CHARGING VALVE
SIGHT GLASS
FILTER-DRYER
BARE PIPE IN COVER
RADIATION COVER ONLY
FINNED TUBE RADIATION
FINNED TUBE RADIATION IN COVER
THERMOSTATIC EXPANSION VALVE
EVAPORATOR PRESSURE REGULATOR
MANUAL REFRIGERATION VALVE
STRAINER
FLANGED CONNECTION
SIAMESE HOSE CONNECTION
PIPE ANCHOR
EXPANSION JOINT
PIPE ALIGNMENT GUIDES
UNION
END CAP
CONCENTRIC REDUCER
TEE DOWN
TEE UP
ELBOW DOWN
ELBOW UP
TEMPERATURE SENSOR
HUMIDISTAT
DUCT THERMOSTAT (ELECTRIC)
ROOM THERMOSTAT (HEAT/COOL)
ROOM THERMOSTAT (COOL)
DUCT THERMOSTAT (PNEUMATIC)
FLOW METER
MOTORIZED DAMPER
DIFFERENTIAL PRESSURE TRANSMITTER
ROOM THERMOSTAT (HEAT)
SAFETY/PRESSURE RELIEF VALVE
FLOW CONTROL VALVE
MAKEUP WATER VALVE
PRESSURE REDUCING VALVE
CHECK VALVE
BALANCING VALVE
VERTICAL SHUT-OFF/IN VERTICAL PIPE
SHUT-OFF VALVE
SHOCK ABSORBER
AIR CHAMBER
(DOWN IN ARROW DIRECTION)
PIPE PITCH ARROW
PRESSURE GAUGE
AUTOMATIC AIR VENT
COMPOUND GAUGE
FLEX CONNECTOR
CONDENSER WATER RETURN
GROUND LOOP WATER RETURN
REFRIGERANT DISCHARGE
REFRIGERANT SUCTION
REFRIGERANT LIQUID
CONDENSER WATER SUPPLY
CHILLED WATER SUPPLY
CHILLED WATER RETURN
GROUND LOOP WATER SUPPLY
PENDANT SPRINKLER HEAD
UPRIGHT SPRINKLER HEAD
FIRE PROTECTION PIPING
POST INDICATOR VALVE
FIRE HYDRANT
FUEL OIL RETURN
FUEL OIL SUPPLY
INVERTED BUCKET TRAP
FLOAT & THERMOSTATIC TRAP
HEATING WATER RETURN
HEATING WATER SUPPLY
LOW PRESSURE CONDENSATE RETURN
LOW PRESSURE STEAM
RETURN OR EXHAUST DUCT DOWN
RETURN OR EXHAUST DUCT UP
FIRE DAMPER (FD) IN DUCT
SUPPLY DUCT DOWN
VOLUME DAMPER
SUPPLY DUCT UP
FUEL OIL VENT
FLOW ARROW
TEMP/PRESSURE RELIEF VALVE
SPRINKLER HEAD
DRY STANDPIPE
DRY PIPE SPRINKLER PIPING
PRE-ACTION SPRINKLER PIPING
ELBOW
TEE
CLEANOUTS
FLOOR DRAIN
STORM WATER (SUSPENDED)
TEMPERED WATER
GAS
DRAIN LINE
SANITARY WASTE (SUSPENDED)
SANITARY WASTE (BURIED)
SANITARY VENT LINE
STORM WATER (BURIED)
COLD SOFT WATER
HOT WATER (180° F)
HOT WATER RETURN (140° F)
HOT WATER (140° F)
HOT WATER RETURN
HOT WATER
140°
GAS METER
WATER METER
TAMPER SWITCH
FLOW SWITCH
PIPE SLEEVE
HOT SOFT WATER
HOT SOFT WATER RETURN
CONTROL VALVE (TCV)
3-WAY CONTROL VALVE
WET FIRE PROTECTION PIPING
REFRIGERANT HOT GAS
HOT WATER RETURN (180° F)
MEDIUM PRESSURE STEAM
HIGH PRESSURE STEAM
MEDIUM PRESSURE CONDENSATE RETURN
HIGH PRESSURE CONDENSATE RETURN
THERMOSTATIC TRAP
THROTTLING VALVE
PETE'S PLUG
FD
CARBON DIOXIDE SENSOR
VARIABLE FREQUENCY DRIVE
TEMPERATURE CONTROL PANEL
ACCESS PANEL
BOILER FEED WATER
EMERGENCY BOILER FEED WATER
COLD WATER
140°
180°
180°
T
CSW
HSW
HSWR
NON-POTABLE WATER
NPW
G
AIR (WITH PSI)A
D
GM
WM
RPBP
RPZ
(REDUCED PRESSURE
BACKFLOW PREVENTER)
CS
CR
CHWS
CHWR
GS
GR
{
HS
HR
FOS
FOR
FOV
RD
RS
RL
RHG
DUAL TEMPERATURE SUPPLYDTS
DUAL TEMPERATURE RETURNDTR
BFW
EBFW
LPS
MPS
HPS
LPR
MPR
HPR
CONDENSATE PUMP DISCHARGEPD
CONDENSATE RETURNCR
F&T
IB
T
ECCENTRICAL REDUCER
CO
FD
D
F
DS
DP
PA
WP
PIV
TS
FS
COMBINATION FIRE/SMOKE DAMPER
(FSD) IN DUCT
FSD
SD
SMOKE DAMPER (SD) IN DUCT
AP
INTERNAL LINED DUCT
CO
2
FLOW SWITCH
FS
FM
DPT
M
VFD
TCP
WELL WATERWW
8"E.
DENOTED
EXISTING
WORK
CONNECTION
TO EXISTING
SECTION OR ELEVATION
NUMBER
THERMOMETER
T
S
T
H
T
H,C
T
C
T
T
E
H
T
DENOTED
NEW WORK
SIZE OF
PIPE OR
DUCT
DENOTED
EXISTING
SHEET NUMBER OF
SECTION OR ELEVATION
DETAIL (LETTER)
SHEET NUMBER OF
DETAIL LOCATION
AD
AFC
AFF
AHR
AHU
ALT
AP
AS
BD
BDD
BTU
BV
CB
CI
CL
CO
COND
CONV
CUH
CW
DB
DF
DIA
DIFF
DS
DXC
EA
EAT
EBBR
EC
EG
ECONV
ECUH
EF
ELEC
ELEV
EOM
EPUH
ER
ERCP
ESP
EWC
EWH
EXPT
E.
FD
FPVAV
FOB
FSD
FTR
GC
GEN
HB
HTG
HW
HWR
HYD
ID
INV. EL.
LAT
LAV
MBH
MECH
MH
MC
MS
MUV
NC
NO
OA
OAD
OBD
OD
ORD
OSD
PFHX
PIV
PLBG
PRV
PUH
RA
RAD
RCP
RCNP
RD
RECIRC
RG
RPZ
RR
RIV
RRV
SA
SAN
SD
SG
SHDR
SK
SR
SS
STHX
TCC
TCP
TG
TO
TP
TYP
UR
VAV
VCP
VFD
VS
VSD
VTR
W
WB
WC
WS
ABBREVIATIONSTEMPERATURE CONTROL/MONITORING
DRAWING NOTATIONS
SECTIONS AND DETAILS
RADIATION SYMBOLS
DUCT SYMBOLS
FIRE PROTECTION SYSTEM
STEAM PIPING
HVAC PIPING
VALVES
REFRIGERATION VALVES/FITTINGS
PLUMBING
PIPE FITTINGS
GENERAL NOTES
1. ALL NEW WORK IS DRAWN DARK. ALL WORK DRAWN LIGHT AND FOLLOWED
BY (E.) IS EXISTING. ALL WORK SHALL REMAIN UNLESS SPECIFICALLY
NOTED OTHERWISE.
2. THESE NOTES APPLY TO EACH AND EVERY 'M' AND 'FP' SERIES DRAWINGS.
3. FIELD VERIFY ALL EXISTING CONDITIONS AS TO EXACT SERVICE, LOCATION,
TYPE OF MATERIAL, ETC. BEFORE BIDDING AND BEFORE BEGINNING
RENOVATION WORK.
4. COORDINATE ALL SHUT-DOWNS, DELIVERY, AND STORAGE OF MATERIALS,
ETC. WITH OWNER'S REPRESENTATIVE.
5. CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURING
CONSTRUCTION. ANY AND ALL OWNER FACILITIES DAMAGED OR
DISCONNECTED BY CONTRACTOR OPERATIONS SHALL BE FULLY
RESTORED TO PREVIOUS OPERATING AND APPEARANCE CONDITION BY
CONTRACTOR.
6. PROVIDE SLEEVES FOR ALL PIPING AND DUCTWORK THAT PENETRATES
FULL HEIGHT WALLS, WHETHER SHOWN OR NOT. HOLES THROUGH
EXISTING WALLS TO BE CORE DRILLED OR DRILLED WITH HOLE SAW.
7. ADDITIONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING ARE
NOTED ON THOSE DRAWINGS.
8. ALL UNDERLINED EQUIPMENT IS SCHEDULED. SEE M400 SERIES DRAWINGS
SCHEDULES.
9. SMOKING, ALCOHOL, DRUGS, WEAPONS, AND CONTRABAND ARE STRICTLY
FORBIDDEN ON JOB SITE PROPERTY.
10. FIELD VERIFY EXACT SIZES OF EXISTING PIPING AND DUCT SYSTEMS
SHOWN TO BE CONNECTED TO NEW WORK. IN THE EVENT ACTUAL SIZE
IS DIFFERENT THAN SHOWN ON DRAWINGS, CONTACT ENGINEER FOR
DIRECTION PRIOR TO ANY WORK.
11. FOR WALLS THAT GO TO DECK, REFERENCE THE 'A' SERIES DRAWINGS.
CONTRACTOR SHALL PROVIDE ACOUSTIC SEALANT AROUND ALL DUCT AND
PIPE PENETRATIONS THROUGH FULL HEIGHT WALLS.
