a-2...a-4.1 1 grease int. trash bin 2' - 6" 3' - 6" 3' - 9" 6' -...
TRANSCRIPT
DN
356 SF
DINING
01
93 SF
COLD BOX
03
339 SF
KITCHEN
04
369 SF
SCULLERY
05
EMPLOYEE
RESTROOM
06
OFFICE
08
TRASH AREA
07
189 SF
MENS
RESTROOM
14
189 SF
WOMENS
RESTROOM
13
523 SF
BREWERY
10
306 SF
COLD BOX
09
558 SF
BAR
12
142 SF
SERVICE
COUNTER
02
1
A
C
D
20
' -
5"
45
' -
5"
B
19' -
8"
B
N
S
B1
A-5.1
C1
A-5.1
D1
A-5.1
D01
D02D03
D04
D05
D06
D07D08
D09
D10
D11
D12
W03
W01
W01
W01
W01W01W01
W02
A1
A-5.1
A-4.1
1
GREASE INT.
TRASH BIN
2' - 6" 3' - 6"
3' - 9"
6' - 3"
2' - 8"
5' -
0"
7 BBL KETTLE /
WHIRLPOOL
7 BBL
COMBI-TANK
7 BBL FV FERMENTATION
7 BBL FV FERMENTATION
7 BBL BBT
7 BBL BBT
D17
D13
D14
D15
D16
W04
W04
2' - 6"
1 34
A
C
D
B
GREASE INT.
TRASH BIN
35' - 5" 55' - 10"
20
' -
5"
45
' -
5"
19
' -
8"
92' - 0"
86' -
2 1
/2"
24' - 2"4' - 8"
9' -
3"
6' - 10" 3"
8' - 2" 4' - 8"
5' - 2" 3' - 0" 9' - 4" 3' - 0" 20' - 2"
1' - 6"
6' - 0"
1' - 6"
6' - 2"
1' - 8"4' - 0"6"6"4' - 0"4' - 0"
2' - 0"
5' -
1"
4' -
11"
8' -
10"
5' -
4"
12' -
0"
3' -
9"
6' -
0"
3' -
9"
12' -
0"
4' -
0"
12' -
0"
7' -
0"
9"
3' - 0" 12' - 4" 3' - 0" 5' - 8" 6' - 0" 4' - 7"
19
' -
1 1
/2"
5' -
1"
18' -
11"
1' -
10"
4' -
0"
2' -
0"
4' -
0"
2' -
0"
4' -
0"
1' -
10"
7' - 11" 7' - 5"
9' - 6" 9' - 6"
1
1
6
1
1
1
4
34
55
5
5
4
5
1
4
4
3
27' - 0"4 1/2"
4 1/2"
4"
4 1
/2"
20' -
4 1
/2"
4 1/2"
56' - 2 1/2"
5
4"4 1
/2"
4 1/2"4 1/2"
36' - 2"
4
5' -
1"
2' -
8"
5' -
0"
1' -
1"
4
4
523 SF
BREWERY
10
DINING
01
KITCHEN
04
SCULLERY
05
FERMENTATION
11
MENS
RESTROOM
14
WOMENS
RESTROOM
13
4
BAR
12
OFFICE
08
EMPLOYEE
RESTROOM
06
4
COLD BOX
03
40" HIGH
COLD BOX
09
6' - 7"8' - 6"
5' -
2"
8' -
8"
1' - 0"
BY MANUF.
1
1
2
3
4
5
WALL TYPE 1
WALL TYPE 2
WALL TYPE 3
WALL TYPE 4
WALL TYPE 5101
1t
1i
Room name
101ROOM TAG, SEE FINISH SCHEDULE SHEET A-7.1
WALL TAG, SEE SHEET A-6.1 FOR WALL TYPES DETAIL
WINDOW TAG, SEE WINDOW SCHEDULE SHEET A-7.1
DOOR TAG, SEE DOOR SCHEDULE SHEET A-7.1
NEW WALL
No. C-34408
LIC
ENSED A RCHIT ECT
STA
T E OF CA L IFO
R
NIA
REUBEN GENEWALTERS
RENEWAL DATE3/31/2019
A
1 2 3 4 5
B
C
D
A
B
C
D
1 2 3 4 5
PROJECT NAME:
DATE ISSUED:
PROJECT NUMBER:
NO.
