a better way to treat water · water problems and notes. cascadian ics solution spots white spots...

38
A Better Way to Treat Water ·Easy ·Effective ·Economical ·Eco-Friendly

Upload: others

Post on 08-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

A Better Way to Treat Water

·Easy ·Effective ·Economical ·Eco-Friendly

Page 2: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Do You Need Water Treatment?

Page 3: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

What Problems are You Experiencing?Water Problems and Notes. Cascadian ICS Solution

Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after water evaporates.

High Hardness Water.

Build-up White - grey hard scale build-up on faucets, spray nozzles, dish washers etc.

High Hardness Water.

Red, orange, brown or black stains on clothes, dishes, toilets, sinks, tubs showers, patio's, sidewalks etc.

Clear Iron and/or Manganese. Water is drawn clear from tap but turns red, orange, brown or black color after sitting.

Blue stains in sinks, tubs, showers etc. Copper in water. Copper in water occurs naturally and it can be caused by low pH water dissolving copper pipe and fittings potentially leading to failure.

Spots that won't come clean

White / grey spots that have etched (can't be removed from) glasses, dishes, shower doors, windows etc.

Silica. Often mistaken for hardness but treatment for hardness does not work.

Chlorine taste and odor Chlorine. Used for disinfection.

Bad taste and odor (Not rotten egg odor)Metallic taste / Odor

Odors Rotten egg odor H2S (Hydrogen Sulfide) ICS-H

Sediment or other particles that are visible when drawn from tap and settle out within 1 hour.

Sediment and particles.

Red, orange, brown or black colored particles in water when first drawn from tap.

Oxidized Iron. Colored when drawn from tap.

Odors

Taste & Odor

Any ICS product with a "P" in the part number

Any ICS product with a "S" in the part number

Any ICS product with a "T" in the part number

Soap Problems

Colored Stains

High Hardness Water.Using lots of soap in laundry.Whites are grey and colors are dingy.Soap scum build-up in tubs, sinks and showers.Laundry, hair, dishes etc. don't rinse clean.

Sediment

Part Numbers: P = PolyHalt® for Hardness, iron sequestration, low pH and silica; S = Sediment Filter; T = Chlorine Taste and Odor; H = Hydrogen Sulfide (H2S Rotten Egg) Odor; CT = Commercial

Page 4: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Is your water Hard?

Soap Doesn’t Form Suds (P)

Bad Hair (P)

Hard Scale Buildup (P)

Hard Scale Buildup (P)

Grey Whites and Dingy Colors (P)

White Spots (P)

Soap Scum or Rings in Tubs, Showers, Sinks or Toilets (P)

Expensive Appliance Repairs (P)

Hard Scale Buildup (P)

Clothes Washer Stained and Damaged (P)

Embarrassing Water Spots

Page 5: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Do You Have Staining Problems?

Orange, Red, Brown or Black Staining (S, P, I)

Orange, Red, Brown or Black Staining (S, P, I)

Blue / Green Stains (S, P, I)

Orange, Red, Brown or Black Staining (S, P, I)

Staining in Toilets (S, P, I)

Iron Build-Up in Dishwasher (S, P, I)

Page 6: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Do You Have These Problems?

Silica Etching and PittingWon’t Come Clean (P)

Hydrogen Sulfide (rotten egg) Odor (H)Pin Hole Leaks (P) Sediment or Cloudy Water (S)

Chlorine Taste and Odor (T)

Slippery Slimy Feeling, Don’t Feel Like Soap Rinses Off (P)

Can’t Water Plants with Salt Softened Water (P)

Loud salt-based softeners and filters

keeping you awake at night (All ICS)

Page 7: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Problem and Solutions Matrix

Part Numbers: P = PolyHalt® for Hardness, iron sequestration, low pH and silica; S = Sediment Filter; T = Chlorine Taste and Odor; H = Hydrogen Sulfide (H2S Rotten Egg) Odor; CT = Commercial

POE (Point of Entry)

CT(Commercial Treatment)

POU (Point of Use)

SP

TP

STP

H P S5

SPU

TPU

CTP

35 C

TS05

M C

TTO

Chlorine Bad Taste and Odor X X X X

Hardness / Mineral Deposits X X X X X X X

Hydrogen Sulfide – H2S Rotten Egg Odor X

Iron – Clear – Red / Orange Staining X X X X X X X

Iron – Colored - Red / Orange Staining X X X X X

Manganese – Clear - Black / Brown Staining X X X X X X X

Manganese – Colored - Black / Brown Staining X X X X X

pH (low) X X X X X X X

Sediment X X X X X

Silica – Corrosion, Etching and Pitting X X X X X X X

Best Treatment GPM Flow 4 4 4 3 4 NA 1 1 10 NA 8

Peak GPM Flow 15 15 15 8 15 15 5 3 35 100 15

1. Locate water problem in left column2. Find solution to the right3. See CascadianWater.com for details

Page 8: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Source

Irrigation

POE (Point of Entry)Treats all water prior

to entering house

Notes: It is safe to water plants, lawns and gardens with PolyHalt® softened waterPOU (Point of Use) treatment is at the location needed such as

• Kitchen sink• Laundry• Ice maker

Where does my treatment go?

Page 9: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Manufactured since 2011 ICS is the Next Generation in water treatment.

ICS Advantages Include:• Eco-friendly – No salt and no salty wastewater, can be used where salt-based

softeners are banned. Save 30± bags of salt and 1,000’s of gallons of water every year

• Budget Friendly – Lower cost to buy, install and maintain • Smaller – size, lower cost and hangs on wall saving floor space• Simpler – quick and easy to install and simple 5 minutes to maintain on average• No Electricity Required – No power problems, no computer programming or

adjustments required• No Drain Required – No salty waste water added to septic or sewer systems• Silent Operation – No moving parts, nothing to break down, no control noise and

no noisy water flowing to drain• No Slippery Feeling – Does not make you feel slippery or slimy when rinsing soap• 3rd Party Certified – Independently certified safe for drinking water treatment • Wide Range of Sizes – Typical systems treat POU and POE applications and larger

systems are available to treat up to 180 gpm each for commercial and industrial applications.

What is ICS (Integrated Cartridge Solutions)?

Page 10: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Luminor Ultraviolet Disinfection SystemsPerfect for well water or anywhere for protection against bacteria

Required Pre-Treatment: 5 micron sediment filter.

All ICS systems with an “S” in the part number meet requirement.

LB5-

061

LB5-

101

LB5-

151

LB52

01

6 gpm X10 gpm X15 gpm X20 gpm X

Flow Rate:

Model: UV Product LinksLB5-061

LB5-101

LB5-151

LB5-201

Manual for all Models

Page 11: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

What is PolyHalt®?

