a dimension print, kd800-1000 kd800, kd900, kd1000...
TRANSCRIPT
![Page 1: A DIMENSION PRINT, KD800-1000 KD800, KD900, KD1000 …resources.kohler.com/power/kohler/industrial/pdf/adv8868.pdf · a 8 7 6 5 4 3 2 1 b c d 8 7 6 5 4 3 2 1 a b c d title scale dwg](https://reader035.vdocuments.us/reader035/viewer/2022070907/5f7d4381fc7ebf2b734fb441/html5/thumbnails/1.jpg)
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEETDRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U.S.A.THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
H
370
[14.
6]
187 [7.4] 740[29.1]
75 [3.0
]
1411 [55.6] 75[3.0]
2116 [83.3]
75[3.0]
308
[12.
1]
195
[7.7
]
75 [3.0
]
4181 [164.6]
4125 [162.4]
3191 [125.6]
2499 [98.4]
1748 [68.8]
1449 [57.1]
841[33.1]
185
[7.3
]
HORIZONTAL CG
1795
[70.
7]
819
[32.
3]VE
RTI
CAL
CG
C
L
EG
A
K B
1102
[43.
4]FA
N C
L
F
D
98[3.8]
1061 [41.8]
535 *[21.1]
GENSET LENGTH
350[13.8]
85 [3.3
]
123 [4.8]
200
[7.9
]
338
[13.
3]
135
[5.3
]
255
[10.
0]
297
[11.
7]
2200
[86.
6]G
ENSE
T H
EIG
HT
J
M
1155[45.5]
A 11-3-16 (C-4) RADIATOR DIMENSIONS TABLE UPDATED [CT164327] CEKB 6-7-17 (B-8) 10X 25.4 [1.00] (GENSET & SUBBASE TANK
MOUNTING HOLES) WAS 16X; SEE SHEET 2 [CT175358] RRTC 10-10-17 (D-1) COLUMN M ADDED; (D-2) "RADIATOR
DIMENSIONS" TITLE REMOVED; (A-4) NOTE FOR DIMENSION "M" ADDED [CT180111] RRT
D 10-8-18 IMPERIAL DIMENSIONS ADDED TO ALL DIMENSIONS; SEE SHEET 2, 3, 4 & 5 [CT191046] ADP
E 2-19-20 (C-1,4) TABLE UPDATED; SEE SHEET 4 [CT202039] DS
NOTES:1) DIMENSIONS IN [] AREENGLISH EQUIVALENTS. 2) IF AN ENCLOSURE IS USED THE FUELLINE MUST BE STUBBED UP FROMDIRECTLY UNDER THE UNIT. REFERTO ENCLOSURE ADV. 3) IF IBC OR OSHPD CERTIFICATION IS REQUIRED SEE SEISMIC ADV FOR INSTALLATION INSTRUCTIONS. 4) IF SUBBASE FUEL TANK AND/ORENCLOSURE IS USED. REFER TOSUBBASE FUEL TANK/ENCLOSURE ADVTO DETERMINE MOUNTING LOCATION.
KD27V12KD800, KD900, KD1000
* REFER TO DIMENSION"M" FOR WIDTH OF THISMOUNTING HOLE
LEFT SIDEONLY WHEN ON BREAKERS
OR LOAD BUS AREPRESENT ON LEFT SIDE
CONDUIT ENTRY AREA FORGENETRATOR LOAD LEADS
(BOTTOM ENTRY)
SUGGESTED BLOCKHEATER CONDUITLOCATION
SUGGESTED 24VBATTERY CHARGERCONDUIT LOCATION
CONTROLLER CONDUIT UNDERSIDE COVER OF BOX
CONDUIT ENTRY FORLOAD CENTER
* KH05520TO4D ALTERNATOR EXTENDS PAST SKID
MOUNTING HOLES)(GENSET & SUBBASE TANK
25.4 [1.00]10X
1/2" NPTDRAIN
OIL
AND DIPSTICKENGINE OIL FILL
CORE OPENING
AIR
CIR
CU
ITC
OR
E H
EIG
HT
WAT
ER C
IRC
UIT
CO
RE
HEI
GH
T
RAD
IATO
R H
EIG
HT
JACKET WATERCORE WIDTH
FAN CENTER
GENSET WIDTH
RADIATOR WIDTH
AIR CIRCUITCORE WIDTH
MODEL ALT.GENSET MAXIMUM
WEIGHT (WET)(HORIZONTAL CG)
(WET)GENSETLENGTH
KD800 KH02970TO4D 6916 Kg [15248 LBS] 2185 [86] 4181 [164.6]KD800/900 KH03450TO4D 7155 Kg [15773 LBS] 2225 [87.6] 4181 [164.6]KD800/900/1000 KH04070TO4D 7457 Kg [16440 LBS] 2277 [89.6] 4181 [164.6]KD900/1000 KH04830TO4D 7770 Kg [17131 LBS] 2340 [92.1] 4181 [164.6]KD1000 KH05520TO4D 8083 Kg [17821 LBS] 2391 [94.1] 4224 [166.3]*
MODEL A B C D E F G H J K L M
KD800 50Hz FUELOPT
400[15.7]
1587[62.5]
1394[54.8]
674[26.5]
194[7.6]
747[29.4]
1487 [58.5]
674[26.5]
1494[58.8]
2030[79.9]
1924[75.7]