SHEET TITLE:
SHEET NUMBER:
DRAWN BY:
DESCRIPTION DATE
PERMIT SUBMITTAL
24
2 E
ast
Com
mon
we
alth
, F
ulle
rton
, C
A 9
28
32
21705
BLDG. DEPT SUBMITTAL 05/14/2018
PROPOSED FLOOR& DIMENSION PLAN
A-2.1
PR
04/09/18
1/8"=1'SC:
SHEET NOTES KEYNOTES LEGEND
C1 1/8"=1'SC:
C3PROPOSED FLOOR PLAN PROPOSED DIMENSION PLAN
WALL TYPE
NORTHNORTH
1. REFER TO MEP. DRAWINGS FOR ADDITIONAL INFORMATION.2. REFER TO INTERIOR SCHEDULE FOR FINISH MATERIAL SPECIFICATIONS & REQUIREMENTS.3. IT IS THE CONTRACTORS RESPONSIBILITY TO LOCATE AND INSTALL & CONNECT ALL
MECHANICAL, ELECTRICAL AND MISCELLANEOUS EQUIPMENT AS REQUIRED TO COMPLETE THE WORK. REFER TO MEP & STRUCTURAL DWGS FOR ADDITIONAL INFORMATION.
4. ALL OPENING DIMENSIONS ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED.EXISTING DIMENSIONS AND CEILING HEIGHTS ARE FOR REFERENCE ONLY. VERIFY ALL DIMENSIONS IN FIELD.
5. YOU CAN FIND MORE INFORMATION AND DETAILS REGARDING ACCESSIBLE TOILET AT SHEET A-0.1.
6. ALL DECORATIVE MATERIALS AND TRIM SHALL COMPLY WITH THE PROVISIONS OF CBC 806.7. THERMAL AND ACOUSTIC INSULATION SHALL COMPLY WITH CBC 720.8. PATCH & REPAIR EXISTING CONSTRUCTION TO REMAIN THAT IS DAMAGED DURING DEMOLITION
AND CONSTRUCTION.9. ADJUST LOCATION OF EXISTING FIRE/LIFE SAFETY EQUIPMENT AS REQUIRED10. PROVIDE BLOCKING AS REQUIRED FOR ALL NEW INSTALLATIONS11. VERIFY POWER REQUIREMENTS FOR ALL FF&E, LIGHTING, AND EQUIPMENT PRIOR TO
INSTALLATION.12. ALL OTHER LOOSE ACCESSORIES NOT MENTIONED, GC TO REMOVE, TAG, SECURE, STORE AND
RE-INSTALL AT EXISTING LOCATION PER OWNER & OPERATOR DIRECTIONS, UNLESS NOTED OTHERWISE.
13. ALL SIGNAGE TO COMPLY WITH ADA ACCESSIBLE REQUIREMENTS. SEE SIGNAGE DETAILS. 14. FIRE DEPARTMENT FACILITY KEY LOCATION SHOULD BE APPROVED BY FIRE MARSHALLS PRIOR
TO INSTALLATION.15. MECHANICAL ROOMS, ELECTRICAL ROOMS & SERVICE AREAS OPENINGS INTO EXIT
PASSAGEWAYS SHALL BE SEPARATED BY MINIMUM 1 HOUR FIRE BARRIER WITH 1 HOUR DOOR TO COMPLY WITH CBC 402.8.7. CONTRACTORS MUST VERIFY WITH ARCHITECT PRIOR TO INSTALLATION.
1ELECTRICAL EQUIPMENT - SEE ELECTRICAL PLAN
MOP SINK - SEE PLUMBING PLANS
WALL MOUNTED AIR CURTAIN
30" X 48" CLEAR SPACE AT URINAL
30" X 48" CLEAR SPACE AT LAVATORY
5'-0" CLEAR TURNING RADIUS
SOLID SURFACE COUNTERTOP OVER MARINE GRADEPLYWOOD
34" ADA TRANSACTION TOP
LIQUOR LOCKUP
POINT OF SALE COMPUTER
TRENCH DRAIN (SEE PLUMBING PLANS)
FLOOR DRAIN (SEE PLUMBING PLANS)
BEER TANK (BY OTHERS)
FERMINTATION EQUIPMENT (BY OTHERS)
KETTLE (BY OTHERS)
OPERABLE BAR COUNTER
30"x48" CLEAR SPACE AT ACCESSIBLE COUNTER
KITCHEN HOOD TYPE 1 - SEE MECH. & KITCHEN PLANS
KITCHEN HOOD TYPE 2 - SEE MECH. & KITCHEN PLANS
2
3
4
5
6
1
1
2
3
4
4
7
8
9
10
2
5
5
6
1
7
TYP.