Page 12: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

What is PolyHalt®?• PolyHalt® is a different way to treat water using ion bond technology • It is core to the ICS line of treatment solutionsProblems Treated with PolyHalt® Include:• Hardness• Clear iron and manganese stains• Red, orange, black and brown• Low pH – Blue / Green Stains

• Corrosive conditions• Scale buildup in hot water systems• Silica deposits – etching and pitting

PolyHalt® is Certified Safe• PolyHalt® is derived from naturally occurring phosphorus bearing rock

an essential element for life• PolyHalt® is independently certified by NSF for use in water treatment

Page 13: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

What to Expect with PolyHalt®

• Just like conventional salt-based softeners, if water is not wiped up there will be spots but any spots will be easier to clean

• PolyHalt® softened water will not feel slippery or slimy

• Hardness test results will be equal pre & post treatment

• Water could be worse temporarily while plumbing is being cleaned. Be sure to flush hot water tanks. May need to clean aerators, showerheads etc.

• Your satisfaction is guaranteed, see End User Agreement for details

Page 14: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

PolyHalt® Ion Bond TechnologyA powerful chemical bond is formed between oppositely charged ions to form a new complex preventing problems

Ion 2 PolyHalt®

PHT

Ion 1 Hardness

Hd

Hd PHT

• Bonded ions form a new complex

• Problems are solved• Water is soft, iron

doesn’t stain etc.

Page 15: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

What Makes PolyHalt® Better?

Page 16: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Overview Comparison to Salt-Based SoftenersParameter CASCADIAN® ICS Salt-Based SoftenerCost Hundreds Thousands

Maintenance Cartridge Kit, <15 min./Year

Salt, System Maintenance≈ 20 Hours/Year

Physical Size < Two feet on wall ≈ 4 feet x 2 feet on ground and 5 or more feet tall

Drain None Required

Power None Required

Installation time ≈ 1 hour ≈ 4+ hours

Moving Parts to Wear None Too many to count

Noise Silent Very noisy when regenerating

Water Wasted None ≈ 10,000 gallons / year (10” 48k systems, weekly regen.)

Salt Used / Year None ≈ 1,170 pounds ≈ 30 bags / year

Slippery / Slimy Feeling?

No Yes

Sediment and Chlorine Filters Included?

Yes No

Page 17: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Compare Annual Operating Costs

1ICS-SPK

ICS-SPIon Bond Softenerwith Sediment Filter

10,000 Gallons

Waste Water1

SedimentFilter

10,000 gallons fresh water

30bags of

salt

Ion ExchangeSalt-Based Softenerwith Sediment Filter

$220 / year$18 / month

$315 - $465 / year$26 - $39 / month

5 - 15Minutes

/ Year

Time toMaintain

12 -24 Hours/ Year

Time toMaintain

Page 18: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Sediment

16”

Carbon

16”

Iron

16”

Sediment

9”

Silica Filter

32”

Salt BasedSoftener

32”

pH Filter

16”

Over 12 Feet Long x 5.5 Feet Tall x 2 Feet DeepSits on floor

16” Long x 30” Tall x 8” Deep

Hangs on wall

Compare Physical Size

16”

ICS-STP

OR

Note: The ICS-STP does the work of all these traditional treatment systems

Page 19: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Soap Scum StubbornHard Water Spots

Stains

PolyHalt® fixes these water quality problems

Page 20: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

PolyHalt® fixes these salt problems

High AnnualMaintenance

Buying, Transporting,Storing andLifting Salt

Dealing WithMessy Salt Bags

Page 21: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

PolyHalt® easily fixes these location problems

No DrainAvailable

No SpaceAvailable

No PowerAvailable

Page 22: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

PolyHalt® fixes these regulatory problems

Salt BasedSoftener Bans

No Wasted Water

NoAdded Salt

Page 23: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

PolyHalt® makes life better

No salt or wastewater added to

our environment

Protect ourenvironment

Don’t buy, lift,transport, use,

or clean up

No salt todeal with

Lower cost treatment,less time and money

cleaning your home, ormaintaining/replacing appliances

Save timeand money

Spend time andmoney doing moreof what you want

Page 24: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Technical Details

Page 25: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Minimum flow rates (GPM) for homes based on number of bedrooms and bathrooms.

# bedroomsin home

# of bathrooms in home

1 1.5 2 3

2 6 GPM 8 GPM 10 GPM

3 8 GPM 10 GPM 12 GPM

4 10 GPM 12 GPM 14 GPM 16 GPM

5 13 GPM 15 GPM 17 GPM

6 16 GPM 18 GPM

(From Private Water Systems Handbook, 1992.)

How much water do I need to treat?

Page 26: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

PolyHalt®

• Treatment for Hardness + iron, low pH, silica

• Does not lower pH or dissolve plumbing or appliances

• Permanent fix is stable over distance and time

• Safe for all plumbing and appliances

• Available with sediment and chlorine filters in a single housing

• Available with sediment and chlorine filters in a dual housing

• Filters last ≈ 12 months

NuvoH2O• Treatment for Hardness only

• Lowers pH (creates acid water). Acid water dissolves plumbing and appliances

• Loses effectiveness over distance and time

• Available with chlorine filter only in a dual housing

• Filters last ≈ 6 months

Compare PolyHalt® to NuvoH2O

Page 27: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Cascad

ian W

ater 530

1 Airp

ort Rd

. Cle E

lum

, WA

. 98922 •P

hon

e 509-674

-40

00

•Fax 509-674

-40

02 •C

ascadian

Water.com

“Life’s Sho

rt – En

joy Y

ou

r Water

™”

Upgrade Existing N

uvoH2O

Systems w

ith CASCADIAN® Filters

Treat More Problem

s and Last Twice as Long

For those w

ith N

uvo system

s we offer th

e opp

ortun

ity for imp

rovemen

t by sw

itchin

g to C

ascadian

® IC

S-SP

or ICS-TP

series replacem

ent filters. Fit N

uvo h

ousin

gs p

erfectly, noth

ing

to chan

ge b

ut th

e cartridg

e.

ICS rep

lacemen

t filters are differen

t from N

uvo; th

ey last twice as lon

g an

d g

et more d

one in

a sing

le cartrid

ge. W

ith th

e develop

men

t of our exclu

sive PolyC

or™ Tech

nolog

y we com

bin

e all the b

enefits of

PolyH

alt® w

ith oth

er specialized

filters to add

ress more p

roblem

s in a sin

gle h

ousin

g. IC

S cartridg

es with

P

olyHalt®

offer filtration an

d taste an

d od

or imp

rovemen

t wh

ere Nu

vo does n

ot, they d

o not low

er the p

H

like Nu

vo and

go even

furth

er by p

rotecting

again

st low p

H an

d corrosive con

dition

s all wh

ile lasting

twice

as long .

