27

83020149 STPT2-40K320V-4PGM TT (3Ph+N) J 277/480 320 40 20 ≤1.4 (L-N) ≤1.5 (N-PE) √ C24 C27

83020150 STPT2-40K150V-4P TNS (3Ph+N) L 120/208 150 40 20 ≤0.9 C22

83020151 STPT2-40K150V-4PM TNS (3Ph+N) L 120/208 150 40 20 ≤0.9 √ C22

83020152 STPT2-40K275V-4P TNS (3Ph+N) L 230/400 275 40 20 ≤1.3 C23

83020153 STPT2-40K275V-4PM TNS (3Ph+N) L 230/400 275 40 20 ≤1.3 √ C23

83020154 STPT2-40K320V-4P TNS (3Ph+N) L 277/480 320 40 20 ≤1.4 C24

83020155 STPT2-40K320V-4PM TNS (3Ph+N) L 277/480 320 40 20 ≤1.4 √ C24

83020156 STPT2-40K440V-4PIT (3Ph+N); TNS (3Ph+N)

L230/400; 400/690

440 40 20 ≤2 C25

83020157 STPT2-40K440V-4PMIT (3Ph+N); TNS (3Ph+N)

L230/400; 400/690

440 40 20 ≤2 √ C25

REFERENCE

NUMBER

CATALOG

NUMBERNETWORK Un [VAC] Uc [V]

Imax +,-%*.

[KA]

In +,-%*.

[KA]

Up@In +,-%*.

[KV]

CARTRIDGE

ID.

83020008 SP2-40K60V L-N (1Ph) 48 60 40 20 ≤0.7 C20

83020009 SP2-40K75V L-N (1Ph) 60 75 40 20 ≤0.8 C21

83020001 SP2-40K150V L-N (1Ph) 120 150 40 20 ≤0.9 C22

83020002 SP2-40K275V L-N (1Ph) 230 275 40 20 ≤1.3 C23

83020003 SP2-40K320V L-N (1Ph) 277 320 40 20 ≤1.4 C24

83020004 SP2-40K440V L-N (1Ph) 400 440 40 20 ≤2 C25

83020007 SP2-30K750V L-N (1Ph) 690 750 30 15 ≤3 C26

83020000 SP2-40K-N N-PE (N) Neutral 265 40 20 ≤1.5 C27

Replacement cartridges

Page 10: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

Surge-Trap® Pluggable STPT2 Series - 40kA PV

Surge Protection for Solar-Photovoltaic Systems / DS-SPDPT240-05-0117_EN

EP.MERSEN.COM 1

ME

RS

EN

res

erve

s th

e ri

ght

to

cha

nge,

up

dat

e o

r co

rrec

t, w

itho

ut n

oti

ce, a

ny in

form

atio

n co

ntai

ned

in t

his

dat

ashe

et.

DC POWER LINE PROTECTION

STP T2 40 PV is the series of devices that provide advanced overvoltage protection to photovoltaic systems by utilizing Mersen’s optimized dynamic thermal disconnection system, which does not require additional overcurrent protection (back-up fuse) due to its high short-circuit withstand rating. These surge protective devices are suitable for all PV applications: large-scale, rooftop and self-consumption (off-grid) DC installations.

FEATURES & BENEFITS• Maximum discharge current

(8/20μs): 40 kA

• Nominal discharge current (8/20μs): 10 kA, 20 kA

• Ucpv: 65, 80, 660, 1060 Vdc and 1500 Vdc

• Iscpv: 10 kA (EN 50539-11), no back-up fuse required

• SCCR: 50 kA, 65 kA, 100 kA (UL 1449 3rd Ed)

• DIN-rail mountable, plug-in format

• Visual and remote end of life indica-tors

• Reversible chassis to allow cable entry from above or below

• Mechanically coded cartridges to avoid cartridge replacement errors

APPLICATIONS• Photovoltaic & wind

STANDARDS• EN 50539-11

• UL 1449 3rd Ed.

• UTE C 61-740-51

TECHNICAL DATA OVERVIEW

Class Type 2 EN 50539-11; Type 2 UL 1449 Voltage Range DC 660 ... 1500 VDCIscpv 10000 ASCCR 50 kA, 65 kA, 100 kABody Material PA6 CT1; V-0System type Y PV, U PVNumber of Poles 3, 2Format PluggableTemperature range -40 ... 85 ° CRigid wire Section 6 ... 35 mm²Response Time 25 ns

SURGE PROTECTION FOR SOLAR-PHOTOVOLTAIC SYSTEMS

Surge-Trap® Pluggable STPT2 Series - 40kA PV

Page 11: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

Surge-Trap® Pluggable STPT2 Series - 40kA PV

Surge Protection for Solar-Photovoltaic Systems / DS-SPDPT240-05-0117_EN

EP.MERSEN.COM 2

ME

RS

EN

res

erve

s th

e ri

ght

to

cha

nge,

up

dat

e o

r co

rrec

t, w

itho

ut n

oti

ce, a

ny in

form

atio

n co

ntai

ned

in t

his

dat

ashe

et.