ACID WASTE (SUSPENDED)
ACID WASTE (BURIED)
CONDENSATE DRAINCD
FCV
SHUT-OFF VALVE
AREA DRAIN
AUTOMATIC FLOW CONTROL
ABOVE FINISHED FLOOR
AIR HOSE REEL
AIR HANDLING UNIT
ALTERNATE
ACCESS PANEL
AIR SEPARATOR
BLOWDOWN
BACKDRAFT/PRESSURE RELIEF DAMPER
BRITISH THERMAL UNIT
BALANCE VALVE
CATCH BASIN
CAST IRON
CENTERLINE
CLEANOUT
CONDENSATE
HYDRONIC CONVECTOR
CABINET UNIT HEATER
COLD WATER
DRY BULB
DRINKING FOUNTAIN
DIAMETER
DIFFUSER
DOWNSPOUT
DIRECT EXPANSION COOLING COIL
EXHAUST AIR
ENTERING AIR TEMPERATURE
ELECTRIC BASEBOARD RADIATION
ELECTRICAL CONCTRACTOR
EXHAUST GRILLE
ELECTRIC CONVECTOR
ELECTRIC CABINET UNIT HEATER
EXHAUST FAN
ELECTRICAL
ELEVATION
END OF MAIN DRIP
ELECTRIC PROPELLER UNIT HEATER
EXHAUST REGISTER
ELECTRIC RADIANT CEILING PANEL
EXTERNAL STATIC PRESSURE
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
EXPANSION TANK
EXISTING
FLOOR DRAIN OR FIRE DAMPER
FAN POWERED VAV
FLAT ON BOTTOM
COMBINATION FIRE/SMOKE DAMPER
HYDRONIC FINNED TUBE RADIATION
GENERAL CONTRACTOR
GENERAL
HOSE BIBB
HEATING
HOT WATER
HOT WATER RETURN
WALL HYDRANT
INTERNAL DIAMETER
INVERTED ELEVATION
LEAVING AIR TEMPERATURE
LAVATORY
1000 BTU/HOUR
MECHANICAL
MANHOLE
MECHANICAL CONTRACTOR
MOP SINK
AUTOMATIC MAKE-UP VALVE
NORMALLY CLOSED
NORMALLY OPEN
OUTSIDE AIR
OUTSIDE AIR DAMPER
OPPOSED BLADE DAMPER
OUTSIDE DIAMETER
OVERFLOW ROOF DRAIN
OPEN SITE DRAIN
PLATE AND FRAME HEAT EXCHANGER
POST INDICATOR VALVE
PLUMBING
PRESSURE REDUCING VALVE
PROPELLER UNIT HEATER
RETURN AIR
RETURN AIR DAMPER
HYDRONIC RADIANT CIELING HEATING PANEL
REINFORCED CONCRETE PIPE
ROOF DRAIN
RECIRCULATING
RETURN GRILLE
REDUCED PRESSURE BACKFLOW PREVENTER
RETURN REGISTER
ROOF INTAKE VENT
ROOF RELIEF VENT
SUPPLY AIR
SANITARY
SMOKE DAMPER
SUPPLY GRILLE
SHOWER DRAIN
SINK
SUPPLY REGISTER
STAINLESS STEEL
SHELL AND TUBE HEAT EXCHANGER
TEMPERATURE CONTROL CONTRACTOR
TEMPERATURE CONTROL PANEL
TRANSFER GRILLE
TRANSFER OPENING
TRAP PRIMER LINE
TYPICAL
URINAL
VARIABLE AIR VOLUME
VETRIFIED CLAY PIPE
VARIABLE FREQUENCY DRIVE
VENT STACK
VARIABLE SPEED DRIVE
VENT THROUGH ROOF
WASTE
WET BULB
WATER CLOSET
WASTE STACK
ROOM NUMBER
UNIT
UNDERLINED REPRESENTS
SCHEDULED EQUIPMENT
FAN COIL CFM
FAN COIL SIZE
UNIT/AREA LOCATION IN BUILDING
NUMBER OF AHU IN UNIT
UNDERLINED REPRESENTS
SCHEDULED EQUIPMENT
UNIT/AREA LOCATION IN BUILDING
NUMBER OF FAN IN UNIT
UNDERLINED REPRESENTS
SCHEDULED EQUIPMENT
FAN COIL CFM
UNIT/AREA LOCATION IN BUILDING
UNDERLINED REPRESENTS
SCHEDULED EQUIPMENT
VAV CFM
VAV SIZE - SEE SCHEDULE
DRAWN TO SCALE (ACTUAL SIZE)
ACTUAL SIZE
SQUARE DIFFUSER DRAWN TO
SCALE (ACTUAL SIZE)
CFM
CFM
LINEAR SLOT DIFFUSER DRAWN
TO SCALE (ACTUAL SIZE)
CFM
ER - EXHAUST REGISTER
RG - RETURN GRILL
SIZE
SUPPLY REGISTER
CFM
FC - FAN COIL
BC - BLOWER COIL
FC-128G
C-1280
AHU-A4
EF-B6
400
VAV-123A
A-120
FAN COIL
AIR HANDLING UNIT
FAN
VARIABLE AIR
VOLUME BOX
DOUBLE DEFLECTION
SUPPLY REGISTER
EXHAUST/RETURN REGISTER
SUPPLY DIFFUSER
RETURN GRILL FOR RETURN
AIR PLENUM CEILING
EF - EXHAUST FAN
SF - SUPPLY FAN
RF - RETURN FAN
24/12
400
400
1400 ER
28/12 SR;300
NOMENCLATURE FOR SCHEDULED DEVICES
(SEE SCHEUDLES M600 SERIES DRAWINGS FOR ADDITIONAL INFORMATION)
VF - VENTILATION FAN
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
NORTH
PARTIAL FIRST FLOOR PLAN - MECHANICAL DEMOLITION
SCALE: 1/4" = 1'-0"
GENERAL NOTES
1. SEE DRAWING M001 FOR ADDITIONAL GENERAL NOTES.
PLAN NOTES
1DISCONNECT AND REMOVE PLUMBING FIXTURE, CARRIER AND
ASSOCIATED WATER, WASTE AND VENT PIPING TO A POINT BEYOND
FINISHED SURFACE AND CAP.
DISCONNECT AND REMOVE FLOOR DRAIN AND ASSOCIATED WASTE
PIPING TO A POINT BELOW FLOOR AND CAP. CUT AND PATCH FLOOR TO
MATCH EXISTING.
DISCONNECT AND REMOVE PLUMBING FIXTURE AND CARRIER.
ASSOCIATED WATER, WASTE AND VENT PIPING TO REMAIN. REFER TO
DRAWING M201 FOR ADDITIONAL INFORMATION.
REMOVE AND RELOCATE THERMOSTAT. SEE M211.
WORK SHOWN IN OFFICE 101F SHALL BE PERFORMED UNDER
ALTERNATE #1. BASE BID = NO WORK, EXISTING TO REMAIN.
HVAC AND FIRE PROTECTION WORK SHOWN IN CORRIDOR 101G,
RELATED TO CEILING REPLACEMENT, SHALL BE PERFORMED UNDER
ALTERNATE #3. BASE BID = NO WORK, EXISTING TO REMAIN.
2
3
EXISTING WORK TO
BE REMOVED
EXISTING WORK
TO REMAIN
DEMOLITION LEGEND
FSD
FSD
FSD
RG 750
RG 200
RG 200
RG 200
RG 250
RG 240
RG 200
RG 200
EG 125
EG 125
EG 300
EG 300
TG
EG 200
TG
EG 300EG 300
TG 16"x8"
FPB-117 E.FPB-116 E.
FPB-118 E.
FPB-114 E.
VAV-113 E.
VAV-124 E.
VAV-121 E.
VAV-123 E.
VAV-129 E.
VAV-127 E.
FPB-119 E.
T
FPB-114
T
FPB-116
TFPB-117
T FPB-118
T
FPB-119
T
VAV-121
T
VAV-123
T
VAV-124
T
VAV-113
T
VAV-129
T
VAV-127
260
200
200200
200
200
200200
200
110110110
110
110110
75
75
200
240
100 100
8"Ø E.
8"Ø E.
8"Ø E.
6"Ø E.
8"Ø E.
6"Ø E.
6"Ø E.
11"Ø E.
14"Ø E.
7"Ø E.
17"Ø E.
19"Ø E.
20"Ø E.
23"Ø E.
6"/6" E.
8"Ø E.
6"Ø E.
6"Ø E.
8"Ø E.
8"Ø E.
6"Ø E.
14"/10" E.
14"/10" E.
8"/10" E.
8"/10" E.
8"Ø E.
8"Ø E.
8"Ø E.
8"Ø E.
6"Ø E.
6"Ø E.
6"/6" E.
5"Ø E.
10"/8" E. 6"/6" E.
6"Ø E.
6"Ø E.
7"Ø E.
6"Ø E.
6"Ø E.
6"/6" E.
10"/8" E.
13"Ø E.
13"Ø E.
8"Ø E.
14"Ø FLUE E. UP
14"Ø EA E. UP
30"/26" RA E. UP
30"/26" E.
22"/12" E.
24"Ø E.
26"Ø EA E. UP
33"Ø SA E. UP
22"Ø E.
14"/12" E.
14"/8" E.
10"Ø E.
10"Ø E.
7"Ø E.
7"Ø E.
7"Ø E.
14"/12" E. 14"/10" E.
8"Ø E.
10"Ø E.
10"Ø E.
26"/12" E.
26"/12" E.
12"/12" E.
8"Ø E.
8"Ø E.
8"Ø E.
8"Ø E.
18"/12" E.
8"Ø E.
8"Ø E.
8"Ø E.
14"/10" E.