ICS filters w

ith P

olyHalt

® outp

erform N

uvo:

ICS-SP

Series Treats IC

S-TP Treats

Nu

vo Treats: H

ardn

ess

H

ardn

ess

Hard

ness

Existin

g scale

E

xisting

Scale E

xisting

scale Iron

Iron

Man

gan

ese

M

ang

anese

Silica

Silica Low

pH

Low

pH

C

orrosive cond

itions

Corrosive con

dition

s Sed

imen

t

Taste &

Od

or

Do you

r Nu

voH2O

custom

ers a favor: O

ffer CA

SCA

DIA

N® rep

lacemen

t filters that last tw

ice as long

, treat m

ore prob

lems an

d fit N

uvoH

2O h

ousin

gs p

erfectly.

See the com

parison

table on

the b

ack for the com

plete list of b

enefits for each

prod

uct.

Please con

tact us w

ith q

uestion

s or visit ww

w.C

ascadian

Water.com

for prod

uct d

etails.

Nu

vo Hom

e R

eplacem

ent

ICS-SP

122K

Nu

vo Man

or R

eplacem

ent

ICS-SP

1242K

or IC

S-TPK

Nu

vo Stud

io R

eplacem

ent

ICS-SP

0621K

PolyCor ™ Eco-friendly

Technology

Page 28: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Cascad

ian W

ater 530

1 Airp

ort Rd

. Cle E

lum

, WA

. 98922 •P

hon

e 509-674

-40

00

•Fax 509-674

-40

02 •C

ascadian

Water.com

“Life’s Sho

rt – En

joy Y

ou

r Water

™”

Compare CASCADIAN

® ICS-SP and ICS-TP Series to NuvoH

20

Feature:

CA

SCA

DIA

ICS-SP

Series R

eplaces M

anor,

Hom

e or Stud

io

CA

SCA

DIA

ICS-TP

R

eplaces M

anor

Ad

ds Taste &

O

dor

Nu

voH2O

Stu

dio,

Hom

e or M

anor

7

Recom

men

ded

Frequ

ency of C

artridg

e Ch

ang

es 1 Y

ear 1 Y

ear 6 M

onth

s

Com

es with

a bottom

drain

for safe and

easy cartridg

e chan

gin

g

Works at p

H less th

an 7.0

Treats Clear or Solu

ble Iron

and

Man

gan

ese1

Treats Low p

H con

dition

s2

Treats Silica etchin

g an

d p

itting

3

Treats Ag

gressive / C

orrosive Water C

ond

itions

4

Protects P

lum

bin

g, Fixtu

res and

Ap

plian

ces5

Filters Sedim

ent d

own

to 5 micron

Filters Colored

Iron an

d M

ang

anese

Treats Taste and

Od

or Prob

lems In

clud

ing

Ch

lorine

6

Can

test water to d

etermin

e wh

en it’s tim

e to chan

ge filter

Treatmen

t stable over tim

e and

distan

ce

Availab

le throu

gh

nation

al retail hard

ware ch

ain (as of M

arch 20

15)

Certified

for use in

drin

king

water

Plu

mb

ing

Pip

e Size 1"

1" 1"

Max Flow

Ratin

g - G

PM

15

15 15 - 18

Easy W

all Mou

nt In

stallation

Op

erates with

out Salt, P

ower or D

rain Lin

e

Salt Free Hard

ness Treatm

ent

No “Slim

y / Slipp

ery” Feeling

Can

redu

ce existing

min

eral dep

osits in p

lum

bin

g

To learn ab

out all IC

S prod

ucts w

ith featu

res, capab

ilities and

operatin

g con

dition

s visit Cascad

ianW

ater.com

1 Clear or solu

ble iron

and

man

gan

ese (draw

n clear th

en tu

rns color w

ith tim

e) - stains fixtu

res, clothin

g etc.

2 Low p

H soften

s and

dissolves m

etallic comp

onen

ts of plu

mb

ing

causin

g p

roblem

s such

as “blu

e” stainin

g an

d

“pin

hole” leaks in

copp

er pip

ing

. 3 E

tchin

g an

d p

itting

of glass an

d fixtu

res, can cau

se stainin

g p

roblem

s and

a glassy like b

uild

up

. 4 A

gg

ressive / corrosive cond

itions su

ch as low

Total Dissolved

Solids – E

ats away at m

etallic comp

onen

ts. 5 P

olyHalt ® w

ill insu

late metallic su

rfaces from low

pH

, agg

ressive or corrosive waters.

6 Not m

eant for h

ydrog

en su

lfide (Su

lfur or “R

otten E

gg

”) odor.

7 Inform

ation ab

out N

uvoH

2O p

rodu

cts from N

uvoH

2O an

d oth

er pu

blicly availab

le sources.

PolyH

alt®

is NSF C

ertified for d

rinkin

g w

ater

Man

or R

eplacem

ent

ICS-SP

1242K

or IC

S-TPK

Hom

e R

eplacem

ent

ICS-SP

122K

Stud

io R

eplacem

ent

ICS-SP

0621K

Page 29: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

End User Agreement

Page 30: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Cascadian Water

5301 Airport Rd. Cle Elum, W

A. 98922 •Phone 509-674-4000 •Fax 509-674-4002 •w

ww

.CascadianWater.com

“Life’s Sho

rt – Enjo

y Yo

ur W

ater™”

End

User A

greem

ent

Con

gratu

lations on

your p

urch

ase of the sim

plest, sm

allest, lowest cost, m

ost eco-friend

ly an

d su

ccessful w

ater treatmen

t solution

available.

The p

urp

ose of this d

ocum

ent is to h

elp u

s ensu

re you h

ave been

mad

e aware of im

portan

t d

etails abou

t your n

ew w

ater treatmen

t system th

at help

ensu

re our cu

stomers are 10

0%

satisfied.

We m

ake every effort to provid

e wh

at may very w

ell be th

e most su

ccessful w

ater treatmen

t system

s available an

ywh

ere. We b

elieve you d

eserve to enjoy th

e best w

ater possib

le in you

r hom

e or b

usin

ess. How

ever, no w

ater treatmen

t system can

treat all water p

roblem

s in 10

0%

of ap

plication

s. If you’re n

ot gettin

g th

e results you

expect, ou

r experts m

ay be ab

le to help

.

Before you

pu

rchase you

r Cascad

ian W

ater treatmen

t system, w

e wan

t you to kn

ow som

e im

portan

t inform

ation reg

ardin

g w

ater, water treatm

ent an

d C

ascadian

Water treatm

ent p

rodu

cts.

• It is our g

oal for you to b

e able to en

joy your w

ater once treated

with

our p

rodu

cts.