11
12
8
TYP.
9
10
1
13
11
14
12
13
15
14
16
15
17
16
18
19
30X48
30X4830X48
17
20
18
19
TYP.
TYP.
TYP.
FIRST FLOOR
PLAN
0' - 0"
T.O.P
16' - 6"
ACD B
T.O.T
21' - 4"
11'
- 0
"
16'
- 6
"
7' -
0"
6"
1' -
6"
2' -
10"
5' -
0"
4' - 0"
ADJACENT STRUCTURE
NOT A PART
FIRST FLOOR
PLAN
0' - 0"
T.O.P
16' - 6"
1 3 4
ROOF PLAN
13' - 0"
T.O.T
21' - 4"
6"
1' -
6"
ALLEY
7' -
0"
8' -
0"
HD
R.
11'
- 0
"
3' -
6"
2' -
9"
TH
K. 8
"
20' -
0" T
.O. S
CR
EE
N
FIRST FLOOR
PLAN
0' - 0"
T.O.P
16' - 6"
A C DB
ROOF PLAN
13' - 0"
16'
- 6
"
12'
- 0
"
13'
- 8
"
ADJACENT STRUCTURE
NOT A PART
4"
8' -
0"
FIRST FLOOR
PLAN
0' - 0"
T.O.P
16' - 6"
134
ROOF PLAN
13' - 0"A-3.2
C1-3
BUILDING SILHOUETTE
IN FOREGROUND
BUILDING SILHOUETTE
IN FOREGROUND
13'
- 1
0"
CANOPY
16' - 0"
14'
- 0
"2' -
0"
FIRST FLOOR
PLAN
0' - 0"
13'
- 1
0" A
PP
RO
X.
CANOPY
16' - 0"
No. C-34408
LIC
ENSED A RCHIT ECT
STA
T E OF CA L IFO
R
NIA
REUBEN GENEWALTERS
RENEWAL DATE3/31/2019
A
1 2 3 4 5
B
C
D
A
B
C
D
1 2 3 4 5
PROJECT NAME:
DATE ISSUED:
PROJECT NUMBER:
NO.
SHEET TITLE:
SHEET NUMBER:
DRAWN BY:
DESCRIPTION DATE
PERMIT SUBMITTAL
24
2 E
ast
Com
mon
we
alth
,
Fullert
on
, C
A 9
28
32
21705
BLDG. DEPT SUBMITTAL 05/14/2018
EXTERIOR
ELEVATIONS
A-3.1
PR
04/09/18
NORTH ELEVATION 1/8"=1'SC:
C1
1/8"=1'SC:
B1
1/8"=1'SC:
A1
1/8"=1'SC:
WEST ELEVATION
SOUTHELEVATION
EAST ELEVATION
SHEET NOTES KEYNOTES LEGEND
C3
B4
A4
CANOPY NORTH/SOUTH ELEVATION
CANOPY EAST/WEST ELEVATION
1/8"=1'SC:
1/8"=1'SC:
1 DOOR - PER SCHEDULE
WINDOW - PER SCHEDULE
BUILDING BEYOND - SHADED
CONCRETE BLOCK WALL - UNFINISHED
ROOF OVERFLOW OPENING
CANOPY COLUMNS TO REMAIN
PARAPET CAP FLASHING
WALL MOUNTED SIGNAGE - SEPARATE PERMIT
CANOPY MOUNTED SIGNAGE - SEPARATE PERMIT
SHEET METAL MECHANICAL ROOF SCREEN - PAINTED
POWER POLE - EXISTING
WALL MOUNTED EXTERIOR LIGHTING - SEE ELECTRICAL PLANS
SHEET METAL ROOF DRAIN PIPE - PAINTED
THRU WALL SCUPPER
CONCRETE FILLED PIPE BOLLARD
BIKE RACK
CANOPY BEYOND
WOOD FENCE WITH DOOR
STEEL TRELLIS - SEE STRUCTURAL
TRELLIS MOUNTED SIGNAGE - UNDER SEPARATE PERMIT
EXISTING STEEL CANOPY TO REMAIN
2
1
1
3
4
5
6
2 3
4 TYP.
TYP. TYP.