2
1
1
3
TYPICAL EXISTING SPRINKLER
HEAD. SEE M201 FOR WORK.
4
4
4
4
4
4
5
5
6
6
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
NORTH
PARTIAL FIRST FLOOR PLAN - MECHANICAL
SCALE: 1/4" = 1'-0"
GENERAL NOTES
1. SEE DRAWING M001 FOR ADDITIONAL GENERAL NOTES.
2. PROVIDE TEST AND BALANCE FOR ALL TERMINAL UNITS,
DIFFUSERS AND GRILLES IMPACTED BY THIS PROJECT TO ACHIEVE
CFMS NOTED.
3. INSTALL NEW FILTERS FOR FAN POWERED VAV TERMINAL UNITS
PRIOR TO BALANCING.
PLAN NOTES
1ELECTRIC WATER COOLER EQUAL TO HALSEY TAYLOR HTHB-HAC8WF.
MOUNT AT 36" TO BUBBLER AND CONNECT TO EXISTING WATER, WASTE
AND VENT PIPING. REWORK EXISTING ROUGH-INS AS REQUIRED.
EXISTING SPRINKLER HEAD TO REMAIN. REWORK FOR NEW CEILING AS
REQUIRED.
DISCONNECT AND REMOVE EXISTING SPRINKLER HEAD. EXTEND
ARM-OVER PIPING AS SHOWN AND INSTALL NEW SPRINKLER HEAD AND
ESCUTCHEON TO MATCH EXISTING. CENTERED IN 2'X2' CEILING TILE.
REMOVE EXISTING SPRINKLER HEAD AND PIPING BACK TO MAIN AND
CAP.
14/10 INTERNALLY LINED Z-SHAPED TRANSFER AIR DUCT ABOVE
CEILING.
WORK SHOWN IN OFFICE 101F, FOR THAT OFFICE, SHALL BE
PERFORMED UNDER ALTERNATE #1. BASE BID = NO WORK, EXISTING TO
REMAIN. VAV-101E SHALL BE BASE BID. REMOVE AND REINSTALL
EXISTING CEILING AS REQUIRED.
WORK SHOWN IN CORRIDOR 101G, FOR THE CORRIDOR, SHALL BE
PERFORMED UNDER ALTERNATE #3. BASE BID = NO WORK, EXISTING TO
REMAIN. ONLY PERFORM WORK REQUIRED BY NEW WALL
CONSTRUCTION.
RENOVATION LEGEND
WORK TO BE INSTALLED.
EXISTING WORK TO REMAIN.
FSD
FSD
FSD
RG 200
RG 200
RG 200
EG 125
EG 300
EG 300
TG
EG 200
TG
EG 300EG 300
TG 16"x8"
FPB-117 E.FPB-116 E.
FPB-118 E.
FPB-114 E.
VAV-113 E.
VAV-124 E.
VAV-121 E.
VAV-123 E.
VAV-129 E.
VAV-127 E.
FPB-119 E.
200
200200
110110110
110
110110
8"Ø E.
8"Ø E.
8"Ø E.
6"Ø E.
8"Ø E.
6"Ø E.
6"Ø E.
11"Ø E.
14"Ø E.
7"Ø E.
17"Ø E.
19"Ø E.
20"Ø E.
23"Ø E.
8"Ø E.
6"Ø E.
6"Ø E.
14"/10" E.
6"Ø E.
6"/6" E.
5"Ø E.
10"/8" E.6"/6" E.
6"Ø E.
6"Ø E.
7"Ø E.
6"Ø E.
6"Ø E.
6"/6" E.
10"/8" E.
13"Ø E.
13"Ø E.
8"Ø E.
14"Ø FLUE E. UP
14"Ø EA E. UP
30"/26" RA E. UP
30"/26" E.
22"/12" E.
24"Ø E.
26"Ø EA E. UP
33"Ø SA E. UP
22"Ø E.
14"/12" E.
14"/8" E.
10"Ø E.
10"Ø E.
7"Ø E.
7"Ø E.
7"Ø E.
14"/12" E. 14"/10" E.
8"Ø E.
10"Ø E.
10"Ø E.
26"/12" E.
26"/12" E.
12"/12" E.
8"Ø E.
8"Ø E.
8"Ø E.
8"Ø E.
18"/12" E.
8"Ø E.
8"Ø E.
8"Ø E.
14"/10" E.
260
240
200
100
200
200
200 200
250250
CAP EA DUCT
VAV-101E
T
VAV-120
10"Ø 10"Ø
14/10
8"Ø
14"/10"
14"/10"
8"Ø
8"Ø
8"Ø
8"Ø
8"Ø
10"Ø
CAP DUCT
14"/8"
1
T
VAV-101E
B
M401
2
3
2
2
2
2
4
4
3
3
3
3
3
3
3
3
3
3
3
3
3
3
2
14"/10"
10"Ø
10"Ø
6"Ø
500
12"Ø
T
VAV-124
5
5
8"Ø
200 RG
400 RG
500 RG
200 RG
200 RG
200 RG
10"Ø
6
7
6
7
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
NORTH
PARTIAL FIRST FLOOR PLAN - HYDRONIC
SCALE: 1/4" = 1'-0"
GENERAL NOTES
1. SEE DRAWING M001 FOR ADDITIONAL GENERAL NOTES.
2. CHECK AND RECALIBRATE EXISTING THERMOSTATS.
PLAN NOTES
1INSTALL THERMOSTAT AT THIS LOCATION.
FPB-117 E.FPB-116 E.
FPB-118 E.
FPB-114 E.
VAV-113 E.
VAV-124 E.
VAV-121 E.
VAV-123 E.
VAV-129 E.
VAV-127 E.
FPB-119 E.
HWS
HWR
HW
S
HW
R
HW
S
HW
R
HW
S
HW
R
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"3/4"
3/4"
1 1/4"
1"
1"
3/4"
3/4"
RENOVATION LEGEND
WORK TO BE INSTALLED.
EXISTING WORK TO REMAIN.
VAV-101E
HWS
HWR
3/4"
A
M401
T
FPB-119
T
VAV-101E
T
FPB-114
T
FPB-116
T
FPB-117
T FPB-118
T
VAV-121
T
VAV-113 T
VAV-124
1
1
1
1
1
CONTROLS NOTES
1. ALL CONTROLS WORK SHALL BE BY JOHNSON CONTROLS LOCAL
BRANCH OFFICE.
2. RECALIBRATE EXISTING THERMOSTATS.
3. VAV BOX SHALL UTILIZE 120V CONTROLS.
4. T.C.C. SHALL COORDINATE AND UPDATE ROOM NUMBERING, AND
EQUIPMENT NOMENCLATURE, AS REQUIRED, FOR THE PROJECT
AREA.
T
VAV-123
1
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
SUPPLY
RETURN
PETE'S PLUG (TYP)
HYDRONIC
COIL
2-WAY TCC VALVE UNLESS
CONTROL VOLTAGE TO MATCH
UNION (TYPICAL)
DRAIN WITH HOSE
END, VALVE & CAP
CONTROL VALVE
AUTO FLOW
AT HIGH POINT
MANUAL AIR VENT
STRAINER
SHUTOFF
VALVE
DIRECTION
OF FLOW
DETAIL 'A'
TERMINAL UNIT HYDRONIC COIL PIPING
WITH 2-WAY VALVE DETAIL
NO SCALE
NOTE: OFF-SET PIPING
FOR EASY COIL REMOVAL
400 ACTUAL CFM
SQUARE SUPPLY DIFFUSER
CEILING DIFFUSER SCHEDULE
MARK
NO.
SPECIFICATION
NAME
MANUFACTURER
AND MODEL NO.
CFM
RANGE
MAX.
N.C.
NECK
DIA.
FACE SIZE
CEILING
MODULE
SIZE
60 - 135 SQUARE CEILING
DIFFUSER
PRICE SCDA OR
EQUAL
100 - 135 15 6" 12/12 24/24
210 - 245 SQUARE CEILING
DIFFUSER
PRICE SCDA OR
EQUAL
210 - 245 19 8" 24/24 24/24
250 - 325 SQUARE CEILING
DIFFUSER
PRICE SCDA OR
EQUAL
250 - 325 19 10" 24/24 24/24
330 - 475 SQUARE CEILING
DIFFUSER
PRICE SCDA OR
EQUAL
330 - 475 19 12" 24/24 24/24
480 - 645 SQUARE CEILING
DIFFUSER
PRICE SCDA OR
EQUAL
480 - 645 18 14" 24/24 24/24
650 - 735 SQUARE CEILING
DIFFUSER
PRICE SCDA OR
EQUAL
650 - 735 18 15" 24/24 24/24
1400 EG
CFM
EG - EXHAUST GRILLE
RG - RETURN GRILLE
MARK NO
EXHAUST/RETURN REGISTER SCHEDULE
MARK NO.
NOMINAL
GRILLE SIZE
MAX N.C. MAX ΔP CFM RANGE REMARKS
0-200 8/8 25 .1 0-200 -
225-450 12/12 25 .1 225-450 -
455-800 16/16 25 .1 455-800 -
805-1050 20/20 25 .1 805-1050 -
1055-1400 24/24 25 .1 1055-1400 -
VARIABLE AIR VOLUME BOX SCHEDULE WITH HEAT (HOT WATER)
MARK
NO.
DRAWING
NAME &/OR
PURPOSE
SPECIFICATION
MANUFACTURER
& MODEL NO.
INLET DIA
(IN.)
CLG CFMHTG CFM
MAX APD
THRU BOX
AND COIL
HEATING DATA (*1)
INLET SP (IN.
W.G.)