• We su

gg

est you test you

r water to g

et a better id

ea of exactly wh

at need

s to be treated

. You m

ay b

e able to g

et a water q

uality rep

ort from you

r water com

pan

y and

we can

often u

se that

inform

ation to recom

men

d treatm

ent p

rodu

cts. We are h

app

y to use resu

lts from a certified

lab

to make treatm

ent recom

men

dation

s.

• We recom

men

d you

r water treatm

ent system

be in

stalled b

y an exp

erience w

ater treatmen

t p

rofessional or p

lum

ber w

ith exp

erience.

• Treating

your w

ater does n

ot mean

your w

ater will b

e 100

% p

erfect. If you are n

ot hap

py w

ith you

r treated

water ad

dition

al testing

and

treatmen

t may b

e requ

ired. W

ater qu

ality often ch

ang

es over tim

e and

from season

to season. A

dd

itional treatm

ent m

ay be req

uired

.

• We w

ant you

to get th

e righ

t treatmen

t. For every water treatm

ent system

and

replacem

ent

cartridg

e kit we p

rovide sp

ecific Prod

uct D

etails and

Con

dition

s for Op

eration. R

eadin

g an

d

un

derstan

din

g th

ese Prod

uct D

etails and

Con

dition

s for Op

eration is very im

portan

t as installin

g

a Cascad

ian W

ater system or R

eplacem

ent C

artridg

e Kit w

here C

ond

itions for O

peration

are not

met m

ay redu

ce prod

uct effectiven

ess and

/ or lead to m

ore frequ

ent cartrid

ge filter ch

ang

es. You

have read

, un

derstan

d an

d accep

t these P

rodu

ct Details an

d C

ond

itions for O

peration

.

After C

ascadian

Water treatm

ent system

is installed

:

• Your w

ater may b

e worse w

hile you

r plu

mb

ing

is bein

g clean

ed. Th

is is a temp

orary prob

lem an

d

shou

ld resolve itself w

ithin

30-60

days.

• It is recomm

end

ed all h

ot water tan

ks be d

rained

and

flush

ed at th

e time of in

stallation to red

uce

the tim

e requ

ired for you

to beg

in en

joying

your w

ater.

• You w

ill still need

to clean you

r hom

e or bu

siness. If rem

oving

chlorin

e you m

ay have to clean

ap

plian

ces such

as toilets more often

.

• Hard

ness w

ill measu

re the sam

e before an

d after treatm

ent w

ith P

olyHalt

® ion b

ond

salt free soften

ers. This is b

ecause P

olyHalt

® ion b

ond

softeners an

d filters d

o not rem

ove hard

ness

min

erals. PolyH

alt® sim

ply ch

ang

es the w

ay hard

ness m

inerals b

ehave cau

sing

the w

ater to be

soft. Treated h

ardn

ess min

erals remain

in th

e water an

d sim

ply p

ass throu

gh

with

out cau

sing

p

roblem

s.

Page 31: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Cascadian Water

5301 Airport Rd. Cle Elum, W

A. 98922 •Phone 509-674-4000 •Fax 509-674-4002 •w

ww

.CascadianWater.com

“Life’s Sho

rt – Enjo

y Yo

ur W

ater™”

• pH

will m

easure th

e same b

efore and

after treatmen

t. PolyH

alt® treatm

ent d

oes not ad

d

hard

ness m

inerals to you

r water to ad

just p

H as d

oes an au

tomatic treatm

ent system

. PolyH

alt®

works b

y add

ing

a very thin

protective coatin

g to m

etallic surfaces in

the p

ipin

g system

. This

coating

help

s protect m

etallic surfaces from

corrosive cond

itions of low

pH

water.

• PolyH

alt® ion

bon

d soften

ers do n

ot make th

e water feel “slip

pery” or “slim

y”.

• Your treatm

ent system

requ

ires period

ic replacem

ent of cartrid

ges, O

-ring

s, etc. An

nu

al rep

lacemen

t of your C

ascadian

Water cartrid

ge filter is recom

men

ded

. How

ever, water q

uality

and

volum

e may req

uire m

ore frequ

ent rep

lacemen

t.

• Most filters w

ill last an en

tire year. Water q

uality an

d volu

me u

sed m

ay cause m

ore frequ

ent

replacem

ent.

Satisfaction G

uaran

tee

We’re so con

fiden

t in th

e perform

ance of C

ascadian

Salt free water soften

er and

filter systems th

at if you

are not com

pletely satisfied

with

in th

e first 60 d

ays from th

e date you

bou

gh

t it, you m

ay retu

rn it for a fu

ll refun

d of you

r pu

rchase p

rice, less ship

pin

g an

d h

and

ling

. Everyon

e’s water is

differen

t. If you’re n

ot gettin

g th

e results you

expect g

ive our exp

erts a chan

ce to help

.

Notes:

o Cu

stomer satisfaction

prog

ram ap

plies to treatm

ent system

s only. R

eplacem

ent filter kits are

not covered

.

o Systems in

stalled w

here con

dition

s for operation

are not m

et do n

ot qu

alify for Satisfaction

Gu

arantee.

o On

ly systems th

at have b

een p

urch

ased d

irectly from C

ascadian

throu

gh

Cascad

ian’s w

ebsite

can b

e return

ed to C

ascadian

. Systems p

urch

ased th

roug

h oth

er retailers, affiliates or installers

mu

st be retu

rned

in accord

ance w

ith th

eir respective retu

rns an

d refu

nd

s policy.

o Cascad

ian treatm

ent system

s may also b

e covered b

y a man

ufactu

rer’s warran

ty. Please refer to

the w

arranty d

ocum

entation

inclu

ded

with

your p

rodu

ct or on th

e Cascad

ian w

eb site for m

ore in

formation

.

o Systems p

urch

ased w

ithou

t sign

ing

this d

ocum

ent d

o not q

ualify for Satisfaction

Gu

arantee.

I have read

, un

derstan

d an

d accep

t this ag

reemen

t.

By _______________________________________, E

mail _______________________________

Ad

dress ________________________________________________________________________________________

Sign

ature _____________________________, D

ate ___/____/_______, ICS Item

Nu

mb

er ICS-____________

Sold b

y (Nam

e) _____________________________, Em

ail _______________________, Ph

one ______________

Com

pan

y _____________________________________________, Co. P

hon

e ______________________________

Please keep

a copy of th

is agreem

ent for you

r records.

We look forw

ard to h

earing

and

sharin

g you

r person

al water treatm

ent su

ccess story.