Large-scale and rooftop PV

Catalognumber

Reference number

Number of poles/phases Ucpv Iscpv

Imax (8/20) In (8/20) Up at In Remote

Cartridge No

L-N

Y PVSTPT2-40K1000V-YPV 83020140 3 1060 VDC 10000 A 40 kA 20 kA ≤ 4 kV No SP2-40K1000V-PVSTPT2-40K1000V-YPVM 83020141 3 1060 VDC 10000 A 40 kA 20 kA ≤ 4 kV Yes SP2-40K1000V-PVSTPT2-40K1500V-YPV 83020158 3 1500 VDC 10000 A 40 kA 15 kA ≤ 5 kV No SP2-40K1500V-PVSTPT2-40K1500V-YPVM 83020159 3 1500 VDC 10000 A 40 kA 15 kA ≤ 5 kV Yes SP2-40K1500V-PVSTPT2-40K600V-YPV 83020138 3 660 VDC 10000 A 40 kA 20 kA ≤ 2.6 kV No SP2-40K600V-PVSTPT2-40K600V-YPVM 83020139 3 660 VDC 10000 A 40 kA 20 kA ≤ 2.6 kV Yes SP2-40K600V-PV

STPT2-40K1500V-YPVM

Self-consumption PV

Catalognumber

Reference number

Number of poles/phases Ucpv Iscpv Imax (8/20) In (8/20) Up at In Remote

Cartridge No

L-N

U PVSTPT2-40K60V-2P 83020128 2 65 VDC 1000 A 40 kA 20 kA ≤ 0.7 kV No SP2-40K60VSTPT2-40K60V-2PM 83020129 2 65 VDC 1000 A 40 kA 20 kA ≤ 0.7 kV Yes SP2-40K60VSTPT2-40K75V-2P 83020130 2 80 VDC 1000 A 40 kA 20 kA ≤ 0.8 kV No SP2-40K75VSTPT2-40K75V-2PM 83020131 2 80 VDC 1000 A 40 kA 20 kA ≤ 0.8 kV Yes SP2-40K75V

STPT2-40K75V-2PM

Replacement cartridges

Catalognumber

Reference number Ucpv Iscpv Imax (8/20) In (8/20) Up at In

PVSP2-40K1000V-PV 83020006 530 VDC 10000 A 40 kA 20 kA ≤ 2 kVSP2-40K1500V-PV 83020010 750 VDC 10000 A 40 kA 15 kA ≤ 2.5 kVSP2-40K600V-PV 83020005 330 VDC 10000 A 40 kA 20 kA ≤ 1.3 kVSP2-40K60V 83020008 65 VDC 1000 A 40 kA 20 kA ≤ 0.35 kVSP2-40K75V 83020009 80 VDC 1000 A 40 kA 20 kA ≤ 0.4 kV

SP2-40K1000V-PV

PRODUCT RANGE

Page 12: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

Surge-Trap® Pluggable STPT2 Series - 40kA PV

Surge Protection for Solar-Photovoltaic Systems / DS-SPDPT240-05-0117_EN

EP.MERSEN.COM 3

ME

RS

EN

res

erve

s th

e ri

ght

to

cha

nge,

up

dat

e o

r co

rrec

t, w

itho

ut n

oti

ce, a

ny in

form

atio

n co

ntai

ned

in t

his

dat

ashe

et.

DIMENSIONS

ELECTRICAL DIAGRAMS

Y PV U PV

3 Poles 2 Poles

Page 13: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

6/14/2019 FUSEHOLDERS, PHOTOVOLTAIC | UL Product iQ

https://iq.ulprospector.com/en/profile?e=59892 1/2

IZMR.E347822 - FUSEHOLDERS, PHOTOVOLTAIC

Fuseholders, Photovoltaic See General Information for Fuseholders, Photovoltaic MERSEN USA NEWBURYPORT-MA L L C E347822374 MERRIMAC STNEWBURYPORT, MA 01950-1930 USA

Cat. No.