REMARKS
SECTION NAME EQUIP TYPE MBH EAT LAT EWT LWT GPM
WPD
VAV-101E VAV BOX ZONE - AIR TERMINAL UNITS
VAV WITH
HYDRONIC
HEATING COIL
PRICE MODEL SDV5 10"Ø 500 375 .5 20.3 55 °F 105 °F 180 °F 140 °F 1.0 1.0 1.00" TWO-ROW COIL
NOTES:
1. HEATING DATA RUN AT 75% OF VAV BOX MAXIMUM COOLING CFM. COIL AIR PRESSURE DROPS ARE AT FULL VAV BOX CFM.
3. MINIMUM COOLING CFM SHALL BE 50% OF THE VAV BOX COOLING CFM FOR THE ZONE.
4. SEE PLANS FOR UNITS WITHOUT HEATING COILS (COOLING COILS ONLY)
2. PERFORMANCE BASED ON 1.0" INLET SP (IN. W.G.) AND 0.25" DOWNSTREAM SP (IN. W.G.)VAV-123A
120
UNIT/AREA LOCATION IN THE BUILDING
VAV CFM
UNDERLINED REPRESENTS
SCHEDULED EQUIPMENT
ft. w.g.
NOTES:
BE REMOVED WITHOUT REMOVING SUPPORTS.
SUPPORT UNIT SO THAT BOTTOM ACCESS PANEL CAN
STRUCTURE ABOVE.
SUPPORT UNIT AT ALL FOUR CORNERS FROM
2.
1.
DETAIL 'B'
VAV BOX INSTALLATION
NO SCALE
3. SIZE OF ACCESS DOOR IN OUTLET DUCT SHALL BE
APPROXIMATELY 2/3'S THE WIDTH OF THE DUCT.
(MINIMUM SIZE SHALL BE 6/6)
DETAIL 'C'
BRANCH DUCT TAKE-OFF
FROM MAIN DUCT DETAIL
NO SCALE
VOLUME DAMPER
(TYPICAL)
45° TAKE-OFF BOOT.
IS 3'-0". DUCT SHALL
MAXIMUM FLEX LENGTH
BE ROUTED LEVEL. NO
TRANSITION FROM
RECTANGULAR TO ROUND.
DUCT MAIN - SEE
PLAN FOR SIZES.
AIR FLOW
DIRECTION OF
SHARP KINKS ALLOWED.
TO CONNECT DUCT TO SIDE OF PLENUM.
PLENUM TO BE TALL ENOUGH
DETAIL 'D'
RETURN GRILLE
NO SCALE
LAY-IN CEILING
VISIBLE FROM ROOM.
WALL SO FILTER NOT
BLADES ANGLED TOWARD
WALL
RETURN DUCT
PLENUM SUPPORTED FROM
STRUCTURE ABOVE.
EXISTING.
GENERAL NOTES (RENOVATION):
GENERAL NOTES (DEMOLITION):
1. FIELD VERIFY ALL EXTG. CONDITIONS PRIOR TO BEGINNING WORK. THESE
DRAWINGS DO NOT SHOW ALL REQUIRED DEMOLITION WORK. SOME
CONDITIONS MAY HAVE BEEN CONCEALED DURING FIELD SURVEYS.
2. ALL DEVICES AND EQUIPMENT SHOWN DASHED OR WITH HEAVY LINE WEIGHT
SHALL BE REMOVED IN THEIR ENTIRETY, INCLUDING ALL WIRING TO SOURCE,
UNLESS OTHERWISE NOTED.
3. DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE
& FEDERAL REGULATIONS.
4. CONTRACTORS SHALL PROTECT ALL EXTG. OWNER FACILITIES THAT ARE TO
REMAIN DURING CONSTRUCTION. ANY FACILITIES DAMAGED OR
DISCONNECTED BY CONTRACTOR SHALL BE IMMEDIATELY RESTORED TO
PREVIOUS CONDITION.
5. OWNER SHALL HAVE "RIGHT OF FIRST REFUSAL" FOR ALL DEMOLISHED
ELECTRICAL ITEMS. CONTRACTOR SHALL COORDINATE WITH OWNER PRIOR
TO BEGINNING WORK TO DETERMINE WHAT ITEMS THE OWNER MAY BE
INTERESTED IN KEEPING.
6. FOR MECH. EQUIPMENT BEING REMOVED, REMOVE ALL ASSOCIATED
DISCONNECTS, CONTROLLERS, WIRING, ETC. COMPLETE. VERIFY W/ M.C.
7. FOR EQUIPMENT OR DEVICES BEING REMOVED FROM WALLS THAT WILL
REMAIN, PROVIDE A BLANK COVERPLATE (TO MATCH NEW) ON EXTG. BOX.
8. PROVIDE ADEQUATE SUPPORT FOR EXTG. CABLING/RACEWAYS ABOVE CEILING
AS REQ'D. REMOVE ALL OBSOLETE CABLING, WIRING, RACEWAYS, ETC.
9. REMOVE ALL ASSOCIATED ELECTRICAL FOR ANY EXISTING EQUIPMENT BEING
REMOVED BY ANY TRADE. REFER TO ALL DRAWINGS.
10. CONTRACTOR SHALL REMOVE ALL EXTG. DEVICES ON WALLS BEING REMOVED,
WHETHER DEVICES ARE SHOWN OR NOT, UNLESS OTHERWISE INSTRUCTED.
11. COORDINATE SCHEDULING OF DEMOLITION WORK WITH OWNER AND ALL
TRADES.
12. PATCH ALL EXTG. HOLES THRU WALLS AND FLOORS WHERE EXTG. RACEWAYS
OR CABLES ARE REMOVED.
13. IF SERVICE TO AN EXISTING DEVICE TO REMAIN IS INTERRUPTED BY THE
REMOVAL OF ANOTHER DEVICE, CONTRACTOR SHALL REWIRE THE EXISTING
DEVICE THAT IS TO REMAIN AS REQUIRED TO MAINTAIN OPERATION.
VIDEO SURVEILLANCE CAMERA (WALL)
PASSIVE INFRARED DETECTOR
KEYPAD
DOOR CONTACT
SPRINKLER TAMPER SWITCH
SPRINKLER FLOW SWITCH
FIRE ALARM STROBE
HEAT DETECTOR
DUCT TYPE SMOKE DETECTOR
SMOKE DETECTOR
MAGNETIC DOOR HOLDER
FIRE ALARM BELL
FIRE ALARM HORN (SPEAKER)-STROBE
MANUAL PULL STATION
FIRE ALARM ANNUNCIATOR
FIRE ALARM CONTROL PANEL
LABORATORY EQUIPMENT COMPANY (CONTRACTOR)
EXISTING RELOCATED
EXISTING
EXPOSED
EXHAUST
EXISTING
EXISTING
EXTERIOR
EXCAVATION
EXIST
EXP
EXCAV
EXT
EXH
EXR
EXTG
EX
LV LOW VOLTAGE
EQUIPMENT GROUNDING CONDUCTOR
ENERGY MANAGEMENT SYSTEM
EXPLOSIONPROOF; ELECTRIC-PNEUMATIC
EXISTING TO REMAIN
ELECTRICAL METALLIC TUBING
EXTERIOR INSULATION FINISH SYSTEM
ELEVATOR; ELEVATION
ELECTRICIAN; ELECTRICAL; ELECTRONIC
ELECTRIC BASEBOARD RADIATION
ELECTRICAL CONTRACTOR
ELECTRONIC BALLAST
ELECTRIC WATER HEATER
ELECTRIC WATER COOLER
ENGINE; ENGINEERED
EMS
ENGINEER
ESTIMATED
ENCLOSURE
ENERGY SAVER
EQUIPMENT
EP
ER
EMT
EQUIP
ENCL
ENGR
ENG
EWH
EWC
EST
ES
EMERGENCY
EMERGENCY
EACH
EXHAUST FAN
EGC
EMERG
EM
EBBR
EC
EA
EB
EF
ELEV
ELECT
EIFS
DUSTPROOF; DOUBLE POLE
DUSTTIGHT; DOUBLE THROW
DOMESTIC HOT WATER
DIRECT DIGITAL CONTROL
DECIBEL; DIRECT BURIED
DEEP; DEPTH; DISCHARGE
DOUBLE POLE, SINGLE THROW
DOUBLE POLE, DOUBLE THROW
EQUIPMENT ONLY; EAST; ELECTRICAL; EXISTING
DISC DISCONNECT
DOWN
DISHWASHER
DIRECT EXPANSION
DRAWING
DISTRIBUTION
DN
DP
DT
DW
DX
DPST
DPDT
DWG
DIST
E
DRINKING FOUNTAIN
DIRECT CURRENT
DIFFUSER
DIAMETER
DIAGONAL
DIAMETER
D
DF
DHW
DDC
DC
DB
DIAM
DIAG
DIFF
DIA
LOCKED ROTOR AMPS
KILOVOLT AMPERE REACTIVE
LABOR; LABORATORY
KILOVOLT AMPERE
LAMP LUMEN DEPRECIATION
LONG; LENGTH; LARGE
LIGHT EMITTING DIODE
POUND; ELL CONDUIT BODY
LIGHT; LIQUID-TIGHT
LOW POWER FACTOR
LED
LRA
LG
LF
LM
LP
LO
LTR
LLD
LTG
LT
LPF
LINEAR FOOT
LUMEN
LOCKOUT
LETTER
LIGHTING
LIGHTING PANEL
KWH
KVA
KV
KP
KVAR
LAB
L
KWKW
LEC
LB
KILOWATT-HOUR
KILOVOLT
KEYPAD
LENGTH; LONG
KILOWATT
INCLUDED; INCLUDING
ISOLATED GROUND
THOUSAND CIRCULAR MILS
INVERT ELEVATION