Page 32: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

Specifications forSelect Systems

See cascadianwater.com for all system specifications

Page 33: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

   

 

O3 W

ater System

s, Inc. D

BA

– Cascad

ian W

ater 530

1 Airp

ort R

d. C

le Elu

m, W

A. 98

922 P

ho

ne 50

9-674-4

00

0 F

ax 509-674

-40

02 w

ww

.Cascad

ianW

ater.com

“Life’s Sh

ort – En

joy Yo

ur W

ater™”

CA

SC

AD

IAN

® ICS

-SP

Sp

ecifica

tion

s an

d O

pe

ratin

g C

on

ditio

ns:

Item N

um

ber

Raw

Water P

aramete

r C

on

ditio

n fo

r Op

eration

D

etails

ICS

-SP

(S

edim

ent /

Po

lyHalt

®)

Bacteria

Ch

lorin

e C

ollo

idal Iro

n

Hard

ness

Hyd

rocarb

on

s, oils, o

r lub

ricants

Hyd

rog

en S

ulfid

e Iro

n &

Man

gan

ese (Clear O

nly)

Iron

& M

ang

anese (C

olo

red)

Iron

Bacte

ria O

rgan

ic Iron

p

H

Sed

imen

t S

ilica Tan

nin

/ Org

anics

Turb

idity

No

ne A

llow

ed

N

A

NA

M

ax 25 grain

s (427 p

pm

) N

on

e Allo

we

d

No

ne A

llow

ed

<6 p

pm

Co

mb

ined

N

A

No

ne A

llow

ed

No

ne A

llow

ed

>6.0

and

<8.5

>5 micro

n

<100

pp

m

No

ne A

llow

ed

< 1 N

TU

Dim

ensio

ns

Co

nn

ection

M

ax Cap

acity B

est Treatmen

t Flo

w

Max F

low

M

ax Pressu

re

Min

Temp

erature

Max Tem

peratu

re N

o. o

f Filters

7.5" x 8.5" x 29.5"

1” 12 m

on

ths

4-8

gp

m

15 gp

m

120 p

si 39

.2° F

113° F

1

Ge

ne

ral a

nd

Co

mm

on

Info

rma

tion

for a

ll ICS

Syste

ms:

If R

aw W

ater Param

eter Co

nd

ition

for O

peratio

n = “N

A” th

e systems w

ill no

t affect and

is no

t affected b

y con

centratio

ns o

f th

at param

eter typically fo

un

d in

drin

king

water

If R

aw W

ater Param

eter - C

on

ditio

n fo

r Op

eration

= “No

ne A

llow

ed” R

emo

ve thro

ug

h ad

equ

ate pre-treatm

en

t

If Raw

Water P

aramete

r - Co

nd

ition

for O

peratio

n = “N

ot fo

r extreme levels” Th

e cartridg

e usefu

l life may b

e sho

rtened

and

req

uire m

ore freq

uen

t rep

lacem

ent.

W

ater con

ditio

ns o

utsid

e of th

e abo

ve specified

limits m

ay lead to

a sho

rtened

filter life.

All stated

flow

rates are inte

rmitten

t flow

s. Co

nstan

t flow

s may affect resu

lts.

Extrem

e levels of an

y param

eter may sh

orte

n u

seful cartrid

ge life

Stated

“Max C

apacity” is ju

st that, it is th

e maxim

um

capacity o

f the filte

r. Yo

ur w

ater che

mistry m

ay redu

ce Max C

apacity

and

mo

re freq

uen

t filter rep

lacemen

t may b

e requ

ired

Iro

n an

d m

ang

anese treatm

en

t do

es no

t inclu

de iro

n in

the

follo

win

g fo

rms:

o Co

lloid

al (sub

micro

n sized

iron

particles)

o Org

anically B

ou

nd

(iron

that is b

ou

nd

to an

org

anic su

bstan

ce such

as tann

ins)

Typically, th

e presen

ce of co

lloid

al and

org

anic iro

n an

d m

ang

anese is d

eterm

ine

d afte

r the u

sual treatm

ents fo

r iron

and

m

ang

anese are in

ade

qu

ate or fail. Th

ere are sp

ecialty treatmen

ts for iro

n an

d m

ang

anese in

the co

lloid

al and

org

anic fo

rms.

Please co

ntact u

s for assistan

ce.

WA

RN

ING

: D

o n

ot u

se with

water th

at is micro

bio

log

ically un

safe or o

f un

kno

wn

qu

ality with

ou

t ade

qu

ate disin

fection

befo

re or after

un

it.

Page 34: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

   

 

O3 W

ater System

s, Inc. D

BA

– Cascad

ian W

ater 530

1 Airp

ort R

d. C

le Elu

m, W

A. 98

922 P

ho

ne 50

9-674-4

00

0 F

ax 509-674

-40

02 w

ww

.Cascad

ianW

ater.com

“Life’s Sh

ort – En

joy Yo

ur W

ater™”

CA

SC

AD

IAN

® ICS

-TP

Sp

ecifica

tion

s an

d O

pe

ratin

g C

on

ditio

ns:

Item N

um

ber

Raw

Water P

aramete

r C

on

ditio

n fo

r Op

eration

D

etails

ICS

-TP

(Taste &

Od

or /

Po

lyHalt

®)

Bacteria

Ch

lorin

e C

ollo

idal Iro

n

Hard

ness

Hyd

rocarb

on

s, oils, o

r lub

ricants

Hyd

rog

en S

ulfid

e Iro

n &

Man

gan

ese (Clear O

nly)

Iron

& M

ang

anese (C

olo

red)

Iron

Bacte

ria O

rgan

ic Iron

p

H

Sed

imen

t S

ilica Tan

nin

/ Org

anics

Turb

idity

No

ne A

llow

ed

<3 p

pm

N

A

Max 25 g

rains (4

27 pp

m)

No

ne A

llow

ed

N

on

e Allo

we

d

<6 pp

m C

om

bin

ed

<0.3 p

pm

N

on

e Allo

we

d

No

ne A

llow

ed

>6

.0 an

d <8

.5 >5 m

icron

<10

0 p

pm

N

on

e Allo

we

d

< 1 NTU

Dim

ensio

ns

Co

nn

ection

M

ax Cap

acity B

est Treatmen

t Flo

w

Max F

low

M

ax Pressu

re

Min

Temp

erature

Max Tem

peratu

re N

o. o

f Filters

7.5" x 8.5" x 29.5"

1” 12 m

on

ths

4-8

gp

m

15 gp

m

120 p

si 39

.2° F

113° F

1

Ge

ne

ral a

nd

Co

mm

on

Info

rma

tion

for a

ll ICS

Syste

ms:

If R

aw W

ater Param

eter Co

nd

ition

for O

peratio

n = “N

A” th

e systems w

ill no

t affect and

is no

t affected b

y con

centratio

ns o

f th

at param

eter typically fo

un

d in

drin

king

water

If R

aw W

ater Param

eter - C

on

ditio

n fo

r Op

eration

= “No

ne A

llow

ed” R

emo

ve thro

ug

h ad

equ

ate pre-treatm

en

t

If Raw

Water P

aramete

r - Co

nd

ition

for O

peratio

n = “N

ot fo

r extreme levels” Th

e cartridg

e usefu

l life may b

e sho

rtened

and

req

uire m

ore freq

uen

t rep

lacem

ent.

