A comparison of regulatory compliance approaches tofaçade fire risk in a prescriptive (UAE) and performance-
based (Australia) regulatory environment - The Good,the Bad and the Way forward
Mr. Faimeen F. Shah & Dr Amer Magrabi
![Page 2: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/2.jpg)
Agenda
• Background• Prescriptive compliance – United Arab Emirates (UAE)• Prescriptive & performance-based compliance – Australia• Summary & key recommendations• Questions
![Page 3: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/3.jpg)
Background
United Arab Emirates• Numerous façade fires• No fatalities but extensive
property damage• UAE Fire & Life Safety Code of
Practice revised:• Annexures – 2012-2014• Major update – 2017• Last revision - 2018
Australia• Lacrosse, Melbourne - 2014• Neo 200, Melbourne - 2019• Cladding Bans – NSW, VIC, QLD• BCA 2016 Amdt 1• BCA 2019• IEAust SFS Façade Practice Note 2019
![Page 4: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/4.jpg)
UAE – Prescriptive compliance
• UAE Fire and Life Safety Code ofPractice (2018 Editions)
• All buildings (unconditional)• Façade fire assessment report• Façade inspections• Excludes existing buildings• AHJ – Local Civil Defence
![Page 5: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/5.jpg)
UAE – Approvals process
Fire Safety Strategy(Report & Drawings)
AHJ (Civil Defence)preliminary NOC(excludes façade)
Workshopdocumentation (byFaçade Contractor)
Façade FireAssessment Report(by Registered Fire
Consultant)
AHJ (Civil Defence) -No Objection
Certificate (NOC)
Periodic façadeinspections (byRegistered Fire
Consultant)
AHJ (Civil Defence)final inspection &
final NOCBuilding permit
![Page 6: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/6.jpg)
UAE – Key technical requirements1) Reaction to fire testEach component of thefaçade to be fire tested(exposed, withoutskin)
2) Full-scale assembly testFaçade system to be firetested
3) Perimeter fire barrierCertified and listed systemto be provided at slab edge
4) Cavity fire barrierProvided at each floor level& around façade openings
![Page 7: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/7.jpg)
UAE – Key administrative requirements
Local Civil Defence approved &certified:1. Façade contractor2. Façade supplier/fabricator3. Façade system
Fire consultant/engineer:• Approved House of Expertise by
Civil Defence• Accredited to ISO 17020 or IAS
AC291• Min. 5 years experience in
façade systems• Ongoing training and
certification
![Page 8: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/8.jpg)
UAE – Façade Fire Assessment Report
ReviewDocumentation
Approved FireStrategy
FaçadeWorkshop
Documentation
Materialsubmittals
Draft ReportCivil Defenceregistration &
COC
Undertakingletters
EngineeringJudgements (EJ)
Final Report Civil Defence(AHJ) submission
Civil Defence(AHJ) NOC
![Page 9: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/9.jpg)
UAE – Façade Inspections
20%
40%
60%
80%
100%• Frequency:
• Facade & cavity fire barriers: at leastevery 20% intervals of the totalbuilding height
• Perimeter fire barriers: 1 destructivetest every 152 linear meter (500 ft) asper ASTM E2393
• Verify installation: as per Façade FireAssessment Report
• Third party inspection accreditation:ISO 17020 & IAS AC291
![Page 10: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/10.jpg)
Building Compliance Pathways - Australia
Building Code of Australia (BCA)
Performance Requirements
Performance SolutionDeemed to Satisfy Solution
Prescriptive Performance Based
and / or
![Page 11: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/11.jpg)
• BCA C1.9 – Non-Combustible Construction• BCA C1.14 – Ancillary Elements• BCA C2.6 – Vertical or Horizontal Spandrels• BCA C3.16 – Construction Joints
External Fire Spread under the BCA
![Page 12: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/12.jpg)
BCA C1.9 Non-Com
bustible
Material Concessions
Entire Wall Non-combustible
Bonded Laminates
![Page 13: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/13.jpg)
BCA C1.14 Ancillary Elements
![Page 14: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/14.jpg)
BCA C2.6 – Spandrel Separation
Vertical Spandrel Horizontal Spandrel Glass Curtain Wall
![Page 15: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/15.jpg)
BCA Verification Method CV3
Fire Test
Sprinkler
Spandrels
Cavity Barriers
![Page 16: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/16.jpg)
Guidelines – Existing & New buildings• IEAust Society of Fire Safety (SFS)• Queensland• Fire & Rescue NSW• Victoria• WA
![Page 17: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/17.jpg)
BCA ACPAssessmentMethodology
![Page 18: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/18.jpg)
Advantages
United Arab Emirates• Provides a minimum benchmark
for prescriptive compliance• Simple to apply, review and
approve• Consistent approach and
conclusions• Design review to site verification• Company & system registration
mandatory
Australia• Prescriptive and Performance
Options• Verification method and
Performance approach allowholistic approach and tailoring tobuildings fire strategy
• Mechanism to assess existingbuildings and new/innovativematerials
• Linked to the building firestrategy
![Page 19: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/19.jpg)
Way Forward – Key Recommendations
• Difference between approach – same as any other prescriptive vsperformance-based design methodology
• Prescriptive design (as per UAE approach) to be considered theminimum benchmark + performance-based design (as per Australianapproach) applied to demonstrate compliance
• Onsite verification to be mandatory (as per UAE approach) includingISO 17020 accreditation and third-party inspection of perimeter firebarriers (as per ASTM E2393)
• Minimum qualification of fire engineer (PE, CPEng, etc.) with relevantfaçade expertise (additional education on external fire spread req’d)
![Page 20: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/20.jpg)
Recap
• Background• Prescriptive compliance – United Arab Emirates (UAE)• Prescriptive & performance-based compliance – Australia• Summary & key recommendations• Questions
![Page 21: A comparison of regulatory compliance approaches to façade ...€¦ · 1) Reaction to fire test Each component of the façade to be fire tested (exposed, without skin) 2) Full-scale](https://reader031.vdocuments.us/reader031/viewer/2022011919/601098cb86480e19922e6da1/html5/thumbnails/21.jpg)
Kia Mihi (Thank You)
• Mr Faimeen Shah
Ø www.vortexfec.com
• Dr Amer Magrabi