7
8
9
6 TYP.
8
7
9
10
11
12
13
10
11 TYP.
12
12
14
13
TYP.
14
10
TYP.
3
15
15
15
16
216
2
13 TYP.
411TYP.
17
517 TYP.
14
TYP.
3
TYP.
5 17
13
TYP.
18
18 18
18
19
20
21
20
1
22
19
19
19
19
1
FIRST FLOORPLAN0' - 0"
T.O.P16' - 6"
ACD B
ROOF PLAN13' - 0"
A-3.2
C1-2
T.O.T21' - 4"
11' -
0"
CANOPY16' - 0"
6"
1' -
6"
+0"-56'-2 1/2"-14'-4"
16' -
6"
16' -
0"
6' -
1"
FIRST FLOORPLAN0' - 0"
T.O.P16' - 6"
1 3 4
ROOF PLAN13' - 0"
A-3.2
C1-1
T.O.T21' - 4"6"
1' -
6"
5' -
9"
6' -
1"
4' -
0"
5' -
6" No. C-34408
LIC
ENSED A RCHIT ECT
STA
T E OF CA L IFO
R
NIA
REUBEN GENEWALTERS
RENEWAL DATE3/31/2019
A
1 2 3 4 5
B
C
D
A
B
C
D
1 2 3 4 5
PROJECT NAME:
DATE ISSUED:
PROJECT NUMBER:
NO.
SHEET TITLE:
SHEET NUMBER:
DRAWN BY:
DESCRIPTION DATE
PERMIT SUBMITTAL
24
2 E
ast
Com
mon
we
alth
, F
ulle
rton
, C
A 9
28
32
21705
BLDG. DEPT SUBMITTAL 05/14/2018
EXTERIORELEVATIONS
A-3.2
PR
04/09/18
1/8"=1'SC:
C1
1/8"=1'SC:
B1
1/8"=1'SC:
A1
SHEET NOTES KEYNOTES LEGEND
FENCE ELEVATIONS
OVERALL EAST ELEVATION (STREET VIEW)
OVERALL SOUTH ELEVATION (STREET VIEW)
2 EAST ELEVATION
1 SOUTH ELEVATION
3 NORTH ELEVATION
1 DOOR - PER SCHEDULE
WINDOW - PER SCHEDULE
BUILDING BEYOND - SHADED
CONCRETE BLOCK WALL - UNFINISHED
ROOF OVERFLOW OPENING
CANOPY COLUMNS TO REMAIN
PARAPET CAP FLASHING
WALL MOUNTED SIGNAGE - SEPARATE PERMIT
CANOPY MOUNTED SIGNAGE - SEPARATE PERMIT
SHEET METAL MECHANICAL ROOF SCREEN - PAINTED
POWER POLE - EXISTING
WALL MOUNTED EXTERIOR LIGHTING - SEE ELECTRICAL PLANS
SHEET METAL ROOF DRAIN PIPE - PAINTED
THRU WALL SCUPPER
CONCRETE FILLED PIPE BOLLARD
BIKE RACK
CANOPY BEYOND
WOOD FENCE WITH DOOR
STEEL TRELLIS - SEE STRUCTURAL
TRELLIS MOUNTED SIGNAGE - UNDER SEPARATE PERMIT
EXISTING STEEL CANOPY TO REMAIN
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
1
12
3 TYP.
3
TYP.
4
14
13
TYP.
10
18
18
12
1211
TYP.
11
TYP.