W

ater con

ditio

ns o

utsid

e of th

e abo

ve specified

limits m

ay lead to

a sho

rtened

filter life.

All stated

flow

rates are inte

rmitten

t flow

s. Co

nstan

t flow

s may affect resu

lts.

Extrem

e levels of an

y param

eter may sh

orte

n u

seful cartrid

ge life

Stated

“Max C

apacity” is ju

st that, it is th

e maxim

um

capacity o

f the filte

r. Yo

ur w

ater che

mistry m

ay redu

ce Max C

apacity

and

mo

re freq

uen

t filter rep

lacemen

t may b

e requ

ired

Iro

n an

d m

ang

anese treatm

en

t do

es no

t inclu

de iro

n in

the

follo

win

g fo

rms:

o Co

lloid

al (sub

micro

n sized

iron

particles)

o Org

anically B

ou

nd

(iron

that is b

ou

nd

to an

org

anic su

bstan

ce such

as tann

ins)

Typically, th

e presen

ce of co

lloid

al and

org

anic iro

n an

d m

ang

anese is d

eterm

ine

d afte

r the u

sual treatm

ents fo

r iron

and

m

ang

anese are in

ade

qu

ate or fail. Th

ere are sp

ecialty treatmen

ts for iro

n an

d m

ang

anese in

the co

lloid

al and

org

anic fo

rms.

Please co

ntact u

s for assistan

ce.

WA

RN

ING

: D

o n

ot u

se with

water th

at is micro

bio

log

ically un

safe or o

f un

kno

wn

qu

ality with

ou

t ade

qu

ate disin

fection

befo

re or after

un

it.

Page 35: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

   

 

O3 W

ater System

s, Inc. D

BA

– Cascad

ian W

ater 530

1 Airp

ort R

d. C

le Elu

m, W

A. 98

922 P

ho

ne 50

9-674-4

00

0 F

ax 509-674

-40

02 w

ww

.Cascad

ianW

ater.com

“Life’s Sh

ort – En

joy Yo

ur W

ater™”

CA

SC

AD

IAN

® ICS

-ST

P S

pe

cificatio

ns a

nd

Op

era

ting

Co

nd

ition

s: Item

Nu

mb

er R

aw W

ater Param

eter

Co

nd

ition

for O

peratio

n

Details

ICS

-ST

P

(Sed

imen

t, Taste &

Od

or /

Po

lyHalt

®)

Bacteria

Ch

lorin

e C

ollo

idal Iro

n

Hard

ness

Hyd

rocarb

on

s, oils, o

r lub

ricants

Hyd

rog

en S

ulfid

e Iro

n &

Man

gan

ese (Clear O

nly)

Iron

& M

ang

anese (C

olo

red)

Iron

Bacte

ria O

rgan

ic Iron

p

H

Sed

imen

t S

ilica Tan

nin

/ Org

anics

Turb

idity

No

ne A

llow

ed

<3 p

pm

N

A

Max 25 g

rains (4

27 pp

m)

No

ne A

llow

ed

N

on

e Allo

we

d

<6 pp

m C

om

bin

ed

<1 pp

m

No

ne A

llow

ed

N

on

e Allo

we

d

>6.0

and

<8.5

>5 micro

n

<100

pp

m

No

ne A

llow

ed

< 1 N

TU

Dim

ensio

ns

Co

nn

ection

M

ax Cap

acity B

est Treatmen

t Flo

w

Max F

low

M

ax Pressu

re

Min

Temp

erature

Max Tem

peratu

re N

o. o

f Filters

15.5" x 8" x 29

.5" 1” 12 m

on

ths

4-8

gp

m

15 gp

m

120 p

si 39

.2° F

113° F

2

Ge

ne

ral a

nd

Co

mm

on

Info

rma

tion

for a

ll ICS

Syste

ms:

If R

aw W

ater Param

eter Co

nd

ition

for O

peratio

n = “N

A” th

e systems w

ill no

t affect and

is no

t affected b

y con

centratio

ns o

f th

at param

eter typically fo

un

d in

drin

king

water

If R

aw W

ater Param

eter - C

on

ditio

n fo

r Op

eration

= “No

ne A

llow

ed” R

emo

ve thro

ug

h ad

equ

ate pre-treatm

en

t

If Raw

Water P

aramete

r - Co

nd

ition

for O

peratio

n = “N

ot fo

r extreme levels” Th

e cartridg

e usefu

l life may b

e sho

rtened

and

req

uire m

ore freq

uen

t rep

lacem

ent.

W

ater con

ditio

ns o

utsid

e of th

e abo

ve specified

limits m

ay lead to

a sho

rtened

filter life.

All stated

flow

rates are inte

rmitten

t flow

s. Co

nstan

t flow

s may affect resu

lts.

Extrem

e levels of an

y param

eter may sh

orte

n u

seful cartrid

ge life

Stated

“Max C

apacity” is ju

st that, it is th

e maxim

um

capacity o

f the filte

r. Yo

ur w

ater che

mistry m

ay redu

ce Max C

apacity

and

mo

re freq

uen

t filter rep

lacemen

t may b

e requ

ired

Iro

n an

d m

ang

anese treatm

en

t do

es no

t inclu

de iro

n in

the

follo

win

g fo

rms:

o Co

lloid

al (sub

micro

n sized

iron

particles)

o Org

anically B

ou

nd

(iron

that is b

ou

nd

to an

org

anic su

bstan

ce such

as tann

ins)

Typically, th

e presen

ce of co

lloid

al and

org

anic iro

n an

d m

ang

anese is d

eterm

ine

d afte

r the u

sual treatm

ents fo

r iron

and

m

ang

anese are in

ade

qu

ate or fail. Th

ere are sp

ecialty treatmen

ts for iro

n an

d m

ang

anese in

the co

lloid

al and

org

anic fo

rms.

Please co

ntact u

s for assistan

ce.

WA

RN

ING

: D

o n

ot u

se with

water th

at is micro

bio

log

ically un

safe or o

f un

kno

wn

qu

ality with

ou

t ade

qu

ate disin

fection

befo

re or after

un

it.