INTERIOR; INTERNAL
JOULE; JUNCTION
INSULATION; INSULATED
KITCHEN EQUIPMENT CONTRACTOR
INTERMEDIATE METAL CONDUIT
INV EL
J-BOX
JB
KK
IS
KEC
K
J
KCMIL
KHZ
JUNCTION BOX
JUNCTION BOX
KIRK KEY
THOUSAND
INSTANT START
KILOHERTZ
IMP
IF
IG
INST
INCL
IN
INCAND
IMC
INT
INSUL
ENGINEERS
IMPEDANCE
INCH
INSTALLATION
INCANDESCENT
INSIDE FROSTED
RIGID STEEL CONDUIT
RT
RSC
RS
RAINTIGHT
RAPID START
RIGID NON-METALLIC CONDUIT
RUNNING LOAD AMPS
RECIRCULATING
RELAY CONTROL STATION
REFERENCE; REFRIGERATED
REVOLUTIONS PER MINUTE
ROOT MEAN SQUARE
RIGID GALVANIZED STEEL
POLYVINYL CHLORIDE
RESISTANCE; RELOCATED; RECESSED
REMOVE & REPLACE
REQ'D
REQUIRED
RNC
RLA
RMS
RGS
RF
RET
RPM
RR
R&R
RP
RETURN FAN
RETURN
RESTROOM
RAINPROOF
PU
RECEPT
QUAN
PWR
PVC
RCS
REF
RECIRC
R
PER UNIT
RECEPTACLE
POWER
QUANTITY
PROTECTIVE DEVICE
PUBLIC ADDRESS
POWER FACTOR CORRECTION CAPACITOR
POWER FACTOR
PUSHBUTTON; PULL BOX
POST INDICATOR VALVE
POUNDS PER SQUARE INCH GAUGE
POTENTIAL TRANSFORMER
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PROFESSIONAL ENGINEER
POWER CONNECTOR; PHOTOCELL
OUTSIDE SCREW AND YOKE
PH PHASE
PL
PNL
PIV
PR
PLBG
PKG
PT
PSIG
PSI
PSF
PRI
PILOT LIGHT
PANELBOARD
PLUMBING
PACKAGE
PAIR
PRIMARY
PD
PA
PF
PFCC
P
PC
PB
PE
OZ
OS&Y
POLE; PULL
OUNCE
PHASE; DIAMETER
APPROXIMATELY
POUND; NUMBER
'
"
°
O
~
@
%
#
FEET
INCHES
DELTA
DEGREE
AT
PERCENT
VAPORTIGHT
VERY HIGH OUTPUT
VERY HIGH FREQUENCY
VARIABLE FREQUENCY DRIVE
"WIREMOLD" (SURFACE RACEWAY)
WIRE GUARD
WELDER OUTLET
WEATHERPROOF
WEIGHT: WATERTIGHT
TRANSFORMER
WELDED WIRE FABRIC
EXTRA HEAVY DUTY
WIRE; WATT; WIDE; WEST; WASTE
WELL WATER; WARM WHITE
WO
WWF
WP
WT
Y
XHD
WW
XFER
XFMR
WYE
TRANSFER
VT
VHO
VHF
VFD
VERT
WG
W/
W
VOL
WM
VERTICAL
VOLUME
WITH
FOODSERVICE FACILITIES EQUIPMENT CONTRACTOR
CABINET UNIT HEATER
CONTROL POWER TRANSFORMER
CENTRAL OFFICE GROUND BAR
CONCRETE MASONRY UNIT
CONSTRUCTION MANAGER
CENTRAL STATION AIR CONDITIONER
COOL WHITE; COLD WATER; CLOTHES WASHER
CURRENT TRANSFORMER
CONDENSATE; CONDUCTOR
CONTINUOUS; CONTINUED; CONTRACTORCONT
CONTROL PANEL
CYLINDER
CUBIC FOOT
CUBIC YARD
COPPER; CUBIC
CUH
CP
CPT
CU FT
CSAC
CU
CT
CYL
CY
CW
COLUMN
COMBINATION
CENTRAL OFFICE
COOLING; CEILING
CONCRETE
COMPRESSOR
CM
CLG
COMB
COGB
CO
COL
CMU
COMPR
COND
CONC
BOLTED PRESSURE SWITCH
CONDUIT; CENTIGRADE
BELOW FINISHED GRADE
CLOSED CIRCUIT TELEVISION
CURRENT LIMITING FUSE
CHILLED WATER PUMP
CUBIC FEET; COMPACT FLUORESCENT
CANDELA; CLOTHES DRYER
CENTER TO CENTER
CABINETCAB
CIRCUIT
CAPACITY
CIRCUIT
CAST IN PLACE
CHILLED WATER
CIRCUIT BREAKER
CIR
CCTV
CB
CAP
CHWP
CHW
CIP
CF
CD
CLF
CKT
BRANCH
BREAKER
BATTERY
BOARD
BUILDING
BR
BRKR
BPS
BATT
BLDG
C
BFG
BD
C/C
INSTITUTE OF ELECTRICAL & ELECTRONICS
INTERMEDIATE DISTRIBUTION FRAME
HIGH PRESSURE SODIUM
HOURS PER DAY
HIGH POWER FACTOR
HAND-OFF-AUTOMATIC
HOT WATER; HEAVY WALL
HEATING WATER PUMP
HIGH SHORT CIRCUIT
INTERRUPTING CAPACITY
HEATING, VENTILATION & AIR-CONDITIONING
HORSEPOWER; HIGH PRESSURE
HEATERSHTRS
IEEE
HV
IDF
HW
HZ
HYD
HWP
HVAC
ID
IC
HIGHT VOLTAGE
HERTZ
HYDRAULIC
INSIDE DIAMETER
HO
HOA
HORIZ
HPS
HR
HPF
HP
HT
HTG
HSC
HRS/DAY
HORIZONTAL
HIGH OUTPUT
HOUR
HEIGHT
HEATING
GROUND FAULT PROTECTOR
GROUND FAULT CIRCUIT INTERRUPTER
GENERAL PURPOSE
GALVANIZED RIGID CONDUIT
HEATING, AIR CONDITIONING & REFRIGERATION
GENERAL CONTRACTOR
GROUND; GROUNDED
GALVANIZED RIGID STEEL
GALLONS PER MINUTE
GENERAL; GENERATOR
GROUND FAULT INTERRUPTER
HIGH INTERRUPTING CAPACITY
GP
GRC
HACR
HH
GRD
GPM
H
HD
GRS
HIC
HG
HAND HOLE
HIGH
HEAVY DUTY
MERCURY
GFP
GFCI
GC
GALV
GFI
GND
GEN
GAL
GA
G
GALVANIZED
GROUND
GALLON
GROUND
GAUGE
AMPEREA
AMERICAN NATIONAL STANDARDS INSTITUTE
AMPERE FUSE; AMPERE FRAME
AUTOMATIC TRANSFER SWITCH
ABOVE FINISHED FLOOR
ALTERNATING CURRENT; ARMORED CABLE
AMPERE INTERRUPTING CAPACITY
AMERICAN WIRE GAUGE
ABOVE FINISHED GRADE
AMPERE TRIP
ASYMMETRICAL
AUXILIARY
AMPERE
ARCHITECT
AVERAGE
APPROXIMATE
ACCESS PANEL
ANSI
ASYM
AT
ATS
AUX
APPROX
AP
AMP
ARCH
AWG
AVG
ADJUSTABLE
AIR-CONDITIONING
ALUMINUM
ALUMINUM
ALTERNATE
AIR HANDLING UNIT
AF
A/C
AFF
ADJ
AC
ALT
AL
AIC
AHU
AFG
ALUM
F FUSED; FAHRENHEIT
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
FITTING; FOOTING
FULL LOAD AMPS
FULL VOLTAGE NON-REVERSING
FLUORINATED ETHYLENE PROPYLENE
FEET PER MINUTE
FUSED DISCONNECT
FREQUENCY MODULATION; FACTORY MUTUAL
FTG
FLA
FIXT
FPM
FM
FLR
FLUOR
FVNR
FURN
FT
FR
FIXTURE
FLOOR
FURNISHED
FOOT; FEET
FIRE RATING
FLUORESCENT
FACP
FAAP
FCU
FDR
FFEC
FC
FA
FIG
FIN
FEP
FD
FAN COIL UNIT
FEEDER
FOOT-CANDLE
FIRE ALARM
FIGURE
FINISHED
MANUFACTURINGMFG
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
MERCURY VAPOR, MEGAVOLT; MEDIUM VOLTAGE
NON-AUTOMATIC
NATIONAL ELECTRICAL CODE
NOT TO SCALE
NORMALLY CLOSED
ON CENTER; OVERCURRENT
OVERHEAD AND PROFIT
NUMBER; NORMALLY OPEN
NON-METALLIC SHEATHED CABLE
NON-FUSED DISCONNECT
NOT IN CONTRACT
OUTSIDE DIAMETER
OVERHEAD DOOR
OFFICE PRINCIPAL GROUND POINT
OVERHEAD DISTRIBUTION SYSTEM
NOT AVAILABLE; NOT APPLICABLE
NM
NTS
OC
OL
O&P
NO
OH
ODS
OD
OHD
OPGP
OVERLOAD
OVERHEAD
NA
NEC
NEMA
ND
NL
NC
N/A
NAT
NFD
NIC
NF
NORMAL DUTY
NIGHT LIGHT
NATURAL
NON-FUSED
MAIN LUG ONLY
MANUAL TRANSFER SWITCH
MAXIMUM OVERCURRENT PROTECTION
MANUFACTURER
MISCELLANEOUS
MINIMUM; MINUTE
NORTH; NEW; NEUTRAL
MEGAVOLT AMPERES
MULTI; MULTIPLY
MANHOLE; METAL HALIDE; MAN-HOUR
MEGAVOLT AMPERES REACTIVE
MALLEABLE IRON; MINERAL INSULATED
MOCP
MTG
MTS
MTD
MOG
MW
MVA
MV
MVAR
N
MULT
MOUNTING
MOGUL
MOUNTED
MEGAWATT
MIC
MLO
MH