1688[66.4]
KD900/1000 50HzFUEL OPT
305[12.0]
1687[66.4]
1618[63.7]
899[35.4]
100[3.9]
859[33.8]
1587 [62.5]
674[26.5]
1718[67.6]
2099[82.6]
1941[76.4]
1850[72.8]
KD800 60Hz (50C COOLING)KD900/1000 60Hz(40C COOLING)
400[15.7]
1587[62.5]
1618[63.7]
674[26.5]
100[3.9]
859[33.8]
1487[58.5]
899[35.4]
1718[67.6]
2125[83.6]
1924[75.7]
1850[72.8]
KD900/1000 60Hz (50C COOLING)
306[12.0]
1687[66.4]
1844[72.6]
899[35.4]
100[3.9]
948[37.3]
1687[66.4]
899[35.4]
1896[74.6]
2100[82.6]
1986 [78.2]
1850[72.8]
PRO-EMETRIC
DIMENSION PRINT, KD800-10000.06 1 of 5
ADV-8868 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:X.XX X.X X SURFACE FINISHANGLES
APPROVALS DATE
SSS 9-8-16DJV 9-8-16
BMK 9-8-16
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
![Page 2: A DIMENSION PRINT, KD800-1000 KD800, KD900, KD1000 …resources.kohler.com/power/kohler/industrial/pdf/adv8868.pdf · a 8 7 6 5 4 3 2 1 b c d 8 7 6 5 4 3 2 1 a b c d title scale dwg](https://reader035.vdocuments.us/reader035/viewer/2022070907/5f7d4381fc7ebf2b734fb441/html5/thumbnails/2.jpg)
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEETDRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U.S.A.THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
474
[18.
7]
989[38.9]
1194[47.0]
ADP
1500
[59.
1]EX
HAU
ST O
UTL
ET
2510 [98.8]EXHAUST OUTLET
2565 [101.0]EXHAUST OUTLET
597
[23.
5]
EXH
AUST
OU
TLET
(2 P
LAC
ES)
961 [37.8]
122.8[4.83]140.0 [5.51]
D.B.C
89 [3.5
]
1691[66.6]
60°
225
*[8
.9]
1422 [56.0]*
1133[44.6]
861
[33.
9]
658
[25.
9]
3095 [121.8]*
357
*[1
4.1]
A 11-3-16 SEE SHEET 1 [CT164327] CEKB 6-7-17 (A-5), (B-8) FUEL SYSTEM NOTE UPDATED; SEE
SHEET 1 [CT175358] RRTC 10-10-17 SEE SHEET 1 [CT180111] RRTD 10-8-18 IMPERIAL DIMENSIONS ADDED TO ALL DIMENSIONS;
(D-5,6) 474 WAS 476, 989 WAS 995; (A-4,7) 658 WAS 644; (A-7) 1691 WAS 1730; SEE SHEET 1, 3, 4 & 5 [CT191046]
E 2-19-20 SEE SHEET 1 & 4 [CT202039] DS
FUEL INLETM22 X 1.5FUEL SYSTEM MATERIALSELECTION IS CRITICAL.SEE TP-5700 FOR DETAILS
KD27V12KD800, KD900, KD1000
6X M10 X 1.5
COOLANT DRAIN 15.8 [0.62]
*GENERATOR LIFT POINTSTO BE USED TO LIFTOPEN GENERATOR ONLY
24V BATTERYLOCATION
DETAILSTP-5700 FOR
IS CRITICAL. SEEMATERIAL SELECTION
FUEL SYSTEMM18-1.5 12L
FUEL RETURN
LOCATION OF ALTERNATORVOLTAGE REGULATOR
PRO-EMETRIC
DIMENSION PRINT, KD800-10000.09 2 of 5
ADV-8868 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:X.XX X.X X SURFACE FINISHANGLES
APPROVALS DATE
SSS 9-8-16DJV 9-8-16
BMK 9-8-16
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
EXHAUST OUTLET (GASKETS SUPPLIED WITH GENERATOR)SEE DETAIL P
DETAIL PSCALE 0.400
![Page 3: A DIMENSION PRINT, KD800-1000 KD800, KD900, KD1000 …resources.kohler.com/power/kohler/industrial/pdf/adv8868.pdf · a 8 7 6 5 4 3 2 1 b c d 8 7 6 5 4 3 2 1 a b c d title scale dwg](https://reader035.vdocuments.us/reader035/viewer/2022070907/5f7d4381fc7ebf2b734fb441/html5/thumbnails/3.jpg)
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEETDRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U.S.A.THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
1196[47.1]
2093[82.4]
210[8.3]
454
[17.