Page 36: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

   

 

O3 W

ater System

s, Inc. D

BA

– Cascad

ian W

ater 530

1 Airp

ort R

d. C

le Elu

m, W

A. 98

922 P

ho

ne 50

9-674-4

00

0 F

ax 509-674

-40

02 w

ww

.Cascad

ianW

ater.com

“Life’s Sh

ort – En

joy Yo

ur W

ater™”

CA

SC

AD

IAN

® ICS

-H S

pe

cificatio

ns a

nd

Op

era

ting

Co

nd

ition

s: Item

Nu

mb

er R

aw W

ater Param

eter

Co

nd

ition

for O

peratio

n

Details

ICS

-H

(Hyd

rog

en

Su

lfide –

Ro

tten E

gg

)

Bacteria

Ch

lorin

e C

ollo

idal Iro

n

Hard

ness

Hyd

rocarb

on

s, oils, o

r lub

ricants

Hyd

rog

en S

ulfid

e

Iron

& M

ang

anese (C

lear On

ly) Iro

n &

Man

gan

ese (Co

lored

) Iro

n B

acteria O

rgan

ic Iron

p

H

Sed

imen

t S

ilica Tan

nin

/ Org

anics

Turb

idity

No

ne A

llow

ed

NA

N

A

NA

N

on

e Allo

wed

N

ot fo

r extreme levels

<0.3 p

pm

<0

.3 pp

m

No

ne A

llow

ed

No

ne A

llow

ed

NA

N

A

<100

pp

m

No

ne A

llow

ed

< 1 NTU

Dim

ensio

ns

Co

nn

ection

M

ax Cap

acity B

est Treatmen

t Flo

w

Max F

low

M

ax Pressu

re M

in Tem

peratu

re M

ax Temp

erature

No

. of F

ilters O

ther

7.5" x 8.5" x 29.5"

1” 97,50

0 g

allon

s o

r 12 mo

nth

s 3-5 g

pm

8

gp

m

120 p

si 39

.2° F

113° F

1 Reco

mm

end

fo

llow

ing

with

an

ICS

-ST o

r ICS

S

TP

Ge

ne

ral a

nd

Co

mm

on

Info

rma

tion

for a

ll ICS

Syste

ms:

If R

aw W

ater Param

eter Co

nd

ition

for O

peratio

n = “N

A” th

e systems w

ill no

t affect and

is no

t affected b

y con

centratio

ns o

f th

at param

eter typically fo

un

d in

drin

king

water

If R

aw W

ater Param

eter - C

on

ditio

n fo

r Op

eration

= “No

ne A

llow

ed” R

emo

ve thro

ug

h ad

equ

ate pre-treatm

en

t

If Raw

Water P

aramete

r - Co

nd

ition

for O

peratio

n = “N

ot fo

r extreme levels” Th

e cartridg

e usefu

l life may b

e sho

rtened

and

req

uire m

ore freq

uen

t rep

lacem

ent.

W

ater con

ditio

ns o

utsid

e of th

e abo

ve specified

limits m

ay lead to

a sho

rtened

filter life.

All stated

flow

rates are inte

rmitten

t flow

s. Co

nstan

t flow

s may affect resu

lts.

Extrem

e levels of an

y param

eter may sh

orte

n u

seful cartrid

ge life

Stated

“Max C

apacity” is ju

st that, it is th

e maxim

um

capacity o

f the filte

r. Yo

ur w

ater che

mistry m

ay redu

ce Max C

apacity

and

mo

re freq

uen

t filter rep

lacemen

t may b

e requ

ired

Iro

n an

d m

ang

anese treatm

en

t do

es no

t inclu

de iro

n in

the

follo

win

g fo

rms:

o Co

lloid

al (sub

micro

n sized

iron

particles)

o Org

anically B

ou

nd

(iron

that is b

ou

nd

to an

org

anic su

bstan

ce such

as tann

ins)

Typically, th

e presen

ce of co

lloid

al and

org

anic iro

n an

d m

ang

anese is d

eterm

ine

d afte

r the u

sual treatm

ents fo

r iron

and

m

ang

anese are in

ade

qu

ate or fail. Th

ere are sp

ecialty treatmen

ts for iro

n an

d m

ang

anese in

the co

lloid

al and

org

anic fo

rms.

Please co

ntact u

s for assistan

ce.

WA

RN

ING

: D

o n

ot u

se with

water th

at is micro

bio

log

ically un

safe or o

f un

kno

wn

qu

ality with

ou

t ade

qu

ate disin

fection

befo

re or after

un

it.

Page 37: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

   

 

O3 W

ater System

s, Inc. D

BA

– Cascad

ian W

ater 530

1 Airp

ort R

d. C

le Elu

m, W

A. 98

922 P

ho

ne 50

9-674-4

00

0 F

ax 509-674

-40

02 w

ww

.Cascad

ianW

ater.com

“Life’s Sh

ort – En

joy Yo

ur W

ater™”

CA

SC

AD

IAN

® ICS

-SP

U S

pe

cificatio

ns a

nd

Op

era

ting

Co

nd

ition

s: Item

Nu

mb

er R

aw W

ater Param

eter

Co

nd

ition

for O

peratio

n

Details

ICS

-SP

U

(Sed

imen

t / P

olyH

alt®

Po

int o

f Use)

Bacteria

Ch

lorin

e C

ollo

idal Iro

n

Hard

ness

Hyd

rocarb

on

s, oils, o

r lub

ricants

Hyd

rog

en S

ulfid

e Iro

n &

Man

gan

ese (Clear O

nly)

Iron

& M

ang

anese (C

olo

red)

Iron

Bacte

ria O

rgan

ic Iron

p

H

Sed

imen

t S

ilica Tan

nin

/ Org

anics

Turb

idity

No

ne A

llow

ed

N

A

NA

M

ax 15 grain

s (256 p

pm

) N

on

e Allo

we

d

No

ne A

llow

ed

<6 p

pm

Co

mb

ined

N

A

No

ne A

llow

ed

No

ne A

llow

ed

>6.0

and

<8.5

>20 m

icron

<50

pp

m

No

ne A

llow

ed

< 1 N

TU

Dim

ensio

ns

Co

nn

ection

M

ax Cap

acity B

est Treatmen

t Flo

w

Max F

low

M

ax Pressu

re

Min

Temp

erature

Max Tem

peratu

re N

o. o

f Filters

5" x 5" x 14"

3/4”

6-12 m

on

ths

1-5 gp

m

5 gp

m

125 psi

40

° F

113° F

1

Ge

ne

ral a

nd

Co

mm

on

Info

rma

tion

for a

ll ICS

Syste

ms:

If R

aw W

ater Param

eter Co

nd

ition

for O

peratio

n = “N

A” th

e systems w

ill no

t affect and

is no

t affected b

y con

centratio

ns o

f th

at param

eter typically fo

un

d in

drin

king

water

If R

aw W

ater Param

eter - C

on

ditio

n fo

r Op

eration

= “No

ne A

llow

ed” R

emo

ve thro

ug

h ad

equ

ate pre-treatm

en

t

If Raw

Water P

aramete

r - Co

nd

ition

for O

peratio

n = “N

ot fo

r extreme levels” Th

e cartridg

e usefu

l life may b

e sho

rtened

and

req

uire m

ore freq

uen

t rep

lacem

ent.