Voltage Rating

Current Rating

Interrupting

Rating DC Amperes

Photovoltaic fuseholders

61041HPJ 1000 100 100,000

62041HPJ 1000 200 100,000

64041HPJ 1000 400 100,000

6641HPJ 1000 600 100,000

61006HPJ 1000 100 100,000

62001HPJ 1000 200 100,000

64031HPJ 1000 400 100,000

6631HPJ 1000 600 100,000

61016HPJ 1000 100 100,000

62011HPJ 1000 200 100,000

64011HPJ 1000 400 100,000

6611HPJ 1000 600 100,000

USM1HEL 1000 30 100kA

USM1IHEL 1000 30 100kA

USGM1HEL 1000 30 100KA

USGM1IHEL 1000 30 100KA

US6J 1000 60 10kA

HP15FHM32A, HP15FHM32B 1500 32 50kA

Page 14: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

6/14/2019 FUSEHOLDERS, PHOTOVOLTAIC | UL Product iQ

https://iq.ulprospector.com/en/profile?e=59892 2/2

CUS101HEL, CUS101IHEL, may be followed by additional suffixes, may be followedby N

1000 32 100kA

Trademark and/or Tradename: , , "FERRAZ SHAWMUT INC"

Last Updated on 2019-01-15

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufacturedunder UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-UpService. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The GuideInformation, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleadingmanner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permissionfrom UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the followingformat: "© 2019 UL LLC"

Page 15: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

6/14/2019 UL Certification: E468946 - Surge Protective Devices

https://iq.ulprospector.com/en/profile?e=161081 1/1

UL iQ for Surge Protective Devices

Surge Protective Devices E468946Guide Information

MERSEN FRANCE SB S A S15 RUE DE VAUCANSON, ST BONNET DE MURE 69720 FR

Cat No(s): STPT2-40K1000V-YPVSTPT2-40K1000V-Y

SPD Type

Volts (V)

AC/DC DC PV

Phase

Amps (A)

Ambient Min(°C)

Ambient Max(°C)

Mode

VPR (Vpk)

MLV (Vpk)

MCOV (V)

Vn (Vdc)

In (kA)

SCCR (kA)

Notes

2CA (4-2) 1000 DC PV - n/a - 85 DC+-DC- 3000 - 1000 - 20 50 2DC+-G 3000 - 1000 -DC--G 3000 - 1000 -

Evaluated to: UL 1449 4th Ed. Rev: 2016-03-17Note 2 - Suitable for Field and Factory wiring.

SPDs investigated for Type 1 applications are automatically suitable for Type 2 applications and may be marked for SPD Type 1 and/or Type 2 applications. SPDs onlymarked "SPD Type 2" are not suitable for Type 1 applications.

Where a minimum ambient temperature is not specified, assume 0°C unless the product is marked otherwise or with an Outdoor use Environmental Rating. See ElectricalEquipment for Use in Ordinary Locations (AALZ) for details regarding Environmental Ratings.

Report Date: 2014-06-16© 2019 UL LLCLast Revised: 2018-01-17

Page 16: HP10Mksquareenergy.com/wp-content/uploads/2019/09/Mersen-Datasheet-I… · • IEC 60269-6 Approved Ratings: Volts: 1000VDC Amps: 1 to 32A IR: 50kA I.R. DC MBC: 1.35 x In Photovoltaic

6/14/2019 FUSES FOR PHOTOVOLTAIC SYSTEMS | UL Product iQ

https://iq.ulprospector.com/en/profile?e=60292 1/1

JFGA.E333668 - FUSES FOR PHOTOVOLTAIC SYSTEMS

Fuses for Photovoltaic Systems See General Information for Fuses for Photovoltaic Systems MERSEN USA NEWBURYPORT-MA L L C E333668374 MERRIMAC STNEWBURYPORT, MA 01950-1930 USA

Cat. No.

Interrupting Capacity Rating

Volts Amps Volts Amps

  DC AC   DC AC  

HP6M 600 — 10,000 600 — 1-30

HP10M 1,000 — 50,000 1,000 — 1-64

HP10M(amp)CC 1,000 — 50,000 1,000 — 1-64

HP6J 600 — 10,000 600 — 61-600

HP10J 1,000 — 65,000 1,000 — 35-600

MEV100J 1,000 — 65,000 1,000 — 350-600

HP15G, HP15G(amp)VT, HP15G(amp)CC 1,500 — 10,000 1,500 — 5

HP15G, HP15G(amp)VT, HP15G(amp)CC 1,500 — 50,000 1,500 — 2-1/2 - 4

HP15M 1,500 — 50,000 1,500 — 4-50

HP15M(amp)CC 1,500 — 50,000 1,500 — 4-50

Trademark and/or Tradename: ,

Last Updated on 2019-03-19

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufacturedunder UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-UpService. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The GuideInformation, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleadingmanner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permissionfrom UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the followingformat: "© 2019 UL LLC"