MFR
MISC
MIN
MI
MHZ
MOBIL
MO
MICROPHONE
MEGAHERTZ
MOBILIZATION
MONTH
TELEPHONE TERMINAL BOARD
TRANSIENT VOLTAGE SURGE SUPPRESSOR
UNDER (CABINET OR COUNTER)
UNDERGROUND
UNLESS OTHERWISE INDICATED
UNDERVOLTAGE RELAY (RELEASE)
TRIGGER START
UNIT HEATER
VOLT AMPERES
VIDEO DISPLAY TERMINAL
VARIABLE AIR VOLUME
VOLT; VENTILATION
UNSHIELDED TWISTED PAIR
UNDERWRITERS LABORATORY
ULTRA HIGH FREQUENCY
UNDERGROUND FEEDER
VOLT-AMPERES REACTIVE
UL
UOI
UTIL
UVR
UNFIN
V
UTP
VDT
VAV
VAR
VA
UTILITY
UNFINISHED
TTB
TVSS
UC
UG
UF
TYP
TV
TS
UHF
UH
TYPICAL
TELEVISION
SOLENOID VALVE
SWITCHING DUTY
SYMMETRICAL
TIME CLOCK
TERMINAL BLOCK
TIME DELAY
TOTAL HARMONIC DISTORTION: THREAD
TOP OF FINISHED FLOOR
TAMPER RESISTANT
SQUARE YARD
SWITCHBOARD
TRANSFORMER
TEMPERATURE CONTROL CONTRACTOR
TETRAFLUOROETHYLENE
TEMPERATURE; TRANSFORMER
SUBCONTRACTORS
T
TB
TC
TD
THD
TELE
TFF
TR
TFMR
TFE
TH
TCC
TELEPHONE
THICK
SV
SWD
SYM
SWBRD
SW
SURF
SUBS
SYS
SYN
SY
SYNTHETIC
SYSTEM
SWITCH
SURFACE
METAL CLAD CABLE; MECHANICAL CONTRACTOR;
M THOUSAND; MATERIAL; MECHANICAL; METER
MOTOR CONTROLLER
MASTER ANTENNA TELEVISION
MOLDED CASE CIRCUIT BREAKER
MOTOR CONTROL CENTER
MAIN CIRCUIT BREAKER
MOTOR CIRCUIT SWITCH
MAIN DISTRIBUTION FRAME
MAIN DISTRIBUTION PANELBOARD
MINIMUM CIRCUIT AMPS
MAGNETIC STARTER
MOTOR CIRCUIT PROTECTOR
THOUSAND CIRCULAR MILS
MCA
MCB
MCCB
MCC
MDP
MDF
MCS
MCP
MCM
MED
MECH MECHANICAL
MEDIUM
MAN
MATV
MA
MAG STR
MAINT
MACH
MC
MAX
MAT
MANUAL
MAINTENANCE
MACHINE
MILLIAMPERE
MAXIMUM
MATERIAL
S SOUTH
SERVICE RACEWAY; SURFACE RACEWAY
SLIM LINE; SERVICE LATERAL
SOLID NEUTRAL
SECONDARY
SUPPLY FAN; SQUARE FOOT
SERVICE DROP
SHORT CIRCUIT RATING
SQUARE INCH
SQUARE FOOT
START/STOP
STEEL: SHUNT TRIP; SINGLE THROW
SINGLE POLE
STAINLESS STEEL; SAFETY SWITCH
SINGLE POLE, SINGLE THROW
SINGLE POLE, DOUBLE THROW
SERVICE ENTRANCE; SERVICE EQUIPMENT
STRUCTURAL
SPKR SPEAKER
STRUCT
SQ
SR
SPST
SQ IN
SQ FT
STR
STD
SS
S/S
ST
SQUARE
STARTER
STANDARD
SD
SCR
SCHED
SL
SN
SF
SEC
SE
SPDT
SP
SCHEDULE
SWITCH, THREE WAY
SWITCH LEG
SWITCH, DIMMER
SWITCH, WEATHERPROOF
SWITCH, WITH PILOT LIGHT
SWITCH, KEY OPERATED
SWITCH, FOUR WAY
3-WAY
SWITCH LEG
1
a 1
'F1'
SURFACE RACEWAY ("WIREMOLD")
UNDERFLOOR DUCT & JUNCTION BOX, DUAL SYSTEM
UNDERFLOOR DUCT & JUNCTION BOX, TRIPLE SYSTEM
UNDERFLOOR DUCT & JUNCTION BOX, SINGLE SYSTEM
CONDUIT, CAPPED
CONDUIT, TURNING DOWN
CONDUIT, TURNING UP
CONDUIT, EXPOSED
CONDUIT, BELOW FLOOR
CONDUIT, IN WALL OR CEILING
PANEL, FLUSH
DUPLEX RECEPTACLE
GROUND FAULT CIRCUIT INTERRUPTER/WEATHERPROOF ROOF
GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE
ISOLATED GROUND DUPLEX RECEPTACLE
DOUBLE DUPLEX (QUAD) RECEPTACLE
SINGLE RECEPTACLE
SWITCH, DOUBLE POLE
SWITCH, SINGLE POLE
SPECIAL OUTLET OR EQUIPMENT CONNECTION (AS NOTED)
FLOOR OUTLET
DUPLEX RECEPTACLE
PULL BOX
JUNCTION BOX
LIGHT FIXTURE TYPE
DOUBLE DUPLEX (QUAD) GROUND FAULT CIRCUIT
INTERRUPTER RECEPTACLE
CIRCUIT NUMBER
CIRCUIT NUMBER
MULTI-TECHNOLOGY CEILING OCCUPANCY SENSING
LIGHT, CEILING
LIGHT, CEILING
LIGHT, WALL
EXIT LIGHT, CEILING
EXIT LIGHT, WALL
EXIT LIGHT WITH DIRECTIONAL ARROW, CEILING
EXIT LIGHT WITH DIRECTIONAL ARROW, WALL
EMERGENCY LIGHTING UNIT
TRACK LIGHT FIXTURE
NIGHT LIGHT WITH 'NL' SUBSCRIPT
EMERGENCY LIGHT
ULTRASONIC CEILING OCCUPANCY SENSING
PASSIVE INFRARED CEILING OCCUPANCY SENSING
SINGLE POLE WALL OCCUPANCY SENSOR
TWO POLE WALL OCCUPANCY SENSOR
PANEL, SURFACE
CONTROL PANEL (AS NOTED), FLUSH
CONTROL PANEL (AS NOTED), SURFACE
SURGE PROTECTIVE DEVICESPD
SCCR SHORT-CIRCUIT CURRENT-RATING
A1 A1-1
CIRCUIT NUMBER
PANEL NAME
PANEL NAME
* INDIVIDUAL CIRCUITS
NUMBERS ARE LOCATED AT
EACH DEVICE
NEUTRAL CONDUCTOR
PHASE (OR CONTROL) CONDUCTOR
GROUND CONDUCTOR
ISOLATED GROUND CONDUCTOR
INDICATES MINIMUM WIRE SIZE PER SPECIFICATIONS
S1
S2
MT
PI
US
ISOLATED GROUND DOUBLE DUPLEX (QUAD) RECEPTACLE
WP
J
P
F
F
F
F
DH
F
D
H
FS
TS
VCC
VOICE COMMAND CENTER
DC
KP
PIR
C
VIDEO SURVEILLANCE CAMERA (CEILING)C
INTERCOM CALL SWITCH
WALL MOUNTED SPEAKER (ROUND)
BUZZER
WALL MOUNTED SPEAKER (SQUARE)
CEILING MOUNTED SPEAKER (ROUND)
MICROPHONE OUTLET
SPEAKER VOLUME CONTROL
BELL
CEILING MOUNTED SPEAKER (SQUARE)
HORN-PAGING
S
S
V
M
P
S
S
CLOCK (WALL)
CLOCK (CEILING)
PUSHBUTTON
UP/DOWN PUSHBUTTON
UP/DOWN/STOP PUSHBUTTON
1-PHASE MOTOR
3-PHASE MOTOR
DISCONNECT
MANUAL MOTOR STARTER
MANUAL MOTOR STARTER WITH PILOT SWITCH
MAGNETIC MOTOR STARTER
COMBINATION DISCONNECT & MAGNETIC MOTOR STARTER
P
SMALL TRANSFORMER
TIMECLOCK
PHOTOCELL
TC
PC
R
LC
RELAY PANEL
LIGHTING CONTACTOR
HORN
ELECTRICAL GROUND
DROP CORD (AS NOTED)
POWER POLE
FFIRE ALARM STROBE (CEILING MOUNTED)
EMERGENCY VOICE-ALARM LOUDSPEAKERA
CARD READERCR
ELECTRIC LATCHEL
POWER SUPPLYPS
CONTROL PANELCP
SWITCH, SPRING WOUND, INTERVAL TIME SWITCH
1. COORDINATE LOCATIONS OF ALL DEVICES TO BE INSTALLED IN CEILINGS
(LIGHTS, SPEAKERS, DETECTORS, ETC.) WITH THE ARCHITECTURAL
REFLECTED CEILING PLANS.
2. NOTIFY ENGINEER OF ANY CONFLICTS PRIOR TO INSTALLATION.
3. ALL 120 VOLT CIRCUITS SHALL UTILIZE SEPARATE INDEPENDENT NEUTRAL
CONDUCTORS. DO NOT SHARE NEUTRALS.
4. CONTRACTOR SHALL COORDINATE WITH ALL TRADES. NO ADDITIONAL
COMPENSATION WILL BE ALLOWED FOR INCORRECT WORK, OR FOR
INFRINGEMENT UPON OTHERS WORK, DUE TO A LACK OF COORDINATION.
5. DEVICES IN GENERAL SHALL BE CENTERED IN WALL SPACE IN WHICH THEY ARE
INSTALLED OR THEY SHALL BE SPACED SYMMETRICALLY (FOR EXAMPLE, CENTER
DEVICES WHEN MOUNTED ON FACE OF COLUMNS).