20
21
2021
21
2121
20
FIRST FLOOR
PLAN
0' - 0"
CEILING
12' - 0"
T.O.P
16' - 6"
1 3 4
T.O.T
21' - 4"
COLD BOX
09
12'
- 0
"
11'
- 0
"
BAR
12
OPEN TO
SCULLERY
10'
- 0
"
16'
- 6
"3' -
6"
20'
- 0
"
FIRST FLOOR
PLAN
0' - 0"
CEILING
12' - 0"
T.O.P
16' - 6"
A C DB
COLD BOX
09
BREWERY
10
MENS
RESTROOM
14
EMPLOYEE
RESTROOM
OFFICE 7 BBL FV
FERMENTATION
7 BBL FV
FERMENTATION
7 BBL BBT
FIRST FLOOR
PLAN
0' - 0"
CEILING
12' - 0"
T.O.P
16' - 6"
CD B
12'
- 0
"
SCULLERY
05
OPEN TO BREWERY
CEIL
10' - 0"7 BBL
COMBI-TANK
7 BBL KETTLE /
WHIRLPOOL
FIRST FLOOR
PLAN
0' - 0"
CEILING
12' - 0"
T.O.P
16' - 6"
1 3 4
FACE OF BLDG. BEYOND
DINING
01KITCHEN
04
SCULLERY
05
COLD BOX
03
SERVICE
COUNTER
02
UTILITY ENCLOSURE12'
- 0
"
11'
- 9
"
CEIL
10' - 0"16'
- 6
"3' -
6"
20'
- 0
"
No. C-34408
LIC
ENSED A RCHIT ECT
STA
T E OF CA L IFO
R
NIA
REUBEN GENEWALTERS
RENEWAL DATE3/31/2019
A
1 2 3 4 5
B
C
D
A
B
C
D
1 2 3 4 5
PROJECT NAME:
DATE ISSUED:
PROJECT NUMBER:
NO.
SHEET TITLE:
SHEET NUMBER:
DRAWN BY:
DESCRIPTION DATE
PERMIT SUBMITTAL
24
2 E
ast
Com
mon
we
alth
,
Fullert
on
, C
A 9
28
32
21705
BLDG. DEPT SUBMITTAL 05/14/2018
SECTIONS
A-5.1
AD
04/09/18
1/8"=1'SC:
C1
1/8"=1'SC:
B1
1/8"=1'SC:
A1
1/8"=1'SC:
C3
SHEET NOTES KEYNOTES LEGEND
SECTION 3 SECTION 4
SECTION 2
SECTION 1
1 ROUTE DUCT TO EXHAUST FAN - SEE MECHANICAL PLANS
WALL MOUNTED AIR CURTAIN - SEE MECHANICAL & ELECTRICAL PLANS
WALL MOUNTED SIGNAGE - PROVIDE J-BOX
ADJACENT STRUCTURE - NOT A PART
STEEL TRELLIS
SHEET METAL DRAIN LEADER BEYOND
ROOF OVERFLOW SCUPPER BEYOND
THRU WALL ROOF SCUPPER
BUILDING SIGNAGE - BY OTHERS
BAR COUNTER - BY OWNER
SUSPENDED CEILING GRID - VINYL FACED
CMU WALL AT PROPERTY LINE - SEE STRUCTURAL
1-HR STUCCO SOFFIT CEIL. OVER EXTERIOR COVERED ENCLOSURE
INTERIOR LIGHTING - SEE RCP AND ELECTRICAL LIGHTING PLAN
CONDENSATE HOOD - SEE MECHANICAL & KITCHEN PLANS
RATED EXHAUST HOOD - SEE MECHANCAL PLANS
CONCRETE FOOTING - SEE STRUCTURE
CONCRETE SLAB - SEE STRUCTURE
SHEET METAL MECHANICAL SCREEN WALL - PAINTED
KITCHEN HOOD - BY OTHERS
ROOF JOISTS - SEE STRUCTURAL
THICKEN SLAB UNDER BREWERY EQUIPMENT
AIR HANDLING UNIT - SEE MECHANICAL
BREWERY EQUIPMENT - BY OTHERS UNDER SEPARATE PERMIT
METAL RESTROOM PARTITIONS
CEILING JOISTS - SEE STRUCTURAL
BACK COUNTER AT BAR AREA
HARD LID GYPSUM BOARD CEILING
WINDOW BEYOND
2
OPEN TO BAROPEN TO SCULLERY
3
4
5
5
6
7
8
8 8
7 3
1 12TYP.6 6
9
10
11
12
9
13
14
15
13 10 10
14
12
1 12 TYP.
2
TYP.
2
1 18TYP. 11
15
15
15 BEYOND
15
BUILDING SILHOUETTE BEYONDBUILDING SILHOUETTE BEYOND
1
1
3
8
16
17
18
4
11
16
171817
19
195
20
20
20
13 13
12
21
21
5
22
22
22
12
20
2121
FENCE BEYOND
5 12
6
14
23
23
10
10
ALLEY
5 5
10
24
24 TYP. 24
TYP.
24
TYP.
24
TYP.
FENCE
3 7 7
6
3
25
25
777
26
26
27
27
28
28
3 7 7
7BBL BBT 7BBL BBT 7BBL BBT 7BBL BBT
29
29