9]
473
[18.
6]39
7[1
5.6]
1173[46.2]
202[8.0]
260
[10.
3]
10-8-18ADP
1070
[42.
1]
1197[47.1]
60°TYP162.0
[6.38]
140.0 D.B.C[5.51]
482.0[18.98]
15°
30° TYP
12X 25.4[1.00]
431.8 D.B.C[17.00]
23°
45°TYP
8X 22.2[0.88]
342.9[13.50]
298.5 D.B.C[11.75]
162.0[6.38]
140.0 D.B.C[5.51]
30°
533
[21.
0]
60°TYP
474
[18.
6]
127.0[5.00]
1098[43.2]
666[26.2]
1950
[76.
8]
A 11-3-16 SEE SHEET 1 [CT164327] CEKB 6-7-17 SEE SHEET 1 & 2 [CT175358] RRTC 10-10-17 SEE SHEET 1 [CT180111] RRTD IMPERIAL DIMENSIONS ADDED TO ALL DIMENSIONS;
SEE SHEET 1, 2, 4 & 5 [CT191046]E 2-19-20 SEE SHEET 1 & 4 [CT202039] DS
SEE DETAIL R
SCALE 0.100
SEE DETAIL S
BLOCK HEATER(RIGHT SIDE GENSET)
BATTERY CHARGER(RIGHT SIDE GENSET)
STANDARD DUTY AIR CLEANER (RIGHT SIDE GENSET) KD27V12
KD800, KD900, KD1000
FLEXIBLE Y EXHAUST
NOTE:FLEXIBLE EXHAUST TO BE FULLY SUPPORTED BY EXTERNAL STRUCTURE(ALLOWED BENDING MOMENTAT EXHAUST FLANGE INTERFACELESS THAN 19 Nm)
RIGHT SIDE
BLOCK HEATER LOCATION
BATTERY CHARGER
DETAIL R
6X 11.1 X 22.1[0.44] [0.87]
SCALE 0.300
SCALE 0.280DETAIL U
6X 11.1 X 22.1[0.44] [0.87]
SCALE 0.180DETAIL T
DETAIL S
SCALE 0.120
SEE DETAIL T
SEE DETAIL U
SCALE 0.075
PRO-EMETRIC
DIMENSION PRINT, KD800-10000.15 3 of 5
ADV-8868 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:X.XX X.X X SURFACE FINISHANGLES
APPROVALS DATE
SSS 9-8-16DJV 9-8-16
BMK 9-8-16
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY- 9-8-16 NEW DRAWING [CT160432] SSS
![Page 4: A DIMENSION PRINT, KD800-1000 KD800, KD900, KD1000 …resources.kohler.com/power/kohler/industrial/pdf/adv8868.pdf · a 8 7 6 5 4 3 2 1 b c d 8 7 6 5 4 3 2 1 a b c d title scale dwg](https://reader035.vdocuments.us/reader035/viewer/2022070907/5f7d4381fc7ebf2b734fb441/html5/thumbnails/4.jpg)
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEETDRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U.S.A.THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
393
[15.
5]
996[39.2]
1183[46.6]
401
[15.
8]
2055.00[80.906]
ADP
679[26.7]
1165[45.9]
2343
[92.
2]
M
N
251
[9.9
]
1920[75.6]
99[3.9]
1834[72.2]
303[11.9]
375
[14.
8]
2054[80.9]
416
[16.
4]2417[95.1]
202[8.0]
904
[35.
6]
824
[32.