6. COORDINATE & VERIFY LOCATIONS OF DEVICES W/ BLOCK COURSING, FINISH
MATERIALS, CASEWORK, ETC. PRIOR TO ROUGH-IN.
7. WIRING TO ALL RECEPTACLES ON DEDICATED CIRCUITS SHALL BE #10 MINIMUM
UNLESS OTHERWISE NOTED.
8. ALL WIRING SHALL BE MINIMUM #12 AWG. IN 3/4" CONDUIT UNLESS OTHERWISE
NOTED OR REQUIRED.
9. CONTRACTOR SHALL COORDINATE OCCUPANCY SENSOR LOCATIONS AND
ARRANGE FOR BEST OPERATION. COMMISSION AND COORDINATE SENSOR
OPERATIONAL SETTINGS WITH OWNER DURING INSTALLATION. AT COMPLETION
OF PROJECT AND AFTER OWNER OCCUPANCY, CONTRACTOR SHALL MAKE ONE
READJUSTMENT PER SENSOR AS DIRECTED BY THE OWNER.
10. COORDINATE EXACT LOCATION OF ALL DEVICES, AND DEVICE/COVER COLORS,
WITH ARCHITECT PRIOR TO ROUGH-IN.
11. PROVIDE ACCESS PANELS AS REQUIRED TO SERVICE PULL/JUNCTION BOXES
CONCEALED IN WALLS OR CEILINGS. COORDINATE LOCATIONS WITH
ARCHITECT/ENGINEER.
12. PROVIDE EXTENSION RING ON EXISTING DEVICE BOXES TO ACCOMODATE NEW
WALL FINISHES AS REQUIRED.
VOICE/DATA/COAX (RF) OUTLET (ONE CAT. 6A VOICE/ONE CAT. 6A DATA/ONE RG-6 COAX - JACKS AND CABLES)
VOICE/DATA OUTLET (ONE CAT. 6A VOICE/ONE CAT. 6A DATA - JACKS AND CABLES)
SINGLE OR SPECIAL OUTLET AS INDICATED (V=CAT. 6A VOICE; D=CAT. 6A DATA; C=RG-6 COAX), EXAMPLE:
WALL PHONE OUTLET (ONE CAT. 6A VOICE - JACK AND CABLE)W
D =ONE CAT. 6A DATA - JACK AND CABLE
VOICE/DATA/DATA/COAX (RF) OUTLET (ONE CAT. 6A VOICE/TWO CAT. 6A DATA/ONE RG-6 COAX - JACKS AND CABLES)2D
WIRELESS ACCESS CONNECTION POINT (TWO CAT. 6A DATA - JACKS AND CABLES) - PROVIDE 10'-0" SERVICE LOOP AND RED RJ45 JACKS ABOVE CEILING. AP
NOTE: COLOR OF DATA JACKS SHALL MATCH WIRING DEVICES, AP JACKS SHALL BE RED AND PHONE JACKS SHALL BE BLUE, UNLESS OTHERWISE DIRECTED.
EMERGENCY WALL PHONE OUTLET (ONE CAT. 6A VOICE - JACK AND CABLE)911
DATA/DATA/COAX (RF) OUTLET (TWO CAT. 6A DATA/ONE RG-6 COAX - JACKS AND CABLES)D
TELEVISION OUTLET (ONE CAT. 6A DATA/ONE RG-6 COAX - JACK AND CABLE) - VERIFY EXACT OUTLET (& DUPLEX RECEPT.) LOCATION WITH OWNER.TV
EMERGENCY NOTIFICATION SYSTEM WALL OUTLET (ONE CAT. 6A DATA - JACK AND CABLE)ENS
CIRCUIT NUMBER:
PANEL - CIRCUIT NUMBER
(I.E. A1-1)
MULTIPLE INDIVIDUAL CIRCUIT NUMBERS:
PANEL - CIRCUIT NUMBER, CIRCUIT NUMBER, CIRCUIT NUMBER
(I.E. A1-1,3,5)
2-POLE CIRCUIT NUMBER
PANEL - CIRCUIT NUMBER/CIRCUIT NUMBER
(I.E. A1-1/3)
3-POLE CIRCUIT NUMBER
PANEL - CIRCUIT NUMBER/CIRCUIT NUMBER/CIRCUIT NUMBER
(I.E. A1-1/3/5)
PROJECTOR (SEE A/V SPECS)
PR
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
DATAD
VOICEV
FIBERF
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
NORTH
PARTIAL FIRST FLOOR PLAN - LIGHTING DEMOLITION
SCALE: 1/4" = 1'-0"
GENERAL NOTES
1. SEE DRAWING E001.
2. SEE DRAWING E201 FOR NEW WORK.
3. EXISTING DOWN LIGHTS IN CONFERENCE ROOM 101E ARE 120V
QUARTZ FIXTURES AND ARE FED FROM EXISTING LUTRON
DIMMING PANEL LOCATED IN BACK OF CLASSROOM 105. EXISTING
LIGHTS IN REMAINDER OF PROJECT AREA ARE 277V AND FED FROM
EXISTING PANEL '1H1'.
4. EXISTING EXIT LIGHTS AND NIGHT LIGHTS ARE 277V AND ARE
FED FROM EXISTING EMERGENCY PANEL ' HE1'.
5. Z# INDICATED AT LIGHT FIXTURE IS DIMMING SYSTEM ZONE
NUMBER PER ORIGINAL DRAWINGS. VERIFY IN FIELD.
FOR REFERENCE ONLY.
6. SEE DRAWING E401 FOR EXISTING PANEL LOCATIONS.
PLAN NOTES
1REMOVE TRACK LIGHTS AND TRACK IN ITS ENTIRETY. PATCH WALLS.
REMOVE SWITCH 'a' THAT CONTROLLED TRACK LIGHT IN ROOM 101.
SWITCH 'b' TO REMAIN.
REMOVE LIGHT FIXTURES AND PREPARE EXISTING LIGHTING CIRCUIT FOR
REUSE.
REMOVE WALL MOUNT OCCUPANCY SENSOR / SWITCH AND WIRING.
REMOVE EXIT LIGHT AND PREPARE EXISTING EMERGENCY CIRCUIT FOR
REUSE.
REMOVE LIGHT FIXTURE AND PREPARE EXISTING EMERGENCY
CIRCUIT FOR REUSE.
REMOVE LIGHT SWITCH AND WALL MOUNTED LIGHT.
REMOVE LIGHT FIXTURES AND WIRING TO EXISTING LUTRON DIMMING
PANEL IN BACK ROOM OF CLASSROOM 105.
REMOVE LUTRON GRAPHIC EYE CONTROL STATION AND WIRING TO
EXISTING LUTRON DIMMING PANEL IN BACK ROOM OF CLASSROOM 105.
PATCH WALL OR PROVIDE BLANK COVER.
REMOVE LUTRON SCENE CONTROL STATION AND WIRING TO EXISTING
LUTRON DIMMING PANEL IN BACK ROOM OF CLASSROOM 105.
PATCH WALL OR PROVIDE BLANK COVER.
REMOVE EMERGENCY LIGHT FIXTURE AND WIRING TO EXISTING LUTRON
DIMMING PANEL IN BACK ROOM OF CLASSROOM 105.
BASE BID = NO WORK IN THIS ROOM; EXISTING LIGHTING TO REMAIN.
ALTERNATE #1 = PERFORM WORK AS SHOWN (PLAN NOTE 3).
REMOVE LIGHT SWITCH AND WIRING. PREPARE BOX FOR REUSE.
BASE BID = NO WORK IN THIS CORRIDOR; EXISTING LIGHTING TO REMAIN.
ALTERNATE #3 = PERFORM WORK AS SHOWN.
2
3
4
5
6
EXISTING WORK TO
BE REMOVED
EXISTING WORK
TO REMAIN
DEMOLITION LEGEND
7
8
9
10
11
9
10
11
11
CEILING = 10' - 1 1/2"
8
666
CEILING = 9' - 0"
CEILING = 10' - 0"
CEILING = 9' - 0" (VERIFY)
CEILING = 9' - 0"
CEILING = 9' - 0"
3
3
3
3
7
3
BULKHEAD = 8' - 8"
CEILING = 9' - 8"
5
1
1
2
S1
4
TYPICAL BULKHEAD
= 9' - 11 1/2"
12
12
13
13
13
13
13
13
EXISTING PANEL '1L3'
120/208V (POWER)
14
14
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
NORTH
PARTIAL FIRST FLOOR PLAN - POWER / SYSTEMS DEMOLITION
SCALE: 1/4" = 1'-0"
GENERAL NOTES
PLAN NOTES
1ACCESS CONTROLS TO REMAIN.
REMOVE ALL AV EQUIPMENT COMPLETE. TURN OVER TO OWNER.
REMOVE FIRE ALARM DEVICES AND PREPARE FOR REUSE.
REMOVE TELECOM DEVICE AND PREPARE FOR REUSE.
REMOVE RECEPTACLE AND PREPARE WIRING FOR REUSE.
REMOVE CONNECTION TO EWC AND PREPARE WIRING FOR REUSE.
CABLE TRAY ABOVE CEILING TO REMAIN.
REMOVE SPEAKER, WALL JACK AND WIRING. TURN SPEAKER OVER TO
OWNER.
MOTORIZED WALL AND CONTROLS TO REMAIN AND BE DISABLED IN
PLACE.
PROJECTION SCREEN AND WIRING TO REMAIN AND BE DISABLED IN
PLACE.
REMOVE PROJECTOR AND WIRING COMPLETE. TURN OVER TO OWNER.
REMOVE ACCESS POINT AND PREPARE FOR REUSE.
PROJECTION SCREEN CONTROL AND WIRING TO REMAIN AND BE
DISABLED IN PLACE.
BASE BID = NO WORK IN THIS CORRIDOR CEILING, EXISTING TO REMAIN.