W

ater con

ditio

ns o

utsid

e of th

e abo

ve specified

limits m

ay lead to

a sho

rtened

filter life.

All stated

flow

rates are inte

rmitten

t flow

s. Co

nstan

t flow

s may affect resu

lts.

Extrem

e levels of an

y param

eter may sh

orte

n u

seful cartrid

ge life

Stated

“Max C

apacity” is ju

st that, it is th

e maxim

um

capacity o

f the filte

r. Yo

ur w

ater che

mistry m

ay redu

ce Max C

apacity

and

mo

re freq

uen

t filter rep

lacemen

t may b

e requ

ired

Iro

n an

d m

ang

anese treatm

en

t do

es no

t inclu

de iro

n in

the

follo

win

g fo

rms:

o Co

lloid

al (sub

micro

n sized

iron

particles)

o Org

anically B

ou

nd

(iron

that is b

ou

nd

to an

org

anic su

bstan

ce such

as tann

ins)

Typically, th

e presen

ce of co

lloid

al and

org

anic iro

n an

d m

ang

anese is d

eterm

ine

d afte

r the u

sual treatm

ents fo

r iron

and

m

ang

anese are in

ade

qu

ate or fail. Th

ere are sp

ecialty treatmen

ts for iro

n an

d m

ang

anese in

the co

lloid

al and

org

anic fo

rms.

Please co

ntact u

s for assistan

ce.

WA

RN

ING

: D

o n

ot u

se with

water th

at is micro

bio

log

ically un

safe or o

f un

kno

wn

qu

ality with

ou

t ade

qu

ate disin

fection

befo

re or after

un

it.

Page 38: A Better Way to Treat Water · Water Problems and Notes. Cascadian ICS Solution Spots White spots on dishes, cars, windows, toilets, shower doors etc. that are hard to clean after

   

 

O3 W

ater System

s, Inc. D

BA

– Cascad

ian W

ater 530

1 Airp

ort R

d. C

le Elu

m, W

A. 98

922 P

ho

ne 50

9-674-4

00

0 F

ax 509-674

-40

02 w

ww

.Cascad

ianW

ater.com

“Life’s Sh

ort – En

joy Yo

ur W

ater™”

CA

SC

AD

IAN

® ICS

-TP

U S

pe

cificatio

ns a

nd

Op

era

ting

Co

nd

ition

s: Item

Nu

mb

er R

aw W

ater Param

eter

Co

nd

ition

for O

peratio

n

Details

ICS

-TP

U

(Taste & O

do

r / P

olyH

alt®

Po

int o

f Use)

Bacteria

Ch

lorin

e C

ollo

idal Iro

n

Hard

ness

Hyd

rocarb

on

s, oils, o

r lub

ricants

Hyd

rog

en S

ulfid

e Iro

n &

Man

gan

ese (Clear O

nly)

Iron

& M

ang

anese (C

olo

red)

Iron

Bacte

ria O

rgan

ic Iron

p

H

Sed

imen

t S

ilica Tan

nin

/ Org

anics

Turb

idity

No

ne A

llow

ed

<3 p

pm

N

A

Max 25 g

rains (4

27 pp

m)

No

ne A

llow

ed

N

on

e Allo

we

d

<6 pp

m C

om

bin

ed

<0.3 p

pm

N

on

e Allo

we

d

No

ne A

llow

ed

>6

.0 an

d <8

.5 >5 m

icron

<10

0 p

pm

N

on

e Allo

we

d

< 1 NTU

Dim

ensio

ns

Co

nn

ection

M

ax Cap

acity B

est Treatmen

t Flo

w

Max F

low

M

ax Pressu

re

Min

Temp

erature

Max Tem

peratu

re N

o. o

f Filters

5" x 5" x 14"

3/4”

6-12 m

on

ths

1-3 gp

m

5 gp

m

125 psi

40

° F

113° F

1

Ge

ne

ral a

nd

Co

mm

on

Info

rma

tion

for a

ll ICS

Syste

ms:

If R

aw W

ater Param

eter Co

nd

ition

for O

peratio

n = “N

A” th

e systems w

ill no

t affect and

is no

t affected b

y con

centratio

ns o

f th

at param

eter typically fo

un

d in

drin

king

water

If R

aw W

ater Param

eter - C

on

ditio

n fo

r Op

eration

= “No

ne A

llow

ed” R

emo

ve thro

ug

h ad

equ

ate pre-treatm

en

t

If Raw

Water P

aramete

r - Co

nd

ition

for O

peratio

n = “N

ot fo

r extreme levels” Th

e cartridg

e usefu

l life may b

e sho

rtened

and

req

uire m

ore freq

uen

t rep

lacem

ent.

W

ater con

ditio

ns o

utsid

e of th

e abo

ve specified

limits m

ay lead to

a sho

rtened

filter life.

All stated

flow

rates are inte

rmitten

t flow

s. Co

nstan

t flow

s may affect resu

lts.

Extrem

e levels of an

y param

eter may sh

orte

n u

seful cartrid

ge life

Stated

“Max C

apacity” is ju

st that, it is th

e maxim

um

capacity o

f the filte

r. Yo

ur w

ater che

mistry m

ay redu

ce Max C

apacity

and

mo

re freq

uen

t filter rep

lacemen

t may b

e requ

ired

Iro

n an

d m

ang

anese treatm

en

t do

es no

t inclu

de iro

n in

the

follo

win

g fo

rms:

o Co

lloid

al (sub

micro

n sized

iron

particles)

o Org

anically B

ou

nd

(iron

that is b

ou

nd

to an

org

anic su

bstan

ce such

as tann

ins)

Typically, th

e presen

ce of co

lloid

al and

org

anic iro

n an

d m

ang

anese is d

eterm

ine

d afte

r the u

sual treatm

ents fo

r iron

and

m

ang

anese are in

ade

qu

ate or fail. Th

ere are sp

ecialty treatmen

ts for iro

n an

d m

ang

anese in

the co

lloid

al and

org

anic fo

rms.

Please co

ntact u

s for assistan

ce.

WA

RN

ING

: D

o n

ot u

se with

water th

at is micro

bio

log

ically un

safe or o

f un

kno

wn

qu

ality with

ou

t ade

qu

ate disin

fection

befo

re or after

un

it.