4]
75[3.0]
25[1.0]
198
[7.8
]35
0[1
3.8]
135[5.3]
350[13.8]
B 6-7-17 SEE SHEET 1 & 2 [CT175358] RRTC 10-10-17 SEE SHEET 1 [CT180111] RRTD 10-8-18 IMPERIAL DIMENSIONS ADDED TO ALL DIMENSIONS;
(A-4,5) 416 WAS 453, 996 WAS 995, 1183 WAS 1194; SEE SHEET 1, 2, 3 & 5 [CT191046]
E 2-19-20 (D-1,2) TABLE UPDATED; (C-4) PROJECTION VIEW ADDED; (D-2) 135, 350, 198 & (C-2) 350 DIMENSION ADDED; SEE SHEET 1 [CT202039] DS
HEAVY DUTY AIR CLEANER
KD27V12KD800, KD900, KD1000
(RIGHT SIDE GENSET)
DU
CT
FLAN
GE
OPE
NIN
G
DUCT FLANGE OPENING
DUCT FLANGE AND STONE GUARD
OIL LEVEL REGULATOR
AUTOMATIC OIL REPLENISHMENTSYSTEM
(LEFT SIDE GENSET)
CUSTOMER OIL SUPPLY CONNECTION 1/2" NPT(OIL RESERVOIRSUPPLIED BY CUSTOMER)
REDUNDANT STARTER
REDUNDANT STARTER, BATTERY RACK & CHARGER (RIGHT SIDE GENSET)
BATTERY RACK
REDUNDANT BATTERYCHARGER
REDUNDANTBATTERY RACK
M6 X 1.022 PLACES
DUCT FLANGE DIMENSIONSMODEL M N
KD800 50Hz FUELOPT
1685[66.3]
1492[58.7]
KD900/1000 50HzFUEL OPT
1796[70.7]
1718[67.6]
KD800 60Hz (50C COOLING)KD900/1000 60Hz (40C COOLING)
1685[66.3]
1716[67.5]
KD900/1000 60Hz (50C COOLING)
1796[70.7]
1895[74.6]
PRO-EMETRIC
DIMENSION PRINT, KD800-10000.05 4 of 5
ADV-8868 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:X.XX X.X X SURFACE FINISHANGLES
APPROVALS DATE
SSS 9-8-16DJV 9-8-16
BMK 9-8-16
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
NOTE:LEFT SIDE SKID MEMBER HIDDEN TO SHOWCONNECTION FROM OIL LEVEL REGULATOR TO OIL SUMP.
![Page 5: A DIMENSION PRINT, KD800-1000 KD800, KD900, KD1000 …resources.kohler.com/power/kohler/industrial/pdf/adv8868.pdf · a 8 7 6 5 4 3 2 1 b c d 8 7 6 5 4 3 2 1 a b c d title scale dwg](https://reader035.vdocuments.us/reader035/viewer/2022070907/5f7d4381fc7ebf2b734fb441/html5/thumbnails/5.jpg)
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEETDRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U.S.A.THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
IMPERIAL DIMENSIONS ADDED TO ALL DIMENSIONS; SEE SHEET 1, 2, 3 & 4 [CT191046] ADP
ALTERNATOR AIR FILTER INSTALLEDINSIDE OF LOUVERED PANELS
(7% DERATE ON GENERATOR RATING)
ALTERNATOR HEATER THREADSINTO REAR CASTING OF ALTERNATOR
ALTERNATOR AIR FILTER AND HEATER
963[37.9]
978
[38.
5]
366[14.4]
535
[21.
1]
625[24.6]
993[39.1]
148[5.8]
826[32.5]
282
[11.
1]
A 11-3-16 SEE SHEET 1 [CT164327] CEKB 6-7-17 SEE SHEET 1 & 2 [CT175358] RRTC 10-10-17 SEE SHEET 1 [CT180111] RRTD 10-8-18
E 2-19-20 SEE SHEET 1 & 4 [CT202039] DS
BASIC ELECTRICAL PACKAGE (BEP) LOAD CENTER
KD27V12KD800, KD900, KD1000
CIRCUIT BREAKER BOX(RIGHT AND/OR LEFT SIDE OPTION)
AIR FILTER RESTRICTION INDICATOR
AIR RESTRICTIONGAUGE
(RIGHT SIDE OF GENSET)
PRO-EMETRIC
DIMENSION PRINT, KD800-10000.06 5 of 5
ADV-8868 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:X.XX X.X X SURFACE FINISHANGLES
APPROVALS DATE
SSS 9-8-16DJV 9-8-16
BMK 9-8-16
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY- 9-8-16 NEW DRAWING [CT160432] SSS