ALTERNATE #3 = PERFORM WORK AS INDICATED.
REWORK EXISTING RECEPTACLE AS REQUIRED FOR WALL REWORK.
REMOVE TELECOM DEVICES AND CABLING.
2
3
4
5
6
EXISTING WORK TO
BE REMOVED
EXISTING WORK
TO REMAIN
DEMOLITION LEGEND
7
8
9
10
11
12
13
ACCESS PANEL E.
ACCESS PANEL E.
ACCESS PANEL E.
PROJECTOR SCREEN E.
IN BULKHEAD
HOLE IN WALL
S
S
PR
AP
F F
1. SEE DRAWING E001 FOR ADDITIONAL GENERAL NOTES.
2. SEE DRAWING E211 FOR NEW WORK.
3. SEE DRAWING E401 FOR EXISTING PANEL AND TELECOM ROOM
LOCATIONS.
13
8
9
10
2
8
1D/1V/1C/1F
1D/1V/1C/1F
1D/1V/1C/1F
12
11
1
1D/1V/1C
3
1D/1V/1F
5
6
7
1D/1V/1F
1D/1V/1F
1D/1V
5
3
4
1D/1V/1C
1D/1V/1C
1
5
16
4
5
EXISTING PANEL '1L3'
120/208V (POWER)
14
14
15
16
15
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
NORTH
PARTIAL FIRST FLOOR PLAN - LIGHTING
SCALE: 1/4" = 1'-0"
GENERAL NOTES
1. SEE DRAWING E001 FOR ADDITIONAL GENERAL NOTES.
2. SEE DRAWING E401 FOR EXISTING PANEL LOCATIONS.
EMERGENCY LIGHTING IS FED FROM EXISTING PANEL 'HE1' IN
LOWER LEVEL (NOT SHOWN).
PLAN NOTES
1CONNECT LIGHT TO EXISTING EMERGENCY LIGHTING CIRCUIT.
EXTEND EXISTING 277V LIGHTING CIRCUIT FROM ADJACENT AREA.
CONNECT TO EXISTING 277V LIGHTING WITHIN THE AREA.
PROVIDE 0-10V DIMMER, LIKE LEVITON RENOIR II.
BASE BID = NO WORK IN THIS ROOM; EXISTING LIGHTING TO REMAIN.
ALTERNATE #1 = PERFORM WORK AS SHOWN (EXCEPT
REPLACE/PROVIDE 3-WAY SWITCHES AND WIRE AS REQUIRED)..
PROVIDE NEW DEVICE IN EXISTING BOX AND PROVIDE WIRING.
BASE BID = NO WORK IN CORRIDOR; EXISTING LIGHTING TO REMAIN.
ALTERNATE #3 = PERFORM WORK AS SHOWN.
2
3
4
RENOVATION LEGEND
WORK TO BE INSTALLED.
EXISTING WORK TO REMAIN.
'A' 'A'
MT
3
4
MT
1
1
4
1
'A' 'A'
MT
4
3
1 1
3
'A' 'A' 'A'
3
4
MT
4
4
4
MT
2
MT
2
CEILING = 10' - 1 1/2"
CEILING = 9' - 0"
CEILING = 10' - 0"
CEILING = 9' - 0"
CEILING = 9' - 0"
BULKHEAD = 8' - 8"
TYPICAL BULKHEAD
= 9' - 11 1/2"
CEILING = 10' - 1 1/2"
CEILING = 9' - 0"
3
1
LIGHTING FIXTURE SCHEDULE
MARK
FIXTURE
MOUNTING
'A'
IN GRID
DESCRIPTION
LED 277V
2'X4' ARCHITECTURAL TROFFER, ANGLED LENS, DIFFUSE
CENTER OPTIC, 0-10V DIMMING, HIGH OUTPUT, WHITE
FINISH, 10-YEAR WARRANTY.
FINELITE HPR-LED-A-2X4-DCO-H-835-120V-SC-C1
RECESSED
LAMP
41
LOAD (VA)
TEMP.TYPE LUMENS
3500K 5416
'B'LED 277V
6-INCH DOWNLIGHT, 0-10V DIMMING, 45-DEGREE
DISTRIBUTION, CLEAR REFLECTOR, SELF-FLANGED,
5-YEAR WARRANTY.
PRESCOLITE #LF6SL-6LFSL1500-35K-B24
19 3500K 1500RECESSED
'X'LED UNV
LED EXIT SIGN WITH BLACK DIE CAST ALUMINUM
HOUSING, BRUSHED ALUMINUM FACE, AC ONLY,
CEILING MOUNT, RED LETTERS, UNIVERSAL
VOLTAGE, SINGLE FACE.
PRESCOLITE # SE-S-R-BN
2 RED
-
UNIVERSAL
VOLTAGE
(VERIFY)
5
5
1
EXISTING PANEL '1L3'
120/208V (POWER)
6
6
6
6
6
4
7
7
MTMT
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
NORTH
PARTIAL FIRST FLOOR PLAN - POWER / SYSTEMS
SCALE: 1/4" = 1'-0"
GENERAL NOTES
1. SEE DRAWING E001 FOR ADDITIONAL GENERAL NOTES.
2. SEE DRAWING E401 FOR EXISTING PANEL AND TELECOM ROOM
LOCATIONS.
PLAN NOTES
1PROVIDE RECEPTACLE AND CONNECT TO EXISTING RECEPTACLE
CIRCUIT WITHIN THE ROOM.
RELOCATE EXISTING TELECOM DEVICES AND CABLES.
PROVIDE RECEPTACLE AND CONNECT TO EXISTING EWC CIRCUIT.
EXISTING PANEL '1L3', 225A, 120/208V, 3Ø. CUTLER-HAMMER PRL2.
THIS PANEL SERVES EXISTING DEVICES IN THE PROJECT AREA.
REINSTALL EXISTING FIRE ALARM DEVICE. EXTEND EXISTING
WIRING.
PROVIDE FIRE ALARM DEVICE TO MATCH EXISTING. CONNECT TO
EXISTING WIRING.
CONNECT RECEPTACLE TO EXISTING SPARE BREAKER 33 IN
EXISTING PANEL '1L3'.
PROVIDE CAT. 6A DATA JACKS WITH HOMERUN CABLES TO EXISTING
TELECOM ROOM.
COORDINATE MOUNTING HEIGHT WITH TV. CONTRACTOR TO INSTALL
OWNER PROVIDED TV, MOUNTING BRACKET, SOLSTICE AND SOUND
BAR.
COORDINATE MOUNTING HEIGHT WITH TV.
CONNECT RECEPTACLE TO EXISTING SPARE BREAKER 35 IN
EXISTING PANEL '1L3'.
PROVIDE 120V CIRCUIT TO NEW VAV BOX. CONNECT TO EXISTING
SPARE BREAKER 37 IN EXISTING PANEL '1L3'.
BASE BID = NO WORK IN THIS CORRIDOR CEILING, EXISTING TO
REMAIN.
ALTERNATE #3 = PERFORM WORK AS SHOWN.
ALL WORK AND EQUIPMENT ASSOCIATED WITH AV SYSTEM IN
CONFERENCE 120 SHALL BE PROVIDED AND INSTALLED UNDER
ALTERNATE #2. POWER AND ROUGH-INS SHALL BE BASE BID.
REINSTALL EXISTING WIRELESS ACCESS POINT. REWORK AS
REQUIRED.
PROVIDE CEILING MIC AND SPEAKERS FOR AV. SEE E401.
(ALTERNATE #2).
PROVIDE 75" TV, MOUNT AND PTZ CAMERA FOR AV. SEE E401.
(ALTERNATE #2).
PROVIDE WALL CABINET FOR AV EQUIPMENT. PROVIDE EXTRON
WALL CONTROLLER AND AMPLIFIER. PROVIDE SOLSTICE POD.
PROVIDE HDMI INPUT WALL PLATE. PROVIDE NETWORK SWITCH.
SEE E401. (ALTERNATE #2).
2
3
4
5
7
8
9
10
11
12
RENOVATION LEGEND
WORK TO BE INSTALLED.
EXISTING WORK TO REMAIN.
1D/1V/1C/1F
1D/1V/1C/1F
1D/1V/1C/1F
1D/1V/1C
1D/1V/1F
1D/1V/1F
1D/1V/1F
1D/1V/1C
1D/1V/1C
F
1
2
1D/1V2
1
1
1
1
3
1 1
1D
1D
4
F
5
5
6
6
2D
7
11
8
8
9
8
11
10
12
EXISTING PANEL '1L3'
120/208V (POWER)
13
13
14
14
AP
15
15
16
17
18
16
17
18
Facilities M
anagem
ent D
epartm
ent
951 S
ycam
ore S
treet
Terre H
aute, Indiana 47809
Phone: (812) 237-8100 F
ax: (812) 237-7630
NORTH
FIRST FLOOR PLAN
SCALE: 1/16" = 1'-0"
PROJECT AREAEXISTING TELECOM ROOM.
PROVIDE ALL WORK AS REQUIRED.
EXISTING PANEL '1H1'
277/480V (LIGHTING)
EXISTING LUTRON DIMMING PANEL
120/208V (LIGHTING)
EXISTING PANEL '1L3'
120/208V (POWER)
THERE IS A SEPARATE RENOVATION PROJECT OCCURRING IN ROOM
105 THAT INVOLVES THE EXISTING LUTRON DIMMING PANEL.
COORDINATE WORK AND SCHEDULING WITH THAT CONTRACTOR.
CONFERENCE 120 AV REQUIREMENTS
NOTE:
ALL WORK AND EQUIPMENT ASSOCIATED WITH AV SYSTEM FOR
CONFERENCE 120 SHALL BE PERFORMED UNDER ALTERNATE #2.
POWER AND ROUGH-INS SHALL BE INSTALLED UNDER BASE BID.